APPROVED BLD-BLD2022-0873+Architectural_Plan+7.5.2022_8.55.38_AM+2969061GENERAL NOTES ENERGY CODE DRAWING INDEX GENERAL REQUIREMENTS 1. CODES ARCHITECTURE: 2018 EDITION OF THE INTERNATIONAL RESIDENTIAL CODE, STRUCTURAL 2018 EDITION OF THE INTERNATIONAL BUILDING CODE, 2018 WASHINGTON ENERGY CODE, EDMONDS MUNICIPAL CODE 2. ALL WORK TO BE IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK. 3. CONTRACTOR TO VERIFY ALL DIMENSIONS, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK. ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. 7. DO NOT SCALE DRAWINGS. VERIFY DISCREPANCIES WITH ARCHITECT. 8. CONTRACTOR TO COORDINATE ALL OPERATIONS: INCLUDING SITE ACCESS/BARRICADES, MATERIAL STORAGE, STAGING, TEMPORARY AND UTILITIES 9. CONTRACTOR TO OBTAIN ANY OTHER PERMITS AS REQUIRED TO COMPLETE THE PROJECT. 10. DETAILS SHOWN ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED. DETAILS OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF THE SAME NATURE AS THOSE DRAWN FOR SIMILAR CONDITIONS. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WEATHER PROOFING TO CONSTRUCT A WATERPROOF TIGHT STRUCTURE. ALL WATERPROOFING SUCH AS FLASHING SIDING AND ROOFING SHALL BE CONSTRUCTED PER MANUFACTURERS INSTRUCTIONS AND BY INDUSTRY STANDARDS 12. ANY DISCREPANCY WITH STRUCTURAL DRAWINGS, THEN STRUCTURAL SHALL SUPERSEDE. SOILS & SITE WORK 1. ALL CUTS TO BE 1:1 OR PER GEOTECH REPORT IF PROVIDED. 2. BACKFILL AT FOUNDATIONS SHALL BE COURSE GRANULAR FILL WITH WATERPROOFING AT BASEMENT FOUNDATION WITH PERFORATED FOOTING DRAIN TO APPROVED DRAINAGE SYSTEM 3. GRADE AT PERIMETER OF BUILDING SHALL SLOPE AWAY FROM STRUCTURE AT A MINIMUM OF 4" PER FOOT SLOPE. FIRE CODE REQUIREMENTS & FIRESTOPPING 1. SMOKE ALARMS SHALL BE LOCATION IN EACH BEDROOM, OUTSIDE EACH BEDROOM AND AT EACH FLOOR. 2. SMOKE ALARMS TO BE HARD WIRED WITH BATTERY BACK UP 3. CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH BEDROOM IN UNITS WITH GAS APPLIANCES AND WHERE THERE ARE ATTACHED GARAGES. 4. R302.11 FIRESTOPPING SHALL STOP ALL CONCEALED DRAFT OPENINGS AT STUDS, PARTITIONS, STAIRS, SOFFIT SPACE AND PIPE/ VENTS LOCATIONS. THE SPACE IS NOT TO EXCEED 10'. 5. GARAGE: BETWEEN GARAGE CEILING AND HABITABLE SPACE SHALL HAVE 5/8" TYPE "X" GWB, BETWEEN GARAGE AND HABITABLE SPACE OR ATTIC SHALL BE 1/2" TYPE "X" GWB. GARAGE GWB SHALL HAVE FIRE TAPED JOINTS WITH SET NAILS AND COMPOUND. 6. AT ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE 1/2" TYPE "X" GWB. MISCELLANEOUS REQUIREMENTS 1. ALL EXPOSED WOOD TO BE 6" FROM SOIL 2. WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED OR SEPARATED FORM CONCRETE. 3. SAFETY GLAZING SHALL BE INSTALLED IN ALL WINDOWS WITHIN 24" OF DOOR, WITHIN DOORS, WITHIN 5' TO STAIRS BELOW 5' AND BELOW 5' OF TUB/ SHOWER. 4. ALL BEDROOMS SHALL OF AN EGRESS WINDOW OR DOOR. MINIM OF 5.7 SF WITH 24" CLEAR HEIGHT AND 20" CLEAR WIDTH. 5. GUARD RAILS SHALL BE 36" ABOVE FINISHED FLOOR WITH MAX OF 4" BETWEEN OPENING. STRUCTURAL CONNECTIONS PER STRUCTURAL PLANS. 6. STAIRS SHALL BE MINIMUM OF 36" WIDE, MAX RISER OF 7.75" AND MIN TREAD OF 10". 7. HANDRAILS AT STAIRS TO BE 34" TO 38" ABOVE NOSING, MINIMUM 1 2" CLEAR FROM WALL AND TERMINATE AT WALL OR NEWEL POST. 8. UNVENTED ROOF ALLOWED PER R806.5 5.1.1 AIR IMPERMEABLE INSULATION IN DIRECT CONTACT WITH UNDERSIDE OF STRUCTURAL ROOF SHEATHING 51.3 AIR IMPERMEABLE MIN R-10 INSULATION IN DIRECT CONTACT WITH ROOF SHEATHING, AIR PERMEABLE INSULATION SHALL BE INSTALLED DIRECTLY UNDER AIR IMPERMEABLE INSULATION INSULATION AND FENESTRATION REQUIREMENTS TABLE R402.11 FOR CLIMATE ZONE 5 AND MARINE 4 FENESTRATION U=0.30 SKYLIGHTS U=0.50 CEILING R49 VAULTED CLG., SINGLE RAFTER R38 WOOD FRAME WALL R21 int FLOOR R30 SLAB R-10 R406, TABLE 406.2 AND 406.3 ENERGY SYSTEM AND ENERGY CREDITS SECTION R406, TABLE 406.2 ENERGY CREDITS ADDITIONS UNDER 500 SF = 1.5 CREDITS REQUIRED (THIS PROJECT 32 SF OF NEW HEATED SPACE IN EXITING STORAGE AREA) SYSTEM TYPE 2 = 1 CREDIT HEAT PUMP THAT MEETS FEDERAL STANDARD FOR THE EQUIPMENT LISTED IN TABEL C403.3.2(4) OR C403.3.2(5) PROPOSED NEW HEAT PUMP FOR THE ENTIRE HOUR OPTION 3.4 HIGH EFFICIENCY HVAC: 1.5 CREDITS DUCTLESS MINI -SPLIT HEAT PUMP SYSTEM MIN. HSPF 10.0 FOR LARGEST ZONE OF HOUSE, AND ZONAL ELECTIC TOTAL 2.5 CREDITS PROVIDED MISCELLANEOUS ENERGY NOTES SECTION R503.1.1 ALTERATIONS, BUILDING ENVELOPE, SHALL COMPLY WITH ENERGY CODE R402 EXCEPTION, EXISTING CEILING, WALL OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION PROVIDED THESE CAVITIES ARE FILLED WITH INSULATION. 2X4 FRAMED WALLS WITH R-15 AND 2X6 WALLS WITH R-21 R402.4.4 RECESSED LIGHTING INSTALLED IN BUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR LEAKAGE, ALL RECESSED LIGHTING SHALL BE TYPE 1C-RATED AND LABELED CERTIFIED UNDER ASTM E283, RECESSED LUMINARIES SHALL BE SEALED WITH GASKET OR CAULK. R403.5.3 HOT WATER PIPES TO BE INSULATED MIN R-3 M1507.4.2.1 LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED MANUALLY KITCHEN - 100 CFM INTERMITTENT BATHROOM - 50 CFM INTERMITTENT R404.1 LIGHTING EQUIPMENT- MINIMUM OF 90% OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH EFFICIENCY LAMPS R101.4.3.1 -IF THERE WILL BE ALTERATIONS TO THE EXISTING FURNACE THAN PROVIDE A COPY OF THE "DUCT LEAKAGE TEST RESULTS FOR EXISTING BUILDINGS" TO THE BUILDING INSPECTOR AND HOMEOWNER PRIOR TO AN APPROVED FINAL INSPECTION R303.10 & R403.1 PROVIDE PROGRAMMABLE THERMOSTAT FOR THE PRIMARY SPACE CONDITIONING SYSTEM WITH THE AADU, SEPARATION OF THE AADU CONTROLS FROM THE PRIMARY DWELLING R402.4.1.2 EXCEPTION. - AIR LEAKAGE TEST NOT REQUIRED FOR ADDITIONS UNDER 500 SF EQUIPMENT SIZING FORM NOT REQUIRED FOR ADDITION UNDER 500 SF IWHERE ADDITIONS OR ALTERATIONS REQUIRE A cn PERMIT TO BE ISSUED INTERCONNECTED SMOKE w ' I � ALARM AND CO DETECTORS THROUGHOUT THE I I J DWELLING IS REQUIRED. REFER TO 2018 IRC R314 I AND 315 FOR MORE INFORMATION I = APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES r- - - - - - - - - - - - - - - - - - - I SEPARATE PLUMBING PERMIT REQUIRED FOR THIS PROJECT. `------------------- City Of Edmonds Building Department Work INTERIOR REMODEL Address 20805 77TH PL W Owner'-------------------------------GUIRL ------------------ ------------------- Approved Date 07/28/2022 Building Official lrelpl�'61,9,9N E Permit Number It 1�:?j a' 36'-4" FRONT YARD /KIM / 1 IAAIrr\ A1.0 SITE PLAN, PROJECT DATA, NOTES A2.0 PLANS CONTACTS OWNER JAMES GUIRL 20805 77TH PL W EDMONDS, WA 98026 425-941-0174 ARCHITECT EK ARCHITECTURE ESTER KATSAROS 5531 34TH AVE NE SEATTLE WA 98105 206-724-9415 PROJECT INFORMATION SITE ADDRESS 20805 77TH PL. W EDMONDS, WA 98026 SCOPE OF WORK INTERIOR REMODEL: RE -PURPOSE UNHEATED STORAGE TO POWDER ROOM & LAUNDRY ROOM, UPDATE KITCHEN AND EXISTING BATHROOM. (NO EXTERIOR WORK) LEGAL DESCRIPTION TERRA PARK 5 BLK OOOD-00- LOT 13 TAX LOT NUMBER 005958-000-013-00 CONSTRUCTION TYPE VB OCCUPANCY R-3 ZONING RS8 HEATED AREA HEATED AREA: EXISTING MAIN FLOOR: 1173 SF NEW HEATED: 32 SF TOTAL SITE PLAN NORTH SCALE: 1" = 20'-0" 0 10 20 30 40 1,205 SF 64'-2" REAR YARD (NfI f HANr_,F) M. F El EKI ARCHITECTURE ARCHITECT: EK ARCHITECTURE Ester Katsaros 5531 34th Ave N E Seattle, WA 98105 206-724-9415 ester@E-Karchitecture.com CLIENT: JAMES GUIRL 20805 77TH PL W EDMONDS WA 98026 425-941-0174 11703 REGISTERED ARCHITECT E TE KA AROS STATE OF WASHINGTON LU C) N O 00 75; 3: 0-) Lu _ja ti 0 r--- z -LoO 0 0 N o LOU DATE: 30 JUNE 2022 RECEIVED Jul 06 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SITE PLAN & NOTES A1.0 Q _E1 EXISTING CAR PORT x EXISTING Q FLOOR PLAN NORTH SCALE: 1/4" = V-0" w w EXISTING CAR PORT NEW INSULATED DOOR TO REPLACE DOOR AT EXISTING DOOR OPENING ADD INSULATION AS REQUIRED PER SECTION R503.1. ALTERATIONS, BUILDING ENVELOPE, SHALL COMPLY ENERGY CODE R402 EXCEPTION, EXISTING CEILING, FLOOR CAVITIES EXPOSED DURING CONSTRUCTION PROVIDED THESE CAVITIES ARE FILLED WITH INSULA 2X4 FRAMED WALLS WITH R-15 AND 2X6 WALLS WITH LEGEND SD SMOKE DETECTORS CO CARBON MONOXIDE DETECTORS 00 EXHAUSTFAN (E) EXISTING (N) NEW NEW WALLS EXISTING WALLS O DEMO WALLS I-- ELEC PANEL Q PROPOSED FL NORTH SCALE: 1/4" = V-0" OOR PLAN NEW KITCHEN CABINETS PER OWNER DEMO WALLS, TYP. NEW MINI- SPLIT HEAT PUMP MIN HSPF 10.0 (USED FOR ENERGY CREDITS) F El EKI ARCHITECTURE ARCHITECT: EK ARCHITECTURE Ester Katsaros 5531 34th Ave N E Seattle, WA 98105 206-724-9415 ester@E-Karchitecture.com CLIENT: JAMES GUIRL 20805 77TH PL W EDMONDS WA 98026 425-941-0174 117fl=K4ROS STATE OF WASHINGTON LU C) N 0 M TW W ^J a I..L J ~ U) d 70 7 — o0 0 C 0 N W DATE: 30 JUNE 2022 RECEIVED Jul 06 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PLANS A2.0