Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2021-0048+Fire_Sprinkler_Equipment_Specification_Sheets+5.12.2021_11.34.07_AM+2192621
lColumbia Fire 110INKE EB 5v 51 EfA Sf RVICE i REPA MANUFACTURER'S DATA SHEETS (Material Submittal) Prepared For Heldridge Residence Authority Having Jurisdiction CITY OF EDMONDS Prepared By: Marco Bellutta Columbia Fire Inc. 111 South Findlay St. Seattle WA 98108 Phone: (206) 232-8569 Fax (206) 340-6100 Columbia Fire Project #:2102055 TABLE OF CONTENTS 1. Piping 2. Fittings / Couplings 3. Sprinkler Heads and Accessories 4. Miscellaneous Hanging Components Riser, Back Flow 1. PIPING Tyco Fire Protection Products 6 LAZ E MASTE R CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description TYCO CPVC Pipe and Fittings pro- duced by Tyco Fire Protection Prod- ucts (TFPP) are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermo- plastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch thru 3 Inch Maximum Working Pressure 175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved City of Los Angeles (Refer to Installation Handbook IH-1900 dated June 2008 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange Worldwide I www.tyco-fire.com Contacts Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900 dated April 2016. Page 1 of 2 APRIL 2016 TFP1915 TFP1915 Page 2 of 2 Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de -vices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. t[�CO BLAZEMASTER is a trademark of The Lubrizol Corporation. Fire Protection Products 2. FITTINGS / COUPLINGS Sprinkler Head Adapters BRASTICTm Adapter Straight Size (inches) Part Number Box Qty 3/4 x 1/2 V5003SBT--101 100 1 x 1/2 V5003SBT-130 50 1 x 3/4 V5003SBT-131 50 900 Elbow 3/4x1/2 V50073SBT-101 100 1 x 1/2 V50073SBT-130 50 1 x 3/4 V50073SBT-131 50 Tee 1 x 1 x 1 V5012SBT-101 50 1 x 1 x 1/2 V5012SBT-130 50 1 x 1 x 3/4 V5012SBT-010 50 * Brass starter thread molded into plastic, virtually eliminating cross -threading. Female Adapter with metal thread insert 3/4 x 1/2 1 x 1/2 1 x 3/4 V5003SBI-101 V5003SBI-130 V5003SBI-131 100 50 10 Spigot Female Adapter 3/4x 1/2 100 with metal thread insert 1 x 1/2+V50032SBI-101 V500325BI-130 50 #a Sprinkler Head 90 3/4 x 1/2 V50073SBI-101 100 with metal thread insert 1 x 1/2 1 x 3/4 V50073SBI-130 V50073SBI-131 50 10 1-1/4x1/2 V50073SBI-166 5 Tee Size (inches) Part Number Box Qty with metal thread insert 1 x 1 x 1 V5012SBI-010 50 3/4x3/4x1/2 V5012SBI-101 10 1 x 1 x 1/2 V5012SBI-130 50 1-1/4x 1-1/4x 1/2 V5012SBI-166 5 1-1/2 x 1-1/2 x 1/2 V5012SBI-209 5 2 x 2 x 1/2 V5012SBI-247 2 1 x3/4x 1/2 V5012RSBI-124 10 1-1/4x 1 x 1/2 V5012RSBI-156 5 1-1/2x 1-1/4x 1/2 V5012RSBI-199 5 2 x 1-1/2 x 1/2 V5012RSBI-237 2 Back to Back Cross 1x1x1/2x1/2(1-1/8)1 V50353SBIS-130 20 with metal thread insert — 1x1x12x1/2(t-5n6) V50353SBIL-130 1 Back to Back Tee 11/2x1/2x1(1-1i8) V501133SBIS-075 30 with metal thread insert4& — I 1/2x1/2x1 (t-s/t6) V5011335BIL-075 30 Trusted above aII.T" V�KING� CPVC System Quick Reference Guide CPVC Standard Fittings Tee Size (inches) Part Number Box Qty 3/4 V5011-007 250 Qt 1 V5011-010 100 1-1/4 V5011-012 25 1-1/2 V5011-015 25 2 V5011-020 2 2-1/2 V5011-025 1 3 V5011-030 1 900 Elbow 3/4 V5007-007 250 r 1 V5007-010 100 1-1/4 V5007-012 25 1-1/2 V5007-015 25 2 V5007-020 2 2-1/2 V5007-025 1 3 V5007-030 1 1 x 3/4 V5007R-131 100 450 Elbow 3/4 V5006-007 250 1 V5006-010 100 1-1/4 V5006-012 5 1-1/2 V5006-015 5 2 V5006-020 2 2-1/2 V5006-025 1 3 V5006-030 1 Cross 3/4 V5035-007 10 1 V5035-010 100 1-1/4 V5035-012 5 1-1/2 V5035-015 20 2 V5035-020 1 2-1/2 V5035-025 1 1 x 1 x 3/4 x 3/4 V5035R-131 10 Coupling 3/4 V5001-007 250 1 V5001-010 100 1-1/4 V5001-012 25 1-1/2 V5001-015 25 2 V5001-020 10 2-1/2 V5001-025 1 3 V5001-030 1 Reduced Coupling 1 x 3/4 V5001 R-131 10 1-1/4 x 1 V5001 R-168 5 40 1-1/2 x 3/4 V5001 R-210 5 1-1/2x1 V5001R-211 5 1-1/2x1-1/4 V5001R-212 5 2 x 1 V5001 R-249 2 2 x 1-1/2 V5001 R-251 2 N Reducing Tee Size (inches) Part Number Box Qty r 3/4 x 3/4 x l V501 1 R-102 10 1 x 3/4 x 3/4 V5011 R-125 100 l x 3/4 x l V5011 R-126 10 1 x l x 3/4 V5011 R-131 100 1-1/4x 1 x3/4 V5011R-157 5 1-1/4x 1 x 1 V5011R-158 25 1-1/4x 1 x 1-1/4 V5011R-159 5 1-1 /4 x 1-1 /4 x 3/4 V5011R-167 25 1-1/4x1-1/4x1 V5011R-168 25 1-1/4x 1-1/4x 1-1/2 V5011R-169 5 1-1/2 x 1-1/4 x 3/4 V5011R-201 5 1-1/2x1-1/4x1 V5011R-202 5 1-1 /2 x 1-1 /2 x 3/4 V5011R-210 25 1-1/2x1-1/2x1 V5011R-211 25 1-1/2x 1-1/2x 1-1/4 V5011R-212 5 1-1/2 x 1-1/2 x 2 V5011R-213 5 2 x 2 x 3/4 V5011 R-248 2 2 x 2 x 1 V5011 R-249 10 2 x 2 x 1-1 /4 V5011 R-250 2 2 x 2 x 1-1/2 V5011 R-251 2 2-1/2 x 2-1/2 x 1 V5011 R-289 1 2-1/2 x 2-1/2 x 1-1 A V5011R-290 1 2-1/2 x 2-1/2 x 1-1 /2 V5011R-291 1 2-1/2 x 2-1/2 x 2 V5011R-292 1 3 x 3 x 1-1/2 V5011 R-337 1 3 x 2 V5011 R-338 1 3 x 2-1/2 V5011 R-339 1 Bushing 1 x3/4 V5018-131 100 1-1/4 x 3/4 V5018-167 25 IN 1-1/4x1 V5018-168 25 1-1/2 x 3/4 V5018-210 5 1-1 /2 x 1 V5018-211 25 1-1/2x1-1/4 V5018-212 25 2 x 3/4 V5018-248 2 2 x 1 V5018-249 2 2x1-1/4 V5018-250 2 2x1-1/2 V5018-251 2 2-1/2 x 1 V5018-289 15 2-1/2 x 1-1 /4 V5018-290 1 2-1/2x1-1/2 V5018-291 1 2-1/2 x 2 V5018-292 1 3 x 1-1/2 V5018-337 15 3 x 2 V5018-338 1 3 x 2-1/2 V5018-339 1 Cap 3/4 V5017-007 250 1 V5017-010 100 1-1/4 V5017-012 5 1-1/2 V5017-015 5 2 V5017-020 2 2-1/2 V5017-025 1 3 V5017-030 1 November 2014 CPVC System Quick Reference Guide 3 CPVC Pipe Size (inches) Part Number Box Qty 3/4 34PIPE 240 1 1 PIPE 180 ,ir 1-1/4 114PIPE 105 • • 1-1/2 112PIPE 75 ���► 2 2PIPE 60 2-1/2 212PIPE 30 3 3PIPE 15 CPVC Transition Fittings Female Adapter Size (inches) Part Number Box Qty %,rvuveu k.-uuPiirry Size (inches) Part Number Box Qty with metal thread insert Adapter 3/4 V500361-007 10 1-1/4 V5001G-012 30 1 V5003BI-010 50 1-1/2 V5001G-015 25 1-1/4 V5003BI-012 5 2 V5001G-020 15 1-1/2 V5003BI-015 5 2-1/2 V5001G-025 4 2 V5003BI-020 2 3 V5001G-030 2 Spigot Female Adapter 3/4 V50032BI-007 250 Standard Union 3/4 V5033E-007 1 with metal thread insert 1 V50032BI-010 100 1 V5033E-010 1 Male Adapter 3/4 V5004BI-007 10 with metal thread insert 1 V5004BI-010 10 1-1/4 V5004BI-012 5 1-1/2 V5004BI-015 5 2 V5004BI-020 2 Accessories Solvent Cement Test Plug Size (inches) Part Number Box Qty Dauber Quart V5097Q 12 Pint V5097P 12 1/2 V450-005 50 Size (inches) Part Number Box Qty Small V5093-S 100 Large V5093-L 100 Roller N/A a - Brush N/A V5097 24 V5096 12 November 2014 CPVC System Quick Reference Guide 4 Recommended Installation Practices and Precautions for Freedom' CPVC Systems Dos • Install product according to the manufacturer's instructions. • Follow recommended safe work practices. • Make certain that thread sealants, gasket lubricants, or fire stop materials are compatible with BlazeMaster® CPVC. Use only latex -based paints if painting is desired. Keep pipe and fittings in original packaging until needed. Cover pipe and fittings with an opaque tarp if stored outdoors. Follow proper handling procedures. Use tools designed for use with plastic pipe and fittings. • Use proper solvent cement and follow application instructions. • Use a drop cloth to protect interior finishes. • Cut the pipe ends square. • Deburr and bevel the pipe end before solvent cementing. • When solvent cementing, rotate the pipe 1/4 turn when bottoming pipe in fitting socket. • Always apply solvent cement to the pipe first then fitting. • Avoid puddling of solvent cement in fittings and pipe. • Make certain that solvent cement does not run and plug the sprinkler head orifice. • Follow the manufacturer's recommended cure times prior to pressure testing. • Fill lines slowly and bleed the air from the system prior to pressure testing. • Support sprinkler head properly to prevent lift up of the head through the ceiling when activated. Keep threaded rod within 1/16"of the pipe. • Install BlazeMaster CPVC pipe and fittings in wet systems only or specially listed dry systems. • Follow manufacturer'hs recommendations for freeze protection. • Allow for movement due to expansion and contraction. • Renew your BlazeMaster CPVC pipe and fittings installation training every two years. • Follow manufacturer's recommendations on pressure testing. • Follow current NFPA standards for use of antifreeze solutions. Blazemaster' is a registered trademark of Lubrizol Teflon' is a registered trademark of E. I. du Pont de Nemours and Company Crisco' is a registered trademark of the J.M. Smucker Company Regional Headquarters Don'ts • Do not use petroleum or solvent -based paints, sealants, lubricants or fire stop materials. • Do not use any glycol -based solutions as an anti -freeze. • Do not use both Teflon' tape and thread sealants simultaneously. • Do not use solvent cement that exceeds its shelf life or has become discolored or gelled. Do not allow solvent cement to plug the sprinkler head orifice. Do not connect rigid metal couplers to BlazeMaster® CPVC grooved adapters. Do not thread BlazeMaster CPVC pipe. Do not use solvent cement near sources of heat, open flame, or when smoking. Do not pressure test until recommended cure times are met. Do not use dull or broken cutting tool blades when cutting pipe. Do not use BlazeMaster CPVC pipe that has been stored outdoors unprotected and is faded in color. Do not allow threaded rod to come in contact with the pipe. Do not install BlazeMaster CPVC pipe in cold weather without allowing for expansion. • Do not install BlazeMaster CPVC pipe and fittings in dry systems, unless specifically Listed for such use. • Do not use ratchet cutters below 50•F. • Do not use edible oils such as Crisco® as a gasket lubricant. • Do not install tape, insulated wire, or cable in direct contact with BlazeMaster CPVC pipe. Note:This list does not constitute as a complete installation guide. Viking SupplyNet - U.S. East Viking SupplyNet - U.S. Midwest Viking SupplyNet - U.S. West 413 Cranberry Rd 2353 International St 9101 Sorensen Ave. Parsippany, NJ 07054 Columbus, OH 43228 Santa Fe Springs, CA 90670 Phone: 800-845-4645 Phone: 800-926-7757 Phone: 800-366-1727 Fax: 269-818-1639 Fax: 614-527-5818 Fax: 562-944-1058 Viking SupplyNet - U.S. South Viking SupplyNet - Latin America Viking SupplyNet -Canada 100 Piedmont Court, Suite A 2840 SW 42nd St, Port 95 Ind Ctr Blg IV 325 Vaughan Valley Blvd. Doraville, GA 30340 Hollywood, FL 33312 Woodbridge, Ontario L4H 365 Phone: 800-234-2443 Phone: 954-791-1756 Phone: 905-856-3557 Fax: 770-446-3713 Fax: 954-791-1614 Fax: 905-856-3558 November 2014 Viking 1210 N Industrial Park Drive, Hastings, MI 49058,Telephone: (269) 945-9501, Facsimile: (269) 945-95991 www.vikinggroupinc.corn MKT-1089 3. Sprinkler Heads and Accessories Page 1 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom° Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS c u� as UL Listed (C-UL-US-EU): Category VKKW eu Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass -bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom° Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Standard Cover Plates: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Form No. F_012116 18.04.12 Rev 18.1 Replaces Form No. F_012116 Rev 17.2 (added stainless steel cover plates) Page 2 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = MA, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031 *** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ''/z' ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly.. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Bulb Color Classification Temperature Ceiling Assembly Base Part Base Part Base Part Rating' Temperature' (Required)' Number' Number' Number' 13504 or 13642 or Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 15394 Red 218766 218756 13504 or 13642 or Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 15394 Green 218766 218756 Sprinkler Finishes: Brass and ENT Cover Plate Finishers: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings5: ENT Footnotes The sprinkler temperature rating is stamped on the deflector. z. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 6. Stainless Steel versions are not available with any finishes or paint. Form No. F_012116 18.04.12 Rev 18.1 Page 3 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart Viking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number 1 SIN king Pressure Inches mm U.S. metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage Flow Pressure Listings and Minimum Area 6 GPM (LPM) PSI(bar) Deflector to Installation Approvals3,5 Spacing Ceiling Type Ft. 155 °F (68 °C), 200 of (93 °C) Temperature (u �`E�'°S Ft. X Ft. (m) (m X m) Rated Sprinklers 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Concealed with Cover Plate See Footnotes T9, 10, 8 16 X 16 13 7.0 (4.9 X 4.9) (49.2) (0.48) Refer to Figure 2 Assembly. See Footnote 8. & 11 (2.4) 18 X 18 17 12.0 (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X 6.1) (75.7) (1.15) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. I This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. a. Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. Meets New York City requirements, effective July 1, 2008. 6 For areas of coverage smaller than shown, use the "Flow' and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and 'Pressure' used. 7 Cover Temperature Rating is 135 of (57 oC). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). a. Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 9. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 8. 10-C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) 11 Stainless Steel Cover plate temperature rating is 135 °F (57 °C). Stainless Steel Cover Part Numbers: 218761 and 218751 (large diameter). Form No. F_012116 18.04.12 Rev 18.1 Page 4 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Reguirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** ^W. Sprinkler Wrench Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: 1 1 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Form No. F_012116 18.04.12 Rev 18.1 Page 5 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1/2" (15 mm) NPT s E N 00 'n 2-9/16" (65 mm) Maximum NOTE: Upon sprinkler activation, the deflector descends to approximately 13116" (21 mm) below the sprinkler body. 2-1/16" (52 mm) Minimum f i- 2-3/4" (70 mm) or 3-5/16" (84 mm) Figure 2: Sprinkler Dimensions and Cover Installation QQ�\�--p C US 7-0 a �2 O c� U� O VII NG All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers - -1 - \- . .... ., Figure 4: Square Cover Assembly 15394 Form No. F_012116 18.04.12 Rev 18.1 Replaces Form No. F-012116 Rev 17.2 (added stainless steel cover plates) Page 1 of 8 ® QUICK RESPONSE DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION Viking Quick Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry HSW Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and AL Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indi- cated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2013 and 2015 For Light Hazard Occupancies Only M, NYC Approved: MEA 89-92-E, Volume 15 Refer to Approval Charts and Design Criteria for Listing and Approval that must be followed. 3. TECHNICAL DATA Specifications: Available since 1993. WARNING: Cancer and Reproductive Harm - Minimum Operating Pressure: 7 psi (0.5 bar) Zt www.P65Warnings.ca.gov Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1" NPT or 25 mm BSPT Nominal K-Factor: 5.6 U.S. (80.6 metric') for all listed and approved lengths. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass -bulb fluid temperature rated to -65 °F (-55 °C) Covered by the following U.S. Patent numbers: 8,636,075 and 8,376,060 and 10,220,231 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support (Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Order QR Dry HSW Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ("A" dimension) to sprinkler base part number. Order in a specific length noted as the "A" dimension. The "A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the wall in which it is to be installed. These sprinklers are listed and approved in lengths from 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) for the adjustable standard style, 3" to 47" (76.2 mm to 1,194 mm) for the plain barrel style, and 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a "made -to -order" basis: Recessed Dry HSW up to 65- 1/2" (1,664 mm). Adjustable Standard Dry HSW up to 63-1/2" (1,613 mm). Plain Barrel Dry HSW up to 65" (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-NV, and ENT = JN Form No. F_031993 20.04.16 Rev 20.1 Replaces Form No. F_031993 Rev 19.2 (Removed cover 15610.) Page 2 of 8 ® QUICK RESPONSE DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS 4 P 6 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Escutcheon Suffix = Y for the adj. recessed sprinkler with the Model G-1 Escutcheon (no suffix needed for the Model E-1 Escutcheon). For example, sprinkler VK182 with 1" NPT Threads, a Chrome finish, a 155 °F (68 °C) temperature rating, the Model G-1 Escutcheon, and "A" length of 10" = Part No. 08386UFBY10. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section.) Sprinkler Wrenches: A. Standard Wrench: Part No. 07297W/B (available since 1991) B. Wrench for recessed sprinklers: Part No. 07565W/B** (available since 1991) **A'/i' ratchet is required (not available from Viking). Replacement Escutcheons: A. Adjustable Standard Dry Escutcheon: Base Part No. 08086F B. Model E-1 Recessed Dry Escutcheon Cup: Base Part No. 05459A C. Model G-1 Recessed Dry Escutcheon Cup: Base Part No. 20133 INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the water- way. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. Sprinkler s eo s Jeways clarltyCRef�r rjure : r-/ correct defector orlentatlonJ INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. Figure 1: AVAILABILITY Standard Sprinkler Wrench 07297W/B The Viking Quick Response Dry Horizontal Sidewall Sprinkler is available through a network of domestic and international distribu- tors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' CeilingTemperature2 Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F 93 °C 150 °F 65 °C Green High 286 °F 141 °C 225 °F 107 °C Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion -Resistant Coating3,4: White Polyester and ENT in all temperature ratings Footnotes ' The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion -resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indi- cated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT corrosion proof. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. " When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. Form No. F_031993 20.04.16 Rev 20.1 Page 3 of 8 ® QUICK RESPONSE DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com �i )K*Notei A 1/2" ratchet is required, Sprinkler Wrench Part (Not available from Viking) No 07565W/B)K)K for installing recessed dry sprinklers. -------------- (^ i_ ____ _________T_ j I ' 1 Step 1: Carefully slide the Step 2: Press the wrench onto wrench sideways around the J the sprinkler wrench flats and deflector and protective turn slightly to ensure engage - shield as shown ment with the wrench flats. Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Horizontal Sidewall Sprinklers For 'A" Dimension: 1. Determine the distance from the face of TFFFT the tee to the finished face of the wall, 2. Round to the nearest 1/2' (12.7 mm) between 1-1/2' (38.1 mm) and 45-1/2' (1,156 mm). NOTE: The deflector will extend approximately 4-1/8' (104.8 mm) from the wall with 2' +/- 1' (25.4 mm) horizontal adjustment available. �A Minimum wall opening J diameter: 1-3/4' (44.5 mm). Maximum wall opening diameter) 2-1/4' (57 mm), mummmmmumnaw Deflector at Minimum Distance - Finished Ceiling From Wall Finished Wall 4' (102 mm) Minimum 6' (152 mm) Maximums 1 (79.4 mm) 17 3-1/16" l (77,8 mm) � / 5/8' (15,9 ` 1 Sleeve diameter) 1-1/2' (38.1 mm). -13/16' Sleeve finish matches )K (20.6 mm) finish of escutcheon. NOTE1 To locate the deflector at the minimum distance from the wall, with no adjustment available, order the standard dry horizontal sidewall sprink- ler 1' (25.4 mm) shorter than the 'A' Dimension. Deflector at NOTE Maximum Distance To locate the deflector From Wall at the maximum distance from the wall, with no adjustment available, order the standard dry horizontal sidewall sprink- ler 1' (25.4 mm) longer than the 'A' Dimension. May be allowed up to 18' (457 mm) for certain FM installations. Refer to the appropriate installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Figure 3: Adjustable Standard Dry Horizontal Sidewall Sprinkler Slot Deflector _ Slot Push and Rotate Sleeve STEP 1: Align the slot in STEP 2: Push the rounded STEP 3: Pull the escutcheon STEP 4: Push and rotate STEP 5: To minimize the escutcheon with the end of the slot against the away from the near edge the escutcheon onto the visibility of the slot horizontal surface of near edge of the deflector. of the deflector. Move the sleeve, in the escutcheon, the deflector as shown. Push the far side of the near side of the escut- position the slot escutcheon past the deflec- cheon over the deflector, at the top of the Tor, toward the sleeve, sprinkler sleeve. Figure 4: Adjustable Standard Escutcheon Installation Form No. F_031993 20.04.16 Rev 20.1 Page 4 of 8 ® QUICK RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1 (UL) Temperature KEY Quick Response Dry Horizontal Sidewall Sprinklers Finish For Light Hazard Occupancies Only AIX *- Escutcheon (if applicable) Maximum 175 PSI (12 bar) WWP Sprinkler Base Thread Size Nominal Order Length Listings and Approvals' Part No.' SIN Style K-FactorZ Increment (Refer also to Design Criteria on page 106e.) NPT BSPT U.S. metric' Inches mm cULus' NYC6 VdS LPCB (E Ci 08384U VK178 Adjustable Standard 1" -- 5.6 80.6 1/2" 12.7 A1, A5 Al -- -- -- - 16458U -- 25 mm -- 80.6 1/2" 12.7 A1, A5 08386U VK182 Adjustable Recessed 1" -- 5.6 80.6 1/4" 6.35 B2, B6 B2 -- -- - 16454U -- 25 mm -- 80.6 1/4" 6.35 B2, B6 - -- -- 08388U VK174 Plain Barrel ill -- 5.6 80.6 1/2" 12.7 A3 A4 -- -- 16456U 25 mm -- 80.6 1/2" 12.7 A3 Approved Finishes and "A" Dimensions 1* - Chrome, or White Polyester' sprinkler with a Chrome, Brass, or White Polyester Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) Approved Temperature Ratings 2* - Chrome, or White Polyester' with "A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) A - 155 -F (68 -C), 175 -F (79°C), 200 -F 3 - Chrome, Brass, White Polyester', or ENT' with "A" dimensions 3" to 47" (76.2 mm to 1,194 mm) (93 °C), and 286 °F (141 °C) 4 - Chrome or Brass with "A" dimensions 3" to 47" (76.2 mm to 1,194 mm) B - 155 °F (68 °C), 175 °F (79 °C), and 5 - ENT' sprinkler with an ENT' Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 200 -F (93 -C) mm to 1,156 mm) 6 - ENT' with "A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) *Brass Finish is listed and approved but not standard offering, lead times of 6-8 weeks required. (Matching Brass escutcheons are not available.) Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). 3 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed by Underwriter's Laboratories for use in the U.S. and Canada for Light Hazard occupancies only. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 15. ' cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Reguirements: Quick Response Dry Horizontal Sidewall Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edi- tion of NFPA 13 for standard spray sprinklers. • Limited to Light Hazard occupancies only. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft. (1.8 m). • Deflector must be positioned between 4" and 6" (102 mm and 152 mm) below the ceiling. Keep the top of the deflector oriented parallel with the ceiling. • Locate no less than 4" (102 mm) from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT. Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_031993 20.04.16 Rev 20.1 Page 5 of 8 ® QUICK RESPONSE DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY Quick Response Dry Horizontal Sidewall Sprinklers Finish For Light Hazard Occupancies Only AlXFEscutcheon (if applicable) Maximum 175 PSI (12 bar) WWP Sprinkler Base Thread Size Nominal K-Factor2 Order Length Increment FM Approvals° Part No. SIN Style (Refer also to Design Criteria below.) NPT BSP U.S. metric' Inches mm 08384U VK178 Adjustable Standard 1" - 5.6 80.6 1/2" 12.7 Al 16458U -- 25 mm -- 80.6 1/2" 12.7 Al 08386U VK182 Adjustable Recessed 1" -- 5.6 80.6 1/4" 6.35 B2 16454U -- 25 mm -- 80.6 1/4" 6.35 B2 08388U VK174 Plain Barrel 1" -- 5.6 80.6 1/2" 12.7 A3 16456U - 25 mm -- 80.6 1 1/2" 12.7 A3 Approved Finishes and "A" Dimensions 1" - Bright Brass, Chrome, White Polyester, or ENT5 with "A" dimensions 1-1/2" to 45-1/2" (38.1 Approved Temperature Ratings mm to 1,156 mm) 2' - Bright Brass, Chrome, White Polyester, or ENT' with "A" dimensions 3-1/4" to 47-1/2" (82.5 A- 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and mm to 1,207 mm) 286 °F (141 °C) 3 - Brass, Bright Brass, Chrome, White Polyester, or ENT' "A" dimensions 3" to 47" (76.2 mm to B - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) 1,194 mm) "Brass Finish is listed and approved but not standard offering, lead times of 6-8 weeks required. (Matching Brass escutcheons are not available.) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). 3 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. ° This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements: The Dry HSW Sprinklers in the Approval Chart above are FM Approved as quick response Non -storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflec- tor distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accord- ance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_031993 20.04.16 Rev 20.1 Page 6 of 8 ® QUICK RESPONSE DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For 'A' Dimenslorr 1, Determine the distance from the face of the tee to the face of the finished wall. 2. Round to the nearest 1/4' (6.35 mm) between 3-1/4' (83 mm) and 47-1/2' (1,207 mm). NOTF The sprinkler will be recessed approximately 5/16' (7,9 mm) with 5/8' (16 mm) horizontal adjustment available F� A II Minimum wall opening I II vi 2-1/8' (54 mm) diameter. Maximum wall opening 2-1/2' (63.5 mm) diameter, w May be allowed up to 18' (457 mm) for certain FM installations. Refer to the appropriate Installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0 Ceiling Wall —7 4' (102 mm) Minimum 6' (152 mm) Maximum* 5/8' (16 mm) 3-1/16' (77.8 mm) Available Adjustment 1-23/32' (43.7 mm) Minimum 2-11/32' (59,5 mm) Maximum 5/16' (7,9 mm) Outward Adjustment 5/16' (73 mm) Inward Adjustment Figure 5: Adjustable Recessed Dry Horizontal Sidewall Sprinkler with the Model E-1 Escutcheon Side outlet of �\ Tee turned to req'd angle for slope of ceiling Adjustable Adapter Ring Depth, 1-1/16' (27 mm) 1/8' (3.2 mm) Adjustable Outer Cup 2-5/8' 4- (66 ) (102 mm) mm Figure For 'A' Dlmenslorr 1. Measure B Dimension from centerline of the face of the tee to the horizontal centerline of the wall opening. 2. Measure C Dimension from the centerline of the Face of the tee to the finished wall q 3. Calculate 'A' Dimension using; A = ++ C NOTE, A Dimension will provide approximately 1/4' of adjustment in either direction. Ceiling Deflector distance �4-6' (102 to 152 mm) "�Lr%�below the ceiLing,)K Minimum wall openingi When measuring for 2-5/8' (66 mm) diameter, the 'A' Dimension, Maximum wall opening: the exact deflector 3-3/4' (95 mm) diameter. .--Wall distance below the ceiling must be known. C 3( May be allowed up to 18' (457 mm) for certain FM Installations. Refer to the appropriate installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Adjustable Recessed Dry Horizontal Sidewall Sprinkler with the Model G-1 Escutcheon Form No. F_031993 20.04.16 Rev 20.1 Page 7 of 8 ® QUICK RESPONSE DRY HORIZONTAL N4 I Ki SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For "A" Dimension 1, Determine the distance from the face of the tee to the base of the sprinkler. 2 Round to next highest 1/2' (12.7 mm) increment, between 3" (76.2 mm) and 47' (1,194 mm). A Outside diameter; 1-5/16' (33A mm), (Same as 1" (25 mm) Schedule 40 pipe Ceiling Wall 7 4" (102 mm) Minimum 6" (152 mm) Maximumx 2-3/16" (51 mm)1 =47�1 5/8" (16 mm) .Be not exceed 6" (152 mm), Do not recess wrench boss. x May be allowed up to 18' (457 mm) for certain FM installations, Refer to the appropriate installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. Figure 7: Quick Response Plain Barrel Dry Horizontal Sidewall Sprinkler Form No. F_031993 20.04.16 Rev 20.1 Page 8 of 8 ® QUICK RESPONSE DRY HORIZONTAL N4 I KJ SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 5-1/8" a (130.2 mm)—1 Seal the clearance space around the sprinkler barrel to avoid ii ii ii Maximum leakage of air Into the protected area and consequent formation of condensate around the sprinkler frame, which could inhibit -- operation or cause premature operation. Refer to Figure 9, I If humidity and temperature differential causes condensation on the exposed dry sprinkler barrel, consider wrapping the exposed barrel with insulation, foam Insulating tape, or equivalent Install the 1" NPT threaded end of the dry sldewall sprink- ler into the 1" NPT outlet of a malleable iron tee fitting per ANSI B 16,3 (C(ass 150) or cast Iron threaded tee fitting per ANSI 16,4 (Class 125) only, Minimum wall opening: diameter: 1-3/4' (445 mm) Maximum wall opening (Exposed diameter: 2-1/4' (57 mm),Barrel) Ambient xpcsec Barre Ambient Temperature Temperature 40°F/4°C 50'F/l0°C 60'F/16°C of Protected Area## at the Ex p osed Minimum Barrel Discharge End Lengthy■ Face of the of the Sprinkler Tee to the Outer Surface of the Wall In. (mm) In. (mm) In. (mm) 40'F WC) 0 0 0 30'F (-1'0 0 0 0 20'F (-7'C) 4 (100) 0 0 10'F (-12'C) 8 (203) 1 (25.4) 0 0'F (-18'C) 12 (305) 3 (76) 0 -10'F (-23'C) 14 (356) 4 (102) 1 (25.4) -20'F (-29'C)14 (356) 6 (152) 3 (76) -30'F (-34'C) 16 (406) 8 (203) 4 (102) -40'F (-40'C) 18 (457) 8 (203) 4 (102) -50-F (-46'C) 20 (508)10 (254)6 (152) -60-F (-51'C) 20 (508) 10 (254) 6 (152) NOTE To locate the II II II------------------- Deflector at deflector at the IIIIIIIII__________________= Maximum Distance From Wall maximum distance from IIIIIIIII------------------ the wall, with no IIIIIIIII IIIIIIIII 13/16" adjustment available, IIIIIIIII (20.6 mm) Ceiling order the standard IIIIIIIII or horizontal side-4' (102 mm) Minimum wall sprinkler 1" 6' (152 mm) Maximum)K longer than the "A" Sleeve finish matches dimension. escutcheon Up to 2' (50.8 mm) 3-1/16" adjustment is available, (77.8 mm) - 5/8" - (15.9 mm) 3-1/8' (79.4 mm) Minimum 1-1/2' NOTE To locate the (38.1 mm) diameter n ii ii deflector the minimum distance from Outer the wall, with no Surface adjustment available, of the Wall _ order the standard dry horizontal side- ;; wall sprinkler 1" Deflector at shorter than the Minimum Distance From Wall 'A' dimension. #May be allowed up to 18' (457 mm) for certain FM installations. Refer to the appropriate installation standards, including NFPA 13 and/or FM Loss Prevention Data Sheet 2-0. �#The protected area refers to the area below the ceiling, The ambient temperature is the temperature at the discharge end of the sprinkler, For protected area temperatures that occur between the values listed, use the next cooler temperature. #)KThe minimum required barrel length is not the some as the "A" dimension. Refer to Figures 3, 5, 6 and 7 for the "A" dimension. Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities, Figure 8: Dry Horizontal Sidwall Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry HSW Sprinkler is Shown) Figure y: Dry Sprinkler Seal (Adjustable Standard Dry NSW Sprinkler is Shown) Replaces Form No. F_031993 Rev 19.2 Form No. F_031993 20.04.16 Rev 20.1 (Removed cover 15610.) Bulletin 051 February 2021 UL Quick Response FM Standard Response '/2" (13mm) Cover plate Adjustment Features 1. Flat cover plate with threaded attachment. 2. Cover plate available in chrome and white as Stan- dard Finishes. Also available in a wide variety of Special Ap- plication Finishes. 3. Cover plates with gaskets are available to limit dust and air movement through the ceiling. 4. Available in Ordinary or Intermediate temperature rat- ing. 5. Sprinkler available in lengthsfrom 41/4 inches (108mm) to 48 inches (1219mm) in 1/4-inch (6.35mm) incre- ments (see Fig. 1). Approvals & Listings 1. Listed by Underwriters Laboratories and Certified for Can- ada (cULus) as a Quick -response sprinkler for Light and Ordinary Hazard occupancies. UL Guide Number VNIV, Sprinklers, Automatic and Open. 2. FM Approved as a Standard -response sprinkler. Patents The Model G5-56 Dry is covered by the following patents: U.S. 5,775,431 U.S. 5,967,240 Application The Model G5-56 Dry is a cULus Listed Quick Response Con- cealed Dry Pendent sprinkler intended for use in accordance with NFPA 13. The Model G5-56 Dry sprinkler is cULus Listed for use in Light and Ordinary Hazard occupancies. The Model G5-56 Dry is FM Approved as a Standard Re- sponse Concealed Dry Pendent sprinkler intended for use in ac- cordance with FM Loss Prevention Data Sheet 2.0. Product Description The Reliable Model G5-56 Dry sprinkler is a Dry Pendent sprin- kler, where the sealing washer is located at the inlet end of the sprin- kler assembly. The position of the sealing washer is controlled by a fusible element at the opposite end of the sprinkler assembly. The sprinkler is installed with the fusible element at the ceiling of a pro- tected space that may be subject to freezing temperatures and the inlet orifice located in a heated area above the ceiling. Operation of the fusible element allows the sealing washer to move out of the inlet Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler orifice admitting water from the supply piping. The sprinkler uses a fast -response fusible element with an Ordinary, 165°F (74°C), or Intermediate, 212°F (100°C), temperature classification. The Model G5-56 Dry sprinkler has a dropdown deflector design that allows the sprinkler to be recessed into the ceiling and con- cealed by a flat cover plate. The cover plate assembly threads into the sprinkler's cup and provides 'h-inch (13mm) of cover adjust- ment. The cover plate assembly consists of a flat cover plate that is attached to the skirt using either 135°F (57°C) or 165°F (74°C) temperature rated solder. The 135°F (57°C) cover plates are for use with Ordinary temperature classification sprinklers and the 165' (74°C) cover plates are for use with Intermediate temperature clas- sification sprinklers. The Model G5-56 Dry sprinkler is available in lengths ranging from 4'/4 inches (108mm) to 48 inches (1219mm) in'/4-inch (6.35mm) increments (see Fig. 1). The length of the sprinkler must be selected to provide the Exposed Minimum Barrel Length in a Heated Area required by Fig. 2. The Model G5-56 Dry sprinkler is available with 1-inch NPT or ISO 7-1 R1 threaded inlet fittings. The standard inlet fitting includes a long inlet designed to minimize the potential for water, scale, and sediment to accumulate on the sprinkler inlet in wet- and dry -pipe sprinkler systems. For wet -pipe sprinkler system applications where the standard inlet interferes with installation into existing plastic pipe fittings, an inlet fitting is available with a short ("PL') inlet. See Fig. 3 for further information. CD c 0 1 CT N O N Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical Data: Nominal Orifice Size:'/2-inch (15mm) Thread Size: 1-inch NPT per ANSI B2.1 or ISO 7-1 R1 Nominal K Factor: 5.6 (80 metric) Maximum Working Pressure: 175 psi (12 bar) — 100% fac- tory hydrostatically tested to 500 psi (34.5 bar) Sprinkler Installation Wrench: Model FC wrench Sprinkler Identification Number (SIN): RA5114 Materials: See Fig. 4 "A" Dimension Temperature Rating Cover Max. Classification Sprinkler plate Ambient Temp. Ordinary 165°F (74°C) 135°F (57°C) 100°F (38°C) Intermediate 212°F (100°C) 165°F (74°C) 150°F (66°C) �-- —� --- — — — 4 1 — u h L- - System Fitting 2-5/8" [67 mm] Dia. Hole in Ceiling 2-5/16" [59 mm] Nominal Position of Cover Plate Cover Plate Assembly 1 Ceiling 1/4" [6 mm I Min. to 5/8" [16 mm] Max. Dropped Deflector to Ceiling Inlet Threads Sprinkler Cup Assembly 1/2" [12 mm] Total Cover Plate Adjustment 1/4" [6 mm] Cover Plate Adjustment 91." 1 /4" [6 mm] 051 FG01 B Cover Plate Adjustment Fig. 1 Note: The "A' dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI B2.1 [7'/2 threads approximately]. "A" Dim. 4'/4" to 48" (108mm to 1219mm) in W (6.35mm) increments 2. Cover Plate Finishes Standard Finishes White Paint Chrome Special Application Finishes Off White Paint Black Paint Custom Color Paint —Specifj/') Raw Brass (Lacquered) Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(2) Sprinkler Wrench (') Custom color paint is semi -gloss, unless specified otherwise. (2) Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Alloy on the back side. Cover plates are not listed or ap- proved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Optional Cover Plate with Gasket* Model G4/G5 Model G4/G5 SR Gasket QR Gasket Cover Plate Cover Plate (FM Approved) (cULus Listed) * Model G4/G5 QR Gasket and Model G4/G5 SR Gasket cover plates are sold as assembled units including both the cover plate and gasket. Model G4 /G5 QR Gasket and Model G4 /G5 SR Gas- ket cover plates and gaskets are not interchangeable. Installation Instructions When used on wet pipe systems, Reliable Model G5-56 dry pendent sprinklers may be installed in ductile or malleable cast iron threaded tees, or CPVC tees and adapters upon veri- fication that the sprinkler inlet fitting does not interfere with the interior of the fitting (see Figure 3). When used on dry pipe systems, Reliable Model G5-56 dry pendent sprinklers MUST ONLY BE installed in the outlets of ductile or malleable cast iron threaded tees on horizontal pipe such that the inlet of the sprinkler protrudes above the bottom level of the pipe. DO NOT install Reliable dry sprinklers into elbows or cou- plings, welded outlets, mechanical tees, or gasket sealed CPVC fittings. Dry sprinklers connected to wet pipe systems must be in- stalled as indicated in Figure 2 and as required by NFPA 13 with the Exposed Minimum Barrel Length located in a heated area. DO NOT install the Reliable Model G5-56 dry pendent sprin- kler in ceilings that have positive pressure in the space above. The following steps must be followed for installation: 1. Cut a 25/8-inch (67mm) diameter hole in the ceiling directly in -line with the outlet of the tee. 2. Apply pipe joint compound or Polytetrafluoroethylene (PTFE) tape to the threads of the sprinkler's inlet fitting. 3. A protective cap is provided to protect the drop -down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove the cap to install sprinkler, Step 4, then reinstall cap until the cover plate is installed. 4. Install the sprinkler in the tee using the Model FC wrench. The Model FC wrench has a socket drive which is inserted into the sprinkler's cup and around the body of the sprinkler prior to installation of the sprinkler. Do NOT wrench any of the part of the sprinkler/cup assembly. The sprinkler is then tightened into the pipe fitting to achieve a leak free connec- tion. The recommended minimum to maximum installation torque is 22-30 lb-ft (30 — 40 N-m). When inserting or re- moving the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Rein- stall the protective cap following installation of the sprinkler, until the cover plate is installed. a. Alternatively, where access to the outer tube of the sprinkler is available, the Model G5-56 Dry sprinkler may be installed using a pipe wrench. The protec- tive cap should not be removed to install the sprin- kler with a pipe wrench. The pipe wrench shall only be permitted to interface with the steel outer tube portion of the sprinkler (Item #8 in Fig. 4). Do NOT wrench any other portion of the sprinkler/cup as- sembly. A pipe wrench can install the sprinkler into the fitting with a large amount of torque; consider- ation should be given to the need for future removal of the sprinklers because the installation torque will have to be matched or exceeded to remove the sprinkler. The recommended minimum to maximum installation torque is 22-30 lb-ft (30 — 40 N-m). 5. To install the cover plate, remove the protective cap and in- stall the cover plate by hand turning the cover in the clock- wise direction until it is tight against the ceiling. For Model G4 /G5 QR Gasket and Model G4 /G5 SR Gasket cover plates, the gasket should be attached to the flange of the cover plate skirt only. Do not glue the gasket in place or allow the gasket to overlap both the cover plate and the flange of the skirt. 3. is MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM AMBIENT TEMPERATURE OF PROTECTED AREA` AT THE DISCHARGE END OF THE SPRINKLER EXPOSED BARREL AMBIENT TEMPERATURE 40oF/4°C 50°F/10°C 60°F/16°C EXPOSED MINIMUM BARREL LENGTH** (FACE OF TEE TO TOP OF CEILING) IN. (MM) IN. (MM) IN. (MM) 40oF(4oC) 0 0 0 30cF(-1°C) 0 0 0 20oF (-7oC) 4 (100) 0 0 10°F (-12°C) 8 (200) 1 (25) 0 0°F (-18°C) 12 (300) 3 (75) 0 -10°F (-23°C) 14 (350) 4 (100) 1 (25) -20oF (-29°C) 14 (350) 6 (150) 3 (75) -30°F (-34°C) 16 (400) 8 (200) 4 (100) -40oF (-4OoC) 18 (450) 8 (200) 4 (100) -50oF (-46oC) 20 (500) 10 (250) 6 (150) -60oF (-51 oC) 20 (500) 10 (250) 6 (150) * FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. ** THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME AS THE "A" DIMENSION. THE MINIMUM EXPOSED BARREL LENGTH IS BASED ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WIND VELOCITY ON THE EXPOSED SPRINKLER OF 30 MPH (48 KM/H). LONGER EXPOSED BARREL LENGTHS WILL HELP AVOID FREEZING OF THE WET PIPING WHERE HIGHER WIND VELOCITY IS EXPECTED. *** THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSULATION, WALL, OR CEILING LEADING TO THE COLD SPACE, WHICHEVER IS CLOSEST TO THE FITTING. WET PIPE F------- _-j fill —`— — — t —� NOTE: TEE MAY BE IN ANY — ORIENTATION FOR WET PIPE SYSTEMS. L- - IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSE CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT. MINIMUM (HEATED AREA) IF NECESSARY, SEAL THE CLEARANCE SPACE EXPOSED AROUND THE SPRINKLER CUP TO AVOID BARREL LEAKAGE OF AIR INTO THE PROTECTED LENGTH AREA. CLEARANCE DO NOT BLOCK VENT HOLES ON TOP OF CUP. A HOLE DIMENSION INSIDE SURFACE OF INSULATION, WALL, OR CEILING CEILING Fig. 2 COVER PLATE 3 5/16" DIA. PROTECTED (NON -CONDITIONED) AREA 051FG02A *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction; this will damage the sprinkler, the fitting, or both. Short inlet ("PL") versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet ("PL") should only be installed in CPVC fittings of wet -pipe systems. In all cases, verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal Obstruction No Internal Obstruction I I Female Female Pipe Pipe Thread Thread CPVC Fitting with Internal Obstruction CPVC fitting - No Internal Obstruction 1 Shorter Longer Inlet Inlet Male Male ae Pipe Pipe Thread Thread Dry Sprinkler Dry Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION COMDRYDET12 Fig. 3 5. Maintenance The Model G5-56 Dry should be inspected and the sprin- kler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Replace any sprinkler that has been painted (other than factory applied) or damaged in any way. Con- cealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinkler should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Engineering Specification Model G5-56 Dry Pendent Concealed Sprinkler Dry pendent sprinklers shall be dry pendent concealed sprin- klers with a flat cover plate. Sprinklers shall be cULus Listed as Quick Response for Light and Ordinary Hazard applications as well as FM Approved as Standard Response. Sprinklers shall be available in lengths from 4'/4 inches (108mm) to 48 inches (1219mm) in %-inch (6.35mm) increments based on face of fitting to finished ceiling distance. Sprinkler length shall be selected to provide the Exposed Minimum Barrel Length based on the minimum design temperature in the protected area and the minimum temperature in the conditioned space where the barrel is located in accordance with the Manufac- turer's written installation instructions. Sprinklers shall have [1-inch NPT][ISO 7-1 R1] threaded inlet fittings with [standard length inlets designed for use with wet- or dry -pipe sprinkler systems][short length inlets designed for use with wet -pipe sprinkler systems having pipe fittings with internal obstruc- tions that prevent the insertion of standard length inlets]. Sprinklers shall have a PTFE coated beryllium nickel Belleville spring washer inlet seal and brass alloy cap that prevent water entry from the sprinkler system piping into the sprinkler prior to actuation. Sprinklers shall have a fast -response fusible link that controls the movement of the inlet seal and cap through a mechanism consisting of link arms, a seat adapter, an ori- fice adapter, an inner tube, and a yoke. Sprinklers shall use a drop down deflector supported by tapered pins. Sprinklers shall have a galvanized steel cup for threaded attachment of the flat cover plate assembly. Cover plate attachment shall provide up to 1/2-inch (13mm) of adjustment. Sprinklers shall be [Ordinary temperature classification, 165°F (74°C), with 1350F temperature rated cover plates][Intermediate tempera- ture classification, 212°F, with 1650F temperature rated cover plates]. Cover plates shall be [solid][perforated] with factory applied [White] [Chrome] [Special Application — Specify] finish. Dry pendent concealed sprinklers shall be Reliable Model G5- 56 Dry (SIN RA5114). Ordering Information Specify: 1. Sprinkler: Model G5-56 Dry 2. Threads: [1-inch NPT - standard][ISO 7/1 R1 - optional] 3. Inlet Length: [Standard][Short ("PU)— for existing wet - pipe installations only] 4. Cover Plate Finish: [White] [Chrome] [Special Application — Specify] 5. Sprinkler/Cover Plate Temperature Rating: [Ordinary — 165°F sprinkler with 135°F cover plate] [I ntermed iate — 212°F sprinkler with 1657 cover plate] 6. Nominal Sprinkler Length (face of fitting to face of ceiling - "A' Dimension from Fig. 1): [Specify length — Lengths available from 4'/4 inches to 48 inches (108mm to 1219mm) in'/4-inch (6.35mm) increments] MATERIAL SPECIFICATIONS ITEM # DESCRIPTION MATERIAL 1 BODY, MACH. DZR BRASS 2 DEFLECTOR COPPER ALLOY 3 DEFL. SPUTTER BRASS ALLOY 4 DEFL. PIN STAINLESS STEEL 5 MEGA -INLET DZR BRASS 6 LINK ASSY. NICKEL/BERYLLIUM NICKEL 7 LEVER COPPER ALLOY 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY 10 FLIP DISK BRASS ALLOY 11 CAP BRASS ALLOY 12 WASHER PTFE COATED BERYLLIUM NICKEL 13 SETSCREW STAINLESS OR ALLOY STEEL 14 LOAD SCREW STAINLESS STEEL 15 BOTTOM CUP GALVANIZED STEEL 16 TOP CUP GALVANIZED STEEL 17 ADJ. SEAT ADAPTER BRASS ALLOY 18 YOKE BRASS ALLOY 19 CLOSURE YOKE BRASS ALLOY 20 ORIFICE ADAPTER BRASS ALLOY (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) 051 FG04 Fig. 4 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ®Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 02/21 P/N 9999970480 4. Miscellaneous Hanging Components OTOLCO' a brand of NIBCO' li Fig. 24 Hanger For CPVC Plastic Pipe G Double Fastener Strap Type - Side Mount Size Range — 3/4 thru 2 inch CPVC pipe. Material — Carbon Steel, Pre -Galvanized. Function — Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (WL) to support fire sprinkler piping. Meets and exceeds the requirements of N.F.P.A. 13, 13R, and 13D. Features — Figure 24 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two hex head self threading screws** furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre drilling of a pilot hole in wood is required. Finish— Pre-G a Ivan i ze d . Order By— Figure number and CPVC pipe size. * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Revision 5/24/2001 CPVC A B C Max. Hanger Fastener Hex Approx. Pipe Size Spacing (Ft.) Head Size Wt./100 3/4 2-5/16 1-5/32 1-3/16 5-1/2 5/16 9 1 2-5/8 1-5/16 1-3/16 6 5/16 9 1-1/4 3 1-1/2 1-3/16 6-1/2 5/16 11 1-1/2 3-1/4 1-5/8 1-3/16 7 5/16 12 2 3-11/16 1-27/32 1-3/16 8 5/16 15 ® Main Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92870 • Ph: 909.737.5599 • Fax: 909.737.0330 Distribution Center • 8790 Fruitridge Road • Sacramento, CA 95826 • Ph: 916.388.7800 • Fax: 916.388.1401 Manufacturing Facility • 4851 Homestead Road, Bldg. 118 • Houston, TX 77028 • Ph: 713.672.0058 • Fax: 713.672.0074 www.tolco.com Pipe Clamps M -5 m 0 iv 3 N Fig. 28 - "Stand -Off" Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe ** TOE= Size Range: — 3/4" (20mm) through 2" (50mm) Material: — Steel, Pre -Galvanized Function: — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off' design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. • The "Stand -Off' design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attaches easily to wood structure with two hex head self -threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16" (7.9mm) extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge (1.024mm) with (2) 1/4" x 1" tek type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals: — Underwriters Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8" (9.5mm) composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by: — Figure number and pipe size. Pat. # 7,455,268, Pat. # 7,832,248 ** With reduced spacing, consult factory. Fig. 27B (1) Required High Side of Hanger ApplicationLi Hanger Application Fig. 27B (2) Required it t4 Hanger and Restraint Application V r Pipe Size A B C Max Hanger Approx. Spacing Wt./100 Part No. in. (nun) in. (mm) in. (mm) in. (nun) Ft. (m) Ibs. (kg) 28-3/4 3/4" (20) 31/32" (77.0) 7" (50.8) 31/2' (88.9) 51/2 (1.67) 18 (8.1) 28-1 V (25) 35/16" (84.1) 23/16" (55.6) 31/2" (88.9) 6 (1.83) 21 (9.5) 28-11/4 11/4' (32) 35/8" (92.1) 23/8" (60.3) 31/2" (88.9) 61/2 (1.98) 23 (10.4) 28-11/2 11/2" (40) 4" (101.6) 21/2" (63.5) 31/2" (88.9) 7 (2.13) 31 (14.0) 28-2 2" (50) 41/2" (114.3) 211/16" (68.3) 35/8" (92.1) 8 (2.44) 34 (15.4) ce us LISTED 9--Li e by Fj-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 40 Fire Protection Solutions CPVC Clamps TOLCOT' Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe Size Range: Available in 3/4' (20mm) and 1" (25mm) pipe sizes Material: Pre -Galvanized Steel Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2" (20mm) x 11/2" (20mm) from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1 " hex head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre -Galvanized Order By: Figure number and pipe size. Patent Pending CPVC Max Hanger Approx. Pipe size Spacing W000 Part No. in. (nun) R. (m) lbs. (kg) 29-3/4 3/4" (20) 5'-6- (1.67) 18 (8.1) 29-1 1" (25) 6'-0" (1.83) 19 (8.6) Reduced Spacing For IPS Pipe IPS Max. Hanger Pipe Size Spacing Part No. in. (mm) Ft. (m) 29-3/4 3/4' (20) V-9" (1.67) 29-1 1" (25) V-10" (1.83) ®.0 m l Double Offset V 0 Single Offset (38.1mm) O cc, 0 0 Ee c(9us LISTED Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self -tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 40 B-Line series Fire Protection Solutions 5. Riser and Back Flow Model 8000/8011 RESIDENTIAL RISERPACK TM Pre -Assembled TESTANDRAIN° Riser Sizes: 1 " 11/a" 11/z" 211 The AGF RESIDENTIAL RIsERPACKTM Model 8000/8011 is a prepackaged economical riser assembly designed for NFPA 13D and 13R residential fire sprinkler systems. The one-piece casting provides required NFPA signage on both sides allowing for left or right installation and are available with grooved, threaded, or thread x groove ends. Threaded ends allow for easy connection to metal or plastic piping systems and grooved ends use approved rubber gasket couplings for secure connections. • Complies with NFPA requiements regarding testing through a properly sized test orifice • 1 " Models are available to meet nominal K-factor requirements of 2.8 to 5.6 • 1 " 8000 Models utilize a 3/a" ball valve with patented TESTANDRAIN® orifice specific outlet designed to accept either a standard garden hose or hard piped drain line • 11/a", 11/2", and 2" Models are available with orifices to meet K-factors of 2.8 to 11.2 • 11/a", 11/2", and 2" 8000 Models utilize a UL Listed/FM Approved Model 3011 BV INSPECTOR'sTESTT" ball valve • Cast and machined bronze made in the U.S.A. • Includes UL Listed/FM Approved AGF Model 7500 Pressure Gauge (300 PSI); 13R Models also include Model 7600 3-Way Globe Valve • Available as the Model 8011 with UL Listed/FM Approved Model 7000 Pressure Relief Valve (11/a"-2") or Model 7200 Pressure Relief Valve (1 ") designed to provide relief, test, and drain through a single valve %11 7/s" 1/2" 17/s2", and W (ELO) orifice sizes • Larger size risers are available on special order NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. SS-M8000M8011N002 • 01/15 TESTANDRAIN® and REMOTETESTO are registered trademarks of AGF Manufacturing Inc. 1 " Model 8000 LJIIIICII,IVI1, 1 " Model 8011 Model SIZE A B C D 1 101/2" 121/4" 43/4 ' 61/4" (267 mm) (311 mm) (121 mm) (159 mm) 0 1 1 4 11 " 121/4" ** 4" 61/2" 00 (279 mm) (311 mm) (102 mm) (165 mm) 0 1 /2" 12" 121/2" ** I 41/8' 65/8" (305 mm) (317 mm) (105 mm) (168 mm) 2" 12" 13" 43/8" 67/8" (305 mm) (329 mm) (111 mm) (174 mm) 1 101/2" 121/4" 27/8" *** 61/4" (267 mm) (317 mm) (73 mm) (159 mm) 11/4" 143/4" 15" 4" 61/2" 0 ao (375 mm) (381 mm) (102 mm) (165 mm) 1 /2 151/4" 151/4" 41/8" 65/8" (387 mm) (387 mm) (105 mm) (168 mm) 2" 151/4" 153/4" 43/8" 67/8" (387 mm) (399 mm) 1 (111 mm) (174 mm) *Additional space may be necessary to allow for hard drain fitting if required **Valve handle clearance required - add 2" ***Lift handle clearance required - add 31/8" n �1n MADE IN U.S.A. AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Model 8000/8011 RESIDENTIAL RISERPACKTM 11/4"-2" Model 8000 11/4"-2" Model 8011 VVIIINVIICIIL, Item No. Part Oty. 1 RiserPACK - Bronze Casting 1 2 3/4" Male x Female Ball Valve 1 3 1 " M3011 BV INSPEcroR'sTEST Valve 1 4 M7500 Pressure Gauge (1/4" 3-Way Globe Valve Included for 1313 Systems Only) 1 5 Water Flow Alarm Switch 1 3/4" MNPT x 1/2" FNPT Hose Adaptor Orifice 1 7 M7200 3/4" Pressure Relief Valve 1 8 M7000'/2" Pressure Relief Valve 1 9 1 " Brass Nipple 1 10 1 " Brass Street Elbow 1 11 �/2" Brass System Access Port Plug 1 12 1 " Relief Valve Bypass Nipple 1 13 1 " Relief Valve Bypass Tee 1 14 1/2" NPT x-Barb Straight Fitting 1 15 '/2" NPT x-Barb Elbow Fitting 1 16 Clamps 2 17 Nylobraid Relief Valve Drain Tubing 1 Job Name: Architect: Engineer: Contractor: ES-A-2000B Job Name Job Location Engineer — Approval — Series 2000B Double Check Valve Assemblies Sizes:'/2" - 2" (15 - 5Omm) g/4" 2000B (20mm) !a q Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • '/2" - 2" (15 - 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • '/2" - 1 " (15 - 25 mm) have tee handles It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material prod- uct, consult your local water authority, building and plumbing codes. Contractor Approval Contractor's P.O. No. Representative 2" 2000B HC (50mm) Series 2000E Double Check Valve Assemblies are designed to protect drinking water supplies for dangerous cross -connections in accordance with national plumbing codes and water authority requirements for non -health -hazard non - potable service applications such as irrigation, fire line, or industrial processing. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B. The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety informa- tion before beginning the installation of this product. Ames Fire & Waterworks product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Ames Fire & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire & Waterworks products previously or subsequently sold. A WATTS Brand Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 21/2" inlet/outlet fire hydrant fitting (2" valve) Pressure — Temperature Temperature Range: 33°F — 140°F (0.5°C — 60°C) Maximum Working Pressure: 175psi (12.1 bar) Dimensions - Weights Standards AWWA Std. C510, IAPMO PS31 ,!Site Approvals G CP ®oC U� uS us 1015 B64.5 3/4" - 2" (LBV Models Only) • Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. (Excluding all LBV Models) • Horizontal and vertical "flow up" approval on all sizes. Suffix HC — Fire Hydrant Fittings dimension "A" = 231/2" (594mm) i 10 G 10 SIZE (ON) DIMENSIONS WEIGHT in. mm in. A mm B in. mm in. C mm in. F mm G in. mm H in. mm I in. mm lbs. kgs. 1/2 15 10 254 46/a 117 2'/6 62 5 127 3% 85 26/6 59 21/16 52 4.5 2 3/4 20 111/6 282 4 102 31/6 79 63/16 157 3'/6 87 21/8 54 16/6 33 5 2.3 1 25 131/4 337 51/8 130 4 102 71/2 191 33/8 85 111/16 43 111/16 43 12 5.4 11/4 32 16% 416 5 127 36/6 84 91/2 241 5 127 3 76 2 50 15 6.8 11/2 40 163/4 425 4'/8 124 31/2 89 93/4 248 513/16 148 31/8 79 211/16 68 15.86 7.2 2 50 191/2 495 1 61/4 159 4 102 1 133/s 340 1 61/6 156 1 37/ 6 87 1 211/16 68 1 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California lab tests. ATypical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 112" (15mm) y 83 12 0 69 10 55 8 3 41 6 N 28 4 (D 14 2 (L 0 0 0 2 4 6 8 10 12 gpm OP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Flow Rate kPa psi y 152 22 J 124 18 i 96 14 7 y 69 10 a 41 6 14 2 n 314" (20mm) OP 0 5 10 15 26 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 Ipm 7.5 15 fps 2.3 4.6 mps Flow Rate kPa psi a 1114" (32mm) 96 14 N 83 12 o 69 10 y 55 8 3 41 6 y 28 4 a 14 2 0 0 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi 111211 (40mm) 83 12 y 69 10 0 55 8 y 41 6 28 4 fyil 14 2 0 0 L pp0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate N N kPa psi 1 " (25mm) N J N 110 16 o 0 83 12 i y 69 10 H 55 8 y 41 6 14 28 4 a i a 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm AP 0 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate A WATTS Brand ES-A-200013 1735 kPa psi " (50mm) 83 12 Q 69 10 55 8 41 6 28 4 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm AP 0 95 190 285 380 475 570 665 760 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate USA: Backflow T: (978) 689-6066 • F: (978) 975-8350 • AmesFireWater.com USA: Control Valves T: (713) 943-0688 • F: (713) 944-9445 • AmesFireWater.com Canada: T: (905) 332-4090 • F: (905) 332-7068 • AmesFireWater.ca Latin America: T: (52) 81-1001-8600 • AmesFireWater.com © 2017 Ames Fire & Waterworks