Loading...
RESUB 1 - FIR2021-0116+Fire_Alarm_Equipment_Specification_Sheets+12.8.2021_3.46.25_PM+2561335FIR2021-0116 RESUB Dec 09 2021 TABLEO F CONTENTS DEVCITY E ELOPMM ENTT SSERVI ERVICES DEPARTMENT 1. SCOPE OF WORK (1 PAGE) 2. SILENT KNIGHT 6700 FIRE ALARM PANEL (4 PAGES) 3. SILENT KNIGHT SS60 REMOTE ANN. (Z PAGES) 4. AES MODEL 7707P-44-ULP RADIO (4 PAGES) S. SILENT KNIGHT SK-PHOTO-W SMOKE DET. (3 PAGES) 6. THERMOTECH 302-ET- 7.35 WP HEAT DET. (Z PAGES) 7. SILENT KNIGHT SK-MINIMON MONITORS (2 PAGES) B. SILENT KNIGHT SK-PULL-SA PULL STATION (2 PAGES) 9. SILENT KNIGHT SK-RELAY RELAY MODULE (Z PAGES) 10. SYSTEM SENSOR PZRK WP HORN STROBE (4 PAGES) RESUB 16d 11c PO BOX B04 VASH❑N WA, 9B070 SCOPE OF WORK SUNDSTONE CONDOS 1414 _ AVE N EDMONDS, WA 9BO20 OVERVIEW Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FOR THE PURPOSE OF ELEVATOR MODERNIZATION; INSTALL A NEW ADDRESSABLE DEDICATED PURPOSE ALARM PANEL FOR THE PURPOSE OF ELEVATOR CONTROL. PLACARD THE PANEL AS DEDICATED ELEVATOR CONTROL EQUIPMENT. INSTALL ADDRESSABLE SMOKE DETECTION IN THE ELEVATOR LOBBIES, ELEVATOR MACHINE ROOM AND AT THE CONTROL PANEL. INSTALL ADDRESSABLE CONTROL RELAYS IN THE ELEVATOR MACHINE ROOM FOR ELEVATOR RECALL AND HAT LIGHT FUNCTIONS. INSTALL MANUAL STATIONS IN THE CENTER LOBBIES AT THE STAIRS. INSTALL CENTRAL NOTIFICATION 4 DEVICES. INSTALL REMOTE ANNUNCIATOR AT FD RESPONSE IN LOBBY. THE BUILDING IS NOT SPRINKLED. NO FIRE ALARM EQUIPMENT IS EXISTING. MONITORING TO BE PROVIDED BY AES RADIO COMMUNICATOR. CONTROL PANEL: THE NEW FIRE ALARM PANEL WILL BE SILENT KNIGHT BRAND MODEL 6700 ADDRESSABLE FIRE ALARM. WIRING: ALL WIRING WILL BE FPLP OR BETTER RATED AND SIZED AS FOLLOWS: SLC CIRCUITS WILL BE AWG 1 B OR GREATER INITIATING CIRCUITS WILL BE AWG 14 OR GREATER RATED FOR THE ENVIRONMENT AND INSTALLED IN EMT. INSTALLATION: INSTALLATION WILL BE PERFORMED IN ACCORDANCE WITH NFPA 70, NFPA 72 AND APPLICABLE PROVISIONS OF THE WASHINGTON ADMINISTRATION CODE. TECHNICIANS FROM 16D, LLC, CERTIFIED BY THE STATE OF WASHINGTON AND UNDER PERMIT BY THE AUTHORITY HAVING JURISDICTION WILL PERFORM ALL INSTALLATION. TESTING AND WARRANTY: A COMPLETE TEST WILL BE PERFORMED IN THE PRESENCE OF THE OWNER, AND ANY OTHER AUTHORITY HAVING JURISDICTION DEEMED APPROPRIATE. FOLLOWING AN ACCEPTABLE TEST RESULT, THE OWNER AND 1 60, LLC. WILL SET THE TERMS FOR WARRANTY SERVICE AND ARRANGE A CONFIDENCE TESTING SCHEDULE. 7 6D LLC WILL PROVIDE SYSTEMS TRAINING TO THE OWNER TO ENSURE PROPER OPERATIONS. Honeywell 5ILENT'' KNIGHT C:U1111 Addressable Fire Alarm Control Panels Addressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel (FACP) that is a direct replacment for the 5700 FACP. The 6700 can be configured to achieve a point capacity of up to 100 points. It has one built-in signaling line circuit (SLC), which can support 50 System Sensor' (SK) sensors and 50 SK modules or 50 Hochiki° (SD) devices. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. The 6700 also has a built-in, dual -line POTS and IP communicator with additional cellular options available. The 6700 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent atthe panel. SWIFT° wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard -to -wire locations, buildings where new wiring is not allowed, orto provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard -wired 6700 compatible devices. SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has a form-C trouble relay, two programmable form-C relays, along with powerful features such as drift compensation, pre - trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. FEATURES & BENEFITS • Capable of providing up to 100 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single - point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models • Convenient field-upgradeable firmware • Built-in dual path POTS and IP communications with optional cellular models available for reliable backup reporting • 6860annunciatorwith a 4 x 40 large display • Four user - programmable buttons minimize time spent executing complex or routine tasks • Built-in USB interface for convenient and quick programming RESU Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES 6700 The 6700 supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL power module, and SK or SD devices. • Programmable date setting for automatic and convenient Daylight Saving Time changes • JumpStart° auto programming reduces installation time • 125 software zones and 125 output groups for flexible design options SIGNAL LINE CIRCUIT (SLC) The 6700 SLC loops support multiple device types, maintenance alerts, and a built-in sensor test to comply with NFPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Trouble (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes forAC failure; solid when power systems are normal USERINTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy -to -use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStart° auto programming minimizes programming required to start a new system. The built-in keypad, or the 6860, 5860 or 6855 remote RESUB ORDERING INFORMATION Dec 09 2021 6700: Addressable Fire Alarm CITY OF EDMONDS Control Panel. (Red cabin@EYELOPMENTSERVICES DEPARTMENT ld•]kkv,1]eAIII W11=FA21IZLIR[d/e1i 6860: 4x40 LCD remote fire annunciator (4 lines and up to annunciators give you on -site access to 160 characters) per system; four current system programming. programmable buttons Programming can also be accomplishe5860:4x20 LCD remote fire using the Windows° -based Honeywell annunciator. 5860 is gray; 586OR is red Fire Software Suite (HFSS) program. 6855:4x20 LCD remote fire annunciator SOFTWARE TOOLS 5865-3 or 5865-4: LED annunciators SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows° software system configuration toolto create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires PC running Microsoft' Windows°. ADDITIONAL INFORMATION Twisted -unshielded pairwire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NPFA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signaling services • UL Listed: S2766 • CSFM 7165-0559:0501 • FDNY COA# 6250 can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. --->53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories, visit www.sitentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. Page 2 of 4 — 3516073 9/26/2018 SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135OF fixed temperature SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T. Reflected beam smoke detector with testfeature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended airspeed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-W: Fixed thermal detector (135°F), white SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-ROR-W: Fixed rate of rise detector (135°F), white SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-HEAT-HT-W: Fixed high temperature thermal detector (19019, white SK-ISO: Fault isolator module -->SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector --->SK-PHOTO-W: Photoelectric smoke detector, white SK-PHOTO-T: Photoelectric smoke detector with thermal (135°F fixed temperature) SK-PHOTO-T-W: Photoelectric smoke detector with thermal (135°F fixed temperature), white SK-PHOTOR: Photoelectric detector with remote test capability SK-PHOTO-R-W: Photoelectric detector with remote test capability, white -->SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station ---->SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2:Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B300-6(-IV): 6" base for SK-W Series B21OLP: 6" mounting base B501(-BL,-IV,-WHITE):4"flangeless base B501:4" Flangeless mounting base B200S(-IV,-WH): Intelligent sounder base B20OS: Intelligent sounder base B200S-LF(-IV,-WH): Low -Frequency intelligent sounder base B20OS-LF: Low -frequency intelligent sounderbase B224RB(-IV,-WH): Relay base B224RB: Relay base B224B1(-IV,-WH): Isolator base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-61B: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for theSD505-DUCTR SD505-DUCT:Addressable Duct Smoke Detector. SD505-DUCTR:Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 1350E-150OF(OOC-370C). SD500-LIM: Addressable Line isolator module SD500-MIM:Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA:Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.sitentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. RESUB WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Ph0e&Nc2021 smoke detector CITY OF EDMONDS WSK-PHOTO-T. Wireless MinsKFTI_@IjfffiIfbSERVICES photoelectric smoke detectorJKiATMl detection (1350F fixed temperature) and 3510W 4" base WSK-HEAT: Wireless Heat, (1351Ffixed temperature) and B51OW 4" base WSK-HEAT-ROR: Wireless heat, ROR (135°F fixed temperature) and B51OW 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFT Tools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power -limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/Parallel printer interface module for printer connection. 5895XL: Power supply with six Flexput° circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8"W x 10-3/16"H x 3"D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL -MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorAlarm® receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications linkforthe 6700 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode, transmitter and receiver SK-FSL: Fiber -Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. Page 3 of 4 — 351607:13 9/26/2018 RESUB 6700 Technical Specifications Dec 09 2021 PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) Flexpute, Hone well°, os Overall Dimensions: 12.71" W x 15.12" H x 3.33" D Two programmable circuits which can be JumpStar�°Ei� RVICEs SWIFT°, and SY0112WRTMENT Weight: 15 lbs. programmed individually as: Sensor' are registered Color: Red NACs: 2.5A C 27.4VDC per circuit, power -limited trademarks of Honeywell (with a panel maximum current of 2.5A) International Inc. Auxiliary Power Circuits: 2.5A C� 27.4VDC per ENVIRONMENTAL circuit, power -limited Hochiki° is a registered Operating Temperature: 32°Fto 120°F (01Cto trademark of Hochiki 49°C) Corporation. Microsoft® Humidity:0 to 93% relative humidity(non- Supports Class B (Style 4) and Class A (Style 6 or 7) and Windows° are configuration for the SLC registered trademarks of condensing) Microsoft Corporation. ELECTRICAL WIRING: Seethe product manual for wiring details This document is not 6700 Primary AC: 120 VAC C 60 Hz,1.5A Total intended to be used for installation We Accessory Load: 2.5A C� 27.4 VDC power -limited try tokeep our product Standby Current: 165mA information up -to Alarm Current: 310mA date and accurate. We Battery Charging Capacity: 7 to 35AH cannot cover all specific Battery Size: 7AH max. allowed in control panel applications or anticipate all requirements. All cabinet. Larger capacity batteries can be housed in specifications are subject RBB accessory cabinet. to change without notice. For Technical Support, call 800-446-6444. Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 Honeywell 800-328-0103 EN 3e1607 I e I osila SILENT' www.sitentknight.com © 2018 Honeywell International Inc. IQtiTIGI-TF Honeywell ®SILENT' NIGHT Remote Annunciator The 5860 remote annunciator, can be used to operate and program Honeywell Silent Knight fire alarm control panels (FACPs) from anywhere within the system. The 5860 features include an 80-character backlit LCD providing easy -to understand system messages. The annunciator is ergonomically designed with over -sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed c for alarm, supervisory, trouble, silence, and The 5860 annunciator is available in gray red for applications where the annunciator annunciator enclosure can be surface or fll available for surface mounting. h virtually any decor and COMPATIBILITY The 5860 is compatible with the following Honeywell Silent Knight FACPs: 6820: Addressable fire alarm control panel with up to 1,110 addressable points 6820EVS: Addressable fire alarm control panel with an emergency communication systems and up to 1,110 addressable points 6808: Addressable fire alarm control panel with up to 198 addressable points >6700: Addressable fire alarm control panel with up to 100 addressable points 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency communication systems 5808: Addressable fire alarm control panel 5700: Addressable fire alarm control panel FEATURES & BENEFITS • 80-character backlit LCD display (4 Lines with 20 characters per line) • Tactile / audible feedback when a key is pressed on the annunciator • Uses the RS-485 SBUS to interface with the panel • Supportfor simultaneous use of multiple 5860s • Easily view current status by alarms, supervisories, or troubles • Five Status LEDs • Available in red or light gray color • Accommodates wiring lengths up to 6000 ft. from the control panel for added design and install flexibility Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT • Accepts user codes or fire fighter's key • Larger keypad buttons makes it easier to maneuver for system reset and silencing 5860 Technical Specifications Compatible Silent Knight FACP Wire Runs Up to 6000 Feet From FACP oa mu oa�e my �d�o mn ��m� 5860 5880 5860 to Eight 5860s Per 5700 or 6700 System to 12 5860s Per 5808, 6808, 5820XL, or 5820XL-EVS System • Up to 16 5860s per 6820 or 6820EVS System 5860 Features PHYSICAL ORDERING INFORMATION Dimensions: 9.1"W x 7.4"H x 1.5"D (23.1W x 18.8H x 5860: Remote Annunciator, four line (4x20) LCD 3.8D cm) annunciatorwith 20 characters per line. Gray Shipping Weight: 2.8 lbs (1.3 kg) -> 5860R: Remote Annunciator, four line (4x20) LCD Color: 586OR: Red; 5860: Gray annunciatorwith 20 characters per line. Red ENVIRONMENTAL Operating Temperature:32°Fto 1201F(0°Cto 49°C) Humidity: 10%- 93% non -condensing) ELECTRICAL Operating Voltage: 24VDC Standby Current: 20mA Alarm Current: 25mA For more information Learn more about Honeywell Silent Knight and other products byvisiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 ACCESSORIES 5860TR: Red Trim Ring for surface mounting 5860TG: Gray Trim Ring for surface mounting AGENCY LISTINGS AND APPROVALS UL listed CSFM approved Meets NFPA 72 requirements FM approved MEA approved Doc 350224 1 Rev J 112/17 © 2017 Honeywell International Inc. RESUB Dec 09 2021 For acomplete ,listtin of all complian�PEtlEL RP7IF�DS VCES certifications, �gil�IT www.sitentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight° and Honeywell' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up -to date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call800-446-6444. Honeywell SILENT' KNIGHT mow► w' ES-4� ,fSECURITY CORPORATION INNOVATION 7707 Fire Subscribers IntelliNet Introducing a Newer, Smarter Alarm Communications Platform New Feature Highlights aeRn-U S Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT • Leverages state of the art technology • Applies advanced security protection no • Offers flexible power and configuration options NFPA • Engineered for backward compatibility with legacy systems • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Improves functionality with an adaptive Graphic User Interface (GUI) for programming via smartphones, tablet and PCs • Plus many more... U� LISTED Key Benefits that Make 2.0 the Best Alarm Monitoring Solution Ever • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP) without requiring an electrician onsite and without Subscriber backup battery (2) Directly from the FACP with Subscriber backup battery; or (3) Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards Enhanced Wireless Fire Alarm Monitoring RESUB Dec 09 2021 Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next gene rat4WOF EDMONDS universal wireless communicators that provide advanced security protection for any new or existing DEVELOPMENT SERVICES monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option, they are the ideal drop -in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D} Burglary Subscriber-—-—---—-—-—-—- wr B r I N i ► I rr 1 BJFire r r Subscriber I I I I Mi,Nen 4RioneBeM.n!SrsMm B — -- — Ay Alarm Primary AES-MuVrlNer Re(river - - I I I I I Panel I I Selo ndary AE S•MuIflNef He[eluer r' I I r B I B •C Alarm Automation A _ _ _ _ _ _ _ Q IIP Links Customer Location Mesh Radio Technology Central MonIto ring Staticn Alarm Panel & AES Su bs(ri per Multi-patlr AE S-!rrtel iNel® Network Prilrra ry& Secon da ry AES-h1ujdNet Syslern sends critical ever r[signal delivers alarm sign als via smart routing, receives transmi ssia n in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add -on accessory board. AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: http://aes-corp.com/products/fire/fire-marshal-resources/ How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers PREMIUM (UL & ULC Listed, Available Now!) CITY OF EDMONDS IJEVEI7707P-88 IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones, with integrate on Local Annunciator, Red Enclosure IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794A AES-IntelliPro 7707P-88-ULP and integrated onboard Local Annunciator, Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones, with integrated onboard 7707P-44 Local Annunciator, Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones with 7794A AES-IntelliPro 7707P-44-ULP and integrated onboard Local Annunciator, Red Enclosure 2.0 FEATURE ADD (Pending UL Review) IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies 7707P-88-M (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated 7707P-88-ULP-M onboard Local Annunciator plus MCT, Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone with Multiple Communication Technologies 7707 P-44-M (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone with 7794A AES-IntelliPro, and integrated 7707P-44-ULP-M onboard Local Annunciator plus MCT, Red Enclosure 7707M-UPG IntelliNet 2.0 Fire MCT Software Upgrade 2.0 ACCESSORIES Standalone AES-IntelliPro Fire full data module add -on accessory board with 7794A firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy• •- 7706-ULF Integrated Fire Monitoring System, Red Enclosure Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module, 7788F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, 7788F-ULP Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module, 7744F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, 7744F-ULP Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones, 7744F Red Enclosure LEGACY ACCESSORIES Standalone AES-IntelliPro Fire full data module add -on accessory board for legacy 7794 units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications DIMENSIONS 13"H x 8.5"W x 4.5"D (33cmH x 21.5cmW x 11.4cmD) WEIGHT 5.8 Ibs (2.6 kilograms) excluding battery 13 Ibs (5.9 kilograms) with 10 Ah battery RADIO FREQUENCY Standard Frequency Range: 450-470 MHz Contact AES for other UHF and VHF frequencies ANTENNA 2.5 dB tamper resistant antenna included, mounts on enclosure Optional remote mounting antenna available POWER INPUT AC SOURCES Transformer: Class 2 16.5V AC nominal output 1.9 A max current (40 VA MIN) ELK ELK-TRG1640, MG ELECTRONIC SALES MGT1640, or AES 1640 (not included) DC SOURCES (includes FACP) 24V DC Regulated Power Supply with Subscriber Rechargeable Battery 1.9 A max current BACKUP BATTERY 10-12 Ah, UL recognized lead acid gel cell, size based on subscriber configuration Contact Us ALARM SIGNAL INPUTS/ZONES 8 individually programmable E.O.L. type zone inputs 4+4: 4 reverse polarity input and 4 individually programmable E.O.L. type zone inputs Optional 7794A AES-IntelliPro for full data via Contact ID, Pulse, Modem Ile and Modem IIla2 UL LISTINGS UL 864 loth Edition Standard for Control Units and Accessories for Fire Alarm Systems ULC S559-04 1st Edition Equipment for Fire Signal Receiving Centres and Systems TROUBLE OUTPUT—ACK DELAY/ANTENNA CUT Form C relay, fail secure, rated 24V DC 1A resistive, unsupervised RESET BUTTON Located on main circuit board OPERATING TEMPERATURE 32 to 120°F (0 to 49°C) STORAGE TEMPERATURE 14 to 140°F (-10 to 60oC) RELATIVE HUMIDITY 0 to 93%, non -condensing RECHARGE CAPABILITY Will charge 12V battery size from 10-12 Ah Dec 09 2021 PORTS CITY OF EDMONDS Ethernet for confi g uration ELOPMENDEPARTMMENTENTSERCES and message communication USB access for software upgrade REMOTE ANNUNCIATOR AES Model 7740 Remote Annunciator, supervised COMPATIBLE RECEIVERS 7705i AES-MultiNet Receiver CONFIGURATION INTERFACE Web browser capable device accessible via smartphone, tablet, laptop, or PC CURRENT CONSUMPTION Standby w/ charged backup battery: 200 mA (1.2 A Transmitting) Standby + charging backup battery: 900 mA (1.9 A Transmitting - MAX) POWER OUTPUT 2 or 5 Watts Factory set ENCLOSURE MATERIAL Steel with paint finish FINISH COLOR Red VISUAL INDICATORS Front panel LIED (2 x 20 alphanumeric character backlit display) Power and Trouble LEDs (ALM, Trouble, Tx, Rx, WA) For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. IJF =9:40- mWSERI MB 21 Addressable Photoelectric Smoke DetectorsDMONDS CITY M ETSERVI DEVELOPMENT SERVICES DEPARTMENT The Silent Knight"' SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SK-PHOTO Series detectors. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (5710 fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DN R Series duct detector housings. FEATURES AND BENEFITS • Designed to meet UL 1268 7th Edition • Sleek and stylish contemporary design • Stable communication technique with noise immunity • Addressable by device • Rotary, decimal addressing (Refer to the Silent Knight panel manuals for device capacity) • Two -wire SLC connection • LEDs blink everytime the unit is polled • 3601-field viewing angle of the visual alarm indicators (two bi-color LEDs); LEDs blink green in Normal condition and turn on steady red in Alarm • Integral communications and built-in device -type identification • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Walk testwith address display (an address of 121 will blink the detector LED 12- (pause)-1) • Low standby current • Built-in tamper -resistant feature • Designed for direct -surface or electrical - box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • Expanded color options • SEMS screws forwiring of the separate base • Optional remote, single -gang LED accessory • Optional sounder, relay, and isolator bases Honeywell SILENT' KNIGHT INSTALLATION The SK-PHOTO-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see SK-61045. Note: Because of the inherent supervision provided bytheSLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class "B") wiring. Note: When using relay or sounder bases, consult the SK-ISO installation sheet 156-3627 for device limitations between isolator modules and isolator bases. OPERATION Each SK-PHOTO-W Series detector uses one of the panel's addresses (total limit is panel dependent) on the Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SK-PHOTO-W Series offers features and performance that represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note: "-IV" suffix indicates ivory color. SK-PHOTO-W: White, low -profile photoelectric sensor SK-PHOTO-T-W: White, same as SK-PHOTO-W but includes a built-in 1350F (57°C) fixed -temperature thermal device SK-PHOTO-R-W: White, low -profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW B300-6: White, standard flanged low -profile mounting base B300-6-BP: Bulk pack of B300-6, package contains 10 B300-6-IV: Ivory, standard flanged low -profile mounting base B501-WHITE: White, standard European flangeless mounting base B501-BL: Black, standard European flangeless mounting base B501-IV: Ivory, standard European flangeless mounting base B501-WHITE-BP: Bulk pack of 3501-WHITE, contains 10 B20OS-WH: White, Intelligent, programmable sounder base B20OS-IV: Ivory, Intelligent, programmable sounder base B200SR-WH: White, Intelligent sounder base for retrofit applications B200SR-IV: Ivory, Intelligent sounder base for retrofit applications B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounderbase B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounderbase B200SR-LF-WH: White, Low Frequency IntelligenR T SUB for retrofit applications Dec 09 2021 B200SR-LF-IV: Ivory, Low Frequency Intelligent soL F4NfWs retrofits applications DEVELOPMENT SERVICES Pp DEPARTMENT B224RB-WH: White, plug-in System Sensor' relay base B224RB-IV: Ivory, plug-in System Sensor relay base B224BI-WH: White, plug-in System Sensor isolator detector base B224BI-IV: Ivory, plug-in System Sensor isolator detector base ACCESSORIES TR300: White, replacement flange for B21OLP or B300-6 bases TR300-IV: Ivory, replacement flange for B21OLP or B300-6 bases RA100Z(A): Remote 3 - 32 VDC LED annunciator, mounts to a U.S. single -gang electrical box, for use with B501 and B300-6 bases only M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: White, detector color kit, pack of 10 CK300-IV: Ivory, detector color kit, pack of 10 CK300-BL: Black, detector color kit, pack of 10 Page 2 of 3 — 351634:13 • 7/1/2019 SK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS RESUB PHYSICAL/ENVIRONMENTAL Sensitivity: - UL Applications: 0.5% to 4.0% per foot obscuration. - ULC Applications: 0.5%to 3.5% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter - B300-6: 6.1" (15.6 cm) diameter - B501: 4" (10.2 cm) diameter For a complete list of detector bases, see SK-61045. Shipping weight: 3.4 oz. (95 g) Operating temperature range: • SK-PHOTO-W:32°Ftol22°F(0°Cto50°C) • SK-PHOTO-T-W: 32°F to 100°F(0°C to 38°C) • SK-PHOTO-R-W installed in a DNR/DNRW: -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/ min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10%— 93% non - condensing Thermal ratings: fixed -temperature set point 1350F (57C), rate -of -rise detection 15°F (8.3°C) per minute, high temperature heat 190OF(88°C) ELECTRICAL SPECIFICATIONS Voltage range:15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communication every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC ("ON") Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.sitentknight.com DETECTOR SPACING AND APPLICATIONS Silent Knight recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications referto N FPA 72. A System Smoke Detector Application Guide, documentA05-1003, is available at www.systemsensor.com. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document.ln some cases, certain modules or applications may not be listed bycertain approval agencies, or listing may be in process. Consult factory for latest listing status. • ULListed:S6173 • FM Approved • CSFM:7272-0559:0512 351634 1 B 1 07/19 ©2019 Honeywell International Inc. Honeywell SILENT' KNIGHT Four Basic Models MODEL DESCRIPTION REFER TO: 302-135 135°F - Interior Vertical Mounting FM & UL Fig.1 302-194 194°F - Interior Vertical Mounting FM & UL 302-ET-135 135°F - All Weather Vertical Mounting FM & UL Fig. 2 302-ET-194 194°F - All Weather Vertical Mounting FM & UL 302-AW-135 135OF - All Weather Vertical Mounting FM & UL Fig. 3 302-AW-194 1940F - All Weather Vertical Mounting FM & UL 302-EPM-135 135°F - Explosion Proof Mounting UL Fig. 4 302-EPM-194 194°F - Explosion Proof Mounting UL Decorative white plastic adapter plate for mounting 302, 302E1 AP P and 302AW to any 3" outlet box or 4" octagon outlet box. Fig. 5 - > Fig. 2 MODEL 302-ET Hermetically sealed for moisture proof or dust proof installations. Requires no special back box. Has plastic hexago- nal grip bushing with 1/2" conduit threads for attachment to threaded hub cover, or any outlet box. Must be hand tightened only. For indoor and outdoor use. Protect from direct sunlight and adverse weather conditions. F Fig. 4 MODEL 302-EPM Explosion proof for installation in hazardous locations. Has hexagonal grip bushing with 1 /2' conduit threads for attach- ment to threaded hub cover of series JL fixture fitting as manu- factured by Killark Electric Co., or equal. Must be hand tightened only. For Interior use. Fig.1 MODEL 302 For interior mounting in any atmosphere that is compat- ible with terminal screw type connections. Fig. 3 MODE�L3'0'2"- A Hermetically sealed for moisture proof or dust proof installations. Requires no special back box. For indoor and outdoor use. Protect from direct sunlight and adverse weather conditions. Fig. 5 AP-P Decorative white plastic adapter plate for mounting 302, 302-AW and 302-ET detectors only. General Each model is a normally open device designed especially for fire detection and alarm systems. These rate compensation type detectors are available in either 1350 F. or 1940 F. ratings. All four basic models are self restoring, hermetically sealed, shock and corrosion resistant, and are tamper proof. Refer to NFPA STANDARD 72, STANDARD FOR AUTOMATIC FIRE DETECTORS for application requirements, testing and maintenance. Principal of Operation All models operate on the principles of a rate compensation detec- tor. The detector consists of a high expansion aluminum tube which encases two insulation struts with opposing open constant points (see cut -away view). The high expansion sensing shell and the expan- sion struts have a different coefficient of expansion. A slow rate of temperature rise allows the heat to penetrate the inner expansion struts. Therefore, the tubular shell and the struts expand slowly until the total device has been heated to its rated temperature level of 1350 F./1940F. At this point, the silver contact points close which initiates the alarm. When subjected to a rapid rate temperature rise there is not as much time for heat to penetrate the inner strut. The rapid lengthening of the shell allows the struts to come together at a lower level which compensates for thermal lag inherent in conventional fixed temperature detectors. When the surrounding air temperatures goes below the rated temperature level, the shell contracts which forces contacts to open, thus automatically resetting the detector. Special Considerations Temp. Rating OF. Max Ceiling Temp. OF. 135 115 194 155 Detectors are not directionally effected, can be mounted horizontally or vertically. Detectors have a smooth ceiling UL rating of 50' x 50' (2500 sq. ft.) on 8 to 10 ft. ceilings. Detectors, hub covers, or outlet boxes must never be installed in direct sunlight. Refer to NFPA STAN- DARD 72 for spacing and other considerations. For further information refer to www.thermotechheatdetectors.com (actual size) ilver contact points sion struts expansion sensing 040 anodized ;ontrol sleeve g screw n hermetic seal Dimensions (Model 302): Total overall length 4 t/s Base Diameter: 2". Approvals/Listings Signaling tUnderwriters' Laboratories Listed ' Factory Mutual Approved �ST� Electrical Rating '� California State Fire Marshall. Listing No.7270-0021:001 Voltage Current NEtV YOf1K CITY MEA Acceptance # 193-03-E 6-125 VAC 5 amps 6-25 VAC 1 amp WTUTAVs 125 VDC 0.5 amp Honeywell ®SILENT' I acir SK-MINIMON Intelligent Mini Monitor Mom The SK-MINIMON is an addressable monitor modules for use with the Honeywell Silent Knight fire alarm control panels (FACPs). The SK- MINIMON acts as an interface to contact devices, such as waterflow switches and pullstations.The SK-MINIMON supports Class B supervised wiring to the load device. Conventional4-w' smoke detectors can be monitored for alarm and trouble conditions The SK-MINIMON can be mounted in a sin ang junction box directly behind the monitored device. Its small size light weight allow it to be installed without rigid mounting requireme INSTALLATION The SK-MINIMON can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. FEATURES & BENEFITS • Single contact monitor • SK-Minimon support for Class B (Style B) contact monitor wiring • Small and lightweight size allows for flexible mounting options • Rotary address switches for fast installation • UL Listed • CSFM Listed • FM Approved el RESUM Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1 SK-MINIMON SK-MINIMON Technical Specifications RESUB Dec 09 2021 For a complete listin of all complian�aEf �F�vcEs � certifications, gi�T PHYSICAL ORDERING INFORMATION www.sitentknight.com. Dimensions:2.75" W x 1.3" H x0.5" D —> SK-MINIMON: Mini monitoring module Weight: 1.2 oz (37 g) Microsoft, Windows, and the Windows Logo are COMPATIBILITY registered trademarks ELECTRICAL The SK-MINIMON is compatible with the or trademarks of Operating Voltage: 15 - 32VDC following Honeywell Silent Knight fire alarm Microsoft Corporation. SLC Standbyand Alarm Current: 350 A µ control panels: Silent KnightSystem End -of -Line Resistance:47KS2 6820: Addressable fire alarm control panel p Sensor' and Honeywell' Initiating device circuit wiring resistance: 1,50052 6820EVS: Addressable fire alarm control panel are registered max with an emergency voice system. trademarks of Honeywell SLC loop resistance: 4052 max 6808: Addressable fire alarm control panel International, Inc. Wire Length: 6" min. —� 6700: Addressable fire alarm control panel This document is not 5700: Addressable fire alarm control panel intended to be used for ENVIRONMENTAL 5808: Addressable fire alarm control panel installation purposes. We tryto keep our product Operating Temperature: 32°F - 120°F (0°C - 5820XL: Addressable fire alarm control panel information up -to 49°C) 5820XL-EVS: Addressable fire alarm control panel date and accurate. We Humidity: l0%-93%non-condensing with an emergency voice system cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford, CT 06472 Doc 350133 1 Rev G 1 11/17 SILENT 13 800-328-0103 © 2017 Honeywell International Inc. EMGHT Honeywell ®SILENT' I acir SK-PULL-SA / SK-PULL-DA Intelligent Pull Stations I The SK-PULL-SA is a single action pull station requiring only one motion to activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel (FACP). Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating e alarm signal. The FACP recognizes each manual pull station by its ific address saving precious seconds in determining the location of an a INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-1/0 surface back box or semi -flush mounted on a standard single -gang with a minimum depth of 2.13"(5.40 cm) or double gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor' PN BG-TR) trim ring if the station is being semi -flush mounted. 1k FEATURES & BENEFITS • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets ADA requirement for 5 lbs maximum pull force to active • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Shell, door, and handle molded from durable LEXAN° SK-PULL-DA • Reliable analog communications for trouble -free operation • Braille text on station handle • Rotary address switches for fast installation RESU CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • UL Listed, including UL 38, Standard of Manually Actuated Signaling System • CSFM Listed • MEA Listed SK-PULL-SA / SK-PULL-DA Technical Specifications PHYSICAL ORDERING INFORMATION Dimensions: 5.5" H x4" W x 1.45" D (14 x 10.2 x —>SK-Pull-SA: Single Action Pull Station 3.7cm) SK-Pull-DA: Dual Action Pull Station Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station ACCESSORIES BG-TR: Optional trim ring. SB-1/0: Surface backbox, indoor/outdoor. * Unless otherwise noted, specifications apply to SK-Pull-SA and SK-Pull-DA COMPATIBILITY ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are Operating Voltage: 15 - 32VDC compatible with the following Honeywell Silent SLC Standby and Alarm Current: 350µA Knight fire alarm control panels: Wire Gauge: Up to 12AWG (3.1 mmz) 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel ENVIRONMENTAL with an emergency voice system. Operating Temperature: 320F - 120°F (0°C - 6808: Addressable fire alarm control panel 49°C)6700: Addressable fire alarm control panel Humidity: 10%- 93% non -condensing For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system Doc 350135 1 Rev E 111/17 © 2017 Honeywell International Inc. RESUB Dec 09 2021 For a complete listin of all complian�aEf �F�vcEs certifications, � . i1`lJT www.sitentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight°, System Sensor' and Honeywell' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up -to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. Honeywell SILENT' KMGNT Honeywell ®SILENT' IQVIGHT SK-RELAY Intelligent Relay Module The SK-RELAY is an addressable relay mod for use with Honeywell Silent Knight Series fire alarm control panels (FA T. The SK-RELAY allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK-RELAY contacts can be used for vir ly any normally open or normally closed application. Each SK-REL programmed with a unique signaling line circuit (SLC) loop address. W an event occurs that controls the SK-RELAY, the relay is triggere y the FACP. INSTALLATION The SK-RELAY mounts directly into a 4" sq# electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor' PN SMB500) is available from Silent Knight. FEATURES & BENEFITS • Two sets of Form C contacts • Rotary address switches for fast installation • Contacts are rated for a variety of amps (see Specifications) • Panelcontrolled status LED that flashes green in normal state and is solid red in alarm • Relay programming is completely flexible — can be mapped to zone conditions • Polling LED visible through the cover plate • SEMS screws for easy wiring • UL Listed Honeywell SLLI:1 I' I(N (Arl' SK-RELAY RESU Dec 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SK-RELAY Technical Specifications RESUB Dec 09 2021 For a complete listin of all complian�aEf �F�vcEs � certifications, gil�T PHYSICAL ORDERING INFORMATION www.sitentknight.com. 4.675" H x 4.275" W x 1.4" D — > SK-RELAY: Relay Module Shipping Weight: 6.3 oz (196 g) Microsoft, Windows, and ACCESSORIES. the Windows Logo are registered trademarks ELECTRICAL SM13500:4" Square Surface Mount Electrical Box or trademarks of Operating Voltage:15 - 32 VDC CB500:Module Barrier Microsoft Corporation. End -of -Line Resistance: Not used Silent Knight®, System SLC Standby &Alarm Current:.255mA max t?a COMPATIBILITY Sensor' and Honeywell' 24VDC (one communication every 5 sec with LED The SK-RELAY is compatible with the following are registered enabled) Honeywell Silent Knight fire alarm control panels: trademarks of Honeywell 6820: Addressable fire alarm control panel International, Inc. ENVIRONMENTAL 6820EVS: Addressable fire alarm control panel This document is not Operating Temperature: 320F - 120oF (OoC - with an emergency mass notification system. intended to be used for 490C) 6808: Addressable fire alarm control panel installation purposes. We Humidity: 10% - 93% non -condensing —> 6700: Addressable fire alarm control p panel keep our product infortryto information up -to RELAY CONTACT RATINGS 5700: Addressable fire alarm control panel date and accurate. We 3.OA 30VDC resistive 5808: Addressable fire alarm control panel cannot cover all specific applications or anticipate 0.9AC 11OVDCresistive 5820XL: Addressable fire alarm control panel all requirements. All 0.9A @ 125VAC resistive 5820XL-EVS: Addressable fire alarm control panel specifications are subject with an emergency mass notification system. to change without notice. 0.5A 125VAC inductive (PF=.35) C 0.7A C 75VAC inductive (PF = .35) For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products byvisiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell N o rthfo rd, CT 06472 Doc 3501271 Rev GI 11/17 SILENT 13 800-328-0103 © 2017 Honeywell International Inc. EMGHT RESUB 4,�� SY.STESORM Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151 °F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SIGNALING O L F M MEA 7300-1653:187 (outdoor strobes) LISTED approved 7125-1653:188 (horn strobes, S4011 (chimes, horn strobes, horns) APPROVED pp chime strobes) S3593 (outdoor and alert strobes) 3N,'F79 MEA452-05-E 7135-1653:189 (horns, chimes) 3c 09 ZUZ I TY OF EDMONDS LOPMENT SERVICES DEPARTMENT AIL 0 pf'r S y s t e m S e n s o ar SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40oF to 151 °F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including Candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. RESUB SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Dec 09 2021 SpecificatioNDS General DEVELOPMENT SERVICES DEPARTMENT SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit'°' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151 °F (-40oC to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1-W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 RESUB UL Current Draw Data Dec 09 2021 UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) NDS 8-17.5 Volts 16-33 Volts 8-17.5 Volts 1C)—BM\q6R1AMENT SERVICES IEWMENT Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current •Strobe,..Candela 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current •Strobe, DC Input High 16-33 Volts 135 150 177 Candela 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 wit 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output •8-17.5 candela ratings must be reduced in accordance with 16-33 24-Volt Nominal this table. S h S d Volts Volts Reverberant Anechoic StrobeOutput Listed Candela Candela rating at —40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 c Position oun Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 RESUB SpectrAlert Advance Diagrams Dee ^^ ''021 2.5" 3' Wall -Mount Horn Strobes IMP erproof Back Box Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Wall Horn Strobes -� P21FIK`t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK't 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK"t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK•t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK"t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK't Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK•t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK't Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: Add '-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM © to c System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensoccom or current product information, including the latest version of this data sheet. SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 AVDS01201 • 3/12