REVIEWED RESUB1 BLD2022-1034+Structural_Analysis_or_Calculations+9.6.2022_10.20.31_AM+3090963i nfop b2enginears-corn 425-318-7047 (0) 425-318-0031 (G) REVIEWED BY CITY OF EDMONDS RESUB Sep 06 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-1032 MONDS KITCHEN MECHANICAL SUPPORT 320 5TH AVE.S.,EDMONDS WA,98020 STRUCTURAL CALCULATIONS PROJECT NO: 22230 DATE: 08/08/2022 PREPARED BY: KREED ASKIN Page 1 of 5 5\),\ Bq P of wasy� S,A o z A.Sj 'PL 43789 C"URALENS\G\ ASS/ONAL EN RESPONSE TO COMMENTS DATED AUGUST 8T", 2022, BY PLAN REVIEWER ERIC CARTER. PLEASE CONSIDER STRUCTURAL CORRECTIONS, AND CORRESPONDING RESPONSES BELOW. 1. The combined weight of the hoods make up air units and associated equipment appears to exceed 400#'s. In accordance with ASCE 7-10, a structural evaluation of the roof /ceiling structural is required please provide documentation from a Washington state licensed engineer of the adequacy of the assembly. RESPONSE: The weight of the mechanical unit are 235 lbs each, which do not exceed 400 lbs is need to be checked for seismic design according ASCE 7-10 section 13. Please refer to the attached sheet S1 drawing shows assembly of kitchen hood with lateral bracing by using Unistrut. Please see attached pages for design criteria and calculation for gravity and seismic loadings This concludes our responses to the above comments. Thank you, Kreed Askin Page 2 of 5 info@b2engineers.com 425-318-7047 (0) 425-318-0031 (C) EDMONDS KITCHEN MECHANICAL SUPPORT 320 5TH AVE.S.,EDMONDS WA,98020 STRUCTURAL CALCULATIONS PROJECT NO: 22230 DATE:25/08/22 PREPARED BY: BASRI BASRI PE, SE Design Criteria International Building Code (IBC) 2018 American Society of Civil Engineers (ASCE) 7-16 Kitchens Remodel Involving the addition of Kitchen hood which supported by new beam .the hanging portion consisting of unistrut assembly to support the adequate of lateral force. Please see attached calculations for your reference Seismic Criteria SS, %g 128.5 S1, %g 45 Risk Category III Site Class D Ductility Factor, R 6 Seismic Performance Category D Page 3 of 5 WIND SEISMIC PER ASCE 7-16 m�Job No. 22230 Sheet No. 2 • www.b2engineers.com Edmonds kitchen mechanical 7516 NE 153rd Place NE Project Name support Sheet Title seismic design Kenmore, WA98028 Checked By Basri Made By Basri (425) 296.2993 Date Date COMPONENT SEISMIC FORCE PER ASCE 7-16 General input 128.5 128.5 Site Class D Roof elevation (h) (ft) 12.5 Risk Category II Component input Elevation of component attachment (z) (ft) 7.6 Weight of component (Ibs) 235 3.HVAC units, fans & switch Component type gear Component seismic calculations Fa 1.0 SDs 0.86 aP 2.5 RP 6 FP (Ibs) 74.4 FP,m- (Ibs) 322.1 FP.min (Ibs) 60.4 QE (Ibs) 74.4 Qv (Ibs) 40.3 Page 1 of 1 Project: edmond project Location: Beam at kitchen Hood (Bh) Multi -Loaded Multi -Span Beam [2015 International Building Code(2015 NDS)] 3.5 IN x 5.5 IN x 10.08 FT #2 - Douglas -Fir -Larch - Dry Use Section Adequate By: 175.8% Controlling Factor: Moment DEFLECTIONS Center Live Load 0.00 IN L/- Dead Load 0.13 in Total Load 0.13 IN L/931 Live Load Deflection Criteria: L/240 Total Load Deflection Criteria: L/180 REACTIONS A B Live Load 0 lb 0 lb Dead Load 234 lb 192 lb Total Load 234 lb 192 lb Bearing Length 0.11 in 0.09 in Span Length 10.08 ft Unbraced Length -Top 0 ft Unbraced Length -Bottom 10.08 ft Live Load Duration Factor 1.15 Notch Depth 0.00 MATERIAL PROPERTIES #2 - Douglas -Fir -Larch Base Values Adjusted Bending Stress: Fb = 900 psi Fb' = 1053 psi Cd=0.90 CF=1.30 Shear Stress: Fv = 180 psi Fv' = 162 psi Cd=0.90 Modulus of Elasticity: E = 1600 ksi E' = 1600 ksi Comp. -L to Grain: Fc -1= 625 psi Fc -1' = 625 psi Controlling Moment: 561 ft-lb 6.15 Ft from left support of span 2 (Center Span) Created by dead loads only on all span(s). Controlling Shear: 232 lb At a distance d from left support of span 2 (Center Span) Created by dead loads only on all span(s). Comparisons with required sections: Read Provided Section Modulus: 6.4 in3 17.65 in3 Area (Shear): 2.15 in2 19.25 in2 Moment of Inertia (deflection): 9.38 in4 48.53 in4 Moment: 561 ft-lb 1548 ft-lb Shear: 232lb 2079lb Dennis StruCalc 9.0 StruCalc Version 10.2.1.0 8/29/2022 11:44:19 AM Page 5 of 5 page o� LOADING DIAGRAM 1 3 2 4 10.08 ft (FORM LOADS Center Uniform Live Load 0 plf Uniform Dead Load 0 plf Beam Self Weight 4 plf Total Uniform Load 4 Of POINT LOADS - CENTER SPAN Load Number One Two Three Four Live Load 0 lb 0 lb 0 lb 0 lb Dead Load 133.4 lb 58.8 lb 133.4 lb 58.8 lb Location 1.23 ft 3.73 ft 6.23 ft 8.73 ft