Loading...
APPROVED Architectural_Plan+6.9.2022PROJECT INFORMATION: PROJECT CONTACT: Selena Fitch Fitch Design Company 425-481-8190 Selena@FitchDesignCompany.com OWNER: Beauchene Jason D & Holly L 9508 231st PI. SW Edmonds, WA, 98020 PARCEL NUMBER: 00596600000300 ZONING: RA2.5 JURISDICTION: EDMONDS SCOPE OF WORK: INTERIOR REMODEL OF KITCHEN c C VICINITY MAP: 9508 231ST PI SW The following documentation shall be available on site for the building inspector: ■ - ■,� COE APPROVED ARCHITECTURAL PLAN SET ® COE APPROVED STRUCTURAL PLAN SET COE REVIEWED CALCULATION PACKET ■ ENERGY CREDIT WORKSHEET - ❑ SITE PLAN ■ ■ CIVIL PLAN .F] F] ■ ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 GENERAL NOTES: 1. All work to comply with 2018 International Building Code and 2018 international Residential Code with local amendments. 2. Verify all dimensions and field conditions before beginning work and notify designer of any discrepancies. 3. Provide solid wood blocking for support at all wall mounted fixtures. 4. Provide approved draftstopping in concealed space between ceiling and floor; and approved firestopping in walls per code. 5. Flash all openings with minimum 26 gauge steel (galvanized or factory finish). 6. All wood in contact with concrete or masonry to be pressure treated. LIFE SAFETY NOTES: 1. Stairways to meet minimum requirements of 2018 IRC R311.7; - Minimum stair width: 36" - Minimum headroom: 80" - Maximum riser height: 7 3/4" - Minimum tread depth: 10" - Rise or run dimensions shall not vary more than 3/8" - Minimum landing length: 36" - Handrail height: 34-38" above stair nosing 2. Stairways with four or more risers shall have a handrail. 3. Handrails shall be continuous and terminate at a wall or newel post. 4. Guards shall be provided for porches, balconies or raised floor surfaces located more than 30" above the floor or grade below. 5. Guards shall be 36" in height and designed to resist a 200 IN concentrated load on the top rail and 50 psf on all guardrail infill components. 6. Required guards shall have a maximum opening such that a 4" diameter sphere can not pass through. 7. All new smoke and carbon monoxide detectors to be hardwired with a battery back-up. 35'-6 1/8" EXISTING BASEMENT FLOORPLAN N SCALE: 1/4" = V-0" ENERGY NOTES: 1. All new fenestration U-values and insulation R-values shall satisfy the prescriptive path of the 2018 Washington State Energy Code. 2. Prescriptive Requirements (Climate zone 4C); - Vertical glazing: U = 0.30 - Overhead glazing: U = 0.50 - Doors: U = 0.20 - Ceilings: R-49 - Single rafter ceilings: R-38 - Walls (above grade): R-21 (w/ headers insulated R-10) - Walls (below grade): 10/15/21 int +TB - Floors: R-30 - Slab on grade: R-10 (24" perimeter) 3. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation shall not be less than specified above. 4. Builder shall complete and post an insulation "Certificate for Residential Construction" within three feet of the electrical panel prior to final inspection. 5. Blower door testing: air leakage shall not exceed three air changes per hour. A written report of blower door test results shall be signed by the testing party and provided to the building inspector prior to call for final inspection. 6. A minimum of 75% of permanantly installed lamps in lighting fixtures shall be high efficacy lamps. 7. Kitchen, Bathroom and Laundry exhaust fans shall terminate outdoors and not in attics, soffits, ridge vents or crawl spaces. 8. A whole house mechanical ventilation system shall be designed in accordance with IRC section M1507.3. The ventilation system shall provide outdoor air at a rate not less than specified in tables M1507.3.3(1) or MlS07.3.3(2). EXISTING SECOND FLOORPLAN SCALE: 1/4" = P-0" EXISTING FIRST FLOORPLAN 38'-11/8" 1 01T A Tr 26'-5 1/2" v," 0STAIN ELECTRICAL PERMIT FROM .ABOR at WALL LEGEND — NEW FRAMED WALLS 0 EXISTING WALLS REMOVE EXISTING I IIY Y �1.� [17.�►[I]I Y x.9 ® DIMENSIONS ARE FROM FINISHED DRYWALL TO FINISHED DRYWALL, UNLESS NOTED OTHERWISE ® ALL DRAWINGS & NOTES CROSS-REFERENCE EACH OTHER. SEE SPECIFICATION SHEETS FOR ADDITIONAL SPEC'D PRODUCT INFORMATION. ® CABINET DETAILS & DIMENSIONS ARE SUBJECT TO VARIATION BASED ON ON -SITE FRAMING & CABINET MANUFACTURER & MAY VARY FROM DRAWINGS. ® CABINET SUPPLIER TO VERIFY ACTUAL THICKNESS OF SELECTED SLAB COUNTERTOPS IN RELATION TO CABINET HEIGHTS, ADJUST AS NEEDED (SELECTIONS MAY VARY FROM DRAWINGS & SPECS) ® RECOMMENDATION: A CABINET CONTROL SAMPLE SHOULD BE SEEN AND APPROVED BY CLIENT PRIOR TO CABINET ORDER ® ALL NATURAL STONE (TILE & SLABS) CAN VARY FROM SAMPLES USED IN THE DESIGN PROCESS. IT IS STRONGLY RECOMMENDED THAT CLIENTS SEE AND APPROVE ACTUAL SLABS PRIOR TO FABRICATION. ® TILE LAYOUTS CAN VARY FROM DRAWINGS BASED ON ON -SITE CONDITIONS ® FIELD VERIFY ALL SHWR PLUMBING HEIGHTS & BATHROOM ACCESSORY LOCATIONS W/ HOMEOWNER PRIOR TO INSTALLATION PAGE REFERENCE: IA 1- EXISTING FLOORPLAN IA 2- NEW FLOORPLAN BJECT 1 V FICLU INSPECTION FOR CODE COMPLIANCE iTRIE� APPROVED PLANS MUST BE ON JOB SITE See separate structural plans City Of Edmonds Building Department Work KITCHEN REMODEL o w 0 Address 95o8 231ST PL SW U Ln W Owner BEAUCHENE Approved Date 06/16/2022 Building Official EricI C4*q2r Permit Number BLD2022-0724 Separate plumbing permit required. Mechanical has not been included on this permit. )ISCLOSURE: & SIZE DESIGNATIONS GIVEN VERIFICATION ON JOBSITE & TO FIT UNFORESEEN JOB CONDITIONS. DESIGN PLANS ARE NOT PROVIDED FOR ARCHITECTURAL OR ENGINEERING USE. RECEIVED Jun 09 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIXED SCALE 1 TO 1 IN FT. Z V LJ Z Q a a 20 V" LL E DATE: 6/3/2022 JOB NO. 551 ALL DIMENSIONS & SIZE DESIGNATIONS GIVEN ARE SUBJECT TO VERIFICATION ON JOBSITE & ADJUSTMENT TO FIT UNFORESEEN JOB CONDITIONS. DESIGN PLANS ARE NOT PROVIDED FOR ARCHITECTURAL OR ENGINEERING USE. 26-5 1/2" Z 3'-5 1/4" 3'-4 1/2" 9' 1" WALL LEGEND V 35'-6 1/8" 16'-0" 91/4" 41/2" W — NEW FRAMED WALLS Q 21'41 1/4" 8 7/8" 12'-10" EXISTING WALLS T REMOVE EXISTING y V H LL Ln M � N M N INTERIOR NOTES � N � N 4 ® DIMENSIONS ARE FROM FINISHED DRYWALL TO FINISHED DRYWALL, UNLESS NOTED OTHERWISE 00 GARAGE OFFICE cq p,® ALL DRAWINGS & NOTES CLG HT: T10" CLG HT: T10" cn - CROSS-REFERENCE EACH OTHER. SEE O NEW DROPPED BEAM PER n1 SPECIFICATION SHEETS FOR ADDITIONAL \ ENGINEERING O SPEC'D PRODUCT INFORMATION. \ CABINET DETAILS & DIMENSIONS ARE 'A co SUBJECT TO VARIATION BASED ON ON -SITE FRAMING & CABINET / r MANUFACTURER & MAY VARY FROM E 0 0 0 0 DRAWINGS. c\ .O 110CFM _ CABINET SUPPLIER TO VERIFY ACTUAL THICKNESS OF SELECTED SLAB _ COUNTERTOPS IN RELATION TO CABINET E 0 N OO ch HEIGHTS, ADJUST AS NEEDED U N \ N KITCHEN (SELECTIONS DRAWINGS &SPECS)RY FROM p�jp 00 CLG HT: T9 a" f7. G 1n N = _ RECOMMENDATION: A CABINET �p 1.n AO - CONTROL SAMPLE SHOULD BE SEEN AND+�, cV N — 0? r + APPROVED BY CLIENT PRIOR TO CABINET z oq W co BATHROOM 00 N ORDER r. c \ N N ® ALL NATURAL STONE (TILE & SLABS) CAN w :) cu N LG HT: T10" M VARY FROM SAMPLES USED IN THE A cn cn dN - DESIGN PROCESS. IT IS STRONGLY W110CFM N ,� LIVING ROOM RECOMMENDED THAT CLIENTS SEE AND CLG HT: T10" 'i APPROVE ACTUAL SLABS PRIOR TO DATE: ? FABRICATION. � 6/3/2022 p EXISTING BEAM TILE LAYOUTS CAN VARY FROM DRAWINGS BASED ON ON -SITE JOB NO. o CONDITIONS 551 DEN00, � N t� ®FIELD VERIFY ALL SHWR PLUMBING CLG HT: T10" LAUNDRY � - HEIGHTS & BATHROOM ACCESSORY CLG HT: T10" SMOKE DETECTORS CONNECTED DECK LOCATIONS W/ HOMEOWNER PRIOR TO CLG HT: 11' jLG HT: 10' PER CODE INSTALLATION CLG HT: T10" � ®110CFM PAGE REFERENCE: d IA 1- EXISTING FLOORPLAN .� DINING ROOM IA 2- NEW FLOORPLAN CLG HT: T10" - N o M N 41/4" 51/2° 41/2" 18'-1 3/8" 3'-5 1/4" 2' 6" 3'-3" 5'-3" 7'-4 3/4" 5'-10 1/2" 3'-7 1/2" 8 3/4" 5 1/2" 26'-2 3/4" 35'-6 1/8" EXISTING FIRST FLOORPLAN SCALE: 1/4" = 1'-0" 38'-1 1/8" EXISTING BASEMENT FLOORPLAN N SCALE: 1/4" = 1'-0" 13'-8 3/4" '_2" 2'-10 1/2" '_3" 3'-0" 2'-10 1/2" 51/8" '-1" 71/4" 1 r-I BATHROOM #2 BATHROO M MASTER CLG HT: T10" G HT: 7'10" BEDROOM ®110CFM 11°CFM CLG HT: T10" U Q O ai u 00 � O CC O W d" Ca i W d z L0 2 N cn rl SKYU N N T Q � - N f �\ � N O a-i KIDS ROOM L — —1 N ' \ CLG ll') HT: ' O i lJ7 co RECEIVED z N Jun 09 2022 a o0 CITY OF EDMONDS CV DEVELOPMENT SERVICES DEPARTMENT O W FIXED SCALE 1 TO 1 IN FT. 15'-7" 3'-101/2" '_2" 3'-51/4" 12'-11" �81 4" 38'-0" EXISTING SECOND FLOORPLAN SCALE: 1/4" = 1'-0" ALL DIMENSIONS &SIZE DESIGNATIONS GIVEN ARE SUBJECT TO VERIFICATION ON JOBSITE & ADJUSTMENT TO FIT UNFORESEEN JOB CONDITIONS. DESIGN PLANS ARE NOT PROVIDED FOR ARCHITECTURAL OR ENGINEERING USE. N t\ �7� � N CLG HT: 71 °�� N c-I O i 11') N O �--� c-1 N c-1 \ V � N N N � � \ t\ � N OFFICE CLG HT: T10" _ N \ 0 \ M