Loading...
APPROVED BLD BLD2022-0626+Architectural_Plan+5.12.2022_1.32.45_PM+2866370PROJECT NOTES TYPICAL ABBREVIATIONS PROJECT CODE SUMMARY DRAWING INDEX 1. WORK OF THE CONTRACT INCLUDES THE 14. CONTRACTOR SHALL MAINTAIN SITE IN A STATE OF FURNISHING OF ALL MATERIALS, LABOR, EQUIPMENT, CLEANLINESS THROUGHOUT THE DURATION OF THE TOOLS, TRANSPORTATION, INSURANCE, SALES TAXES, PROJECT. PERMITS, LICENSES, SUPERINTENDENT AND MISCELLANEOUS SERVICES REQUIRED FOR THE 15. PAVED SURFACES INCLUDING ROADWAYS, CONSTRUCTION AND COMPLETION OF THE PROJECT AS SIDEWALKS, AND CURBS THAT ARE DAMAGED BY NEW REQUIRED BY THE PLANS AND SPECIFICATIONS. CONSTRUCTION SHALL BE REPAIRED AS REQUIRED BY THE STREET USE INSPECTOR. 2. ALL WORK SHALL CONFORM TO THE CONTRACT DOCUMENTS WHICH INCLUDE THE DRAWINGS, ALL 16. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ADDENDUMS AND MODIFICATIONS ISSUED BY THE HEREIN HAVE BEEN ESTABLISHED BY A FIELD SURVEY ARCHITECT. OBTAINED FROM AVAILABLE RECORDS AND SHOULD BE CONSIDERED APPROXIMATE ONLY AND NOT 3. ALL WORK DONE UNDER THIS CONTRACT SHALL NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY CONFORM TO ALL APPLICABLE CODES, ORDINANCES OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE AND GOVERNMENT REGULATIONS HAVING ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO JURISDICTION OVER THE WORK. FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREIN WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. 4. ANY SPECIFIC REFERENCE TO CODES, RULES, REGULATIONS, STANDARDS, MANUFACTURER'S 17. THE CONTRACTOR SHALL LOCATE AND PROTECT ALL INSTRUCTIONS OR REQUIREMENTS OF REGULATORY CASTINGS AND UTILITIES DURING CONSTRUCTION AND SHALL MEAN THE LATEST PRINTED EDITION OF EACH IS SHALL CONTACT THE UNDERGROUND UTILITIES LOCATOR IN EFFECT AT THE DATE OF SUBMISSION OR BID UNLESS SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO THE DOCUMENT IS SHOWN DATED. CONSTRUCTION. 5. A COPY OF THE APPROVED PLAN MUST BE ON SITE 18. UTILITY SERVICE CONNECTIONS SHOWN ARE TO BE WHENEVER CONSTRUCTION IS IN PROGRESS. MAINTAINED PRIVATELY AND NOT BY THE CITY OF SEATTLE. 6. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THE 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN STREETS WILL NOT BE ALLOWED WITHOUT PRIOR TEMPORARY SEDIMENTATION COLLECTION FACILITIES TO APPROVAL. INSURE THAT WATER DOESN'T ENTER THE NATURAL OR PUBLIC DRAINAGE SYSTEM. AS CONSTRUCTION 7. INTERPRETATIONS -THESE DOCUMENTS ARE IN PROGRESSES AND UNEXPECTED (SEASONAL) PART DIAGRAMMATIC AND SUBJECT TO CONDITIONS DICTATE, MORE SILTATION CONTROL INTERPRETATION. THEY DO NOT NECESSARILY SHOW FACILITIES MAY BE REQUIRED TO INSURE COMPLETE COMPLETE DETAILS OF CONSTRUCTION, WORK OR SILTATION CONTROL OF THE PROJECT. THEREFORE, MATERIALS, OR INSTALLATION, AND DO NOT DURING THE COURSE OF CONSTRUCTION IT SHALL BE NECESSARILY SHOW HOW CONSTRUCTION DETAILS OF THE OBLIGATION AND RESPONSIBILITY OF THE OTHER WORK MAY AFFECT ANY PARTICULAR CONTRACTOR TO ADDRESS ANY NEW CONDITIONS THAT INSTALLATION. MAY BE CREATED BY HIS/HER ACTIVITY AND TO PROVIDE ADDITIONAL FACILITIES THAT MAY BE NEEDED TO 8. DIMENSIONS -THE DRAWINGS MAY NOT BE DRAWN PROTECT ADJACENT PROPERTIES. SEE THE DRAINAGE TO SCALE IN SOME INSTANCES; FOLLOW DIMENSIONS CONTROL PLAN FOR MORE INFORMATION. BUT DO NOT SCALE THE DRAWINGS: WHERE DIMENSIONS ARE NOTED "CONFIRM" OR "VERIFY", 20. ALL WORK PERFORMED BY PUBLIC UTILITY ENTITIES CONSULT THE ARCHITECT FOR DIMENSION CRITERIA TO REMOVE OR RELOCATE EXISTING UTILITIES SHALL BE BEFORE PROCEEDING WITH THE WORK. ALL DIMENSIONS DONE AT THE PERMITEE'S EXPENSE. ARE GIVEN TO THE FACE OF FINISH MATERIALS, UNLESS OTHERWISE NOTED. 21. A SIGNED AFFIDAVIT DOCUMENTING ANY REQUIRED COMMISSIONING SHALL BE PROVIDED TO THE BUILDING 9. THE GENERAL CONTRACTOR (GC) SHALL REVIEW ALL INSPECTOR PRIOR TO AN APPROVED FINAL INSPECTION. DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND SHALL CONFIRM THAT WORK IS 22. UPON SUBSTANTIAL COMPLETION, THE BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSIONS, CONTRACTOR SHALL PROVIDE FINAL CLEANING FOR ETC., SHALL BE IMMEDIATELY REPORTED TO THE EACH AREA WHICH WILL RESULT IN A LEVEL OF ARCHITECT FOR CLARIFICATION PRIOR TO THE CLEANLINESS CLEANING SHALL INCLUDE, BUT IS NOT PERFORMANCE OF ANY WORK IN QUESTION. THE GC LIMITED TO: GLASS, CARPET, PLASTIC LAMINATE, LIGHT SHALL ARRANGE FOR INSPECTIONS NECESSARY TO FIXTURES AND REMOVAL OF LABELS (NOT REQUIRED TO OBTAIN A CERTIFICATE OF OCCUPANCY. BE PERMANENT BY CODE). CONTRACTOR SHALL SCHEDULE FINAL CLEANING SO OWNER MAY OCCUPY 10. IN CASE OF CONFLICT BETWEEN ARCHITECTS AND COMPLETELY CLEAN PROJECT. CONSULTANTS DRAWINGS IN LOCATING MATERIALS/EQUIPMENT, THE ARCHITECT SHALL BE 23. ALL MATERIALS AND EQUIPMENT SHALL BE NOTIFIED FOR CLARIFICATION. INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE 11. SUBSTITUTIONS, REVISIONS, OR CHANGES MUST BE ASSOCIATES ACCEPTED STANDARDS. SUBMITTED TO ARCHITECT FOR REVIEW (IN CONFORMANCE WITH SPECIFIED PROCEDURES) PRIOR 24. CONTRACTOR SHALL PROVIDE A WRITTEN TO PURCHASE, FABRICATION, OR INSTALLATION. IT IS CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL THE RESPONSIBILITY OF THE GC TO COORDINATE INCLUDE DELIVERY TIMES OF CONSTRUCTION ITEMS, ORDERS, SUBMITTALS AND IMPLEMENTATION OF LONG AND START AND COMPLETION DATES OF EACH PHASE. LEAD ITEMS. SUBSTITUTIONS WILL NOT BE CONSIDERED THE CONTRACTOR SHALL UPDATE AND PROVIDE THIS RESULTING FROM THE GC'S FAILURE TO MAKE LONG SCHEDULE ON A BI-WEEKLY BASIS. LEAD ITEM ORDERS IN A TIMELY FASHION. WHERE DELAYS MAY OCCUR DUE TO AN ITEM NOT BEING 25. GENERAL CONTRACTOR IS RESPONSIBLE FOR ORDERED IN A TIMELY FASHION, GENERAL CONTRACTOR PROVIDING ALL NECCESSARY BACKING, BLOCKING, AND SHALL PROVIDE, AT HIS COST, A TEMPORARY FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES, REPLACEMENT AND THEN CHANGE OUT TO THE CASEWORK, PLUMBING FIXTURES, GRAB BARS AND ALL SPECIFIED ITEM UPON ARRIVAL/DELIVERY. OTHER ITEMS REQUIRING IT. 12. ALL MANUFACTURED ARTICLES, MATERIALS AND 26. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS ERECTED, CLEANED, AND CONDITIONED PER MFR.'S IF DRAWN IN FULL. INSTRUCTIONS. IN CASE OF DIFFERENCES BETWEEN THE MANUFACTURER'S INSTRUCTIONS AND CONTRACT 27. ANY AND ALL DESCREPANCIES FOUND BETWEEN DOCUMENTS, THE GC SHALL NOTIFY THE ARCHITECT FIELD CONDITIONS AND DRAWINGS OR WITHIN THE BEFORE PROCEEDING. DRAWING SET ARE TO BE BROUGHT TO ARCHITECTS ATTENTION IMMEDIATELY, PRIOR TO CONTINUING 13. ALL MATERIALS DELIVERED TO THE JOB SITE SHALL WORK. BE PROPERLY STORED WITHIN THE PREMISES OR AT A LOCATION DESIGNATED BY BUILDING OWNER. DELIVERY, HANDLING AND STORAGE OF PRODUCTS SHALL BE IN A MANNER TO PREVENT DAMAGE, DETERIORATION, LOSS OR THEFT. SYMBOL LEGEND N NORTH ARROW z CD REVISION CLOUD Room name 123 ROOM TAG 1 1 A101 1 EXTERIOR ELEVATION REFERENCE 1 1 1 A1.0 1 INTERIOR ELEVATION REFERENCE 1 & AND FBR FACE BRICK (N) NEW @ AT FD FLOOR DRAIN NA NOT APPLICABLE STC SOUND TRANSMISSION # POUND/ NUMBER FDN FOUNDATION NIC NOT IN CONTRACT COEFFICIENT ABV ABOVE FDV FIRE DEPARTMENT VALVE NO NUMBER STD STANDARD ACOUS ACOUSTICAL FE FIRE EXTINGUISHER NOM NOMINAL STL STEEL ACT ACOUSTICAL CEILING TILE FGS FOAM GASKET SEAL NRC NOISE REDUCTION COEFFICIENT STN STONE ADD ADDENDUM FH FIRE HOSE NT NOTE STOR STORAGE ADDL ADDITIONAL FHC FIRE HOSE CABINET NTS NOT TO SCALE STRUCT STRUCTURAL ADJ ADJUSTABLE/ADJACENT FHV FIRE HOSE VALVE OC ON CENTER STS STEEL STRUCTURE ADMIN ADMINISTRATION FIN FINISH OD OUTSIDE DIAMETER SW STEEL WINDOWS AFF ABOVE FINISH FLOOR FIXT FIXTURE OFCI OWNER FURNISHED - SW SWITCH AHU AIR HANDLING UNIT FL FLOOR CONTRACTOR INSTALLED SWD SOFTWOOD ALT ALTERNATE FLASH FLASHING OFF OFFICE SYM SYMMETRICAL ALUM ALUMINUM FLEX FLEXIBLE OH OVERHEAD T TOP ANUN ANUNCIATOR FLG FLANGE OP OPERABLE PARTITION TAN TANGENT AP ACCESS PANEL FLUOR FLUORESCENT OPNG OPENING TBD TACKBOARD APROX APPROXIMATE FOIC FURNISHED BY OWNER- OPP OPPOSITE TC TIME CLOCK ARCH ARCHITECTURAL/ ARCHITECT INSTALLED BY CONTRACTOR ORD OVERFLOW ROOF DRAIN TCAB TOWEL CABINET BD BOARD FP FIRE PROOFING PART PARTITION TDISP TISSUE DISPENSER BFE BOTTOM FOOTING ELEVATION FRMG FRAMING PC PRECAST CONCRETE TDR TRENCH DRAIN BG BUMPER GUARD FS FLOOR SINK PED PEDESTAL TEL TELEPHONE BLDG BUILDING FSTOP FIRESTOPPING PL PROPERTY LINE TEMP TEMPERATURE BLKG BLOCKING FT FOOT/FEET PLAM PLASTIC LAMINATE TER TERRAllO BLW BELOW FTG FOOTING PLBG PLUMBING T&G TONGUE & GROOVE BM BEAM FURR FURRING PLS PLASTER THRES THRESHOLD BO BOTTOM OF FUT FUTURE PLW PLYWOOD TPH TOILET PAPER HOLDER BOT BOTTOM GA GAUGE PNL PANEL TR TREAD BR BRICK GAL GALLONS PR PAIR TRANSF TRANSFORMER BSMT BASEMENT GALV GALVANIZED PRELIM PRELIMINARY TS TUBE SECTION BTWN BETWEEN GB GRAB BAR PRESS PRESSURE TV TELEVISION C CHANNEL GB GRADE BEAM PRIM PRIMARY TYP TYPICAL CAB CABINET GC GENERAL CONTRACTOR PROJ PROJECTION UC UNDERCUT CANTL CANTILEVER GENR GENERATOR PRV POWER ROOF VENTILATOR UFD UNDER FLOOR DUCT CAT CATEGORY GEN GENERAL PNT PAINT UG UNDERGROUND CCTV CLOSED CIRCUIT TELEVISION GL GLASS PTR PRINTER UH UNIT HEATER CD COILING DOOR GMU GLASS MASONRY UNIT PVC POLYVINYL CHLORIDE UNFIN UNFINISHED CIS COILING GRILLE GR GRADE R RADIUS UNO UNLESS NOTED OTHERWISE CIS CORNER GUARD GWB GYPSUM WALLBOARD RA RETURN AIR UTIL UTILITY CH COAT HOOK H HEIGHT/HIGH RB RESILIENT BASE UTIL UTILITY CJT CONTROL JOINT HB HOSE BIB RD ROOF DRAIN VC VALVE CABINET CL CENTER LINE HD HAND DRYER RE RELOCATE EXISTING VENT VENTILATION CLG CEILING HDR HEADER PR PAIR VERT VERTICAL CLR CLEAR HDW HARDWARE PRELIM PRELIMINARY VEST VESTIBULE CM CONSTRUCTION MANAGER HM HOLLOW METAL PRESS PRESSURE VIF VERIFY IN FIELD CO CASED OPENING HORIZ HORIZONTAL PRIM PRIMARY VTR VENT THROUGH ROOF COL COLUMN HPT HIGH POINT PROJ PROJECTION W WIDTH/WIDE CONIC CONCRETE HR HANDRAIL PRV POWER ROOF VENTILATOR W WIDE FLANGE CONF CONFERENCE HT HEIGHT PNT PAINT W/ WITH CONN CONNECT/-ED/-ION HTR HEATER PTR PRINTER W/O WITHOUT CONST CONSTRUCTION HVAC HEATING, VENTILATING, AIR PVC POLYVINYL CHLORIDE WC WATER CLOSET CONT CONTINUE/OUS CONDITIONING R RADIUS WC WALL COVERING CONTR CONTRACT/OR HW HOT WATER RA RETURN AIR WD WOOD COORD COORDINATE IC INTERCOM RB RESILIENT BASE WDW WINDOW CORR CORRIDOR ID INSIDE DIAMETER RD ROOF DRAIN WG WALL GUARD CPT CARPET IN INCH RE RELOCATE EXISTING WH WALL HYDRANT CT CERAMIC TILE INSUL INSULATION REC RECESSED WHICH WHEELCHAIR CTR CENTER INT INTERIOR REF REFERENCE WHTR WATER HEATER CTSK COUNTERSUNK ISO ISOLATION REFR REFRIGERATOR WP WATERPROOF CW CURTAIN WALL JAN JANITOR REG REGISTER WR WASTE RECEPTACLE CYL CYLINDER JST JOIST REINF REINFORCE/-ED/-ING WS WEATHERSTRIP D DEPTH OR DEEP JT JOINT REM REMOVE WSCT WAINSCOT DEMO DEMOLITION KO KNOCK OUT READ REQUIRED WT WINDOW TREATMENT DPR DEPRESSION L ANGLE RET RETAINING WT WEIGHT DEPT DEPARTMENT LAV LAVATORY REV REVERSE WWF WELDED WIRE FABRIC DF DRINKING FOUNTAIN LB(S) POUND (S) REV REVISE DIA DIAMETER LCD LINEAR CEILING DIFFUSER RF RESILIENT FLOOR DIAG DIAGONAL LIN LINEAR RH ROOF HATCH DIFF DIFFUSER LKR LOCKER RM ROOM DIM DIMENSION LOC LOCATION OR LOCATE RO ROUGH OPENING DISP DISPENSER LPT LOW POINT IRS ROUGH SLAB DIST DISTRIBUTION LTG LIGHTING RWC RAIN WATER CONDUCTOR DIV DIVISION LVR LOUVER SCHED SCHEDULE DIN DOWN LWC LINEAR WOOD CEILING SD SHOWER DRAIN DP DEMOUNTABLE PARTITION M MIDDLE SD SMOKE DAMPER DR DOOR MAN MANUAL SDISP SOAP DISPENSER DS DOWNSPOUT MATL MATERIAL SF SQUARE FOOT (FEET) DWG DRAWING MAX MAXIMUM SH SHOWER (E) EXISTING MBD MARKER BOARD SHD SHOWER HEAD EA EACH MC MEDICINE CABINET SHT SHEET EC ELECTRIC CABINET MCU MODULAR COOLING UNIT SHTG SHEATHING EF EXHAUST FAN MECH MECHANICAL SIM SIMILAR EIFS EXTERIOR INSULATION AND MEMB MEMBRANE SL SEALER FINISH SYSTEM MEZZ MEZZANINE SLNT SEALANT EJT EXPANSION JOINT MFR MANUFACTURER SLV SLEEVE EL ELEVATION MH MANHOLE SM SURFACE MOUNTED ELEC ELECTRICAL MIN MINIMUM SNC SANITARY NAPKIN CABINET ELEV ELEVATOR MIR MIRROR SND SANITARY NAPKIN DISPOSER EMERG EMERGENCY MISC MISCELLANEOUS SOG SLAB ON GRADE ENCL ENCLOSURE MO MASONRY OPENING SP STANDPIPE ENTR ENTRANCE MONO MONOLITHIC SPC SPECIMEN PASS THROUGH EQ EQUAL MTL METAL CABINET EQUIP EQUIPMENT MPC METAL PAN CEILING SPEC SPECIFICATIONS ETR EXISTING TO REMAIN MTD MOUNTED SPR SINGLE PLY ROOF EXC EXCAVATE/-ED/-ION MULL MULLION SQ SQUARE EXH EXHAUST HOOD (N) NEW SQ YD SQUARE YARD EXP EXPANSION MTL METAL SR SIDEWALL REGISTER EXT EXTERIOR MPC METAL PAN CEILING SSTL STAINLESS STEEL FA FIRE ALARM MTD MOUNTED ST STREET BUILDING & LAND USE SUMMARY LAND USE DATA: ZONE: IRS 12 LOT AREA: (PER SNOHOMISH COUNTY RECORDS) 0.27 ACRES BUILDING AREAS: (PER SNOHOMISH COUNTY RECORDS) NO NEW FLOOR AREAS CREATE BY PROPOSED ALTERATIONS. NO CHANGE TO EXISTING QUANTITY OF FINISHED AND CONDITIONED AREAS. LEVEL B 688 SF FINISHED + 452 SF ATTACHED GARAGE PROPOSED ALTERATION AREA: 106 SF (FINISHED) LEVEL 01 1.026 SF FINISHED LEVEL 02 1,026 SF FINISHED ALL WORK TO BE COMPLETED IN COMPLIANCE WITH THE FOLLOWING CODES AND 1 - ARCHITECTURAL REGULATIONS AS AMENDED OR MODIFIED BY THE GOVERNING BODY, APPROVING AO.1 GENERAL INFORMATION AND INSPECTING THE PROJECT: A2.1 FLOOR PLANS B - 1 EDMONDS CITY CODE 2018 INTERNATIONAL FIRE CODE A2.2 FLOOR PLANS 2 - ROOF 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL MECHANICAL CODE A6.0 SCHEDULES AND ASSEMBLIES 2020 INTERNATIONAL ELECTRICAL CODE 2018 UNIFORM PLUMBING CODE 2018 WASHINGTON STATE ENERGY CODE 2018 INTERNATIONAL EXISTING BUILDING CODE ENERGY CODE COMPLIANCE SUMMARY PROJECT SCOPE INCLUDES LIMITED ALTERATIONS TO THE EXISTING BUILDING ENVELOPE AND SYSTEMS AT THE PROJECT WORK AREA ONLY. ALL NEW OR ALTERED ENVELOPE COMPONENTS TO COMPLY WITH APPLICABLE PRESCRIPTIVE PATH ENERGY CODE REQUIREMENTS PER C401.2.1. NO CHANGES ARE PROPOSED TO THE AMOUNT OF FINISHED AND CONDITIONED SPACE WITHIN THE BUILDING. LIGHTING IN THE WORK AREA WILL BE REPLACED AND/OR SUPPLEMENTED WITH HIGH -EFFICIENCY LED FIXTURES (>/= 65 LUMENS/WATT). r ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 01 II L I EPERATE PLUMBING REQUIURED FOR THIS PERMIT. ■ ■ I FB FIRE BLANKET MULL MULLION ST STONE TILE SECTION MATERIAL INDICATIONS SIM °" CONCRETE INSULATION (LOOSE OR BATT) EXISTING CONSTRUCTION A10.1 DETAIL PLAN/SECTION CALLOUT � DATUM POINT a 4 EARTH INSULATION (RIGID OR SPRAYED) EXISTING CONSTRUCTION � 12'-0" SPOT ELEVATION TO BE DEMOLISHED SAND GYPSUM WALL BOARD/PLASTER 1i WALL / ASSEMBLY O SMOKE/CO NEW CONSTRUCTION REFERENCE. DETECTOR BRICK/STONE CARPET EXIT SIGN (DIRECTION ARROW) OKEYNOTE REFERENCE FIRE EXTINGUISHER CABINET CONCRETE BLOCK ACOUSTIC TILE BUILDING SECTION 1 S I M RE. 906.3 OF FIRE CODE) REFERENCE ' A4.0 101a WINDOW TAG EF EXHAUST FAN STEEL/METAL WOOD (FRAMING) 1.1 101 DOOR TAG $T LIGHT SWITCH PLYWOOD WOOD (BLOCKING) tt DUPLEX OUTLET STRUCTURAL GRID ALIGN ALIGN WITH ESTABLISHED SURFACES (TGFI LIGHT SWITCH WOOD (FINISH) + CEILING HEIGHT ELECTRICAL PANEL/METER MATL. AND FINISH PROJECT INFORMATION ADDRESS: 819 DRIFTWOOD LANE EDMONDS, WASHINGTON 98020 OWNER: KRISTI GJYLAMETI PARCEL NUMBER: 27031300307500 LEGAL DESCRIPTION: SEC 13 TWP 27 RGE 03ALL TH PTN GOVT LOT 4 DAF - BEG S1/4 COR SEC TH N00*09 OOW ALG N-S C/L SD SEC 138.6FT TH N72*02 OOW 277.45 FT TH N00*09 OOW 199.91FT TO TPB TH CONTN09*09 OOW 130.09FT TO INT S LN OF PLATOF NORTHSTREAM LANE TH N72*02 OOW ALG SD S LN 138.73FT TH S00*09 OOE 30.25FT TH S38* 11 10E 181.53FT TH N89*51 OOE 20FT TO TPB AKA LOT 3 CITY ED SP5-42-79 AF NO 8003060184 PROJECT DESCRIPTION: INTERIOR ALTERATION TO CREATE ONE NEW FULL BATH & CLOSET AREA AT EXISTING FINISHED BASEMENT LEVEL BEDROOM. OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work REMODEL Address 819 DRIFTWOOD LANE -------------------------------------------- Owner GJYLAMETI ------------------------------- ------------------------------- Approved Date 5/26/2022 Building Official W. W C*UaIc Permit Number BLD2022-0626 VICINITY MAP Ln. 98020 M N dryftwoad�n z d z a' L z a r C, oy�wa oat„ Gjylameti Remodel OWNER Kristi Gjylameti 819 Driftwood Lane Edmonds, WA 98020 ARCH ITECT ImURBANAOO A R C H I T E C T S 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM MAY 1212022 PERMIT DRAWING SET 6447 ��;`'`IE E Y ele�Er�1I�� �a� 5obt�,�3 SYATE t�0I�;�1rli CONTRACTOR OWNER TO SERVE AS GENERAL CONTRACTOR PROJECT INFO PROJECT NUMBER: TBD INTAKE DATE: 2022.05.11 PERMIT STAMP ISSUE # ADD. REVISION DATE SHEET GENERAL INFORMATION RECEIVED May 13 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A08 1 F UTILITY LEVEL 00 1/4" = V-0" 1 2 3 4 5 (E) EGRESS WINDOW, TO REMAIN: (FIELD VERIFY DIMENSIONS AS REQUIRED) 2'- 6" MIN SILL HEIGHT MAX 44" AFF, NET CLEAR AREA 5.7 SF MIN, CLR 20" W, 24" H MIN. CLEAR En En GENERAL FLOOR PLAN NOTES -2'-6 VIF DIN C4t AREA OF WORK (106 SF) 7-7" X 14'-O" 1 j • EXHAUST VENTILATION OUTLET • o � (ABOVE) - SEE VENTILLATION NOTES • • EF QUARTZ PARTIAL HEIGSH HT FTOP SURFACE OF GHT FURRING WALL BEDROOM ' B4t 0 • TEMPERED GLASS ENCLOSURE 05 06 BAT 132t WALL @SHOWER • 06 -4'- 6" j FULL -HEIGHT PORCELAIN TILE I • VIF o FINISH AT SHOWER SURROUND _ • OFFICE A u 04 ��/- 4'-2- AFF FIELD VERIFY EXISTING VIF SMOKE/CO DETECTORS & o REPLACE OR SUPPLEMENT CLOSET AS NECESSARY TO MEET • 07 07 REQUIREMENTS. 0 0 i 6'-3" 12'-11 2" • -6'-6" v i S i VIF - _ -- -CLR-- -1-- ..... ELEVATOR HALL O MACHINE ELEVATOR 01 DIN ENTRY ROOM -4'- 6" 00 VIF 0' - 0 11 VIF `'0, �R- �,q O�� J�O 0 �° P GARAGEIF 1. ALL DIMENSIONS TO EXISTING WALLS, WINDOWS, DOORS, AND OTHER BUILDING ELEMENTS ARE TO BE CONSIDERED APPROXIMATE, AND ARE TO BE VERIFIED IN THE FIELD. 2. ALL WINDOWS AND DOORS THAT ARE EXISTING, TO BE REPLACED, ARE TO BE VERIFIED IN THE FIELD (MATCH HEIGHT, WIDTH, LOCATION, AND POSITION). CONTRACTOR TO VERIFY ANY DESCREPANCIES WITH ARCHITECT PRIOR TO ORDERING. 3. ALL PLAN DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS "CLEAR" (CLR) AND DIMENSIONS AT EXISTING FINISHED SURFACES TO REMAIN ARE TO FACES OF FINISHED MATERIALS. 4. NO ALTERATIONS TO GRADE, OR GROUND DISTURBANCE U.N.O. 5. WHERE NON-STRUCTURAL SLAB TRENCHING IS REQUIRED FOR PLUMBING DRAIN CONNECTIONS, REMOVE CONCRETE W/O SEVERING EXISTING REINFORCEMENT BAR & REPLACE SLAB ASSEMBLY AS FOLLOWS: 2,500 PSI CONCRETE OVER, 10 MIL POLYETHYLENE VAPOR BARRIER (OVERLAPPED AND SEALED TO EXISTING BARRIER) OVER, 4" CRUSHED STONE (NO FINES). MAIN ENTRY DOOR (AT GRADE LEVEL) n SMOKE/CO ALARM NOTES 1. SMOKE ALARMS SHALL BE LOCATED IN EACH SLEEPING ROOM, OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS, AND ON EACH ADDITIONAL STORY INCLUDING BASEMENTS AND HABITABLE ATTICS. 2. CO ALARMS SHALL BE INSTALLED OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS AND IN EACH SLEEPING ROOM WHERE A FUEL BURNING APPLIANCE IS LOCATED. 3. SMOKE AND CO DETECTORS SHALL BE PERMANENTLY WIRED TO THE BUILDING POWER SUPPLY WITH BATTERY BACKUP AND INTERCONNECTED ALARM SIGNALS (WIRED OR WIRELESS INTERCONNECTION PERMISSIBLE) 4. SMOKE ALARMS SHALL BE INSTALLED >/= T HORIZONTALLY FROM THE DOOR/OPENING OF A BATHROOM CONTAINING A TUB OR SHOWER; IONIZATION ALARMS SHALL BE INSTALLED >/= 20' HORIZONTALLY FROM PERMANENTLY INSTALLED COOKING APPLIANCES UNLESS EQUIPPED WITH AN ALARM SILENCING SWITCH, IN WHICH CASE THE DISTANCE IS >/= 10'; PHOTOELECTRIC ALARMS SHALL BE INSTALLED >/= 6' HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. Y) I (Y) I (4 Y LEVEL 01 1/4" = V-0" PLAN LEGEND NEW CONSTRUCTION EXISTING CONSTRUCTION TO REMAIN OS SMOKE/CO DETECTOR (ABOVE) - - - - - EF EXHAUST FAN & DUCT PATH (ABOVE) Gjylameti Remodel OWNER Kristi Gjylameti 819 Driftwood Lane Edmonds, WA 98020 ARCH ITECT ImURBANAOO A R C H I T E C T S 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM MAY 1212022 PERMIT DRAWING SET 6447I`i T CE A C ECT J"Ghi. BROWN STATE OF WASHINGTON CONTRACTOR OWNER TO SERVE AS GENERAL CONTRACTOR PROJECT INFO INTAKE DATE: 2022.05.11 PERMIT STAMP ISSUE # ADD. REVISION DATE SHEET FLOOR PLANS B - 1 RECEIVED May 13 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A2el 0' 2' 4' 8' 1 6' Gjylameti Remodel LEVEL 02 GENERAL FLOOR PLAN NOTES 1. ALL DIMENSIONS TO EXISTING WALLS, WINDOWS, DOORS, AND OTHER BUILDING ELEMENTS ARE TO BE CONSIDERED APPROXIMATE, AND ARE TO BE VERIFIED IN THE FIELD. 2. ALL WINDOWS AND DOORS THAT ARE EXISTING, TO BE REPLACED, ARE TO BE VERIFIED IN THE FIELD (MATCH HEIGHT, WIDTH, LOCATION, AND POSITION). CONTRACTOR TO VERIFY ANY DESCREPANCIES WITH ARCHITECT PRIOR TO ORDERING. 3. ALL PLAN DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED AS "CLEAR" (CLR) AND DIMENSIONS AT EXISTING FINISHED SURFACES TO REMAIN ARE TO FACES OF FINISHED MATERIALS. 4. NO ALTERATIONS TO GRADE, OR GROUND DISTURBANCE U.N.O. 5. WHERE NON-STRUCTURAL SLAB TRENCHING IS REQUIRED FOR PLUMBING DRAIN CONNECTIONS, REMOVE CONCRETE W/O SEVERING EXISTING REINFORCEMENT BAR & REPLACE SLAB ASSEMBLY AS FOLLOWS: 2,500 PSI CONCRETE OVER, 10 MIL POLYETHYLENE VAPOR BARRIER (OVERLAPPED AND SEALED TO EXISTING BARRIER) OVER, 4" CRUSHED STONE (NO FINES). SMOKE/CO ALARM NOTES 1. SMOKE ALARMS SHALL BE LOCATED IN EACH SLEEPING ROOM, OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS, AND ON EACH ADDITIONAL STORY INCLUDING BASEMENTS AND HABITABLE ATTICS. 2. CO ALARMS SHALL BE INSTALLED OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS AND IN EACH SLEEPING ROOM WHERE A FUEL BURNING APPLIANCE IS LOCATED. 3. SMOKE AND CO DETECTORS SHALL BE PERMANENTLY WIRED TO THE BUILDING POWER SUPPLY WITH BATTERY BACKUP AND INTERCONNECTED ALARM SIGNALS (WIRED OR WIRELESS INTERCONNECTION PERMISSIBLE) 4. SMOKE ALARMS SHALL BE INSTALLED >/= T HORIZONTALLY FROM THE DOOR/OPENING OF A BATHROOM CONTAINING A TUB OR SHOWER; IONIZATION ALARMS SHALL BE INSTALLED >/= 20' HORIZONTALLY FROM PERMANENTLY INSTALLED COOKING APPLIANCES UNLESS EQUIPPED WITH AN ALARM SILENCING SWITCH, IN WHICH CASE THE DISTANCE IS >/= 10'; PHOTOELECTRIC ALARMS SHALL BE INSTALLED >/= 6' HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. )T (Y) I (4 Y ROOF PLAN LEGEND NEW CONSTRUCTION EXISTING CONSTRUCTION TO REMAIN OS SMOKE/CO DETECTOR (ABOVE) - - - - - EF EXHAUST FAN & DUCT PATH (ABOVE) N (? OWNER Kristi Gjylameti 819 Driftwood Lane Edmonds, WA 98020 ARCH ITECT URBANAOO 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM MAY 1212022 PERMIT DRAWING SET 6447 FREGIS'TERED C�:7 ��� JAMES h1110 BROWN STATE OF WASHINGTON CONTRACTOR OWNER TO SERVE AS GENERAL CONTRACTOR PROJECT INFO PROJECT NUMBER: TBD INTAKE DATE: 2022.05.11 PERMIT STAMP ISSUE # ADD. REVISION DATE SHEET RECEIVED May 13 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A2e2 0' 2' 4' 8' 16' Gjylameti VENTILATION NOTES PER IRC M1501.1, THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS IN ACCORDANCE WITH SECTION M1504.3 - OPENINGS SHALL TERMINATE NOT LESS THAN 3 FEET FROM PROPERTY LINES; 3 FEET FROM OPERABLE AND NONOPERABLE OPENINGS INTO THE BUILDING AND 10 FEET FROM MECHANICAL AIR INTAKES EXCEPT WHERE THE OPENING IS LOCATED 3 FEET ABOVE THE AIR INTAKE. PER IRC M1505.4: M1505.4.1.2 - EXHAUST FANS SHALL BE DUCTED DIRECTLY OUTSIDE W/ OUTLETS DESIGNED TO LIMIT DIFFERENTIAL PRESSURE AND EQUIPPED WITH BACKDRAFT DAMPERS. BATH FANS DESIGNED FOR INTERMITTENT AIRFLOW HIGHER THAN THE CONTINUOUS RATES PER TABLE M1505.4.3(3) SHALL BE PROVIDED WITH OCCUPANCY OR HUMIDITY SENSORS TO AUTOMATICALLY OVERRIDE THE FAN TO THE HIGH SPEED AIRFLOW RATE. M1505.4 - LOCAL EXHAUST SHALL BE PROVIDED IN EACH KITCHEN, BATHROOM, WATER CLOSET AND SHALL HAVE THE EXHAUST CAPACITY DICTATED IN TABLE 1505.4.4 PER TABLE-M1505.4.4 LOCAL EXHAUST RATES: BATHROOMS, TOILET ROOMS: MECHANICAL EXHAUST CAPACITY OF 50 CFM INTERMITTENT EXHAUST RATE OR 20 CFM CONTINUOUS EXHAUST RATE AIRFLOW BETWEEN INLET AND EXHAUST OPENINGS TO BE FACILITATED BY DUCTS, GRILLES, AND/OR DOORS UNDERCUT BY 1/2" MINIMUM (ABOVE FINISHED FLOOR). WALL TYPES 1/2" GWB*, JOINTS STAGGERED 16" ON OPPOSITE SIDES, PAINT & FINISH PER SPEC. *CEMENTITIOUS TILE BACKER BOARD WITH FLUID APPLIED WATERPROOFING MEMBRANE AT WET LOCATIONS WHERE TILE FINISH IS SPECIFIED 2x FRAMING @ 16" O.C. 2x SILL PLATE BASE TRIM, AS SCHEDULED, TYP. �TUFRAMED WAL WALL TYPE NOTES 0 LU x LLI 1. STUD WALLS DESIGNATED AS "THERMAL" (INSULATED) TO BE FILLED W/ INSULATION CORRESPONDING W/ STUD DEPTH; 2x4: R-15, 2x6: R-21 (E) CONCRETE WALL, TO REMAIN WINDOW & DOOR NOTES 1. HAZARDOUS LOCATIONS - TEMPERED SAFETY GLASS (PER SRC TABLE R308.1) IS REQUIRED IN THE FOLLOWING LOCATIONS: • GLAZING ADJACENT TO DOORS @ < 60" ABOVE THE FLOOR OR WALKING SURFACE AND IN -PLANE WITHIN 24" OF EITHER SIDE OF THE DOOR IN A CLOSED POSITION OR PERPENDICULAR TO THE PLANE OF THE DOOR WITHIN 24" OF THE HINGE -SIDE OF AN IN -SWING DOOR • GLAZING IN INDIVIDUAL WINDOWS PANELS MEETING ALL OF THE FOLLOWING CRITERIA: A) EXPOSED AREA OF INDIVIDUAL PANE > 9 FT B) BOTTOM EDGE <18" AFF C) TOP EDGE > 36" AFF D) WALKING SURFACES WITHIN 36" (MEASURED HORIZONTALLY) • ALL GLAZING IN GUARDS OR RAILINGS • GLAZING IN WET LOCATIONS <60" AFF IN WALLS OR ENCLOSURES CONTAINING BATHTUBS, SHOWERS, SPAS, ETC. • GLAZING ADJACENT TO STAIR AND RAMPS WHERE BOTTOM EDGE IS <36" ABOVE THE WALKING SURFACE PLANE EXCEPT WHERE A 1-1/2" (MIN 0) RAIL CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 LBS/FT IS INSTALLED @ 34-36" AFF • GLAZING ADJACENT TO BOTTOM STAIR LANDINGS <36" ABOVE THE LANDING WITHIN A 60" HORIZONTAL ARC (< 180' FROM BOTTOM TREAD NOSING) EXCEPT WHERE GLAZING IS PROTECTED BY A GUARD (PER R312) AND IS >18" FROM THE GUARD 2. EMERGENCY ESCAPE AND RECUE OPENINGS SHALL MEET THE FOLLOWING CRITERIA: • NET CLEAR OPENING AREA OF >/= 5.7 FT WITH 20" WIDTH AND 24" HEIGHT CLEARANCE MINIMUM • SILL HEIGHT </= 44" AFF • WINDOW WELLS WITH HORIZONTAL AREA >/= 9 FTZ AND 36" WIDTH ALLOWING THE WINDOW TO BE FULLY OPENED ARE REQUIRED WHERE SILL HEIGHT IS BELOW GRADE. WHERE WELL DEPTH IS > 44" A PERMANENT LADDER OR STAIR IS REQUIRED. LADDER TO BE USABLE WITH WINDOW FULLY OPENED AND MAY NOT ENCROACH > 6" INTO THE CLEAR WINDOW WELL AREA - RUNGS @ 12" WIDTH, 18" O.C. WITH >/= 3" CLEARANCE AT MOUNTING WALL. 3. EGRESS DOORS TO MEET THE FOLLOWING CRITERIA: • SIDE -HINGED WITH 78" MINIMUM HEIGHT AND >/= 32" CLEAR WIDTH WITH THE DOOR OPEN 90' • 36" CLEAR LANDINGS @ EACH SIDE WITH </= 1/4" PER FOOT SLOPE • DOORS TO REMAIN OPENABLE FROM INSIDE THE DWELLING UNIT W/O THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 4. ALL NEW OR REPLACED WINDOWS AND DOORS IN EXTERIOR WALLS TO HAVE A MAXIMUM U-FACTOR OF 0.30 U.N.O. 5. ALL WINDOW AND DOOR HEADERS TO BE INSULATED WITH A MINIMUM R-10 INSULATION PER SREC TABLE 402.1.1 R-15 MIN. CONTINUOUS RIGID XPS OR TYPE IX EPS INSULATION, APPLIED AT (E) CONC. WALLS IN TWO OR MORE LAYERS W/ ALL SEAMS STAGGERED & EDGES SEALED USING A COMPATIBLE LOW -EXPANSION FOAM OR ADHESIVE 2x4 FURRING @ 16" O.C. 1/2" TYPE X GWB, PAINT & FINISH PER SPEC. -BASE TRIM, AS SCHEDULED, TYP. -2x PT SILL PLATE CAPILLARY BREAK (GASKET) & SEALANT AT (E) SLAB BASEMENT LEVEL FURRING WALL B NTS 2. WALLS DESIGNATED AS "FIRE" (RATED) TO BE 1-HOUR RATED ASSEMBLIES, MINIMUM 3. PROVIDE PLYWOOD SHEATHING (NOT SHOWN) AT FACE OF FRAMING (UNDER FINISHED SURFACE) AS REQUIRED BY STRUCTURAL DRAWINGS, TYP. 4. VERIFY ALL FRAMING AND CONNECTION REQUIREMENTS WITH STRUCTURAL DRAWINGS, TYP. 0 F x(E) CLADDING, FINISH PER SPEC. LU k:q] (E) WATER -RESISTIVE BARRIER (E) SHEATHING rMINERAL WOOL BATT INSULATION, FILL ENTIRE DEPTH OF EXISTING WALL CAVITY, WHERE EXPOSED (R-15 MIN @ 2X4, R-21 MIN @ 2X6) (E) 2x FRAMING @ 16" O.C. (N) 1/2" TYPE X GWB, PAINTED FINISH PER SPEC. (E) 2x SILL PLATE BASE TRIM, AS SCHEDULED - MATCH EXISTING U.N.O. PER TAG (E) EXTERIOR WALL W/ (N) INSULATION - WHERE EXPOSED NTS WALL TAG KEY A4t VARIATION CODE NOMINAL FRAMING DIMENSION (PLAN) WALL TYPE DESIGNATION VARIATION CODES: t THERMAL (INSULATED) f FIRE (RATED) WINDOW SCHEDULE �EGRES TEMPER NUMBER OPERATION WIDTH HEIGHT HEAD HEIGHT SILL HEIGHT S ED PHASE NOTES U-VALUE LEVEL 00 1 FIXED 2' - 6" 2' - 6" 6'- 10" 4'- 4" NO INO I New Construction 10.30 DOOR SCHEDULE MARK PHASE HEIGHT IWIDTH NOTE Interior LEVEL 00 06 New Construction 6- 8" 2' - 6" SOLID CORE WOOD, PAINT PER SPEC 07 New Construction 6- 8" 2' - 6" SOLID CORE WOOD, PAINT PER SPEC ENERGY CODE COMPLIANCE SUMMARY PROJECT SCOPE INCLUDES LIMITED ALTERATIONS TO THE EXISTING BUILDING ENVELOPE AND SYSTEMS AT THE PROJECT WORK AREA ONLY. ALL NEW OR ALTERED ENVELOPE COMPONENTS TO COMPLY WITH APPLICABLE PRESCRIPTIVE PATH ENERGY CODE REQUIREMENTS PER C401.2.1. NO CHANGES ARE PROPOSED TO THE AMOUNT OF FINISHED AND CONDITIONED SPACE WITHIN THE BUILDING. ALL EXISTING HEATING & COOLING SYSTEMS ARE TO REMAIN, WITHOUT ALTERATION. LIGHTING IN THE WORK AREA WILL BE REPLACED AND/OR SUPPLEMENTED WITH HIGH -EFFICIENCY LED FIXTURES (>/= 65 LUMENS/WATT). PER WSEC R501.1.1: ADDITIONS, ALTERATIONS, OR REPAIRS TO AN EXISTING BUILDING, BUILDING SYSTEM OR PORTION THEREOF SHALL COMPLY WITH SECTIONS R502 (ADDITIONS), R503 (ALTERATIONS), OR R504 (REPAIRS). UNALTERED PORTIONS OF THE EXISTING BUILDING OR BUILDING SUPPLY SYSTEM SHALL NOT BE REQUIRED TO COMPLY WITH THIS CODE. PER 503.1.1. EXCEPTION: THE FOLLOWING ALTERATIONS NEED NOT COMPLY WITH THE REQUIREMENTS FOR NEW CONSTRUCTION PROVIDED THE ENERGY USE OF THE BUILDING IS NOT INCREASED: 2. EXISTING CEILING, WALL, OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION PROVIDED THAT THESE CAVITIES ARE FILLED WITH INSULATION. 2X4 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OF R-15 AND 2X6 WALLS SHALL BE INSULATED TO A MINIMUM OF R21. 3. CONSTRUCTION WHERE THE EXISTING ROOF, WALL, OR FLOOR CAVITY IS NOT EXPOSED. PRESCRIPTIVE ENVELOPE COMPONENT VALUES PER WSEC TABLE R402.1.1 U-FACTOR (TYP.) = 0.3 MAX. U-FACTOR (SKYLIGHT) = 0.5 MAX. CEILING INSULATION = R-49 MIN. EXT. WALL INS. = R-21 MIN. FLOOR = R-30 MIN. BELOW GRADE WALL = R-10/R-15./R-21+TB (EXISTING) R-15 USED SLAB = R-10, 2FT BELOW GRADE (EXISTING) NO NEW INSULATION INSULATION CERTIFICATE FOR RESIDENTIAL CONSTRUCTION: (WSEC R401.3) BUILDER TO PROVIDE A PERMANENT CERTIFICATE, COMPLETED AND POSTED ON OR WITHIN 3 FEET OF THE ELECTRICAL DISTRIBUTION PANEL PER WSEC R401.3 PRIOR TO FINAL INSPECTION. (APPLIES TO NEW INSULATION ONLY) Remodel OWNER Kristi Gjylameti 819 Driftwood Lane Edmonds, WA 98020 ARCH ITECT mIURBANAOO A R C H I T E C T S 1936 FIRST AVENUE SOUTH SEATTLE, WA 98134 P 206 274 8020 CONTACT: ANDREW LAWRENCE ALAWRENCE@URBANADD.COM MAY 1212022 PERMIT DRAWING SET 6447 JAMES IPA, � BROWN CONTRACTOR OWNER TO SERVE AS GENERAL CONTRACTOR PROJECT INFO PROJECT NUMBER: TBD INTAKE DATE: 2022.05.11 PERMIT STAMP ISSUE # ADD. REVISION DATE RECEIVED May 13 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT A6eO