APPROVED BLD BLD2021-1572+Plumbing_Plan+11.17.2021_10.34.58_PM+2526346LEGEND
ACU
AIR CONDITIONING UNIT
EQUIPMENT
AFF
ABOVE FINISHED FLOOR
EF-1
TYPICAL EQUIPMENT DESIGNATION
AHJ
AUTHORITY HAVING JURISDICTION
(EXHAUST FAN SHOWN)
BHP
BRAKE HORSEPOWER
BTUH
BRITISH THERMAL UNIT PER
GENERAL
HOUR
C
COMMON
ARCHITECTURAL BACKGROUND
CAP
CAPACITY
(THIN LINE)
CC
COOLING COIL
CD
CONDENSATE DRAIN
NEW MECHANICAL WORK
CFM
CUBIC FEET PER MINUTE
(HEAVY LINE)
CLG
CEILING, COOLING
CO
CLEANOUT
- -
MATCHLINE OR PROPERTY LINE
COMB
COMBUSTION
SECTION INDENTIFICATION
CONT
CONTINUE, CONTROL
(DETAIL SIMILAR)
CONTR
COP
CONTRACTOR
COEFFICIENT OF PERFORMANCE
INDICATES DIRECTION OF CUTTING
PLANE
CWS
CHILLED WATER SUPPLY
A
LETTER INDICATES SECTION
CWR
CHILLED WATER RETURN
(N0. INDICATES DETAIL)
D
DIAMETER
M - 3 M-3
DB
DRY BULB, DECIBEL
SHEET # WHERE SECTION IS DRAWN
DEG
DEGREE
SHEET # WHERE SECTION IS TAKEN
DIM
DIMENSION
PIPING
DISCH
DISCHARGE
CD
CONDENSATE DRAINAGE
DN
DOWN
EAT
ENTERING AIR TEMPERATURE
G
NATURAL GAS - STANDARD PRESSURE
EFF
EFFICIENCY
MPG
NATURAL GAS - MEDIUM PRESSURE
EG
ENGINE GENERATOR
ELEC
ELECTRIC
WASTE (W)
EQUIV
EQUIVALENT
PW
PUMPED WASTE (PW)
EXH
EXHAUST
EXT
EXTERIOR, EXTERNAL
RL
RAIN LEADER (RL)
F
FAHRENHEIT
OL
OVERFLOW RAIN LEADER (OL)
FCU
FAN COIL UNIT
FLR
FLOOR
PRL
PUMPED RAIN LEADER (PRL)
FPM
FEET PER MINUTE
- - - - - - - - -
VENT (V)
FPS
FEET PER SECOND
G
GAS
-
COLD WATER (CW)
GAL
GALLONS
- -
HOT WATER, POTABLE, 120-F
GPM
GALLONS PER MINUTE
GWB
GYPSUM WALLBOARD
- - -
HOT WATER CIRCULATING HWC ,
( )
HD
HEAD
POTABLE, 1207
HORIZ
HORIZONTAL
- - 140E-
HOT WATER, POTABLE,
HP
HORSEPOWER
TEMPERATURE OTHER THAN 1207
HPU
HEAT PUMP UNIT
HOT WATER CIRCULATING (HWC), POTABLE,
HVAC
HEATING, VENTILATING, AND AIR
-140E-
TEMPERATURE OTHER THAN 1207
CONDITIONING
HWR
HOT WATER RETURN
IRR
IRRIGATION
HWS
HOT WATER SUPPLY
]
PIPE CAP
ID
INDIRECT DRAIN, INSIDE
DIAMETER
PIPE PLUG
IN
INCH
UNION
KW
KILOWATT
L
LONG, LENGTH
FLANGE
LB
POUND
GATE VALVE OR BALL VALVE
MBH
THOUSAND BTU PER HOUR
MECH
MECHANICAL
BALL VALVE
MCA
MINIMUM CIRCUIT AMPACITY
PRESSURE REDUCING VALVE (PRV)
MOCP
MAXIMUM OVER CURRENT
PROTECTION
BREAK IN PIPING OR DUCTWORK
MTD
MOUNTED
'".'!
CHECK VALVE
OD
OUTSIDE DIMENSION OR
DIAMETER, OVERFLOW DRAIN
BALANCING OR PLUG VALVE
OPNG
OPENING
BALANCING/MEASURING VALVE
P
PD
PUMP
PRESSURE DROP, PUMPED DRAIN
i ID
INDIRECT DRAIN, PIPE TO DRAIN
POC
POINT OF CONNECTION
GLOBE VALVE
PRV
PRESSURE REDUCING VALVE
BUTTERFLY VALVE
PSIG
POUNDS PER SQUARE INCH
GAUGE
WYE STRAINER
RD
ROOF DRAIN
WYE STRAINER WITH CAPPED HOSE
REF
REFERENCE
END SLOWDOWN VALVE
RPM
REVOLUTIONS PER MINUTES'
SCH
SCHEDULE
AUTOMATIC CONTROL VALVE,
SF
SQUARE FOOT
2-WAY
SR
SUDS RELIEF
AUTOMATIC CONTROL VALVE,
SS
STAINLESS STEEL, SANITARY
3-WAY
SEWER
SQ
SQUARE
2�ailD
RELIEF VALVE
TYP
TYPICAL
REDUCED PRESSURE BACKFLOW
UON
UNLESS OTHERWISE NOTED
RPBP
PREVENTER
V
VENT
VTR
VENT THRU ROOF
DOUBLE CHECK VALVE ASSEMBLY
W
WASTE, WATT, WIDE
DCVA
❑o
FLOOR DRAIN
HOSE BIBB
PIPE ALIGNMENT GUIDE
FLEXIBLE CONNECTION IN PIPING
PIPE SUPPORT
IPS
A
PIPE ANCHOR
9 PRESSURE GAGE
THERMOMETER
I P/T PRESSURE / TEMPERATURE TEST
PORT
HOC- VALVE STATION OR ASSEMBLY
PUMP
® WASTE/VENT RISER CALLOUT
0 CW/HW RISER CALLOUT
APPLICABLE CODES
THESE
DRAWINGS ARE
BASED ON THE FOLLOWING CODES:
-2015
INTERNATIONAL
BUILDING CODE (WITH WASHINGTON STATE AMENDMENTS)
-2015
INTERNATIONAL
MECHANICAL CODE (WITH WASHINGTON STATE AMENDMENTS)
-2015
UNIFORM PLUMBING CODE (WITH WASHINGTON STATE
AMENDMENTS)
-2015
INTERNATIONAL
FUEL GAS CODE (WITH WASHINGTON
STATE AMENDMENTS)
-2015
INTERNATIONAL
ENERGY CONSERVATION CODE (WITH
WASHINGTON STATE AMENDMENTS)
GENERAL NOTES
GENERAL NOTES - MECHANICAL
1. REFERENCE TO RELATED WORK: "REF" INDICATIONS DENOTE
WORK COVERED ELSEWHERE (ARCHITECTURAL, STRUCTURAL,
CIVIL, ELECTRICAL, LANDSCAPE, OR KITCHEN), OR ITEM BASED
ON A SPECIFIC MANUFACTURER'S DIMENSIONS (VERIFY).
2. ELECTRICAL CHARACTERISTICS: REFER TO ELECTRICAL
DRAWINGS FOR ELECTRICAL CHARACTERISTICS (VOLTAGES, ETC.)
OF MECHANICAL EQUIPMENT, UNLESS OTHERWISE INDICATED.
3. CODES: COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM
SHALL BE PER THE APPLICABLE BUILDING, MECHANICAL, ENERGY,
PLUMBING, FIRE, AND HEALTH CODES AND REGULATIONS AS ADOPTED
BY THE LOCAL AHJ.
4. PREPARE AND SUBMIT FOR REVIEW A SHOP DRAWING BASED ON
FINAL STRUCTURAL SHOP DRAWINGS FOR LOCATING AND ROUTING ALL
DUCTWORK, DAMPERS, EQUIPMENT, PIPING, ETC.
A. COORDINATE FLOOR AND BEAM PENETRATIONS WITH STRUCTURAL.
B. COORDINATE FINAL LOCATION AND ROUTING WITH CEILING,
LIGHTS, WALLS, FIRE SPRINKLER PIPING, AND OTHER TRADES WORK
C. INCLUDE ADDITIONAL OFFSETS, ELBOWS, ROUTING, EQUIVALENT
DUCT SIZING EXCHANGE, RELOCATING, ETC. AS REQUIRED FOR A
COMPLETE OPERATING MECHANICAL SYSTEM.
D. PROVIDE SHOP DRAWINGS AT NO ADDITIONAL COST TO THE
OWNER.
5. MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT
LOCATION OF ALL MECHANICAL EQUIPMENT WITHIN THE STRUCTURE.
6. ACCESS DOORS: COORDINATE WITH ARCHITECT AND LOCATE ALL
ACCESS DOORS ON SHOP DRAWINGS PRIOR TO BEGINNING OF
CONSTRUCTION. ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE
FIRE RATED. VERIFY ACCESS DOOR LOCATIONS WITH GENERAL
CONTRACTOR PRIOR TO BIDDING.
7. ROOF PENETRATIONS: SEE ARCHITECTURAL DRAWINGS FOR ROOF
CAP, ROOF CURB, ROOF DRAIN, AND VTR DETAILS.
8. EXPOSED PIPING: PROVIDE CHROME PLATING FOR EXPOSED
PIPING IN FINISHED ROOMS.
9. PENETRATIONS: PROVIDE ESCUTCHEON PLATES FOR EXPOSED
PIPING PENETRATIONS AND SHEET METAL FLASHING FOR EXPOSED
DUCTWORK PENETRATIONS.
10. SHAFT AND PLENUM CONNECTIONS: SEAL CONNECTIONS TO AIR
SHAFTS AIRTIGHT. PROVIDE AIRTIGHT SEAL AROUND
PENETRATIONS IN AIR PLENUMS.
11. LIGHT FIXTURE CLEARANCE: COORDINATE LOCATIONS OF
MECHANICAL WORK TO PROVIDE CLEARANCES OVER LIGHTING
FIXTURES FOR REMOVAL AND REPLACEMENT.
12. CABLE TRAYS: DUCTWORK AND PIPING INSTALLED ADJACENT TO
ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6"
ABOVE AND TO THE SIDE OF CABLE TRAYS.
13. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT:
VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT
ACCESS CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF
MECHANICAL WORK AND WORK OF OTHER TRADES TO PROVIDE
ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE.
COORDINATION REQUIREMENTS
1. IRRIGATION: COORDINATE WITH IRRIGATION CONTRACTOR FOR
THEIR WATER SUPPLY REQUIREMENTS AND LOCATIONS.
2. UTILITIES: COORDINATE WITH SITE UTILITY CONTRACTOR AND
CIVIL DRAWINGS FOR UTILITY CONNECTIONS AND EXTENSIONS.
3. ROOF DRAINAGE: COORDINATE WITH GENERAL CONTRACTOR FOR
ROOF DRAIN AND OVERFLOWS, SCUPPER DRAINS, AND CONDENSATE
DRAINS.
4. STORM DRAINAGE: VERIFY WITH GENERAL CONTRACTOR FOR
STORM DRAINAGE PRIOR TO BIDDING.
5. PLUMBING FIXTURES: COORDINATE WITH ARCHITECTURAL AND
OTHER TRADES EXACT LOCATION OF ALL PLUMBING FIXTURES.
6. PIPING: COORDINATE WITH STRUCTURAL FOR EXACT LOCATION
OF ALL STRUCTURAL FRAMING AND FOOTINGS AND FINALIZE THE
EXACT ROUTING OF ALL PIPES WITH STRUCTURAL AND AT THE SITE
PRIOR AND DURING THE CONSTRUCTION.
7. ADJUSTMENTS: ALL EQUIPMENT, MOTORS, FANS GAS BURNERS,
IGNITION DEVICES, DRIVES, ETC. SHALL BE ADJUSTED AND
BALANCED TO OPERATE AT SPECIFIED RATINGS AS REQUIRED FOR
THIS PROJECT SITE AND ACCOUNTING FOR ELEVATION ABOVE SEA
LEVEL.
8. APPROVALS: MECHANICAL AND PLUMBING EQUIPMENT SHALL BE
APPROVED FOR INSTALLATION IN THE PROJECT LOCATION AND SHALL
HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY,
POLLUTION, ENVIRONMENTAL, SEISMIC, ETC. CODES AND
REGULATIONS. THE CONTRACTOR SHALL COORDINATE WITH HIS
MANUFACTURE SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED
TO MEET THESE REQUIREMENTS IN HIS BID.
PIPING NOTES
1. DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR FLANGES AT
PIPING CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL
VALVES, AND OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR
MAINTENANCE.
2. REDUCERS: PROVIDE AS REQUIRED FROM LINE PIPE SIZE TO
EQUIPMENT, TRAP, COIL, AND CONTROL VALVE CONNECTION
SIZES.
3. OFFSETS: PROVIDE FOR BRANCH LINES TO EQUIPMENT.
4. DIELECTRIC UNIONS: PROVIDE AT CONNECTIONS OF DISSIMILAR
PIPE.
5. REFRIGERANT PIPING: PROVIDE SIZING & INSTALLATION IN
STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
6. CONDENSATE DRAIN: PROVIDE A P-TRAP FOR EACH HVAC UNIT
CONDENSATE PAN WITH PLUG TEES FOR CLEANING. CONDENSATE
DRAINS SHALL BE DISCHARGED TO AN INDIRECT WASTE OR
OUTSIDE.
PLUMBING NOTES
1. CONNECTIONS: PROVIDE PLUMBING FIXTURE CONNECTIONS TO
BUILDING WASTE, VENT, COLD WATER, AND HOT WATER SYSTEM
IN ACCORDANCE WITH DRAWINGS, MANUFACTURER'S
RECOMMENDATIONS, AND LOCAL CODES. CONNECT TO EACH
FIXTURE, EQUIPMENT, ETC. WITH ALL ACCESSORIES, VALVES,
VACUUM BREAKERS, REGULATORS, UNIONS, ETC. AS REQUIRED
AND AS RECOMMENDED BY THE MANUFACTURERS. REFER TO
PLUMBING FIXTURE CONNECTION SCHEDULE ON PLANS.
2. HOT AND COLD: WATER PIPING CONNECTION TO EACH FIXTURE
SHALL BE COLD WATER ON THE RIGHT HAND SIDE AND HOT WATER ON
THE LEFT HAND SIDE.
3. VENT STACKS: COORDINATE VENT STACK WITH HVAC EQUIPMENT
TO MAINTAIN MINIMUM 10' CLEARANCE FROM OUTSIDE AIR INTAKES.
4. CLEANOUTS: PROVIDE CLEANOUTS PER CURRENT UPC AND AS
REQUIRED BY LOCAL JURISDICTIONS. CLEANOUTS SHALL BE LOCATED
IN WALLS/FLOORS WHERE THEY ARE NOT HIGHLY VISIBLE. FLOOR
CLEANOUTS IN CARPETED AREAS TO BE FITTED WITH CARPET
INSERTS. LOCATIONS SHALL BE SUBMITTED TO ARCHITECT FOR
APPROVAL. NOTE: NOT ALL CLEANOUTS ARE SHOWN ON THE PLUMBING
DRAWINGS.
5. SUDS RELIEF: PROVIDE SUDS RELIEF IN ACCORDANCE WITH
CURRENT UPC.
6. SHUT -OFFS: SHUT-OFF VALVES SHALL BE INSTALLED IMMEDIATELY AHEAD
OF EACH WATER -SUPPLIED APPLIANCE AND IMMEDIATELY AHEAD OF EACH
SLIP JOINT OR APPLIANCE SUPPLY. REQUIRED SHUT-OFF VALVES SHALL
BE ACCESSIBLE. EXCEPTION: PROVIDE SCREWDRIVER STOPS AT
BATH/SHOWERS.
7. TRAP ARMS: PROVIDE TRAP ARMS SUCH THAT THE MAXIMUM
LENGTH WILL NOT EXCEED CODE REQUIREMENTS.
8. ADA INSULATION: AT PLUMBING PIPING EXPOSED UNDER
LAVATORIES, INSULATE THE EXPOSED PIPING AND TRAPS WITH
PRODUCT SPECIFICALLY DESIGNED FOR THIS APPLICATION MEETING
ADA REQUIREMENTS. PROVIDE HANDI-LAV GUARD OR EQUIVALENT.
OFFSET P-TRAPS TO CLEAR WHEELCHAIR ACCESS.
9. FREEZE PROTECTION: WATER PIPING SHALL BE INSTALLED ON
THE WARM SIDE OF INSULATION. ROUTE NO WATER PIPING IN ATTIC
SPACE. HEAT TAPING IS NOT ACCEPTABLE.
10. GAS EQUIPMENT: GAS EQUIPMENT SHALL BE INSTALLED PER
EQUIPMENT LISTINGS, LOCAL CODES, AND NFPA.
11. FIREPLACES: EACH FIREPLACE TO HAVE BRASS KEYED WALL
SHUT-OFF VALVE. ALL GAS EQUIPMENT TO HAVE UNION, DIRT LEG,
AND GAS COCK.
12. WATER HAMMER ARRESTERS: PROVIDE AT THE END OF HOT AND
COLD WATER LINES SERVING TWO OR MORE FIXTURES; SIZE IN
ACCORDANCE WITH PLUMBING AND DRAINAGE INSTITUTE (PDI)
REQUIREMENTS. WATER HAMMER ARRESTORS ARE REQUIRED FOR
QUICK CLOSING VALVES, SUCH AS LAUNDRY WASHERS, FLUSH
VALVES (PUBLIC TOILETS), ETC. MODEL PPP MIL-D-82036
OR EQUAL. VERIFY SIZE BEFORE ORDERING.
13. TRAP PRIMERS: PROVIDE TRAP PRIMERS AND PIPING FOR
DRAINS AND FLOOR SINKS. ARRANGE PIPING TO ACHIEVE EQUAL
FLOW TO EACH DRAIN AND FLOOR SINK FOR TRAP PRIMERS SERVING
MULTIPLE DRAINS AND FLOOR SINKS.
14. PIPE INSULATION: INSULATE ALL HOT WATER PIPING PER WSEC.
MINIMUM PIPE INSULATION THICKNESS
DOMESTIC HOT WATER
FLUID DESIGN
CONDUCTIVITY RANGE
OPERATION TEMP.
'F
BTU*IN./(H*FT2*.F)
NOMINAL PIPE SIZE
RANGE,
1-1/2
4 TO
< 1
<1-1 2
TO <4
<8
> 105
0.22 - 0.27
1.0
1.0
1.5
1.5
Work
City Of Edmonds
Building Department
PLUMBING
Address 23830 EDMONDS WAY
Owner EDMONDS CROSSING
-------------------------
Approved Date 12/02/2021
Building Official Eric, Cvwf'e r
Permit Number
BLD2021-1572
DRAWINGS ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION,
TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL
NOT BE SCALED FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL
DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD
INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND
INSTALLATION REQUIREMENTS. PROVIDE DUCTWORK, CONNECTIONS,
ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY FOR A COMPLETE
SYSTEM.
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
- -pPRO\
PLANS MIU
ON JOB ;
PRE -CON MEETING
CONTRACTORS SHALL ATTEND A PRE -CONSTRUCTION MEETING WITH THE ENGINEER FOR THE PURPOSE
OF REVIEWING THE WORK PRIOR TO ORDERING ANY EQUIPMENT OR PERFORMING ANY WORK. THE
MEETING SHALL BE LOCATED AT THE PROJECT SITE ON A DATE AND TIME TO BE MUTUALLY AGREED.
THE MEETING WILL BE A WORKING SESSION. THE MEETING WILL BE FACILITATED BY THE ENGINEER
AND THE AGENDA WILL INCLUDE A DETAILED REVIEW OF THE PLANS AND SPECIFICATIONS, CROSS
CHECK WITH OTHER TRADES FOR COORDINATION ISSUES, REVIEW OF PROPOSED PRODUCTS, REVIEW
OF PLANNED MEANS AND METHODS, AND ON -SITE INVESTIGATION OF FIELD CONDITIONS RELATIVE
TO EXISTING CONDITIONS THAT COULD AFFECT THE WORK. PERSONS ATTENDING THE MEETING
SHALL BE KNOWLEDGEABLE OF THE PROJECT AND SHALL BE THE SPECIFIC PERSONS INTENDED
TO CONTINUE WITH THE PROJECT THROUGH TO COMPLETION. IF REQUIRED, REVISED PLANS WILL BE
ISSUED THROUGH OFFICIAL CHANNELS. CHANGES IN THE BID PRICE WILL BE DISCUSSED, BUT NO
CHANGE ORDERS WILL BE ISSUED UNLESS PROCESSED THOUGH OFFICIAL CHANNELS. IT SHALL BE
UNDERSTOOD THAT THE ENGINEER HAS NO AUTHORITY TO ISSUE CHANGE ORDERS.
THE FOLLOWING TRADES SHALL BE REPRESENTED FOR THE MINIMUM
TIME INDICATED:
MECHANICAL SHEET METAL 2 HOURS
PLUMBING/PIPING 2 HOURS
ELECTRICAL 2 HOURS
GERERAL CONTRACTOR ALL SESSIONS
PIPE MATERIALS
1. WATER DISTRIBUTION PIPING: CPVC.
(PEX UP TO 2", CVPC 2y2" AND LARGER)
2. WASTE & VENT PIPING: CAST IRON, ABS, OR PVC.
3. CONDENSATE DRAIN PIPING: PVC, ABS, OR TYPE M COPPER.
4. WATER SERVICE PIPING: CPVC.
NOTE: CONTRACTOR SHALL INDICATE THE TYPE OF PIPE
MATERIALS INCLUDED IN THEIR BID. ALTERNATE PIPE
MATERIALS SHALL BE SUBMITTED TO THE OWNER AND
ENGINEER FOR APPROVAL PRIOR TO INSTALLATION.
DRAWING INDEX
DWG
DESCRIPTION
INCLUDED IN
SET
w
Cn cV
CV
a CD
P000
LEGEND GENERAL NOTES & DRAWING INDEX
•
P001
SCHEDULES
•
P002
CALCULATIONS
•
P200
UNDERSLAB PLAN
•
P201
FIRST FLOOR PLAN
•
P202
SECOND FLOOR PLAN
•
P203
THIRD FLOOR PLAN
•
P204
ROOF PLAN
•
P300
ENLARGED UNIT PLANS
•
P400
WASTE & VENT RISER DIAGRAMS
•
P401
WATER SUPPLY RISER DIAGRAMS
•
P402
DETAILS & DIAGRAMS
•
P403
DETAILS & DIAGRAMS
•
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
EMERALD CITY
ENGINEERS, INC
21 705 Highway 99
2Lynnwood, W98036
00TEL:425-741
PROJECT TITLE / PROJECT ADDRESS
New Construction
for
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
°ooa❑❑❑0000
op��%. of WASy •°°••.. � p
o� c °
O°
OZQ�oo0oo0�°O
10-20-21
SHEET TITLE
LEGEND, GENERAL
NOTES, &
DRAWING INDEX
SHEET NUMBER
POOO
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOLILET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\POOO.DWG 11-08-2021 12:30
DOMESTIC WATER HEATER SCHEDULE - ELECTRIC
EQUIP
NO.
SERVICE
STORAGE,
GALLONS
ELEMENT KW
ELECTRICAL
STORAGE,
DEG. F.
EVERGREEN STANDARD
BASIS OF DESIGN
MAX STANDBY
LOSS (BTUH)
ENERGY
FACTOR
WH-1
RESIDENTIAL UNITS
50
4.5
208V/1 P
120
N/A
0.93
RHEEM PROE50 T2 RH95 (1)(2)
WH-2
RESIDENTIAL UNITS
47
4.5
208V/1 P
120
N/A
0.93
RHEEM PROE47 S2 RH95 (1)(2)
NOTES (1) PROVIDE WATER HEATER STAND & DRAIN PAN FOR ALL UNITS. REFER TO DETAIL 6 ON P4.04.
EXPANSION TANK SCHEDULE
EQUIP
N0.
SERVICE
CAPACITY,
GALLONS
TANK SIZE, IN
BASIS OF DESIGN
DIA.
HEIGHT
ET-1
RESIDENTIAL WATER HEATERS
4.4
11
15
AMTROL THERM—X—TROL ST-12
PLUMBING PPE INSULATION SCHEDULE
SERVICE
MATERIAL
THICKNESS
FIELD APPLIED
VAPOR RETARDER
JACKET
REQUIRED
DOMESTIC, HOT AND RECIRCULATED HOT WATER, OPERATING
Y2"—y4" PIPE: 1"
TEMPERATURE: 105 TO 140 DEG F. (NOTE: THIS APPLIES
MINERAL —FIBER WITH JACKET
1 "-1 y2" PIPE: 1 y2"
NONE
YES
TO ALL HOT WATER AND RECIRCULATED HOT WATER
PIPING).
2"-6" PIPE: 2"
HORIZONTAL RAINWATER CONDUCTORS LOCATED IN
MINERAL —FIBER OR CELLULAR
ALL SIZES: 1 /2"
FOIL AND PAPER
YES
CONDITIONED SPACES.
GLASS, WITH JACKET
ROOF DRAIN BODIES
MINERAL —FIBER OR CELLULAR
1
NONE
YES
GLASS WITH JACKET
EXPOSED SANITARY DRAINS AND DOMESTIC WATER
"LAV—GUARD" AS
N/ A
PVC P—TRAP AND
NO
SUPPLIES AND STOPS FOR FIXTURES FOR THE DISABLED.
MANUFACTURED BY TRUEBRO
SUPPLY COVERS
SCHEDULES
PLUMBING FIXTURE SCHEDULE (1)
EQUIP
NO.
FIXTURE TYPE
SERVICE SIZE (INCHES)
MANUFACTURER
MODEL
EVERGREEN STANDARD
FLOWRATE (MAXIMUM)
COMMENTS
CW
HW
W
V
WC-1
WATER CLOSET
1 /2
—
3
2
WATER CLOSET
GERBER
21-902
1.28 GPF
SEAT
BEMIS
500EC
— — —
ROUND TOILET SEAT WITH COVER,
CLOSED FRONT
LAV-1
LAVATORY
1 /2
1 /2
2
1-1/2
LAVATORY
REGAL
L-1290
— — —
DROP IN
FAUCET
CLEVELAND FAUCET GROUP
47711 L
1.2 GPM
BATH-1
BATH/SHOWER
3/4
3/4
2
1-1/2
BATHTUB
FIBER—FAB
10OLSC
— — —
PROVIDE ALL REQUIRED VALVES,
NOTE 2
TRIM KIT
CLEVELAND FAUCET GROUP
40311
— — —
DRAIN, ETC. AS REQUIRED FOR A
COMPLETE SYSTEM
SHOWERHEAD
1.75 GPM
SH-1
SHOWER
3/4
3/4
2
1-1/2
SHOWER ENCLOSURE
FIBER—FAB
63FWBF
— — —
PROVIDE ALL REQUIRED VALVES,
NOTE 2
TRIM KIT
CLEVELAND FAUCET GROUP
40315
— — —
DRAIN, ETC. AS REQUIRED FOR A
COMPLETE SYSTEM
SHOWERHEAD
1.75 GPM
SHOWER DRAIN
FIBER—FAB
V140NC
---
THRESHOLD
FIBER—FAB
ERT
---
SK-1
KITCHEN SINK
1 /2
1 /2
2
1-1/2
SINK
DAYTON
DSE23322
---
FAUCET
CLEVELAND FAUCET GROUP
41611
1.5 GPM
PROVIDE 1.5 GPM AERATOR
WB-1
CLOTHES WASHER BOX
3/4
3/4
2
1-1/2
CLOTHES WASHER BOX
SPECIALTY PRODUCTS
OB-210
---
FS-1
PER DWGS
—
—
NOTE 6
FLOOR SINK
JAY R. SMITH
3140
— — —
NOTE 3
FD-1
PER DWGS
—
—
NOTE 6
FLOOR DRAIN
JAY R. SMITH
2O05—A
— — —
NOTE 3
HB-1
ROOF HYDRANT
3/4
—
—
—
WOODFORD
SRH—MS
N/A
OR EQUAL
WCO
PER CODE
—
—
—
—
WALL CLEANOUT
JAY R. SMITH
4402
— — —
OR JOSAM, WADE, ZURN
FCO
PER CODE
—
—
—
—
FLOOR CLEANOUT
JAY R. SMITH
4020
— — —
OR JOSAM, WADE, ZURN
NOTES: (1)
CONTRACTOR SHALL CONFIRM MAKE, MODEL,
FINISH WITH OWNER PRIOR TO ORDERING.
(2)
PROVIDE
COMPLETE INTEGRAL BACKING AT ALL TUBS & SHOWERS.
(3)
PROVIDE
MUD SET FOR DRAINS LOCATED AT
TILE FLOORS.
(4)
PROVIDE
REMOVABLE THRESHOLD FIBER—FAB
MODEL ERT.
(5)
ADA GRAB
BARS AND SEAT TO BE SHIPPED
LOOSE AND TURNED OVER TO OWNER.
(6)
SIZE PER
PLANS.
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
EMERALD CITY
ENGINEERS, INC
21 705 Highway 99
Lynnwood, WA 98036
TEL: 425-741-1200
PROJECT TITLE / PROJECT ADDRESS
New Construction
for
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
Io-20-21
SHEET TITLE
SCHEDULES
SHEET NUMBER
Pool
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOULET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P001 SCHEDULES.DWG 11-08-2021 12:30
FIXTURE UNIT MATRICES
WATER SUPPLY
EMERALD GI Y ENG14EERS Edmonds Crossing
21705 HIGHWAY 99 2392-001
LYNNWOOD WA,98036 CG
10/5/2021
1►►7[�IN�F.�llly�lllll�l►�IIII.rII♦]I[�
11:11�`1'►r1117 it �:nr1:I:t�I�:?I
FXTURE
DFU
EACH
QTY
EACH
NUMBER OF ROOMS
1ST 2ND 3RD
TOTAL QTY
OF FDCLURES
TOTAL FIXTURE
UNITS
LAVATORY
1
1
3 2 2
7
7
WATER CLOSET
3
1
3 2 2
7
21
SNK
2
1
3 2 2
7
14
BATH
2
1
3 2 2
7
14
CLOTHES WASHER
3
1
3 2 2
7
21
WATER HEATER HUB DRAIN
3
1
3 2 2
7
21
98
UNITS WITH 2 BATHROOM S
FXTURE
DFU
EACH
QTY
EACH
NUMBER OF ROOMS
1ST 2ND 3RD
TOTAL QTY
OF FDCLURES
TOTAL FIXTURE
UNITS
LAVATORY
1
2
1 1 1
6
6
WATER CLOSET
3
2
1 1 1
6
18
SNK
2
1
1 1 1
3
6
BATH
2
2
1 1 1
6
12
CLOTHES WASHER
3
1
1 1 1
3
9
WATER HEATER HUB DRAIN
3
1
1 1 1
3
9
60
TOTAL FIX.TUE UNITS: 158 FIXTURE UNITS
HOT WATER SUPPLY
EMERALD GITY ENG14EERS Edmonds Crossing
21705 HIGHWAY 99 2392-001
LYNNWOOD WA,98036 CG
10/5/2021
SUPPLY FIXTURE UNIT CALCULATIONS
UNTS VNTH 7 BATHROOM
IFDCTURE
WSFU
EACH
QTY
EACH
NUMBER OF ROOMS
1ST 2ND 3RD
TOTAL QTY
OF FIXTURES
TOTAL FIXTURE
UNITS
LAVATORY
1
1
3 2 2
7
7
WATER CLOSET
2.5
1
3 2 2
7
17.5
SNK
1.5
1
3 2 2
7
10.5
BATH
4
1
3 2 2
7
28
CLOTHES WASHER
4
1
3 2 2
7
28
91
!12 MIRWAIAN:I'A:nr1:I:-PIS:?IE'
IFDCTURE
WSFU
EACH
QTY
EACH
NUMBER OF ROOMS
1ST 2ND 3RD
TOTAL QTY
OF FIXTURES
TOTAL FIXTURE
UNITS
LAVATORY
1
2
1 1 1
6
6
WATER CLOSET
2.5
2
1 1 1
6
15
SINK
1.5
1
1 1 1
3
4.5
BATH
4
2
1 1 1
6
24
CLOTHES WASHER
4
1
1 1 1
3
12
61.5
1[01r►10a 114u1all 211 ibYA711111111 a 114Ill aall 211 AI
WATER MAINS S0NG
Emerald City Engineers, Inc.
21705 Highway 99
Lynnwood, WA 98036
Project Name: Edmonds Crossing
Project Number: 2392-001
Edited By: CG
Edit Date: 10/13/2021
SIZING IS PER 2015 UPC
WATER SUPPLY PIPE SIZING CALCULATION FORM
UTILITY SUPPLY WATER PRESSURE:
OBTAIN FROM CIVIL OR LOCAL UTILITY COMPANY.
WATER METER LOSS:
TYPICALLY 3-8 PSI.
BACKFLOW PREVENTER LOSS:
TYPICALLY 5-10 PSI.
STATIC LIFT:
REQUIRED MINIMUM PRESSURE AT
FURTHEST UNIT WATER HEATER:
PRESSURE AVAILABLE TO
OFFSET FRICTION LOSSES:
PIPING SYSTEM LENGTH FROM
SERVICE TO FURTHEST FIXTURE:
FITIING ALLOWANCE:
MAXIMUM FRICTION LOSS FACTOR:
SELECTED FRICTION LOSS FACTOR:
MAX CW & HW VELOCITY 8 FPS FOR 112" - 2".
MAX CW & HW VELOCITY 5 FPS FOR PIPES 2-112" & LARGER.
54.0 PSI STATIC PRESSURE
3.0 PSI
5.0 PSI
25 FEET = 10.8 PSI
34.0 PSI
1.2 PSI
98.0
FEET
49.0
FEET
0.8
PSI/100 FT
0.8
PSI/100 FT
SUPPLY
PIPE SIZING SCHEDULE
FLUSH TANK CW
HOT WATER
FLUSH VALVE CW
PIPE SIZE
FLOW,
VEL.
FIXTURE
FLOW,
VEL.
FIXTURE
FLOW,
VEL.
FIXTURE
IN
GPM
FPS
UNITS
GPM
FPS
UNITS
GPM
FPS
UNITS
1/2"
0.7
1.3
---
0.7
1.3
---
0.7
1.3
---
3/4"
2.0
1.6
�4.O
2.0
1.6
�4.
�3.9
1.6
1"
3.9
1.9
3.9
1.9
1.9
---
1-1/4"
6.6
2.1
7.5
6.6
2.1
7.5
6.6
2.1
---
1-1/2"
10.3
2.4
13.5
10.3
2.4
13.5
10.3
2.4
---
2"
20.5
2.8
31.0
20.5
2.8
31.0
20.5
2.8
---
2-1/2"
42.8
3.3
98.0
42.8
3.3
98.0
42.8
3.3
32.5
3"
77.9
3.9
263.5
77.9
3.9
263.5
77.9
3.9
139.5
4"
161.3
4.6
700.0
161.3
4.6
700.0
161.3
4.6
640.0
6"
398.7
5.0
2655.0
398.7
5.0
2655.0
398.7
5.0
2655.0
WATER RUNOUT SIZING
Enter Your System Parameters for Each Table:
A B C
40 120 40 Water Size Table Temperature(F)
8 8 8 ] Max. Velocity Per Water Temp (ft./sec)
FT FT FV WSFU Predominant Fixture Curve
Choose the code that your state or local AHJ has adopted.
UPC State specific codes are only listed if the fixture unit to
gpm conversion differs from a model code.
Water Size Chart for Uponor AquaPEX
Uponor AquaPEX Water Size Table
Uponor AquaPEX Water Size
Table
Uponor AquaPEX Water Size Table
UPC -Flush Tank
UPC -Flush Tank
UPC - Flush Valve
100% Water @ 40°F
100% Water @ 1207
100% Water @ 40'F
16.666 PSI/100R.
16.666 PSI/300ft.
16.666 PSI/100ft.
Max. Velocity=8k./sec.
Max. Velocity =BftJsec.
Max. Velocity=8ft/sec
SAMTARY
Pipe WSFU Velocity GPM
Size Range (ft./sec.)
Pipe
Size
WSFU Velocity
Range MA-)
GPM
Pipe
Size
WSFU Velocity
Range MA-)
GPM
3/8" 0--0 4.60 1.38
1/2" 1--3 5.80 3.20
318"
1/2"
0--0 5.40
1--3 6.70
1.62
3.70
3/8"
1/2"
0--0 4.60
0--0 5.80
L38
3.20
.LDCTTYEN33N EM
314" 4--10 7.40 8.16
314"
4--11 8.00
8.82
34'
1--1 7.40
8.16
2170G HK3il_i,9i�r88
LL�JL�;J�'rTrTl�1F5h6u .7,7
^^�-
1" 11--20 8.00 14.55
1"
12--20 8.00
14.55
1"
2--2 8.00
14.55
4 W-5
GG
11/4' 21--33 3.00 21.76
11/4"
21--33 8.00
21.76
11/4"
3--4 8.00
21.76
19 1
1 1/2" 34 -- 54 8.00 30.31
1 V2"
34 -- 54 8.00
30.31
l ll2"
5 --13 8.00
30.31
2" 55--134 8.00 51.97
2"
55--134 8.00
51.97
2"
14--51 8.00
51.97
Vtiia,."TE WTLRE UNIT CALCULAT ON5
21/2" 135--270 8.00 79.21
21/2"
135--270 8.00
79.21
21/2"
52--144 8.00
79.21
3" 271-- 443 8.00 112.63
3"
271-- 443 8.00
112.63
3"
145 -- 313 8.00
112.63
UNITS NTH 1 BATHIROM
FKTUFE
DFU
EACH
OTY
EACH
NI-PBEROFFE0CM
;5T 21ND 3FD
IOTA L OTY
OFFIXTUIFES
TOTAL FACTUIFE
LNITS
LAVATORY
1
1
3
2
2
7
7
VATBRC1_r-= SET
3
1
3
2
2
7
21
SINK
2
1
3
2
2
7
14
EATH
2
1
3
2
2
7
14
CIOTHES VO,SHER
3
1
3
2
2
7
21
,TER HP TER HLB BAN
3
1
3
2
2
7
21
SB
UNIT 5 NTH 2 BATHFUON 5
FACTUFE
DFU
EACH
QTY
EACH
NLMBEPCFRDCMS
1ST 2ND 3RD
IOTA L QTY
OFFIXTI-FES
TOTAL FPCTUIF�
UNITS
LAVATCFd(
1
2
1
1
1
B
B
VY,TERCLCGL7
3
2
1
1
1
B
18
SINK
2
1
1
1
1
3
6
BATH
2
2
1
1
1
B
12
9-OTHES VO,SHER
3
1
1
1
1
3
9
VY,TER HEis TER HLB BAN
3
1
1
1
1
3
9
00
PUBLIC SPACES
FACTUIFE DFU TOTAL QTY TOTAL FKTUFEI
EACH tST 2ND. 3RD. OF RXnl;ES UNITS
FLCCR DRAN 2 •D •D 2
FLCCRS W 8 •D •D 5
TOTAL FKTUE-UNITS: - n5 FACTURE LHITS
Calculate
212
uponor Pipe sizing calculator
Accurate pipe sizing for your project
We understand the importance of precise calculations. Use our pipe sizing calculator for quick, accurate sizing of your
plumbing, hydronic or radiant piping project.
PLUMBING HYDRONIC
Provide the following criteria and then click calculate below.
Enter Your Domestic Water Supply Parameters
34 PressureAvailab leatBuilding
25 Min. Fixture Working Pressure
Static Loss - System Height (ft.)
Additional Component Loss
Enter Your Piping Supply Information
16 Longest Run to Fixture(ft.)
50 Fitti ng Allowance (% of number above)
RADIANT PIPE HEAT LOSS
Email Report
Calculation:
+ 34.00 PSI
- 25.00 PSI
0.00 x 0.433 - 0.00 PSI
5.00 PSI
Available Pressure For Friction Loss = 4.00 PSI
Calculation:
+ 16.00 FT
+ 6.00 FT
Total Developed Length = 24.00 FT
Friction Loss Rate Per Foot (Friction Loss/TDL) = 0.166 PSI/FT
Friction Loss Rate per 100 Feet (Friction Loss /TDL100) = 16.666 PSI/SOOFT
112
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
rrn
EMERALD CITY
ENGINEERS, INC
21 705 Highway 99
Lynnwood, WA 98036
TEL: 425-741-1200__f I
PROJECT TITLE / PROJECT ADDRESS
New Construction
for
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
p❑❑❑p00,
bfi WASy °°°•.. p
o� ❑
ooF°•��.........•" \moo
�1a0000��°O
SHEET TITLE
CALCULATIONS
SHEET NUMBER
P002
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOULET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P002 CALCULATIONS.DWG 11-08-2021 12:29
C(
UNDERSLAB PLAN Z.
SCALE: 1 /4" = 1'-0"
W
NI nTF7-
0 = WASTE/VENT IDENTIFICATION
(RISER "5", FOR EXAMPLE).
REFER TO DWG P400, DETAIL 1
FOR RISER DETAILS/PIPE
SI ZES.
WASTE PIPING NOTES:
1. HORIZONTAL WASTE PIPING SHALL SLOPE AT %"
PER L.F. MINIMUM FOR ALL PIPES 4" AND LARGER.
2. PROVIDE CLEANOUTS PER CURRENT CPC AND AS
REQUIRED BY LOCAL JURISDICTIONS. CLEANOUTS
SHALL BE PROVIDED AT 100 FOOT INTERVALS &
EACH AGGREGATE HORIZONTAL CHANGE OF
DIRECTION EXCEEDING 135 DEGREES.
CLEANOUTS SHALL BE LOCATED IN WALLS/
FLOORS WHERE THEY ARE NOT HIGHLY VISIBLE.
FLOOR CLEANOUTS IN CARPETED AREAS TO BE
FITTED WITH CARPET INSERTS. LOCATIONS
SHALL BE SUBMITTED TO ARCHITECT FOR
APPROVAL.
NOTE: NOT ALL CLEANOUTS ARE SHOWN ON THE
PLUMBING DRAWINGS.
WASTE PIPING NOTES:
1. HORIZONTAL WASTE PIPING 4" AND LARGER
SHALL SLOPE AT %4" PER L.F. MINIMUM.
MAXIMUM FIXTURE UNITS FOR PIPING IS
AS FOLLOWS:
4" PIPE: 216 FU'S
6" PIPE: 720 FU'S
8" PIPE: 2640 FU'S
PIPING SMALLER THAN 4" SHALL SLOPE %4"
PER L.F. MINIMUM.
'SS POC
=396.35'
DEFER TO CIVIL FOR CONTINUATION)
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
rrn
EMERALD CITY
ENGINEERS, INC
21 705 Highway 99
Lynnwood, WA 98036
TEL:425-741-1200 it
PROJECT TITLE / PROJECT ADDRESS
New Construction
for
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
10-20-21
SHEET TITLE
UNDERSLAB
PLAN
SHEET NUMBER
P200
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOLILET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P200.DWG 11-08-2021 12:29
i
i
FIRST FLOOR PLAN Z
SCALE: 1 /4" = 1'-0"
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
rrn
N OTE:
05 = WASTE/VENT IDENTIFICATION
(RISER "5", FOR EXAMPLE).
FOR EXAMPLE.
REFER TO DWG P400, DETAIL 1
EMERALD CITY
LOOR NUMBER.
FOR RISER DETAILS/PIPE
SIZES.
ENGINEERS, INC
AMPLE, REFER TO
A
0 = WATER SUPPLY RISER
21705 Hi9
Lynnwood,, WWAA 98036
500.
�� ��
IDENTIFICATION (RISER "A", FOR
TEL:425-741-1200
it
EXAMPLE). REFER TO DWG P401,
DETAIL 1 FOR RISER
DETAILS/PIPE SIZES.
PROJECT TITLE / PROJECT ADDRESS
FLAG NOTE:
=PIPES TO BE INSTALLED
ON THE WARM SIDE
OF THE WALL INSULATION.
WASTE PIPING NOTES:
1. HORIZONTAL WASTE PIPING SHALL SLOPE AT %"
PER L.F. MINIMUM FOR ALL PIPES 4" AND LARGER.
2. PROVIDE CLEANOUTS PER CURRENT CPC AND AS
REQUIRED BY LOCAL JURISDICTIONS. CLEANOUTS
SHALL BE PROVIDED AT 100 FOOT INTERVALS &
EACH AGGREGATE HORIZONTAL CHANGE OF
DIRECTION EXCEEDING 135 DEGREES.
CLEANOUTS SHALL BE LOCATED IN WALLS/
FLOORS WHERE THEY ARE NOT HIGHLY VISIBLE.
FLOOR CLEANOUTS IN CARPETED AREAS TO BE
FITTED WITH CARPET INSERTS. LOCATIONS
SHALL BE SUBMITTED TO ARCHITECT FOR
APPROVAL.
NOTE: NOT ALL CLEANOUTS ARE SHOWN ON THE
PLUMBING DRAWINGS.
WASTE PIPING NOTES:
1. HORIZONTAL WASTE PIPING 4" AND LARGER
SHALL SLOPE AT %4" PER L.F. MINIMUM.
MAXIMUM FIXTURE UNITS FOR PIPING IS
AS FOLLOWS:
4" PIPE: 216 FU'S
6" PIPE: 720 FU'S
8" PIPE: 2640 FU'S
PIPING SMALLER THAN 4" SHALL SLOPE %4"
PER L.F. MINIMUM.
New Construction
for
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
10-20-21
SHEET TITLE
FIRST
FLOOR
PLAN
SHEET NUMBER
P201
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOLILET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P201.DWG 11-08-2021 12:29
SECOND FLOOR PLAN Z
SCALE: 1 /4" = 1'-0"
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
rrn
N OTE:
05 = WASTE/VENT IDENTIFICATION
(RISER "5", FOR EXAMPLE).
<1 FOR EXAMPLE.
REFER TO DWG P400, DETAIL 1
EMERALD CITY
FLOOR NUMBER.
FOR RISER DETAILS/PIPE
SIZES.
ENGINEERS, INC
XAMPLE, REFER TO
A
0 = WATER SUPPLY RISER
9
Lynnwood, WA 21705 Hi, WA036
'300.
��
IDENTIFICATION (RISER "A", FOR
TEL:425-741-1200
EXAMPLE). REFER TO DWG P401,
-fl
DETAIL 1 FOR RISER
DETAILS/PIPE SIZES.
PROJECT TITLE / PROJECT ADDRESS
New Construction
for
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
Io--0-21
SHEET TITLE
SECOND
FLOOR
PLAN
SHEET NUMBER
P202
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOULET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P202.DWG 11-08-2021 12:29
1 FOR EXAMPLE.
'LOOR NUMBER.
,AMPLE, REFER TO
300.
—J
THIRD FLOOR PLAN Z
SCALE: 1 /4" = 1'-0"
NI nTF-•
05 = WASTE/VENT IDENTIFICATION
(RISER "5", FOR EXAMPLE).
REFER TO DWG P400, DETAIL 1
FOR RISER DETAILS/PIPE
SI ZES.
OA = WATER SUPPLY RISER
IDENTIFICATION (RISER "A", FOR
EXAMPLE). REFER TO DWG P401,
DETAIL 1 FOR RISER
DETAILS/PIPE SIZES.
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
rrn
EMERALD CITY
ENGINEERS, INC
21 705 Highway 99
Lynnwood, WA 98036
TEL:425-741-1200 it
PROJECT TITLE / PROJECT ADDRESS
New Construction
for
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
of
a � '
'pFG/ R
4°° \
000�g00 AL 2%\ <
io-20-21
SHEET TITLE
THIRD
FLOOR
PLAN
SHEET NUMBER
P203
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOLILET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P203.DWG 11-08-2021 12:29
ROOF PLAN Z
SCALE: 1 /4" = 1'-0"
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
rrn
EMERALD CITY
ENGINEERS, INC
21 705 Highway 99
2Lynnwood, W98036
00TEL:425-741
PROJECT TITLE / PROJECT ADDRESS
New Construction
for
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
p�� : ° ° of ASy •°°•. C
a '
'pFG/ R
\
000�000000��<
io" 0-21
SHEET TITLE
ROOF
PLAN
SHEET NUMBER
P204
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOULET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P204.DWG 11-08-2021 12:28
SHEET NOTES:
1. REFER TO FLOOR PLANS FOR WASTE & VENT RISER IDENTIFICATIONS
AND REFER TO RISER DIAGRAMS FOR WASTE & VENT RISER SIZING.
FLAG NOTES:
1� = REFER TO DETAIL 6 ON P4.04 FOR WATER HEATER PIPING
DIAGRAM.
WATER PIPE SIZING TABLE
FIXTURE
HOT
WATER
COLD
WATER
LAV-1 (0.75 FU)
Y2"
h"
WC-1 (2.5 FU)
—
Y4"
BATH-1 (3 FU)
Y"
X"
SH-1 (2 FU)
X
X"
SK-1 (1.25 FU)
Y4
Y4"
W13-1 (3 FU)
Y"
X"
NOTE: SIZING APPLIES TO ALL UNIT
PLANS.
UNIT X3
ENLARGED UNIT PLAN
SCALE: 1 /4" = 1'-0"
UNIT X2
ENLARGED UNIT PLAN
SCALE: 1 /4" = 1'-0"
3'
P300
0
UNIT 10
ENLARGED UNIT PLAN
SCALE: 1 /4" = 1'-0"
UNIT X1
ENLARGED UNIT PLAN
SCALE: 1 /4" = 1'-0"
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
rrn
EMERALD CITY
ENGINEERS, INC
21 705 Highway 99
Lynnwood, WA 98036
TEL:425-741-1200 it
PROJECT TITLE / PROJECT ADDRESS
1
New Construction
P300 f o r
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
p�� : ° ° of ASy •°°•. C
a
\
00000��<
io" 0-21
SHEET TITLE
ENLARGED
UNIT
P300 PLANS
SHEET NUMBER
P300
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOULET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P300.DWG 11-08-2021 12:28
ROOF
r If r If
N I _ � I � N ILLI�
I N Imo, hotI �I(D 10) rI�
1 hot I
I 1 I i I —1 „
» I F — — I I 1Y219 I I
ROOF
1�
SK I i
LEVEL 3 HB I I
I BA I WC I
I LEVEL 3
I�
_ I�
LL-
N I�
� I LL
r I�
I
I�
I N
- I�
LL-N
LL �I�
rIN
I �
Nn
� „ I N
1 I
N 1 hot I A
I NN
LL-� I �
I
�
1r2
N
L` 1 hot I
F
I CW I
I SK I
I I
I
I
I
2" I
F—
I LV
hot
_
LEVEL 2
HB
I
I
I
I
� �
I BA I
I I
I WC
I
I LEVEL 2
T = r I
NIA
N I�
IN
_ I�
I N
N IA
NIA
IN
1 I 1� „ I I IN
h I N
I�
D I N
L� 11hJ
IIN
1 J N
D I ;�'l
L�
NILL
In
J
N
J J I 1 I
LL I I I �--
1 I
I
r
I
„I
1J
I
„
2
1 h„
I LV
1h„ I
J
`o J 1�2' --2„ J I LV
I SK
J
i--
I
LEVEL 1 I HB
I HB I BA I WC
I BA
I WC
LEVEL 1
N�
� �
N�
N�
n
N N
L�
1
� N �
_
N
1
�
NL�
1
N
N
� In
N�
�
�
�
N
17
N
In
N
(1D
FLAG NOTES:
REFER TO DETAIL 3 ON P4.04
FOR RISERS RECEIVING WASTE
FROM SUDS PRODUCING FIXTURES
3 STORIES OR LESS.
WASTE &VENT RISER DIAGRAMS
SCALE: NONE
CD CD
O O O
BA = BATHTUB OR SHOWER (2 FU)
LV = LAVATORY (1 FU)
WC = WATER CLOSET (3 FU)
SK = SINK WITH DISHWASHER (2 FU)
CW = CLOTHES WASHER (6 FU)
CD
NOTE:
PROVIDE TEST TEES AT EACH
FLOOR FOR WASTE AND VENT
STACKS FOR TESTING THE
PLUMBING SYSTEM.
CD O
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
rrn
"LMjj
EMERALD CITY
ENGINEERS, INC
21 705 Highway 99
2Lynnwood, WA 98036
00TEL:425-741
PROJECT TITLE / PROJECT ADDRESS
New Construction
for
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
p�� : ° ° of ASy •°°•. C
a
• \
00000��<
10-20-21
SHEET TITLE
WASTE & VENT
RISER DIAGRAMS
SHEET NUMBER
P400
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOULET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P400 WASTE AND VENT RISER DIAGRAMS.DWG 11-08-2021 12:28
ROOF
LEVEL 3
LEVEL 2
LEVEL 1
WATER SUPPLY RISER DIAGRAMS
SCALE: NONE
11/9"(13.0 FU
L�
Ln
O
N ,
11/9"(13 FU
O O O
CW = CLOTHES WASHER (4 FU) REFER TO ENLARGED PLANS
BA = BATHTUB (4 FU) FOR EXTENSION OF PIPING INSIDE
LV = LAVATORY (1 FU) RESIDENTIAL UNITS.
WC = WATER CLOSET (2.5 FU)
SK = KITCHEN SINK & DISHWASHER (1.5 FU)
NOTE: PROVIDE SUFFICIENT CONNECTIONS (SWING JOINTS, ETC.) TO
PROTECT THE PIPING FROM STRAIN AND STRESS DUE TO MULTISTORY
BUILDING EXPANSION AND CONTRACTION.
ROOF
LEVEL 3
LEVEL 2
LEVEL 1
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
rrn
EMERALD CITY
ENGINEERS, INC
21 705 Highway 99
2Lynnwood, WA 98036
00TEL:425-741
PROJECT TITLE / PROJECT ADDRESS
New Construction
for
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
p�� ; ° ` of ASy •°°•. C
a � '
'pFG/ R
\
4�000000�°<
10-20-21
SHEET TITLE
WATER SUPPLY
RISER DIAGRAMS
SHEET NUMBER
P401
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOULET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P401 WATER SUPPLY RISER DIAGRAMS.DWG 11-08-2021 12:28
Haynes
CONNECT ABOVE 1/2"
a n,
CENTERLINE OF
MAY EXTEND AS
MAIN
WASTE OR VENT
V/*11son
W11sc
BALL VALVE
WALL
PIPE INSULATION PIPE
MOUNT PRIMER VALVE
INSULATION JACKET U.L. LISTED &APPROVED
Lund
PIPE CLAMP
12" FOR EVERY 20'
CHROME WALL COVER
FIRE SEALANT
OF TRAP PRIMER LINE
AND SCREW AT FINISH
AREAS ONLY
_ FLOOR
PRECISION PLUMBING
PLUGGED TEE
o o +
PRODUCTS,INC PR-500
WITH CLEANOUT
x
TRAP PRIMER VALVE
RECEIVED
1/2" GRAVITY TRAP
FLOOR
N18 2021
ov
FLOOR DRAIN PRIMER LINE
M
--
CITY OF EDMONDS
DEVELOPMENT SERVICES
CAULKING PIPE SLEEVE-1 "(MIN.)
DEPARTMENT
1
LARGER THAN
rI
PENETRATING PIPE
SLOPE TRAP
INTERIOR WALL CLEANOUT WCO
CONSULTANT NAME CONSULTANT LOGO
/
PRIMER LINE
ELEVATION
P-TRAP
rrn
TRAP PRIMER
CLEANOUT TO BE CAST
3/4" NEOPRENE
PIPE INSULATION WAFFLE PAD,
PIPE SLEEVE MASON MINI W
IN COVER
INSULATION JACKET
DETAIL `J
PVC OR ABS CLEANOUT
6" THICK BY 18"
PIPE CLAMP t.
`"'a^''°'
''' '
EMERALD CITY
SCALE: NONE P402
WITH COVER FOR
SQUARE CONCRETE APPLICABLE DUTY
"'' = DETAIL'A'
��''^`���
ENGINEERS, INC
PAD
21 705 Highway 99
Lynnwood, WA98036
GRADE OR PAVING FINISHED
FLOOR
•:•.-°.`'f'
`ci.;"- v'v.:+•'>:
425- TEL: 741-1200
- -
FIRE PROOFING SEAL
PROJECT TITLE /PROJECT ADDRESS
-
PLAN CUT JACKET & INSULATION TO ALLOW
1
FOR PIPE CLAMP ARM EXTENSION
-III -III -III -III
PVC OR ABS EXTENSION-
�SAME AS DRAIN SIZE
& FILL-IN VOID W/ INSULATING CEMENT
New Construction
PVC OR ABS LONG SWEEP UP TO 4" DIAMETER
%4 BEND OR PVC OR ABS
COMB. Y & %$ BEND.
f o r
(USE REDUCING TYPE
PIPE RISER SUPPORT
FOR SIZE CHANGES)
DETAIL
EDMONDS
SCALE: NONE P402
BUILDING WASTE DIRECTION OF FLOW
CROSSING
OR DRAIN
EXTERIOR CLEANOUT TO GRADE (COTG) INTERIOR FLOOR CLEANOUT (FCO)
APARTMENTS
INSTALL CW ROUGH -IN APPROXIMATELY 8" AFF
(CONFIRM ELEVATION WITH ARCH PLANS).
CLEANOUT DETAIL r
WATER CLOSET CW SUPPLY
23830 Edmonds Way
SCALE: NONE P402
DETAIL 6
TERMINATE SLEEVE FLUSH WITH %PIPE SLEEVE OF SIZE TO
FINISHED WALL SURFACE PASS PIPE AND INSULATION
Edmonds, WA. 98026
(IF APPLICABLE) WITH MIN %"
SCALE: NONE P402
ANNULAR SPACE
REVISIONS
PIPE AND INSULATION
(IF APPLICABLE)
CENTERED IN SLEEVE FINISHED ESCUTCHEON PLATE
FLUSH AGAINST WALL AND
FIRESTOP SLEEVE AT OF SIZE TO COMPLETELY
FIRE -RATED WALLS COVER OPENING
CONCEALED PIPING PIPING EXPOSED TO VIEW
1 /3 H FROM TOP
SHUTOFF
OF THE TANK
INTERIOR WALLS
VALVE
TRAP PRIMER
PERMIT DOCUMENTS 29 JULY 2019
UNISTRUT P-1000T
BID DOCUMENTS
0 o CHANNEL, BOLT TO
0 WALL STRUCTURE
SEALING AND ANCHORING
CONSTRUCTION DOCUMENTS
FIRE SPRINKLER
WITH (2) 3/8" BOLTS,
GALV STEEL PIPE SLEEVE COLLAR FOR CONCRETE
VENT TO RISER DISCHARGE
MINIMUM.
OF SIZE TO PASS PIPE WALLS
EXTERIOR
AND INSULATION WITH
IN Y/2" ANNULAR SPACE SEAL ENDS OF SLEEVE WITH
PROJECT NUMBER
0 o
EXPANDING FOAM WEATHER—
TIGHT SEALANT
DRAWN BY CIS
1 h" VENT PIPE
CHECKED BY MB
z
P1458 BRACKET, (3) 1 /2"
INSULATE AS APPLICABLE, PIPE AND INSULATION
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
3" COLLECTOR
FUNNEL
BOLTS AND NUTS, TYPICAL
: :::
EXTEND OUTDOOR JACKETING IF APPLICABLE
THROUGH PENETRATION AND ( )
OF 2 PLACES.
CENTERED IN SLEEVE
TERMINATE NEATLY 3" FROM
2"x16GA. GALV.
INSIDE FACE OF WALL
COAT EXTERIOR SURFACES
Ooao❑0000
oOo�\�J D. e�OpO
O,` ....•'W•" O O
S.M. STRAP
OUTDOOR INDOOR OF SLEEVE WITH COAL TAR
O ofN . O
p :° .O
NOTE: THE SEISMIC STRAPS
a �' ❑
SHALL BE AT POINTS WITHIN
❑
4%3" REDUCER
THE UPPER 1 /3 AND LOWER NOTE:
1/3 OF THE WATER HEATER. SEISMIC STRAPS NOT REQUIRED
EXTERIOR WALLS ABOVE GRADE
2" WASTE PIPE P-TRAP
AT THE LOWERPOINT A IF APPROVED BY AHJ.
OOp'��ONAL E'p00
oo❑❑❑oo
MINIMUM OF 4, SHALL BE
FLOOR
MAINTAINED ABOVE THE
CONTROLS WITH THE STRAP.
I0^20-21
SHEET TITLE
Li
DETAILS &
DIAGRAMS
WATER HEATER HUB DRAIN
WATER HEATER SEISMIC STRAPPING
PIPE SLEEVES THROUGH WALLS
DETAIL
DETAIL rT
DETAIL 2
SHEET NUMBER
SCALE: NONE P402
SCALE: NONE P402
SCALE: NONE P402
P402
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOULET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P402 DETAILS AND DIAGRAMS.DWG 11-08-2021 12:27
CONCRETE FLOOR
OR WALL
THROUGH -SLAB
PENETRTION
SLEEVE OR WRAP
PIPING TO PROTECT
AGAINST BREAKAGE
PER CODE
PIPE SLAB PENETRATION
DETAIL 5
SCALE: NONE P403
PEX BRANCH LINES TO EACH FIXTURE
UNIT MANIFOLDS WITHOUT SPLICES.
(TYP)
TTTT
CW SUPPLY
MANIFOLD LOCATED MIN 18" L I J_ _L JL
FROM WATER HEATER CONNECTION.
fT&P M
8>> I K " �
T SUBMETER
EXPANSION TANK
FAUCET
SINK
COUNTER TOP
TO SANITARY
SEWER
APPROVED DISHWASHER'S
AIR GAP FITTING
HOSE CLAMP (TYP)
HOSE
DISHWASHER
FAUCET DRAIN HOSE
FOOD WASTE
DISPOSER
FLOOR
DISHWASHER DRAIN CONNECTION
DETAIL
SCALE: NONE
OUTDOOR JACKETING
TO ELBOW
ROOF CURB
ASSEMBLY -
45'
FROM
DISHWASHER
18 GA GALV STEEL
HOOD WITH WATER-
TIGHT JOINTS. USE
SS FASTENERS
FILL VOID WITH
URETHANE FOAM
/ INSULATION (TYP)
SUPPORT LIP
SECURE TO CURB,
Y2" SS LAG BOLTS,
MIN 2 PER SIDE,
SILICONE SEALANT
IN HOLE PRIOR TO
INSERTING BOLT
(TYP)
SEISMIC STRAPS WATER ROOFING
(SECURE TO STRUCTURE) HEATER
4 ROOF DECK
P402 WATER HEATER DRAIN PAN,
26" OATEY 34164 OR EQUAL FLASHING COLLAR AND
SEALANT, FASTEN TO
DECK
WATER RTAD
HOLDRITEEAT40ESS24NA PIPE PENETRATION THROUGH ROOF
DETAIL
HUB DRAIN
RESIDENTIAL WATER HEATER
DETAIL
SCALE: NONE
WASTE LINE TO
SANITARY SEWER
VENT
TRAP PRIMER
6
P403
SCALE: NONE
NOTES
ACW=AUTO CLOTHESWASHER
CLOTHESWASHERS ARE USED IN THESE
DRAWINGS TO ILLUSTRATE AN EXAMPLE
OF A SUDS PRODUCING FIXTURE. SECTION
711.0 REQUIRES THAT BATHTUBS, LAUNDRIES,
WASHING MACHINE STANDPIPES, KITCHEN
SINKS AND DISHWASHERS BE CONSIDERED
AS SUDS -PRODUCING FIXTURES.
SECTION 711.0 STATES..."DRAINAGE CON-
NECTIONS SHALL NOT BE MADE INTO A DRAIN-
AGE PIPING SYSTEM WITHIN EIGHT (8) FEET
(2438 mm) OF ANY VERTICAL TO HORIZONTAL
CHANGE OF DIRECTION OF A STACK CONTAINING
SUDS -PRODUCING FIXTURES." PREVIOUS CODE
WORDING USED THE PHRASE "FIXTURE CON-
NECTIONS" WHICH WAS DIFFICULT TO INTERPRET
SINCE IT WAS NOT DEFINED IN CHAPTER 2. A
"DRAINAGE CONNECTION" BY DICTIONARY DE-
FINITION IS SIMPLY ANY FITTING CONVEYING
LIQUID WASTE OR SOIL INTO A DRAINAGE PIPING
SYSTEM. SECTION 711 WOULD NOT PREVENT
THE INSTALLATION OF A "VENTING CONNECTION"
(OTHER THAN A REQUIRED PARALLEL VENT STACK)
INSTALLED TO RELIEVE AIR PRESSURES IN THE
SYSTEM WITHIN EIGHT FEET OF THE VERTICAL TO
HORIZONTAL CHANGE IN DIRECTION.
SUDS RELIEF - 3 STORIES OR LESS
DIAGRAM
SCALE: NONE
10'
10'
5'
2'
INSULATION
PIPING
OPENING IN DECK
TO MATCH CURB ID
F
F
VTR
I
ACW
I
ACW
_J
ACW
RECEIVED
Nov 18 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CONSULTANT NAME / CONSULTANT LOGO
rrn
EMERALD CITY
ENGINEERS, INC
21 705 Highway 99
Lynnwood, WA 98036
TEL:425-741-1200 it
PROJECT TITLE / PROJECT ADDRESS
New Construction
for
EDMONDS
CROSSING
APARTMENTS
23830 Edmonds Way
Edmonds, WA. 98026
REVISIONS
PERMIT DOCUMENTS 29 JULY 2019
BID DOCUMENTS
CONSTRUCTION DOCUMENTS
PROJECT NUMBER
DRAWN BY CIS
CHECKED BY MB
DATE 29 JULY 2019
ARCHITECT/ ENGINEER SEAL
000a❑❑❑0000
o° N p' e� °o
op��%. of WASy °°°°•.. � p
.............
° \O�
O�-4�000000��0
10-20_21
SHEET TITLE
DETAILS &
DIAGRAMS
3 SHEET NUMBER
P403
P403
© 2016 Haynes Wilson Lund Architects, Ilc
COPYRIGHT 2021, EMERALD CITY ENGINEERS, INC.
CGOULET J:\2392-001 EDMONDS CROSSING, EDMOND, WA\DWG\P403 DETAILS AND DIAGRAMS.DWG 11-08-2021 12:27