FIR2021-0064+Calculations+6.23.2021_8.35.44_AM+2264740State of Washington Sprinkler License # Designer: Kenneth H. Robinsoninn RO-BI-NP-*272C2, Level 3 Robinson-Elmslie 29330124th Ave N.E. State of Washington Sprinkler Inc 01403�-7462WA 98223 Designer, Plumbing ompetancy #7659 0106-CE Level Builder: G2 Contractors Property address: 15712 72nd Ave W, Edmonds (Sharma Residence) Total quantity of sprinkler heads: 52 Fire sprinkler system notes: * Fire sprinkler system design per NFPA 13d (standard for houses and duplexes). * Fire sprinkler system to be pressure tested and flow tested. * Sprinkler piping and fittings to be C.P.V.C. "Flameguard" by Speers Mfg. * Installation of C.P.V.C. pipe and fittings to be done by manufacturer certified installers. * Underground water service to be combination fire and domestic. Backflow assembly to be installed on fire sprinkler supply after tee. * Sprinkler heads to be Globe Sprinkler Co. "Inch" concealed pendant with escutcheons per listing. SIN # GL4906 and Globe GL4231 horizontal sidewall . * Lines in attic to be protected from freezing with tent insulation (by others). * Design spacing for Globe concealed pendant is 16' x 16' (256 square feet). * Design Density is minimum .05 gpm/square foot * Design area is for 2 head simultaneous flow. * Minimum flow requirements (concealed pendant) are: (1) head flow =13 gpm @ 7.0 psi (flat or sloped ceilings) (2) head flow =13 gpm (ea) @ 7.0 psi (flat or sloped ceilings) JOB: G2 CONTRACTORS (SHARMA RESIDENCE) ADDRESS: 15712 72ND AVE W, EDMONDS DESIGNER: KENNETH H. ROBINSON-ELMSLIE CALCULATIONS FOR 26 GPM FLOW (2 HEADS) IND. LOSS NET TOTAL A. WATER PRESSURE IN STREET 130.00 B: SELECT PIPE SIZE: 1" C: DEDUCT METER & SETTER LOSS (1") 12.00 118.00 DEDUCT BACKFLOW DEVICE LOSS 5.00 113.00 D: DEDUCT HEAD LOSS FOR ELEVATION HEIGHT 30 20 13.02 99.98 E. DEDUCT PRESSURE LOSS FROM MAIN TO SRINKLER 1-1/4" WATER SERVICE ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 150 1 150 ELLS: 2 2 4 R-TEES 4 3 12 B-TEES 1 2 2 TOTAL: 168 TOTAL EQUIVALENT FT. X .04 PSI/FT = 6.72 93.26 F: DEDUCT PRESSURE LOSSES FOR 1-1/2" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 0 1 0 ELLS: 0 7 0 R-TEES 0 1 0 B-TEES 0 8 0 TOTAL: 0 0 TOTAL EQUIVALENT FT. X .0178 PSI/FT = 0 93.26 F: DEDUCT PRESSURE LOSSES FOR 1-1/4" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 10 1 10 ELLS: 2 6 12 R-TEES 4 1 4 B-TEES 1 6 6 TOTAL: 32 TOTAL EQUIVALENT FT. X .0343 PSI/FT = 1.0976 92.16 F: DEDUCT PRESSURE LOSSES FOR 1" PIPING FROM CONTROL VALVE TO MOST REMOTE SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 127 1 127 ELLS: 10 5 50 R-TEES 13 1 13 i..................� ... . B-TEES 4 5 20 20 WASHIINGTON STATE • TOTAL: 2 • CERTIFICATE OF COMPETENCY • TOTAL EQUIVALENT FT. X .1067 PSI/FT = 22.41 69.76 : FIRE PROTECTION SPRINKLER SYSTEMS F: DEDUCT PRESSURE LOSSES FOR 314" PIPING ; Kenneth H. Robinson-Eimslie FROM CONTROL VALVE TO MOST REMOTE SPRINKLER • 765"1WCE Level 3 • ITEM QUANTITY EQUIV FT. TOTAL FT. • Robinson Plumbing, in . M• PIPE: 17 1 17 :'R 81 P 72C2 � of ELLS: 2 4 8 • ; Expi es R-TEES 0 1 0 93 • _� 1213!(21 B-TEES 0 3 0 •w •. s ............. ... t TOTAL: 25 TOTAL EQUIVALENT FT. X .0893 PSI/FT = 2.23 67.52 REMAINING PRESSURE FOR SPRINKLER OPERATION 67.52 CALCULATIONS PER NFPA 13D A.10.4.3 (A) (2013 ED.)