REVIEWED FIR REV1 FIR2022-0104+Manufacturer_Equipment_Sheets+10.18.2022_2.37.31_PM+3171680REVISION 16Z. EF-01F40 ►a F I R2022-0104 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVIEWED CITY OF EDMONDS T CYLIN Imo— C —� NOMINAL CYLINDER DIAMETER B CENTER OF DISCHARGE PORT Component Description Figure 2-1. Dimensions of Cylinder and Valve Assembly, P/N B-12XXXX Refer to Figure 5-26 for Cylinder Valve details. Table 2-1. Cylinder and Valve Assembly Specifications Cylinder and Valve Dimensions Assembly Part Model Maximum A B C Number Flow Number B 120001 RG-1.25G 4 15-1/4 in. 13-3/4 in. 8 in. (387 nun) (349 nun) (203 nun) B120002 RG-2.5G 8 21 in. 19-5/8 in. 9 in. (534 nun) (498 nun) (230 nun) B120003 RG-4GS 12 19 in. 17-1/2 in. 12-1/4 in. (483 nun) (444 nun) (311 mm) B 120006 RG-4GM 12 24-3/8 in. 23 in. 10 in. (619 nun) (584 nun) (254 nun) B120005 RG-6G 18 35-1/8 in. 33-3/4 in. 10 in. (892 nun) (857 nun) (254 nun) P/N 9127100 2-3 January 2007 Component Description 2-1.1.1 CYLINDER BRACKETS B 'LINDER STRAP B I*-- C —0. 1 FRONT VIEW SIDE VIEW Figure 2-2. Mounting Brackets Table 2-2. Mounting Bracket Dimensions CYLINDER STRAP Edi6PidRld J Dimensions Part No. Model A B C 9197430 RG-1.25G 3 in. 9-3/8 in. 1-3/8 in. (76 mm) (238 mm) (35 mm) 9197263 RG-2.5G 4-1/2 in. 12 in. 2-1/2 in. (114 mm) (305 mm) (64 mm) 9197414 RG-4GM 4-1/2 in. 20-1/2 in. 2-1/2 in. (114 mm) (521 mm) (64 mm) 9197415 RG-4GS 4-1/2 in. 11-1/2 in. 2 in. (114 mm) (290 mm) (51 mm) January 2007 2-4 P/N 9127100 Component Description 2-1.1.2 DISCHARGE ADAPTER KIT, P/N 844908 The Discharge Adapter provides a means to connect agent distribution pipe to all Range Guard Wet Chemical Cylinder and Valve Assemblies. The Discharge Adapter Kit consists of a 3/4-inch NPT adapter and a steel flange plate (Figure 2-5). Note: The nuts and bolts used to secure the Anti -Recoil Plate to the discharge valve should be retained and used for mounting the Discharge Adapter to the valve outlet. The Discharge Adapter can also be used as a recharge adapter to pressurize the cylinder with nitrogen after filling with wet chemical. Note: This part must be ordered separately. It is not included with the Cylinder and Valve Assembly. 3/4 in. NPT �NGE PLATE /_1l7_1 i 9 =1 N Figure 2-5. Discharge Adapter Kit, P/N 844908 January 2007 2-6 P/N 9127100 Component Description 2-1.1.3 DISCHARGE NOZZLES There are essentially seven types of nozzles in the Range Guard wet chemical system. They are: • ADP • F • DM • R • GRW • LPF • LPR Each nozzle has: • Stainless steel internal strainer and nickel -chrome plated brass body • Special foil seal over the discharge orifice to prevent grease from depositing in the orifice and plugging the nozzle • Grooved rings on the body define the nozzle type (Refer to Table 2-5) P/N 9127100 2-7 January 2007 2-1.1.3.1 ADP Nozzle, P/N B120011 ADP nozzles are used for the following hazards: • Ducts • Plenums • Flat cooking surfaces (griddle) • Split Vat Deep Fat Fryers (low proximity) • Upright Broilers (Salamander) • Closed -top Chain Broilers • Open -top Chain Broilers • Natural/Mesquite Charcoal Charbroiler • Krispy Kreme Model 270 d/h Donut Fryer INTERNAL THREAD 3/8 in. NPT 13/16 in. (21 mm) 1 GROOVE —/ Component Description 9/16 in. (14 mm) Figure 2-6. ADP Nozzle, P/N B 120011 2-1.1.3.2 F Nozzle, P/N B120012 F nozzles are used for the following hazards: • Fryers • Tilt Skillets/Braising Pans • Pumice Rock (Lava, Ceramic) • Charbroilers INTERNAL THREAD 3/8 in. NPT h (48 hi 13/16 in. (21 mm) 9/16 in. (14 mm) Figure 2-7. F Nozzle, P/N B 120012 P/N 9127100 2-9 January 2007 Component Description 2-1.1.3.3 GRW Nozzle, P/N B120013 GRW nozzles are used for the following hazards: • Woks • Electric Charbroiler (Open Grid) • Radiant Charbroiler INTERNAL THREAD 3/8 in. NPT 13/16 in. (21 mm) 3 GROOVES 9/16 in. (14 mm) Figure 2-8. GRW Nozzle, P/N B 120013 2-1.1.3.4 R Nozzle, P/N B120014 R nozzles are used for the following hazard: • Ranges INTERNAL THREAD 3/8 in. NPT 13Iola in. 21 mm 4 GROOVES -/ Figure 2-9. R Nozzle, P/N B 120014 9/16 in. (14 mm) January 2007 2-10 P/N 9127100 2-2 2-2.1 Component Description CONTROLS UNIVERSAL CONTROL HEAD (UCH) Control System, P/N B120099 The UCH Control System, P/N B 120099, is used for actuating the Range Guard Cylinder and Valve Assembly. The UCH Control System can be attached to the System Valve Actuator, P/N B 120042 for direct cylinder mounting, or to a wall for remote mounting. Knockouts are provided to accommodate either type of mounting. The controller can be operated with: • Automatic mechanical detection (fusible -links and thermo-bulb links), • Automatic electrical operation, and • Remote and local manual operation. 8-3/16 in. (208 mm) Figure 2-14. UCH Control System, P/N B 120099 9-7/16 in. (240 mm) P/N 9127100 2-13 January 2007 Component Description 2-2.1.1 2-2.1.2 SYSTEM NITROGEN CARTRIDGE, P/N B 120043 The UCH Control System uses a nitrogen cartridge for actuating the wet chemical cylinders and is charged with dry nitrogen (see Figure 2-15). The cartridge is mounted inside the UCH Control System to protect it from tampering and provides the date of manufacturing and space (gray band) for recording the installation date. 5-1/8 in. (130 mm) 1-9/16 in. + (40 mm) GRAY BAND Figure 2-15. System Nitrogen Cartridge, P/N B 120043 TEST CARTRIDGE, P/N B 120044 The Test Cartridge is used for testing of the Badger Wet Chemical System. The cartridge has a red band and labeled "TEST CARTRIDGE" as shown in Figure 2-16. Note: The System Nitrogen Cartridge P/N B 120043 is required for actuation and full discharge or "puff' tests. A The Test Cartridge (P/N B 120044) must be removed and the System Nitrogen Cartridge (P/N B 120043) must be installed at the completion of any work done on the system. CAUTION Failure to do so will result in malfunction of the system. 4 in. (102 mm) ? TEST L 1 in. (25 mm) CARTRIDGE i Figure 2-16. Test Cartridge, P/N B 120044 January 2007 2-14 P/N 9127100 2-2.1.3 1-3/4 in. (44 mm) 1 SVA PIE SET POSITION Component Description SYSTEM VALVE ACTUATOR (SVA), P/N B 120042 A System Valve Actuator (SVA) is mounted to every wet chemical cylinder valve assembly (see Figure 2-17). The SVA has ports for low profile tubing runs, and is also equipped with a spring loaded plunger that locks the piston in the discharged position, ensuring complete discharge of the cylinder(s) contents. 5/16-18 UNC THROUGH HOLE (TYP) (NOT SHOWN) 1/8 in. NPT PLUG (IF APPLICABLE) 1/8 in. NPT PORT PISTON IN A( POSITION (TI CYLINDER VALVE) Figure 2-17. System Valve Actuator (SVA), P/N B 120042 RING LOADED UNGER P/N 9127100 2-15 January 2007 Component Description 2-2.1.4 HIGH-PRESSURE NITROGEN TUBING, P/N B 120045 The braided High -Pressure Nitrogen Tubing, is required on all installations in which the AUCH Control System is mounted to a wet chemical cylinder. Use of another hose in such WARNING an installation could result in death or serious personal injury and/or malfunction of the system. The High -Pressure Nitrogen Tubing is used to connect the UCH Control System to the SVA (see Figure 2-18). A 1/8-inch NPT (male) x 3/8-24 JIC Adapter is included with the High Pressure Nitrogen Tubing. 1/8 in. NPT THREAD 1/2 in. HEX, SEAT 1/4 in. 37 DEGREE FFLARE, SWIVEL A 10 (END TO SEAT) 1/8 in. NPT (MALE) x 3/8-24 JIC ADAPTER Figure 2-18. External Tubing for UCH Control System, P/N B 120045 Table 2-6. External Tubing for UCH Control System Part Number Length "A" B 120045-001 7-1/2 in. (191 mm) B120045-002 24 in. (610 mm) B 120045-003 60 in. (1524 mm) January 2007 2-16 P/N 9127100 Component Description 2-2.1.6 MICROSWITCH KIT, P/N B 120039, B 120039-501 (FOR UCH) The Microswitch Kit is a single pole, double -throw switch (see Figure 2-20 and Table 2-7). Included in the kit is the microswitch, pigtail assembly and four mounting screws (two short and two long). Note: Microswitch Kit P/N B 120039-501 includes pigtail assembly with white stripes. The wire leads are 24-inches (610 mm) in length. Four Microswitch Kits can be mounted in the UCH Control System. There are two mounting locations to accommodate the four Microswitch kits (two stacked at each mounting location), with EMT ports for each mounting location. This allows for the use of two electrical junction boxes for separation of signal lines and AC lines. These are used when it is necessary to open or close electrical circuits. The following are examples, but not limited to: • Electric appliance shutdown • Make up air shutdown • Electric gas valve shutdown • Shuntbreaker/relay Electrical appliances usually have a higher amp rating than the switches. In this case, such appliances shall not be wired directly to the microswitch. A magnetic contactor or relay must be used. To wire the microswitch for UCH, refer to Figure 4-30. ELECTRICAL CONNECTOR UUM NO MICROSWITCH Figure 2-20. Microswitch Kit, P/N B 120039 Table 2-7. Microswitch Electrical Ratings 125/250 Vac 20.5 Amps 250 Vac 1-1/2 HP 125 Vac 1/2 HP January 2007 2-18 P/N 9127100 Component Description 2-2.3 Automatic Detectors and Accessories 2-2.3.1 DETECTOR HOUSING KIT, P/N 804548 (UCH ONLY) The Detector Housing Kit, shown in Figure 2-27, consists of the following: Table 2-11. Detector Housing Kit, P/N 804548 Item (,quantity 7-9/16 in. (192 mm) Detector Housing 1 1/2-inch EMT Connectors 2 Crimp Sleeves 4 "S" Hook 1 These items are used to attach the detectors to the 1/16-inch cable leading to the UCH Control System. The Detector Housing can be configured as an End -of -Line or In -Line bracket. EXAMPLE OF IN -LINE DETECTOR HOUSING KIT 1/2 in. EMT "S" HOOKS PIPE (NOT LOCKNUT SUPPLIED) (NOT SUPPLIED) _ "S" HOOKS _ — �! 1-1/2 in. — (38 mm) THERMO-BULB OR MIN. FUSIBLE -LINK 1/16 in. CABLE (NOT SUPPLIED) TO UCH CONTROL SYSTEM CRIMP (NOT SUPPLIED) SLEEVE EXAMPLE OF END -OF -LINE DETECTOR HOUSING KIT THERMO-BULB OR FUSIBLE -LINK (NOT SUPPLIED) 1/2 in. EMT CONNECTOR AND LOCKNUT (NOT SUPPLIED) • 1/16 in. CABLE TO UCH CONTROL SYSTEM (NOT SUPPLIED) Figure 2-27. Example of End -of -line and In -line Detector Housing Kit, P/N 804548 January 2007 2-24 P/N 9127100 Component Description 2-2.3.4 FUSIBLE -LINKS, P/Ns B282661, B282662, B282664 and B282666 Fusible -Links are available in various temperature ratings with a minimum/maximum load rating of 10 lb./40 lb. (5 kg/18 kg) (see Table 2-14). Figure 2-30. Fusible -Link, P/N B28266X Table 2-14. Fusible -Link Temperature Ratings Fusible -Link Rating Maximum Exposure Temperature Color Part Number 1650F (74°C) 100OF (38°C) Yellow B282661 212OF (100°C) 150°F (65°C) White B282662 360OF (182°C) 300OF (149°C) Unpainted B282664 500OF (260°C) 440OF (226°C) Orange B282666 The rating temperature, which is stamped on the Fusible -Link, is the temperature at which the link will separate when new. However, continual exposure to cycling ambient temperatures may cause a degradation of the link over time. P/N 9127100 2-27 January 2007 Component Description 2-2.3.7 CORNER PULLEY, P/N B844648 The Corner Pulley is used to change the direction of the control cable runs. The cable's protective conduit (1/2-inch EMT) is attached to the Corner Pulleys with the coupling nuts provided. The Corner Pulley is equipped with a ball -bearing pulley for minimum resistance to the cable travel. 3 in. (76.2 mm) 3 in. (76.2 mm) Figure 2-32. Corner Pulley, P/N B844648 P/N 9127100 2-29 January 2007 Component Description 2-2.4 Remote Manual Releases 2-2.4.1 REMOTE MANUAL RELEASE, P/N B875572 (UCH ONLY) The Remote Manual Release, shown in Figure 2-34, is provided as a means of manually actuating the system from a remote location. The Remote Manual Release is attached to the UCH Control System with 1/1 6-inch control cable. To actuate the system at the Remote Manual Release, pull out the safety pin and pull hard on the handle. Each Remote Manual Release is supplied with a separate nameplate. This nameplate must be attached to the mounting surface 1-inch above or below the Remote Manual Release. Figure 2-34. Remote Manual Release, P/N B875572 P/N 9127100 2-31 January 2007 Component Description 2-3.3 Mechanical Gas Valve, P/N B 12007X A Mechanical Gas Valve is required on systems used to protect gas -fueled appliance(s). Upon system actuation, the control stem closes, stopping the gas flow to the appliance(s). Note: Only Mechanical Gas Valves that are specifically UL listed and identified by part number in this manual may be used with the Range Guard system. INLET —\ ZOL STEM OUTLET Figure 2-41. Mechanical Gas Valve, P/N B 12007X Table 2-17. Mechanical Gas Valve Sizes Pipe Size Part Number 3/4 in. (19 mm) B 120071 1 in. (25.4 mm) B120072 1-1/4 in. (32 mm) B120073 1-1/2 in. (38 mm) B120074 2 in. (51 mm) B120075 2-1/2 in. (64 mm) B120076 3 in. (76 mm) B 120077 January 2007 2-38 P/N 9127100 Component Description 2-3.6 EMT and O-Ring Connector Kit, P/N B 120058 If using more than the three EMT connectors supplied with the UCH Control System, you must use EMT Connector and O-Ring Connector Kit. Figure 2-45. EMT and O-Ring Connector Kit, P/N B 120058 2-3.7 1/16-inch Control Cable, P/N 219649 The Control Cable used in the system is stainless -steel, 1/16-inch O.D., 7x7 stranded cable. The control cable runs from the various system devices, through 1/2-inch EMT conduit, to the UCH or A+ Control System. Table 2-19. 1/16-inch Control Cable Part Number Description 219649 1/16, 7x7 Cable, Stainless Steel, Reel of 500 ft. (152 m) 2-3.8 Crimp Sleeve, P/N 214951 In order to ensure that a crimp sleeve is secure, the cable must always be looped so that there are two lengths of cable inside the Crimp Sleeve before crimping. Cable must not be spliced anywhere along its length. Figure 2-46. Crimp Sleeve, P/N 214951 Table 2-20. Crimp Sleeve Part Number Description 214951 Cable Crimp Sleeve (order in package of 50 only) 9197288 Cable Crimp Sleeve (package of 50 of 214951) P/N 9127100 2-41 January 2007 cl:) Component Description 2-3.11 1/2-inch Vent Plug, P/N 9196984 A 1/2-inch Vent Plug is used in the discharge piping near a Range Guard cylinder to prevent pressure build-up in the discharge pipe system, caused by heat, from rupturing the foil seals on each nozzle. The 1/2-inch Vent Plug is to be installed in the discharge piping so that it faces the ceiling or the wall. A NEVER INSTALL IT FACING DOWN OR AT THE FLOOR. CAUTION 1/2 in. (13 mm) N PT Figure 2-49. 1/2-inch Vent Plug, P/N 9196984 2-3.12 Keeper Pin, P/N 9197108 The Keeper Pin (P/N 9197108) is used to prevent actuation while installing the system. Figure 2-50. Keeper Pin, P/N 9197108 2-3.13 System Recharge For recharge purposes, select the size of the Karbaloy agent recharge container (see Table 2-22) that fits the cylinder. Table 2-22. Wet Chemical Agent Part Number Wet Chemical 9197428 RG-1.25G Karbaloy Recharge Container 9197257 RG-2.5G Karbaloyl Recharge Container 9196991 RG-4GS/RG-4GM Karbaloy Recharge Container 9196783 RG-6G Karbaloy Recharge Container P/N 9127100 2-43 January 2007 System Design 3-4.9 Four Burner Ranges Table 3-13. R Nozzle Coverage Area — Four Burner Range Items Parameters Maximum Hazard Area 28 in. x 28 in. (711 mm x 711 mm) Nozzle Aim Midpoint of Hazard Area Nozzle Location — Anywhere within the area of a circle 20 in. (508 mm) Min. generated by a 9 in. (229 mm) radius about the midpoint 42 in. (1067 mm) Max. Note: Shape of burner not important. 20 in. (508 mm) MIN. (FROM TOP OF RANGE) 28 in. (711 mm) MAX.HAZARD AREALENGTH 18 in. (457 mm) DIA. 42 in. (1067 mm) MAX. (FROM TOP OF RANGE) A `R' NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE SHADED AREA AIM POINT. MIDPOINT OF HAZARD AREA �1► rI► KI V 4: NOW M"'M i i i 14 in. (356 mm) MAX. BURNER CENTERLINE TO CENTERLINE 28 in. (711 mm) MAX. HAZARD AREA WIDTH 14 in. (356 mm) MAX. BURNER CENTERLINE TO CENTERLINE Figure 3-10. R Nozzle Coverage for a 4-Burner Range P/N 9127100 3-15 January 2007 3-6 VENTILATION 3-6.1 Plenums Table 3-29. Plenum Protection System Design Items Parameters ADP Nozzle No Filter 1 10 ft. x 4 ft. (3 m x 1.2 m) Max. 1 - located at one end of the plenum "V" Filter 10 ft. x 4 ft. (3 m x 1.2 m) 20 ft. x 4 ft. (6 m x 1.2 m) 1 - located at one end of the plenum 2 - located at end of plenum pointing inwards Single Bank Filter 10 ft. x 4 ft. (3 m x 1.2 m) 20 ft. x 4 ft. (6 in x 1.2 m) 1 - located at one end of the plenum 2 - located at end of plenum pointing inwards 1 When no filters are present, the nozzle protecting the plenum is used to discharge the wet chemical on the under- side of the hood. In this case, the hood may not exceed a length of 10 ft. (3 m) or a width of 4ft(1.2m). Longer plenums may be similarly protected with a single ADP nozzle being used for each 10 ft. (3.0 m) of plenum length and each 4 ft. (1.2 m) of plenum width. ADP nozzles may be used in combinations (see Figure 3-28). Multiples may be installed facing in the same direction, and/or at the ends of the plenum pointing in. Each nozzle shall provide a maximum of 10 ft. (3 m) of coverage. ADP nozzles must be centrally located in the plenum with their discharge directed along the length of the plenum and located in relation to the filters as shown in Figure 3-28. Refer to Figure 3-28 for filter height. P/N 9127100 3-33 January 2007 System Design 4 ft. (1.2 m) 4 ft. (1.2 m) "V" FILTER BANK COVERAGE 10 ft. (3 m) PLENUM 4 ft. (1.2 m) DUCT 4 ft. (1.2 m) I 10 ft. (3 m) I - NOZZLE NOZZLE 0141 4 ft. (1.2 m) 411F'It�. NOZZLE 3/4 H 2 i H "V" FILTER BANK COVERAGE (END VIEW) SINGLE FILTER BANK COVERAGE 10 ft. (3 m) PLENUM NOZZLE (1.2 m)',*,, " I *' - - ♦11/3 WIt- i 314 H � k T �P i I♦W♦I SINGLE BANK FILTER COVERAGE (END VIEW) NOZZLE 4 ft. (1.2 m) 20 ft. (6 m) "V" FILTER BANK COVERAGE 20 ft. (6 m) PLENUM SINGLE FILTER BANK COVERAGE 20 ft. (6 m) PLENUM Figure 3-28. ADP Protection Nozzle, P/N B 120011 January 2007 3-34 P/N 9127100 3-6.1.1 3-6.1.1.1 System Design DUCTS The ADP nozzle, P/N B 120011, is used for protection of the exhaust ductwork. The duct cross section can be any shape, not including obstructions (i.e., round, square, or rectangular) and the duct itself can be of unlimited length. In accordance with NFPA 96, the exhaust fan should be left running at the time of system discharge. This will help to remove smoke and other airborne materials and gases from the hazard area in the event of a fire. Check with the Authority Having Jurisdiction for local requirements. A damper, if present, should be left open at system discharge. However, if the damper is closed, the system designer must insure that additional nozzles are required. Protection of Ducts 0 to 50 inches in Perimeter One ADP nozzle, P/N B 120011, is required for protection of a duct with a perimeter up to 50-inches (refer to Figure 3-29). Length of duct is unlimited. The nozzle is located at the geometric center of the cross -sectional area that it is protecting, and is located in the duct within six inches of the entrance. Note: All Range Guard systems are listed by UL and ULC for use with the exhaust fan either on or off when the system is discharged. DUCT PERIMETER UP TO AND INCLUDING 50 in. (1270 mm) 11.78 in. (300 mm) 15.91 in. MAX. DIAGONAL (404 mm) I4 «B» �I ♦ � MAX. 12.5 in. f 11.78 in. (300 mm) (318 mm) — I — MAX. DIAGONAL "All MAX. "A/1 SQUARE DUCT I RECTANGULAR DUCT 2 "A°' + 2 "B" = 65 in. (1651 mm) ROUND DUCT i ADP NOZZLE i i i 1 0 - 6 in. (0 - 152 mm) DUCT ENTRANCE VERTICAL/HORIZONTAL DUCT t OZZLE 2 to 4 in. (51 to 102 mm) NOZZLE TIP to DUCT HIP (L OF VERTICAL DUCT .� AIM POINT i i L(LOF HORIZONTAL DUCT i Figure 3-29. Duct Protection Using Single ADP Nozzle, P/N B 120011 P/N 9127100 3-35 January 2007