APPROVED BLD BLD2022-0626+Architectural_Plan+5.12.2022_1.32.45_PM+2866370PROJECT NOTES
TYPICAL ABBREVIATIONS
PROJECT CODE SUMMARY DRAWING INDEX
1. WORK OF THE CONTRACT INCLUDES THE
14. CONTRACTOR SHALL MAINTAIN SITE IN A STATE OF
FURNISHING OF ALL MATERIALS, LABOR, EQUIPMENT,
CLEANLINESS THROUGHOUT THE DURATION OF THE
TOOLS, TRANSPORTATION, INSURANCE, SALES TAXES,
PROJECT.
PERMITS, LICENSES, SUPERINTENDENT AND
MISCELLANEOUS SERVICES REQUIRED FOR THE
15. PAVED SURFACES INCLUDING ROADWAYS,
CONSTRUCTION AND COMPLETION OF THE PROJECT AS
SIDEWALKS, AND CURBS THAT ARE DAMAGED BY NEW
REQUIRED BY THE PLANS AND SPECIFICATIONS.
CONSTRUCTION SHALL BE REPAIRED AS REQUIRED BY
THE STREET USE INSPECTOR.
2. ALL WORK SHALL CONFORM TO THE CONTRACT
DOCUMENTS WHICH INCLUDE THE DRAWINGS, ALL
16. ALL LOCATIONS OF EXISTING UTILITIES SHOWN
ADDENDUMS AND MODIFICATIONS ISSUED BY THE
HEREIN HAVE BEEN ESTABLISHED BY A FIELD SURVEY
ARCHITECT.
OBTAINED FROM AVAILABLE RECORDS AND SHOULD BE
CONSIDERED APPROXIMATE ONLY AND NOT
3. ALL WORK DONE UNDER THIS CONTRACT SHALL
NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY
CONFORM TO ALL APPLICABLE CODES, ORDINANCES
OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE
AND GOVERNMENT REGULATIONS HAVING
ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO
JURISDICTION OVER THE WORK.
FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES
NOT SHOWN HEREIN WHICH MAY BE AFFECTED BY THE
IMPLEMENTATION OF THIS PLAN.
4. ANY SPECIFIC REFERENCE TO CODES, RULES,
REGULATIONS, STANDARDS, MANUFACTURER'S
17. THE CONTRACTOR SHALL LOCATE AND PROTECT ALL
INSTRUCTIONS OR REQUIREMENTS OF REGULATORY
CASTINGS AND UTILITIES DURING CONSTRUCTION AND
SHALL MEAN THE LATEST PRINTED EDITION OF EACH IS
SHALL CONTACT THE UNDERGROUND UTILITIES LOCATOR
IN EFFECT AT THE DATE OF SUBMISSION OR BID UNLESS
SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO
THE DOCUMENT IS SHOWN DATED.
CONSTRUCTION.
5. A COPY OF THE APPROVED PLAN MUST BE ON SITE
18. UTILITY SERVICE CONNECTIONS SHOWN ARE TO BE
WHENEVER CONSTRUCTION IS IN PROGRESS.
MAINTAINED PRIVATELY AND NOT BY THE CITY OF
SEATTLE.
6. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS
CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THE
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN
STREETS WILL NOT BE ALLOWED WITHOUT PRIOR
TEMPORARY SEDIMENTATION COLLECTION FACILITIES TO
APPROVAL.
INSURE THAT WATER DOESN'T ENTER THE NATURAL OR
PUBLIC DRAINAGE SYSTEM. AS CONSTRUCTION
7. INTERPRETATIONS -THESE DOCUMENTS ARE IN
PROGRESSES AND UNEXPECTED (SEASONAL)
PART DIAGRAMMATIC AND SUBJECT TO
CONDITIONS DICTATE, MORE SILTATION CONTROL
INTERPRETATION. THEY DO NOT NECESSARILY SHOW
FACILITIES MAY BE REQUIRED TO INSURE COMPLETE
COMPLETE DETAILS OF CONSTRUCTION, WORK OR
SILTATION CONTROL OF THE PROJECT. THEREFORE,
MATERIALS, OR INSTALLATION, AND DO NOT
DURING THE COURSE OF CONSTRUCTION IT SHALL BE
NECESSARILY SHOW HOW CONSTRUCTION DETAILS OF
THE OBLIGATION AND RESPONSIBILITY OF THE
OTHER WORK MAY AFFECT ANY PARTICULAR
CONTRACTOR TO ADDRESS ANY NEW CONDITIONS THAT
INSTALLATION.
MAY BE CREATED BY HIS/HER ACTIVITY AND TO PROVIDE
ADDITIONAL FACILITIES THAT MAY BE NEEDED TO
8. DIMENSIONS -THE DRAWINGS MAY NOT BE DRAWN
PROTECT ADJACENT PROPERTIES. SEE THE DRAINAGE
TO SCALE IN SOME INSTANCES; FOLLOW DIMENSIONS
CONTROL PLAN FOR MORE INFORMATION.
BUT DO NOT SCALE THE DRAWINGS: WHERE
DIMENSIONS ARE NOTED "CONFIRM" OR "VERIFY",
20. ALL WORK PERFORMED BY PUBLIC UTILITY ENTITIES
CONSULT THE ARCHITECT FOR DIMENSION CRITERIA
TO REMOVE OR RELOCATE EXISTING UTILITIES SHALL BE
BEFORE PROCEEDING WITH THE WORK. ALL DIMENSIONS
DONE AT THE PERMITEE'S EXPENSE.
ARE GIVEN TO THE FACE OF FINISH MATERIALS, UNLESS
OTHERWISE NOTED.
21. A SIGNED AFFIDAVIT DOCUMENTING ANY REQUIRED
COMMISSIONING SHALL BE PROVIDED TO THE BUILDING
9. THE GENERAL CONTRACTOR (GC) SHALL REVIEW ALL
INSPECTOR PRIOR TO AN APPROVED FINAL INSPECTION.
DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD
CONDITIONS AND SHALL CONFIRM THAT WORK IS
22. UPON SUBSTANTIAL COMPLETION, THE
BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSIONS,
CONTRACTOR SHALL PROVIDE FINAL CLEANING FOR
ETC., SHALL BE IMMEDIATELY REPORTED TO THE
EACH AREA WHICH WILL RESULT IN A LEVEL OF
ARCHITECT FOR CLARIFICATION PRIOR TO THE
CLEANLINESS CLEANING SHALL INCLUDE, BUT IS NOT
PERFORMANCE OF ANY WORK IN QUESTION. THE GC
LIMITED TO: GLASS, CARPET, PLASTIC LAMINATE, LIGHT
SHALL ARRANGE FOR INSPECTIONS NECESSARY TO
FIXTURES AND REMOVAL OF LABELS (NOT REQUIRED TO
OBTAIN A CERTIFICATE OF OCCUPANCY.
BE PERMANENT BY CODE). CONTRACTOR SHALL
SCHEDULE FINAL CLEANING SO OWNER MAY OCCUPY
10. IN CASE OF CONFLICT BETWEEN ARCHITECTS AND
COMPLETELY CLEAN PROJECT.
CONSULTANTS DRAWINGS IN LOCATING
MATERIALS/EQUIPMENT, THE ARCHITECT SHALL BE
23. ALL MATERIALS AND EQUIPMENT SHALL BE
NOTIFIED FOR CLARIFICATION.
INSTALLED IN STRICT ACCORDANCE WITH
MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE
11. SUBSTITUTIONS, REVISIONS, OR CHANGES MUST BE
ASSOCIATES ACCEPTED STANDARDS.
SUBMITTED TO ARCHITECT FOR REVIEW (IN
CONFORMANCE WITH SPECIFIED PROCEDURES) PRIOR
24. CONTRACTOR SHALL PROVIDE A WRITTEN
TO PURCHASE, FABRICATION, OR INSTALLATION. IT IS
CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL
THE RESPONSIBILITY OF THE GC TO COORDINATE
INCLUDE DELIVERY TIMES OF CONSTRUCTION ITEMS,
ORDERS, SUBMITTALS AND IMPLEMENTATION OF LONG
AND START AND COMPLETION DATES OF EACH PHASE.
LEAD ITEMS. SUBSTITUTIONS WILL NOT BE CONSIDERED
THE CONTRACTOR SHALL UPDATE AND PROVIDE THIS
RESULTING FROM THE GC'S FAILURE TO MAKE LONG
SCHEDULE ON A BI-WEEKLY BASIS.
LEAD ITEM ORDERS IN A TIMELY FASHION. WHERE
DELAYS MAY OCCUR DUE TO AN ITEM NOT BEING
25. GENERAL CONTRACTOR IS RESPONSIBLE FOR
ORDERED IN A TIMELY FASHION, GENERAL CONTRACTOR
PROVIDING ALL NECCESSARY BACKING, BLOCKING, AND
SHALL PROVIDE, AT HIS COST, A TEMPORARY
FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES,
REPLACEMENT AND THEN CHANGE OUT TO THE
CASEWORK, PLUMBING FIXTURES, GRAB BARS AND ALL
SPECIFIED ITEM UPON ARRIVAL/DELIVERY.
OTHER ITEMS REQUIRING IT.
12. ALL MANUFACTURED ARTICLES, MATERIALS AND
26. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED
EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED,
ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS
ERECTED, CLEANED, AND CONDITIONED PER MFR.'S
IF DRAWN IN FULL.
INSTRUCTIONS. IN CASE OF DIFFERENCES BETWEEN THE
MANUFACTURER'S INSTRUCTIONS AND CONTRACT
27. ANY AND ALL DESCREPANCIES FOUND BETWEEN
DOCUMENTS, THE GC SHALL NOTIFY THE ARCHITECT
FIELD CONDITIONS AND DRAWINGS OR WITHIN THE
BEFORE PROCEEDING.
DRAWING SET ARE TO BE BROUGHT TO ARCHITECTS
ATTENTION IMMEDIATELY, PRIOR TO CONTINUING
13. ALL MATERIALS DELIVERED TO THE JOB SITE SHALL
WORK.
BE PROPERLY STORED WITHIN THE PREMISES OR AT A
LOCATION DESIGNATED BY BUILDING OWNER. DELIVERY,
HANDLING AND STORAGE OF PRODUCTS SHALL BE IN A
MANNER TO PREVENT DAMAGE, DETERIORATION, LOSS
OR THEFT.
SYMBOL LEGEND
N
NORTH ARROW
z
CD REVISION CLOUD
Room name
123 ROOM TAG
1
1 A101 1 EXTERIOR ELEVATION
REFERENCE
1
1
1 A1.0 1 INTERIOR ELEVATION
REFERENCE
1
&
AND
FBR
FACE BRICK
(N)
NEW
@
AT
FD
FLOOR DRAIN
NA
NOT APPLICABLE
STC
SOUND TRANSMISSION
#
POUND/ NUMBER
FDN
FOUNDATION
NIC
NOT IN CONTRACT
COEFFICIENT
ABV
ABOVE
FDV
FIRE DEPARTMENT VALVE
NO
NUMBER
STD
STANDARD
ACOUS
ACOUSTICAL
FE
FIRE EXTINGUISHER
NOM
NOMINAL
STL
STEEL
ACT
ACOUSTICAL CEILING TILE
FGS
FOAM GASKET SEAL
NRC
NOISE REDUCTION COEFFICIENT
STN
STONE
ADD
ADDENDUM
FH
FIRE HOSE
NT
NOTE
STOR
STORAGE
ADDL
ADDITIONAL
FHC
FIRE HOSE CABINET
NTS
NOT TO SCALE
STRUCT STRUCTURAL
ADJ
ADJUSTABLE/ADJACENT
FHV
FIRE HOSE VALVE
OC
ON CENTER
STS
STEEL STRUCTURE
ADMIN
ADMINISTRATION
FIN
FINISH
OD
OUTSIDE DIAMETER
SW
STEEL WINDOWS
AFF
ABOVE FINISH FLOOR
FIXT
FIXTURE
OFCI
OWNER FURNISHED -
SW
SWITCH
AHU
AIR HANDLING UNIT
FL
FLOOR
CONTRACTOR INSTALLED
SWD
SOFTWOOD
ALT
ALTERNATE
FLASH
FLASHING
OFF
OFFICE
SYM
SYMMETRICAL
ALUM
ALUMINUM
FLEX
FLEXIBLE
OH
OVERHEAD
T
TOP
ANUN
ANUNCIATOR
FLG
FLANGE
OP
OPERABLE PARTITION
TAN
TANGENT
AP
ACCESS PANEL
FLUOR
FLUORESCENT
OPNG
OPENING
TBD
TACKBOARD
APROX
APPROXIMATE
FOIC
FURNISHED BY OWNER-
OPP
OPPOSITE
TC
TIME CLOCK
ARCH
ARCHITECTURAL/ ARCHITECT
INSTALLED BY CONTRACTOR
ORD
OVERFLOW ROOF DRAIN
TCAB
TOWEL CABINET
BD
BOARD
FP
FIRE PROOFING
PART
PARTITION
TDISP
TISSUE DISPENSER
BFE
BOTTOM FOOTING ELEVATION
FRMG
FRAMING
PC
PRECAST CONCRETE
TDR
TRENCH DRAIN
BG
BUMPER GUARD
FS
FLOOR SINK
PED
PEDESTAL
TEL
TELEPHONE
BLDG
BUILDING
FSTOP
FIRESTOPPING
PL
PROPERTY LINE
TEMP
TEMPERATURE
BLKG
BLOCKING
FT
FOOT/FEET
PLAM
PLASTIC LAMINATE
TER
TERRAllO
BLW
BELOW
FTG
FOOTING
PLBG
PLUMBING
T&G
TONGUE & GROOVE
BM
BEAM
FURR
FURRING
PLS
PLASTER
THRES
THRESHOLD
BO
BOTTOM OF
FUT
FUTURE
PLW
PLYWOOD
TPH
TOILET PAPER HOLDER
BOT
BOTTOM
GA
GAUGE
PNL
PANEL
TR
TREAD
BR
BRICK
GAL
GALLONS
PR
PAIR
TRANSF TRANSFORMER
BSMT
BASEMENT
GALV
GALVANIZED
PRELIM
PRELIMINARY
TS
TUBE SECTION
BTWN
BETWEEN
GB
GRAB BAR
PRESS
PRESSURE
TV
TELEVISION
C
CHANNEL
GB
GRADE BEAM
PRIM
PRIMARY
TYP
TYPICAL
CAB
CABINET
GC
GENERAL CONTRACTOR
PROJ
PROJECTION
UC
UNDERCUT
CANTL
CANTILEVER
GENR
GENERATOR
PRV
POWER ROOF VENTILATOR
UFD
UNDER FLOOR DUCT
CAT
CATEGORY
GEN
GENERAL
PNT
PAINT
UG
UNDERGROUND
CCTV
CLOSED CIRCUIT TELEVISION
GL
GLASS
PTR
PRINTER
UH
UNIT HEATER
CD
COILING DOOR
GMU
GLASS MASONRY UNIT
PVC
POLYVINYL CHLORIDE
UNFIN
UNFINISHED
CIS
COILING GRILLE
GR
GRADE
R
RADIUS
UNO
UNLESS NOTED OTHERWISE
CIS
CORNER GUARD
GWB
GYPSUM WALLBOARD
RA
RETURN AIR
UTIL
UTILITY
CH
COAT HOOK
H
HEIGHT/HIGH
RB
RESILIENT BASE
UTIL
UTILITY
CJT
CONTROL JOINT
HB
HOSE BIB
RD
ROOF DRAIN
VC
VALVE CABINET
CL
CENTER LINE
HD
HAND DRYER
RE
RELOCATE EXISTING
VENT
VENTILATION
CLG
CEILING
HDR
HEADER
PR
PAIR
VERT
VERTICAL
CLR
CLEAR
HDW
HARDWARE
PRELIM
PRELIMINARY
VEST
VESTIBULE
CM
CONSTRUCTION MANAGER
HM
HOLLOW METAL
PRESS
PRESSURE
VIF
VERIFY IN FIELD
CO
CASED OPENING
HORIZ
HORIZONTAL
PRIM
PRIMARY
VTR
VENT THROUGH ROOF
COL
COLUMN
HPT
HIGH POINT
PROJ
PROJECTION
W
WIDTH/WIDE
CONIC
CONCRETE
HR
HANDRAIL
PRV
POWER ROOF VENTILATOR
W
WIDE FLANGE
CONF
CONFERENCE
HT
HEIGHT
PNT
PAINT
W/
WITH
CONN
CONNECT/-ED/-ION
HTR
HEATER
PTR
PRINTER
W/O
WITHOUT
CONST
CONSTRUCTION
HVAC
HEATING, VENTILATING, AIR
PVC
POLYVINYL CHLORIDE
WC
WATER CLOSET
CONT
CONTINUE/OUS
CONDITIONING
R
RADIUS
WC
WALL COVERING
CONTR
CONTRACT/OR
HW
HOT WATER
RA
RETURN AIR
WD
WOOD
COORD
COORDINATE
IC
INTERCOM
RB
RESILIENT BASE
WDW
WINDOW
CORR
CORRIDOR
ID
INSIDE DIAMETER
RD
ROOF DRAIN
WG
WALL GUARD
CPT
CARPET
IN
INCH
RE
RELOCATE EXISTING
WH
WALL HYDRANT
CT
CERAMIC TILE
INSUL
INSULATION
REC
RECESSED
WHICH
WHEELCHAIR
CTR
CENTER
INT
INTERIOR
REF
REFERENCE
WHTR
WATER HEATER
CTSK
COUNTERSUNK
ISO
ISOLATION
REFR
REFRIGERATOR
WP
WATERPROOF
CW
CURTAIN WALL
JAN
JANITOR
REG
REGISTER
WR
WASTE RECEPTACLE
CYL
CYLINDER
JST
JOIST
REINF
REINFORCE/-ED/-ING
WS
WEATHERSTRIP
D
DEPTH OR DEEP
JT
JOINT
REM
REMOVE
WSCT
WAINSCOT
DEMO
DEMOLITION
KO
KNOCK OUT
READ
REQUIRED
WT
WINDOW TREATMENT
DPR
DEPRESSION
L
ANGLE
RET
RETAINING
WT
WEIGHT
DEPT
DEPARTMENT
LAV
LAVATORY
REV
REVERSE
WWF
WELDED WIRE FABRIC
DF
DRINKING FOUNTAIN
LB(S)
POUND (S)
REV
REVISE
DIA
DIAMETER
LCD
LINEAR CEILING DIFFUSER
RF
RESILIENT FLOOR
DIAG
DIAGONAL
LIN
LINEAR
RH
ROOF HATCH
DIFF
DIFFUSER
LKR
LOCKER
RM
ROOM
DIM
DIMENSION
LOC
LOCATION OR LOCATE
RO
ROUGH OPENING
DISP
DISPENSER
LPT
LOW POINT
IRS
ROUGH SLAB
DIST
DISTRIBUTION
LTG
LIGHTING
RWC
RAIN WATER CONDUCTOR
DIV
DIVISION
LVR
LOUVER
SCHED
SCHEDULE
DIN
DOWN
LWC
LINEAR WOOD CEILING
SD
SHOWER DRAIN
DP
DEMOUNTABLE PARTITION
M
MIDDLE
SD
SMOKE DAMPER
DR
DOOR
MAN
MANUAL
SDISP
SOAP DISPENSER
DS
DOWNSPOUT
MATL
MATERIAL
SF
SQUARE FOOT (FEET)
DWG
DRAWING
MAX
MAXIMUM
SH
SHOWER
(E)
EXISTING
MBD
MARKER BOARD
SHD
SHOWER HEAD
EA
EACH
MC
MEDICINE CABINET
SHT
SHEET
EC
ELECTRIC CABINET
MCU
MODULAR COOLING UNIT
SHTG
SHEATHING
EF
EXHAUST FAN
MECH
MECHANICAL
SIM
SIMILAR
EIFS
EXTERIOR INSULATION AND
MEMB
MEMBRANE
SL
SEALER
FINISH SYSTEM
MEZZ
MEZZANINE
SLNT
SEALANT
EJT
EXPANSION JOINT
MFR
MANUFACTURER
SLV
SLEEVE
EL
ELEVATION
MH
MANHOLE
SM
SURFACE MOUNTED
ELEC
ELECTRICAL
MIN
MINIMUM
SNC
SANITARY NAPKIN CABINET
ELEV
ELEVATOR
MIR
MIRROR
SND
SANITARY NAPKIN DISPOSER
EMERG
EMERGENCY
MISC
MISCELLANEOUS
SOG
SLAB ON GRADE
ENCL
ENCLOSURE
MO
MASONRY OPENING
SP
STANDPIPE
ENTR
ENTRANCE
MONO
MONOLITHIC
SPC
SPECIMEN PASS THROUGH
EQ
EQUAL
MTL
METAL
CABINET
EQUIP
EQUIPMENT
MPC
METAL PAN CEILING
SPEC
SPECIFICATIONS
ETR
EXISTING TO REMAIN
MTD
MOUNTED
SPR
SINGLE PLY ROOF
EXC
EXCAVATE/-ED/-ION
MULL
MULLION
SQ
SQUARE
EXH
EXHAUST HOOD
(N)
NEW
SQ YD
SQUARE YARD
EXP
EXPANSION
MTL
METAL
SR
SIDEWALL REGISTER
EXT
EXTERIOR
MPC
METAL PAN CEILING
SSTL
STAINLESS STEEL
FA
FIRE ALARM
MTD
MOUNTED
ST
STREET
BUILDING & LAND USE SUMMARY
LAND USE DATA:
ZONE:
IRS 12
LOT AREA: (PER SNOHOMISH COUNTY RECORDS)
0.27 ACRES
BUILDING AREAS: (PER SNOHOMISH COUNTY RECORDS)
NO NEW FLOOR AREAS CREATE BY PROPOSED
ALTERATIONS. NO CHANGE TO EXISTING QUANTITY OF
FINISHED AND CONDITIONED AREAS.
LEVEL B
688 SF FINISHED + 452 SF ATTACHED GARAGE
PROPOSED ALTERATION AREA: 106 SF (FINISHED)
LEVEL 01
1.026 SF FINISHED
LEVEL 02
1,026 SF FINISHED
ALL WORK TO BE COMPLETED IN COMPLIANCE WITH THE FOLLOWING CODES AND 1 - ARCHITECTURAL
REGULATIONS AS AMENDED OR MODIFIED BY THE GOVERNING BODY, APPROVING AO.1 GENERAL INFORMATION
AND INSPECTING THE PROJECT: A2.1 FLOOR PLANS B - 1
EDMONDS CITY CODE 2018 INTERNATIONAL FIRE CODE A2.2 FLOOR PLANS 2 - ROOF
2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL MECHANICAL CODE A6.0 SCHEDULES AND ASSEMBLIES
2020 INTERNATIONAL ELECTRICAL CODE 2018 UNIFORM PLUMBING CODE
2018 WASHINGTON STATE ENERGY CODE 2018 INTERNATIONAL EXISTING BUILDING CODE
ENERGY CODE COMPLIANCE SUMMARY
PROJECT SCOPE INCLUDES LIMITED ALTERATIONS TO THE EXISTING BUILDING
ENVELOPE AND SYSTEMS AT THE PROJECT WORK AREA ONLY. ALL NEW OR
ALTERED ENVELOPE COMPONENTS TO COMPLY WITH APPLICABLE PRESCRIPTIVE
PATH ENERGY CODE REQUIREMENTS PER C401.2.1.
NO CHANGES ARE PROPOSED TO THE AMOUNT OF FINISHED AND CONDITIONED
SPACE WITHIN THE BUILDING.
LIGHTING IN THE WORK AREA WILL BE REPLACED AND/OR SUPPLEMENTED WITH
HIGH -EFFICIENCY LED FIXTURES (>/= 65 LUMENS/WATT).
r ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 01
II
L
I
EPERATE PLUMBING REQUIURED FOR THIS
PERMIT.
■
■ I
FB FIRE BLANKET MULL
MULLION
ST STONE TILE
SECTION MATERIAL INDICATIONS
SIM
°"
CONCRETE
INSULATION (LOOSE OR BATT)
EXISTING CONSTRUCTION
A10.1
DETAIL PLAN/SECTION
CALLOUT
�
DATUM POINT
a 4
EARTH
INSULATION (RIGID OR SPRAYED)
EXISTING CONSTRUCTION
� 12'-0"
SPOT ELEVATION
TO BE DEMOLISHED
SAND
GYPSUM WALL BOARD/PLASTER
1i
WALL / ASSEMBLY
O
SMOKE/CO
NEW CONSTRUCTION
REFERENCE.
DETECTOR
BRICK/STONE
CARPET
EXIT SIGN (DIRECTION ARROW)
OKEYNOTE
REFERENCE
FIRE EXTINGUISHER CABINET
CONCRETE BLOCK
ACOUSTIC TILE
BUILDING SECTION
1 S I M
RE. 906.3 OF FIRE CODE)
REFERENCE
' A4.0
101a
WINDOW TAG
EF
EXHAUST FAN
STEEL/METAL
WOOD (FRAMING)
1.1
101
DOOR TAG
$T
LIGHT SWITCH
PLYWOOD
WOOD (BLOCKING)
tt
DUPLEX OUTLET
STRUCTURAL GRID
ALIGN
ALIGN WITH ESTABLISHED
SURFACES
(TGFI
LIGHT SWITCH
WOOD (FINISH)
+
CEILING HEIGHT
ELECTRICAL
PANEL/METER
MATL.
AND FINISH
PROJECT INFORMATION
ADDRESS:
819 DRIFTWOOD LANE
EDMONDS, WASHINGTON 98020
OWNER:
KRISTI GJYLAMETI
PARCEL NUMBER:
27031300307500
LEGAL DESCRIPTION:
SEC 13 TWP 27 RGE 03ALL TH PTN GOVT LOT
4 DAF - BEG S1/4 COR SEC TH N00*09 OOW
ALG N-S C/L SD SEC 138.6FT TH N72*02 OOW
277.45 FT TH N00*09 OOW 199.91FT TO TPB
TH CONTN09*09 OOW 130.09FT TO INT S LN
OF PLATOF NORTHSTREAM LANE TH N72*02
OOW ALG SD S LN 138.73FT TH S00*09 OOE
30.25FT TH S38* 11 10E 181.53FT TH N89*51
OOE 20FT TO TPB AKA LOT 3 CITY ED
SP5-42-79 AF NO 8003060184
PROJECT DESCRIPTION:
INTERIOR ALTERATION TO CREATE ONE NEW
FULL BATH & CLOSET AREA AT EXISTING
FINISHED BASEMENT LEVEL BEDROOM.
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
APPROVED
PLANS MUST BE
ON JOB SITE
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
City Of Edmonds
Building Department
Work REMODEL
Address 819 DRIFTWOOD LANE
--------------------------------------------
Owner GJYLAMETI
-------------------------------
-------------------------------
Approved Date 5/26/2022
Building Official W. W C*UaIc
Permit Number BLD2022-0626
VICINITY MAP
Ln.
98020
M
N dryftwoad�n
z
d
z
a'
L
z
a
r
C,
oy�wa
oat„
Gjylameti
Remodel
OWNER
Kristi Gjylameti
819 Driftwood Lane
Edmonds, WA 98020
ARCH ITECT
ImURBANAOO
A R C H I T E C T S
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
MAY 1212022
PERMIT DRAWING SET
6447
��;`'`IE
E
Y
ele�Er�1I�� �a� 5obt�,�3
SYATE t�0I�;�1rli
CONTRACTOR
OWNER TO SERVE AS GENERAL CONTRACTOR
PROJECT INFO
PROJECT NUMBER: TBD
INTAKE DATE: 2022.05.11
PERMIT STAMP
ISSUE
# ADD. REVISION DATE
SHEET
GENERAL INFORMATION
RECEIVED
May 13 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
A08 1
F
UTILITY
LEVEL 00
1/4" = V-0"
1 2 3 4 5
(E) EGRESS WINDOW, TO REMAIN:
(FIELD VERIFY DIMENSIONS AS REQUIRED) 2'- 6" MIN
SILL HEIGHT MAX 44" AFF,
NET CLEAR AREA 5.7 SF MIN, CLR
20" W, 24" H MIN. CLEAR En En
GENERAL FLOOR PLAN NOTES
-2'-6
VIF
DIN
C4t AREA OF WORK
(106 SF) 7-7" X 14'-O"
1
j • EXHAUST VENTILATION OUTLET
• o � (ABOVE) - SEE VENTILLATION NOTES
•
•
EF QUARTZ PARTIAL HEIGSH HT FTOP SURFACE OF
GHT FURRING WALL
BEDROOM ' B4t
0 •
TEMPERED GLASS ENCLOSURE
05 06 BAT 132t WALL @SHOWER
• 06
-4'- 6" j FULL -HEIGHT PORCELAIN TILE
I • VIF o FINISH AT SHOWER SURROUND
_
•
OFFICE A
u
04 ��/- 4'-2-
AFF
FIELD VERIFY EXISTING VIF
SMOKE/CO DETECTORS &
o REPLACE OR SUPPLEMENT CLOSET
AS NECESSARY TO MEET •
07 07
REQUIREMENTS. 0 0
i
6'-3" 12'-11 2" • -6'-6" v
i S i VIF - _ -- -CLR-- -1--
.....
ELEVATOR HALL O
MACHINE ELEVATOR 01 DIN ENTRY
ROOM -4'- 6" 00
VIF 0' - 0
11
VIF
`'0,
�R-
�,q
O�� J�O
0
�°
P
GARAGEIF
1. ALL DIMENSIONS TO EXISTING WALLS, WINDOWS, DOORS, AND OTHER BUILDING ELEMENTS ARE TO BE CONSIDERED APPROXIMATE,
AND ARE TO BE VERIFIED IN THE FIELD.
2. ALL WINDOWS AND DOORS THAT ARE EXISTING, TO BE REPLACED, ARE TO BE VERIFIED IN THE FIELD (MATCH HEIGHT, WIDTH,
LOCATION, AND POSITION). CONTRACTOR TO VERIFY ANY DESCREPANCIES WITH ARCHITECT PRIOR TO ORDERING.
3. ALL PLAN DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED
AS "CLEAR" (CLR) AND DIMENSIONS AT EXISTING FINISHED SURFACES TO REMAIN ARE TO FACES OF FINISHED MATERIALS.
4. NO ALTERATIONS TO GRADE, OR GROUND DISTURBANCE U.N.O.
5. WHERE NON-STRUCTURAL SLAB TRENCHING IS REQUIRED FOR PLUMBING DRAIN CONNECTIONS, REMOVE CONCRETE W/O SEVERING
EXISTING REINFORCEMENT BAR & REPLACE SLAB ASSEMBLY AS FOLLOWS: 2,500 PSI CONCRETE OVER, 10 MIL POLYETHYLENE VAPOR
BARRIER (OVERLAPPED AND SEALED TO EXISTING BARRIER) OVER, 4" CRUSHED STONE (NO FINES).
MAIN ENTRY DOOR
(AT GRADE LEVEL)
n
SMOKE/CO ALARM NOTES
1. SMOKE ALARMS SHALL BE LOCATED IN EACH SLEEPING ROOM, OUTSIDE EACH
SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS, AND ON EACH
ADDITIONAL STORY INCLUDING BASEMENTS AND HABITABLE ATTICS.
2. CO ALARMS SHALL BE INSTALLED OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE
VICINITY OF BEDROOMS AND IN EACH SLEEPING ROOM WHERE A FUEL BURNING
APPLIANCE IS LOCATED.
3. SMOKE AND CO DETECTORS SHALL BE PERMANENTLY WIRED TO THE BUILDING
POWER SUPPLY WITH BATTERY BACKUP AND INTERCONNECTED ALARM SIGNALS
(WIRED OR WIRELESS INTERCONNECTION PERMISSIBLE)
4. SMOKE ALARMS SHALL BE INSTALLED >/= T HORIZONTALLY FROM THE
DOOR/OPENING OF A BATHROOM CONTAINING A TUB OR SHOWER; IONIZATION
ALARMS SHALL BE INSTALLED >/= 20' HORIZONTALLY FROM PERMANENTLY INSTALLED
COOKING APPLIANCES UNLESS EQUIPPED WITH AN ALARM SILENCING SWITCH, IN
WHICH CASE THE DISTANCE IS >/= 10'; PHOTOELECTRIC ALARMS SHALL BE
INSTALLED >/= 6' HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING
APPLIANCE.
Y) I (Y) I (4 Y
LEVEL 01
1/4" = V-0"
PLAN LEGEND
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
OS SMOKE/CO DETECTOR (ABOVE)
- - - - - EF EXHAUST FAN & DUCT PATH (ABOVE)
Gjylameti
Remodel
OWNER
Kristi Gjylameti
819 Driftwood Lane
Edmonds, WA 98020
ARCH ITECT
ImURBANAOO
A R C H I T E C T S
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
MAY 1212022
PERMIT DRAWING SET
6447I`i T CE
A C ECT
J"Ghi. BROWN
STATE OF WASHINGTON
CONTRACTOR
OWNER TO SERVE AS GENERAL CONTRACTOR
PROJECT INFO
INTAKE DATE: 2022.05.11
PERMIT STAMP
ISSUE
# ADD. REVISION DATE
SHEET
FLOOR PLANS B - 1
RECEIVED
May 13 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
A2el
0' 2' 4' 8' 1 6'
Gjylameti
Remodel
LEVEL 02
GENERAL FLOOR PLAN NOTES
1. ALL DIMENSIONS TO EXISTING WALLS, WINDOWS, DOORS, AND OTHER BUILDING ELEMENTS ARE TO BE CONSIDERED APPROXIMATE,
AND ARE TO BE VERIFIED IN THE FIELD.
2. ALL WINDOWS AND DOORS THAT ARE EXISTING, TO BE REPLACED, ARE TO BE VERIFIED IN THE FIELD (MATCH HEIGHT, WIDTH,
LOCATION, AND POSITION). CONTRACTOR TO VERIFY ANY DESCREPANCIES WITH ARCHITECT PRIOR TO ORDERING.
3. ALL PLAN DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATED
AS "CLEAR" (CLR) AND DIMENSIONS AT EXISTING FINISHED SURFACES TO REMAIN ARE TO FACES OF FINISHED MATERIALS.
4. NO ALTERATIONS TO GRADE, OR GROUND DISTURBANCE U.N.O.
5. WHERE NON-STRUCTURAL SLAB TRENCHING IS REQUIRED FOR PLUMBING DRAIN CONNECTIONS, REMOVE CONCRETE W/O SEVERING
EXISTING REINFORCEMENT BAR & REPLACE SLAB ASSEMBLY AS FOLLOWS: 2,500 PSI CONCRETE OVER, 10 MIL POLYETHYLENE VAPOR
BARRIER (OVERLAPPED AND SEALED TO EXISTING BARRIER) OVER, 4" CRUSHED STONE (NO FINES).
SMOKE/CO ALARM NOTES
1. SMOKE ALARMS SHALL BE LOCATED IN EACH SLEEPING ROOM, OUTSIDE EACH
SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS, AND ON EACH
ADDITIONAL STORY INCLUDING BASEMENTS AND HABITABLE ATTICS.
2. CO ALARMS SHALL BE INSTALLED OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE
VICINITY OF BEDROOMS AND IN EACH SLEEPING ROOM WHERE A FUEL BURNING
APPLIANCE IS LOCATED.
3. SMOKE AND CO DETECTORS SHALL BE PERMANENTLY WIRED TO THE BUILDING
POWER SUPPLY WITH BATTERY BACKUP AND INTERCONNECTED ALARM SIGNALS
(WIRED OR WIRELESS INTERCONNECTION PERMISSIBLE)
4. SMOKE ALARMS SHALL BE INSTALLED >/= T HORIZONTALLY FROM THE
DOOR/OPENING OF A BATHROOM CONTAINING A TUB OR SHOWER; IONIZATION
ALARMS SHALL BE INSTALLED >/= 20' HORIZONTALLY FROM PERMANENTLY INSTALLED
COOKING APPLIANCES UNLESS EQUIPPED WITH AN ALARM SILENCING SWITCH, IN
WHICH CASE THE DISTANCE IS >/= 10'; PHOTOELECTRIC ALARMS SHALL BE
INSTALLED >/= 6' HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING
APPLIANCE.
)T (Y) I (4 Y
ROOF
PLAN LEGEND
NEW CONSTRUCTION
EXISTING CONSTRUCTION TO REMAIN
OS SMOKE/CO DETECTOR (ABOVE)
- - - - - EF EXHAUST FAN & DUCT PATH (ABOVE)
N
(?
OWNER
Kristi Gjylameti
819 Driftwood Lane
Edmonds, WA 98020
ARCH ITECT
URBANAOO
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
MAY 1212022
PERMIT DRAWING SET
6447
FREGIS'TERED
C�:7
���
JAMES h1110 BROWN
STATE OF WASHINGTON
CONTRACTOR
OWNER TO SERVE AS GENERAL CONTRACTOR
PROJECT INFO
PROJECT NUMBER: TBD
INTAKE DATE: 2022.05.11
PERMIT STAMP
ISSUE
# ADD. REVISION DATE
SHEET
RECEIVED
May 13 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
A2e2
0' 2' 4' 8' 16'
Gjylameti
VENTILATION NOTES
PER IRC M1501.1, THE AIR REMOVED BY EVERY MECHANICAL EXHAUST SYSTEM SHALL BE DISCHARGED TO THE OUTDOORS IN
ACCORDANCE WITH SECTION M1504.3 - OPENINGS SHALL TERMINATE NOT LESS THAN 3 FEET FROM PROPERTY LINES; 3 FEET FROM
OPERABLE AND NONOPERABLE OPENINGS INTO THE BUILDING AND 10 FEET FROM MECHANICAL AIR INTAKES EXCEPT WHERE THE
OPENING IS LOCATED 3 FEET ABOVE THE AIR INTAKE.
PER IRC M1505.4:
M1505.4.1.2 - EXHAUST FANS SHALL BE DUCTED DIRECTLY OUTSIDE W/ OUTLETS DESIGNED TO LIMIT DIFFERENTIAL PRESSURE AND
EQUIPPED WITH BACKDRAFT DAMPERS. BATH FANS DESIGNED FOR INTERMITTENT AIRFLOW HIGHER THAN THE CONTINUOUS RATES
PER TABLE M1505.4.3(3) SHALL BE PROVIDED WITH OCCUPANCY OR HUMIDITY SENSORS TO AUTOMATICALLY OVERRIDE THE FAN TO
THE HIGH SPEED AIRFLOW RATE.
M1505.4 - LOCAL EXHAUST SHALL BE PROVIDED IN EACH KITCHEN, BATHROOM, WATER CLOSET AND SHALL HAVE THE EXHAUST
CAPACITY DICTATED IN TABLE 1505.4.4
PER TABLE-M1505.4.4 LOCAL EXHAUST RATES:
BATHROOMS, TOILET ROOMS: MECHANICAL EXHAUST CAPACITY OF 50 CFM INTERMITTENT EXHAUST RATE OR 20 CFM
CONTINUOUS EXHAUST RATE
AIRFLOW BETWEEN INLET AND EXHAUST OPENINGS TO BE FACILITATED BY DUCTS, GRILLES, AND/OR DOORS UNDERCUT BY 1/2"
MINIMUM (ABOVE FINISHED FLOOR).
WALL TYPES
1/2" GWB*, JOINTS STAGGERED
16" ON OPPOSITE SIDES, PAINT &
FINISH PER SPEC.
*CEMENTITIOUS TILE BACKER
BOARD WITH FLUID APPLIED
WATERPROOFING MEMBRANE
AT WET LOCATIONS WHERE TILE
FINISH IS SPECIFIED
2x FRAMING @ 16" O.C.
2x SILL PLATE
BASE TRIM, AS SCHEDULED, TYP.
�TUFRAMED WAL
WALL TYPE NOTES
0
LU
x
LLI
1. STUD WALLS DESIGNATED AS "THERMAL" (INSULATED) TO BE FILLED W/
INSULATION CORRESPONDING W/ STUD DEPTH; 2x4: R-15, 2x6: R-21
(E) CONCRETE WALL, TO REMAIN
WINDOW & DOOR NOTES
1. HAZARDOUS LOCATIONS - TEMPERED SAFETY GLASS (PER SRC TABLE R308.1) IS REQUIRED IN THE FOLLOWING LOCATIONS:
• GLAZING ADJACENT TO DOORS @ < 60" ABOVE THE FLOOR OR WALKING SURFACE AND IN -PLANE WITHIN 24" OF EITHER SIDE OF THE DOOR IN
A CLOSED POSITION OR PERPENDICULAR TO THE PLANE OF THE DOOR WITHIN 24" OF THE HINGE -SIDE OF AN IN -SWING DOOR
• GLAZING IN INDIVIDUAL WINDOWS PANELS MEETING ALL OF THE FOLLOWING CRITERIA:
A) EXPOSED AREA OF INDIVIDUAL PANE > 9 FT
B) BOTTOM EDGE <18" AFF
C) TOP EDGE > 36" AFF
D) WALKING SURFACES WITHIN 36" (MEASURED HORIZONTALLY)
• ALL GLAZING IN GUARDS OR RAILINGS
• GLAZING IN WET LOCATIONS <60" AFF IN WALLS OR ENCLOSURES CONTAINING BATHTUBS, SHOWERS, SPAS, ETC.
• GLAZING ADJACENT TO STAIR AND RAMPS WHERE BOTTOM EDGE IS <36" ABOVE THE WALKING SURFACE PLANE EXCEPT WHERE A 1-1/2" (MIN
0) RAIL CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 LBS/FT IS INSTALLED @ 34-36" AFF
• GLAZING ADJACENT TO BOTTOM STAIR LANDINGS <36" ABOVE THE LANDING WITHIN A 60" HORIZONTAL ARC (< 180' FROM BOTTOM TREAD
NOSING) EXCEPT WHERE GLAZING IS PROTECTED BY A GUARD (PER R312) AND IS >18" FROM THE GUARD
2. EMERGENCY ESCAPE AND RECUE OPENINGS SHALL MEET THE FOLLOWING CRITERIA:
• NET CLEAR OPENING AREA OF >/= 5.7 FT WITH 20" WIDTH AND 24" HEIGHT CLEARANCE MINIMUM
• SILL HEIGHT </= 44" AFF
• WINDOW WELLS WITH HORIZONTAL AREA >/= 9 FTZ AND 36" WIDTH ALLOWING THE WINDOW TO BE FULLY OPENED ARE REQUIRED WHERE
SILL HEIGHT IS BELOW GRADE. WHERE WELL DEPTH IS > 44" A PERMANENT LADDER OR STAIR IS REQUIRED. LADDER TO BE USABLE WITH
WINDOW FULLY OPENED AND MAY NOT ENCROACH > 6" INTO THE CLEAR WINDOW WELL AREA - RUNGS @ 12" WIDTH, 18" O.C. WITH >/= 3"
CLEARANCE AT MOUNTING WALL.
3. EGRESS DOORS TO MEET THE FOLLOWING CRITERIA:
• SIDE -HINGED WITH 78" MINIMUM HEIGHT AND >/= 32" CLEAR WIDTH WITH THE DOOR OPEN 90'
• 36" CLEAR LANDINGS @ EACH SIDE WITH </= 1/4" PER FOOT SLOPE
• DOORS TO REMAIN OPENABLE FROM INSIDE THE DWELLING UNIT W/O THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.
4. ALL NEW OR REPLACED WINDOWS AND DOORS IN EXTERIOR WALLS TO HAVE A MAXIMUM U-FACTOR OF 0.30 U.N.O.
5. ALL WINDOW AND DOOR HEADERS TO BE INSULATED WITH A MINIMUM R-10 INSULATION PER SREC TABLE 402.1.1
R-15 MIN. CONTINUOUS RIGID XPS OR
TYPE IX EPS INSULATION, APPLIED AT
(E) CONC. WALLS IN TWO OR MORE
LAYERS W/ ALL SEAMS STAGGERED &
EDGES SEALED USING A COMPATIBLE
LOW -EXPANSION FOAM OR ADHESIVE
2x4 FURRING @ 16" O.C.
1/2" TYPE X GWB, PAINT &
FINISH PER SPEC.
-BASE TRIM, AS SCHEDULED, TYP.
-2x PT SILL PLATE
CAPILLARY BREAK (GASKET) & SEALANT
AT (E) SLAB
BASEMENT LEVEL FURRING WALL
B
NTS
2. WALLS DESIGNATED AS "FIRE" (RATED) TO BE 1-HOUR RATED ASSEMBLIES,
MINIMUM
3. PROVIDE PLYWOOD SHEATHING (NOT SHOWN) AT FACE OF FRAMING (UNDER
FINISHED SURFACE) AS REQUIRED BY STRUCTURAL DRAWINGS, TYP.
4. VERIFY ALL FRAMING AND CONNECTION REQUIREMENTS WITH STRUCTURAL
DRAWINGS, TYP.
0
F
x(E) CLADDING, FINISH PER SPEC.
LU k:q]
(E) WATER -RESISTIVE BARRIER
(E) SHEATHING
rMINERAL WOOL BATT INSULATION, FILL ENTIRE
DEPTH OF EXISTING WALL CAVITY, WHERE EXPOSED
(R-15 MIN @ 2X4, R-21 MIN @ 2X6)
(E) 2x FRAMING @ 16" O.C.
(N) 1/2" TYPE X GWB, PAINTED FINISH PER SPEC.
(E) 2x SILL PLATE
BASE TRIM, AS SCHEDULED -
MATCH EXISTING U.N.O.
PER TAG
(E) EXTERIOR WALL W/ (N) INSULATION - WHERE EXPOSED
NTS
WALL TAG KEY
A4t
VARIATION CODE
NOMINAL FRAMING DIMENSION (PLAN)
WALL TYPE DESIGNATION
VARIATION CODES:
t THERMAL (INSULATED)
f FIRE (RATED)
WINDOW SCHEDULE
�EGRES TEMPER
NUMBER OPERATION WIDTH HEIGHT HEAD HEIGHT SILL HEIGHT S ED PHASE NOTES U-VALUE
LEVEL 00
1 FIXED 2' - 6" 2' - 6" 6'- 10" 4'- 4" NO INO I New Construction 10.30
DOOR SCHEDULE
MARK PHASE HEIGHT IWIDTH NOTE
Interior
LEVEL 00
06 New Construction 6- 8" 2' - 6" SOLID CORE WOOD, PAINT PER SPEC
07 New Construction 6- 8" 2' - 6" SOLID CORE WOOD, PAINT PER SPEC
ENERGY CODE COMPLIANCE SUMMARY
PROJECT SCOPE INCLUDES LIMITED ALTERATIONS TO THE EXISTING BUILDING
ENVELOPE AND SYSTEMS AT THE PROJECT WORK AREA ONLY. ALL NEW OR
ALTERED ENVELOPE COMPONENTS TO COMPLY WITH APPLICABLE PRESCRIPTIVE
PATH ENERGY CODE REQUIREMENTS PER C401.2.1.
NO CHANGES ARE PROPOSED TO THE AMOUNT OF FINISHED AND
CONDITIONED SPACE WITHIN THE BUILDING. ALL EXISTING HEATING &
COOLING SYSTEMS ARE TO REMAIN, WITHOUT ALTERATION.
LIGHTING IN THE WORK AREA WILL BE REPLACED AND/OR SUPPLEMENTED WITH
HIGH -EFFICIENCY LED FIXTURES (>/= 65 LUMENS/WATT).
PER WSEC R501.1.1:
ADDITIONS, ALTERATIONS, OR REPAIRS TO AN EXISTING BUILDING, BUILDING SYSTEM
OR PORTION THEREOF SHALL COMPLY WITH SECTIONS R502 (ADDITIONS), R503
(ALTERATIONS), OR R504 (REPAIRS). UNALTERED PORTIONS OF THE EXISTING BUILDING
OR BUILDING SUPPLY SYSTEM SHALL NOT BE REQUIRED TO COMPLY WITH THIS CODE.
PER 503.1.1. EXCEPTION: THE FOLLOWING ALTERATIONS NEED NOT COMPLY WITH THE
REQUIREMENTS FOR NEW CONSTRUCTION PROVIDED THE ENERGY USE OF THE
BUILDING IS NOT INCREASED:
2. EXISTING CEILING, WALL, OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION
PROVIDED THAT THESE CAVITIES ARE FILLED WITH INSULATION. 2X4 FRAMED WALLS
SHALL BE INSULATED TO A MINIMUM OF R-15 AND 2X6 WALLS SHALL BE INSULATED TO A
MINIMUM OF R21.
3. CONSTRUCTION WHERE THE EXISTING ROOF, WALL, OR FLOOR CAVITY IS NOT
EXPOSED.
PRESCRIPTIVE ENVELOPE COMPONENT VALUES PER WSEC TABLE R402.1.1
U-FACTOR (TYP.)
= 0.3 MAX.
U-FACTOR (SKYLIGHT)
= 0.5 MAX.
CEILING INSULATION
= R-49 MIN.
EXT. WALL INS.
= R-21 MIN.
FLOOR
= R-30 MIN.
BELOW GRADE WALL
= R-10/R-15./R-21+TB (EXISTING) R-15 USED
SLAB
= R-10, 2FT BELOW GRADE (EXISTING) NO NEW INSULATION
INSULATION CERTIFICATE FOR RESIDENTIAL CONSTRUCTION: (WSEC R401.3)
BUILDER TO PROVIDE A PERMANENT CERTIFICATE, COMPLETED AND POSTED ON
OR WITHIN 3 FEET OF THE ELECTRICAL DISTRIBUTION PANEL PER WSEC R401.3
PRIOR TO FINAL INSPECTION. (APPLIES TO NEW INSULATION ONLY)
Remodel
OWNER
Kristi Gjylameti
819 Driftwood Lane
Edmonds, WA 98020
ARCH ITECT
mIURBANAOO
A R C H I T E C T S
1936 FIRST AVENUE SOUTH
SEATTLE, WA 98134
P 206 274 8020
CONTACT: ANDREW LAWRENCE
ALAWRENCE@URBANADD.COM
MAY 1212022
PERMIT DRAWING SET
6447
JAMES IPA,
� BROWN
CONTRACTOR
OWNER TO SERVE AS GENERAL CONTRACTOR
PROJECT INFO
PROJECT NUMBER: TBD
INTAKE DATE: 2022.05.11
PERMIT STAMP
ISSUE
# ADD. REVISION DATE
RECEIVED
May 13 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
A6eO