Loading...
APPROVED FIR2022-0093+Fire_Sprinkler_Plan+9.7.2022_10.59.23_AM+3093774CUppFNT 5fATIC WAV, PpF55UPF 5TAfIC; 75 P51 511? E I.FV- too' MINIMUM 4" WAT P, MAIN (�'7 100 �XV'IOp WALL G �L�v-1oo' 4' OP 150' OP III COPP�P' 31`51 �055 FLOWING 266PM I I PFX WAT 5FP,,,.V CF P TA L V5 X III III I � I m-4 II I DIAIINb �( I- II III _ 5*60 p�L1ABL� Model LL-pPC30pPC30 Concealed pendent Sprinkler I8 Istri" 21 2ndF� O- - - 26 K-3, 155P-, 3/811 Orifice, Maximum 5pacinq 12'xI2' IT ��M-12 5prinkler head demand; 9 qpm @ 9 39 TOM, I -I / 2" AQUAP�X TO 5Y5T�M I\�LIA131L� Model LL-pPC49pPC49 Concealed pendent Sprinkler -- MINIMUM 3/ 411 5Y5T�M O K=4"9, 155P-,1/ 1611 Orifice, Maximum 5pacinq 16'xl6' PPAIN 5prinkler head demand; 13 qpm @ 7,04 TO PLUMBING PIXTUII�5 NOT 0 - - - Gj I\�LIA131L� Model LL-pPC49pPC49 Concealed Pendent Sprinkler K=4,9, 155P-,1/ 1611 Orifice, Maximum 5pacinq 18'xl8' SHOWN ON 519I?INKLFPI LOOP UTC49-15 5prinkler head demand; 17 qpm @ 12,0� L PULL POP\T f\�LIA131L� Model LL-PI-P,49P1-p49 Pecessed Pendent 5prinkler 0BALL VALVE K=4'9, 175F-,1/ 16'' Orifice, Maximum 5pa6inq 16'x16' Fl-FV=04' 5prinkler head demand; 13 qpm @ 7,04 M05f HYPPAULICALLY P�MOT H�AP5 HIV # GPM PpF551jp� AT 5Tp��f I NFAn N'14 17 53'81 2 N�AI2 N,7 & N,I 18 54 / DOUBLE IDED O`L ZERO GLEAR,AN(-_E k DIRECT P' VENT W lye �A5 Ei fZ - AGE I W I jII 17 LITN 12 I - --- - X� / \ I d) Mpll V�L CONNFCION5 I I I I I I I I I I IIIII III n ill GA pFE III II - . iiI I � II � i � I • / 1 OPNG. ABV. 4X10 RJaIR 5 „ OPRAILIN G �i III SS IL n - `� -- -- F 0zll mi(�l�I ryl N N I SELF ry+h lk HEAT FV PI^4" a HEAT A6 FOYER 1 DETEGnKTO �I VAULTED Ozo 4 Q 9'18 n ui 0 18" FLOOR TRUSSES ® 24" O.G.Q I I — — UNLE55 OTHERJNI5E NOTED m WQ CGARAGE m GONG _LINE OF O.H- DOOR IN UPRIGHT P051TION--� I AI I 1 LINE OF O.H. OR C'IRDER d IN UPRIGHT 1;051TIO � I RnER TRUSS I 8080 O.H. I �, „�� SV�A sfoQJF �q Svl IJ ` i 5 GAFZACGE DOOR 1 VA VF I 160 O .H. & RA E DO R MA H F L 00P,,� 11111100)11_ 1-011 F 12 TILE 1 fi C4f9-Jib 54 x&O' YVER I NEN +" f2" 18"x�qq.. 70 GRYVL.' 15 GE 5 I 8 DOOR III III >7EN III GA PEP2 T Tfzup C�IRI7 R - III _—s— III �p�C�O-12 UTM_12 I I N,2 N, B�DRoo>!4 7PET (:2) ;2X S 5 -s E3I -FOLD BEDROOM SOUR CARPET Not / 4" AQUAPFX FPOM 51 fO MAN 5FPNUP\ LOOP MULTIPUPT05� rIr� 5MINUP. 5Y5fM • 5PP\IWL�P 5Y5f�M TO BF IN5TALL�19 IN COMBINATION WITH TNT COLD 51►2 OF TNT 120M�5flC POfABL� WAV, 5Y5T�M, • 5PP\IWLI�p 5Y5T�M PF516N�19 TO TNT 2016 �PIVON OF TNF NPPA 13n 5TAN►2Ap12, • TH15 %665T�12 LAYOUT 15 BA51�12 UPON INPOP\MATION PP\OVlnFn BY OTNFp5, CHANGF5 IN CON5TPUCTION 01? PIFLb CONnITION5 MAY OCCUR, MICH MAY p�QUIP\� CHANGF5 TO TNT LAYOUT, If 15 TNT I?F5PON5IVILITY OF TNT IN5TALL�1? TO NOTIFY A-P�X P�516N 51�pVIC�5 OF 5UCH CHAN61�5, CO�OI?/ �INFTYP� LF6rNb BLUF LIN�5- FFE) TO FIXTUI?�5 C BATN, 5HOMP\, FTC), BLACK LINF5- 5P1?IWLI�I? H�Al2 TO 5PP\INKLFp H�AR i - 1 / 211 PIPS 51Z� I11 PIPS 51Z� i - 1-1 / 411 PIPS 51ZF NPPA 13V TVLF 25TANa5 TOM NEAT 50UI?a5 I CONa&A P APAMP, FITTING MOUNTING bMI1L. N,rs OP,PINAPY INTFPMFPIAt NFAf 50UP\C� TFMP, TAMr' P 9 1351-110, 115' -225' PpOP�X �P tF MINIMUM CUT L�NCITN 5M OF PIP�PUAC� 3611 1211 OF TUBING; �- 2" FPONT of �IPVLACF 6011 3611 MAXIMUM CUT L�%TH WOOb 13UpNIN6 5TOV� 4211 1211 OF TUBING; 1211 QTCH% PANC1 1811 911 WA1 ovf; 1811 911 NOT Alp U�5 1811 911 UNIN51ATEP H�Af PUCT5 1811 911 PPIOPFX PIp� UNIN5UUATEP NOT WAV, PIPF5 1211 61' SPINKL�p A►2APT�t? 5M OF NOT Alp 171FFU5�p 2411 1211 PpONT OF NOf Alp PIFFU5FP\ 3611 1811 FEILP V�pIPY PIN15H�p NOT WAT p NEAT p 611 311 OILING MAtPIAIL FTNACF 6" 311 TO n1�tpMIN� MOUNTING 50W-250W U16 f FIMPp 6" 311 H�16HT PftN5101\1 250W-499W UI61df FIXTUI?� 1211 611 Approved set of plans must be on site at the time of inspection. Failure to provide the approved set may result in a re -inspection fee. System drain(s) required at riser and must drain to the exterior. If riser is above lowest grade, 2nd drain required and signage at riser indicating location. Systems require signage IAW NFPA 13D. Coverage required to the following areas: I II Clothes closets, linen closets and pantries exceeding 24 square feet in area, with the smallest dimension greater II the 3- and having wall and ceiling surfaces of gypsum board. Bathrooms more than 55 square feet in area. When II fuel fired equipment is present on covered decks or porches, or living space above, at least one quick -response II intermediate temperature sprinkler shall be installed above the equipment or area under living space. I21 II II All fuel fired appliances, except attics if above all living areas. AoV b Fir " pRr 09/13/2022 AFM /,_/F�ttere►- 4"x(�O- P4 cJ. LJ 60" x 36 ------ TUB P IN PA .C�. I GL. T I _ nM I �- I 0 ' BEDROOM 68 LJ FAN N I tom TWO IL 24 f\�C�9'6 I ARPET V r a L I NEN ryT 40[ 8 STAIRCASE LUMINATION BI-COL)-% I NG A,T?S, 6 171 FZ AND O M TREADS F'ER I R305.6 54TALL ALL �yVTO YV/ YVD. P O 15ATH �YL 12 � ��� H�20 24 II 9-16 TUB/ShiOWEiz oR.O. = 5' 0-14" SEE NOTES 401 & T�7 H�4 H33 X -18 ��pPC3000 tvus 1 ��TM-12 pFC 0- 5 -2 Room — GARPET H59MH�38 '12 �� I � I ��pPC�O-12 z UPP p FLOOP\ 14 11 _ 1 -011 \ \ In \ d) 306 E3 I11,-22FOL 4 6" oW �DRooM N THREE G RPET I 2, AGN SERV 11112 47TH AVF W MUKILT�O, WA 98275 PH: 425-493-9680 PAX; 425-493-971 7 FMAIL; sal es@a-pexdesignservices com kF5112FNTIAL Plk� PI?OTCTION 5Y5T�M TUBE TYPE, 1 / 211 TO 1-1 / 211 AQUAP�X 5PP\INKL�k INPOI;MATION # OF N�A25 TH15 51j��f - 39 # OF N�A25 TH15 PP\01Cf - 39 5TAfIC PP�55Up� 15- 75 12�516N ONLY 5TAMP rwrr-�Mwwaw"www-www.w-www-. MIAa111NOTON STATE i CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS � E Libby Marie Babb i 3791-0722-A Level A-Pex Design Services, Inc, o APEXDDS782K5 ■ ■ i i M.0 maignatus .......... IN5f&LIN6 CONTFACTOP\ 5TAMP yyASMINGTON STATE ■ CERTIFICATE OF COMPETENCY ■ FIRE PROTECTION SPRINKLER SYSTEMS ■ Thomas Gill 7678-0409-A Level 1 O ■ Advanced Plumping II,LL ) ■ i ADVANP1838JO/ 1 ■ -r 4-L ■ ■ D�1-2 ■s rrrrrrrrrrrrrrrrrrrrrrrrrrrrri o 8008 203rd street sw Z RECEIVED Sep 07 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2022-0093 O l� V PPFLIM' & CON5f, 07-25-2022 2 3 N0, P�V150N/ 1551 17ATF, PpOJFCf #; 220125-21 COMPANY; APVANCFb PLUMBING CONTACT; 5OPFN BFLFW CONTACT PHONF # ; (425) 348-5100 5CA,L : 1 / 411 _ 11-011 PF516N�p BY; LFAN BOWMAN