REVIEWED BLD BLD2020-0994+Structural_Analysis_or_Calculations+10.15.2020_11.52.08_AML2 ENGINEERS, LLC
17848 NE 198th Place
Woodinville, WA 98072
STRUCTURAL CALCULATIONS
Spratt Residence
8706 Olympic View Drive
Edmonds, WA 98026
Kevin Spratt
Project # 20-070
September 27, 2020
9/27/2020
L
L2 Engineers, LLC 1 17848 NE 198th Place, Woodinville, WA 98072 1 206-251-2346
L2 ENGINEERS, LLC
17848 NE 198th Place
Woodinville, WA 98072
TABLE OF CONTENTS
• Gravity Calculations
• Lateral Calculations
Ipm
L2 Engineers, LLC 1 17848 NE 198th Place, Woodinville, WA 98072 1 206-251-2346
L2 ENGINEERS, LLC
17848 NE 198th Place
Woodinville, WA 98072
Gravity Calculations
Ipm
L2 Engineers, LLC 1 17848 NE 198th Place, Woodinville, WA 98072 1 206-251-2346
Project Title:
Engineer:
Project ID:
Project Descr:
Printed: 16 SEP 2020, 5:46PN
Wood Beam File: Spratt.ec6
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.1'
DESCRIPTION: Interior Header- 6.25' Max
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set: ASCE 7-16
Material Properties
Analysis Method: Allowable Stress Design
Fb +
575.0 psi
E : Modulus of Elasticity
Load Combination ASCE 7-16
Fb -
575.0 psi
Ebend- xx 1,100.0 ksi
Fc - Prll
575.0 psi
Eminbend - xx 400.0 ksi
Wood Species : Hem -Fir
Fc - Perp
405.0 psi
Wood Grade : No.2
Fv
140.0 psi
Ft
375.0 psi
Density 26.840pcf
Beam Bracing : Completely Unbraced
91106y111FDA
2-2x8
Span = 6.250 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.010, L = 0.010 ksf, Tributary Width = 15.0 ft, (Ceiling)
DESIGN SUMMARY
•
Maximum Bending Stress Ratio =
0.979.1 Maximum Shear Stress Ratio =
0.374 :1
Section used for this span
2-2x8
Section used for this span
2-2x8
fb: Actual =
668.85psi
fv: Actual =
52.38 psi
Fb: Allowable =
683.24psi
Fv: Allowable =
140.00 psi
Load Combination
+D+L
Load Combination
+D+L
Location of maximum on span =
3.125ft
Location of maximum on span =
5.657ft
Span # where maximum occurs =
Span # 1
Span # where maximum occurs =
Span # 1
Maximum Deflection
Max Downward Transient Deflection
0.049 in Ratio =
1517 >=360
Max Upward Transient Deflection
0.000 in Ratio =
0 <360
Max Downward Total Deflection
0.099 in Ratio =
758 >=240
Max Upward Total Deflection
0.000 in Ratio =
0 <240
Project Title:
Engineer:
Project ID:
Project Descr:
Printed: 16 SEP 2020, 5:25PM
Wood Beam File: Spratt.ec6
Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.1'
KW-06011909 L2 Engineers
DESCRIPTION: Exterior Header - Worst Case
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set: ASCE 7-16
Material Properties
Analysis Method: Allowable Stress Design
Fb +
575 psi
E : Modulus of Elasticity
Load Combination ASCE 7-16
Fb -
575 psi
Ebend- xx 1100 ksi
Fc - Prll
575 psi
Eminbend - xx 400 ksi
Wood Species : Hem -Fir
Fc - Perp
405 psi
Wood Grade : No.2
Fv
140 psi
Ft
375 psi
Density 26.84pcf
Beam Bracing : Completely Unbraced
D(0.075) L(0.075)
D(0.255) Lr(0.34) S(0.425)
2-2x10
Span = 5.0 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations
Uniform Load : D = 0.0150, Lr = 0.020, S = 0.0250 ksf, Tributary Width =17.0 ft, (Roof)
Uniform Load : D = 0.010, L = 0.010 ksf, Tributary Width = 7.50 ft, (Ceiling)
DESIGN SUMMARY
nmmm•�
Maximum Bending Stress Ratio =
0.921: 1 Maximum Shear Stress Ratio =
0.439 :1
Section used for this span
2-2x10
Section used for this span
2-2x10
fb: Actual =
661.80psi
fv: Actual =
70.75 psi
Fb: Allowable =
718.93psi
Fv: Allowable =
161.00 psi
Load Combination
+D+S
Load Combination
+D+S
Location of maximum on span =
2.500ft
Location of maximum on span =
0.000ft
Span # where maximum occurs =
Span # 1
Span # where maximum occurs =
Span # 1
Maximum Deflection
Max Downward Transient Deflection
0.028 in Ratio =
2172 >=360
Max Upward Transient Deflection
0.000 in Ratio =
0 <360
Max Downward Total Deflection
0.049 in Ratio =
1222 >=240
Max Upward Total Deflection
0.000 in Ratio =
0 <240
L2 ENGINEERS, LLC
17848 NE 198th Place
Woodinville, WA 98072
Gravity Calculations
Ipm
L2 Engineers, LLC 1 17848 NE 198th Place, Woodinville, WA 98072 1 206-251-2346
Project Title:
Engineer:
Project ID:
Project Descr:
Printed: 17 SEP 2020, 5:49PM
File: Sp
Wood Beam
Software copyright ENERCALC, INC. 1983-2020, BuiId:12.20.2.20.8.1.1'
KW-06011909 L2 Engineers
DESCRIPTION: (E) Joist Check - At New Guest Room
CODE REFERENCES
Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16
Load Combination Set: ASCE 7-16
Material Properties
Analysis Method: Allowable Stress Design
Fb +
Load Combination ASCE 7-16
Fb -
Fc - Prll
Wood Species : Douglas Fir -Larch
Fc - Perp
Wood Grade : Select Structural
Fv
Ft
Beam Bracing : Beam is Fully Braced against lateral -torsional buckling
D(0.01995)
L(0.053
2x10
Span = 14.0 ft
1500 psi
E : Modulus of Elasticity
1500 psi
Ebend- xx 1900 ksi
1700 psi
Eminbend - xx 690 ksi
625 psi
180 psi
1000 psi
Density 31.21 pcf
Repetitive Member Stress Increase
D(0.24),
L(0.24)
Applied Loads
Service loads entered. Load Factors will be applied for calculations.
Uniform Load : D = 0.0150, L = 0.040 ksf, Tributary
Width =1.330 ft, (Floor Load)
Point Load : D = 0.240, L = 0.240 k @ 10.50 ft,
(Jamb Load)
DESIGN SUMMARY
•
Maximum Bending Stress Ratio =
0.807. 1 Maximum Shear Stress Ratio =
0.490 : 1
Section used for this span
2x10
Section used for this span
2x10
fb: Actual =
1,531.85psi
fv: Actual =
88.21 psi
Fb: Allowable =
1,897.50psi
Fv: Allowable =
180.00 psi
Load Combination
+D+L
Load Combination
+D+L
Location of maximum on span =
8.635ft
Location of maximum on span =
13.234ft
Span # where maximum occurs =
Span # 1
Span # where maximum occurs =
Span # 1
Maximum Deflection
Max Downward Transient Deflection
0.334 in Ratio =
503 >=360
Max Upward Transient Deflection
0.000 in Ratio =
0 <360
Max Downward Total Deflection
0.514 in Ratio =
327 >=240
Max Upward Total Deflection
0.000 in Ratio =
0 <240
L2 ENGINEERS, LLC
17848 NE 198th Place
Woodinville, WA 98072
Lateral Calculations
Ipm
L2 Engineers, LLC 1 17848 NE 198th Place, Woodinville, WA 98072 1 206-251-2346