REVIEWED BLD2022-1172+Structural_Analysis_or_Calculations+9.1.2022_2.04.17_PM+3086607m NO 011 •
info@?b2engineers.com
425-318-7047(0)
425-318-0031(C)
RECEIVED
Sep 02 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
.....,...,..,.....,..
REVIEWED
BY
CITY OF EDMONDS c
BUILDING DEPARTMENT:
BLD2022-1172
SHARON STOCKER CONDO REMODEL
1110 5TH AVE S, UNIT 401, EDMONDS, WA 98020
STRUCTURAL CALCULATIONS
PROJECT NO: 22138 DATE:08/10/22
PREPARED BY: BASRI BASRI PE, SE
)esign Criteria
International Building Code (IBC) 2018
American Society of Civil Engineers (ASCE) 7-16
1 of 4
3roject Description
Interior remodel of the top floor unit include removal of (2) interior stud walls. (1) of the walls found to be load -
bearing. Structural design of new beams and columns to replace existing load -bearing wall. Please see
attached calculations for your reference
�
�Y�\ B 4
PF WAS o
0
Q-
�.A �'QL 43789
�Oc cTURA L G���
`SS/ONAL EN�
Project: SHARON STOCKER CONDO
Location: RB-1
Roof Beam
[2015 International Building Code(2015 NDS)]
(2)1.5INx9.25INx8.OFT
#2 - Douglas -Fir -Larch - Dry Use
Section Adequate By: 46.3%
2 of 4 page
Dennis
StruCalc 9.0
StruCalc Version 10.2.1.0 8/10/2022 10:40:55 AM °f
Controlling Factor: Moment
CAUTIONS
. Laminations are to be fully connected to provide uniform transfer of loads to all members
DEFLECTIONS Center
Live Load 0.07 IN L/1434
Dead Load 0.03 in
Total Load 0.10 IN L/951
Live Load Deflection Criteria: L/240 Total Load Deflection Criteria: L/180
REACTIONS A B
Live Load 920 lb 920 lb
Dead Load 467 lb 467 lb
Total Load 1387 lb 1387 lb
Bearing Length 0.74 in 0.74 in
BEAM DATA
Span Length 8 ft
Unbraced Length -Top 0 ft
Unbraced Length -Bottom 0 ft
Roof Pitch 1 :12
Roof Duration Factor 1.15
Notch Depth 0.00
MATERIAL PROPERTIES
#2 - Douglas -Fir -Larch
Base Values
Adjusted
Bending Stress:
Fb = 900 psi
Fb' = 1139 psi
Cd=1.15 CF=1.10
Shear Stress:
Fv = 180 psi
Fv' = 207 psi
Cd=1.15
Modulus of Elasticity:
E = 1600 ksi
E' = 1600 ksi
Comp. -L to Grain:
Fc -1= 625 psi
Fc - -L = 625 psi
Controlling Moment:
2774 ft-lb
4.0 ft from left support
Created by combining all dead
and live loads.
Controlling Shear:
-1137 lb
At a distance d from support.
Created by combining all dead
and live loads.
Comparisons with required sections: Read
Provided
Section Modulus:
29.24 in3
42.78 in3
Area (Shear):
8.24 in2
27.75 in2
Moment of Inertia (deflection):
37.45 in4
197.86 in4
Moment:
2774 ft-lb 4059 ft-lb
Shear:
-1137lb
3830lb
LOADING DIAGRAM
a
ROOF LOADING
Side One:
Roof Live Load:
ILL =
25
psf
Roof Dead Load:
DL =
12
psf
Tributary Width:
TW =
9.2
ft
Side Two:
Roof Live Load:
ILL =
0
psf
Roof Dead Load:
DL =
0
psf
Tributary Width:
TW =
0
ft
Wall Load:
WALL =
0
plf
SLOPE/PITCH ADJUSTED LENGTHS AND LOADS
Adjusted Beam Length:
Ladj =
8
ft
Beam Self Weight:
BSW =
6
plf
Beam Uniform Live Load:
wL =
230
plf
Beam Uniform Dead Load:
wD_adj =
117
plf
Total Uniform Load:
wT =
347
plf
Project: SHARON STOCKER CONDO
Location: RB-2
Roof Beam
[2015 International Building Code(2015 NDS)]
( 3 ) 1.5 IN x 9.25 IN x 18.3 FT
#1 - Douglas -Fir -Larch - Dry Use
Section Adequate By: 16.1%
3 of 4 page
Dennis
StruCalc 9.0
StruCalc Version 10.2.1.0 8/10/2022 10:40:55 AM °f
Controlling Factor: Moment
CAUTIONS
. Laminations are to be fully connected to provide uniform transfer of loads to all members
DEFLECTIONS Center
Live Load 0.40
IN L/546
Dead Load 0.25
in
Total Load 0.65
IN L/337
Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: L/240
REACTIONS A
B
Live Load 452
lb 468 lb
Dead Load 312
lb 320 lb
Total Load 764
lb 788 lb
Bearing Length 0.27
in 0.28 in
BEAM DATA
Span Length
18.3 ft
Unbraced Length -Top
0 ft
Unbraced Length -Bottom 0 ft
Roof Pitch
1 :12
Roof Duration Factor
1.15
Notch Depth
0.00
MATERIAL PROPERTIES
#1 - Douglas -Fir -Larch
Base Values
Adjusted
Bending Stress:
Fb = 1000 psi
Fb' = 1455 psi
Cd=1.15 CF=1.10 Cr-1.15
Shear Stress:
Fv = 180 psi
Fv' = 207 psi
Cd=1.15
Modulus of Elasticity:
E = 1700 ksi
E' = 1700 ksi
Comp. -L to Grain:
Fc -1= 625 psi
Fc - -L = 625 psi
Controlling Moment: 6698 ft-lb
9.15 ft from left support
Created by combining all dead and live loads
Controlling Shear: -781 lb
At a distance d from support.
Created by combining all dead and live loads
Comparisons with required sections:
Read
Provided
Section Modulus:
55.25 in3
64.17 in3
Area (Shear):
5.66 in2
41.63 in2
Moment of Inertia (deflection):
211.25 in4
296.79 in4
Moment:
6698 ft-lb
7780 ft-lb
Shear:
-781 lb
5744lb
LOADING DIAGRAM
18.3 ft
ROOF LOADING
Side One:
Roof Live Load:
ILL =
0
psf
Roof Dead Load:
DL =
0
psf
Tributary Width:
TW =
0
ft
Side Two:
Roof Live Load:
ILL =
0
psf
Roof Dead Load:
DL =
0
psf
Tributary Width:
TW =
0
ft
Wall Load:
WALL =
0
plf
SLOPE/PITCH ADJUSTED LENGTHS AND LOADS
Adjusted Beam Length:
Ladj =
18.3
ft
Beam Self Weight:
BSW =
9
plf
Beam Uniform Live Load:
wL =
0
plf
Beam Uniform Dead Load:
wD_adj =
9
plf
Total Uniform Load:
wT =
9
plf
POINT LOADS - CENTER SPAN
Load Number One
Live Load 920 lb
Dead Load 467 lb
Location 9.3 ft
. Load obtained from Load Tracker. See Summary Report for details.
Project: SHARON STOCKER CONDO 4 of 4 page
Dennis
Location: P-1 StruCalc 9.0
Column StruCalc Version 10.2.1.0 8/10/2022 10:40:56 AM °f
[2015 International Building Code(2015 NDS)]
(2)1.5INx3.5INx8.OFT
Stud - Hem -Fir - Dry Use
Section Adequate By: 29.4%
CAUTIONS
. Laminations to be nailed together per National Design Specifications for Wood Construction Section 15.3.3.1
VERTICAL REACTIONS
Live Load: Vert-LL-Rxn = 920 lb
Dead Load: Vert-DL-Rxn = 483 lb
Total Load: Vert-TL-Rxn = 1403 lb
COLUMN DATA
Total Column Length: 8 ft
Unbraced Length (X-Axis) Lx: 0 ft
Unbraced Length (Y-Axis) Ly: 8 ft
Column End Condition-K (e): 1
Axial Load Duration Factor 1.00
COLUMN PROPERTIES
Stud - Hem -Fir
Base Values
Adjusted
Compressive Stress:
Fc = 800 psi
Fc' =
189 psi
Cd=1.00 Cf=1.05 Cp=0.23
Bending Stress (X-X Axis):
Fbx = 675 psi
Fbx' =
743 psi
Cd=1.00 CF=1.10
Bending Stress (Y-Y Axis):
Fby = 675 psi
Fby' =
743 psi
Cd=1.00 CF=1.10
Modulus of Elasticity:
E = 1200 ksi
E' = 1200
ksi
Column Section (X-X Axis):
dx =
3.5
in
Column Section (Y-Y Axis):
dy =
3
in
Area:
A =
10.5
in2
Section Modulus (X-X Axis):
Sx =
6.13
in3
Section Modulus (Y-Y Axis):
Sy =
2.63
in3
Slenderness Ratio:
Lex/dx =
0
Ley/dy =
32
Column Calculations (Controlling Case Only):
Controlling Load Case: Axial Total Load Only (L + D)
Actual Compressive Stress:
Fc =
134
psi
Allowable Compressive Stress:
Fc' =
189
psi
Eccentricity Moment (X-X Axis):
Mx -ex =
0
ft-lb
Eccentricity Moment (Y-Y Axis):
My-ey =
0
ft-lb
Moment Due to Lateral Loads (X-X Axis):
Mx =
0
ft-lb
Moment Due to Lateral Loads (Y-Y Axis):
My =
0
ft-lb
Bending Stress Lateral Loads Only (X-X Axis):
Fbx =
0
psi
Allowable Bending Stress (X-X Axis):
Fbx' =
743
psi
Bending Stress Lateral Loads Only (Y-Y Axis):
Fby =
0
psi
Allowable Bending Stress (Y-Y Axis):
Fby' =
743
psi
Combined Stress Factor:
CSF =
0.71
LOADING DIAGRAM
B
8ft
A
AXIAL LOADING
Live Load:
PL =
920 lb
Dead Load:
PD =
467 lb'
Column Self Weight:
CSW =
16 lb
Total Axial Load:
PT =
1403 lb
. Load obtained from
Load Tracker. See Summary Report for details.