Loading...
APPROVED ENG PLN BLD2022-1418+Site_Plan+10.18.2022_2.01.48_PM+3171439PROJECT INFORMATION Owner and address Scott and Kendra Anderson 1037 Glen St. Edmonds, 'WA 99020 Parcel iD#: OOS48900001602 Neighborhood: 160SO01 NE1/4 SEC24 T27N R3E Z_(f�)cv !�_s - PROJECT DESCRIPTION Demo existing deck and replace with 355 SF composite (deck CODES AND DESIGN LIVE LOADS All methods, materials and workmanship shall conform to the 2018 International Building Code (IBC) as amended and adopted by the local Building Department. Snow load: 25 psf Deck live load: 60 psf _Seismic Criteria: Assumed Soil Site Class D; Seismic Design Category D; Sds = 0.859; I = 1.0 FOUNDATION AND SOIL PRESSURE Presumptive vertical foundation pressure: 1,500 psf. STRUCTURAL REINFORCED CONCRETE Al! concrete shall meet the requirements of AC1-301, "Specifications For Structural Concrete For Buildings." Place concrete per AC1-304 and conform to AC1-306R for cold weather placement and AC1-305R for hot weather placement. Protect all concrete from premature drying, excessive hot or cold temperature. All concrete thicker or deeper than 4 inches shall be vibrated during placement. Use internal mechanical vibrators. Inserts, bolts, boxes, pipes, conduits, and other accessories shall be securely installed and inspected prior to placing concrete. Remove water, debris, wood, and loose concrete from space where concrete is to be placed. fc: 3,000 psi minimum at 28 days, 51✓2 sack minimum mix (special inspection is not required) Slump: 5 inches maximum water / cement: 0.47 maximum by weight air entrainment: 5% +/- 1 % 3/4-inch maximum size aggregate Cement: ASTM C 150, normal -Type I or ASTM C595, Type IL Coarse and fine aggregate: ASTM C33 Water shall be clean and not detrimental to concrete. Admixtures containing chlorides shall not be used. Do not use calcium chloride, fly ash and related materials. Reinforcing steel shall conform to ASTM A615 Grade 60 new billet stock, deformed steel free of rust, scale or other bond -reducing coatings. Tie bars securely with #16 double annealed wire. EPDXY FOR ANCHORS AND DOWELS Use Simpson SET-XP or Hilti HIT HY-20OR adhesive system. Follow manufacturer's instructions for all installation steps, including, injection tools, mixing nozzles, material handling and storing, substrate drilling and cleaning and adhesive injection. WOOD FRAMING AND LUMBER GRADING Allowable stress required shall be in accordance with standard grading rules of West Coast Lumber No. 16. Moisture content shall be maximum 19%. Wood framing details, not shown otherwise, shall be constructed to the minimum standards ofthe IBC and shall conform to Table 2304.10.1 Fastening Schedule of the IBC. Notations on drawings regarding connectors refer to products by the Simpson Tie Company Catalog C-C-2019. Where preservative treated lumber is cut or drilled after treatment) thecut surface shall be field treated with approved preservative by repeated brushingl dipping or soaking until the wood absorbs no more preservative. LOT COVERAGE CALCULATIONS Lest area: 13,650 square feet Structures House 1,396 sf Garage 375 sf Carport 312 sf 2,083 sf 2,083 sf/13,650 sf= 15% coverage Impermeable Surfaces House 1,396 sf Garage 375 sf Carport 31.2 sf Driveway 1,268 sf Walk/patio 1,239 sf Entry 65 sf 4,655 sf 4,655 sf/13,650 sf= 34% coverage OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE ENGINEERING DIVISION APPROVED. 10/25/2022 n4A9 I11l BLD2022-1418 AINSIDE OUT LIC#: INSIDOC886JR 4031168 TH St. SW Lynnwood, WA 98037 (206) 353-4937 APPROVED BY PLANNING Oct 24 2022 Zone RS-6 Corner Flag Setbacks: Required Actual Front 20' no change Sides 5' no change Rear 15' no change Other 25' 11' Height ',e.� RECEIVED Oct 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT