APPROVED BLD2022-1172+Architectural_Plan+9.1.2022_2.04.12_PM+3086606CODE: INTERNATIONAL BUILDING CODE (IBC) 2018 DIMENSIONAL LUMBER, ANCHOR BOLT AND NAILING SPECIFICATIONS PREPARED FOR SHARON STOCKER LOADINGS FLOOR LIVE LOAD ..................................................... 40 PSF DECK LIVE LOAD ..................................................... 60 PSF ROOF SNOW LOAD ..................................................... 25 PSF WIND CRITERIA BUILDING CLASSIFICATION ............................... 11 ULTIMATE WIND SPEED ...................................... 98 MPH WIND EXPOSURE ........................................... B TOPOGRAPHIC FACTOR, Kzt................. 1.0 SEISMIC CRITERIA SEISMIC RISK CATEGORY ............................... II SPECTRAL RESPONSE COEFFICIENT, Ss .... 1.30 SPECTRAL RESPONSE COEFFICIENT, S1 .... 0.50 SEISMIC SITE CLASS ................................. D SEISMIC DESIGN CATEGORY ............................... D STRUCTURAL DESCRIPTIONS REPLACEMENT OF EXISTING LOAD -BEARING WALL WITH NEW BEAM GENERAL CONDITIONS 1. THE CONTRACTOR SHALL EXAMINE THE STRUCTURAL DRAWINGS AND SHALL NOTIFY THE STRUCTURAL ENGINEER IN WRITING OF ANY DISCREPANCIES HE MAY FIND BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE STARTING WORK. 2. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER BEFORE PROCEEDING WITH ANY WORK SO INVOLVED. 3. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE THE NOTES, DRAWINGS, AND/OR SPECIFICATIONS DIFFER, THE MORE STRINGENT REQUIREMENT SHALL APPLY. 4. IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK, THE CONSTRUCTION SHALL BE THE SAME AS FOR SIMILAR WORK. 5. WORKING DIMENSIONS SHALL NOT BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THESE DRAWINGS. 6. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE STRUCTURAL ENGINEER OF ANY CONDITION THAT, IN HIS OPINION, MIGHT ENDANGER THE STABILITY OF THE STRUCTURE OR CAUSE DISTRESS TO THE STRUCTURE. 7. THE CONTRACTOR SHALL SUPERVISE AND DIRECT HIS WORK AND HE SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. 8. REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION NOT COVERED BY THESE GENERAL NOTES OR THE STRUCTURAL DRAWINGS. 9. ALL CONSTRUCTION SHALL BE DONE WITH MATERIALS, METHODS, AND WORKMANSHIP ACCEPTED AS GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY AND IN CONFORMANCE WITH THE PROVISIONS OF PREVAILING CODE EDITION OF THE "INTERNATIONAL BUILDING CODE" (IBC) AND STANDARDS REFERENCED THEREIN. 10. PIPES, DUCTS, SLEEVES, OPENINGS, POCKETS, CHASES, BLOCK -OUTS, ETC., SHALL NOT BE PLACED IN SLABS, FOUNDATIONS, ETC., NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR SUCH ITEMS, UNLESS SPECIFICALLY DETAILED ON THESE STRUCTURAL DRAWINGS. 11. ALTERNATE ASSEMBLIES AND MATERIALS WILL BE CONSIDERED FOR REVIEW. ENGINEER MAY REQUEST PAYMENT FOR REVIEW. FOUNDATION 1. STRUCTURAL DESIGN COMPLIES WITH SOILS REPORT PRODUCED BY: N.A. FOOTING BEARING PRESSURE: 1500 PSF (ASSUMED) 2 LATERAL EARTH PRESSURE ON RETAINING WALLS N.A. SUBGRADE PREPARATION, DRAINAGE PROVISIONS, AND OTHER RELEVANT SOIL CONSIDERATIONS ARE TO BE IN ACCORDANCE WITH SAID SOILS REPORT. STRUCTURAL AND MISCELLANEOUS STEEL 1. MEET REQUIREMENTS OF PS 20-70 AND NATIONAL GRADING RULES FOR SOFTWOOD DIMENSIONAL LUMBER. BEAR STAMP OF WWPA. 2. MINIMUM DIMENSIONAL LUMBER GRADES TO BE: WALL STUDS, 2X, 3 X........ WALL PLATES, 2X, 3X........ JOISTS, 2 X 6: ............. JOISTS, 2 X 8 AND UP....... BEAMS, HEADERS, 6X ........ BEAMS, HEADERS, 4X......... POSTS, 4X, 6X.............. LUMBER NOT NOTED HERE HF STUD GRADE HF STANDARD GRADE U.N.O HF #2 DF #2 DF #2 DF #2, WWPA GRADING DF #2 U.N.O DF #2 U.N.O 3. PROVIDE STANDARD CUT WASHERS FOR BOLT HEADS AND NUTS BEARING AGAINST WOOD. 4. ALL SILLS OR PLATES RESTING ON CONCRETE OR MASONRY THAT IS IN CONTACT WITH OR RESTING ON FOUNDATIONS SHALL BE PRESSURE -TREATED DOUGLAS FIR/ HEMFIR IN ACCORDANCE TO WITH AWPA U1 (PLANT/SHOP TREATMENT) AND M4 (FIELD TREATMENT) STANDARDS. ALL BEARING WALL PLATES SHALL HAVE 5/8" 0 x10" J-BOLTS PLACED AT MAXIMUM OF 9" FROM THE END OF A PLATE AND SPACED AT INTERVALS SHOWN ON THE SHEARWALL SCHEDULE (MAXIMUM 4'-0" OC SPACING). PROVIDE BP PLATE WASHER AT ALL FOUNDATION SILL PLATE ANCHOR BOLTS. PROVIDE TWO ANCHOR BOLTS MINIMUM PER SECTION OF SILL. FOR NON-SHEARWALL, PLACE ANCHORS AT 48". 5. BOLTS IN WOOD SHALL NOT BE LESS THAN 7 DIAMETERS FROM THE END AND 4 DIAMETERS FROM THE EDGE OF THE MEMBER. 6. NAILS: COMMON WIRE NAILS. NAILING IN ACCORDANCE WITH IBC TABLE 2304.9.1. 7. PRESSURE TREATED WOOD: ALL NAILS INTO PT WOOD SHALL BE HOT DIPPED GALVANIZED PER ASTM A153 OR STAINLESS STEEL. ALL METAL CONNECTORS IN CONTACT WITH PT WOOD SHALL BE HOT DIPPED GALVANIZED AND MEET ASTM A653 CLASS G185 (1.85 OZ OF ZINC PER SO FT MINIMUM) OR TYPE 304 / 316 STAINLESS STEEL SIMPSON Z-MAX CONNECTORS MEET THIS REQUIREMENT. FASTENERS AND CONNECTORS USED TOGETHER SHALL BE OF THE SAME TYPE (E.G. HOT DIPPED NAILS WITH HOT DIPPED HANGERS) 8. ALL LUMBER WITH A LEAST DIMENSION OF 2" (NOMINAL) SHALL BE STAMPED "SURFACE - DRY" AND SHALL HAVE A MOISTURE CONTENT WHEN SURFACED AND WHEN INSTALLED OF NO MORE THAN 19 PERCENT. LUMBER WITH A LEAST DIMENSION OF 4" (NOMINAL) OR GREATER SHALL BE STAMPED "SURFACE -GREEN" AND AIR-DRIED TO A MOISTURE CONTENT OF NOT MORE THAN 19 PERCENT PRIOR TO ITS USE IN FRAMING THE STRUCTURE. 9. NOTCHING AND BORING OF BEAMS AND JOISTS IS NOT ALLOWED WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD. CONCRETE AND REINFORCING 1. CONCRETE SHALL CONFORM TO THE INDICATED REFERENCE CODES AND STANDARDS EXCEPT AS MODIFIED BELOW: ACI-301 - "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE" ACI-318 - "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" ACI-305R - "HOT WEATHER CONCRETING" ACI-306R - "COLD WEATHER CONCRETING" ACI-304 - "GUIDE FOR MEASURING, MIXING, TRANSPORTING AND PLACING CONCRETE" 2. CONCRETE MIX SPECIFICATIONS LOCATION COMP. SRENGTH W/C RATIO AIR CONTENT REMARK City Of Edmonds Building Department Work KITCHEN REMODEL Address 110 5TH AVE S #401 Owner -- STOCKER ---------------------------------- ------------------------------------ Approved Date 9/15/2022 Building Official W. X CfALcLm Permit Number BLD2022-1172 ------------------------ ALL WORK SUBJECT APPROVED OBTAIN ELECTRICAL TO FIELD PERMIT FROM INSPECTION FOR PLANS MUST BE CODE COMPLIANCE ON JOB SITE STATE LABOR & INDUSTRIES I � This permit does not include Plumbing work to ibe done. Should Plumbing work be part of this remodel. Please obtain a Plumbing permit from ithe City of Edmonds. ■IN NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 NONE 0 ON; I FOOTING 3000 PSI (MIN. OF 5.5 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE) SLAB ON GRADE 3000 PSI (MIN. OF 5.5 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE) FOUNDATION WALL 3000 PSI (MIN. OF 5.5 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE) TOPPING N.A. a. TOTAL AIR CONTENT IS SPECIFIED IN THE TABLE ABOVE. AIR CONTENT TOLERANCE SHALL BE ± 1% AND SHALL BE MEASURED AT THE POINT OF PLACEMENT. (AFTER PUMPING IF APPLICABLE). ALL CONCRETE EXPOSED TO THE WEATHER SHALL HAVE AN APPROVED ADMIXTURE TO ENTRAIN AIR - 5% TOTAL AIR REQUIRED. CONCRETE THAT CAN BE SUBJECTED TO FREEZING AND THAWING DURING CONSTRUCTION SHALL BE AIR ENTRAINED. 3. PROVIDE GRADE 60 KSI (A615) FOR CONCRETE STEEL REINFORCING STEEL MEMBERS, HARDWARE, FASTENERS SHALL BE HOT DIPPED GALVANIZED OR EPDXY PAINTED PER ARCHITECT REQUIREMENTS. ALL CUT, REPAIRED AND EXPOSED SURFACE SHALL BE PAINTED WITH (2) COAT OF 95% ZINC RICH PAINT PER ASTM A780. COLOR TO MATCH EXISTING. STEEL SHALL CONFORM TO THE FOLLOWING STANDARDS: TUBE COLUMNS: ASTM A500, GRADE B (Fy = 46 KSI) WIDE FLANGE COLUMNS / BEAMS: ASTM 572 GR50 STEEL PIPE: SCHEDULE 40, CONFORMING TO ASTM A53, TYPE E OR S, GRADE B (Fy = 35 KSI.) ALL OTHER STEEL: ASTM A36 (Fy = 36 KSI) OR ASTM A992 BOLTS: ASTM A307 (WOOD/STEEL CONN) BOLTS: ASTM A325/A490 WITH LOCK WASHERS (STEEL/STEEL AND STEEL/GONG CONN) ANCHOR BOLTS: ASTM A307 (WOOD FRAMING) ANCHOR BOLTS: ASTM A325 (STEEL FRAMING) ALL SLIP CRITICAL CONNECTIONS SHALL BE ASTM A325 BOLTS AND SHALL BE ENGINEER -APPROVED, SELF -LOAD INDICATING TYPES, AND SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. STRUCTURAL STEEL WELDING CONFORM TO THE AWS CODES D1.1 AND D1.3, AND USE ONLY CERTIFIED WELDERS. WELDS NOT SPECIFIED ARE TO BE 1/4" CONTINUOUS FILLET MINIMUM. INCREASE WELD SIZE TO AWS MINIMUM SIZES, BASED ON PLATE THICKNESS. USE DRY E70 ELECTRODES. ALL WELDING SHALL CONFORM TO THE AWS CODES, AND SHALL BE BY CERTIFIED WELDERS. WELDS NOT SPECIFIED SHALL BE 1/4" CONTINUOUS FILLET MINIMUM. USE DRY E70 ELECTRODES. DRAWING LIST SHEET NUMBER SHEET NAME ISSUE DATE S-0 GENERAL NOTES AND SPECIFICATIONS 08-27-22 S-1 FRAMING PLANS AND DETAILS 08-27-22 Grand total: 2 info@b2engineers.com 425-318-7047 (0) 425-318-0031 (C) IF � WASNP0 // am' `s �r N Q- �.fj LPG 43789 OAl cTURA SS10 AL EN� SHARON STOCKER CONDO REMODEL Edgewood Condos 1110 5th Ave S, Unit 401 Edmonds WA 98020 PROJECT DATE: DRAWING SIZE 1811X24" ISSUE DATE 08-27-22 ISSUED FOR PERMIT PROJECT NO.22138 DESIGNER BB REVISION SCHEDULE NO. DATE I DESCRIPTION RECEIVED Sep 02 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-1172 GENERAL NOTES AND SPECIFICATIONS S-0 Copyright b2 Structural Engineers 2008 FLOOR PLAN 1 /411 = 1'-011 PROVIDE (2) 10d AT 24" EXISTING STUD WALL TO BE REMOVED Section 1 3/4" = 1'-0" NEW BEAM PER PLAN PROVIDE LUS HANGER 1—f — — — — — — — — — - TO EACH RAFTER CUT EXISTING ROOF RAFTERS I� I TO FIT NEW BEAM I I PROVIDE HUS HANGER FOR BEAM TO BEAM CONNECTION NEW BEAMS PER PLAN 7 ------------ Section 2 111 = 1'-01, II II II 1I I II II II II EXISTING 2X10 ROOF RAFTERS @ 16" O.C. TO REMAIN II II III II ii ii II II I I I I II II II II II II II II I II II II II II II h I I I II II II II II I I I I II II II II II I I I I I II II II II II II I I I PROVIDE L50 ANGLE @ EACH 1 2 END OF NEW BEAM (TYP.) S41 I II I$-1 II II II II II II II II I II II II II I I II II II II II II II II II II II II II II I II II II II II II II II II II II II II II II II II II II II II II I I I JL JL JL JL JL J� II II II II II II II II II II II I I II II II II II II II II II II II II II II NEW (3)2X10 DF#1 II II II BEAM (RB-2) II II II II II II II II II I I NEW II II II II II II II II II II II II II II II II II II II II I I BEM( (RB-1) II II II II II II II II II II II II II II II II II II II II II II II II II II II II II PROVIDE L50 ANGLE @ EACH END OF NEW BEAM (TYP.) II II II II II II II II II II II II Il b II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II II ROOF PLAN 1 /411 = 1'-011 �1t4�1� IZ PROVIDE (3) WSV3S SCREWS (BOTH SIDES) @ 24" O.C. (TYP.) EXISTING STUD WALL TO BE REMOVED IMPORTANT NOTES ON DRAWING REVIEW, FIELD VERIFICATION, TEMPORARY SHORING AND WATERPROOFING: 1. CONTRACTOR MUST REVIEW STRUCTURAL DRAWINGS PRIOR TO CONSTRUCTION & NOTIFY DESIGN TEAM/OWNER OF ANY DISCREPANCY IN COMPARISON WITH ARCHITECTURAL DOCUMENTS OR FIELD CONDITIONS. 2. IN REMODEL/RETROFIT PROJECTS, CONTRACTOR MUST FIELD VERIFY & NOTIFY DESIGN TEAM/OWNER OF EXISTING MECHANICAL, PLUMBING, AND ELECTRICAL LINES THAT MAY INTERFERE WITH STRUCTURAL WORK PRIOR TO CONSTRUCTION. STRUCTURAL DRAWINGS MAY NOT REFLECT ALL EXISTING FRAMING CONDITIONS DUE TO LIMITED AVAILABLE INFORMATION. 3. CONTRACTOR IS SOLELY RESPONSIBLE IN PROVIDING PROPER TEMPORARY SHORING PRIOR TO REMOVING ANY STRUCTURAL ELEMENTS. 4. ENGINEER IS NOT RESPONSIBLE FOR WATERPROOFING SYSTEM OR DETAILS. CONTRACTOR/OWNER SHALL CONSULT WITH QUALIFIED PROFESSIONALS AS REQUIRED FRAMING SYMBOLS_ p CONTINOUS P POST STOPS POST BELOW THIS FLOOR POST STARTS AT P THIS FLOOR PREPARED FOR SHARON STOCKER info@b2engineers.com 425-318-7047 (0) 425-318-0031 (C) �, of wASH/ j � S� N� q7 43789 O'c CTURAL ENS'\ G��� SSIONAL SHARON STOCKER CONDO REMODEL Edgewood Condos 1110 5th Ave S, Unit 401 Edmonds WA 98020 PROJECT DATE: DRAWING SIZE 18"X24" ISSUE DATE 08-27-22 ISSUED FOR PERMIT PROJECT NO.22138 DESIGNER BB REVISION SCHEDULE NO. I DATE I DESCRIPTION RECEIVED Sep 02 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FRAMING PLANS AND DETAILS S-1 n LEGEND AND NOTES 1 /4" = V-0" Copyright b2 Structural Engineers 2008