Compliance reportLONGITUDE
ONE TWENTY°
ENGINEERING & DESIGN
Helical Pile Review for Structural Compliance
Date: March 22, 2022
Project Name: 9423 232nd St SW - Foundation Stabilization Effort L120 Project #S210728-7XR
Project Location: 9423 232nd St SW, Edmonds, WA 98020
Client's Name: Barbara Stasiak, Project Coordinator — R&R Foundation Specialist, LLC
To whom it may concern,
The purpose of this letter is to confirm helical pile installation and capacity compliance with the structural
requirements specified in the L120 Structural Calculation Package and Structural Site & Foundation Plan dated
August 9, 2021.
On March 2, 2022, five (5) helical piles were installed by R&R Foundation Specialists (R&R) to lift and stabilize the
residence located at 9423 232nd St SW, Edmonds, WA. Piles were installed with a DIGGA 10k drive head to a
maximum depth of 7 ft. To the knowledge of L120, these piles were installed by R&R certified installers in
accordance with the cited structural package and ESR-3750. Please refer to the attached drive log provided by
R&R.
With pile spacing at a maximum of 8'-0" on -center at the exterior, the minimum required vertical capacity as
determined by L120 was allowable loadings of 16.5 kips per pile. These demand requirements are as determined
and specified in L120's structural calculation package cited above.
As required by the referenced structural package, proof testing was to be performed to 200 percent of the
specified design load. It is L120's understanding that the installers utilized the dead weight of the existing structure
to achieve the required reaction of a test pile.
Pile capacities for helical piles have been calculated utilizing the torque correlation factors provided in ESR-3750. A
torque/capacity chart detailing this calculation has been attached to this letter. Per the attached document, an
Ideal Foundation Systems 2-7/8in diameter 10k helical pile installed to minimum pressures of 1,200psi results in an
installation torque of 4,176 ft-lbs, and an allowable capacity of 18.8 kips including a safety factor of 2.
The results are summarized below:
Maximum Demand (allowable) = 16.5 kips/pile
Available Capacity (allowable) = 18.8 kips/pile
By inspection, the pile capacities of the installed helical piles exceed the maximum loading demand as determined
by L120's analysis. Therefore, the installed piles comply with the structural design/demand.
Please contact us if you have any questions.
Sincerely,
Peter Modica, P.E.
L120 Engineering & Design (L120)
pmodica@1120engineering.com
Mans R. Thurfjell, P.E
L120 Engineering & Design (L120)
mthurfiell@1120engineering.com
7 of 27
PROJECT NO. SHEET NO.
S210728-7XR
PROJECT 9423 232ND ST SW EDMONDS, WA
LONGITUDE SUBJECT
ONE TWENTYO
ENGINEERING & DESIGN
BY PAM
Foundation Stabilization/Jacking
DATE 08/09/21
Ideal Foundation Systems 2-7/8"0
*
Helical Pile (0.203-inch wall thickness) -Soil Capacity
per ESR-3750
DIGGA lOK Drive
Head Pressure
(Psi)
Torque,
T
(ft*Ibs)
Torque Correlation Factor,
Kt [Compression]
(ft i)
Ultimate Axial Compressive Capacity,
P„ = K,*T
(kips)
Allowable Axial Compressive Capacity,
Pa = 0.5*P„
(kips)
500
1,740
9
15.7
7.8
600
2,088
9
18.8
9.4
700
2,436
9
21.9
11.0
800
2,784
9
25.1
12.5
900
3,132
9
28.2
14.1
1000
3,480
9
31.3
15.7
1100
3,828
9
34.5
17.2
1200
4,176
9
37.6
18.8
1300
4,524
9
40.7
20.4
1400
4,872
9
43.8
21.9
1500
5,220
9
47.0
23.5
1600
5,568
9
50.1
25.1
1700
5,916
9
53.2
26.6
1800
6,264
9
56.4
28.2
1900
6,612
9
59.5
29.8
L120 ENGINEERING &DESIGN
MM-10K MOUNTS
AVAILABLE TO SUIT
STAND ON MINI
MACHINES AND MINI
EXCAVATORS UP TO 3.5T
Lightweight hand-held screw anchor drive for the installation of screw
piles in confined or low access sites such as crawl spaces. This unit can be
powered by portable hydraulic power packs.
FEATURES
• Compact high torque Digga manufactured gearbox
• Lightweight and compact for ease of movement in confined spaces
• Fitted with a high efficiency Eaton/Digga geroler hydraulic motor
• Motor mounted pressure relief valve fitted standard (HH-6K)
• Over 34 years design and manufacturing experience
• 1 yr gearbox and 1 yr motor warranty
SPECIFICATIONS
MODEL
HH-6K
MM-10K
Theoretical Torque (ft-Ibs)
6,528 @ 2,100psi
10,478 @ 3,000psi
Expected Torque (ft-Ibs)
p q
4,765 @ 2,100psi
8,040 @ 3,000psi
(73%efficiency)
(77%efficiency)
Max Pressure
2,100psi @ 11 gpm
3,000psi @ 18.5gpm
Max Flow
15gpm @ 2300psi
18.5gpm @ 3000psi
Max Horse Power
20
33
Pressure Relief Valve
Included
NA
Standard Output Shaft
2" Hex
2.5" Hex -Short
Weight (Ibs)
90
138
Overall Length (in)
20"
24.1"
Diameter (in)
9.5"
11.4"
HH-6K Hand-held unit is not suitable for machine
mounting. Warranty void if used on machines.
OUTPUT SPEED &TORQUE
HH-6K
OUTPUT SPEED
GPM RPM
7 7
8 8
9 9
10 10
12 12
13 13
14 14
15 15
OUTPUTTORQUE
PSI FT-LBS
500 1,554
750 2,331
1,000 3,108
1,250 3,886
1,500 4,663
1,750 5,440
2,000 6,217
2,100 6,528
MM-10K
OUTPUT SPEED
GPM RPM
7 6
8 7
9 8
10 9
11 10
12 11
13 11
14 12
15 13
16 14
17 15
18 16
OUTPUTTORQUE
PSI FT-LBS
500 1,746
1,000 3,493
1,500 5,239
2,000 6,985
2,500 8,732
3,000 10,478
Output speed and torque specifications are THEORETICAL. Speed and torque output are dependent on the overall system efficiencies associated with the prime movers hydraulic system.
This document should be used for information and comparative purposes only. When determining criteria, & application specific information is required, please contact DIGGA.
Digga - Speed & Torque Chart
Model Code: MM - IOK
GF: 262
rpm vs Ipm
20
a 15 00
6 10
v
°J 5
a
N
0
0 20 40 60 80
Flow rate (Ipm)
Max. Flow (Ipmi)l 70
Max. Speed (rpm) 16
Output Torque
Differential
Pressure
Display
Nm
Bar
2,360
34
2,832
41
3,303
48
3,775
55
4,247
62
4,719
69
5,191
76
5,663
83
6,135
90
6,607
7,079
97
103
7,551
110
8,023
117
8,495
124
8,967
131
9,438
138
9,910
145
10,382
152
10,854
159
11,326
166
11,798
172
12,270
179
12,742
186
13,214
193
13,686
200
14,158
207
rpm vs gpm
20
u 15
10 -
v
°1 5 -
a
Vf
0 -
0 5 10 15
Flow rate (gpm)
20
Max. Flow (gpm)
18
Max. Speed (rpm)
16
Differential
Pressure
Display
Output Torque
PSI
Ibf-ft
500
1,740
600
2,088
700
2,437
800
2,785
900
3,133
1,000
3,481
1,100
3,829
1,200
4,177
1,300
4,525
1,400
4,873
5,221
1,500
1,600
5,569
1,700
5,917
1,800
6,265
1,900
6,613
2,000
6,961
2,100
7,310
2,200
7,658
2,300
8,006
2,400
8,354
2,500
8,702
2,600
9,050
2,700
9,398
2,800
9,746
2,900
10,094
3,000
10,442
* IMPORTANT: This chart is based on theoretical values and is provided as a guide only. Digga accepts no
responsibility complying with any installation requiring certain torques being reached. You will need to consult an
engineer.