Loading...
ENG2022-0613 ROW PERMIToff' EIDM OF WAY EUC PERMIT o �~ ok_ City of Edmonds PERMIT NUMRIGHT f Edmonds98020 1 1. www.edmondswa.gov i Description: ZIPLY - PULL NEW FIBER THROUGH EXISTING CONDUIT ISSUED: 02/06/2023 Address: 18212 76TH AVE W EDMONDS WA 98026-5408 EXPIRES:08/06/2023 Permit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00822600000100 CONTACTS NAME TYPE NAME ADDRESS PHONE APPLICANT ARIANNE COMER 1800 41ST STREET STE N-100, EVERETT WA 98230 (830)513-6614 CONTACT ZIPLY FIBER 1800 41ST STREET STE N-100, EVERETT WA 98230 (830)513-6614 CONTRACTOR ZIPLY FIBER 1800 41ST ST, EVERETT WA 98201 (425)949-0230 OWNER DEVIN & HEATHER TURNER 18212 76TH AVE W, EDMONDS WA 98026 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00 ENGINEERING INSPECTION FEE $110.00 $110.00 RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $330.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. RELEASED BY: MAJ DATE: 02/06/2023 Printed: Monday, February 06, 2023 1:02:17 PM 1 of 2 RIGHT PERMIT PERMIT NUM City of Edmonds Edmonds WA 98020 • www.edmondswa.gov / 425.1 1 CONDITIONS CONDITION TYPE NOTES ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on SOUND AND NOISE weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT NOTES COMPLETE A-1 JOB START E-7 TRAFFIC CTRL X-2 ENGINEERING FINAL" Printed: Monday, February 06, 2023 1:02:17 PM 2 of 2 RECEIVED Lti�y of EpiyO�o� ANC. 1 g90 SECTION A RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal Requirements outlined in Right -of -Way permit Handout E63. JAN 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A" instead of leaving blank. All fields required. Incomplete Applications will be denied. General Info Project Name 162035 Site Address or if no site address use Property Address at NW corner of project area: • 5 A yV �h A/ Associated Permits: BLD PLN ENG Owner and Entity Holding Name of Company Ziply Fiber Northwest, LLC Franchise Ordinance No: WN U-17 Point of Contact Mike Hakahan Title Engineer Address1800 41 st St., Ste. N 100 city Everett State WA zip 98203 Phone 425-949-0230 Email mike.hakahan@ziply.com Contractor and Authorized Agent of Owner (see note below) Name of Company Ziply Fiber Northwest, LLC Contractor Contacts During Construction Primary Name Mike Hakahan Agent Name Mike Hakahan Title Engineer Title Engineer Mobile 425-949-0230 Address1800 41st St. Ste. N100 Email mike.hakahan@ziply.com City Everett I state WA zip 98203 Secondary Name Phone 425-949-0230 Title Email mike.hakahan@ziply.com Mobile City of Edmonds Business License No: 313-013-420 Email state License No: ZIPLY*800L5 ID Contractor verifies it is currently bonded Contractor verifies it currently has general liability insurance 1VU1h: 1 CDC 18.60.020 requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as well) ❑ Traffic Control Only (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 m Utility Franchise Work (no associated development) Project Description Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Telecommunications & broadband provider Ziply Fiber to access flower pot then pull fiber to terminal approx. 80' RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF JxJ LF SF Alley 72 hours + LF JxJ F SF Parking 72 hours + LF JxJ LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: * telecommunications ❑ cable ❑ power ❑ gas ❑ water ❑ sewer ❑ storm 1. CompletedDetails of Work to be Does the utility owner have existin overhead infrastructure in the area of work? • X 2. Will any equipment be added underground or above ground (e.g. pedestals, vaults, etc.)? X If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility system? X 5. Does the work involve proposed additions to an aboveground utility system? If es: X Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? Details of • to be Completed ®i 6. Does your project involve rebuilding or replacing utility equipment which currently serves more X than one lot or commercial development? City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 If yes, answer the following questions related to project area, i.e. the actual area in which the project is proposed: 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? 1 1 1 How many are to be added? o 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? What is the height of the existing poles? How many poles are to be removed? Are additional poles to be laced? How many? What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? I I What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: DATE: APPLICANT PRINTED NAME: M N APPLICANT TITLE: FJ NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 LEGEND: El EXISTING TERMINAL FIRM PROPOSED TERMINAL ® EXISTING UTILITY POLE ® PROPOSED NEW POLE H 7 1 EXISTING HANDHOLE H 7 1 PROPOSED NEW HANDHOLE [2'x3'] M H EXISTING MANHOLE EH PROPOSED NEW MANHOLE 0 EXISTING FLOWER POT ® PROPOSED NEW FLOWER POT — — — — — — EXISTING UNDERGROUND UTILITY PROPOSED UNDERGROUND — — — — — — CONSTRUCTION [HAND DIG, BORE] EXISTING AERIAL SPAN PROPOSED AERIAL SPAN — CENTER LINE — — PARCEL LIMITS [PROPERTY LINE] EOP EDGE OF PAVEMENT ROW RIGHT OF WAY WORK DETAILS: ACCESS FLOWER POT THEN PULL FIBER TO TERMINAL APPR❑X, 80', THEN HAND DIG TO CUSTOMER APPR❑X, 35' TRENCH IN UNPAVED AREA TRENCH IN PAVED AREA I REQUIRED PAVEMENT RESTORATION SEE MILL CREEK STD. PLANS OR AS SPECIFIED SAYYCUTITYP)APPLYJOINT SURFACE RESTORATION AS SPECIFIED 1Y MIN. SEA UWT PG 84-22 TO TOP AND TACK COATTOSIOES MOUND4"MIN.-I EXISTING PAVEMENT SURFACE SELECT ORNATIVETRENCH aW — NEAT-UNETRENCH(TYP) WHEN BACKFI COMPACT TO 96460E < MAX. DRY DENSITY(PERASTM 48"MIN. DEPTH IS LESS TRAIN IS" D1S67) IN UNPAVED AREA Q 'CRUSHED SURFACING TOP i FOR a a BENCH AS NEEDED COURSE' PER WSDDT STD SHORING OR THE NCH SPEC 9.639(3). COMPACT TO B9% S SOX 0I WHET! DEPTH MAXDRY DENSITY, SEE NOTE 2 ',R IS WAND GREATER ��� �� 3, SELECT-NATIVETRENCH BACKFILLOOMPAOTT095% INITIAL NATIVE RACKF1U_ _ MAX. DRY DENSITY (PER SELECT (MAX I- ROCK) MATERIAL =- _ - ASTM D1557) IN PAVED COMPACTED TO 06%MAX. DRY - - - AREA. PLACED IN 12" MAX LIFTS. DENSITY, W MAX. LOOSE UFTS GRAVEL SACKFILL FOR PIPE ZONE 2 L MINI T MIN BEDDING PER WSDOT BU3.12 (3) VARIES ----I Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. q 1 fl 2' 14 30, .i I I r M 18301 . ! ATCOCOMMIUNICATIONS SERVICES. LLC "I www.atcotelecom.com 360.563.9000 1 708 First Street _ Snohomish, WA 98290 II_ ---- ■ 1,9209 ENGINEERING DIVISION ...,7TED 12/02/202 APPROVAL FOR PULLING THROUGH EXISTING CONE M IN ML =e" RECEIVED` JI A- nsa-6c . OWNER/CONTRACTOR IS RESPONSIBLE FOR OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING JAN 03 2023 EROSION CONTROL AND DRAINAGE ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. CITY OF EDMONDS DEVELOPMENT zipyEIfiber verett, WA 98206 a a o 3 0 0 d O O LO � � M 0 0 C4 W w � i i > z a a N N Q__ 0 U 0 z Q LLI Z 0 a z O O U LU of of OJ LL d d DATE: 12.27.2022 DESIGNED BY: L. MATEO ATCO CONTACT: 916.202.7699 Iance.mateo@atcotelecom.com SCALE: NOT TO SCALE SHEET: 0' N0: 1 OF SERVICES DEPARTMENT ATCO COMMUNICATIONS SERVICES, LLC AS THE DESIGNER OF THIS TRAFFIC CONTROL PLAN, MAKES NO REPRESENTATION AS TO ITS' GENERAL ADEQUACY OR BEING APPROVED FOR IMPLEMENTATION. APPROVAL MUST RESULT FROM THE TRAFFIC ENGINEER OR OTHER PUBLIC OFFICIAL HAVING STATUTORY ENFORCEMENT AUTHORITY IN THE JURISDICTION. UTILIZATION AND IMPLEMENTATION OF THIS PLAN SHALL BE A RESULT OF THE APPROVAL. REF. MUTCD 2009 6A - 01 (10) r 4, t rl Q r fr , 0, , r YY� _ Southwest -_�-_-County Park 03 cy 3 180th Pi SW 19 Elroi Adult Family Home PR 184th St SW Seaview Park Seaview Park Pickleball and Tennis courts 186th St SW s E2 Bi keIhAe path 9 178th PI SIN 180th St SW Babysteps Ministry Aishinkai 19 h WORK AREA United States Postal Service Bistro 76 Cafe & Cate5ing 9 Nomad Games v and Hobbies toyv t)T Olympic View Senior Care w CL I� (D R Jim Robinson's DAR Services 182nd St SW V O. Q > ,judge Way Lynndalle Off -leash Dag Area N 6 A" O ATCO COMMWNICARONSSERVICES. LLC 177th St SW www.atcotelecom.com 360.563.9000 708 First Street Snohomish, WA 98290 9 Houst zipyEIf i b e r verett, WA 98206 180th St SW co � 3 (n CL O O O CL M O CUj W N Atl a I L-I--I W N N L EV co ASSOLLJ C/) O U U U) til O`er` m w � � o CL z F_ F_ Z o a a z a a 0 _j Lynndale Park Skate Park (r a s.-`�t ,Y0[ymp�G c V ti (D ' i ,r (D VICINITY MAP DATE: 12.27.2022 REVIEWED BY: D. LAFLEUR WSTCS# 013259 DESIGNED BY: L. MATEO RECEIVED ATCO CONTACT: 916.202.7699 Iance.mateo@atcotelecom.com JAN 03 2023 SCALE: SHEET: CITY OF EDMONDS NOT TO SCALE O DEVELOPMENT SERVICES DEPARTMENT NO: 1 OF 2 LEGEND: OSIGNALIZED INTERSECTION OCONE (CANDLESTICK) ® TYPE III BARRICADE WORK TRUCK WORK ZONE LIMITS WARNING SIGN ARROW BOARD E (WHERE REQUIRED) DIRECTION OF TRAFFIC (NOT PAVEMENT MARKINGS) FLAGGER (AS NEEDED) 76TH AVE W (25 MPH) W20-1 SIGN LEGEND: ROAD ONE LANE WORK ROAD AHEAD AHEAD W20-1 W20-4 W3-4 W20-7A ATCO COMMUNICATIONS SERVICES, LLC AS THE DESIGNER OF THIS TRAFFIC CONTROL PLAN, OAKES NO REPRESENTATION AS TO ITS' GENERAL ADEQUACY OR BEING APPROVED FOR IMPLEMENTATION APPROVAL MUST RESULT FROM THE TRAFFIC ENGINEER OR OTHER PUBLIC OFFICIAL HAVING STATUTORY ENFORCEMENT AUTHORITY IN THE JURISDICTION. UTILIZATION AND IMPLEMENTATION OF THIS PLAN SHALL BE A RESULT OF THE APPROVAL. REF. MUTCD 2009 6A - 01 (10) 7A TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP 50'-100' ONE LANE, TWO WAY TRAFFIC TAPER SIDEWALK • 50'-100' 18 ONE LANE, TWO WAY WORK TRAFFIC AREA ) TAPER 13 DRIVEWAY 10' MIN. DRIVEWA Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. BUFFER AREA LONGITUDINAL BUFFER SPACE = B POSTED SPEED (MPH) 25 30 35 40 45 50 55 60 64 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TRANSPORTABLE ATTENUATOR ROLL AHEAD DEVICE = R HOST VEHICLE WEIGHT (Ibs) 9,900 TO 22,000 HOST VEHICLE WEIGHT (Ibs) > 22,000 < 45 MPH 45 - 55 MPH > 55 MPH < 45 MPH 45 - 55 MPH > 55 MPH 100, 123' 172' 74' 100, 150' NOTE: MON. - FRI. = 7:00am TO 4:00pm W20-7 RECEIVED JAN 03 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT CHANNELIZATION DEVICE SPACING (feet) MPH TAPER TANGENT 50/70 40 80 35/45 30 60 25 Tin 20 40 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) SHOULDER POSTED SPEED (MPH) WIDTH (feet) 25 30 35 40 45 50 55 60 65 70 8 40 40 60 90 120 130 150 160 170 190 10 40 60 90 90 150 170 190 220 220 240 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THAN 8' PHASE 1 Q' Z ENGINEERING DIVISION ...,7TED � (;_ (w 12/02/2022 APPROVAL FOR PULLING THROUGH EXISTING CONDUIT ONLY. ANY BORING OR EXCAVATING SHALL REQUIRE REVISION TO PERMIT. W20— SIDEWALK WORK DETAILS. - W20-1 ACCESS FLOWER POT THEN PULL FIBER TO TERMINAL APPR❑X, 80' SPOTTER NEEDED FOR PEDESTRIAN TRAFFIC AND DRIVEWAY ACCESS, SIGN SPACING = X (1) FREEWAY & EXPRESSWAYS 55 / 70 MPH 1500' ± RURAL HIGHWAYS 60 / 65 MPH 800' ± RURAL ROADS 45 / 55 MPH 500' ± RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' ± RURAL ROADS & URBAN ARTERIALS 25 / 30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200' ± (2) URBAN STREETS 25 MPH OR LESS 100' ± (2) (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT -GRADE INTERSECTIONS AND DRIVEWAYS (2) THIS SPACE MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. 0 ATCOCOMMWNICATIONSSERVICES. LLC www.atcotel•com.com 360.563.9000 708 First Street Snohomish, WA 98290 zipyEIfiber verett, WA 98206 U-) N < < � Z � Z z D: U O 2 O 2 LO Q o LU w N 12 < < (.0 (.0 O N N N_ N W W I- z O U U W U) w LL mQ o z F_ z 0 z of a of o- O J J LL DATE: 12.27.2022 REVIEWED BY: D. LAFLEUR WSTCS# 013259 DESIGNED BY: L. MATEO ATCO CONTACT: 916.202.7699 Iance.mateo@atcotelecom.com SCALE: SHEET: 22 NO: 2OF2