FIR2020-0091+Approved_Remodel_Plans+10.28.2020_8.57.55_AM (2)DESIGN ARCHITECT F E D C B A ABBREVIATIONS AC AIR CONDITIONING ACC ACCESSIBLE ACT ACOUSTICAL CEILING TILE ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR AHJ AUTHORITIES HAVING JURISDICTION AMP AMPERE AOR ARCHITECT OF RECORD APPROX APPROXIMATE BOH BACK OF HOUSE BLDG BUILDING CAB CABINET CKT CIRCUIT CL CENTER LINE CLG CEILING CLR CLEAR OR CLEARANCE COL COLUMN COMP COMPARTMENT CONST CONSTRUCTION CONT CONTINUOUS CTR CENTER CW COLD WATER CWF COLD WATER FILTERED CX COMMISSIONING CXA COMMISSIONING AGENT DEG DEGREES DIETDETAIL DIA DIAMETER DISP DISPENSER DIM DIMENSION DM STARBUCKS DESIGN MANAGER DN DOWN DPM STARBUCKS DESIGN PROGRAM MANAGER DWG(S) DRAWING(S) EA EACH r-_-_-_-_-_-_-_-_-_-_-_--, EC ELECTRICAL CONTRACTOR Separate Plumbing permit is I EL ELEVATION ELEC ELECTRICAL ;required for this I project. I EM EQ EMERGENCY EQUAL I I EQUIP EQUIPMENT EXIST OR (E) EXISTING - -- - - - - - - - - - - - - - - - - - - - - - - -I EXP EXPOSED EXT EXTERIOR FC STARBUCKS FIXTURE CONTRACTOR/INSTALLER FCO FLOOR CLEANOUT FD FLOOR DRAIN FF&E FURNITURE, FIXTURE AND EQUIPMENT F&I FURNISH AND INSTALL OBTAIN ELECTRICAL PERMIT FROM FIN F R FINISH FLOOR STATE LABOR & INDUSTRIES FOH FRONT OF HOUSE FRP FIBERGLAS REINFORCED PANEL FS FLOOR SINK FT FOOT OR FEET APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT I TO FIELD INSPECTION FOR CODE COMPLIANCE GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND HDW HARDWARE HORIZ HORIZONTAL HR HOUR HS HAND SINK HT HEIGHT HVAC HEATING, VENTILATING AND AIR CONDITIONING HW HOT WATER ID INSIDE DIAMETER LC OWNER LL LANDLORD LV LOW VOLTAGE MAX MAXIMUM MC MECHANICAL CONTRACTOR MECH MECHANICAL MEP MECHANICAL, ELECTRICAL AND PLUMBING E MFR MANUFACTURER MIN MINIMUM I 0 d sYOfm n MS MOP SINK Building Department Work STARBUCKS REMODEL Address Owner SAFEWAY STORE Approved Date 8/12/2020 Building Official Dana.ucm L Azaa Permit Number BLD2020-0728 CITY OF EDMONDS BUILDING DIVISION APPROVED PLAN NIC NOT IN CONTRACT NTS NOT TO SCALE CA OVER ALL OC ON CENTER OD OUTSIDE DIAMETER PC PLUMBING CONTRACTOR PM STARBUCKS PROGRAM MANAGER PDM STARBUCKS PROJECT DEVELOPMENT MANAGER PLAM PLASTIC LAMINATE POS POINT OF SALE R RADIUS REF REFERENCE REQ('D) REQUIRE(D) REV REVISION RND ROUND SB STARBUCKS SF SQUARE FEET SHT SHEET SIM SIMILAR SPEC SPECIFICATION SQ SQUARE SST STAINLESS STEEL SUSP SUSPENDED TEL TELEPHONE TEMP TEMPORARY TW TEMPERED WATER TYP TYPICAL UC UNDERCOUNTER LION UNLESS OTHERWISE NOTED VD VENDOR DIRECT VERT VERTICAL VIF VERIFY IN FIELD W SANITARY WASTE WH WATER HEATER WP WEATHER PROOF WCO WALL CLEANOUT REFERENCE SYMBOLS NORTH ARROW EXTERIOR ELEVATION CALL -OUT XX SHEET NOTE CALLOUT REVISION TAG 0 1' 2' 4' 8' GRAPHIC DATUM SCALE POINT INTERIOR SECTION DETAIL ELEVATION CALL -OUT CALL -OUT CALL -OUT XXXX AFF X. XX" ABOVE FINISH FINISH REVISION FLOOR FACE TO CLOUD HEIGHT TAG FINISH FACE DIMENSION PXXX-ES X XXXX D XXXX W XXXX PAINT DESIGN ID DOOR WINDOW TAG TAG TAG TAG GENERAL NOTES 1. THESE DRAWINGS AND THE PROJECT MANUAL TOGETHER CONSTITUTE THE STARBUCKS DESIGN DEVELOPMENT SET. ALL GENERAL REQUIREMENTS ARE TO BE MET AND ALL MATERIALS, FINISHES, AND SYSTEMS ARE TO BE INSTALLED PER SPECIFICATIONS UNLESS NOTED OTHERWISE. 2. NOT USED 3. GENERAL CONTRACTOR SHALL VISIT THE SITE AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO CONSTRUCTION. 4. GENERAL CONTRACTOR SHALL CONSULT WITH STARBUCKS PROJECT DEVELOPMENT MANAGER TO RESOLVE ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES PRIOR TO CONSTRUCTION. 5. ALL WORK SHALL BE PERFORMED IN A STRICT COMPLIANCE WITH LOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES. 6. GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES. 7. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKS PROJECT DEVELOPMENT MANAGER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO NOT SCALE DRAWINGS. 8. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS, OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 9. GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE PROTECTION, PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS PRIOR TO INSTALLATION OF SUCH SYSTEMS. 10. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF PERMIT PLANS ON -SITE TO DOCUMENT ALL CHANGES MADE DURING CONSTRUCTION. THE RECORD DRAWINGS SHALL BE ISSUED TO THE OWNER AND THE STARBUCKS PROJECT DEVELOPMENT MANAGER AT PROJECT CLOSEOUT AS DESCRIBED IN THE GENERAL REQUIREMENTS OF THE PROJECT MANUAL. 11. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DELIVERY OF MATERIAL FROM STARBUCKS CONTRACTED THIRD PARTY LOGISTICS DISTRIBUTIONS SERVICES AND VENDOR DIRECT SHIPMENTS. SEE PROJECT MANUAL FOR ADDITIONAL INFORMATION. 12. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT IS IDENTIFIED IN THE DRAWINGS AND SCHEDULE SHEETS UNDER THE COLUMN LABELED "RESPONSIBILITY" 13. FOR THE PURPOSE OF THE DOCUMENTS, TO "INSTALL", SHALL MEAN TO PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, ELECTRICAL CONNECTIONS, PLUMBING CONNECTIONS AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION, UNLESS OTHERWISE NOTED. 14. ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE STARBUCKS DESIGN MANAGER AND/OR PROJECT DEVELOPMENT MANAGER. CUSTOM DESIGN ID KEY SIGNAGE 'IS'. x0000 - x0999 GRAPHICS AND ARTWORK "G" x1000 - x1099 SITE "Y" x1100 - x1199 DOORS "D" x2000 - x2999 DATA DEVICE "A" x3000 - x3999 SPECIALITY EQUIPMENT "E" x4000 - x4999 CASEWORK "C" x5000 - x5999 FURNITURE "F" x6000 - x6999 LIGHTING FIXTURE "L" x7000 - x7999 PLUMBING / MECHANICAL "P" / "M" x8000 - x8999 FINISHES - PAINT x9000 - x9199 FINISHES - FLOOR TREATMENT "T" x9200 - x9399 FINISHES - WALL TREATMENT "Q" / "R" x9400 - x9799 FINISHES - CEILING TREATMENT "U" x9800 - x9999 STARBUCKS RESPONSIBILITY LEGEND -GROCERY KIOSK 3PV / 3PV FURNISHED BY 3RD PARTY VENDOR / INSTALLED BY 3RD PARTY VENDOR 3PV / GC FURNISHED BY 3RD PARTY VENDOR / INSTALLED BY OWNER'S CONTRACTOR GC/GC FURNISHED BY OWNER'S CONTRACTOR / INSTALLED BY OWNER'S CONTRACTOR LC / GC FURNISHED BY OWNER / INSTALLED BY OWNER'S CONTRACTOR SB / 3PV FURNISHED BY STARBUCKS / INSTALLED BY 3RD PARTY VENDOR SB/GC FURNISHED BY STARBUCKS / INSTALLED BY OWNER'S CONTRACTOR STARBUCKS KIOSK REMODEL EDMONDS, WASHINGTON _EXISTING VICINITY MAP • � SAFEWAY - . - :, �' 4 ' 236TH ;! ST SW i �. .. + l � f 4 r G J I ,7 • . : \t , Y it _.�'• 38TH ST SW,NORTH BUILDING CODE INFORMATION JURISDICTION: CITY OF EDMONDS APPLICABLE CODES: BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE LOCAL BUILDING CODE: 2015 WASHINGTON STATE BUILDING CODE EXISTING BUILDING CODE: 2015 INTERNATIONAL EXISTING BUILDING CODE ELECTRICAL CODE: 2017 NATIONAL ELECTRICAL CODE MECHANICAL CODE: 2015 INTERNATIONAL MECHANICAL CODE PLUMBING CODE: 2015 UNIFORM PLUMBING CODE FIRE CODE: 2015 INTERNATIONAL FIRE CODE ENERGY CODE: 2015 WASHINGTON STATE ENERGY CODES ACCESSIBILITY CODE: 2009 ICC A117.1 BARRIER FREE STANDARD HEALTH CODE: WASHINGTON STATE RETAIL FOOD CODE OCCUPANCY GROUP: �B I CONSTRUCTION TYPE: III -A SPRINKLERED SPRINKLERED: YES (EXISTING) FIRE ALARM SYSTEM: YES (EXISTING) ZONING INFORMATION PARCELS: 00451900100401 LEGAL DESCRIPTION: FRUITLAND ACRES TO LAKE BALLINGER BLK 001 D-01 TH PTN LOTS 4 THRU 18 BLK 1 LY WLY OF W MGN PACIFIC HWY (99 N)& N OF NLY MGN 238TH ST & S OF SLY MGN 236TH ST SW & E OF FDL BEG AT INT OF W LN OF E 120FT OF LOTS 9,10 & 11 SD BLK 1SD PLAT WH S MGN 236TH ST SW TH S ALGSD W LN TO S LN SD LOT 11 TH W ALG SD S LN DIST 70FT TO INT W LN OF E 19OFT LOTS12,13 & 14 SD BLK 1 SD PLAT TH S ALG SD LAST LAST NAMED W LN TO N MGN 238TH ST SW & TERM SD DESC LN & LESS PTN TOSNO CO DAF TH PTN LY ELY OF FDL BAAP ON WLY MGN PACIFIC HWY (99 N) WH IS 75.9FT SWLY ALG SD WLY MGN FIR OTS INT WH SLY MGN 236TH ST SW TH ON A TANG CRV TO LWH A RAD OF 47.5FT TO INT SD SLY MGN OF 236TH ST SW & TERM SD LN DESC PER WD AF 9104100295 & LESS PTN TO SNO CO DAF TH PTN LY ELY OF FDL BAAP ON WLY MGN PACIFIC HWY (SR-99N) WH IS 15.64FT NELYALG SD WLY MGN FIR ITS INT WH NLY MGN 238TH ST SW TH ON A TANG CRV TO L WH A RAD OF 25FT TO INT SD NLY MGN OF 238TH ST SW & TERM SD DESC LN ZONING: GENERAL COMMERCIAL EXISTING BUILDING AREA: 48,799 SF AREA OF WORK: 784 SF SEWER DISTRICT: OLYMPIC VIEW SEWER SERVICE WATER DISTRICT: OLYMPIC VIEW WATER SERVICE SCOPE OF WORK PROJECT DIRECTORY VVVIVCR. SAFEWAY INC. 1371 ORCHARD BLVD. #200 WALNUT CREEK, CA 94596 PHONE: 425-201-6411 CONTACT: JOE JANUS EMAIL: JOE.JANUS@SAFEWAY.COM GENERAL CONTRACTOR: TRICON 385 OLD CORVALIS ROAD HAMILTON, MT 59840 PHONE: 406-381-3785 CONTACT: BILL RANDALL EMAIL: BILLR@TC-CONST.COM ARCHITECT: GRAPHITE DESIGN GROUP 1809 7TH AVENUE, SUITE 700 SEATTLE, WA 98101 PHONE: 206-224-3335 CONTACT: GARY BARBER EMAIL: GARY.BARBER@GRAPHITEDESIGNGROUP.COM MECHANICAL/PLUMBING/ELECTRICAL: HARGIS ENGINEERING 1201 THIRD AVE., SUITE 600 SEATTLE, WA 98101 PHONE: (206) 448-3376 CONTACT: ROBERT SMITH, PE EMAIL: ROBERT.SMITH@HARGIS.BIZ DRAWING INDEX GENERAL A-001 GENERAL INFORMATION A-002 SITE PLAN A-003 KEY PLAN D-101 DEMOLITION FLOOR PLAN D-102 RELOCATION PLAN A-101 FF&E PLAN A-102 CASEWORK PLAN A-201 INTERIOR FINISH ELEVATIONS REMOVE EXISTING STAND-ALONE INTERIOR SALES KIOSK; INSTALL NEW KIOSK IN SAME LOCATION; NEW EQUIPMENT AND CASEWORK; REINSTALLATION OF SOME EXISTING EQUIPMENT AND CASEWORK (AS E-0001 ELECTRICAL NOTES & SPECIFICATIONS NOTED) IN CONFIGURATION SHOWN; MINIMAL ALTERATIONS TO PLUMBING AND ELECTRICAL E 1101 ELECTRICAL DESIGN PLAN CONNECTIONS AS REQUIRED. PI I IMRINI(; SCHEDULE PREFIX A - DATA DEVICE SCHEDULE B - WALL BASE SCHEDULE C - CASEWORK SCHEDULE D - DOOR SCHEDULE E - SPECIALTY EQUIPMENT SCHEDULE F - FURNITURE SCHEDULE G - GRAPHICS AND ARTWORK SCHEDULE L - LIGHTING FIXTURE SCHEDULE M - MECHANICAL EQUIPMENT SCHEDULE P - PLUMBING FIXTURE SCHEDULE Q - WALL TREATMENT (AREA) SCHEDULE R - WALL TREATMENT (LENGTH) SCHEDULE S - SIGNAGE SCHEDULE T - FLOOR TREATMENT SCHEDULE U - CEILING TREATMENT SCHEDULE W - WINDOW SCHEDULE Y - SITE SCHEDULE P-0001 PLUMBING NOTES & SPECIFICATIONS P-1101 PLUMBING DESIGN PLAN RECEIVE Jul 28 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GRAPHITE Graphite Design Group, LLC 1809 7th Avenue, Suite #700 Seattle, WA 98101 206.224.3335 www.graphitedesigngroup.com OWNER SAFEWAY Safeway, Inc. 1371 Orchard Blvd. #200 Walnut Creek, CA 94596 425.201.6411 CONSULTANT SEAL 9336 X REG MARTIN LEE HILL ITE OP WASHINGTONV Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED / REVISED DATE PERMIT SET 07/15/2020 GENERAL INFORMATION A-001 DESIGN ARCHITECT F E D C B A SITE PLAN Scale: 1" = 30' M T H T 236TH ST- S EXISTING TRASH COMPACTOR (TO REMAIN AS IS) 0 ° ° ►ND COMPOST IS SAFEWAY AND AT THEIR AUBURN II SHEET SYMBOLS — — — — > — — — — ACCESSIBLE ROUTE N 0 15' 30' 60' MEMEM Scale:1 -30' RECEIVE Jul 28 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GRAPHITE Graphite Design Group, LLC 1809 7th Avenue, Suite #700 Seattle, WA 98101 206.224.3335 www.graphitedesigngroup.com O';;'NER MFEWAY Safeway, Inc. 1371 Orchard Blvd. #200 Walnut Creek, CA 94596 CONSULTANT SEAL $ REGI SVAI Q APOZ Ill LEE HILL STATE OF WASHINGaTON Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED I REVISED DATE PERMIT SET 07/15/2020 SITE PLAN A-002 F E D C B A KEY PLAN 1 scale: 1/16" = 1'-0" PROJECT LOCATION 0 EXISTING MOP SINK w EXIT ❑o■ All( N 0 8' 16' 32' Scale: 1/16" = 1'-0" RECEIVE Jul 28 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DESIGN ARCHITECT GRAPHITE Graphite Design Group, LLC 1809 7th Avenue, Suite #700 Seattle, WA 98101 206.224.3335 www,graphitedesigngroup.com OWNER MFEWAY Safeway, Inc. 1371 Orchard Blvd. #200 Walnut Creek, CA 94596 425.201.6411 CONSULTANT SEAL 8= REG[ D APO MARTIN LEE HILL STATE OF WASHINGTON Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED / REVISED DATE PERMIT SET 07/15/2020 KEY PLAN A-003 DESIGN ARCHITECT F E D C B A ELEVATION - FRONT DEMO (�)KIOSK Scale: 3/8" = 1'-0" �v r 26 23 vv II I 12 �L------------- /I / I I II I 24 _I 22 I II 25 I I II I I II — 5), \ I \ \ / / / / I I I III III 14 T I O4 KIOSK ELEVATION -- CONDIMENT CART DEMO Scale: 3/8" = 1'-0" 3OKIOSK ELEVATION - GATE DEMO Scale: 3/8" = 1'-0" 22 J_7=�71 III 26 I II -- L I� 1 11 I \\ III II I 25 I I I! (cIIIU- - - C C rill III O5 KIOSK ELEVATION - CBS DEMO Scale: 3/8" = V-0" `V 17 T i� ---------------------------------------------- 22 16 13 \ 14 r�<�C) 1 1 \ ❑1 --d 15 I II a �� II II II 10rr- �I I JJr� II 111 11 p111 \\ // r-� I 17 18 III II p�� III �I III - V_ I I II 6 1 1-II I II �- LEI I- II II I I III L- I 1�11 3 5 8 19 �I 1 1� 11 II 11 Intl __I 1 20 23 24 25 26 7�� �1 1�- -� �-ti" ==N� jell I �-sll 11JI �— �- 11 27 2 1L 11 ������I 1 21 / 11 1 A \ — IIII % I - I J� LJI I �1 II I� II I I-c II I I --n III 18 i l �\ II I I II IIL- III K� v I III I I jr- \\ 1FF=-�1 � ♦ � � II II Ir i DLF Q 1 ODEMOLITION FLOOR PLAN Scale: 1/4" = 1'-0" 7' - 4 1 /2" EXISTING DATUM II LLL CV i 0 Z F_ X W KEYED NOTES 1. REMOVE EXISTING FLOOR FINISHES AS INDICATED. REPAIR OR REPLACE SUB -FLOOR AS REQUIRED TO PROVIDE AN EVEN WALKING SURFACE AND FINISHED FLOOR CONDITION. 2. REMOVE EXISTING FIXTURES, FURNITURE, AND EQUIPMENT AS INDICATED. REFERENCE SCHEDULES ON THIS SHEET FOR ITEMS TO BE PRESERVED. 3. EXISTING KIOSK TO REMAIN. 3PV TO DISASSEMBLE AND REINSTALL IN NEW LOCATION. GC TO CONFIRM AND COORDINATE DATUM POINT DIMENSIONS WITH PROPOSED PLAN. 3PV AND GC TO COORDINATE INSTALLATION AND RESPONSIBILITIES 4. KIOSK EXISTING DATUM 5. ALL EQUIPMENT TO REMAIN FOR REUSE, UON. SERVICE AND/OR REPAIR AS REQUIRED. 6. MERCHANDISE FIXTURES TO REMAIN FOR REUSE • BASKETS (4) 7. OWNER PROJECT MANAGER TO DETERMINE IF EXISTING POS EQUIPMENT WILL BE PRESERVED FOR REUSE 8. 3PV TO REMOVE EXISTING DOPPIO 3-PANEL MENU BOARD. 9. EXISTING MASTRENA TO BE STORED BY OWNER FOR FUTURE USE. 10. 3PV TO MODIFY EXISTING ESPRESSO AND CBE COUNTER TO ACCOMMODATE NEW LAYOUT. 11. 3PV TO DEMO DIE WALL AND GATE IN PREPARATION FOR ICE TOWER EXPANSION; 3PV TO ASSESS IF EXISTING SWING GATE CAN BE RE -USED IN EXPANSION ASSEMBLY. 12. 3PV TO DEMO TOP 1/4 OF STORAGE CABINET; ALTER STORAGE BELOW AS NEEDED TO ACCOMMODATE NEW COUNTER. 13. 3PV TO MODIFY EXISTING DIEWALL(S) AS NEEDED IN PREPARATION OF NEW LAYOUT. 14. 3PV TO REDUCE HEIGHT OF SIDEWALL IN PREPARATION FOR LARGER HANDOFF PLANE. 15. 3PV TO REMOVE EXISTING HANDOFF COUNTER. 16. 3PV TO REMOVE EXISTING DIPPER WELL AND PREPARE FOR REINSTALLATION PER PLAN 17. DEMOLISH EXISTING VERTICAL CUP HOLDERS 18. DEMOLISH EXISTING ICE MACHINE AND PASTRY CASE 19. DEMOLISH EXISTING COMPOSITE COUNTERTOPS AND PREPARE FOR NEW COMPOSITE COUNTERTOPS PER CASEWORK PLAN 20. REMOVE EXISTING PLUMBING FIXTURES AS INDICATED. CAP LINES AS NECESSARY FOR THOSE NOT BEING REUSED. 21. 3PV TO REMOVE EXISTING POS COUNTERTOPS AND CASH CORRALS. TOPS OF (2) POS CABINETS TO ALIGN WITH THE HEIGHT OF THE FINISHED COUNTERTOP AT 2'-10" AFF. 22. EXISTING LOGO SIGNAGE ON FRONT OF KIOSK TO REMAIN. 23. DEMOLISH EXISTING LOGO SIGNAGE ON REAR OF KIOSK. 24. DEMOLISH EXISTING WORDMARK SIGNAGE. 25. 3PV TO REMOVE EXISTING SNEEZE GUARD 26. REMOVE EXISTING CASEWORK, HANGING DEVICES, AND FASTENERS AS INDICATED. REMOVE ASSOCIATED ELECTRICAL AND DATA LINES NOT BEING RE -USED. 27. DEMOLISH EXISTING PENDANT LIGHT FIXTURES (3) AND CUSTOMER COUNTER. GENERAL NOTES A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL CONTRACTOR TO IMMEDIATELY NOTIFY STARBUCKS PROJECT DEVELOPMENT MANAGER. B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULL SCOPE OF WORK. C. REMOVE WALL COVERINGS ON EXISTING WALLS TO REMAIN THAT FACE AREAS OF DEMOLITION. REMOVAL SHALL INCLUDE ANY RESIDUAL MATERIAL AFTER DEMOLITION, I.E. PIECES OF WALL COVERING OR BACKING. REMOVAL OF ALL COVERINGS IS TO BE DONE W/O DAMAGING THE EXISTING WALL SURFACE TO REMAIN. ALSO REMOVE WALL DEVICES AND ITEMS MOUNTED TO WALLS. D. REMOVE ALL FLOOR MATERIALS INCLUSIVE OF SETTING BEDS, SUBFLOOR MATERIAL ETC. REMOVE MASTIC TO PROVIDE A CLEAN FLOOR THAT IS ACCEPTABLE TO THE SUBCONTRACTOR INSTALLING NEW FINISH MATERIAL. E. DEMOLITION PLANS REPRESENT APPROXIMATE LOCATION OF EXISTING WALLS TO BE DEMOLISHED. FIELD VERIFY TYPE OF CONSTRUCTION AND HEIGHT OF WALLS. PLANS DO NOT NECESSARILY INDICATE ALL DEMO WALLS, COUNTERS, HANDRAILS, WALL PROTECTION, CLOSETS, SINKS, ETC. PRIOR TO DEMOLITION, FIELD VERIFY THAT WALLS TO BE REMOVED DO NOT PROVIDE SUPPORT FOR EXISTING BUILDING ELEMENTS AND EXISTING CONSTRUCTION TO REMAIN. F. DEMOLISH AND REMOVE DOORS, VINYL BASE, CONDUIT, WIRING, DUPLEXES, DATA OUTLETS, CABLES, SHELVING, METAL STUD AND GYPSUM BOARD WALLS, CLOSETS, CABINETS, FILES, COUNTERS, WOOD MOLDING, SHELVES AND ENCLOSURES WHERE APPLICABLE. G. VERIFY ACCESS TO THE DEMOLITION AREA, INGRESS AND EGRESS ROUTES FOR MATERIAL AND EQUIPMENT WITH OWNER. H. PROTECT EXISTING FLOORS, WALLS AND CORNERS TO REMAIN ALONG WORK ACCESS ROUTES. I. CONTAIN DUST AND DEBRIS WITHIN THE DEMOLITION AREA. J. GENERAL CONTRACTOR SHALL PERFORM WORK IN A MANNER THAT DOES NOT DAMAGE THE EXISTING STRUCTURE. DEMOLITION SHALL NOT COMPROMISE THE STRUCTURAL INTEGRITY OF ANY WALLS, FLOORS, CEILINGS, SUPPORTS, STRUCTURE, ETC. TO REMAIN. K. ALL DEMOLITION MATERIALS AND DEBRIS SHALL BE DISPOSED OF ACCORDING TO FEDERAL, STATE AND LOCAL REGULATIONS. L. AT LOCATIONS WHERE EXISTING WALLS ARE TO BE REMOVED NEAR EXISTING WALLS TO REMAIN, PERFORM DEMOLITION WITHOUT DISTURBING EXISTING ELEMENTS TO REMAIN. WALLS TO REMAIN SHALL BE INTACT AND HAVE A NEAT SURFACE. M. REFER TO "ITEMS TO BE PRESERVED" LIST FOR ITEMS THAT SHALL BE SALVAGED FOR RELOCATION. VERIFY WITH OWNER FOR ON SITE STORAGE LOCATION OF SALVAGED ITEMS. N. DAMAGED FIREPROOFING SHALL BE REPAIRED/ REPLACED TO MATCH EXISTING OR AS PER CODE. O. THE GENERAL CONTRACTOR SHALL DEMOLISH ANY EXISTING ABANDONED VOICE/DATA CABLING AND DEAD OR NON-USE ELECTRICAL LINES BACK TO PANEL. ALL RECEPTACLES NOT RE -USED ARE TO BE REMOVED, PATCHED, AND PAINTED. P. REMOVAL OF LOW VOLTAGE EQUIPMENT PERTAINING TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED BY THE OWNER. Q. LABEL ALL EXISTING ITEMS THAT ARE TO BE PRESERVED AND PROPERLY STORED FOR RE -INSTALLATION. 0 2' 4' Scale: 1/4" = T-O" RECEIVE Jul 28 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GRAPHITE Graphite Design Group, LLC 1809 7th Avenue, Suite #700 Seattle, WA 98101 206.224.3335 www.graphitedesigngroup.com OWNER MFEWAY Safeway, Inc. 1371 Orchard Blvd, #200 Walnut Creek, CA 94596 425.201.6411 CONSULTANT SEAL 9336 1 REG MARTIN LEE HILL ITEOFW 5HINGTON Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED / REVISED DATE PERMIT SET 07/15/2020 DEMOLITION FLOOR PLAN D-101 DESIGN ARCHITECT F E D C B A Q_ ICI ORELOCATION PLAN Scale: 1 /4" = V-0" KEYED NOTES 1. NEW KIOSK DATUM POINT. CN N GENERAL NOTES A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL CONTRACTOR TO IMMEDIATELY STARBUCKS PROJECT DEVELOPMENT MANAGER. B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO DEMOLITION TO REVEAL FULL SCOPE OF WORK. C. LABEL ALL EXISTING ITEMS THAT ARE TO BE PRESERVED AND PROPERLY STORED FOR RE -INSTALLATION. D. EXISTING SPRINKLERS TO REMAIN OPERATIONAL DURING CONSTRUCTION. U" n 0 2' 4' 8' ll(N Scale 1/4"=1'-0" RECEIVE Jul 28 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GRAPHITE Graphite Design Group, LLC 1809 7th Avenue, Suite #700 Seattle, WA 98101 206.224.3335 www.graphitedesigngroup.com OWNER MFEWAY Safeway, Inc. 1371 Orchard Blvd. #200 Walnut Creek, CA 94596 425.201.6411 CONSULTANT SEAL P336 I REG MARTIN LEE HILL ATE 0P WASHINGTOV Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED / REVISED DATE PERMIT SET 07/15/2020 RELOCATION PLAN D-1 02 DESIGN ARCHITECT F E D B A SPECIALTY EQUIPMENT SCHEDULE - "E" DESIGN ID I COUNT DESCRIPTION FURN. BY INST. BY COMMENTS COOLING 12618 1 FRIDGE UNDERCOUNTER 1 DOOR WITH SHELF - 271N 685MM 3PV 3PV 20011 1 FRIDGE NITRO 2 TAP JT NITCOM RH SIB 3PV KIT INCLUDES UNDERCOUNTER FRIDGE, FONT, TRAY, AND TUBING; 3PV SCHEDULE ICEE 2 WEEKS OUT EQUIPMENT 12407 1 OVEN TURBOCHEF NEXT GENERATION 3PV 3PV 19559 1 NITROGEN GENERATOR ELEMENT 3PV 3PV 19742 1 ESPRESSO MACHINE MASTRENA II SB 3PV FOOD CASE 18903 1 FOOD CASE - COUNTERTOP PASTRY 3 SHELF - 281N 710MM 3PV 3PV ICE 10348 1 ICE - BIN B40 3PV GC 10527 1 ICE - BIN DROP IN 45LB 20KG 3PV GC 19494 1 ICE - MACHINE CIM0530HT AIR COOLED TOP VENT 3PV GC OTHER 10091 1 CUP DISPENSER TALL HOT VERTICAL 3PV 3PV 10396 1 CUP DISPENSER SHORT HOT VERTICAL 3PV 3PV 10791 2 CUP DISPENSER GRANDE VENTI COLD VERTICAL 3PV 3PV 10855 2 CUP DISPENSER GRANDE VENTI HOT VERTICAL 3PV 3PV 10858 1 CUP DISPENSER TALL COLD VERTICAL 3PV 3PV 13330 1 MOBILE CUP DISPENSER CADDY 3PV 3PV 13584 1 CUP DISPENSER TRENTA COLD VERTICAL 3PV 3PV 19495 1 NITRO 2 TAP HANDLE AND BADGE KIT 3PV 3PV 19560 1 NITRO 2 TAP BADGE MOUNT FRONTBAR 3PV 3PV 20403 6 KEG - 3GAL 3PV 3PV 3PV SCHEDULE ICEE 2 WEEKS OUT TO CONNECT BEV LINE AND CO2 LINES. SBUX DM PREPARE 1 KEG OF COLD BREW AT LEAST 20 HOURS PRIOR TO ICEE CALIBRATION FLOOR TREATMENT SCHEDULE - "T" DESIGN ID I AREA DESCRIPTION FURN. BY INST. BY COMMENTS TILE 21188 782 SF VINYL FLOOR TILE - WASHED CONCRETE - GC GC GC PROVIDED; CONTACT: ALAN IRON - 24X241N 60OX600MM ROWELL at (478) 273-1046 OR AROWELL@ASPECTAFLOORING.COM; ALLOW 1-2 WEEKS LEAD TIME. INSTALL IN STACK PATTERN. 4'-6" 3 30' - 5 1 /2" F117417 F 17327 F 16520 1 � I I O / 0 A201 3 j)FURNITURE, FIXTURES, AND EQUIPMENT PLAN Scale: 1 /4" = V-0" PLUMBING FIXTURE SCHEDULE - "P" DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS FAUCET 11003 1 FAUCET - DIPPERWELL 3PV GC 3PV TO VERIFY IF EXISTING IS METERED; IF NOT, ORDER NEW FILTER 12501 1 FILTER - RO SYSTEM 6000PD 3PV 3PV GC AND 3PV TO COORDINATE FINAL WATER SYSTEM SPECIFICATIONS 13076 1 FILTER - PREFILTRATION SYSTEM 3PV 3PV GC AND 3PV TO COORDINATE FINAL WATER SYSTEM SPECIFICATIONS 13077 1 FILTER - HEAD SINGLE 3PV 3PV GC AND 3PV TO COORDINATE FINAL WATER SYSTEM SPECIFICATIONS 13078 1 FILTER - CARBON FILTER CARTRIDGE WITH 3PV 3PV GC AND 3PV TO COORDINATE SCALE REDUCTION FINAL WATER SYSTEM SPECIFICATIONS 13079 1 FILTER - HEAD TRIPLE 3PV 3PV GC AND 3PV TO COORDINATE FINAL WATER SYSTEM SPECIFICATIONS 13081 3 FILTER - CARBON FILTER CARTRIDGE 3PV 3PV GC AND 3PV TO COORDINATE FINAL WATER SYSTEM SPECIFICATIONS 13087 1 FILTER - WATER CONDITIONING CABINET 3PV 3PV GC AND 3PV TO COORDINATE FINAL WATER SYSTEM SPECIFICATIONS 13149 1 FILTER -PRESSURE GAUGE 3PV 3PV GC AND 3PV TO COORDINATE FINAL WATER SYSTEM SPECIFICATIONS FURNITURE SCHEDULE - "F" DESIGN ID COUNT DESCRIPTION FURN. BY I INST. BY COMMENTS CHAIR 17417 14 CHAIR - CAFE ANNA - DARK WARM BROWN WD0001 3PV �GC TABLE 16520 3 TABLE - BASE CAFE HEIGHT DOME ACCENT - 201N 510MM - HOT ROLLED STEEL MT0011 3PV GC 17327 3 TABLE - TOP SQUARE - 241N 610MM - WALNUT WD0077 3PV GC 19292 2 TABLE - ACCESSIBLE BASSAMFELLOWS - 48X241N 1220X610MM - WALNUT WD0077 3PV GC 3'-5" 3 E 10348 2 E 19494 io o � � o L-0 �P 12501 P 13076 4 — P 13149 7 8 I P 13077 P 13078 ^—" 0 6 A201 L P 13079 E 12618 E 12407 E 10527 P 13081 5 2 1 5 P 13087 6 r-� A101 I � I 2 A201 I I J I I E 18903 L—J 3 E 19742 1 E 19559 13 E 20011 14 A201 E 20403 3 KEYED NOTES 1. EXISTING MOD 17Ci KIOSK / LH / FREESTANDING / LARGE EXPANSION / MODK RECLAD DARK FINISH PALETTE. 2. NEW KIOSK DATUM POINT. SEE RELOCATION PLAN FOR DIMENSIONS. 3. STARBUCKS FLOORING TRANSITION. ONLY STARBUCKS MERCHANDISE AND FIXTURES TO BE WITHIN THIS AREA. 4. OWNER TO CONFIRM EXTERIOR SIGNAGE IS IN GOOD WORKING ORDER AND MEETS STARBUCKS CURRENT BRAND STANDARDS. 5. ALL EQUIPMENT TO REMAIN FOR REUSE, LION. SERVICE AND/OR REPAIR AS REQUIRED. 6. 3PV TO REINSTALL DIPPERWELL AS INDICATED. 7. EXISTING BREWER TO BE REUSED, LION. 8. EXISTING AIRPOTS TO BE REUSED, LION. 9. EXISTING GRINDER TO BE REUSED, LION. 10. EXISTING BLENDER TO BE REUSED, UON. 11. INSTALL ALL FURNITURE THROUGHOUT AS SHOWN. 12. ADA SEATING. 13. ADD ADDITIONAL RECEPTACLES AS NEEDED FOR NITRO EQUIPMENT AND AT POS FOR FUTURE CONNECT EQUIPMENT. 14. PLACEHOLDER POINT OF SALE SYSTEM PER OWNER SPECIFICATION. LICENSED STORES RESPONSIBILITY LEGEND SIB - STARBUCKS 3PV - STARBUCKS THIRD PARTY VENDOR LC - OWNER GC - OWNER'S GENERAL CONTRACTOR GENERAL NOTES A. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM UNLESS OTHERWISE NOTED. B. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND PREP AREAS SHALL HAVE A COVED BASE. C. ALL FOOD STORAGE SHALL BE AT LEAST 6" (150MM) AFF. D. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE SEALED. E. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREP AREAS SHALL BE SMOOTH, NON -TOXIC, NOW ABSORBENT, DURABLE AND EASILY CLEANABLE. PAINT SHALL BE WASHABLE AND SEMI -GLOSS OR HIGH -GLOSS FINISH. F. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION FOUNDATION STANDARDS OR EQUIVALENT. G. ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTERS, WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING. H. CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT SHEET (E.G. ICE MACHINE). I. FOR LOCATION OF COUNTERTOP EQUIPMENT, REFER TO CASEWORK ELECTRICAL DETAILS. J. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS, EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR ACCUMULATION OF DUST, DIRT AND DEBRIS. K. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR PREMIXING FAUCET. L. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. M. THIRD PARTY VENDOR (3PV) TO COORDINATE WATER TEST COLLECTION WITH OWNER, AND INSTALLATION OF WATER FILTRATION SYSTEM AS DESIGNED BY PENTAIR. N. ALL FLOORING AND BASE MATERIAL TO BE INSTALLED ACCORDING TO SPECIFICATIONS. 0. FLOORING INSIDE KIOSK TO BE SPECIFIED BY ARCHITECT OF RECORD IN ACCORDANCE WIT LOCAL JURISDICTIONAL REQUIREMENTS. 3PV (LOAD KING OR WASSERSTROM) • Contact ICEE to schedule Nitro equipment calibration min. 2 weeks prior to install and cut PO to lock in date. Some jurisdictions require calibration to be completed prior to final inspection, please verify. ICEE CONTACT INFORMATION • ICEE scheduling: 1-866-292-4233 option 2 / ICEE-STARBUCKS@ICEE.COM / ICEE- WFS@JJSNACK.COM • Request calibration for Nitro 2 Tap Compact unit at Starbucks store • Cold Brew must be correctly brewed / cooled to calibrated equipment by Operations District Manager OPERATIONS - DISTRICT MANAGER • Confirm Nitro install timing with the 3PV • Prepare and chill cold brew 2 days in advance of scheduled Nitro Compact Calibration with ICEE OWNER -GC • Run plumbing drain lines (as req by AHJ) from drip tray to the floor sink, prior to calibration ICEE • Connect gas lines from generator to nitro refrigerator • Connect beverage lines out of refrigerator to font. Connect kegs and calibrate. KIOSK INTERIOR FLOOR FINISH DIAGRAM 23' - 1 3/4" IE 113330 1 E1108551 H((► )lll(( -0 )� E113584 INTERIOR AREA: 220SF "' i11=1 IUMi;a O2 CUP CADDY DETAIL Scale: 1 1 /2" = V-0" 0 2' 4' Scale: 1/4" = 1'-0" RECEIVE Jul 28 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GRAPHITE Graphite Design Group, LLC 1809 7th Avenue, Suite #700 Seattle, WA 98101 206.224.3335 www.graphitedesigngroup.com OWNER MFEWAY Safeway, Inc. 1371 Orchard Blvd, #200 Walnut Creek, CA 94596 425.201.6411 CONSULTANT SEAL P336 I REG MARTIN LEE HILL ATE 0P WASHINGTOV Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED / REVISED DATE PERMIT SET 07/15/2020 FF&EPLAN A-101 DESIGN ARCHITECT F E D C B A CASEWORK SCHEDULE - "C" DESIGN IDI COUNT I DESCRIPTION FURN. BY INST. BY COMMENTS CABINET X5000 1 CABINET - MOD K REAR STORAGE 3PV 3PV (3) CABINETS 47.5"W X 18.5"D X 46.5"H X5005 1 ICE TOWER EXPANSION 3PV 3PV HEIGHT TO MATCH EXISTING CANOPY X5006 1 CABINET - BASE - ICE 3PV 3PV 3PV TO MODIFY DIPPER WELL LOCATION AS NEEDED TO FIT X5007 1 CABINET - UPPER 3PV 3PV 3PV TO PROVIDE ALL NEW UPPER CABINETS CAFE 20348 2 FREESTANDING 1 UNIT TALL - 181N 455MM - 3PV 3PV WALNUT WD0077 20349 2 FREESTANDING 1 UNIT TALL - 361N 915MM - 3PV 3PV WALNUT WD0077 20552 2 CASTER BASE - 361N 915MM 3PV 3PV 20635 2 FREESTANDING SHELVES 1 UNIT TALL - 181N 3PV 3PV 455MM - WALNUT WD0077 COUNTERTOP X5001 1 COUNTERTOP-POS 3PV 3PV 3PV TO REPLACE COUNTER AT POS WITH CURRENT SPEC X5002 1 COUNTERTOP - HAND-OFF 3PV 3PV 3PV TO MODIFY EXISTING HAND-OFF PLANE TO ALIGN WITH SIDE SUPPORT PANEL X5003 1 COUNTERTOP - CBE 3PV 3PV 3PV TO PROVIDE NEW COUNTERTOP AND BACKSPLASH; HEIGHT TO MATCH FRONT LINE; VERIFY SIZE PRIOR TO PRODUCTION X5004 1 COUNTERTOP - STORAGE 13PV 13PV 11 V-11" L X V-7" D X 1 1/4" H OTHER X5008 1 DIEWALL WITH SNEEZEGUARD - BREW 3PV 3PV 3PV TO EXTEND DIEWALL AT NEW BREW, CBS; LENGTH: 1'- 6", VERIFY; FINISH TO MATCH EXISTING X5009 1 DIEWALL - SIDE 3PV 3PV 3PV TO PROVIDE MODIFIED BACK ANDVERTICAL END SECTION. INCLUDES TOP CAP AND PANEL. HEIGHT TO MATCH BACK AND DIEWALL. X5010 1 PANEL - TALL STORAGE 3PV 3PV 3PV TO PROVIDE AT MODIFIED SIDE STORAGE X5011 2 SCREEN WITH PERFORATED METAL - CUSTOM 3PV GC FINISH: WD0001 AND MT0011 CW FINISH - RECLAD - ESPRESSO LOCATION DESCRIPTION FINISH CODE COMMENTS COMMON FINISH BACKBAR COUNTERTOPS AND STAINLESS STEEL REPAIR AND REPLACE AS BACKSPLASHES NEEDED CASEWORK INTERIORS AND DOORS PLASTIC LAMINATE - MOTTLED BLACK PL0019 CONDIMENT STATION FACE AND DOORS PLASTIC LAMINATE - MOTTLED BLACK PL0019 REPLACE DOORS AND HARDWARE. EDGEBANDING TO MATCH COLOR COUNTERTOPS - POS, HANDOFF PLANE, COMPOSITE - LINEN CP0028 AND CONDIMENT STATION PANELS AT CEILING ABOVE BACK BAR PLASTIC LAMINATE - WILSONART - CRISP LINEN - PLx0001 4942-38; FINE VELVET FINISH PANELS TO COVER AND SQUARE -UP METAL - URBAN BRONZE MTX001 COLOR NUMBER: SMSBZ667299Q MAPLE SIGN COLUMNS SNEEZE GUARD HARDWARE METAL - FLAT BLACK POWDERCOAT MT0028 SWING GATE IBLACK ELIASON GATE CONCEPT FINISH CASEWORK FRONTS WOOD - WALNUT - VERTICAL SLATS WD0077/MAD 101 PRIMARY LAMINATE WRAPS EXTERNAL PLASTIC LAMINATE - PIONITE - GRANDIOSE GRID PLX002 REPLACE DOORS AND KIOSK ELEMENTS HARDWARE. EDGEBANDING TO MATCH COLOR TOP CAPS COMPOSITE - LINEN CP0028 KEYED NOTES SCOPE OF WORK LISTED BELOW IS COMPRISED OF ITEMS FOUND DURING STORE ASSESSMENT. ANY ITEMS IN NEED OF REPAIR, BUT NOT MENTIONED BELOW, SHOULD ALSO BE COMPLETED DURING REFRESH 1. CASEWORK TO BE RECLAD IN SPECIFIED FINISHES. SEE CASEWORK FINISH SCHEDULE FOR SPECIFICATIONS. 2. DO NOT CAULK TRASH RINGS TO COUNTERTOPS. 3. EXISTING STARBUCKS MERCHANDISERS AND DISPLAY TO BE REUSED: • BASKETS (4) 4. 3PV TO REMOVE ALL APRONS FROM CASEWORK. 5. 3PV TO REPAIR/REPLACE BROKEN CABINET DOOR, LAMINATE EDGEBANDING, MISSING LOCKS, HINGES, AND HANDLES THROUGHOUT KIOSK. 6. 3PV TO REPLACE SNEEZEGUARDS WITH CURRENT GLASS SPECIFICATION. 7. 3PV TO CLEAN ALL CANOPY TILES; REPAIR / REPLACE ANY BROKEN OR MISSING TILES AS NEEDED. 8. NOT USED. 9. STORAGE CABINETS TO BE LOCATED AGAINST ADJACENT DELI CASE. 10. 3PV TO MODIFY EXISTING FRONTLINE CABINETS TO ALLOW SPACE FOR NITRO EQUIPMENT. 11. 3PV TO EXTEND HANDOFF PLANE AS INDICATED. GENERAL NOTES A. GENERAL CONTRACTOR TO NOTIFY STARBUCKS PROJECT DEVELOPMENT MANAGER IMMEDIATELY IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXISTING SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT CASEWORK FIXTURES. GENERAL CONTRACTOR MUST MAINTAIN ALL "HOLD" TO DIMENSIONS SHOWN ON PLANS AND SHOP DRAWINGS. B. STARBUCKS PROJECT DEVELOPMENT MANAGER TO COORDINATE AND SCHEDULE CASEWORK DELIVERY DATE. STARBUCKS PROJECT DEVELOPMENT MANAGER TO CONFIRM CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4) WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF DELIVERY. C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS NOTED OTHERWISE. D. ALL CASEWORK BOX BASES / TOE KICKS SHALL BE SET AND LEVELED USING 1/4" (6MM) NON -ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR. E. CASEWORK MANUFACTURER TO ENGINEER PROPER COUNTERTOP SUPPORT AT ESPRESSO BAR AND OTHER WORK STATIONS PER STARBUCKS MINIMUM PERFORMANCE REQUIREMENTS. E. SEE WALL FINISH PLAN FOR LOCATION, TAGGING, AND FINISH SCHEDULES OF APPLIED WALL TREATMENTS. F. SEE REFLECTED CEILING PLAN FOR CASEWORK SOFFIT LOCATIONS. G. CASEWORK VENDOR TO PROVIDE ALL SHOP DRAWINGS TO STARBUCKS DESIGN MANAGER FOR REVIEW PRIOR TO MANUFACTURE. I. REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF ELECTRICAL, DATA, AND PLUMBING ON FRONT AND BACKLINE OF BAR. J. OWNER CONTRACTS DIRECTLY WITH STARBUCKS THIRD PARTY VENDOR TO SUPPLY CASEWORK LISTED IN CASEWORK SCHEDULE, UNLESS OTHERWISE NOTED. K. STARBUCKS THIRD PARTY VENDOR TO COORDINATE AND SCHEDULE CASEWORK DELIVERY DATE. L. REFER TO UPPER CASEWORK AND MENU BOARD ATTACHEMENT DETAILS FOR INSTALLATION INFORMATON, AS REQUIRED. C X5000 C X501 k, LEGEND C X5004 C X5008 � — INDICATES STAINLESS STEEL (SST) COUNTERTOP � /� I �� J o 0 0 I L i J C X5009 INDICATES SOLID SURFACE (SS) COUNTERTOP \ 2 O O I � I \ 11 1 ° 1 �� LICENSED STORES C X5003 DO RESPONSIBILITY LEGEND 1 C X5001 10 SB - STARBUCKS \ C 20552 C 20552 3 3PV - STARBUCKS THIRD PARTY VENDOR C 20349 C 20349 C 20635 --I I� LC - OWNER �j~ 3 � II GC - OWNER'S GENERAL CONTRACTOR C 20348 C X5011 0 O E 20348 C 20635 OCASEWORK PLAN Scale: 1/4" = V-0" 3 CASEWORK VENDOR TO PROVIDE ALL SHOP DRAWINGS TO STARBUCKS DM FOR REVIEW PRIOR TO MANUFACTURE. 2 4 All( N 8 RECEIVE Scale: 1/4" = V-0" Jul 28 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GRAPHITE Graphite Design Group, LLC 1809 7th Avenue, Suite #700 Seattle, WA 98101 206.224.3335 www.graphitedesigngroup.com OWNER MFEWAY Safeway, Inc. 1371 Orchard Blvd, #200 Walnut Creek, CA 94596 425.201.6411 CONSULTANT SEAL 93361 REG MARTIN LEE HILL ATE GP WASHINGTOV Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED / REVISED DATE PERMIT SET 07/15/2020 CASEWORK PLAN A-1 02 DESIGN ARCHITECT F E D C B A GRAPHICS AND ARTWORK SCHEDULE - "G" DESIGN IDI COUNT I DESCRIPTION FURN. BY INST. BY COMMENTS GRAPHICS - INTERIOR MENU X1000 6 �DOPPIO MENU PANEL 3PV 3PV V TO PROVIDE BACKER BOARD AND PUNTING KIT SIGNAGE SCHEDULE - "S" DESIGN IDI COUNT I DESCRIPTION FURN. BY INST. BY BULB COMMENTS SIGNAGE - DISK 16130 1 SIGN - DISK BLADE ILLUMINATED WALL MOUNTED EVOLVED - 181N 455MM 3PV 3PV SIGNAGE - WORDMARK 19555 1 SIGN - WORDMARK STARBUCKS ON LOW RACEWAY - 101N 255MM 3PV 3PV WHITE OKIOSK ELEVATION - FRONT Scale: 3/8" = V-0" O4 KIOSK INTERIOR - BACKLINE scale: 3/8" = V-0" FO EO LICENSED STORES RESPONSIBILITY LEGEND SB - STARBUCKS 3PV - STARBUCKS THIRD PARTY VENDOR LC - OWNER GC - OWNER'S GENERAL CONTRACTOR 2 KIOSK ELEVATION - GATE SIDE scale: 3/8" = V-0" O5 KIOSK INTERIOR - FRONT scale: 3/8" = V-0" KEYED NOTES 1. 3PV TO MODIFY EXISTING STORAGE AS NEEDED TO ACCOMMODATE NEW CBE COUNTER. 2. 3PV TO ENGINEER MOUNTING FOR NEW MENUS. 3. EXISTING SIGNAGE TO REMAIN. 4. 3PV TO PROVIDE NEW SNEEZEGUARDS AS INDICATED. 5. RELOCATED U/C REFRIGERATOR. 6. 3PV TO MODIFY EXISTING SIDE LINE TO ACCOMMODATE NEW CBE COUNTER. 7. 3PV TO PROVIDE SUPPORT AT COUNTER AS REQUIRED. 8. CENTER NEW WORDMARK ON CANOPY. 1\ GENERAL NOTES A. FLOORS, WALL, AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL BE SMOOTH, NON -TOXIC, NON -ABSORBENT, DURABLE, AND EASILY CLEANABLE. PAINT IN THESE AREAS SHALL BE WASHABLE; SEMI -GLOSS OR HIGH GLOSS FINISH. B. CHANGE OF PAINT COLOR ONLY AT INSIDE CORNERS, UNLESS NOTED OTHERWISE. C. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL SHERWIN WILLIAMS ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE: 1) WOODS AND METAL SURFACES SHALL BE SEMI -GLOSS OR EQUAL. 2) ACCENT AND TRIM PAINTS SHALL BE SEMI -GLOSS OR EQUAL. 3) WALL AND CEILING PAINTS SHALL BE EGGSHELL OR EQUAL. 4) PAINTS IN WORKROOM RESTROOM(S) OR CAFE BAR SHALL BE SEMI -GLOSS OR EQUAL. E. REFER TO INTERIOR WALL FINISH PLAN SHEET A106 FOR PAINT SCHEDULES AND WALL FINISH SCHEDULE. F. WORKROOM TO BE FINISHED PER LOCAL CODE. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL FINISHES. G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE SEALED. H. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION AREAS SHALL HAVE A 6" COVED BASE. I. GENERAL CONTRACTOR TO INSTALL WALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING BACK BAR WALL TILE. J. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH ARTWORK / GRAPHICS FOR PROPER INSTALLATION. O3 KIOSK ELEVATION - CONDIMENT SIDE scale: 3/8" = 1'-0" O6 KIOSK INTERIOR - SIDE scale: 3/8" = V-0" 2' 4' 1ECEIVE Scale: 3/8" = 1'-0" Jul 28 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GRAPHITE Graphite Design Group, LLC 1809 7th Avenue, Suite #700 Seattle, WA 98101 206.224.3335 www.graphitedesigngroup.com OWNER MFEWAY Safeway, Inc. 1371 Orchard Blvd. #200 Walnut Creek, CA 94596 425.201.6411 CONSULTANT SEAL 9336 1 REG MARTIN LEE HILL ATE OF WASHINGTON Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED / REVISED DATE PERMIT SET 07/15/2020 INTERIOR FINISH ELEVATIONS A-201 F 2 3 N h 8 N IN DESIGN ARCHITECT 7 0 N D C 0 8 GENERAL NOTES SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. SITE EXAMINATION THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF CSA, ULC, NEC, ASTM, UL, ETL, NEMA, ANSI, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES, THE HIGHEST STANDARD SHALL APPLY. ELECTRICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS. PERMITS AND FEES THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK. WARRANTY THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. GENERAL ELECTRICAL NOTES 1. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL WORK AND SPECIFICATIONS WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING DIMENSIONS. OVERALL CASEWORK COMPONENT DIMENSIONING ON ELECTRICAL DETAILS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. 2. ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM WITHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANEL BOARD. 3. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE - ENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING LOCATED WITHIN THE DEMOLITION AREA THAT WILL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED. 4. THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:OOPM AND 5:OOAM. 5. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY CONDUIT AND J-BOXES TO SUPPORT A COMPLETE SYSTEM. COORDINATE ALL DEVICE LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECT PRIOR TO ROUGH -IN. PROVIDE END -TO -END PULL STRINGS IN ALL CONDUITS. LABEL EACH END OF THE PULL STRING WITH CONDUIT SYSTEM AND DESTINATION. PROVIDE INSULATED BUSHINGS ON ALL STUBBED -UP AND EXPOSED CONDUIT ENDS. 6. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 7. EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED WHERE NECESSARY IN EXPOSED CEILING AREAS. IF CONDUITS NEED TO BE SURFACE MOUNTED TO WALLS, COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER FOR APPROVAL. 8. VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECTURAL DRAWINGS, INTERIOR DETAILS, FINISH SCHEDULES, GENERAL CONTRACTOR, EQUIPMENT VENDORS, STARBUCKS AND EXISTING SITE CONDITIONS. VERIFY FINAL DOOR HINGE LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH LOCATION IF NEEDED. DO NOT MOUNT RECEPTACLES/SWITCHES IN LOCATIONS THAT WOULD CONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE TRANSITIONS, ETC. ABBREVIATIONS AFF ABOVE FINISHED FLOOR AHJ AUTHORITIES HAVING JURISDICTION CKT CIRCUIT CW COLD WATER CXA COMMISSIONING AGENT DN DOWN DTL DETAIL DWG(S) DRAWING(S) EA EACH EC ELECTRICAL CONTRACTOR ELEC ELECTRICAL EM EMERGENCY EXIST EXISTING EXT EXTERIOR F&I FURNISH & INSTALL FLR FLOOR FT FOOT/FEET GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND HR HOUR HVAC HEATING, VENTILATION, AIR CONDITIONING HW HOT WATER LL LANDLORD LV LOW VOLTAGE MAX MAXIMUM MC MECHANICAL CONTRACTOR MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, AND PLUMBING MFG MANUFACTURER MIN MINIMUM NL NIGHTLIGHT NTS NOT TO SCALE OCP OVERCURRENT PROTECTION REF REFERENCE REQ('D) REQUIRE(D) REV REVISION SF SQUARE FEET SHT SHEET SPECS SPECIFICATION(S) SST STAINLESS STEEL TEL TELEPHONE TEMP TEMPORARY TYP TYPICAL LINO UNLESS NOTED OTHERWISE WH WATER HEATER WP WEATHER PROOF POS \ DATA LINE NOTES STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO SUPPLY AND INSTALL CATEGORY 5e (CAT5e) LAN CABLE AND CONNECTORS FOR THE POINT OF SALE (POS) SYSTEMS. CONTRACTOR TO SCHEDULE INSTALLATION OF DATA CABLING WITH DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEAD TIME FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL INSTALLERS. AT THE START OF CONSTRUCTION, STARBUCKS CONSTRUCTION MANAGER SCHEDULES DELIVERY OF CASH REGISTER/MANAGER'S WORKSTATION EQUIPMENT AND INSTALLATION BY A POS INSTALL TECHNICIAN FOR ONE (1) MONTH PRIOR TO STORE OPEN. CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO (2) WEEKS PRIOR TO DELIVERY AND INSTALLATION DATE. EQUIPMENT IS SHIPPED DIRECTLY TO THE STORE. CONTRACTOR TO ACCEPT POS EQUIPMENT DELIVERY. DO NOT REFUSE DELIVERY. DATA CABLING TECHNICIAN TO PROVIDE ALL CAT5e LAN CABLING AND CONNECTORS FROM ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS, MANAGER'S WORKSTATION, ALL OTHER NETWORKED EQUIPMENT (CUP LABELERS, CLOVER, BUMP BAR, ETC...) AND WIRELESS ACCESS POINT TO THE DATA RACK AREA. CONTRACTOR IS TO HAVE CONDUIT WITH PULL STRING IN PLACE FOR ALL CABLE RUNS PRIOR TO CABLE INSTALL DATE. STARBUCKS NEW STORE GROUP IS RESPONSIBLE FOR COORDINATING STARBUCKS POS SYSTEMS DELIVERY AND INSTALLATION WITH THE POS VENDOR. THIS GROUP MAY BE CONTACTED AT: NEWSTORES@STARBUCKS.COM. ELECTRICAL SYMBOL LEGEND O JUNCTON BOX 0 RECEPTACLE: DUPLEX SWITCH # RECEPTACLE: QUAD M MOTION (OCCUPANCY) # RECEPTACLE: HIGH VOLTAGE SENSOR SWITCH III SWITCHBANK ® RECEPTACLE: FLOOR DUPLEX DIMMER SWITCH GROUNDING ELECTRODE CONNECTION SPEAKER NL NIGHTLIGHTING 24HR/DAY ® RECEPTACLE:DATA OS CEILING MOUNTED OCCUPANCY SENSOR LANDLORD REQUIREMENTS PRIOR TO BID: THE CONTRACTOR SHALL COORDINATE WITH LANDLORD / BUILDING OWNER FOR ANY CONSTRUCTION REQUIREMENTS / SPECIFICATONS. IF LANDLORD / BUILDING OWNER DOES HAVE REQUIREMENTS, CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH REQUIREMENTS / SPECIFICATIONS AND ADHERE TO THEM. WHERE LANDLORD / BUILDING OWNER REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE PLANS (IN THE OPINION OF THE ENGINEER). LANDLORD / BUILDING OWNER REQUIREMENTS SHALL GOVERN. SPECIFICATIONS SECTION 260519 - LOW -VOLTAGE (600V OR LESS) ELECTRICAL POWER CONDUCTORS AND CABLES 1.1 MATERIALS A. CONDUCTORS AND CABLES: 1. CONDUCTORS: COPPER. 2. CONDUCTOR INSULATION: TYPE THHN/THWN-2, TYPE XHHW-2, TYPE USE AND TYPE SO. 3. MULTICONDUCTOR CABLE: METAL -CLAD CABLE, TYPE MC WITH GROUND WIRE. 1.2 CONDUCTOR MATERIAL APPLICATIONS A. FEEDERS: COPPER. SOLID FOR NO. 10 AWG AND SMALLER; STRANDED FOR NO. 8 AWG AND LARGER. B. BRANCH CIRCUITS: COPPER. SOLID FOR NO. 12 AWG AND SMALLER; STRANDED FOR NO. 10 AWG AND LARGER, EXCEPT VFC CABLE, WHICH SHALL BE EXTRA FLEXIBLE STRANDED. 1.3 CONDUCTOR INSULATION AND MULTICONDUCTOR CABLE APPLICATIONS AND WIRING METHODS A. SERVICE ENTRANCE: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. B. EXPOSED FEEDERS: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. D. FEEDERS CONCEALED IN CONCRETE, BELOW SLABS -ON -GRADE, AND UNDERGROUND: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. E. EXPOSED BRANCH CIRCUITS, INCLUDING IN CRAWLSPACES: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. F. BRANCH CIRCUITS CONCEALED IN CEILINGS, WALLS, AND PARTITIONS: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. G. BRANCH CIRCUITS CONCEALED IN CONCRETE, BELOW SLABS -ON -GRADE, AND UNDERGROUND: TYPE THHN/THWN-2, SINGLE CONDUCTORS IN RACEWAY. H. CORD DROPS AND PORTABLE APPLIANCE CONNECTIONS: TYPE SO, HARD SERVICE CORD WITH STAINLESS -STEEL, WIRE -MESH, STRAIN RELIEF DEVICE AT TERMINATIONS TO SUIT APPLICATION. 1.4 FIELD QUALITY CONTROL A. TESTING: BY CONTRACTOR. END OF SECTION 260519 SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS 1.1 QUALITY ASSURANCE A. QUALITY STANDARD FOR GROUNDING AND BONDING MATERIALS AND EQUIPMENT: UL 467. 1.2 PRODUCTS A. INSULATED CONDUCTORS: COPPER WIRE OR CABLE. B. BARE COPPER CONDUCTORS: 1. SOLID CONDUCTORS. 2. STRANDED CONDUCTORS. 3. TINNED CONDUCTORS. 4. STRANDED BONDING CONDUCTORS. 5. COPPER TAPE BRAIDED BONDING JUMPERS. 6. TINNED -COPPER BRAIDED BONDING JUMPERS. C. CONNECTORS: BOLTED AND EXOTHERMIC -WELDED TYPE. D. GROUNDING ELECTRODES: (IF SHOWN ON PLANS) 1. GROUND RODS: COPPER -CLAD STEEL, SECTIONAL TYPE WITH GROUND WELL AND COVER. 1.3 FIELD QUALITY CONTROL A. GROUND RESISTANCE TESTING: BY CONTRACTOR -ENGAGED AGENCY. END OF SECTION 260526 SECTION 260529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS 1.1 PERFORMANCE REQUIREMENTS A. DESIGN SUPPORTS FOR MULTIPLE RACEWAYS CAPABLE OF SUPPORTING COMBINED WEIGHT OF SUPPORTED SYSTEMS AND ITS CONTENTS. B. DESIGN EQUIPMENT SUPPORTS CAPABLE OF SUPPORTING COMBINED OPERATING WEIGHT OF SUPPORTED EQUIPMENT AND CONNECTED SYSTEMS AND COMPONENTS. 1.2 PRODUCTS A. SUPPORT, ANCHORAGE, AND ATTACHMENT COMPONENTS: 1. STEEL SLOTTED SUPPORT SYSTEMS WITH METALLIC COATINGS. 2. NONMETALLIC SLOTTED SUPPORT SYSTEMS. 3. RACEWAY AND CABLE SUPPORTS. 4. STEEL AND MALLEABLE -IRON CONDUIT AND CABLE HANGERS, CLAMPS, AND ASSOCIATED ACCESSORIES. 5. SUPPORT FOR NON -ARMORED CONDUCTORS AND CABLES IN VERTICAL CONDUIT RISERS. 6. STRUCTURAL STEEL FOR FABRICATED SUPPORTS AND RESTRAINTS. 7. MOUNTING, ANCHORING, AND ATTACHMENT COMPONENTS: a. POWDER -ACTUATED FASTENERS. b. MECHANICAL -EXPANSION ANCHORS. c. CONCRETE INSERTS. d. CLAMPS FOR ATTACHMENT TO STEEL STRUCTURAL ELEMENTS. e. ALL STEEL, SPRINGHEAD TOGGLE BOLTS. f. THREADED HANGER RODS. B. FABRICATED METAL EQUIPMENT SUPPORT ASSEMBLIES: WELDED OR BOLTED STEEL SHAPES. END OF SECTION 260529 SECTION 260533 - RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 MATERIALS A. METAL CONDUITS, TUBING, AND FITTINGS: 1. GRC. 2. EMT. 3. FMC: ZINC -COATED STEEL. 4. LFMC. 5. FITTINGS: a. EMT: STEEL, SETSCREW OR COMPRESSION TYPE. b. EXPANSION FITTINGS. B. NONMETALLIC CONDUITS, TUBING, AND FITTINGS: 1. RNC. 2. FITTINGS: MATCH CONDUIT. 3. SOLVENT CEMENTS AND ADHESIVE PRIMERS SHALL HAVE A VOC CONTENT OF 510 AND 550 G/L OR LESS, RESPECTIVELY. C. METAL WIREWAYS AND AUXILIARY GUTTERS: SHEET METAL WITH HINGED COVERS. D. SURFACE METAL RACEWAYS: METAL, GALVANIZED STEEL, WITH SNAP -ON COVERS. E. BOXES, ENCLOSURES, AND CABINETS: 1. METAL OUTLET AND DEVICE BOXES: FERROUS ALLOY 2. METAL FLOOR BOXES: CAST METAL OR SHEET METAL, FULLY ADJUSTABLE. 3. LUMINAIRE OUTLET BOXES: NONADJUSTABLE, DESIGNED FOR ATTACHMENT OF LUMINAIRE WEIGHING 50 LB (23 KG). 4. SMALL SHEET METAL PULL AND JUNCTION BOXES. 5. CAST -METAL ACCESS, PULL, AND JUNCTION BOXES. 6. BOX EXTENSIONS. 7. GANGABLE BOXES ARE PROHIBITED. 8. HINGED -COVER ENCLOSURES: METAL. 9. CABINETS: GALVANIZED STEEL. 1.2 RACEWAY APPLICATION A. OUTDOORS: 1. EXPOSED: GRC. 2. CONCEALED, ABOVEGROUND: RNC, TYPE EPC-40-PVC. 3. UNDERGROUND: RNC, TYPE EPC-40-PVC, DIRECT BURIED. 4. CONNECTION TO VIBRATING EQUIPMENT: LFMC. 5. BOXES AND ENCLOSURES, ABOVEGROUND: TYPE 3R OR TYPE 4. B. INDOORS: 1. EXPOSED, NOT SUBJECT TO PHYSICAL DAMAGE: GRC. 2. EXPOSED, NOT SUBJECT TO SEVERE PHYSICAL DAMAGE: EMT. 3. CONCEALED: EMT. 4. CONNECTION TO VIBRATING EQUIPMENT: FMC, EXCEPT LFMC IN DAMP OR WET LOCATIONS. 5. DAMP OR WET LOCATIONS: GRC. 6. BOXES AND ENCLOSURES: TYPE 1, EXCEPT TYPE 4 NONMETALLIC IN DAMP OR WET LOCATIONS. C. MINIMUM RACEWAY SIZE: 1/2-INCH (16-MM) TRADE SIZE. D. RACEWAY FITTINGS: COMPATIBLE WITH RACEWAYS AND SUITABLE FOR USE AND LOCATION. 1. RIGID AND INTERMEDIATE STEEL CONDUIT: THREADED RIGID STEEL CONDUIT FITTINGS. 2. PVC EXTERNALLY COATED, RIGID STEEL CONDUITS: FITTINGS LISTED FOR USE WITH THIS TYPE OF CONDUIT. 3. EMT: SETSCREW STEEL FITTINGS. 4. FLEXIBLE CONDUIT: FITTINGS LISTED FOR USE WITH FLEXIBLE CONDUIT. END OF SECTION 260533 SECTION 260544 - SLEEVES AND SLEEVE SEALS FOR ELECTRICAL RACEWAYS AND CABLING 1.1 MATERIALS A. SLEEVES: 1. SCHEDULE 40 STEEL PIPE. 2. CAST-IRON PIPE. 3. GALVANIZED -STEEL SHEET FOR CONDUITS PENETRATING NON -FIRE -RATED GYPSUM -BOARD ASSEMBLIES. 4. MOLDED -PE OR -PP PIPE. 5. GALVANIZED -STEEL SHEET FOR RECTANGULAR OPENINGS. B. SLEEVE -SEALS: 1. EPDM RUBBER SEALING ELEMENTS. 2. CARBON -STEEL PRESSURE PLATES. 3. CARBON -STEEL, WITH CORROSION -RESISTANT COATING CONNECTING BOLTS AND NUTS. C. HYDRAULIC -CEMENT GROUT. D. SILICONE SEALANTS: 1. SINGLE -COMPONENT, SILICONE -BASED, NEUTRAL -CURING ELASTOMERIC SEALANT. 2. MULTICOMPONENT, SILICONE -BASED LIQUID ELASTOMERIC NONSHRINKING FOAM. 3. VOC CONTENT OF 250 G/L OR LESS. END OF SECTION 260544 SECTION 260553 - IDENTIFICATION FOR ELECTRICAL SYSTEMS 1.1 QUALITY ASSURANCE A. COMPLY WITH ANSI A13.1 AND IEEE C2. 1.2 PRODUCTS A. POWER AND CONTROL RACEWAY IDENTIFICATION: VINYL LABELS. B. POWER AND CONTROL CABLE IDENTIFICATION: VINYL LABELS. C. CONDUCTOR IDENTIFICATION: COLOR -CODING CONDUCTOR TAPE, SELF-ADHESIVE, SELF -LAMINATING POLYESTER LABELS. D. FLOOR MARKING TAPE: 2-INCH- (50-MM-) WIDE PRESSURE -SENSITIVE VINYL TAPE. F. WARNING LABELS AND SIGNS:SELF-ADHESIVE WARNING LABELS. G. INSTRUCTION SIGNS:ENGRAVED, LAMINATED ACRYLIC OR MELAMINE PLASTIC. H. EQUIPMENT IDENTIFICATION LABELS:ENGRAVED, LAMINATED ACRYLIC OR MELAMINE PLASTIC. END OF SECTION 260553 SECTION 262416 - PANELBOARDS (IF SHOWN ON PLANS) 1.1 QUALITY ASSURANCE A. MANUFACTURER QUALIFICATIONS: ISO 9001 OR 9002 CERTIFIED. 1.2 PRODUCTS A. GENERAL REQUIREMENTS FOR PANELBOARDS: 1. CONSTRUCTED TO WITHSTAND SEISMIC FORCES. 2. ENCLOSURES: SURFACE MOUNTED. a. FRONT: HINGED COVER WITH KEY LOCK. b. OPTIONAL ENCLOSURE FEATURES: SKIRT FOR SURFACE -MOUNTED PANELBOARDS. c. DIRECTORY CARD. 3. INCOMING MAINS: CONVERTIBLE BETWEEN TOP AND BOTTOM. 4. PHASE, NEUTRAL AND GROUND BUSES: TIN-PLATED COPPER. 5. CONDUCTOR CONNECTORS: a. MATERIAL: TIN-PLATED COPPER. b. MAIN AND NEUTRAL LUGS: MECHANICAL TYPE. c. FEED -THROUGH LUGS: MECHANICAL TYPE. 6. PERCENTAGE OF FUTURE SPACE CAPACITY: FIFTEEN PERCENT. 7. SERVICE EQUIPMENT LABEL FOR PANELBOARDS INCORPORATING ONE OR MORE MAIN SERVICE DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES. B. PANELBOARD OR LOAD CENTER SHORT-CIRCUIT CURRENT RATING: FULLY RATED TO INTERRUPT SYMMETRICAL SHORT-CIRCUIT CURRENT AVAILABLE AT TERMINALS. LISTED SERIES RATED SYSTEM MAY BE USED IF APPROVED BY FOR TO LIMIT FAULT TO BELOW 22K AIC FOR GFI BREAKERS. 1. MAINS: LUGS ONLY. 3. BRANCH OVERCURRENT PROTECTIVE DEVICES FOR CIRCUIT -BREAKER FRAME SIZES LARGER THAN 125 A: BOLT -ON CIRCUIT BREAKERS. C. LIGHTING AND APPLIANCE BRANCH -CIRCUIT PANELBOARDS: 1. MAINS: LUGS ONLY. 2. BRANCH OVERCURRENT PROTECTIVE DEVICES: PLUG-IN CIRCUIT -BREAKER TYPE. 3. DOORS: CONCEALED HINGE. D. LOAD CENTERS: 1. MAINS: LUGS ONLY. 2. BRANCH CIRCUIT BREAKERS: PLUG-IN. 3. DOORS: CONCEALED HINGE. 4. CONDUCTOR CONNECTORS: MECHANICAL TYPE. E. DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES: 1. CIRCUIT BREAKERS: ADJUSTABLE INSTANTANEOUS -TRIP GFCI TYPES. 2. GFI CIRCUIT BREAKERS: RATED FOR PERSONNEL. 3. AFCI CIRCUIT BREAKERS: AS REQUIRED BY CODE. 4. OPTIONS AND TYPES AS NEEDED. F. IDENTIFICATION: 1. PANELBOARD LABELS: MANUFACTURER'S NAME AND TRADEMARK, VOLTAGE, AMPERAGE, NUMBER OF PHASES, ARC FLASH HAZARD, AND NUMBER OF POLES SHALL BE LOCATED ON THE INTERIOR OF THE PANELBOARD DOOR. 2. BREAKER LABELS: FACEPLATE SHALL LIST CURRENT RATING, UL AND IEC CERTIFICATION STANDARDS, AND AIC RATING. 3. CIRCUIT DIRECTORY: DIRECTORY CARD INSIDE PANELBOARD DOOR, MOUNTED IN TRANSPARENT CARD HOLDER. G. ACCESSORIES: 1. ACCESSORY SET INCLUDING TOOLS. 2. PORTABLE TEST SET: FOR TESTING FUNCTIONS OF SOLID-STATE TRIP DEVICES WITHOUT REMOVING FROM PANELBOARD. 1.3 FIELD QUALITY CONTROL A. TESTING: BY CONTRACTOR. END OF SECTION 262416 SECTION 262726 - WIRING DEVICES 1.1 PRODUCTS A. RECEPTACLES: DUPLEX, 125 V, 20 A. 1. STRAIGHT BLADE: CONVENIENCE AND ISOLATED GROUND. 2. GFCI: FEED THROUGH. 3. TWIST -LOCKING TYPE WITH ISOLATED -GROUND TERMINAL. B. PENDANT CORD -CONNECTOR DEVICES WITH EXTERNAL CABLE GRIP. C. CORD AND PLUG SETS: MATCH VOLTAGE AND CURRENT RATINGS AND NUMBER OF CONDUCTORS TO REQUIREMENTS OF EQUIPMENT BEING CONNECTED. D. TOGGLE SWITCHES: 120/277 V, 20 A. 1. PILOT -LIGHT SWITCHES. 2. KEY -OPERATED SWITCHES. E. WALL -BOX DIMMERS: 1. MODULAR, FULL -WAVE, SOLID-STATE UNITS WITH SLIDER CONTROL. a. INCANDESCENT: SOFT TAP OR OTHER QUIET SWITCH; EMI/RFI FILTER TO ELIMINATE INTERFERENCE. b. FLUORESCENT: TRIM POTENTIOMETER FOR LOW -END DIMMING. c. LED: COMPATIBLE WITH LED DRIVER OR LAMP. F. WALL PLATES: 1. MATERIAL FOR WORKROOM: THERMOPLASTIC WITH COLOR PER STARBUCKS. 2. MATERIAL FOR BAR: SATIN -FINISHED STAINLESS STEEL. 3. MATERIAL FOR CUSTOMER AREAS: THERMOPLASTIC WITH COLOR PER STARBUCKS. G. FLOOR SERVICE FITTINGS (IF SHOWN ON PLANS): MODULAR, (DUAL SERVICE IF NEEDED), WITH POWER RECEPTACLE (AND VOICE AND DATA COMMUNICATION OUTLET IF NEEDED). 1. TYPE: FLUSH. 2. SERVICE PLATE: RECTANGULAR. 3. VOICE AND DATA COMMUNICATION OUTLET: TWO MODULAR, KEYED, RJ-45 JACKS. H. POKE -THROUGH ASSEMBLIES (IF SHOWN ON PLANS): BELOW -FLOOR JUNCTION BOX WITH MULTICHANNELED, THROUGH -FLOOR RACEWAY/FIRESTOP AND DETACHABLE FLOOR SERVICE -OUTLET ASSEMBLY. 1. SERVICE -OUTLET ASSEMBLY: SURFACE TYPE. 2. SIZE: 3 INCHES (75 MM). I. MULTIOUTLET ASSEMBLIES (IF SHOWN ON PLANS): MANUFACTURED AND LISTED METAL RACEWAYS. J. SERVICE POLES (IF SHOWN ON PLANS): TO EXTEND POWER AND VOICE AND DATA COMMUNICATION WIRING FROM DISTRIBUTION WIRING IN CEILING TO DEVICES OR OUTLETS IN POLE NEAR FLOOR. 1. FINISH: ANODIZED ALUMINUM. 2. POWER RECEPTACLES: TWO, DUPLEX, 20 A. 3. VOICE AND DATA COMMUNICATION OUTLETS: TWO CATEGORY 5E JACKS. K. FINISHES: 1. CONNECTED TO NORMAL POWER SYSTEM: COLOR TO MATCH WALL PLATE. 2. CONNECTED TO EMERGENCY POWER SYSTEM: RED. 3. ISOLATED -GROUND RECEPTACLES: ORANGE. END OF SECTION 262726 SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS (IF SHOWN ON THE PLANS) 1.1 PRODUCTS A. FUSIBLE SWITCHES: 1. GENERAL DUTY, SINGLE THROW, [240-V] [600V] AC, 800 A AND SMALLER: UL 98 AND NEMA KS 1/NEMA 3R, TYPE GD. 2. ACCESSORIES: a. EQUIPMENT GROUND KIT. b. NEUTRAL KIT. c. ISOLATED GROUND KIT. d. CLASS R FUSE KIT. e. AUXILIARY CONTACT KIT. f. HOOKSTICK HANDLE. g. LUGS: MECHANICAL. h. SERVICE -RATED SWITCHES. i. ACCESSORY CONTROL POWER. B. NONFUSIBLE SWITCHES: 1. GENERAL DUTY, SINGLE THROW, [240-V] [600V] AC, 600 A AND SMALLER: UL 98 AND NEMA KS 1/NEMA 3R, TYPE GD. 2. ACCESSORIES: a. EQUIPMENT GROUND KIT. b. NEUTRAL KIT. c. ISOLATED GROUND KIT. c. AUXILIARY CONTACT KIT. e. HOOKSTICK HANDLE. f. LUGS: MECHANICAL. g. ACCESSORY CONTROL POWER. C. MOLDED -CASE CIRCUIT BREAKERS: 1. THERMAL -MAGNETIC TYPE. 2. ADJUSTABLE INSTANTANEOUS -TRIP TYPE. 3. ELECTRONIC -TRIP TYPE. 4. CURRENT -LIMITING TYPE. 5. INTEGRALLY FUSED TYPE. 6. GFCI TYPE. 7. GFEP TYPE. 8. FEATURES AND ACCESSORIES: a. LUGS: MECHANICAL. b. TYPE SWD FOR SWITCHING FLUORESCENT LIGHTING LOADS. c. TYPE HID FOR FEEDING FLUORESCENT AND HIGH -INTENSITY DISCHARGE LIGHTING CIRCUITS. d. GROUND -FAULT PROTECTION: INTEGRALLY MOUNTED, SELF -POWERED TYPE. e. SHUNT TRIP. f. UNDERVOLTAGE TRIP: 35 TO 75 PERCENT OF RATED VOLTAGE WITHOUT INTENTIONAL TIME DELAY. g. AUXILIARY CONTACTS:ONE SPDT SWITCH. h. ALARM SWITCH: ONE NC CONTACT. i. KEY INTERLOCK KIT. j. ZONE -SELECTIVE INTERLOCKING: INTEGRAL WITH GROUND -FAULT TRIP. k. ELECTRICAL OPERATOR. I. ACCESSORY CONTROL POWER. D. MOLDED -CASE SWITCHES: 1. MCCB WITH FIXED, HIGH -SET INSTANTANEOUS TRIP ONLY, AND SHORT-CIRCUIT WITHSTAND RATING EQUAL TO EQUIVALENT BREAKER FRAME SIZE INTERRUPTING RATING. 2. FEATURES AND ACCESSORIES: a. LUGS: MECHANICAL. b. GROUND -FAULT PROTECTION: REMOTE -MOUNTED AND POWERED TYPE. c. SHUNT TRIP. d. UNDERVOLTAGE TRIP: 35 TO 75 PERCENT OF RATED VOLTAGE WITHOUT INTENTIONAL TIME DELAY. e. AUXILIARY CONTACTS:ONE SPDT SWITCH. f. ALARM SWITCH: ONE NC CONTACT. g. KEY INTERLOCK KIT. h. ZONE -SELECTIVE INTERLOCKING: INTEGRAL WITH REMOTE GROUND -FAULT TRIP UNIT. i. ELECTRICAL OPERATOR. j. ACCESSORY CONTROL POWER. E. ENCLOSURES: 1. INDOOR, DRY AND CLEAN LOCATIONS: NEMA 250, TYPE 1. 2. OUTDOOR LOCATIONS: NEMA 250, TYPE 3R. 1.2 FIELD QUALITY CONTROL A. TESTING: BY CONTRACTOR. 1.3 ADJUSTING A. SET FIELD -ADJUSTABLE CIRCUIT -BREAKER TRIP RANGES. END OF SECTION 262816 RECEIVE Jul 28 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT GRAPHITE Graphite Design Group, LLC 1809 7th Avenue, Suite #700 Seattle, WA 98101 206,224.3335 www.graphitedesigngroup.com OWNER SAFEWM Safeway, Inc. 1371 Orchard Blvd. #200 Walnut Creek, CA 94596 425.201,6411 CONSULTANT H A R G I S mechanical 1201 third avenue, suite 600 electrons telecommunicationsseattle, washington 98101 I security energy t 206.448.3376 w hargis.biz SEAL 20 Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED / REVISED DATE PERMIT SET 07/15/2020 ELECTRICAL NOTES AND SPECIFICATIONS E-000 1 L_ I F IN 3 0 6 6 7 3 9 10 DESIGN ARCHITECT 11 E D 3 B A KIOSK IS TO BE REPLACED WITH A NEW KIOSK IN A SHIFTED LOCATION. DISCONNECT EXISTING EQUIPMENT AND ALL ELECTRICAL AS NECCESSARY FOR DEMOLITION OF EXISTING KIOSK. RECONNECT IN NEW LOCATION SO KIOSK IS FULLY OPERATIONAL. EQUIPMENT SCHEDULE DESIGN ID DESCRIPTION CIRCUIT BRANCH CIRCUIT REQUIRED 19742 ESPRESSO MACHINE MASTRENA A-1,3 2#6, 1#10G, 3/4"C 10267 1 DOOR UNDERCOUNTER FRIDGE A-5 2#12, 1#12G, 3/4"C 10267 1 DOOR UNDERCOUNTER FRIDGE A-5 2#12, 1#12G, 3/4"C 18903 FOODCASE A-7 2#12, 1#12G, 3/4"C 19559 NITROGEN GENERATOR ELEMENT A-9 2#12, 1#12G, 3/4"C 20010 NITRO FRIDGE A-9 2#12, 1#12G, 3/4"C X1043 R.O. WATER SYSTEM A-11 2#12, 1#12G, 3/4"C 19494 ICE MACHINE A-13 2#12, 1#12G, 3/4"C X1324 WATER HEATER A-2,4,6 4#8, 1#10G, 3/4"C 12407 WARMING OVEN A-8,10 2#8, 1#10G, 3/4"C 10746 BREWER A-12,14 3#6, 1#10G, 3/4"C 12508 BLENDER A-16 2#12, 1#12G, 3/4"C 10267 1 DOOR UNDERCOUNTER FRIDGE A-20 2#12, 1#12G, 3/4"C 12618 UNDERCOUNTER FRIDGE A-20 2#12, 1#12G, 3/4"C X3000 DIGITAL MENU BOARD A-22 2#12, 1#12G, 3/4"C 10808 GRINDER A-24 2#12, 1#12G, 3/4"C SHEET NOTES 1. REPLACE EXISTING FEEDER AND UPSTREAM BREAKER/DISCONNECT WITH NEW, RATED AT 200 AMPS. REPLACE EXISTING 100 AMP BREAKER CURRENTLY SERVING THE EXISTING KIOSK PANELBOARD WITH NEW 200 AMP, 3-POLE BREAKER AND MATCH EXISTING AIC RATING. REVISE THE EXISTING FEEDER (REUSE THE EXISTING FEEDER CONDUIT IF POSSIBLE) TO 200 AMP RATED FEEDER, 2.5"C., 4#3/0 CU, 1#6 GND. ALSO, TAKE CONTINUOUS 30-DAY AMPERE MEASUREMENT OF SERVING PANEL USING A DATA LOGGER AND SUBMIT READINGS TO THE ENGINEER OF RECORD FOR REVIEW. 2. SWITCHES FOR LIGHTING INTEGRAL TO MODULAR KIOSK SYSTEM. FURNISH AND INSTALL (1) SWITCH FOR CIRCUIT A-21 a, (1) SWITCH FOR CIRCUIT A-21 b, AND (1) SWITCH FOR CIRCUIT A-23. 3. PANEL PROVIDED WITH KIOSK. MAINTAIN AN ACCESSIBLE AREA WITH NEC WORKING CLEARANCES, 36" IN FRONT OF PANEL WITH 30" SHOULDER WORKING CLEARANCE. ELECTRICAL DESIGN PLAN NOTES A. PROVIDE ALL BRANCH CIRCUITING AND DEVICES, EVEN IF NOT SHOWN. PROVIDE ALL WIRING AND QUANTITIES TO ACCOMPLISH CIRCUITING TO MEET ALL REQUIREMENTS AND APPLICABLE CODES. B. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING ALL VOLTAGE REQUIREMENTS ON ALL EQUIPMENT AND PROVIDING BUCK -BOOST TRANSFORMERS AS MAY BE NEEDED FOR CODE. ALL ARE NOT NECESSARILY INDICATED. C. GROUND FAULT CIRCUIT INTERRUPTER (GFCI) BREAKERS (NOT RECEPTACLES) SHALL BE UTILIZED WHERE REQUIRED BY CODE AND AT ANY FLOOR BOXES. PROVIDE DEDICATED NEUTRAL WIRE FOR ALL THESE CIRCUITS. D. ALL LIGHT FIXTURES SHALL HAVE SHATTERPROOF LAMPS IF THE FIXTURE IS NOT LENSED. E. FOR NEW PANELBOARDS, CONTRACTOR TO PROVIDE ARC FLASH AND FAULT CALCULATIONS AND PROVIDE ARC FLASH LABELS ON ELECTRICAL EQUIPMENT PER N.E.C. AND LOCAL JURISDICTION. CONTRACTOR SHALL PROVIDE EQUIPMENT RATED FOR AVAILABLE FAULT CURRENT. F. NEW BREAKERS SHALL MATCH EXISTING BREAKER TYPE AND AIC RATING OF PANELBOARD. CONTRACTOR SHALL VERIFY THAT EXISTING PANELBOARD HAS SPARE CAPACITY TO HANDLE ADDITIONAL LOAD. IN THE EVENT THAT THE EXISTING PANEL CANNOT HANDLE THE ADDED LOAD, CONTACT THE ENGINEER OF RECORD PRIOR TO COMMENCMENT OF WORK. G. FOR NEW EQUIPMENT PROVIDE BRANCH (CONCEALED WITHIN CASEWORK) FROM DEVICE/EQUIPMENT INDICATED TO EXISTING PANELBOARD. PROVIDE NEW BREAKER(S) AT EXISTING SPACE OR RECONFIGURE EXISTING SPARE BREAKERS TO ACCOMODATE NEW LOAD. PANEL SCHEDULE: 06/24/2020 PANEL'A' PROJECT: Starbucks Kiosk Edmonds 1297 CLASSIFICATION: NORMAL FED FROM: MOUNTING: FIELD VERIFY VOLTAGE: 208Y/120V 30, 4-WIRE MAINS: 200A MAIN LUGS ONLY NEUTRAL: 100% RATED SECTION: 1 OF 1 NOTE ITEM DESCRIPTION CKT NO. BREAKER LOAD (VA) O LOAD (VA) BREAKER CKT NO. ITEM DESCRIPTION NOT AMP POLE AMP POLE GFI ESPRESSO MACHINE 1 40 2 3145 A 4799 50 3 2 WATER HEATER GFI GFI 3 - - 3145 B 4799 - - 4 GFI GFI REFRIGERATOR 5 20 1 1000 C 4799 - - 6 GFI GFI FOODCASE 7 20 1 1480 A 3000 30 2 8 WARMING OVEN GFI GFI INITRO GENERATOR / FRIDGE 9 20 1 1080 B 3000 - - 10 GFI GFI R.O. SYSTEM 11 20 1 1 360 C 2050 30 1 2 12 COFFEE BREWER GFI GFI ICE MACHINE 13 20 1 1900 A 2050 - - 14 GFI SPARE 15 20 1 B 1000 20 1 16 BLENDER GFI SPARE 17 20 1 1 C 20 1 18 SPARE GFI POS MISC 19 20 1 1 720 Al1000 20 1 20 REFRIGERATOR GFI TRACK LIGHTS 1 21 20 1 500 IBI 360 20 1 22 MENU BOARDS LIGHTING 1 23 20 1 1 1 500 ICI 1500 1 20 1 1 24 GRINDER GFI LOAD CALCULATIONS LOAD DESCRIPTION CONN. (VA) DEMAND FACTOR CALC. (VA) MISCELLANEOUS CONTINUOUS: EQUIPMENT & MISCELLANEOUS: LIGHTING: LARGEST MOTOR: MOTORS: RECEPTACLE: RECEPTACLES OVER 10kVA: APPLIANCE: KITCHEN (EQUIP = 9): TOTALS:l - 1000 - - 3340 - 14397 23450 125% 100% 125% 125% 100% 100% 50% 100% 65% - 1250 - - 3340 - 14397 15243 LOAD SUMMARY TOTAL CONNECTED LOAD AMPS PHASE A: 18,094 VA 151 A PHASE B: 13,884 VA 116 A PHASE C: 10,209 VA 85 A TOTAL CALCULATED LOAD: 34,230 VA TOTAL CALCULATED AMPS: 95 A 42,187 34,230 NOTES: 1. 2. 3. 4. 5. HARGIS ENGINEERS, INC. 1201 THIRD AVENUE, SUITE 600 SEATTLE, WA 98101 PH. (206) 448-3376 FAX. (206) 448-4450 0 2' 4' Scale: 1/4" = 1'-0" 0 RECEIVE Jul 28 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Q A P H I T E Graphite Design Group, LLC 1809 7th Avenue, Suite #700 Seattle, WA 98101 206.224.3335 www.graphitedesigngroup.com OWNER SAFEWM Safeway, Inc. 1371 Orchard Blvd. #200 Walnut Creek, CA 94596 425.201.6411 CONSULTANT H A R G I S mechanical 1201 third avenue, sulte 600 eiectdcal seattle, washington 98101 telecommunications seamy energy t 206.448.3376 w hargis.biz SEAL 20 Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED / REVISED DATE PERMIT SET 07/15/2020 ELECTRICAL DESIGN PLAN E-1 101 F 1 2 3 5 6 7 B 9 10 DESIGN ARCHITECT r� I� 0 C 0 A ABBREVIATIONS AFF ABOVE FINISHED FLOOR AHJ AUTHORITIES HAVING JURISDICTION APPROX APPROXIMATE BLDG BUILDING CLG CEILING CONST CONSTRUCTION CW DOMESTIC COLD WATER CXA COMMISSIONING AGENT DEG DEGREES DN DOWN DTL DETAIL DWG(S) DRAWING(S) EA EACH EC ELECTRICAL CONTRACTOR ELEC ELECTRICAL EMER EMERGENCY EXIST EXISTING EXT EXTERIOR FD FLOOR DRAIN FS FLOOR SINK F&I FURNISH & INSTALL FLR FLOOR FT FOOT/FEET FCO FLOOR CLEANOUT GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GW GREASE WASTE HR HOUR HVAC HEATING, VENTILATION, AND AIR CONDITIONING HW HOT WATER HS HANDSINK HWS HOT WATER SUPPLY HWR HOT WATER RETURN LC LICENSEE LL LANDLORD LV LOW VOLTAGE MAX MAXIMUM MC MECHANICAL CONTRACTOR MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, AND PLUMBING MFG MANUFACTURER MIN MINIMUM MS MOP SINK NL NIGHTLIGHT NTS NOT TO SCALE PC PLUMBING CONTRACTOR PS PREP SINK POC POINT OF CONNECTION REF REFERENCE REQ'D REQUIRED REV REVISION SHT SHEET SF SQUAREFEET SPECS SPECIFICATION(S) SST STAINLESS STEEL TEL TELEPHONE TEMP TEMPORARY TMV TEMPERATURE MIXING VALVE TW TEMPERED HOT WATER TYP TYPICAL 1�-�I�►11 W SANITARY WASTE WCO WALL CLEANOUT WH WATER HEATER WP WEATHER PROOF 3PV 3RD PARTY VENDOR PLUMBING FIXTURES WATER FILTRATION STARBUCKS WATER FILTRATION VENDOR WILL PROVIDE FILTRATION SYSTEM. CONTRACTOR SHALL CONFIRM WITH STARBUCKS CONSTRUCTION MANAGER WHETHER VENDOR OR PLUMBING CONTRACTOR IS TO INSTALL FILTRATION SYSTEM. PROVIDE AND COORDINATE INSTALLATION COMPLETE WITH ALL PIPING, FITTINGS, AND EQUIPMENT AS INDICATED ON THE DRAWINGS. CONNECTIONS THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT INCLUDING REQUIRED MATERIAL SUCH AS PIPING, VALVES, FILTERS, TRAPS, CHECKS VALVES, VACUUM BREAKERS, AND FLEXIBLE AND RIGID TUBING. SCHEDULES REFER TO SCHEDULES ON DRAWINGS FOR A DESCRIPTION OF LISTED ITEMS AND FURNISH ANY AND ALL PLUMBING FIXTURES LISTED AS "GC". ANY DISCREPANCIES ABOUT WHO IS TO PROVIDE PLUMBING FIXTURES IN THE SCHEDULE SHALL BE BROUGHT TO STARBUCKS ATTENTION FOR CLARIFICATION. INSTALL ALL FIXTURES LISTED REGARDLESS OF WHO SUPPLIES. HAND SINK IF FAUCET HAS A TEMPERATURE LIMIT STOP, IT IS TO BE REMOVED SO THAT TEMPERED WATER FROM THE WATER HEATER IS NOT FURTHER REDUCED. HOT WATER 100° - 110- F (34° - 43° C) MUST BE ABLE TO REACH SINK WITHIN 15 SECONDS. LANDLORD REQUIREMENTS PRIOR TO BID: THE CONTRACTOR SHALL COORDINATE WITH LANDLORD / BUILDING OWNER FOR ANY CONSTRUCTION REQUIREMENTS / SPECIFICATONS. IF LANDLORD / BUILDING OWNER DOES HAVE REQUIREMENTS, CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH REQUIREMENTS / SPECIFICATIONS AND ADHERE TO THEM. WHERE LANDLORD / BUILDING OWNER REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE PLANS (IN THE OPINION OF THE ENGINEER). LANDLORD / BUILDING OWNER REQUIREMENTS SHALL GOVERN. PLUMBING SYMBOL LEGEND GW CD CWF CWN CWS TW RO G RD RS SORW SORW V GW CD CW HW CWF CWN CWS TW RO G RD RS SANITARY OR WASTE PIPING ABOVE SLAB SANITARY OR WASTE PIPING BELOW SLAB VENT PIPING GREASE WASTE CONDENSATE DRAIN COLD WATER PIPING HOT WATER PIPING COLD WATER FILTERED COLD WATER NANO FILTERED COLD WATER SOFTENED TEMPERED WATER REVERSE OSMOSIS WATER GAS PIPING REFRIGERANT DISCHARGE PIPING REFRIGERANT SUCTION PIPING BV BALL VALVE GV GATE VALVE CH. V CHECK VALVE RV RELIEF VALVE aHB HOSE BIBB SHOCK ABSORBER STRAINER WCO WALL CLEANOUT FCO FLOOR CLEANOUT ® FS FLOOR SINK FEI WM WATER METER ® POC CONNECT TO EXISTING GENERAL NOTES SCOPE THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL PLUMBING SYSTEM. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, AND EQUIPMENT RELATED TO THE INSTALLATION OF THE PLUMBING WORK. SITE EXAMINATION THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE PLUMBING WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE APPROPRIATE PROVISIONS OF CSA, ULC, ASME, ASTM, UL, NEMA, ANSI, ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE/PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO THE OWNER. PERMITS AND FEES THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE PLUMBING WORK. WARRANTY THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. GENERAL PLUMBING NOTES 1. PLUMBING CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF WORK. 2. EXPOSED/SURFACE MOUNTED PIPING IS ONLY ALLOWED IN THE BAR AREA UNDER COUNTERTOPS, WHERE IT DOES NOT OBSTRUCT CABINETS/DEVICES AND WHERE APPROVED BY THE ARCHITECT. IF ROUTED THROUGH CABINETS, IT SHALL BE ROUTED TO MAXIMIZE STORAGE SPACE AND BE PROTECTED FROM DAMAGE. 3. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR ARRANGEMENT OF SYSTEM(S). FURNISH AND INSTALL ALL COMPONENTS NEEDED WHETHER INDICATED OR NOT TO PROVIDE A COMPLETE AND OPERATING SYSTEM. OVERALL CASEWORK COMPONENT DIMENSIONING ON PLUMBING DETAILS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. 4. CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES, AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM FROM ACTUAL BUILDING DIMENSIONS. 5. THE PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING WORK WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR FIXTURES IN CASEWORK AND PLUMBING DETAILS. 6. ALL PIPING AND/OR PLUMBING DEVICES SHALL BE SUPPORTED FROM STRUCTURE (NOT FROM HVAC DUCTS OR OTHER PIPES/CONDUITS). 7. CONDITIONED WATER: EITHER R.O., FILTERED OR SOFTENED PER RECOMMENDATION OF FILTER MANUFACTURER & STARBUCKS. 8. CONFIRM PIPING CONNECTIONS TO ALL WATER TREATMENT SYSTEMS (LAURENCE.PINKERTON@PENTAIR.COM, CONTACT @ 310-292-9080). VALVES GENERAL PLUMBING CONTRACTOR TO PROVIDE VALVES WHERE INDICATED ON PLANS AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. SEE SPECIFICATIONS FOR TYPES. INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE NOTED) BETWEEN VALVE AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO EQUIPMENT FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT MOVING EQUIPMENT. SHUT OFF VALVES TO BE BALL TYPE. VALVES SHALL BE LISTED/APPROVED FOR USE PER AUTHORITIES HAVING JURISDICTION (AHJ) AND CODE REQUIREMENTS. PROVIDE VALVE IDENTIFICATION PER THE SPECIFICATIONS FOR MAIN WATER SERVICE SHUT-OFF AND ANY OTHER VALVES WHICH ARE NOT CLEARLY EVIDENT WHAT THEY SERVE. SUPPLY WATER SERVICE IF WATER PRESSURE SUPPLIED TO STORE IS GREATER THAN 65 PSI, PROVIDE A PRESSURE REGULATOR IN MAIN SUPPLY TO REDUCE WATER PRESSURE. PROVIDE BACKFLOW PREVENTION ON WATER SERVICE IF REQUIRED BY LOCAL CODES. THERMOSTATIC MIXING VALVE PROVIDE THERMOSTATIC MIXING VALVE (TMV) AT EACH HAND SINK AND SET FOR 110°F. MIXING VALVE TO BE INSTALLED PER MANUFACTURER'S REQUIREMENTS WITH CHECK VALVES AT SUPPLY INLETS. SEE SPECIFICATIONS FOR REQUIREMENTS. PIPING SOIL, WASTE, AND VENT PIPING PIPE MATERIALS AS ALLOWED BY CODE. ALL HORIZONTAL RUNS SHALL DRAIN AT A GRADE OF 1/4" PER FOOT (21 MM PER METER) WHERE POSSIBLE BUT IN NO CASE LESS THAN 1/8" PER FOOT (10MM PER METER) WHERE ALLOWED & SIZED PER AHJ AND CODE. COORDINATE WITH LOCAL AUTHORITIES FOR DRAINAGE REQUIREMENTS FOR EQUIPMENT DESIGNATED WITH INDIRECT WASTE TO FLOOR SINKS. INDIRECT DRAIN LINES ARE TO MAINTAIN MIN. 1" (25MM) AIR GAP ABOVE FLOOR SINKS. PROVIDE PIPED DRAIN (P-TRAP AND VENT) TO SANITARY IF REQUIRED BY LOCAL JURISDICTION. CONDENSATE DRAINAGE PIPING THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS FOR STARBUCKS EQUIPMENT (REFER TO SCHEDULE). CONDENSATE DRAINAGE PIPING SHALL BE TYPE "M" COPPER TUBING WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH 50/50 SOLDER. HANGERS AND SUPPORTS THE PLUMBING CONTRACTOR SHALL FURNISH ALL PIPE SUPPORTS REQUIRED FOR EQUIPMENT AND MATERIAL IN ACCORDANCE WITH SPECIFICATIONS. ALL HORIZONTAL RUNS OF PIPING SHALL BE SUPPORTED BY PIPE HANGERS INSTALLED AS REQUIRED BY LOCAL CODES. ADDITIONAL SUPPORTS SHALL BE PROVIDED WHERE REQUIRED TO PREVENT SAGGING. - CONNECTIONS INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO EACH PIECE OF EQUIPMENT. INSTALL DIELECTRIC COUPLINGS TO CONNECT PIPING MATERIALS OF DISSIMILAR METALS. CLEANOUTS PROVIDE FLOOR AND WALL CLEANOUTS AS INDICATED ON THE DRAWINGS OR WHERE REQUIRED BY CODE IN ALL SOIL, WASTE, AND DRAIN LINES. CLEANOUTS SHALL BE SAME SIZE AS PIPE EXCEPT THAT CLEANOUTS LARGER THAN 4" WILL NOT BE REQUIRED. INSTALLATION INSTALL PIPING FREE OF SAGS AND BENDS. PROVIDE BRACKET STANDOFFS FROM MOUNTING SURFACES SUFFICIENT TO ALLOW 1" (25MM) OF CLEANING SPACE ALL AROUND PIPING, INCLUDING ANY ADDED PIPING INSULATION. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WALLS, GYPSUM BOARD PARTITIONS, CONCRETE FLOOR AND ROOF SLABS. SEAL PIPE PENETRATIONS THROUGH RATED CONSTRUCTION WITH FIRE STOPPING SEALANT MATERIAL PER CODE REQUIREMENTS. DO NOT INSTALL PEX PIPING IN RATED WALLS OR THROUGH RATED FLOORS. INSTALL PER MANUFACTURER'S INSTRUCTIONS AND ENSURE PROPER PROTECTION OF PEX PIPING FROM METAL EDGES. UNDERGROUND WATER AND SEWER LINES SHALL BE LAID IN SEPARATE TRENCHES WITH A MINIMUM HORIZONTAL SPACING AS REQUIRED BY CODE, EXCAVATED TO THE PROPER DEPTH AND GRADED TO PRODUCE THE REQUIRED FALL. TESTING TEL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE BACKFILLED OR CONCEALED. AFTER TESTING IS COMPLETE, THE PLUMBING CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS REQUIRED BY LOCAL AUTHORITY. TEST WATER PURITY ACCORDING TO LOCAL REQUIREMENTS AND SUBMIT CERTIFIED TEST RESULTS TO ENGINEER FOR REVIEW AND APPROVAL. IDENTIFICATION PROVIDE PIPE IDENTIFICATION EVERY 10 FT (EXCEPT WHERE PIPES ARE EXPOSED TO PUBLIC) IN ACCORDANCE WITH SPECIFICATIONS. INSULATION WATER PIPING UNLESS OTHERWISE REQUIRED BY THE LOCAL AUTHORITY OR ENERGY CODES, THE MINIMUM INSULATION LEVELS SHALL BE AS FOLLOWS: PIPE SIZE (DIAMETER) INSULATION THICKNESS LESS THAN 1 1/2" (38MM) = 1" (24MM) 1 1/2" (51 MM) OR GREATER = 1 1/2" (38MM) (INSULATION VALUE = K VALUE NOT EXCEEDING 0.27 BTU- INCH (WFT2*F) SAFETY COVERS FURNISH AND INSTALL SPECIFIED NO SCALD SAFETY COVERS WITH INSULATED FOAM LINER AND TAMPER PROOF STRAP AT ALL EXPOSED ADA SINK P-TRAPS AND WATER SUPPLIES AND AS REQUIRED BY JURISDICTION. SECTION 220517 - SLEEVES AND SLEEVE SEALS FOR PLUMBING PIPING 1.1 SLEEVE -SEAL SYSTEMS A. FIELD -ASSEMBLED, MODULAR SEALING -ELEMENT UNIT FOR FILLING ANNULAR SPACE BETWEEN PIPING AND SLEEVE.. 1. SEALING ELEMENTS: EPDM RUBBER. 2. PRESSURE PLATES: CARBON STEEL. 3. CONNECTING BOLTS AND NUTS: CARBON STEEL WITH CORROSION -RESISTANT COATING. 1.2 SLEEVE -SEAL FITTINGS A. MANUFACTURED PLASTIC, SLEEVE -TYPE, PLASTIC OR RUBBER WATERSTOP ASSEMBLY MADE FOR IMBEDDING IN CONCRETE SLAB OR WALL. 1.3 GROUT A. NONSHRINK, FACTORY PACKAGED. 1.4 SLEEVE AND SLEEVE -SEAL SCHEDULE A. EXTERIOR CONCRETE WALLS ABOVE GRADE: 1. PIPING SMALLER THAN NPS 6 (DN 150): CAST-IRON WALL SLEEVES. B. EXTERIOR CONCRETE WALLS BELOW GRADE: 1 PIPING SMALLER THAN NPS 6 (DN 150): CAST-IRON WALL SLEEVES WITH SLEEVE -SEAL SYSTEM. C. CONCRETE SLABS -ON -GRADE: 1. PIPING SMALLER THAN NPS 6 (DN 150): CAST-IRON WALL SLEEVES WITH SLEEVE -SEAL SYSTEM. D. INTERIOR PARTITIONS: 1. PIPING SMALLER THAN NPS 6 (DN 150): GALVANIZED -STEEL -PIPE SLEEVES. END OF SECTION 220517 SECTION 220523 - GENERAL DUTY VALVES FOR PLUMBING PIPING 1.1 DOMESTIC HOT- AND COLD -WATER VALVES A. PIPE NPS 2 (DN 50) AND SMALLER: 1. TWO-PIECE, BRASS BALL VALVES WITH FULL PORT, BRASS TRIM, AND LEAD FREE. 2. THREE-PIECE, BRASS BALL VALVES WITH FULL PORT, BRASS TRIM, AND LEAD FREE. 3. BRONZE SWING CHECK VALVES, CLASS 125 BRONZE DISC WITH THREADED END CONNECTIONS,AND LEAD FREE. , 4. BRONZE GATE VALVES, CLASS 125 NRS WITH THREADED ENDS, AND LEAD FREE. END OF SECTION 220523 SECTION 220719 - PLUMBING PIPING INSULATION 1.1 QUALITY ASSURANCE A. SURFACE -BURNING CHARACTERISTICS: FLAME -SPREAD INDEX OF 25, AND SMOKE -DEVELOPED INDEX OF 50 FOR INSULATION INSTALLED INDOORS ACCORDING TO ASTM E 84. 1.2 PIPING INSULATION SCHEDULE, GENERAL A. ITEMS NOT INSULATED: UNLESS OTHERWISE INDICATED, DO NOT INSTALL INSULATION ON THE FOLLOWING: 1. DRAINAGE PIPING LOCATED IN CRAWL SPACES. 2. BELOW -GRADE DRAINAGE PIPING. 3. CHROME -PLATED PIPES AND FITTINGS UNLESS THERE IS A POTENTIAL FOR PERSONNEL INJURY. 1.3 INDOOR PIPING INSULATION SCHEDULE A. DOMESTIC COLD WATER: FLEXIBLE ELASTOMERIC, MINERAL -FIBER, PREFORMED PIPEINSULATION, TYPE I OR PHENOLIC. B. DOMESTIC HOT AND RECIRCULATED HOT WATER: FLEXIBLE ELASTOMERIC, MINERAL -FIBER, PREFORMED PIPE INSULATION, TYPE I OR PHENOLIC. C. STORMWATER AND OVERFLOW: 1/2" MINIMUM, CELLULAR GLASS, FLEXIBLE ELASTOMERIC, MINERAL -FIBER, PREFORMED PIPE INSULATION, TYPE I, PHENOLIC OR POLYOLEFIN. D. ROOF DRAIN AND OVERFLOW DRAIN BODIES: 1/2" MINIMUM, CELLULAR GLASS, FLEXIBLE ELASTOMERIC, MINERAL -FIBER, PREFORMED PIPE INSULATION, TYPE I, PHENOLIC OR POLYOLEFIN. E. HOT SERVICE DRAINS: CELLULAR GLASS OR MINERAL -FIBER, PREFORMED PIPE, TYPE I OR II. F. ICE BIN DRAIN: INSULATE DRAIN LINES WITH 1/2" (13MM) THICK SELF-SEALING, SECTIONAL, CLOSED CELL FOAM. G. DOMESTIC COLD AND HOT WATER IN CASEWORK AND BAR AREAS: FLEXIBLE ELASTOMERIC, MINERAL -FIBER, PREFORMED PIPE INSULATION, TYPE I OR PHENOLIC. 1.4 OUTDOOR, ABOVEGROUND PIPING INSULATION SCHEDULE A. DOMESTIC WATER PIPING: FLEXIBLE ELASTOMERIC, MINERAL -FIBER, PREFORMED PIPE INSULATION, TYPE I OR PHENOLIC. 1.5 INDOOR, FIELD -APPLIED JACKET SCHEDULE A. PIPING, CONCEALED: ALUMINUM. PIPING, EXPOSED: ALUMINUM. END OF SECTION 220719 SECTION 221116 - DOMESTIC WATER PIPING 1.1 INFORMATIONAL SUBMITTALS A. SYSTEM PURGING AND DISINFECTING ACTIVITIES REPORT. B. FIELD QUALITY -CONTROL REPORTS. 1.2 FIELD CONDITIONS A. INTERRUPTION OF EXISTING WATER SERVICE: DO NOT INTERRUPT WATER SERVICE TO FACILITIES OCCUPIED BY OWNER OR OTHERS UNLESS PERMITTED UNDER THE FOLLOWING CONDITIONS AND THEN ONLY AFTER ARRANGING TO PROVIDE TEMPORARY WATER SERVICE ACCORDING TO REQUIREMENTS INDICATED: 1. NOTIFY CONSTRUCTION MANAGER NO FEWER THAN TWO DAYS IN ADVANCE OF PROPOSED INTERRUPTION OF WATER SERVICE. 2. DO NOT INTERRUPT WATER SERVICE WITHOUT CONSTRUCTION MANAGER'S WRITTEN PERMISSION. 1.3 PIPING MATERIALS A. POTABLE -WATER PIPING AND COMPONENTS SHALL COMPLY WITH NSF 14 AND NSF 61 ANNEX G. PLASTIC PIPING COMPONENTS SHALL BE MARKED WITH "NSF-PW". 1.4 UNDER -BUILDING -SLAB, DOMESTIC WATER, BUILDING SERVICE PIPING A. PIPE NPS 3 (DN 80) AND SMALLER: 1. SOFT COPPER TUBE; WROUGHT -COPPER; AND BRAZED JOINTS. 2. OTHER APPROVED PIPING WHEN SOIL IS CORROSIVE. 1.5 UNDER -BUILDING -SLAB, DOMESTIC WATER PIPING A. PIPE NPS 2 (DN 50) AND SMALLER: 1. HARD COPPER TUBE; WROUGHT -COPPER; AND BRAZED JOINTS. 2. OTHER APPROVED PIPING WHEN SOIL IS CORROSIVE. 3. 1.6 ABOVE GROUND DOMESTIC WATER PIPING A. PIPE NPS 2 (DN 50) AND SMALLER: 1. HARD COPPER TUBE; WROUGHT -COPPER; SOLDER -JOINT FITTINGS; AND SOLDERED JOINTS WITH NON -LEAD, NON -ANTIMONY SOLDER. END OF SECTION 221116 SECTION 221119 - DOMESTIC WATER PIPING SPECIALTIES 1.1 QUALITY ASSURANCE A. QUALITY STANDARDS: NSF 14 AND NSF 61. 1.2 PRODUCTS A. VACUUM BREAKERS: 1. PIPE -APPLIED, ATMOSPHERIC -TYPE VACUUM BREAKERS: ROUGH -BRONZE FINISH. 2. AIR -GAP FITTING: ASME Al12.1.2, MATCHING BACKFLOW-PREVENTER CONNECTION. 3. HOSE -CONNECTION VACUUM BREAKERS: CHROME- OR NICKEL -PLATED FINISH. 4. PRESSURE VACUUM BREAKERS. B. BACKFLOW PREVENTERS: 1. REDUCED -PRESSURE -PRINCIPLE BACKFLOW PREVENTERS: a. BODY: BRONZE FOR NPS 2 (DN 50) AND SMALLER. b. END CONNECTIONS: THREADED FOR NPS 2 (DN 50) AND SMALLER. c. CONFIGURATION: HORIZONTAL, STRAIGHT THROUGH. d. LEAD FREE. 2. DOUBLE-CHECK BACKFLOW-PREVENTION ASSEMBLIES: a. BODY: BRONZE FOR NPS 2 (DN 50) AND SMALLER. b. END CONNECTIONS: THREADED FOR NPS 2 (DN 50) AND SMALLER. C. CONFIGURATION: HORIZONTAL, STRAIGHT THROUGH. d. LEAD FREE. 3. HOSE -CONNECTION BACKFLOW PREVENTERS. C. WATER PRESSURE -REDUCING VALVES: 1. WATER REGULATORS: a. BODY: BRONZE FOR NPS 2 (DN 50) AND SMALLER. b. VALVES FOR BOOSTER HEATER WATER SUPPLY: INCLUDE INTEGRAL BYPASS. C. END CONNECTIONS: THREADED FOR NPS 2 (DN 50) AND SMALLER D. TEMPERATURE -ACTUATED WATER MIXING VALVES: 1. WATER -TEMPERATURE LIMITING DEVICES: a. CONNECTIONS: THREADED UNION INLETS AND OUTLET. b. FINISH: CHROME PLATED. 2. PRIMARY, THERMOSTATIC, WATER MIXING VALVES: a. TYPE: CABINET MOUNTED. b. CONNECTIONS: THREADED UNION INLETS AND OUTLET. C. FINISH: ROUGH BRONZE. d. PIPING: COPPER. e. CABINET: SURFACE MOUNTED. E. STRAINERS FOR DOMESTIC WATER PIPING: 1. BODY: BRONZE FOR NPS 2 (DN 50) AND SMALLER; CAST IRON WITH INTERIOR LINING AND EPDXY COATING FOR NPS 2-1/2 (DN 65) AND LARGER. 2. CONNECTIONS: THREADED FOR NPS 2 (DN 50) AND SMALLER; FLANGED FOR NPS 2-1/2 (DN 65) AND LARGER. 3. SCREEN: STAINLESS STEEL WITH ROUND PERFORATIONS UNLESS OTHERWISE INDICATED. 4. DRAIN: PIPE PLUG. F. OUTLET BOXES: 1. ICEMAKER OUTLET BOXES: ENAMELED -STEEL OR EPDXY -PAINTED -STEEL BOX AND FACEPLATE. G. HOSE BIBBS: 1.. VACUUM BREAKER: INTEGRAL OR FIELD INSTALLATION. 2.. FINISH FOR SERVICE AREAS: CHROME OR NICKEL PLATED. 3.. OPERATION FOR SERVICE AREAS: OPERATING KEY. 4. OPERATION FOR FINISHED ROOMS: OPERATING KEY. 5. WALL FLANGE WITH EACH CHROME- OR NICKEL -PLATED HOSE BIBB. H. WALL HYDRANTS: 1. NONFREEZE WALL HYDRANTS: a. OUTLET: CONCEALED. b. FINISH: CHROME PLATED. 2. NONFREEZE, HOT- AND COLD -WATER WALL HYDRANTS: a. OUTLET: CONCEALED. b. FINISH: CHROME PLATED. 3. MODERATE -CLIMATE WALL HYDRANTS: a. OUTLET: CONCEALED. b. FINISH: CHROME PLATED. 4. VACUUM BREAKER WALL HYDRANTS: LOOSE KEY. I. POST HYDRANTS: 1. NONFREEZE, DRAINING -TYPE POST HYDRANTS. 2. NONFREEZE, NONDRAINING-TYPE POST HYDRANTS. 3. FREEZE -RESISTANT SANITARY YARD HYDRANTS: ZINC -PLATED STEEL CANISTER. J. DRAIN VALVES: BALL -VALVE TYPE. K. WATER HAMMER ARRESTERS: METAL BELLOWS. L. AIR VENTS: BOLTED CONSTRUCTION. M. TRAP -SEAL PRIMER VALVES: SUPPLY TYPE. 1.3 MANUFACTURED UNITS A. TRAP -SEAL PRIMER SYSTEMS: 1. CABINET: RECESSED- MOUNTED STEEL BOX WITH STAINLESS -STEEL COVER. 2. NUMBER OUTLETS: FOUR. 1.4 DOMESTIC WATER PIPE FITTINGS AND APPURTENANCES ARE LEAD FREE. END OF SECTION 221119 SECTION 221316 - SANITARY WASTE AND VENT PIPING 1.1 PROJECT CONDITIONS A. INTERRUPTION OF EXISTING SANITARY WASTE SERVICE: DO NOT INTERRUPT SERVICE TO FACILITIES OCCUPIED BY OWNER OR OTHERS UNLESS PERMITTED UNDER THE FOLLOWING CONDITIONS AND THEN ONLY AFTER ARRANGING TO PROVIDE TEMPORARY SERVICE ACCORDING TO REQUIREMENTS INDICATED: 1. NOTIFY CONSTRUCTION MANAGER NO FEWER THAN TWO DAYS IN ADVANCE OF PROPOSED INTERRUPTION OF SANITARY WASTE SERVICE. 2. DO NOT PROCEED WITH INTERRUPTION OF SANITARY WASTE SERVICE WITHOUT CONSTRUCTION MANAGER'S WRITTEN PERMISSION. 1.2 MATERIALS A. HUB -AND -SPIGOT, SERVICE- CLASS, CAST-IRON SOIL PIPE AND FITTINGS BELOW GRADE WHERE REQUIRED BY LOCAL CODE. B. HUBLESS, CAST-IRON SOIL PIPE AND CISPI HUBLESS PIPING COUPLINGS. C. SOLID -WALL SCHEDULE 40 ABS PIPE WITH ABS SOCKET FITTINGS MAY BE USED ABOVE AND BELOW GRADE IF ALLOWED BY LOCAL CODE. D. SHIELDED, NONPRESSURE TRANSITION COUPLINGS. E. UNION DI -ELECTRIC FITTINGS. F. PE -FILM ENCASEMENT FOR UNDERGROUND METAL PIPING. G. SCHEDULE 40 PVC PIPE WITH PVC SOCKET FITTING MAY BE USED BELOW GRADE IF ALLOWED BY LOCAL AUTHORITY. 1.3 ADHESIVES A. ADHESIVES SHALL NOT EXCEED A VOC CONTENT OF 51 OG/L FOR PVC AND 325 G/L FOR ABS. END OF SECTION 221316 SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES 1.1 ACTION SUBMITTALS PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. INCLUDE RATED CAPACITIES, OPERATING CHARACTERISTICS, AND ACCESSORIES FOR THE FOLLOWING: 1. GREASE INTERCEPTORS. 1.2 QUALITY ASSURANCE A. QUALITY STANDARD FOR BELOW GRADE PLASTIC PIPING: NSF 14. 1.3 PRODUCTS A. CLEANOUTS: 1. EXPOSED: COUNTERSUNK BRASS CLOSURE PLUG. 2. CERAMIC TILE AND CARPETED FLOORS: SQUARE, ADJUSTABLE WITH NICKEL 2. BRONZE TOP. 3. RESILIENT (VINYL) FLOOR: SQUARE, ADJUSTABLE, NICKEL BRONZE TOP WITH 3. COMPATIBLE FLANGE. 4. WALL: ROUND, FLAT, CHROME -PLATED BRASS OR STAINLESS -STEEL COVER PLATE WITH ROUND, CHROME PLATED, SCREW WALL ACCESS. B. FLOOR DRAINS: 1. CAST-IRON FLOOR DRAINS, WITH STRAINER, BODY STYLE AND OPTIONS AS SPECIFIED IN PLUMBING SCHEDULE. 2. PROVIDE TRAP PRIMER CONNECTIONS WHERE NEEDED. C. THROUGH -PENETRATION FIRESTOP ASSEMBLIES: LISTED AND LABELED ASSEMBLY OF SLEEVE AND STACK FITTING WITH FIRESTOPPING PLUG. D. MISCELLANEOUS SANITARY DRAINAGE PIPING SPECIALTIES: 1. OPEN DRAINS, SHOP OR FIELD FABRICATE FROM SERVICE CLASS, HUB -AND -SPIGOT, 2. CAST-IRON, SOIL -PIPE FITTINGS. CAST-IRON OR BRONZE DEEP -SEAL TRAPS. 3. FLOOR -DRAIN, TRAP -SEAL PRIMER FITTINGS. 4. AIR -GAP FITTINGS. 5. COUNTERFLASHING-TYPE, CAST-IRON STACK FLASHING FITTINGS. 6. CAST-IRON BODY VENT CAPS. 7. FROST -RESISTANT VENT TERMINALS. RECEIVE8. EXPANSION JOINTS. 9. AIR ADMITTANCE VALVES. ,Jul 28 2020 1.4 MANUFACTURED UNITS CITY OFEDMONDS A. GREASE INTERCEPTORS AS SPECIFIED IN PLUMBING SCHEDULE. DEVELOPMENT SERVICES DEPARTMENT END OF SECTION 221319 GRAPHITE Graphite Design Group, LLC 1809 7th Avenue, Suite #700 Seattle, WA 98101 206,224.3335 www.graphitedesigngroup.com OWNER SAFEWM Safeway, Inc. 1371 Orchard Blvd. #200 Walnut Creek, CA 94596 425.201,6411 CONSULTANT H A R G I S mechanical 1201 third avenue, suite 600 telecommunications electrical ons seattle, washington 98101 security energy t 206.448.3376 w hargis.biz SEAL Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED / REVISED DATE PERMIT SET 07/15/2020 12020 PLUMBING NOTES AND SPECIFICATIONS P-000 1 L_ 1 2 3 4 S 6 m DESIGN ARCHITECT a 0 c 0 15 3"W UP 1-1/2"V UP A FIXTURES DRAINING TO GREASE INTERCEPTOR COMPARTMENT SIZE (LxWxH) COMPARTMENTS *GALLONS # OF FIXTURES TOTAL GALLONS 3-COMP SINK 13.625 20.25 14 3 38 1 38 SINK (HAND SINK) 10 14 10 1 5 1 5 MAX. DRAINAGE LOAD (GAL) *FIXTURE GALLONS BASED ON 75% COMPARTMENT FILL 43 2 MIN DRAIN DOWN FLOW RATE (GPM) 21.5 SCHIER GB-3 RATED FLOW CAPACITY (GPM) 50 SCHIER GB-3 IS RATED FOR 50 GPM AND 272.7 POUNDS OF GREASE RETENTION. REQUIRED GREASE RETENTION CAP (LBS) 43 PLUMBING ABOVE FLOOR PLAN Scale: 1/4" = 1'-0" 1-1/2"V UP 15 3"W UP — 0 O I I 3"W � 1 2"W UP 12 2"W PLUMBING BELOW FLOOR PLAN Scale: 1/4" = 1'-0" P 13076 P 12501 P 13077 P 13081 P 13078 P 13079 P 13149 P 13087 0 2' 4' Scale: 1/4" = 1'-0" 0 2' 4' Scale: 1/4" = 1'-0" (3) P 19494 5 14 N 8' 1 PLUMBING PLAN GENERAL NOTES A. PROVIDE A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. ALL PLUMBING SHALL BE DONE IN ACCORDANCE WITH LOCAL CODES. B. PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. C. ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS. D. REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS OTHERWISE NOTED. E. COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. G. DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. H. INSULATE ICE BIN DRAINAGE PIPES. I. ALL PLUMBING LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2" (10MM) THICK SELF SEALING, SECTIONAL CLOSED -CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. J. CONTRACTOR SHALL CONTACT WATER FILTRATION SUPPLIER TO COORDINATE SCOPE OF WORK AND SCHEDULE PRIOR TO INSTALLATION OF WATER FILTRATION SYSTEM. K. PROVIDE WALL CLEANOUTS AT ALL SINKS AND AS NEEDED PER CODE (NOT ALL SHOWN). L. WHEN BUNDLING SEVERAL INDIRECT WASTE LINES TO DRAIN INTO A FLOOR SINK, A UNISTRUT IS REQUIRED FOR SECURING AND BRACING ALL LINES ABOVE THE DRAIN. M. FURNISH & INSTALL ALL NEEDED INDIRECT DRAINS PER CODE (NOT ALL SHOWN). INSTALL DRAINS AT 2% SLOPE WHERE POSSIBLE WITHOUT DIPS OR SAGS. ALL INDIRECT DRAINS SHALL RUN SEPARATELY FROM EACH OTHER TO INDIRECT DRAIN RECEPTOR AND SHALL TERMINATE WITH AN AIR GAP PER CODE. SHEET NOTES 1. ROUTE DRAIN LINE AS REQUIRED BY AHJ, FROM DRIP TRAY TO NEAREST FLOOR SINK. TERMINATE WITH PROPER AIR GAP. 2. WATER FILTER: ROUTE 3/4" COLD WATER IN WALL AND CONNECT TO WATER FILTER, EXTEND 3/4" FILTERED COLD WATER FROM WATER FILTER TO EQUIPMENT. PLUMBING CONTRACTOR TO FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ACTIVATION PROCEDURES FOR FILTERS. INSTALL ASSEMBLY ON WALL, REFER TO WATER FILTER DETAIL. 3. 3-COMPARTMENT SINK: ROUTE 1/2" HOT AND COLD WATER IN WALL AND CONNECT TO FAUCET AND OVERHEAD SPRAY. CAULK AND SEAL BACK OF SINK TO WALL. ROUTE WASTE PIPING FROM SINK TO FLOOR SINK THROUGH MINIMUM 2" AIR GAP. 4. EXTEND AND CONNECT 3" SANITARY WASTE PIPING INTO EXISTING BELOW GRADE SANITARY WASTE PIPING OF EQUAL OR LARGER SIZE. FIELD VERIFY EXACT LOCATION, SIZE, DEPTH OF INVERT, AND DIRECTION OF FLOW PRIOR TO START OF ANY WORK. 5. ICE MACHINE: ROUTE 1/2" FILTERED COLD WATER IN WALL AND CONNECT TO ICE MACHINE, PROVIDE WITH REQUIRED BACKFLOW PREVENTION DEVICE. REDUCE WATER LINE TO 3/8" AT UNIT. ROUTE (2) 3/4" INSULATED INDIRECT DRAINS TO FLOOR SINK. DO NOT INTERCONNECT DRAINS. 6. HAND SINK: ROUTE 1/2" HOT AND COLD WATER IN WALL AND CONNECT TO HAND SINK/LAVATORY. CONTRACTOR TO PROVIDE THERMOSTATIC MIXING VALVE BELOW FIXTURE AND SET TO 110°F. MIXING VALVE SHALL BE ASSE 1070 COMPLIANT. REPLACE AERATOR PROVIDED WITH FAUCET WITH 0.5 GPM VANDAL RESISTANT FLOW CONTROL AERATOR. ROUTE 2" SANITARY WASTE PIPING BELOW SLAB AND EXTEND UP IN WALL WITH WALL CLEAN -OUT, THEN TRANSITION TO 1-1/2" SANITARY WASTE PIPING AND CONNECT TO SINK. 7. COFFEE BREWER: ROUTE 1/2" FILTERED COLD WATER IN WALL. CONTRACTOR SHALL PROVIDE SHUT-OFF VALVE IN CABINET AT 24" AFF. REDUCE WATER LINE TO 3/8" AT UNIT. 8. ESPRESSO MACHINE: ROUTE 1/2" FILTERED COLD WATER IN CASEWORK AND CONNECT TO ESPRESSO MACHINE. PROVIDE BRAIDED STAINLESS STEEL HOSE FROM SHUT-OFF VALVE TO PUMP AND FROM PUMP TO ESPRESSO MACHINE'S WATER INLET. ROUTE 1-1/2" INDIRECT WASTE PIPING IN CASEWORK TO FLOOR SINK, FIELD VERIFY EXACT LOCATION. PLUMBING FIXTURE SCHEDULE - "Prr DESIGN ID COUNT DESCRIPTION RESP. COMMENTS FAUCET 11003 1 1 IFAUCET - DIPPERWELL 3PV-GC INEW METERED VERSION FILTER 12501 1 FILTER - RO SYSTEM 6000PD 3PV-3PV 3PV AND GC TO COORDINATE FINAL WATER SYSTEMS SPECIFICATIONS 13076 1 FILTER - PREFILTRATION SYSTEM 3PV-3PV 3PV AND GC TO COORDINATE FINAL WATER SYSTEMS SPECIFICATIONS 13077 1 FILTER - HEAD SINGLE 3PV-3PV 3PV AND GC TO COORDINATE FINAL WATER SYSTEMS SPECIFICATIONS 13078 1 FILTER - CARBON FILTER CARTRIDGE WITH SCALE REDUCTION 3PV-3PV 3PV AND GC TO COORDINATE FINAL WATER SYSTEMS SPECIFICATIONS 13079 1 FILTER - HEAD TRIPLE 3PV-3PV 3PV AND GC TO COORDINATE FINAL WATER SYSTEMS SPECIFICATIONS 13081 3 FILTER - CARBON FILTER CARTRIDGE 3PV-3PV 3PV AND GC TO COORDINATE FINAL WATER SYSTEMS SPECIFICATIONS 13087 1 FILTER - WATER CONDITIONING CABINET 3PV-3PV 3PV AND GC TO COORDINATE FINAL WATER SYSTEMS SPECIFICATIONS 13149 1 FILTER - PRESSURE GAUGE 3PV-3PV 3PV AND GC TO COORDINATE FINAL WATER SYSTEMS SPECIFICATIONS DRAIN 10726 2 FLOOR SINK - GRATE HALF SQUARE - 121N 305MM ZURN FD2375-NH2-H A.R.E., 6" SUMP WITH 1/2 GRATE ICE 19494 1 1 ICE MACHINE 3PV-GC OTHER GI 1 GREASE INTERCEPTOR - SCHIER GB-3 GC/GC 50GPM, 272.7 LBS. GREASE CAPACITY PROVIDE VENT PER LOCAL AHJ WATER BY-PAS1c NOTE: PROVIDE THREADED FITT AND UNIONS TO ALLOW EASY REMOVAL OF Ufa AND VALVES (Tl BY-PASS VALVE WATER IN CONDITIONED WATER OUT HUT -OFF ALVE (TYP) LTER UNIT CONDITIONED WATER OUT BY-PASS PIPING DIAGRAM scale: NONE 9. DIPPER WELL: EXTEND 1/2" COLD WATER UP IN CASEWORK AND CONNECT TO DIPPER WELL. ROUTE 1/2" INDIRECT WASTE PIPING IN CASEWORK TO FLOOR SINK. 10. EXISTING SANITARY WASTE PIPING BELOW SLAB. FIELD VERIFY SIZE, INVERT, LOCATION AND DIRECTION OF FLOW. 11. FLOOR SINK: PROVIDE 3" SANITARY WASTE AND 1-1/2" VENT. 12. HAND SINK: PROVIDE 2" SANITARY WASTE AND 1-1/2" VENT. 13. FLOOR CLEANOUT: MATCH SIZE OF THE DRAIN LINE. CLEANOUT SHALL BE INSTALLED FLUSH WITH FINISHED FLOOR. 14. ICE BIN: ROUTE 1-1/2" INDIRECT WASTE PIPING FROM ICE BIN IN CASEWORK TO FLOOR SINK. 15. FLOOR SINK: ROUTE 3" SANITARY WASTE UP AND CONNECT TO FLOOR SINK, EXTEND 1-1/2" VENT UP. 16. GREASE TRAP: PROVIDE GREASE TRAP (SCHIER GB-3) COMPLETE WITH EXTENSION RISERS (SAMPLE PORT AND VENTING IF REQUIRED BY THE AHJ). PEDESTRIAN RATED LID COVER SHALL BE FLUSH WITH FINISHED FLOOR. SEE GREASE TRAP DETAIL 4/P-1101. 17. SUPPLY PIPES: ROUTE PIPING IN WALL AND/OR BELOW COUNTER. NOT ALL PIPES ARE SHOWN FOR CLARITY. 18. INTERCEPT AND CONNECT TO (E) UNDER FLOOR HOT AND COLD WATER SUPPLY. PROVIDE SHUT-OFF VALVE IN NEW PIPE AT POINT OF CONNECTION. FIELD VERIFY EXACT SIZE AND LOCATION. ROUTE UP THROUGH FLOOR UNDER COUNTER SPACE. 19. PROVIDE AIR ADMITTANCE VALVE AND INSTALL PER MFR. RECOMMENDATIONS AND WITH REQUIRED ACCESS. 20. WATER FILTER: 3/8" FILTERED CW TO PRE -FILTER, THEN ON TO FINAL FILTERS. PIPE BOTH UNITS WITH A BYPASS FOR FILTER CHANGE OUT. SEE DETAIL 3/P-1101. REDUCE PIPING AT UNITS. PLUMBING MATERIAL SCHEDULE PIPING TYPE MATERIAL REMARKS DRAIN & WASTE -BELOW SOLID WALL SCH. 40 PVC DWV FITTINGS: SOLVENT WELD GRADE PIPE OR SOLID WALL SCH. 40 ABS DRAIN & WASTE - BELOW FITTINGS: STANDARD WEIGHT CAST IRON NO -HUB WITH GRADE CAST IRON STANDARD -DUTY COUPLINGS STANDARD WEIGHT CAST IRON - FITTINGS: STANDARD WEIGHT CAST IRON NO -HUB WITH DRAIN &WASTE -ABOVE GRADE, NO -HUB OR DWV COPPER OR STANDARD -DUTY COUPLINGS OR SOLDERED WROUGHT 4" AND SMALLER SOLID WALL SCH. 40 ABS COPPER DWV (2-1/2" OR LESS) OR ABS SOCKET FITTINGS. (WHERE ALLOWED BY AHJ) STANDARD WEIGHT CAST IRON - FITTINGS: STANDARD WEIGHT CAST IRON NO -HUB WITH VENT NO -HUB OR DWV COPPER OR STANDARD -DUTY COUPLINGS OR SOLDERED WROUGHT SOLID WALL SCH. 40 ABS COPPER DWV (2-1/2" OR LESS) OR ABS SOCKET FITTINGS. (WHERE ALLOWED BY AHJ) DOMESTIC WATER PIPING TYPE L COPPER TUBING FITTINGS: WROUGHT -COPPER WITH 95/5 SOLDER OR PROPRESS/ NIBCO PRESS MECHANICAL JOINT FITTINGS. VENT, IF REQ'D BY AHJ :e37W_- T. �Inncu�n CI nno BEDDING VENT, IF REQ'D BY AHJ non�imn nvTnnicl�nl I SAMPLE PORT (SV24-L4), IF REQUIRED BY AHJ JPtINI 1 r%r\ 1 vv/—%J I L NOTE: UNIT SHALL BE CERTIFIED TO ASME Al 12.14.3 (TYPE C) AND CSA B481.1 INSTALL PER MANUFACTURER'S RECOMMENDATIONS. GREASE TRAP DETAIL scale: NONE GRAPHITE Graphite Design Group, LLC 1809 lth Avenue, Suite #700 Seattle, WA 98101 206,224,3335 www.graphitedesigngroup.com OWNER 'qfth. �Z! SAFEVW r Safeway, Inc. 1371 Orchard Blvd, #200 Walnut Creek, CA 94596 425.201.6411 CONSULTANT H A R G I S mechanical 1201 third avenue, suite 600 electrical telecommunications seattle, washington 98101 security energy t 206.448.3376 w hargis.biz I SEAL M RECEIVED Jul 28 2020 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Starbucks Remodel Safeway Store #1297 23632 HWY 99 EDMONDS, WA 98026 ISSUED / REVISED DATE PERMIT SET 07/15/2020 +» r 20657 OVAL PLUMBING DESIGN PLAN P-1101