BLD2023-0073_Site_Plan_1.18.2023_8.35.40_AM_3319795Prop
Line
9k
Untitled Map
Write a description for your map.
Legend
20625 Maplewood Dr
kip
4 a
r �
i
it
00
10
•
41 , .
UK �
Job Name:
Tag# F"DA,1K,1N
Submittal Data Sheet 3MXL24RMVJU
3 Port, 2-Ton Outdoor Heat Pump
41K/N
F >
``t r,,�,
l IFF'r.
Complete warranty details available from your local dealer or at
www.daikincomfort.com. To receive the 12-Year Parts Limited
Warranty, online registration must be completed within 60 days of
installation. Online registration is not required in California or Quebec.
If product is installed in a commercial application, limited warranty
period is 5 years.
Outdoor Specifications I
Compressor
Hermetically Sealed Swing Type
Refrigerant
R-410A
Factory Charge (Lbs)
6.17
Refrigerant Oil
PVE (FVC50K)
Airflow Rate (cfm)
Cooling
eating
H
2,094
H
1,886
M
2,094
M
1,780
L
1,006
Sound Pressure Level (dBA)
52 / 54
mensions (H x W x D) (in)
28-15/16 x 34
12-5/8
VVU1g11L kLUbJ
140
Efficiency
SEER
EER
HSPF
COP
Non -Ducted
18
12.7
12.5
3.41
Ducted
14
9.9
8.2
3.26
Mixed
15.95
11.3
10.35
3.33
Performance
Cooling (Btu/hr)
Rated (Min/Max)
24,000
Operating Range
147 —115`F
Rated Cooling Conditions: Indoor: 80°F DB/67°F WB
Outdoor: 957 DB/75°F WB
Heating (Btu/hr)
Rated
24,000
Operating Range
-13°F — 607
Rated Heating Conditions: Indoor: 70°F DB/60°F WB
Outdoor: 477 DB/43°F WB
Electrical
208/60/1
230/60/1
System MCA
22.6
22.6
System MFA
25
25
Compressor RLA
17.5
17.5
Outdoor fan motor FLA
.42
.42
Outdoor fan motor W
122
122
MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A)
RLA: Rated load amps (A) W: Fan motor rated output (W)
Piping
Liquid (in)
Y. x 3
Gas (in)
3/8 x 1,
%x2
Drain (in)
5/8
Max. System Piping Length (ft)
230
Max. Interunit Piping Length (ft)
82
Max. Height Difference — IDU to ODU (ft)
49.25
Max. Height Difference —IDU to IDU (ft)
24.625
Chargeless (ft)
131.2
Additional Charge of Refrigerant (oz/ft)
.21
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date: May 2018 Page 1 of 7
N
0
m
O
E
G
ry
N
J
X
�M
I
HANDLE 9/16 (14) 34-1/4 (870) 3-9/16 (90)
1/4 (7) 12-5/8 (320) 1-3/16 (30)
BRAND NAME PLATE
MANUFACTURER'S
LABEL
C
m
OD
N
4-HOLES FOR FOUNDATION BOLTS
51160 R 318 (M8 OR Ml0) 23-5/8 (600) 4-15/16 (125)
Co
A 'B
20-11/16 (525)
DRAIN OUTLET
(I.D 018 (015.9) HOSE FOR CONNECTION
WITH DRAIN JOINT)
`A,"B DRAIN OUTLET
WHEN CONDUCTING CONCENTRATEif,
DRAIN PIPING WORK, ATTACH THE
SUPPLIED DRAIN CAPS.
4-GROUND TERMINALS
LIQUID Q1/4 6.4) 2-9116 65
�3l8 ¢9.5 3-11/16 93
GAS o1l2 �12.7) 3-5/16 84
e
A CD
m
N m
N
m
C6
IN CASE OF REMOVING STOP VALVE 1-11/16 (43) Ill 11/16
COVER AND TERMINAL STRIP COVER
9/16 (14.5) UL. 6 v 3-1/16
13-5/8 (346) 11 7/16 (11) m
STALLATION LEG
PITCH)
14-1/2 (368) MINIMUM SPACE FOR AIR PASSAGE
<ROOM A> WALL HEIGHT ON AIR OUTLET SIDE=LESS THAN 47-1/4 (1200)
GAS PIPE i
/(W8 (69.5) SINGLE UNION)
LIQUID PIPE 4
/(�1/4 ((6.4) SINGLE UNION) o
<ROOM B> o
GAS PIPE a
/(�1/2 (012.7) SINGLE UNION) �, 1-15/16 (50)
LIQUID PIPE 1-15/16 (50) M
/(01/4 (06.4) SINGLE UNION) ci
<ROOM C>
GAS PIPE
(0112 (012.7) SINGLE UNION)
LIQUID PIPE
/(�1/4 (06.4) SINGLE UNION) o
o
Co 0
in co
n 4 Cl) 7Lo
Lo :z c 1-15/16 (50) M c°
7 N 7
N v a0
M
UNIT: inch (mm)
3DO93198A
0
N
000
a
Job Name:
Tag#
DAiqKAqN
Submittal Data Sheet 5MXS48TVJU
5 Port, 4-Ton Outdoor Heat Pump
A
A
i I JJ-rro
Complete warranty details available from your local dealer or at
www.daikincomfort.com. To receive the 12-Year Parts Limited
Warranty, online registration must be completed within 60 days of
installation. Online registration is not required in California or Quebec.
If product is installed in a commercial application, limited warranty
period is 5 years.
Outdoor Specifications
Compressor
Hermetically Sealed Swing Type
Refrigerant
R-410A
Factory Charge (Lbs)
8.60
Refrigerant Oil
PVE (FVC50K)
Airflow Rate (cfm)
Cooling
Heating
H
3,684
H
3,356
M
3,029
M
3,138
L
1,500
Sound Power Level (dBA)
52 / 55
Dimensi
- 16 x 18-1/8
Weight (Lbs)
216
Efficiency
SEER
EER
HSPF
COP
Non -Ducted
20.2
10.5
11.1
3.9
Ducted
15.3
8.6
8.6
3.2
Mixed
17.75
9.55
9.85
3.5
Performance
Cooling (Btu/hr)
Rated
47,000
Operating Range
147 —115°F
Rated Cooling Conditions: Indoor: 80°F DB/67°F WB
Outdoor: 957 DB/75°F WB
Heating (Btu/hr)
Rated
48,500
Operating Range
57 — 60°F
Rated Heating Conditions: Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
Electrical
208/60/1
230/60/1
System MCA
33.2
33.2
System MFA
35
35
Compressor RLA
27
27
Outdoor fan motor FLA
1.15
1.15
Outdoor fan motor W
84
84
MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A)
RLA: Rated load amps (A) W: Fan motor rated output (W)
Piping
Liquid (in)
% x 5
Gas (in)
3/8 x 1,
%: x 2,
5/8 x 2
Drain (in)
1
Max. System Piping Length (ft)
262
Max. Interunit Piping Length (ft)
98
Max. Height Difference — IDU to ODU (ft)
49.25
Max. Height Difference —IDU to IDU (ft)
24.625
Chargeless (ft)
131.6
Additional Charge of Refrigerant (oz/ft)
.21
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date: May 2019 Page 1 of 12
&% w RAWRAW
5MXS48TVJU Dimensional Data A&VAMEAMNEW
CD
9
a-ia ietr>E,:
�1
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date: May 2019 Page 2 of 12