BLD2023-0076_Manufacturer_Specifications_and_Installation_Instructions_1.18.2023_3.44.32_PM_3321400
HEAT PUMP OUTDOOR UNITS LENNOX RES/DENT/AL PROD UC T SPEC/FICA TONS ELITE @ SERIES LENNOX QUANTUM" COIL MODEL NUMBER IDENTIFICATION EL17XP1 ; ; ; ; Product Tier ------- EL = Elite® Series No"17SEER2 2------- 1 Refrigerant Type ------ X = R-410A Unit Type ---- ; P = Heat Pump Outdoor Unit ; Cooling Stages --- 1 = Single Stage Compressor EL17XP1 ELITE° Series R-410A - 60 Hz Bulletin No. 211008 September 2022 Supersedes August 2022 P r SEER up to 17.00 / SEER2 up to 16.00 HSPF up to 9.50 / HSPF2 up to 8.50 1.5 to 5 Tons Cooling Capacity - 18,000 to 56,500 Btuh Heating Capacity - 16,500 to 54,000 Btuh -036-230A01 Revision Number Ratings Revision Letter •--- Voltage 230 = 208/23OV-1 ph-60Hz Nominal Cooling Capacity 018 = 1-1/2 tons 024 = 2 tons 030 = 2-1/2 tons 036 = 3 tons 042 = 3-1/2 tons 048 = 4 tons 060 = 5 tons FEATURE HIGHLIGHTS u CONTENTS 1. Outdoor Coil Fan 2. Quantum" Coil 3. High Pressure Switch 4. Low Pressure Switch 5. Expansion Valve - Outdoor Unit 6. Four -Way Reversing Valve 7. Hi -Capacity Liquid Line Drier 8. Scroll Compressor 9. Compressor Sound Dampening System 10. Defrost Control 11. Heavy Gauge Steel Cabinet 12. SmartHinge'" Louvered Coil Protection 13. Refrigerant Line Connections Approvals And Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Dimensions........................................................10 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Features...........................................................3 Field Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Installation Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Model Number Identification................................................1 Optional Accessories - Order Separately . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 SoundData.........................................................9 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 TXV Substitution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 TXVUsage.........................................................11 EL17XP1 - 2 to 5 Ton Heat Pump / Page 2 APPROVALS AND WARRANTY r"I U U MIT111IM • AHRI Certified to AHRI Standard 210/240-2023 • For AHRI Certified system match -ups and expanded ratings, visit www.LennoxPros.com • ENERGY STAR° certified • Sound rated to AHRI Standard 270-2008 test conditions • Tested in the Lennox Research Laboratory environmental test room • Rated according to U.S. Department of Energy (DOE) test procedures • Units and components UL, NEC, and CEC bonded for grounding to meet safety standards for servicing • ETL certified (U.S. and Canada) • ISO 9001 Registered Manufacturing Quality System WARRANTY • Compressor: • Limited ten years in residential installations • Limited five years in non-residential installations • All other covered components: • Limited five years in residential installations • Limited one year in non-residential installations NOTE - Refer to Lennox° Basic Limited Warranty at www.Lennox.com for additional details. FEATURES APPLICATIONS • 1.5 through 5 tons • Sound levels as low as 71 dBA • Single phase power supply • Vertical air discharge • Applicable to indoor air handlers or gas furnaces with indoor add -on coils • Shipped completely factory assembled, piped and wired • Factory test operated NOTE - When heat pumps are used with gas furnaces, a dual -fuel compatible thermostat or a zone control system with dual -fuel capabilities must be used (order separately) NOTE - Installer must set outdoor unit, connect refrigerant lines and make electrical connections to complete job REFRIGERATION SYSTEM R-410A Refrigerant • Non -chlorine, ozone friendly • Unit is factory pre -charged NOTE -Total system refrigerant charge is dependent on outdoor unit size, indoor unit size and refrigerant line length NOTE - Refer to the unit -mounted charging sticker to determine correct amount of charge required OOutdoor Coil Fan • Direct drive fan • Vertical air discharge • Totally enclosed fan motor • PSC motor (018, 024, 030 and 036 models) • ECM motor (042, 048 and 060 models) • Inherently protected • Fan guard constructed of corrosion -resistant PVC (polyvinyl chloride) coated steel © QuantumTM Coil • Lennox designed and fabricated coil • Enhanced aluminum alloy tube/enhanced fin coil • Ripple -edged aluminum fins • Aluminum tube construction • Lanced fins for maximum fin surface exposure • Fin collars grip tubing for maximum contact area • Flared shoulder tubing connections • Factory tested under high pressure • Entire coil is accessible for cleaning © High Pressure Switch • Protects the system from high pressure conditions that can be a result of fan failure or a blocked/dirty coil • Automatic reset ® Low Pressure Switch • Shuts off unit if suction pressure falls below setting • Provides loss of charge and freeze-up protection • Automatic reset EL17XP1 - 1.5 to 5 Ton Heat Pump / Page 3 FEATURES REFRIGERATION SYSTEM (continued) © Expansion Valve - Outdoor Unit • Designed and sized for heat pump systems • Sensing bulb senses evaporator suction temperature during heating cycle OFour -Way Reversing Valve • Rapid changeover of refrigerant flow direction from cooling to heating and vice versa • Operates on pressure differential between outdoor unit and indoor unit of the system • Factory installed © High -Capacity Liquid Line Drier • Factory installed in the liquid line • Drier traps moisture or dirt • 100% molecular -sieve, bead type, bi-flow drier Optional Accessories Check/Expansion Valve Kits • Field installed on certain indoor units • See TXV Usage table • Chatleff style fitting Freezestat • Installs on or near the vapor line of the indoor coil or on the suction line • Senses suction line temperature • Cycles compressor off when suction line temperature falls below it's setpoint • Opens at 29°F and closes at 58°F • Installs on or near the discharge line of the evaporator or on the suction line Refrigerant Line Kits • Refrigerant lines are shipped refrigeration clean. • Lines are cleaned, dried, pressurized and sealed at factory • Suction line fully insulated • Lines are stubbed at both ends NOTE - Not available for -060 models and must be field fabricated COMPRESSOR Scroll Compressor • High efficiency with uniform suction flow • Constant discharge flow, high volumetric efficiency and quiet operation • Low gas pulses during compression reduces operational sound levels • Compressor motor is internally protected from excessive current and temperature • Compressor is installed in the unit on resilient rubber mounts for vibration free operation Scroll Compressor Operation • Two involute spiral scrolls matched together generate a series of crescent -shaped gas pockets between them • During compression, one scroll remains stationary while the other scroll orbits around it • Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates • As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced • When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls • During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle • Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency • Compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged Crankcase Heater (036-042-048-060 models) • Protects against refrigerant migration that can occur during low ambient operation OCompressor Sound Dampening System • Polyethylene compressor cover • 2-inch thick batt of fiberglass insulation • Hook and loop fastening tape on all open edges Optional Accessories Compressor Crankcase Heater (018-024-030 models) • Protects against refrigerant migration that can occur during low ambient operation EL17XP1 - 2 to 5 Ton Heat Pump / Page 4 FEATURES CONTROLS Defrost Control • Time/temperature defrost control is furnished as standard equipment • Control initiates a defrost cycle every 30, 60 or 90 minutes of compressor "on" time at outdoor coil temperatures below 42°F • Factory setting is 90 minutes • Anti -short cycle, timed -off control (5 minutes) • Compressor delay (30 seconds, field selectable) for cycling the compressor in and out of the defrost mode • High and low pressure switch monitoring with five -trip lockout • Two diagnostic LEDs furnished as an aid in troubleshooting. • Conveniently located in control box Optional Accessories E30 Smart Wi-Fi Thermostat • Wi-Fi enabled, electronic 7-day, universal, multi -stage, programmable, touchscreen thermostat • 3 Heat/2 Cool • Auto -changeover • Controls dehumidification during cooling mode and humidification during heating mode • Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol° control, and equipment maintenance reminders • Easy to read 7 in. color touchscreen (measured diagonally) • LCD display with backlight shows the current and set temperature, time, inside relative humidity, system status (operating mode and schedules) and outside temperature (optional outdoor sensor required) • Smooth Setback Recovery starts system early to achieve setpoint at start of program period • Compressor short -cycle protection (5 minutes) • Up to four separate schedules are available plus Schedule IQ'" • One -Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away • Smart Away'" - Uses geo-fencing technology to determine when the homeowner is within a predetermined distance from the home to operate the system when leaving, away and arriving • Wi-Fi remote monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets • Smart home automation compatible with Apple HomeKitT", Amazon Alexa°, Google Assistant and IFTTT • Service Dashboard features online real-time monitoring of installed Lennox° smart thermostats • High Definition Color Display with Subbase, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation NOTE - See the Lennox® E30 Smart Wi-Fi Thermostat Product Specifications bulletin for more information Remote Outdoor Temperature Sensor • Used with the Lennox° E30 Smart Thermostat • Outdoor sensor allows thermostat to display outdoor temperature y� • Sensor is auto -detected when connected to thermostat NOTE - Sensor is required for high and low balance points option. NOTE - Sensor is required for Enhanced Dehumidification Accessory (EDA) applications. Thermostat • Thermostat is not furnished with unit • See Lennox Price Book for selection Compressor Hard Start Kit • Single-phase units are equipped with a PSC compressor motor • This type of motor normally does not need a potential relay and start capacitor • In conditions such as low voltage, kit may be required to increase the compressor starting torque Compressor Low Ambient Cut -Off • Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35°F Indoor Blower Off Delay Relay • Delays the indoor blower -off time during the cooling cycle Low Ambient Kit • Heat pump in the cooling mode will operate satisfactorily down to 45°F outdoor air temperature without any additional controls • Allows unit to operate properly down to 30°F in the cooling mode NOTE - Crankcase heater (optional for-018-024-030 models) and freezestat should be installed on compressors equipped with a low ambient kit NOTE - A compressor lock -out thermostat should be added to terminate compressor operation below recommended operation conditions Mild Weather Kit • Heat pump units operate satisfactorily in the heating mode at outdoor air temperatures up to 75°F • Allows heating operation above 75°F Monitor Kit - Service Light • Ambient compensating thermistor • Service light thermostat • For thermostats requiring indicator light inputs EL17XP1 - 1.5 to 5 Ton Heat Pump / Page 5 FEATURES CONTROLS (continued) Optional Accessories (continued) Outdoor Thermostat Kit • Outdoor thermostat locks out some of the electric heating elements on indoor units where two -stage control is applicable • Outdoor thermostat maintains the heating load on the low power input as long as possible before allowing the full power load to come on the line • Thermostat kit and Mounting Box must be ordered separately 19 CABINET • Heavy -gauge steel construction • Pre -painted cabinet finish • Control box is conveniently located with all controls factory wired • Corner patch plate allows compressor access • Drainage holes are provided in base section • High density polyethylene unit support feet raise the unit off of the mounting surface PermaGuard'" Unit Base • Durable zinc -coated base section resists rust and corrosion All SmartHinge Louvered Coil Protection • Steel louvered panels provides complete coil protection • Panels are hinged to allow easy cleaning and servicing of coils • Panels may be completely removed • Interlocking tabs and slots assure tight fit on cabinet Refrigerant Line Connections, Electrical Inlets and Service Valves ®• Sweat connection vapor and liquid lines • Vapor valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system • Refrigerant line connections and field wiring inlets are located in one central area of the cabinet • See dimension drawing Optional Accessories Snow Guard • For use in locations where the possibility of heavy snow or freezing rain accumulation may occur • Heavy gauge powder coated steel guard • Deflects snow and ice away from the outdoor fan NOTE - Snow Guards for 018-024-030-036 models are only available in Canada. EL17XP1 - 2 to 5 Ton Heat Pump / Page 6 SPECIFICATIONS General Model No. Data Nominal Tonnage EL17XP1-018 EL17XP1-024 EL17XP1-030 EL17XP1-036 1.5 2 2.5 3 Connections Liquid line (o.d.) - in. (sweat) Suction line (o.d.) - in. 3/8 3/8 3/8 3/8 3/4 3/4 3/4 7/8 ' Refrigerant R-410A charge furnished 6 lbs. 2 oz. 6 lbs. 0 oz. 7 lbs. 5 oz. 8 lbs. 9 oz. Outdoor Net face area - sq. ft. Outer coil Coil Inner coil Tube diameter - in. No. of rows Fins per inch 24.5 24.5 18.7 22.2 - - - - - - 18.0 21.5 5/16 5/16 5/16 5/16 1 1 2 2 22 22 22 22 Outdoor Diameter - in. Fan No. of blades Motor hp Cfm Rpm Watts 22 22 22 26 2 2 2 3 1/8 1/8 1/6 1/5 2840 2840 2670 3590 825 825 825 825 127 127 162 200 Shipping Data - lbs. 1 pkg. 220 220 220 250 ELECTRICAL DATA Line voltage data - 60Hz 208/23OV-1 ph 208/23OV-1 ph 208/23OV-1 ph 208/23OV-1 ph 2 Maximum overcurrent protection (MOCP) amps 20 25 25 30 3 Minimum circuit ampacity (MCA) 13.6 15.1 15.6 17.8 Compressor Rated load amps Locked rotor amps 10.3 11.5 11.7 13.1 45.7 59.5 71.3 83.1 Outdoor Fan Motor Full load amps 0.7 0.7 1.0 1.4 CONTROLS - ORDER SEPARATELY E30 Smart Wi-Fi Thermostat 20A65 Remote Outdoor Temperature Sensor X2658 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 Compressor Hard Start Kit LG 88M91 Copeland 10J42 Compressor Low Ambient Cut -Off 45F08 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M81 ° Low Ambient Kit 54M89 Mild Weather Kit 1111397 Monitor Kit - Service Light 76F53 Outdoor Thermostat 1OZ23 Thermostat Kit Mounting Box 31461 Refrigerant L15-41-20 (20 ft.) 89J56 Line Sets L15-41-30 (30 ft.) 89J57 L 15-41-40 (40 ft.) 89J 58 L 15-41-50 (50 ft.) 89J 59 L15-65-30 (30 ft.) 89J60 L 15-65-40 (40 ft.) 89J 61 L15-65-50 (50 ft.) 89J62 SSnow Guard 35-1/2 x 31 in. (Canada Only) X8780 NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. ^ Crankcase Heater and Freezestat are recommended with Low Ambient Kit. e Adds 11-1/2 inches (292 mm) to unit height. EL17XP1 - 1.5 to 5 Ton Heat Pump / Page 7 SPECIFICATIONS General Model No. Data Nominal Tonnage EL17XP1-042 EL17XP1-048 EL17XP1-060 3.5 4 5 Connections Liquid line (o.d.) - in. (sweat) Suction line (o.d.) - in. 3/8 3/8 3/8 7/8 7/8 1-1/8 ' Refrigerant R-410A charge furnished 10 lbs. 2 oz. 9 lbs. 2 oz. 10 lbs. 4 oz. Outdoor Net face area - sq. ft. Outer coil Coil Inner coil Tube diameter - in. No. of rows Fins per inch 24.93 24.93 29.09 24.13 24.13 28.16 5/16 5/16 5/16 2 2 2 22 22 22 Outdoor Diameter - in. Fan No. of blades Motor hp Cfm Rpm Watts 26 26 26 3 3 3 1/3 1/3 1/3 4110 4110 4060 825 825 825 213 213 224 Shipping Data - lbs. 1 pkg. 285 285 300 ELECTRICAL DATA Line voltage data - 60Hz 208/23OV-1 ph 208/23OV-1 ph 208/230V-1 ph 2 Maximum overcurrent protection (MOCP) amps 40 50 50 3 Minimum circuit ampacity (MCA) 25.9 33.9 32.5 Compressor Rated load amps Locked rotor amps 18.6 25 23.9 110 120 124.5 Outdoor Fan Motor Full load amps 2.4 - 2.6 2.4 - 2.6 2.4 - 2.6 CONTROLS - ORDER SEPARATELY E30 Smart Wi-Fi Thermostat 20A65 Remote Outdoor Temperature Sensor X2658 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Hard Start Kit Copeland LG 1 OJ42 88M91 Compressor Low Ambient Cut -Off 45F08 Freezestat 3/8 in. tubing 5/8 in. tubing 93G35 5OA93 Indoor Blower Off Delay Relay 58M81 ° Low Ambient Kit 54M89 Mild Weather Kit 111397 Monitor Kit - Service Light 76F53 Outdoor Thermostat Kit Thermostat Mounting Box 1OZ23 31461 Refrigerant Line Sets L15-65-30 (30 ft.) 89J60 L15-65-40 (40 ft.) 89J61 L15-65-50 (50 ft.) 89,162 Field Fabricate 5 Snow Guard 39-1/2 X 35-5/8 in. Y1033 NOTE -Extremes of operating range are plus 10% and minus 5% of line voltage. Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. " Crankcase Heater and Freezestat are recommended with Low Ambient Kit. 'Adds 11-1/2 inches (292 mm) to unit height. EL17XP1 - 2 to 5 Ton Heat Pump / Page 8 SOUND DATA ' Model Octave Band Sound Power Levels dBA, re 10-12 Watts Center Frequency - HZ 1 Sound Rating Number (dBA) 2 Estimated Sound Pressure Level at Distance From Unit (dBA at distance in ft.) 125 250 500 1000 2000 4000 8000 3 5 10 15 50 018 56 58 64.5 62.5 61.5 55 49 71 64 59 53 50 39 024 55.5 58 63 63.5 59 55 51 71 64 59 53 50 39 030 60 60 65 67.5 64 57 49.5 71 64 59 53 50 39 036 62 61 66 66.5 63 57 48 72 65 60 54 51 40 042 55 60 66 66.5 63 57 50.5 72 65 60 54 51 40 048 56 61.5 67.5 68.5 63 56 50 73 66 61 55 52 41 060 57 64 68 67 65 60 56 73 66 61 55 52 41 NOTE - the octave sound power data does not include tonal correction. Tested according to AHRI Standard 270-2008 test conditions. 2 Estimated sound pressure level at distance based on AHRI Standard 275-2010 method for equipment located on the ground, roof, or on side of building wall with no adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 275. FIELD WIRING FDISCONNECTI SWITCH I I (By Others) I r — — J OPTIONAL I ELECTRIC /1 HEAT — j ---- F OPTIONAL I OUTDOOR I �THERMCL LENNOX INDOOR UNIT LENNOX OUTDOOR UNIT INSTALLATION CLEARANCES A - Two Wire Power (see Electrical Data) B - Two or Three Wire Power (size to heater capacity) F----I C - Twelve Wire Low Voltage 18 ga. minimum + DISCONNECT I Fourteen Wire Low Voltage with Optional Outdoor SWITCH g p (By Others) Thermostat r — — — — — I D - Eight Wire Low Voltage 18 ga. minimum THERMOSTAT, Ten Wire Low Voltage with Optional Outdoor Thermostat (Optional) NOTE - Field Wiring Not Furnished r1 All wiring must conform to NEC or CEC and local `J electrical codes. NOTE - Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (914 mm) Clearance to one of the remaining two sides may be 12 in. (305 mm ) and the final side may be 6 in. (152 mm). A clearance of 24 in. (610 mm) must be maintained between two units. 48 in. (1219 mm) clearance required on top of unit. See NOTES T Control See NOTES Box EL17XP1 - 1.5 to 5 Ton Heat Pump / Page 9 DIMENSIONS r TOP VIEW C DISCHARGE AIR* SIDE VIEW UNIT SUPPORT FEET \ VAPOR LINE CONNECTION LIQUID LINE CONNECTION LIQUID LINE CONNECTION ELECTRICAL INLETS VAPOR LINE CONNECTION 4-3/4 4-1/4(108) (121) 172) Q 0 20-5/8 (524) on 7-3/4 (197) 4-1/2 (114) 3-1/4 27-1/8 3 5/8 (83) (689) (92) EL17XP1-018 TO -030 BASE SECTION (Medium Base) 1 (25) END VIEW UNIT SUPPORT FEET 16-7/8 (429) 26-7/8 (683) 8-3/4 (222) 3-3/4 (95) 3-1/8 30-3/4 (781) 4-5/8 (79) (117) EL17XP1-036 TO -060 BASE SECTION (Large Base) Model A (Height) in. mm B (Width) in. mm C (Depth) in. mm 018 45 1143 30-1/2 775 35 889 024 45 1143 30-1/2 775 35 889 030 35 889 30-1/2 775 35 889 036 35 889 35-1/2 902 39-1/2 1003 042 39 991 35-1/2 902 39-1/2 1003 048 39 991 35-1/2 902 39-1/2 1003 060 45 1143 35-1/2 902 39-1/2 1003 EL17XP1 - 2 to 5 Ton Heat Pump / Page 10 TXV USAGE Use this table for C35, CH23 and CR33 Field Installed TXV Match -Ups Model I Order No. 018 I12J18 024 I12J18 030 I12J18 036 I12J19 042 I12J20 048 I12J20 060 I12J20 CX35 and CHX35 coils and all Lennox air handlers are shipped with a factory installed TXV. C35 coils - Replace the factory installed RFC orifice with the expansion valve listed. CR33 and CH23 - Use the expansion valve listed. AHRI STANDARD 210/240-2023 Standard Ratings relating to cooling or heating capacities shall be net values, including the effects of circulating -fan heat, but not including supplementary electric heat. Power input used for calculating efficiency shall be the Total Power. Standard Ratings of units which do not have indoor air - circulating fans furnished as part of the model, i.e., Coil - only System, shall be established by subtracting from the total cooling capacity 1,505 Btu/h per 1,000 SCFM, and by adding the same amount to the heating capacity for non - mobile -home, non -Space Constrained units. Total Power for both heating and cooling shall be increased by 441 W per 1,000 SCFM of indoor air circulated. TXV SUBSTITUTION A general guide for replacing the factory installed TXV if the indoor unit (coil/air handler) is larger or smaller than the outdoor unit. Outdoor Unit Indoor Unit TXV Furnished TXV Replacement Size Tons Size Tons 018 1.5 30/36 2.5/3 12J19 12J18 018 1.5 36 3 12J19 12,118 018 1.5 42 3.5 12J20 12J18 018 1.5 48 4 12.120 12J18 018 1.5 49 4 12J20 12J18 018 1.5 50/60 4/5 12J20 12J18 018 1.5 51/61 4/5 12J20 12J18 018 1.5 60 5 12J20 12J18 024 2 42 3.5 12J20 12J18 024 2 48 4 12J20 12J18 024 2 49 4 12J20 12J18 024 2 50/60 5 12.120 12J18 024 2 51/61 5 12.120 12J18 024 2 60 5 12.120 12J18 030 2.5 42 3.5 12.120 12.118 030 2.5 43 3.5 12.120 12J18 030 2.5 48 4 12J20 12J18 030 2.5 49 4 12J20 12J18 036 3 24 2 12J18 12J19 036 3 30 2.5 12J18 12J19 042 3.5 24 2 12,118 12J20 042 3.5 30 2.5 12J18 12.120 042 3.5 30/36 3 12J19 12.120 042 3.5 36 3 12J19 12.120 048 4 30/36 2.5/3 12J19 12.120 048 4 36 3 12J19 12.120 TXV Ranges: 12J18 - 1.5 to 2.5 ton systems - Use on 2.5 ton (030) and lower systems. 12J19 - 3 ton systems - Use down to 2 ton (024) systems. 12J20 - 3.5 to 5 ton systems - Use down to 3 ton (036) systems. EL17XP1 - 1.5 to 5 Ton Heat Pump / Page 11 REVISIONS Sections Dimensions TXV Usage LE--7 NNOX Description of Change Corrected EL17XP1-036 height. Removed CH35 coils (product discontinued). AA **HH" MEMBER COMPANY O(T CUS STE ntertek Visit us at www.Lennox.com For the latest technical information, www.LennoxPros.com Contact us at 1-800-9-LENNOX NOTE - Due to Lennox' ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2022 Lennox Industries, Inc.