APPROVED BLD BLD2020-0994+Structural_Plans+10.15.2020_11.51.19_AMSTRUCTURAL NOTES GENERAL REQUIREMENTS BUILDING CODE & REFERENCE STANDARDS: THE "INTERNATIONAL BUILDING CODE" (IBC), 2015 EDITION, AS ADOPTED AND MODIFIED BY THE CITY OF EDMONDS, GOVERNS THE DESIGN AND CONSTRUCTION OF THIS PROJECT. REFERENCE TO A SPECIFIC SECTION IN THE CODE DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE MATERIALS REFERENCE STANDARDS NOTED BELOW. THE LATEST EDITION OF THE MATERIALS REFERENCE STANDARDS SHALL BE USED. SCOPE OF STRUCTURAL WORK: STRUCTURAL DESIGN OF SINGLE FAMILY REMODEL. DEFINITIONS: THE FOLLOWING DEFINITIONS APPLY TO THESE GENERAL NOTES: • "ENGINEER OF RECORD" (EOR) - THE ENGINEER WHO IS LEGALLY RESPONSIBLE FOR STAMPING & SIGNING THE STRUCTURAL DOCUMENTS FOR THE PROJECT. THE FOR IS RESPONSIBLE FOR THE DESIGN OF THE PRIMARY STRUCTURAL SYSTEM. NOTE PRIORITIES: NOTES ON THE INDIVIDUAL DRAWINGS SHALL GOVERN OVER THESE GENERAL NOTES. STRUCTURAL DETAILS: THE STRUCTURAL DRAWINGS ARE INTENDED TO SHOW THE GENERAL CHARACTER AND EXTENT OF THE PROJECT AND ARE NOT INTENDED TO SHOW ALL DETAILS OF THE WORK. ARCHITECTURAL DRAWINGS: REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION INCLUDING, BUT NOT LIMITED TO: DIMENSIONS, ELEVATIONS, SLOPES, DOOR AND WINDOW OPENINGS, NON -BEARING WALLS, STAIRS, CURBS, DRAINS, DEPRESSIONS, RAILINGS, WATERPROOFING, FINISHES AND OTHER NONSTRUCTURAL ITEMS. STRUCTURAL RESPONSIBILITIES: THE FOR IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE PRIMARY STRUCTURE IN ITS COMPLETED STATE. CONTRACTOR RESPONSIBILITIES: THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA AND WSHA. THE CONTRACTOR IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE STRUCTURE DURING CONSTRUCTION AND SHALL PROVIDE TEMPORARY SHORING, BRACING AND OTHER ELEMENTS REQUIRED TO MAINTAIN STABILITY UNTIL THE STRUCTURE IS COMPLETED. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BE FAMILIAR WITH THE WORK REQUIRED IN THE CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS FOR EXECUTING IT PROPERLY. DISCREPANCIES: IN CASE OF DISCREPANCIES BETWEEN THESE GENERAL NOTES, THE CONTRACT DRAWINGS AND SPECIFICATIONS, AND/OR REFERENCE STANDARDS, THE FOR SHALL DETERMINE WHICH SHALL GOVERN. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE FOR BEFORE PROCEEDING WITH THE WORK. ACCORDINGLY, ANY CONFLICT IN OR BETWEEN THE CONTRACT DOCUMENTS SHALL NOT BE A BASIS FOR ADJUSTMENT IN THE CONTRACT PRICE. SITE VERIFICATION: THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO FABRICATION AND/OR CONSTRUCTION. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE FOR BEFORE PROCEEDING WITH THE WORK. ALL UNDERGROUND UTILITIES SHALL BE DETERMINED BY THE CONTRACTOR PRIOR TO EXCAVATION OR DRILLING. ADJACENT UTILITIES: THE CONTRACTOR SHALL DETERMINE THE LOCATIONS OF ALL ADJACENT UNDERGROUND UTILITIES PRIOR TO EXCAVATION OR PILE PLACEMENT. ANY UTILITY INFORMATION SHOWN ON THE DRAWINGS AND DETAILS IS APPROXIMATE AND NOT NECESSARILY COMPLETE. DESIGN CRITERIA CONSTRUCTION LOADS: LOADS ON THE STRUCTURE DURING CONSTRUCTION SHALL NOT EXCEED THE DESIGN LOADS OR THE CAPACITY OF THE PARTIALLY COMPLETED CONSTRUCTION. SNOW LOAD:THE ROOF SNOW LOAD IS DETERMINE BY USING CHAPTER 7 OF ASCE 7-10 IN ACCORDANCE WITH IBC SECTION 1608 AND WITH THE FOLLOWING FACTORS: MINIMUM ROOF DESIGN LOAD 25 PSF WITHOUT DRIFT GROUND SNOW LOAD, PG = 25 PSF IMPORTANCE FACTOR, IS = 1.0 THERMAL FACTOR, CT = 1.0 LIVE LOADS: ROOF (LIVE) 20 PSF ROOF (SNOW) SEE ABOVE FLOOR LIVE 40 PSF WIND DESIGN: WIND LOAD IS DETERMINED USING CHAPTER 27 OF ASCE 7-10 IN ACCORDANCE WITH IBC CHAPTER 16 09WITH THE FOLLOWING FACTORS: BASIC WIND SPEED (3-SECOND GUST) V = 110 MPH WIND IMPORTANCE FACTOR Iw = 1.0 RISK CATEGORY = II EXPOSURE CATEGORY = B SEISMIC DESIGN: EARTHQUAKE DESIGN IS DETERMINED USING CHAPTER 12 OF ASCE 7-10 IN ACCORDANCE WITH IBC CHAPTER 16 WITH THE FOLLOWING FACTORS: IMPORTANCE FACTOR le = 1.0 RISK CATEGORY = II Ss = 1.290g Sds = 0.860g S1 = 0.506g Sd 1 = 0.506g SITE CLASS = D SEISMIC DESIGN CATEGORY = D DEFLECTIONS: ROOF TOTAL LOAD DEFLECTION LIMIT: L/240 ROOF LIVE LOAD DEFLECTION LIMIT: L/360 FLOOR TOTAL LOAD DEFLECTION LIMIT: L/240 FLOOR LIVE LOAD DEFLECTION LIMIT: L/360 TESTS & INSPECTIONS INSPECTIONS: ALL CONSTRUCTION IS SUBJECT TO INSPECTION BY THE BUILDING OFFICIAL IN ACCORDANCE WITH IBC SEC 110. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED INSPECTIONS WITH THE BUILDING OFFICIAL. SUBMIT COPIES OF ALL INSPECTION REPORTS TO THE ARCHITECT/EOR FOR REVIEW. THE BUILDING OFFICIAL MAY ACCEPT INSPECTION OF AND REPORTS BY APPROVED INSPECTION AGENCIES IN LIEU OF BUILDING OFFICIAL'S INSPECTIONS. THE CONTRACTOR SHALL OBTAIN APPROVAL OF BUILDING OFFICIAL TO USE THE THIRD -PARTY INSPECTION AGENCY AND CONTRACTOR SHALL ALERT THE ARCHITECT/EOR AS SUCH. WOOD FRAMING REFERENCE STANDARDS: CONFORM TO: (1)IBC CHAPTER 23 "WOOD." (2)NDS AND NDS SUPPLEMENT - "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION." (3)ANSI/TPI 1 "NATIONAL DESIGN STANDARD FOR METAL -PLATE -CONNECTED WOOD TRUSS CONSTRUCTION." (4)BCSI 2013 "BUILDING COMPONENT SAFETY INFORMATION." ALTERNATES: ALTERNATES FOR SPECIFIED ITEM MAY BE SUBMITTED TO THE FOR FOR REVIEW. CONTRACTOR SHALL SUBMIT A CURRENT ICC-ESR/IAPMO-ER REPORT IDENTIFYING THAT AN ALTERNATIVE COMPONENT HAS THE SAME OR GREATER LOAD CAPACITY THAN THE SPECIFIED ITEM. IDENTIFICATION: ALL SAWN LUMBER AND PRE -MANUFACTURED WOOD PRODUCTS SHALL BE IDENTIFIED BY THE GRADE MARK OR A CERTIFICATE OF MATERIALS: SAWN LUMBER: CONFORM TO GRADING RULES OF WWPA, WCLIB, OR NLGA. FINGER JOINTED STUDS ACCEPTABLE AT INTERIOR NON-STRUCTURAL WALLS ONLY. MEMBER USE SIZE SPECIES GRADE STUDS & PLATES 2X4, 2X6 HF NO. 2 POSTS 4X4 HF NO. 2 BEAMS & HEADERS 4X8 -- 4X12 HF NO. 2 WOOD STRUCTURAL SHEATHING (PLYWOOD): WOOD APA-RATED STRUCTURAL SHEATHING INCLUDES: ALL VENEER PLYWOOD, ORIENTED STRAND BOARD, WAFERBOARD, PARTICLEBOARD, T1-11 SIDING, AND COMPOSITES OF VENEER AND WOOD BASED MATERIAL. CONFORM TO PRODUCT STANDARDS PS-1-95 AND PS-2-92 OF THE U.S. DEPT. OF COMMERCE AND THE AMERICAN PLYWOOD ASSOCIATION (APA) MINIMUM APA RATING LOCATION THICKNESS SPAN RATING PLYWOOD GRADE EXPOSURE ROOF 15/32" 24/16 C-D 1 FLOOR 23/32" T&G24 OC STURD-I-FLOOR 1 WALLS 15/32" 32/16 C-D 1 JOIST HANGERS AND CONNECTORS: SIMPSON STRONG -TIE COMPANY INC. AS SPECIFIED IN THEIR LATEST CATALOGS WAS USED AS THE BASIS OF DESIGN FOR THIS PROJECT. ALTERNATE CONNECTORS BY OTHER MANUFACTURERS MAY BE SUBSTITUTED PROVIDED THEY HAVE CURRENT ICC-ESR/IAPMO-ER APPROVAL FOR EQUIVALENT OR GREATER LOAD CAPACITIES AND ARE REVIEWED AND APPROVED BY THE FOR PRIOR TO ORDERING. CONNECTORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE 1/2 OF THE NAILS OR BOLTS IN EACH MEMBER. NAIL STRAPS TO WOOD FRAMING AS LATE AS POSSIBLE IN THE FRAMING PROCESS TO ALLOW THE WOOD TO SHRINK AND THE BUILDING TO SETTLE. NAILS AND STAPLES: CONFORM TO IBC SEC 2303.6 "NAILS AND STAPLES." UNLESS NOTED ON PLANS, NAIL PER IBC TABLE 2304.10.1. UNLESS NOTED OTHERWISE ALL NAILS SHALL BE COMMON. NAIL SIZES SPECIFIED ON THE DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: COMMON NAILS SIZE LENGTH DIAMETER 8D 2-1/2" 0.131 " 10D 3" 0.148" 16D 3-1/2" 0.162" 16D SINKER 3-1/4' 0.148" NAILING REQUIREMENTS: PROVIDE MINIMUM NAILING IN ACCORDANCE WITH IBC TABLE 2304.10.1 "FASTENING SCHEDULE" EXCEPT AS NOTED ON THE DRAWINGS. NAILING FOR ROOF/FLOOR DIAPHRAGMS/SHEAR WALLS SHALL BE PER DRAWINGS. NAILS SHALL BE DRIVEN FLUSH AND SHALL NOT FRACTURE THE SURFACE OF SHEATHING. STANDARD LIGHT -FRAME CONSTRUCTION: UNLESS NOTED ON THE DRAWINGS, CONSTRUCTION SHALL CONFORM TO IBC SEC 2308 "CONVENTIONAL LIGHT -FRAME CONSTRUCTION" AND IBC SEC 2304 "GENERAL CONSTRUCTION REQUIREMENTS." (1)WALL FRAMING (UNLESS NOTED OTHERWISE ON PLANS AND DETAILS) ALL INTERIOR WALLS SHALL BE 2X4 ® 16"OC AND ALL EXTERIOR WALLS SHALL BE 2X6 @ 16"OC. PROVIDE (2) BUNDLED STUDS MIN AT WALL ENDS AND EACH SIDE OF ALL OPENINGS. ALL SOLID SAWN LUMBER BEAMS AND HEADERS SHALL BE SUPPORTED BY A MINIMUM OF (1) TRIM AND (1) KING STUD AND ALL GLULAM OR ENGINEERED WOOD BEAMS AND HEADERS BY (2) TRIM AND (2) KING STUDS. PROVIDE MINIMUM 4X1O] HEADERS AT ALL INTERIOR AND EXTERIOR WALL OPENINGS. STITCH -NAIL BUNDLED STUDS WITH (2) 10D @ 12"OC. PROVIDE SOLID BLOCKING THRU FLOORS TO SUPPORTS BELOW FOR BEARING WALLS AND POSTS. ATTACH BOTTOM PLATES OF STUD WALLS TO WOOD FRAMING BELOW WITH 16D @ 12"OC OR TO CONCRETE WITH 5/8"-DIA. ANCHOR BOLTS X 7" EMBEDMENT AT 48"OC. REFER TO SHEAR WALL SCHEDULE FOR SPECIFIC SHEATHING, STUD, AND NAILING REQUIREMENTS AT SHEAR WALLS. PROVIDE GYPSUM SHEATHING ON INTERIOR SURFACES AND PLYWOOD SHEATHING ON EXTERIOR SURFACES. (2)ROOF/FLOOR FRAMING: (UNLESS NOTED OTHERWISE ON PLANS AND DETAILS) PROVIDE DOUBLE JOISTS/RAFTERS UNDER ALL PARALLEL BEARING PARTITIONS AND SOLID BLOCKING AT ALL BEARING POINTS. PROVIDE DOUBLE JOISTS AROUND ALL ROOF/FLOOR OPENINGS. MULTI-JOISTS/RAFTERS SHALL BE STITCH -NAILED TOGETHER WITH (2)10D ® 12"OC. PROVIDE ROOF SHEATHING EDGE CLIPS CENTERED BETWEEN FRAMING AT UNBLOCKED PLYWOOD EDGES. ALL FLOOR SHEATHING SHALL HAVE TONGUE AND GROOVE JOINTS OR BE SUPPORTED BY SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF ROOF/FLOOR SHEATHING. ROOF/FLOOR SHEATHING SHALL BE LAID FACE GRAIN PERPENDICULAR TO FRAMING MEMBERS. MOISTURE CONTENT: WOOD MATERIAL USED FOR THIS PROJECT SHALL HAVE MAXIMUM MOISTURE CONTENT OF 19% EXCEPT FOR THE PRESSURE -TREATED WOOD SILL PLATE. PRESERVATIVE TREATMENT: WOOD MATERIALS ARE REQUIRED TO BE "TREATED WOOD" UNDER CERTAIN CONDITIONS IN ACCORDANCE WITH IBC SEC 2304.12 "PROTECTION AGAINST DECAY AND TERMITES." CONFORM TO THE APPROPRIATE STANDARDS OF THE AMERICAN WOOD -PRESERVERS ASSOCIATION (AWPA) FOR SAWN LUMBER, GLUED LAMINATED TIMBER, ROUND POLES, WOOD PILES, AND MARINE PILES. FOLLOW AMERICAN LUMBER STANDARDS COMMITTEE (ALSC) QUALITY ASSURANCE PROCEDURES. PRODUCTS SHALL BEAR THE APPROPRIATE MARK. METAL CONNECTORS/PT WOOD: ALL METAL HARDWARE AND FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE STAINLESS STEEL TYPE 316L. AT THE OWNER'S RISK AND DISCRETION, HOT -DIPPED GALVANIZED METAL HARDWARE AND FASTENERS MAY BE INVESTIGATED FOR USE IN LIEU OF STAINLESS STEEL PROVIDED THAT THE FINISH HAS A MINIMUM ZINC CONTENT OF AT LEAST 1.85 OZ./SF AND ITS USE IS COORDINATED BY THE CONTRACTOR AND WOOD SUPPLIER FOR THE EXPECTED ENVIRONMENT AND MOISTURE EXPOSURE FOR APPROPRIATE USE BASED ON THE METHOD OF PRESERVATIVE TREATMENT OF THE WOOD. APPROVED PLANS MUST BE ON JOB SITE City of Edmonds Building Department APPROVED Plans City Of Edmonds Building Department Work Remodel, Plumbing and Mechanical included Address 8706 Olympic View Drive �_ Owner ' Spratt, Kevin Approved Date 10/18/2020 ---------------------------------------------------- Building Official Permit Number BLD2020-0994 , ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES RESUB Oct 15 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N w Q 0 z Q O z w ()o Q = Q � 00 o a' z � L Q w w z z z - 00 w 000 O O 9/27/2020 1 N 0 00 LLJ < L_LJ Lw U-) 0 W 0 U� Q W W U cn L_L1 � W � < (-n L�J � Z Z LL1 CD w 0 0 00 CHK BY: DRW BY: L2E TNT SCALE: AS SHOWN BAR = 1 " FULL SIZE 1L1IaIk WAFAW1 111 JOB NO: 20-070 SHEET: 1 OF 4 LAG BOLTS/BOLTS: CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. DWG N 0: S 1 O O z 0 U z 0 U ry 0 0 z I w cn U W U r-_ II ---- I II I I II I I II I I �I ------------------- --- —_=� ----------- I� II II I I I I I � I I I I I I I I I I J I I I I I I I I (E) WOOD WALL FRAMING TYP INTERIOR I ------------ ----------- I II TYP @ JAMB STUDS ABOVE I I 4 I S300 I I I I I o� I II I I II I Flo I II I C4 I I I w° I II I I II I I II I --— — — — — — — — — II L-- ---------------- (F) HDR PROVIDE (2)2x STUDS FROM LOW HDR TO 1ST FLR FRAMING BENEATH (N) JAMB STUDS ABOVE 16'-1" - - - - - - - - - - - � -1 (E) CONIC FOOTING, TYP (E) CONIC STEM WALL, TYP I I I I I I — I i PARTIAL FOUNDATION -FIRST FLOOR PLAN SCALE: 1 /4"=1'-0" cc rn PLAN NOTES: 1. ALL DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY. 2. CONTRACTOR TO FIELD VERIFY EXISTING JOISTS SIZES AND SPAN DIRECTIONS SHOWN ON PLAN. NOTIFY FOR IF OTHERWISE. 3. - - - - INDICATES WOOD BASEMENT WALL BELOW. 4. o INDICATES MAIN FLOOR WALL ABOVE. 5. MAIN FLOOR WALLS SHOWN ON THIS SHEET FOR CONTEXT ONLY. SEE S201 FOR FURTHER INFO. 6. IF CONDITIONS OTHER THAN WHAT HAVE BEEN ASSUMED ARE FOUND, CONTACT FOR FOR FURTHER INSTRUCTIONS. RESUB Oct 15 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N LL CD W N w Z z Q 0 O 00 W z z 0 z C7) Li z QW-' z w z CD 0 z o w 0 � w z 0 w w a 0 9/27/2020 1 N O 00 w o-) w < O w U-) Q 0 n w O Z O� O z � w W � Q 0 � Z w O � W � � � Q � U � Q w O O 00 CHK BY: DRW BY: L2E I TNT SCALE: AS SHOWN BAR = 1 " FULL SIZE DATE:09-27-2020 JOB NO: 20-070 SHEET: 2 OF 4 DWG NO: S200 z 0 U w z 0 U ry 0 0 z I w cn U W U m (E) HDR ,N) SOUND WALL 2x4 @ 16"OC, STAGGERED ON 2x6 PLATE, SEE ARCH DWGS ,E) WALL TO BE REMOVED. CONTR TO VERIFY CEILING JOISTS ARE NOT SPLICED OVER THIS WALL PRIOR TO REMOVAL. NOTIFY FOR IF SPLICE EXISTS AT THIS LOCATION DORTION OF EXT WALL TO BE INFILLED W/ 2x4 9 16"OC, TYP UNO CONTR TO PROVIDE TEMP SHORING ON EA SIDE OF WALL PRIOR TO (E) WALL REMOVAL, TYP (2) LOCS, WHERE SHOWN. PORTION OF (E) EXT WALL TO BE REMOVED, TYP I (2)2xI U (2)2x10 (2)2x1 U 1 PARTIAL MAIN FLOOR CEILING FRAMING PLAN SCALE: 1 /4"=1 '-0" 00 ro PLAN NOTES: 1. ALL DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY. 2. CONTRACTOR TO FIELD VERIFY ALL EXTERIOR WALLS ARE SHEATHED WITH PLYWOOD SHEATHING. NOTIFY FOR IF OTHERWISE. 3. NEW EXTERIOR INFILL WALLS TO BE SHEATHED WITH 15/2" APA RATED SHEATHING. 8d NAILS @ 6"OC PANEL EDGES, 8d NAILS @ 12"OC FIELD. 4. NEW INTERIOR HEADERS TO BE (2)2x8, NEW EXTERIOR HEADERS TO BE (2)2x10, TYPICAL UNLESS NOTED OTHERWISE ON PLAN. SEE DETAIL 3/S300. 5. CONTRACTOR RESPONSIBLE FOR ALL SHORING REQUIRED FOR WALL REMOVAL. 6. _ _ _ = INDICATES EXISTING WALL TO BE REMOVED. 7. INDICATES NEW WALL FRAMING. 8. ALL WALLS SHOWN ARE MAIN FLOOR WALLS BELOW EXISTING CEILING. 9. IF CONDITIONS OTHER THAN WHAT HAVE BEEN ASSUMED ARE FOUND, CONTACT FOR FOR FURTHER INSTRUCTIONS. RESUB Oct 15 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N LL W N w Z z Q w O 00 W z z 0 CD z C7) Li z Q W z -I w z 0 z o w 0 � w z 0 w w w Q 0 9/27/2020 1 N O 00 w o-) � � 0 0 0 n n LJJ O Q z LL--- W W 0 n--, O W O In-,0 w L� In � W Z Q � U n W O O 00 CHK BY: DRW BY: L2E I TNT SCALE: AS SHOWN BAR = 1 " FULL SIZE 171111alllwzArloyill JOB NO: 20-070 SHEET: 3 OF 4 DWG NO: S 2 0 1 (E) CEILING JOIST, TYP GYP PER ARCH BLOCKING \N NOTE: FRAMING ABOVE NOT SHOWN FOR CLARITY. DETAIL 1 SCALE: 1"=1'-0" (N) COMPENSATED WALL - PARALLEL TO (E) JOISTS z 0 U ry z 0 U CK 0 w 0 z I CEILING JOIST SPLICE WHERE OCCURS. VERIFY MIN 2" BEARING (E) CEILING JOIST, TYP GYP PER ARCH SIMPSON H3 CLIP ® EVERY OTHER JOIST (ALT. CONNECTION: (1) 16D EACH JOIST EACH SIDE) WALL FRAMING PER PLAN NOTE: 1) ROOF FRAMING ABOVE NOT SHOWN FOR CLARITY. 2) CONTACT FOR IF SPLICE OCCURS BEYOND PROPOSED WALL FOR ALTERNATE CONNECTION. D ETAI L 2 SCALE: 1 "1 '-0" (N) BRG. WALL — PERP. TO (E) CEILING JOISTS F TRIMMER P NOTE: 1) (E) FRAMING ABOVE AND WALL SHEATHING NOT SHOWN FOR CLARITY. DETAIL 3 SCALE: 1 "=1'-0" (N) HEADER 2X DBL RD§L�-Iffi PLAN, TYP ALL FRAMING PER AN AND GSN ) 16d END JLS, TYP k�j i -1\ i 1-vill- C ) z W Q N o W W z z 00 AN. JAMB Z w = °O Q o z 0-) W FULL ULr IF] LA oLVV�ING W/ SIMPSON LUS HANGER EA SIDE TYP ® NEW JAMB STUDS. NOTE: 1) SEE PLAN FOR LOCATION OF JAMB STUDS AT NEW HEADERS. D ETAI L 4 SCALE: 1 "=1'-0" (N) BLOCKING DETAIL AT (N) JAMB STUDS RESUB Oct 15 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT z Q w w LIJ z z z 0 0 o w o00 0 N W � W z 0 w ry w Q 0 9/27/2020 1 N O 00 W < O W u/ � W (-n WO Q U � W Z � � W W 0 � C2 Q W 0 � � � U � W � 0 U (-n W = � W 0 W O 00 CHK BY: DRW BY: L2E TNT SCALE: AS SHOWN BAR = 1 " FULL SIZE DATE:09-27-2020 JOB NO: 20-070 SHEET: 4 OF 4 DWG NO: S300