APPROVED BLD PLN - BLD2020-1343+Architectural AND Site_Plan+1.12.2021_7.41.09_AM+1984808City Of Edmonds Building Department Work ADDITION AND DECK Address 7824 175TH ST SW Owner HAMBY ----------------------------------- Approved Dater 1-19-2021 Building Official IEri & Cia rfe r Permit Number BLD2020-1343 APPROVED BY PLANNING az �o Jan 12 2021 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE V \-- PLINTH/FRAMING ABOVE 12 4 (MAX) 18„ (2) #4 EACH WAY ` TOP & BTM APPROVED \\0 0A1 TIE -BEAM J ` ` ` 16" PLANS MUST BE TB ° TIE-BEAM ON JOB SITE I IKF-- COVER CONCRETE TIE BEAM w/ (2)-#4 CONTINUOUS LAP SPLICES 16" EXTEND INTO ADJACENT NEW CONTRUCTION FOOTINGS w/ STANDARD HOOKS EXTEND BARS 4" INTO EXISTING FOOTINGS, SEE DETAIL TBE TB TIE BEAM N.T.S. TBXA NOTES: -Simpson AT-XP epoxy ❑■ -Threaded rod, 0 per plan (A307) -Hole diameter; threaded rod diameter + %6' ti -16" embed into the concrete, u,n.o. -Follow the manufacturers' specifications for 0 installing the anchor and hardware http://www.strongtie.com/products/anchorsystems/adhesives/adhesive_ anchoring_install.html# seconds imin.) 80 14 cycles (min.) ds seconds (min.) 80 psi min. psi min. EPX EPDXY -ANCHOR BOLT LJ N.T.S. EXPA ALL PILES 3" 0 SCH 40 STEEL PIPE REFER TO THE STRUCTURAL NOTES AND GEOTECHNICAL REPORT FOR OTHER RELATED INFORMATION VERTICALLY OINSTALLED PIPE PILE PILE LOCATION N.T.S. 01 18 X 18 X 16" FOOTING 0 FTGPJ FOOTING WITH PIN -PILES N.T.S. FOOTING TO TIE -BEAM N.T.S. EPX 12" MIN (VIF) ` EXISTING STEMWALL ABOVE PI ON VTFW nn - rAn TIE -BEAM #4 BARS CONTINUOUS FROM TIE - BEAM w/ 4" EMBED INTO EXISTING FOOTING (2) #4 EXISTING FOOTING (VIF) TIE -BEAM TIE BEAM TO EXISTING FOUNDATION N.T.S. =TE 4 6" ES 6" 4" EMBEDMENT EPX 12 4 (MAX) � BEARING SOIL CFrTTnN VFTW FRAMING ABOVE EXISTING STEMWALL EXISTING FOOTING (VIF) RE Jan 12 SSS Number: s2009O29 Project Name: 7824 175th St SW Owner: Michel Design Project Location: 7824 175th St SW, Edmonds, WA Design Professional: Michel Design M ice) Ln N O O 0 H Q LU �\ Ln N J � � Z E O V � Lori U) G_ z U) � Lin E O U 0) Q) U) V) U) O c �14 U1 A WAS . L ` 55305 01 ALI This space reserved for governing jurisdiction stamps ORIGIN DATE: 10/28/2020 REVISED: ---- S2.4 U 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 PIN PILE — BEAM 2X6 WALL 2X4 WALL BEARING 0 2X4 WALL PLEASE 5 5HEET5 FOR ALL 5TRUCTURE DETAIL5 EXI5TING DECK TO BE REPLACED 8068 5GLD TO REPLACED PLEASE 5 5HEET5 FOR ALL 5TRUCTURE DETAILS 10' ff 12' �9 4040 H5 EDGE OF DECK ABOVE 25'10" 2'4-1/2" --OLD DECK EDGE OF DECK ABOVE ---- —— — — — — — — - \ 1214" 41 4" 416" 09-1/2" \ \ o \, PLEASE 5 5HEET5 FOR ALL 5TRUCTURE DETAIL5 2'4-1/2" FAMILY ROOM WORK HERE UNDER PERMIT # BLD2020-0649 • w w w A w w w A w w A w Al LU A AA A W O O 5ED1200M LL ^^ 0CFM Az�� n" 5, TO 1j2 N „�ww Q o O " " 7'10 n O AAAA A w A A A A A A n CLOSET A 471.11 fib w Demo Closet w n n n A A h h h h h h n h h n h " ^ h " n h h A h h A h A A h A A h A A h A A h h h n A A .. .. A h h A h A A A .. A A A A A A A A .. .. .. .. .. .. A w w w A n .. .. .. .. .. .. .. .. .. .. .. .. .. .. w 4' w w A A • w 32'9-1/2" " A UTILITY ROOM " A A • w A A A h" GARAGE •• A •• A •• " 105 5q ft A " 19'4" :� a .... . EXI5TING BEDROOM 10'7-1/2" ADD 2'6"X2'6"X8" PIER FOR TRU55 BEARING ABOVE3110, O um 4'6-1/2" 4'6-1/2" 4'7" 1/4"=1'-0. on i 5'(0-" z H U) W Nx W �3 m N 1� C7 0 E z W3 Q � V 0 t� N I^� V / O 00 z O LO H rl 0 z U cv 0 Q 002 0 L1J Z LL W � O — OLL Q C) i Q LU Q Ci�: Q C) OLUp Ozz ce LU Q Q LUz m LU � Q RESUB Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVISIONS: PRINTED: I 12/05/20 5' x p PIN PILE — BEAM 2X6 WALL - R21 IN51-11L MEEK== 2X4 WALL BEADING 0 2X4 WALL 0 120V SMK DET W/BATT BACKUP 15'4-1/2" EXISTING DECK TO BE REPLACED HWT 4/12 5HED ROOF WITH COMP ROOFING EXTERIOR TO MATCH HOUSE 3068 INSULATED 4' 5LA13 I UNCONDITIONED ON PEKIM I I SHED THICKEND EDGE I I 4' 1 1 LD <D NEW DECK WITH ELA5TIMERIC COATING PLEASE S SHEETS FOR ALL STRUCTURE DETAILS 0 N GARAGE 12' cs� r O m 0 4040 H 5 4040 P I 32'9-1/2" A:A 1/4" = 1' - 0" 37'5-1/2" FAMILY DOOM NOTE: WORK IN TH15 AREA ONLY KITCHEN 5283.74 ft z DOWN 19'1/2" (o EX15TING PORCH 25'10" OLD DECK 615.95 ft 2 NEW DECK AREA NEW DECK WITH ELA5TII I PLEASE S SHEETS FOR ALL I STRUCTURE DETAILS r- 0 a A A A A A A A A w w w w A A A A EXISTING DECK over living Space A w A A A A A A A 210.63 ft 2 A A A A A A A A w A A w w w w w A w w w A A A A A A A A NEW LIVING AREA COA NG o o m II o 4'7" 4050 NOTE: 20 5Q FT NET GLAZING L055 31-1/2" 3'6" 211" N � a TBR 8 685GD TB 4X4 COULMN BELOW " HIGH WALL KITCHEN SIND FAUCET SHALL BE RATED AT 1.75 GPM OR LESS TO MEET WSEC R406 .5 CREDIT EXISTING BEDROOM EXISTING 3068 o NEW DOWN EX15TING BATH AA NEW PORCH 5/4X6 DECKING SLOTTED NOTE: WORK IN THIS AREA ONLY N d- RESUB Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z H u W Nx rn 3 W� z � 3 ; Q 3 U a Q . 0 P� fV V00 O V z O LO � w (ri I --I rl 0 z UNO Q 00 2 0 Lu m � o Q � LL 2 C) �z Q V w Z Q p Q i�: C) Z Z oa m Q w � REVISIONSI PRINTED: 12/05/20 MAX HT 122.22' VENTILATION — ROOF ACTUAL HT120' - 7' ATTIC VENTILATION REQ'D 1 S.F./300 S.F. � z EAVES 4.7 SQ IN/LF (BIRD BLOCK W/ (3) 2 HOLE) _ ROOF JACK 51 S.I. /EACH PROVIDE 2 JACKS (v'� 0-0 OR RIDGE VENT @ 24 S.I. / LINEAL FOOT PROVIDE 10' r ^ N m N C� zW 4) 1-4 E -. V a � o . . . . . . . . . . ... N N NEW ADDITION Q0 I ('V 0 ALUM RAILING 00 WITH GLA55 5Y5TEM TY12 5LOFE 1/4" FER FOOT - - - - - O Ln cry -Fp .......................rl AVE GRADE 97.22' z UNO 0002 � � 0 Lu 5A5E ENT FLOOR 5'6" EXI5TING FOUNDATION EX15TI N G FOUNDATION z m 61111171511 O EXISTING O Q NEW PIER ON PIN PILE ' TIE RETAING LL WALL TO REMAIN 0 �z Q uz Q 0 Q 2 � 0 O Lu 0 Ozz PLEASE 5 SHEETS FOR ALL ce 0 Q STRUCTURE DETAIL5 0 z W m Q G REVISIONS: PRINTED: 12/05/20 NORTH ELEY ION RESUB Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z 0.0 0.� m N (� O � � 3 � A u A � 0 ADDITION Qo N L O 00 m Li � � 0 Z LEOFPETK�AOOVE UN0 O 00 Q W R38 UNDER NEW FLOOR m z � � LD OQ U— = PLEASE 5 5HEET5 FOR ALL 5TRUCTURE DETAIL5 0 � Q 0 U z Q uj Q PLEA5E 5 5HEET5 FOR ALL 5TRUCTURE DETAIL5 — 0 O w p OzZ WE5T VELEATION0 ce Q Q w Q C_ G REVISIONS: PRINTED: 12/05/20 Im RESUB Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT NOTES • RECESSED LIGHTING TO BE IC RATED -MIN. HEADROOM CLEARANCE OF T-6" IS REQ'D IN ALL HABITAL SPACES, & T-0" IS REQ'D ELSEWHERE -PROVIDE ONE OPENABLE ESCAPE WINDOW IN BASEMENT & IN EACH SLEEPING ROOM MEETING ALL THE FOLLOWING REQUIREMENTS: 1. AN OPENABLE AREA OF NOT LESS THEN 5.7 SQ.FT. 2. A MIN. CLEAR HEIGHT OF 24" 3. A MIN. CLEAR WIDTH OF 20" 4. FINISHED SILL HEIGHT OF NOT MORE THAN 44" ABOVE THE FINISH FLOOR. 5. ALL WINDOWS TO INCLUDE FRESH AIR VENTS OR METERED FRESH AIR SUPPLY @ FURNACE 6. ALL WINDOWS & DOORS HAVING ACCESS TO EXTERIOR OR UNHEATED TO BE SEALED PER SEC. 502.4.3 (WAC) FIREPLACE NOTES l *INSTALLATION, USE, & MAINTENCE PER MANUFACTURE'S SPECS & APPLICABLE STATE CODES: GAS FIREPLACE: HEAT&GLO SL-750TR-D R.O. 42" X 38-1/4"X16-1/4" STAIR NOTES -MAINTAIN REQ'D NO-HR STAIRS ENCLOUSURES & MIN 6'-8" HEADROOM @ STAIRS -STAIR BACKING FOR HAND RAIL *STAIR: RISE = 7.71" RUN = 10" GARAGE NOTES (1HR CONSTRUCTION) •5/8" GYP TYPE "X" SHEETROCK REQ'D TO SEPARATE GARAGE FROM DWELLING•GAS VENTING IN UNCONDITIONED SPACE TO BE TYPE B OF L VENT MATERIAL • SOURCE OF IGNITION OF GAS APPLIANCES MUST BE RAISED A MIN. OF 18" ABOVE FINISHED FLOOR IN GARAGE IMC •26 GAUGE OR THICKER SHEET METAL FOR AIR DUCT WITHIN THE GARAGE AND WHICH PASSES THROUGH THE ADDITIONAL PLUMBING REQUIREMENTS: -MAIN BUILDING SHUT-OFF REQ'D ON WATER SUPPLY LINE. *PRESSURE REDUCTION VALVE ON MAIN WATER SUPPLY LINE REQ'D BY CITY CODE •EXPANSION TANK REQ'D ON EA. HOT WATER TANK. *VENT HOT WATER TANK RELIEF VALVE DIRECTLY TO THE OUTSIDE *HOT WATER HEATER MUST BE SEISMICALLY ANCHORED OR STRAPPED @ POINTS WITHIN THE UPPER 1/3 & LOWER 1/3 OF ITS VERTICAL DIMENSION. @ THE LOWER POINT, A MIN. DISTANCE OF 4" MUST BE MAINTAINED ABOVE THE CONTROLS W/ THE STRAPPING •1" AIRGAP REQ'D ON DISHWAHSHER •ALL SHOWERS HEADS TO BE EQUIPPED W/ FLOW CONTROL DEVICE TO LIMIT FLOW TO 3 GPM -HOSE BIBS (EXT. FAUCETS) ARE REQ'D TO HAVE A PERMANENTLY AFFIXED ANTI -SIPHON DEVICE INSTALLED • SOAKER & JETTED TUBS SHALL BE INSTALLED & SUPPORTED PER THE MANUFACTURER'S INSTALLATION SPECIFICATIONS GARAGE WALL. IBC. IRC R314 SMOKE DETECTORS REQUIRED THE ISSUANCE OF THIS PERMIT REQUIRES INNERCONNECTED SMOKE DETECTORS WITH BATTERY BACKUP IN THE FOLLOWING LOCATIONS: *IN EACH SLEEPING ROOM *OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS *ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY ELOW THE UPPER LEVEL. INSTALLER SHALL PROVIDE THE MANUFACTURER'S INSTALLATION, OPERATING INSTRUCTIONS, & A WHOLE HOUSE VENTILATION SYSTEM OPERATION DESCRIPTION. A LABEL SHALL BE AFFIXED TO THE WHOLE HOUSE TIMER CONTROL THAT READS "WHOLE HOUSE VENTILATION" (SEE OPERATING INSTRUCTIONS). ALL STAIRWALLS BLOCKED VERT. & HORIZ. @ 10' O.C. ►. U z ll GENERAIL NOTES: 1) OWNER: MIKE AND DIANA HAMBY PROJECT CONTACT: ROB MICHEL 206-930-2445 2) LEGAL: TAX ACCOUNT NUM13EK: 00679200000200 3) DESIGN LOADS: FLOOR, L: 40 PSF, WIND: (3 SEC GUST) 110 MPH, ESPOSURE B, GOUND: ROUGH, SNOW LOAD: 25 PSF, LATERAL: 0.130 TRANS AND 0.130 LONG, SEISMIC: 16327 LBS 4) FROM TABLE R301.2(1): GROUND SNOW LOAD: 25 PSF, WIND SPEED: 85 MPH, SEIMIC: D2, WEATHERING: MODERATE, FROST: 18", TERMITE: SLIGHT TO MODERATE, DECAY: SLIGHT TO MODERATE, WATER TEMP: 27 DEGRESS F, NO ICE SHIELD, FLOOD HAZ: FIRM MAPS 11-8-99, AIRE FREEZE INDEX: 0-1,000 5) SOIL CLASSIFICATION: ALDERWOOD LOAM, SANDY SILTY LOAM, CONCRETE STRENGTH: 2,500, #3&#4 BARS TO BE GRADE 40 AND #5 GRADE 60. 6) SEE SHEET S2 FOR LUMBER AND PLYWOOD INFORMATION. 7) SEE SHETT S1 FOR NAILING SCHEDULES. 8) GAS HOT WATER HEAT 2015 INTERNATIONAL BUIDING CODES *REFER TO S PAGES FOR ALL STRUCTURAL DETAILS NOTE: HANDRAIL MUST- - BE 34" TO 38" MAX. - RESIST 200# LOAD PER IBC - 1 1/4" - 2" DIA. CONT. W/ 1 1/2" CLR. FROM WALL 4 THRUST BLOCK (3) - 2X12 STRING EA. SIDE & O.C. TKEAD � REFER F L R, N _ LLI w EXTEND HANDRAIL: (BEYOND TREAD NOISING) - 6" PRIVATE - 12" PUBLIC TOP - 12 PUBLIC BOTTOM - AND RETURN OR CONT. (2) - 2X HEADER W/ LEDGER OR JST. HGRS. FOR CARRIAGE SUPPORT 1 1/4" -2" DIA. STAIR NOSING TO BE ROUNDED & SLIP RESTANT 5 / 8" TYPE 'X' GYP. BD. @ AREAS ACCESSIBLE UNDER STAIRS 2X4 FIREBLOCK @ MIDPT. OF EA. STAIR RUN STRINGER @ WALL (2) 16D @ 16" O.C. SCALE: 5/4" = l' - 0" RESUB Jan 12 2021 z VJ �� WICI o raj n W� � 3 ; p � U z • '"' o LA Q0 N 0 00 O LO V Z UNo O 00 Lu } Z m 0 c) Q � LL 2 � � Q U w Z Q p Q � Z Z oa mQ� w REVISIONS: PRINTED: 12/05/20 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEARWALL SCHEDULE SW EXP Notes apply as called out in table below. 1 Anchor bolts embedded at least 7", or expansion anchors embedded at least 4". See detail SWB. 2 #MASAP can be installed instead of sill bolts with washers. When replacing 1/2"0 sill bolts use 7-10dxll/2" nails (minimum nailing) and when replacing 5/s"O sill bolts use 9-10dxll/2" nails (maximum nailing). 3 See detail SWF. Connections vary depending on condition. 3a Substitute 16d toe nails @ 8"oc for #A35. 4 See detail SWR. Letter designations a, b, & c refer to specific conditions. For gable -end roof connections see detail SWF. 5 See detail SWB. 6 Abutting panel edges require a 2-2x (lamination connection same as WALL BASE PLATE), 3x, or greater stud. 8 The plate washer shall extend to within 1/2" of the edge of the bottom plate that receives the sheathing or rim. At double -sided shearwalls, stagger on both plate edges. SHEAR FLOW CONNECTIONS / SPACING S SILL -TO - FLOOR -TOROOF-TO - WALL BASE PLATE CALL FOUNDATION 1, 2 SILL & WALL3 WALL 4 5 OUT 5/8"0 @ 60"oc or #A35 @ #Hl @ 16d @ 10"oc A 1/2"0 @ 60"oc 48"oc 3a 24"oc 4a 5/8"0 @ 16"oc or #A35 @ #LS50 @ 16d @ 2"oc E 1/2"0 @ 12"oc 8 8"oc 8"oc 4b HOLDOWN SCHEDULE W WALL SHEATHING CALL OUT SHEATHING THICKNESS EDGE NAILS 6 7/16" 8d @ 6"oc 2 7/16" 6 8d @ 2"oc 1 Deepen the foundation as needed to provide the required holdown embedment into the foundation wall. See Detail MHE t 2 Fasten to the end framing members of the shearwall, u.n.o. 3 FOUNDATION ANCHOR may be extended with threaded rod and coupler as required. 4 Provide the minimum embedment and edge distances specified by the manufacturer. 5 Attach to (2) 2x studs minimum (lamination connection same as WALL BASE PLATE; stagger nails), u.n.o. 6 See detail HDN for installation. HOLDOWN / STRAP FOUNDATION 1,2,4,6 FASTENERS 5 ANCHOR 1,3,4,6 COMMENTS #MSTC661133 56-10d sinker N/A 4x6 Min Post. See detail SB #HTT5 26-10d 5/8"0 T.R. 8" min embed with SET epoxy in 6" min thick fdn wall SEE DETAIL EPX SYMBOL LEGEND SLEXP ---------------- DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM. DIAPHRAGM PROJECTION Represents elements such as roof eaves, facades, and the like. SHEARWALL Represents walls which are shearwalls and shows the extents of that wall. Connections per the SHEARWALL SCHEDULE. *HOLDOWN MODEL HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE. ® POST Indicates the location of a post within walls below framing. Sizes are indicated on the plan. Grades are indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BHS for posts not indicated on the plans. BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 2-2x6 (or 4x6) U.N.O. on the plan. JIL I HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL STRUCTURAL NOTES for the minimum size hanger. If a different model no. is required, it will be noted on the plan. JOIST, TRUSS, OR RAFTER Repetitive member symbol points in the direction of the span. The type, size and max spacing between members will be indicated in bold type with a symbol which is representative of the layout of the entire level. SYMBOL LEGEND - FOUNDATION SLEXP #HOLDOWN MODEL HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE. TIE -BEAMS See CONCRETE and REINFORCING BAR specifications per DETAIL TB. O PIPE PILE See PILE STRUCTURAL NOTES - specifications per DETAIL PP. F_ —]F2 L J SPREAD FOOTING See CONCRETE and REINFORCING BAR specifications per DETAIL FTG. PLAN INSTRUCTIONS READ THIS FIRST These plans are organized so that more detailed or specific information is found in the same way by following the direction shown below: GENERAL STRUCTURAL NOTES SCHEDULES, DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES for more specific information. SCHEDULES j�DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES and SCHEDULES for more ILII specific information. DETAILS j�PLANS will often refer to GENERAL STRUCTURAL NOTES, SCHEDULES and DETAILS for more ILII specific information. PLANS See the SYMBOL LEGEND as well as ABREVIATIONS AND ACRONYMS for other additional information used on the PLANS. The term, TYPICAL (or TYP), used with a detail callout or plan note, indicates that the information specified shall apply in all similar conditions. IF YOU HA VEA NY QUESTIONS OR CONCERNS CON TA CT US IMMEDIA TEL Y.! We can be reached immediately by phone: (425) 778-1023 For less pressing questions, email us: inbox@ssseng.com Please help us get to your plans by having this job number handy: s2009O29 ABBREVIATIONS AND ACRONYMS ABV ABOVE E. S. EACH SIDE O.C. ON CENTER A.B. ANCHOR BOLT E.W. EACH WAY P.T. PRESSURE TREATED BLW BELOW EA EACH REINF REINFORCEMENT ELK BLOCK E.N. EDGE NAILING REQD REQUIRED BLKG BLOCKING EMBED EMBEDMENT SCHED SCHEDULE B.N. BOUNDARY NAILING EXIST EXISTING SIM SIMILAR BTM BOTTOM FDN FOUNDATION STD STANDARD BRG BEARING FLR FLOOR STRUCT STRUCTURAL BTWN BETWEEN FRMG FRAMING SW SHEARWALL CLR CLEAR FTG FOOTING THRU THROUGH CLTR COLLECTOR G.T. GIRDER TRUSS TYP TYPICAL CONC CONCRETE GR GRADE U.N.O. UNLESS NOTED CONN CONNECTION HORIZ HORIZONTAL # OTHERWISE CONT CONTINUOUS MAX MAXIMUM VERT VERTICAL CTR CENTER MFG MANUFACTURED w/ WITH DBL DOUBLE MIN MINIMUM w/o WITHOUT DET DETAIL o/ OVER W.W.F. WELDED WIRE FABRIC E. E. EACH END oc ON CENTER DESIGN CRITERIA Governing Code 15 IBC Risk Category II Wind Design Data Basic Wind Speed (3 sec gust) mph 110 Surface Roughness D Wind Exposure Category D Earthquake Design Data Seismic Importance Factor, 1, 1.00 Site Classification D Short Period Acceleration, S, 1.299 1-Second Acceleration, S1 .51 Seismic Design Category D Spectral Response Coefficient, SIDS 0.866 Spectral Response Coefficient SD1 0.510 Gravity Load Data Internal Pressure Coefficient +/- 0.18 Topographic Factor, Krt 1.34 Wind Importance Factor, I 1.00 Seismic Force Resisting System ITable 12.2-1: A-15 2010 Equiv. Lateral Force Procedure Response Modification Factor, R 6.5 Transverse 6.5 Longitudinal Seismic Response Coefficient, C, 0.133 Transverse 0.133 Longitudinal Seismic Base Shear, V 18870 Ibs Roofs: loads are psf Dead Live Snow Rafters' •Solar-Ready3 20 0 25 Floors: loads are psf Dead Live Snow Joists, 12 40 0 Decks: loads are psf Dead Live Snow Joists-5 20 60 25 Notes apply as called out in table above. 1 Rafters of sawn lumber or wood I -joists. 3 Dead load includes 5psf for photovoltaic panels. 5 Joists of sawn lumber or wood I -joists. Soil Data Allowable Soil Bearing 2000psf] Com n : Earth Solutions NW, LLC IReport #: ES-7291 I Date: 9/9/20 PILE STRUCTURAL NOTES PIPE PILE INSTALLATION CEOTECHNICAL REPORT Earth Solutions NW LLC, ES-7291 Dated 9/9/2020 PIPE PILES 3" dia. Sch 40 Galvanized 12 Ton Capacity ASTM A-53 Type E or S, Grade B. Provide a 1/2x4x4 compression fit top plate on each pipe pile. Embedment into footing shall be 3" min and 5" max. TOLERANCE for locating piles is +/- 4". DRIVING CRIfERL4 850 lb hydraulic jack hammer until refusal - final penetration rate of at least 10 seconds per inch MIN. EMBED. minimum embedment shall be driven to refusal (estimated 20-25 ft) TESTING Not required by jurisdiction. OBSERVATION Geotechnical Special inspector shall be continuously present during pin pile installation. E% Jan 12 SSS Number: s2009O29 Project Name: 7824 175th St SW Owner: Michel Design Project Location: 7824 175th St SW, Edmonds, WA Design Professional: Michel Design M CV O Cn O rl 00 J � LU (r} L n J LU H Z c C La O IC pl R/] N 0 Z Ln � Ul) Z O � V) O U 0) C V7 V) �Ln X O C 04 UND � �pf wAs,�F'�p�� 14 "np 553[I5 `w4 ��QRAL S AL This space reserved for governing jurisdiction stamps ORIGIN DATE; 10/28/2020 REVISED; ---- S110U 021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GENERAL STRUCTURAL NOTES CODE All conditions, materials and construction shall conform to the code specified in the DESIGN CRITERIA, or other codes required by the governing jurisdiction. PROTECTION Through maintenance and current best practices, provide a building envelope that will preserve the integrity of the structure throughout it's lifetime. INSPECTIONS Notify Building Department for inspections required by local jurisdiction. SOILS Bearing capacity of soil shall be per DESIGN CRITERIA or greater. Footing shall bear on solid undisturbed level soil devoid of any organic material and below indicated frost line. COMPACTED FILL shall consist of predominately Well -Graded, granular soil, free of organic material and debris. Fill should be placed in maximum 8" loose lifts and compacted to a minimum of 95 percent of the maximum density at optimum moisture content determined by ASTM D-1557 test procedures. BACKFILL shall be free draining and without organic material and debris from one of the following soil classes SM-SC, SM, SP, SW, GC, GM, GP, and GW. FOUNDATIONS AND RETAINING WALLS Extend footings to undisturbed bearing soil. Do not backfill until all slabs and/or horizontal diaphragms are constructed, otherwise provide temporary bracing to resist movement. There shall be no machine compaction on the retaining side of the structure for a distance equivalent to 2/3rds the wall height. SILL PLATES Use pressure treated 2x plates u.n.o. Embed anchor bolts at least 7" (expansion anchors 4"). Use 3"x3"4.229" washers. There shall be a minimum of two bolts per piece spaced not more than 6 feet apart, with one bolt located not more than 12" or less than 4" from each end of each piece. CONCRETE f c = 3000 psi minimum for environmental exposure (2500 psi used in structural design, or unless greater psi indicated on the plans). 5 1/2 sacks of cement per cubic yard of concrete and a maximum of 6 gallons of water per 94 lb sack of cement. Maximum slump is 4". Segregation of materials shall be prevented through proper handling and placement. REINFORCING STEEL #4 bars and larger shall be Grade 60 deformed bars, and #3 bars shall be Grade 40 (u.n.o.), in accordance with ASTM A-615. Lap splices 32 bar diameters u.n.o. Welded wire fabric shall conform to ASTM A-185 and shall be 6x6 - W1.4xW1.4. Lap one full mesh at splices. CLEAR COVER 3" clr when cast against Earth and 2" clr in all other locations, u.n.o. See applicable detail(s): RI FOOTING DRAINAGE Footing drainage per Building Code section 1805.4.2 & Residential Code section R405.1. WOOD FRAMING in contact with concrete or masonry, or exposed to weather, shall be pressure treated. Numbers in parenthesis, IE (1-1), refer to corresponding engineering calculations. CONNECTORS AND FASTENERS Fasteners, including nuts and washers, and connectors in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. EXCEPTION Plain carbon steel fasteners, including nuts and washers, in SBX/DOT and zinc borate preservative treated wood in an interior, dry environment shall be permitted. SOLID SAWN LUMBER shall meet the following minimum grades (u.n.o.) conforming to "WWPA GRADING RULES FOR WESTERN LUMBER", latest edition: BEAMS, POSTS, RAFTERS, JOIST 6X and wider DF#1 4X DF#2 2x 10 and greater DF#2 2x 8 and smaller HF#2 WALL STUDS 2x HF#2 ENGINEERED WOOD shall meet the following minimum properties: Callout E x 106 (psi) Fb(psi) FC par(psi) Fc perp (psi) Fv(psi) LSL 1.55E 1900 2050 900 310 PSL 2.2E 2900 2900 625 290 Engineered wood products shall be protected from moisture to preserve their structural integrity. Provide temporary bracing to avoid permanent deflections resulting from drying under construction dead loads. I JOISTS Connect I -joist to plate using one 10d (0.131" x 3") nail on each side of bottom flange; drive nails at an agle at least 1 1/2" from end. Connect 1 1/4" LSL rim to I -joists with one 10d (0.131" x 3") nail into top and bottom flange. Full -depth blocking between joists over shearwalls shall be 1 1/4" min LSL. TRUSSES Manufactured trusses are a deferred submittal item designed per CODE section 2303.4 and shall be designed for all loads and load combinations per the CODE. All connections per manufacturer, u.n.o. If truss layout is changed by manufacturer, please notify this office. See applicable detail(s): GEB OVER -FRAMING Unless noted otherwise by truss manufacturer, overframe with 2x4 rafters @ 24" oc. Post down w/ 2x4 @ 48" oc, staggered. Brace posts over 6-0" tall perpendicular to wide face. WALL FRAMING & BEARING Walls shall be 2x studs at 16"oc max with double 2x top plate, and 2x base plate (exterior walls shall be 2x6 u.n.o. & interior walls shall be 2x4 u.n.o.). Party walls shall be parallel walls with a 1" gap between. Each wall shall be framed with 2x4 studs at 16"oc max with double 2x top plate, and 2x base plate. Block all supports solid to the foundation. See applicable detail(s): BHS TPS GENERAL STRUCTURAL NOTES continued WOOD STRUCTURAL PANELS shall meet the performance standards of the "APA" DOC PS1 and PS2 for their intended application (group 5 species not allowed). SHEARWALLS are indicated on the plans with a bold dashed line and labeled SW. The following letter designation refers to the Shearwall Schedule's SHEAR FLOW CONNECTIONS / SPACING table, and the number designation refers to the WALL SHEATHING table. Multiple combinations of letter and number designations may be present. Wall Line numbers, shown inside triangles, refer to corresponding engineering calculations. Attach rated sheathing (indicated below) to 2x min STUDS spaced no more than 16"oc, u.n.o. See Shearwall Schedule for minimum thickness and fasteners (thickness at point of fastened edges governs shear values). All panel edges shall be blocked. Nail intermediate supports @ 12"oc. Do not penetrate nails past flush. Install squash blocks under the ends of all shearwalls where the framing below does not provide full bearing. Construct cripple walls same as the shearwall above, and gable -ends same as the shearwall below. Rated sheathing: 7/16" OSB rated with a 24/16 span rating. 1/2" CD with a 32/16 span rating. See applicable detail(s): SWE ROOF DIAPHRAGM Install either OSB or CD sheathing: 7/16" OSB rated sheathing with a 24/16 span rating; panel clips required when spacing is greater than 20" oc. 1/2" CD rated sheathing with a 32/16 span rating. Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Nail all boundaries and supported edges with 8d @ 6"oc and interior supports with 8d @ 12"oc, blocking not required u.n.o. ROOF -TOP DECK DIAPHRAGM Install minimum 23/32" rated Sturd-I-Floor T&G with a 24oc span rating Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior supports with 10d @ 12" oc, blocking not required u.n.o. FLOOR DIAPHRAGM Install minimum 23/32" rated Sturd-I-Floor T&G with a 24oc span rating. Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior supports with 10d @ 12" oc, blocking not required u.n.o. COLLECTORS Diaphragms shall be nailed continuously to drag struts, drag trusses and other collector elements at boundary spacing, u.n.o. See applicable detail(s): DTC CS CONNECTIONS and fasteners shall be per CODE Table 2304.10.1 u.n.o. The symbol, #", indicates a hardware connector from the most current Simpson Strong -Tie Catalog. Hardware with equivilent or greater capacities from other manufacturers may be substituted, example you can use USP's Dual Specification Chart to make an equivilent or greater capacity selection. Install per the manufacturer instructions. Fasteners and hardware in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. NAILS All nails shall be "Standard Common" size per the latest edition of the National Design Specification for Wood Construction (NDS) u.n.o. HOLDOWNS See the HOLDOWN SCHEDULE. See applicable detail(s): HDN HOC POST CAPS Provide a post cap on isolated columns that most nearly matches the actual member size(s) U.N.O. Each connection shall have a minimum of (3)10d to the post and (3)10d to the beam. HANGERS Model numbers will be specified on the plans for conditions that require more than minimum capacity, otherwise see CONNECTIONS. When a hanger is not specified on the plans, use any size specific model number that fits that member. Always use MAX NAILING. Hanger to match member size. Notching or shimming of beam not allowed unless specified. JOBSITE SAFETY Sound Structural Solutions Inc has not been retained or compensated to provide design and/or construction review services related to the contractor's safety precautions or to means, methods, techniques, sequences or procedures for the contractor to perform their work. The undertaking of periodic site visits by the ENGINEER shall not be construed as supervision of actual construction and not make him responsible for providing a safe place for the performance of work by the contractor, subcontractors, suppliers or their employees, or for access, visits, use work, travel, or occupancy by any person. OWNERSHIP OF DOCUMENTS These drawings and calculations are the intellectual property of Sound Structural Solutions Inc. These drawings may not be used in whole or in part by any person without permission of Sound Structural Solutions Inc. MISCELLANEOUS The contractor shall verify dimensions and conditions at job site. The contractor shall provide temporary bracing as required until all permanent connections and stiffenings have been installed. Do not scale drawings. Pre -fabricated items to be handled and installed per manufacturer's recommendations. RE Jan 12 SSS Number: s2009O29 Project Name: 7824 175th St SW Owner: Michel Design Project Location: 7824 175th St SW, Edmonds, WA Design Professional: Michel Design M (V O Cn O rl 00 J � LU [f} Ln J LU Z c C La 0 IC pl R� Q) p Z U) U) Z O � V) O U 1 C Np V7 U) �U) X O C �14 ON0 � �pf wAs,�F'�p�� "n1,p 55305 `w4 AL�' r AN( L This space reserved for governing jurisdiction stamps ORIGIN DATE; 10/28/2020 REVISED; ---- Sill 021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (8)16d EVENLY SPACED, TYP U.N.O. 16d @ 16" oc TYP FACE NAILS I � I I I I 4'-0" MIN SPLICE ~I TOP PLATE SPLICE DOUBLE TOP PLATE SPLICE N.T.S. ROOF DIAPHRAGM PER STRUCT NOTES EDGE NAILS SOLID #H2.5A MIN BLKG @ ALL ROOF WALL MEMBERS U.N.O. @ SHEARWALLS SHEARWALL w/ TRUSS OR RAFTER BEARING a SWkI SHEARWALL ROOF CONNECTIONS MIN 2x DISCONTINUOUS DBL TOP PLATE POST N.T.S. DIAPHRAGM PER STRUCT NOTES FLR RIM/BLKG (OR ROOF GABLE) NAILS PER SW SCHED WALL BASE PLATE CONN SOLID BLKG OR COLLECTOR BEAM #CS16 w/, (13) 8d NAILS EA END DISCONTINUOUS DBL TOP PLATE #LS50 @ SHEARWALLS PER SCHED LLS EDGE NAILS (SW ABOVE) L'I TPSA #H2.5A @ ALL ROOF MEMBERS WALL BASE PLATE CONN (SW ABOVE) DIAPHRAGM PER STRUCT NOTES RIM/BLKG EDGE NAILS1-7 PROVIDE #A35 PER EDGE NAIL PROVIDE BLK'G @ 48"oc SW SCHED (SW BELOW) BLKG @48" oc w/ JOIST -WALL DOUBLE -SIDED SHEARWALLS w/ JOIST -WALL PARALLEL , PARALLEL INTERIOR SHEARWALLS, & EXTERIOR SHEARWALLS EXT SHEARWALLS @ CANTILEVERS SHEARWALL TO FLOOR TO SHEARWALL SWF SHEARWALL FLOOR CONNECTIONS N.T.S. WALL ANCH PER SW SCHED 2x SILL U.N.O. PER SW SCHED FDN SHEARWALLS TO FOUNDATION WALL BASE PLATE CONN PER SW SCHED RIM/BLKG EDGE NAILS FDN WALL DIAPHRAGM PER STRUCT NOTES ANCH PER SW SCHED 2x SILL U.N.O. PER SW SCHED SHEARWALLS TO FLOOR TO FOUNDATION SWB I SHEARWALL BASE PLATE & FOUNDATION CONNECTIONS N.T.S. SWRA SWFA BOUNDARY NAIL ALONG LENGTH OF COLLECTOR COLLECTOR BOUNDARY NAIL ALONG LENGTH OF DIAPHRAGM PER STRUCT NOTES INTERMEDIATE FRAMING ABUTTING PANEL EDGES DIAPHRAGM TO COLLECTOR N.T.S. BOUNDARY NAIL ALONG LENGTH OF COLLECTOR 2X BLOCKING #A35 @ 48" oc MAX, U.N.O BETWEEN JOISTS DROPPED BEAM f / \ DROPPED CONDITION DTCA "rnn1 & #CS16 6)10d 10WN REQD STUDS REQUIRED STUDS BEAM 2x4 WALL 2x6 WALL 4x & 2-2x (SAWN) 3%x (GLB) (2) 2x4 (2) 2x6 3%x (MANF) 6x & 3-2x (SAWN) 5%x (GLB) (3) 2x4 (3) 2x6 5Y4x (MANF) 8x (SAWN) 6Y44x (GLB) (4) 2x4 (4) 2x6 7x (MANF) GIRDER TRUSS (3) 2x4 (3) 2x6 REQUIRED TRIMMERS HEADER 2x4 WALL 2x6 WALL 4x & 2-2x (SAWN) 3%x (GLB) 2x4 2x6 3%x (MANF) 6x & 3-2x (SAWN) 5%x (GLB) ---- (2) 2x6 5 ax (MANF) REQD TRIMMERS NOTE: BEAR BEAMS ON THE FULL WIDTH AND BREADTH OF THE MINIMUM SUPPORTS PER TABLES ABOVE UNLESS NOTED OTHERWISE ON THE PLANS BHS BEAM & HEADER SUPPORTS N.T.S. EXTENT OF SHEARWALL CRIPPLE STUD DOUBLE TOP PLATE TPS SWF SWR HEADER HEADER WINDOW OPENING DOOR ENI KING STUD TRIMMER STUD 4" x 4" IS THE MAXIMUM PENETRATION CRIPPLE STUD BASE PLATE SWB SWF OR HOLE THAT CAN BE ADDED TO A SHEARWALL SWE I SHEARWALL ELEVATION N.T.S. EXTENT OF SHEARWALL DR9RE Jan 12 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SSS Number: s2009O29 Project Name: 7824 175th St SW Owner: Michel Design Project Location: 7824 175th St SW, Edmonds, WA Design Professional: Michel Design M N Q 0 O 1--1 0 H J � uU Lon Ln N pJ w z E V O » L o z w E O p) C N cn u) O U WA 55305 It L`tt►�AL`'� '1 rONAIL This space reserved for governing jurisdiction stamps ORIGIN DATE: REVISED: 10/28/2020 ---- S210U 2021 N O 0 O N [/7 C NI N O O 0 N #MTS20 MIN w/ MIN (7)10d x 1%" TO EA MEMBER U. N.O. COLLECTOR COLLECTOR OR RIM TOP PLATE TOP PLATE COLLECTOR TO TOP PLATE N.T.S. DECK BEAM PER PLAN #BC CAP/BASE BEAM TO BEAM #MTS30 MIN w/ MIN (7)10d x 1%" TO EA MEMBER U. N.O. CTPD DROPPED BEAM BB BEAM BEARING ON BEAM N.T.S. 2X BLOCKING/FL DROPPED BEAM STRAP WRAP STRAP AS REQD SB I STRAP TO BEAM N.T.S. SBAB 6" TYP 1'/z" 1 11 1% SPACING TYO 1 1 1 EDGE DIST TYP 1 % " EDGE DIST TYP 0 0 o i o 0 0 —t— 3" SPACING TYP EXISTING SLOPED o 0 0 o o ----- SOLID RIM (2) 2X RIM 5 SLOPED FLOOR (12) /6 HOLES DECKING BY OTHERS BEND IN PLATE SLOPED 4X FACIA a X 6 X 12" STEEL PLATE LEDGER ELEV. CTR OF RIM 8" TYP, 1 8" TYP. 1 MIN. 16 %" 0 x 4" #SDS %" BENT STEEL PLATE w/ 2 MAX. TYP. SCREWS @ 8" oc (NOT SLOPED) 4X (12) #SDS % X 4 %" 2x(MATCH JOIST) P.T. LEDGER COLLECTOR SCREWS, TYP (6) SCREWS IN EACH VA ADJACENT MEMBER EDL I EXTERIOR DECK LEDGER FTWEI THREE-WAY COLLECTOR CONNECTION @ ROOF N.T.S. EDLB I I N.T.S. #LSTA24 w/ MIN (9) -10d FASTEICDC DED KAEKADED DROPPED BEAM TRIMMERS I — — w.. Inn DI AT[ CTP2 I COLLECTOR TO TOP PLATE N.T.S. CTPF 12" MIN 1 48" MIN CS16 TO OLLECTOR & BLOCKING DIAPHRAGM G CSB COLLECTOR SPLICE TO BLOCKING LJ N.T.S. #LSTA24 w/ #LSTA24 w/ MIN (9) -10d MIN (9) - lOd x 1 FASTENERS PER MEMBER %" U.N.C. DIAPHRAGM FASTENERS PER MEMBER DIAPHRAGM U.N.O. COLLECTOR I COLLECTOR I I I COLLECTOR I/ \1 COLLECTOR SPLICE L OPTIONAL STRAP LOCATION BEAM COLLECTOR SPLICE N.T.S. A-12 DBL 2x STUD EDGE NAILING \ Ir— SW SHEATHING HOLDOWN EMBEDDED STRAP STRAP SHOWN AROUND CORNER STUDS PER HOLDOWN SCHED EDGE NAILING 2x STUD HOC I HOEDOWN AT CORNER N.T.S. HOCA CSAC MSTC STRAP IT7- 7STRAP MAY BE LOCATED ON INSIDE MSTC STRAP -(A) HTT5- A FHDN HOLDOWNS L—i N.T.S. HRES Jan 12 SSS Number: s2009O29 Project Name: 7824 175th St SW Owner: Michel Design Project Location: 7824 175th St SW, Edmonds, WA Design Professional: Michel Design M �} Ln N O Q H J i./) LU LP) N z E O V v � � N C z cn Loon E O U 0) C N U) V) U) O C TA ULW WAS ` 55305 '� + AL�- NAt This space reserved for governing jurisdiction stamps ORIGIN DATE: 10/28/2020 REVISED: ---- S2,1 U 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT STEEL GUARD POST SPACED @ 48"oc MAX (4)%"0 x 8" LAG SCREWS 6x6 GUARD POST PEDESTAL WATER -PROOFING BY OTHERS GUARD POST ATTACHMENT (6)1/a x 3 % #SDS, TYP ••• 2x10]OIST ••• �•. •.. %" MIN, TYP STEEL PLATE %" x 5" x 5" CENTFn�n nni c.,c q" TYP GPA OR PD 6x6 2x RIM ", TYP SECTION A (4) %6"� HOLES DESIGN NOTE MANUFACTURER SHALL PROVIDE A SYSTEM THAT IS DESIGNED TO RESIST THE FOLLOWING LOADS; GUARD RAIL POST - 200 LB CONCENTRATED LOAD IN ANY DIRECTION AT TOP TOP RAIL - 200 LB CONCENTRATED LOAD IN ANY DIRECTION AT ANY POINT GUARDRAIL INFILLCOMPONENTS - 50 PSF APPLIED HORIZONTALLY NORMAL TO THE INFILL (2)10d EACH BOARD ins ina n cni rr� 1 GUARD POST TO JOIST OR RIM PD PARAPET ATTACHMENT O PD (4) 14 x 3% #SDS, TYP GPA OR PD (4)% x 8 #SDS, TYP GPA OR PD 6x6 10d @ 4" oc 6x6 2xJOIST • • RIM • • � OR BLOCKING • • P ,� • •— %" MIN, TYP 1 % LVL BLOCKING w/ #U210 EA END BEAM � 2/" TYP DO %" MIN, TYP 2 GUARD POST TO BLOCKING 3 GUARD POST TO BEAM GUARD POST PEDESTAL -NOMINAL 10" SOLID SAWN N.T.S. BOUNDARY NAILS PER N(`T�` 30° P SHEATHING PER NOTES 2x FLAT BLK w/ DBL ROW OF BOUNDARY NAILS TRUSS 2x4 BRACE @ 48"oc w/ #A35 AT BTM GEB GABLE -END TRUSS BRACE N.T.S. DO NOT NOTCH NOTE: ALL POSTS REQUIRE CONNECTIONS ON TWO FACES PER DIAGRAM SHOWN ABOVE GEBA ;KING XO 6x6 POST, DO NOT NOTCH 2x RIM RE Jan 12 SSS Number: s2009029 Project Name: 7824 175th St SW Owner: Michel Design Project Location: 7824 175th St SW, Edmonds, WA Design Professional: Michel Design M �} � (V o o � H � � J � �� � Ll') f V J � � � O V � v � � N � � C z � O � O U p1 C a� 0 C '�,P'� 'U�1) 4� W�S,���.y +� C+ t..0 �" �• �' "�,p 5530� �� a ���AL ���'��� ,t��� �',�`�f�N�� ��Cs � � �. This space reserved for governing jurisdiction stamps ORIGIN DATE: 10/28/2020 REVISED: ---- U � 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FOOTING SCHEDULE CENTER UNDER CONCENTRATED LOAD U.N.O. FOOTING S]ZE REINFORCEMENT ID WIDTH (Transverse) LENGTH (Longitude) THICIWESS LONGITUDE TRANSVERSE F1.5 1'-6" 1'-6" 8" (2) #4's (2) #4's F2 2'-0" 2'-0" 10" (3) #4's (3) #4's F2.5 2'-6" 2'-6" 10" (3) #4's (3) #4's LONGITUDE REINF TRANSVERSE REINF � Pif1CT Tf1 Frif; THICKNESS LENGTH PER PLAN WIDTH PER PLA (LONGITUDE) (TRANSVERSE) �/ � PLYNTH ON FTG FOOTING, TYPICAL N.T.S. FTG @WALL FTG @WALL CORNER FTGA GR BEAM �nnTr�i�� � REINF MATCH HORIZ �.o STD 90° HOOK INTO REINF INTERSECTING GR BEAM 1�-6�� CORNER BAR @ALL OUTER REINF • REINF . I WALLS STD 90° HOOK INT MATCH HORIZ INTERSECTING GR BEAM REINF ALTERNATE EA BAR 1�_6�� CORNER BAR @ALL OUTER REINF REINFORCEMENT AT INTERSECTIONS N.T.S. RIAA PLINTH 8" MIN 18" MAX 2" MIN FINISH GR \�� � i`` .. /� (2) #4 @ w� STD lg�� HOOK IN FTG MIN 48" MAX FTG 3" CLR �_ � BRG SOIL � ' PEDESTAL ON ISOLATED FOOTING N.T.S. 14" MIN 12" MIN 18" MIN REM REMODEL VERIFICATION N.T.s. REM HOEDOWN ANCHOR e FOUNDATION WALL MINIMUM STEM HEIGHT REQUIRED TO ACCOMMODATE ANCHORAGE PER HOEDOWN SCHEDULE — � FOOTING L___ PIFA e HOEDOWN e ANCHOR e EMBEDDED STRAP � �/ � �/ � � � EMBEDDED STRAP I�� lil i DEEPEN FOUNDATION AS REQD TO ACCOMODATE FOR HOEDOWN EMBEDMENTS INTO WALL MHE I MINIMUM HOEDOWN EMBEDMENT N.T.S. I�IE Jan 12 SSS Number: s2009029 Project Name: 7824 175th St SW Owner: Michel Design Project Location: 7824 175th St SW, Edmonds, WA Design Professional: Michel Design M [.!3 � (V O O ,--i � H � � J C [!? � � fV � � ,�J z � O V � � � o � `� � Lin O U p1 C N 0 c 4, p,t� ONE +.w `� un�, 553Q8 ��'��'�,� �� � �c�ce �RAL�'��� �� �� �'"4 This space reserved for governing jurisdiction stamps ORIGIN DATE: 10/28/2020 REVISED: ---- U � 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SYMBOL LEGEND SLEXP See sheet Si. vvlvvr-�iivly rv-►Iv —_- 3/16" = 1�-O�� DO NOT SCALE -VERIFY ALL DIMENSIONS WITH ARCHITECTURAL SHEETS PRIOR TO CONSTRUCTION RED Jan 12 SSS Number: s2009029 Project Name: 7824 175th St SW Owner: Michel Design Project Location: 7824 175th St SW, Edmonds, WA Design Professional: Michel Design M ;,/ } � N O Q ,-� 1--i H � � � J n i!) � � � N � � pJ� z � O V �_ � � H � � � � u7 p Z z � � � O V pl C N �� X O C '4 '�� � �� � � c� � `��„� 5534a "�� � �� ��� This space reserved for governing jurisdiction stamps ORIGIN DATE: 10/28/2020 REVISED: ---- U � 2021 f"V O O 0 c'V N I c a cn cn cn i f'V f"V O Q� O 0 ('V CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT �zry WALL LINE WALL LINNE TO RIM S � X 18" DROPPED (24F-V8) GLB (1-11) P.T. 6X6 POST wl #CCQ @TOP *ABU @BTM P.T. 6X6 POST wl Gpp CS J �) � *ECCQ @TOP S � X 10 �' GLB DROPPED (1-12a) S � X 10 �"GLB DROPPED (1-12b) BB P.T. 6X6 POST wl DTC 3 STUDS MIN, VIF *CCQ @TOP ( ) #ABU @BTM GPP TVP EDL J L TO EXISTING �S CTP TO EXISTING DOUBLE RIM, VERIFY IN FIELD TOP PLATE, VIF SYMBOL LEGEND SLEXP See sheet S1. WALL LINE C WALL LINE D WALL LME E GPP P.T. 6X6 POST wl P.T. 6X6 POST wl *CCQ @TOP #CCQ @TOP #ABU @BTM *ABU @BTM S % X 18" (24F-V8) DROPPED GLB (1-6) P.T. 6X6 POST wl *CCQ @TOP Gpp � r CSB P.T. 6X6 POST wl #ABU @BTM v #ECC @TOP Q N i *ABU @BTM S� X 9"GLB DROPPED (1-la) S� X 9"GLB DROPPED (1-lb) o � �� J � o0 CTP2 � (8) STUDS MM, VIF � TO LEDGER CSB � � o � � 0 v EXISTING CONDITIONS THE FOLLOWING FRAMING ASSUMPTIONS WERE MADE IN OUR DESIGN SPAN DIRECTION AND CONSTRUCTION OF ROOF AND FLOOR FRAMING SIZE AND SPACING OF STUD WALLS � PRESENCE OF STEM WALL AND FOOTINGS THESE ARE REASONABLE ASSUMPTIONS BASED ON PHOTOGRAPHS, DESIGNER DOCUMENTATION AND TYPICAL CONSTRUCTION STANDARDS. IT WILL BE NECESSARY, HOWEVER, TO VERIFY THESE ELEMENTS DURING DEMOLITION WHEN FURTHER OBSERVATIONS CAN BE MADE. THIS OFFICE IS AVAILABLE TO PARTICIPATE SHOULD THE SITUATION BECOME COMPLICATED. THE STRUCTURAL MEMBERS AND ASSEMBLIES SHALL BE CONSTRUCTED AS SPECIFIED ON THE PLANS. EXISTING CONSTRUCTION IS ADEQUATE WHERE IT MEETS OR EXCEEDS THE MATERIAL GRADES AND SPECIFICATIONS WE PROVIDED THROUGH PLANS, DETAILS AND GENERAL NOTES. WHERE EXISTING CONDITIONS OR OUR PROPOSED CONSTRUCTION DIFFERS, THEN, EITHER CONSTRUCT AS SHOWN ON OUR PLANS OR CONTACT THIS OFFICE TO DISCUSS OPTIONS, FAMILY RUUM BASEMENT SHEARWALLS &FRAMING ABOVE 3�16" = 1'-0" TO EXISTING DOUBLE TOP PLATE, VIF W LL f5 #�115 #HUC EDL CTP2 TO END OF DECK TYF S � X 9" LEDGER SW GLB DROPPED (1-14) E2 -------- 4X4 wl 4X4 STUD 4X4 STUD *ECCQ @TOP P.T 6X6 POST wl K CS #CCQ @TOP #ABU @BTM x — (8) STUDS MIN VIF (B) STUDS MIN, F EDL sIM EDL Y ���= �� GPP GPP og�a �"�� P.T. 4X10 DROPPED P.T. 4X4 POST wl Gpp P.T. 4X4 POST wl #EPCZ @TOP *EPCZ @TOP #ABU @BTM #ABU @BTM DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS CTP TO EXISTING DOUBLE TOP PLATE, V[F RE Jan 12 SSS Number: s2009029 Project Name: 7824 175th St SW Owner: Michel Design Project Location: 7824 175th St SW, Edmonds, WA Design Professional: Michel Design M ;,/ } � N � Q rl Hi � 00 � J i!) � �� � N Z (] V � i--I V �1 � � � � Z Z � �) � 0 V pl C N �� X O C f'� ��� �� ��� �� �� `n�,p 5�30� `"`k � ��. �,g� This space reserved for governing jurisdiction stamps ORIGIN DATE: 10/28/2020 REVISED: ---- U � 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT �zry SYMBOL LEGEND SLEXP See sheet S1. L[^E LIBNE W�E WIDNE LIFE 3�16" = 1'-0" DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS RES Jan 12 SSS Number: s2009029 Project Name: 7824 175th St SW Owner: Michel Design Project Location: 7824 175th St SW, Edmonds, WA Design Professional: Michel Design M ;,/ } � N O Q ,-� 1--i H � � � J n i!) � � � N � � pJ� z � O V �_ � � H � � � � u7 p Z z � � � O V pl C N �� X O C f'� ��� �� ��� �� �� `n�,p 5�30� `"`� � ��. �,g� This space reserved for governing jurisdiction stamps ORIGIN DATE: 10/28/2020 REVISED: ---- U � 2021 f"V O O O c'V N I c ca a cn cn cn I f'V f"V O Q� O 0 ('V CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT