ENG2022-0613 ROW PERMIToff' EIDM
OF WAY EUC PERMIT
o
�~ ok_
City of Edmonds PERMIT NUMRIGHT
f
Edmonds98020 1 1.
www.edmondswa.gov i
Description: ZIPLY - PULL NEW FIBER THROUGH EXISTING CONDUIT
ISSUED: 02/06/2023
Address: 18212 76TH AVE W EDMONDS WA 98026-5408
EXPIRES:08/06/2023
Permit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00822600000100
CONTACTS
NAME TYPE NAME ADDRESS PHONE
APPLICANT ARIANNE COMER 1800 41ST STREET STE N-100, EVERETT WA 98230 (830)513-6614
CONTACT ZIPLY FIBER 1800 41ST STREET STE N-100, EVERETT WA 98230 (830)513-6614
CONTRACTOR ZIPLY FIBER 1800 41ST ST, EVERETT WA 98201 (425)949-0230
OWNER DEVIN & HEATHER TURNER 18212 76TH AVE W, EDMONDS WA 98026
FEE INFORMATION
DESCRIPTION AMOUNT PAID
CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00
ENGINEERING INSPECTION FEE $110.00 $110.00
RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $330.00
REQUIREMENTS
REQUIREMENT TYPE NOTES
TRAFFIC CONTROL
Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification
verifying completion of the required training in their posession.
RESTORATION
Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with
asphalt or City approved material prior to the end of the workday - No Exceptions
WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final
inspection and acceptance of the work.
INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM
24 HR NOTICE REQUIRED
INDEMNITY
The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of
any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its
departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney
fees by reason of granting this permit.
RELEASED BY: MAJ DATE: 02/06/2023
Printed: Monday, February 06, 2023 1:02:17 PM 1 of 2
RIGHT PERMIT
PERMIT NUM
City of Edmonds
Edmonds WA 98020 •
www.edmondswa.gov / 425.1 1
CONDITIONS
CONDITION TYPE
NOTES
ALERT RESIDENTS
ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START.
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD
ESC REQUIREMENTS
REQUIREMENTS.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to
indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and
agents from any and all claims for damages of whatever nature, arising directly or indirectly from the
HOLD HARMLESS
issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any
requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT.
INSPECTIONS
www.mybuildingpermit.com
POTHOLING
VERIFY CLEAR BORE CROSSINGS.
RESTORE LANDSCAPE
Restore landscape to like or better conditions
Sound or noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on
SOUND AND NOISE
weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites and activities must comply with the noise
limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
INSPECTIONS
INSPECTION TYPE
DATE
RESULT
NOTES
COMPLETE
A-1 JOB START
E-7 TRAFFIC CTRL
X-2 ENGINEERING FINAL"
Printed: Monday, February 06, 2023 1:02:17 PM 2 of 2
RECEIVED
Lti�y of EpiyO�o�
ANC. 1 g90
SECTION A
RIGHT OF WAY CONSTRUCTION
PERMIT APPLICATION
Complete and submit this Application in accordance with the Submittal
Requirements outlined in Right -of -Way permit Handout E63.
JAN 03 2023
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
If any field is not applicable to your project, write "N/A" instead of leaving blank.
All fields required. Incomplete Applications will be denied.
General Info
Project Name 162035
Site Address or if no site address use Property Address at NW corner of project area: • 5 A yV �h A/
Associated Permits: BLD PLN ENG
Owner and Entity Holding
Name of Company Ziply Fiber Northwest, LLC Franchise Ordinance No: WN U-17
Point of Contact Mike Hakahan
Title Engineer
Address1800 41 st St., Ste. N 100
city Everett
State WA
zip 98203
Phone 425-949-0230
Email mike.hakahan@ziply.com
Contractor and Authorized Agent of Owner (see note below)
Name of Company Ziply Fiber Northwest, LLC
Contractor Contacts During Construction
Primary Name Mike Hakahan
Agent Name Mike Hakahan
Title Engineer
Title Engineer
Mobile 425-949-0230
Address1800 41st St. Ste. N100
Email mike.hakahan@ziply.com
City Everett
I state WA
zip 98203
Secondary Name
Phone 425-949-0230
Title
Email mike.hakahan@ziply.com
Mobile
City of Edmonds Business License No: 313-013-420
Email
state License No: ZIPLY*800L5
ID Contractor verifies it is currently bonded
Contractor verifies it currently has general liability insurance
1VU1h: 1 CDC 18.60.020 requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city
engineer.
❑ Multifamily residential ❑ Commercial ❑ City project
❑ Single family residential subdivision ❑ Single family -other ❑ Industrial
❑ Demo and rebuild or from vacant land?
❑ Other, please specify:
❑ Utility Franchise Work associated with development (check one of the above boxes as well)
❑ Traffic Control Only (no associated development)
City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021
m Utility Franchise Work (no associated development)
Project Description
Include an overall narrative description of the proposed work. Be specific and detailed:
Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc.
Include whether this is construction, maintenance, or repair.
Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for
underground utilities, etc.)
Telecommunications & broadband provider Ziply Fiber to access flower pot then pull fiber to terminal approx. 80'
RIGHT-OF-WAY
CLOSURE
AREA
TOTAL
DURATION
(Number of Months)
Sidewalk 72 hours +
LF
JxJ
LF
SF
Alley 72 hours +
LF
JxJ
F
SF
Parking 72 hours +
LF
JxJ
LF
SF
SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C.
1. The work in the right of way is on or for the following type of facilities:
* telecommunications ❑ cable ❑ power ❑ gas
❑ water ❑ sewer ❑ storm
1.
CompletedDetails of Work to be
Does the utility owner have existin overhead infrastructure in the area of work?
•
X
2.
Will any equipment be added underground or above ground (e.g. pedestals, vaults, etc.)?
X
If yes, describe:
3.
Does the proposed work connect a lot or commercial development with utilities that serve more
than one lot or commercial development?
X
4.
Does the work involve rebuilding or relocating an existing aboveground utility system which
connects a lot or commercial development to an existing underground common utility system?
X
5.
Does the work involve proposed additions to an aboveground utility system? If es:
X
Are the additions for the purpose of serving new commercial development?
Are the additions for the purpose of serving a single-family residential subdivision?
Details of • to be Completed
®i
6. Does your project involve rebuilding or replacing utility equipment which currently serves more
X
than one lot or commercial development?
City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021
If yes, answer the following questions related to project area, i.e. the actual area in which the
project is proposed:
6a.
Does your project involve wires/cables/lines? If yes:
X
How many are existing? 1 1 1 How many are to be added? o
6b.
Does your project involve poles? If yes:
X
How many poles are existing in the project area?
What is the height of the existing poles?
How many poles are to be removed?
Are additional poles to be laced?
How many? What is the height of the additionalpoles?
6c.
Are any poles to be modified/rebuilt/replaced? If yes:
X
How many? I I What is the height of the poles after?
Describe the modification rebuild:
SECTION C
Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as
required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have
certification verifying completion of the required training in their possession.
Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS.
Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to
any permit approval.
Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials,
officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever,
foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or
omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose
acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and
specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any
respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the
expiration, revocation, or termination of any resulting permit approval.
Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and
requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to
the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal
Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable
requirements of state and federal law.
Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a
licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by
owner to act on its behalf and have authority to bind the owner to this application.
Fees. The Applicant is responsible for all permit fees.
APPLICANT SIGNATURE: DATE:
APPLICANT PRINTED NAME: M N
APPLICANT TITLE: FJ
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021
LEGEND:
El
EXISTING TERMINAL
FIRM
PROPOSED TERMINAL
®
EXISTING UTILITY POLE
®
PROPOSED NEW POLE
H 7 1
EXISTING HANDHOLE
H 7 1
PROPOSED NEW HANDHOLE [2'x3']
M H
EXISTING MANHOLE
EH
PROPOSED NEW MANHOLE
0
EXISTING FLOWER POT
®
PROPOSED NEW FLOWER POT
— — — — —
— EXISTING UNDERGROUND UTILITY
PROPOSED UNDERGROUND
— — — — —
— CONSTRUCTION [HAND DIG, BORE]
EXISTING AERIAL SPAN
PROPOSED AERIAL SPAN
—
CENTER LINE
— —
PARCEL LIMITS [PROPERTY LINE]
EOP
EDGE OF PAVEMENT
ROW
RIGHT OF WAY
WORK DETAILS:
ACCESS FLOWER POT THEN PULL
FIBER TO TERMINAL APPR❑X, 80', THEN
HAND DIG TO CUSTOMER APPR❑X, 35'
TRENCH IN UNPAVED AREA TRENCH IN PAVED AREA
I
REQUIRED PAVEMENT RESTORATION
SEE MILL CREEK STD. PLANS OR AS SPECIFIED
SAYYCUTITYP)APPLYJOINT
SURFACE RESTORATION AS SPECIFIED
1Y MIN.
SEA UWT PG 84-22 TO TOP
AND TACK COATTOSIOES
MOUND4"MIN.-I
EXISTING PAVEMENT SURFACE
SELECT ORNATIVETRENCH
aW —
NEAT-UNETRENCH(TYP) WHEN
BACKFI COMPACT TO 96460E
< MAX. DRY DENSITY(PERASTM
48"MIN.
DEPTH IS LESS TRAIN IS"
D1S67) IN UNPAVED AREA
Q
'CRUSHED SURFACING TOP
i FOR
a a BENCH AS NEEDED
COURSE' PER WSDDT STD
SHORING OR THE NCH
SPEC 9.639(3). COMPACT TO B9%
S SOX 0I WHET! DEPTH
MAXDRY DENSITY, SEE NOTE 2
',R IS WAND GREATER
���
�� 3,
SELECT-NATIVETRENCH
BACKFILLOOMPAOTT095%
INITIAL NATIVE RACKF1U_
_
MAX. DRY DENSITY (PER
SELECT (MAX I- ROCK) MATERIAL =-
_ -
ASTM D1557) IN PAVED
COMPACTED TO 06%MAX. DRY - - -
AREA. PLACED IN 12" MAX LIFTS.
DENSITY, W MAX. LOOSE UFTS
GRAVEL SACKFILL FOR PIPE ZONE 2 L
MINI
T
MIN
BEDDING PER WSDOT BU3.12 (3) VARIES
----I
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or
occurs during the permitted project.
q
1 fl 2' 14
30,
.i
I
I
r
M
18301
. !
ATCOCOMMIUNICATIONS SERVICES. LLC
"I
www.atcotelecom.com
360.563.9000
1
708 First Street
_
Snohomish, WA 98290
II_ ---- ■
1,9209
ENGINEERING DIVISION
...,7TED
12/02/202
APPROVAL FOR PULLING
THROUGH EXISTING CONE
M IN ML =e" RECEIVED`
JI A- nsa-6c .
OWNER/CONTRACTOR IS RESPONSIBLE FOR OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING JAN 03 2023
EROSION CONTROL AND DRAINAGE ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
UTILITIES MAY REQUIRE A SEPERATE PERMIT.
CITY OF EDMONDS
DEVELOPMENT
zipyEIfiber
verett, WA 98206
a a
o 3
0 0
d
O O LO
� � M
0 0 C4
W w �
i i
> z
a a
N N Q__
0
U
0
z
Q
LLI
Z
0
a
z
O
O
U
LU
of
of
OJ
LL
d
d
DATE:
12.27.2022
DESIGNED BY:
L. MATEO
ATCO CONTACT: 916.202.7699
Iance.mateo@atcotelecom.com
SCALE:
NOT TO
SCALE
SHEET:
0'
N0: 1 OF
SERVICES DEPARTMENT
ATCO COMMUNICATIONS SERVICES, LLC AS THE DESIGNER OF THIS TRAFFIC CONTROL PLAN,
MAKES NO REPRESENTATION AS TO ITS' GENERAL ADEQUACY OR BEING APPROVED FOR IMPLEMENTATION.
APPROVAL MUST RESULT FROM THE TRAFFIC ENGINEER OR OTHER PUBLIC OFFICIAL HAVING STATUTORY
ENFORCEMENT AUTHORITY IN THE JURISDICTION. UTILIZATION AND IMPLEMENTATION OF THIS PLAN
SHALL BE A RESULT OF THE APPROVAL. REF. MUTCD 2009 6A - 01 (10)
r
4, t
rl Q r fr , 0, ,
r YY�
_ Southwest
-_�-_-County Park
03
cy
3
180th Pi SW
19 Elroi Adult Family Home
PR
184th St SW
Seaview Park
Seaview Park Pickleball
and Tennis courts
186th St SW
s
E2
Bi keIhAe path 9
178th PI SIN
180th St SW
Babysteps Ministry
Aishinkai 19
h
WORK AREA
United States
Postal Service
Bistro 76 Cafe & Cate5ing 9
Nomad Games v
and Hobbies
toyv t)T
Olympic View
Senior Care
w
CL
I�
(D
R
Jim Robinson's
DAR Services
182nd St SW
V
O.
Q >
,judge Way
Lynndalle Off -leash
Dag Area
N
6 A"
O
ATCO COMMWNICARONSSERVICES. LLC
177th St SW www.atcotelecom.com
360.563.9000
708 First Street
Snohomish, WA 98290
9 Houst zipyEIf i b e r
verett, WA 98206
180th St SW co � 3
(n CL
O O O
CL M
O
CUj W N
Atl a I L-I--I
W
N N
L EV co
ASSOLLJ
C/)
O
U U
U)
til O`er` m w
� � o
CL z
F_ F_ Z
o a
a z
a a 0 _j
Lynndale Park Skate Park (r
a s.-`�t ,Y0[ymp�G c
V ti (D ' i ,r (D
VICINITY MAP
DATE:
12.27.2022
REVIEWED BY:
D. LAFLEUR
WSTCS# 013259
DESIGNED BY:
L. MATEO
RECEIVED
ATCO CONTACT:
916.202.7699
Iance.mateo@atcotelecom.com
JAN 03 2023
SCALE:
SHEET:
CITY OF EDMONDS
NOT TO
SCALE
O
DEVELOPMENT
SERVICES DEPARTMENT
NO: 1 OF 2
LEGEND:
OSIGNALIZED
INTERSECTION
OCONE
(CANDLESTICK)
®
TYPE III BARRICADE
WORK TRUCK
WORK ZONE LIMITS
WARNING SIGN
ARROW BOARD
E
(WHERE REQUIRED)
DIRECTION OF TRAFFIC
(NOT PAVEMENT MARKINGS)
FLAGGER
(AS NEEDED)
76TH AVE W
(25 MPH)
W20-1
SIGN LEGEND:
ROAD ONE LANE
WORK ROAD
AHEAD AHEAD
W20-1 W20-4
W3-4
W20-7A
ATCO COMMUNICATIONS SERVICES, LLC AS THE DESIGNER OF THIS TRAFFIC CONTROL PLAN,
OAKES NO REPRESENTATION AS TO ITS' GENERAL ADEQUACY OR BEING APPROVED FOR IMPLEMENTATION
APPROVAL MUST RESULT FROM THE TRAFFIC ENGINEER OR OTHER PUBLIC OFFICIAL HAVING STATUTORY
ENFORCEMENT AUTHORITY IN THE JURISDICTION. UTILIZATION AND IMPLEMENTATION OF THIS PLAN
SHALL BE A RESULT OF THE APPROVAL. REF. MUTCD 2009 6A - 01 (10)
7A
TRAFFIC CONTROL INSPECTION SHALL BE
REQUIRED WHENEVER WORK ZONE IS SET UP
50'-100'
ONE LANE,
TWO WAY
TRAFFIC
TAPER
SIDEWALK
•
50'-100'
18
ONE LANE,
TWO WAY
WORK
TRAFFIC
AREA )
TAPER
13
DRIVEWAY
10' MIN.
DRIVEWA
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or
occurs during the permitted project.
OWNER/CONTRACTOR IS RESPONSIBLE FOR
EROSION CONTROL AND DRAINAGE
OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
UTILITIES MAY REQUIRE A SEPERATE PERMIT.
BUFFER AREA
LONGITUDINAL BUFFER SPACE = B
POSTED SPEED (MPH)
25
30
35
40
45
50
55
60
64
70
LENGTH (feet)
155
200
250
305
360
425
495
570
645
730
TRANSPORTABLE ATTENUATOR ROLL AHEAD DEVICE = R
HOST VEHICLE WEIGHT (Ibs)
9,900 TO 22,000
HOST VEHICLE WEIGHT (Ibs)
> 22,000
< 45 MPH
45 - 55 MPH
> 55 MPH
< 45 MPH
45 - 55 MPH
> 55 MPH
100,
123'
172'
74'
100,
150'
NOTE:
MON. - FRI. = 7:00am TO 4:00pm
W20-7
RECEIVED
JAN 03 2023
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
CHANNELIZATION DEVICE
SPACING (feet)
MPH TAPER
TANGENT
50/70 40
80
35/45 30
60
25 Tin 20
40
MINIMUM SHOULDER TAPER LENGTH = L/3 (feet)
SHOULDER
POSTED SPEED (MPH)
WIDTH
(feet)
25
30
35
40
45
50
55
60
65
70
8
40
40
60
90
120
130
150
160
170
190
10
40
60
90
90
150
170
190
220
220
240
USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THAN 8'
PHASE 1 Q' Z
ENGINEERING DIVISION
...,7TED
� (;_ (w 12/02/2022
APPROVAL FOR PULLING
THROUGH EXISTING CONDUIT
ONLY. ANY BORING OR
EXCAVATING SHALL REQUIRE
REVISION TO PERMIT.
W20—
SIDEWALK
WORK DETAILS. -
W20-1
ACCESS FLOWER POT THEN PULL
FIBER TO TERMINAL APPR❑X, 80'
SPOTTER NEEDED FOR PEDESTRIAN
TRAFFIC AND DRIVEWAY ACCESS,
SIGN SPACING = X (1)
FREEWAY & EXPRESSWAYS 55 / 70 MPH
1500' ±
RURAL HIGHWAYS 60 / 65 MPH
800' ±
RURAL ROADS 45 / 55 MPH
500' ±
RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH
350' ±
RURAL ROADS & URBAN ARTERIALS 25 / 30 MPH
RESIDENTIAL & BUSINESS DISTRICTS
200' ± (2)
URBAN STREETS 25 MPH OR LESS
100' ± (2)
(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,
AT -GRADE INTERSECTIONS AND DRIVEWAYS
(2) THIS SPACE MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.
0
ATCOCOMMWNICATIONSSERVICES. LLC
www.atcotel•com.com
360.563.9000
708 First Street
Snohomish, WA 98290
zipyEIfiber
verett, WA 98206
U-)
N
<
<
�
Z
�
Z
z D:
U
O
2
O
2
LO
Q o
LU
w
N
12
<
<
(.0
(.0
O
N
N
N_
N
W
W
I-
z
O
U
U
W
U)
w
LL
mQ
o
z
F_
z
0
z
of
a
of
o-
O
J
J
LL
DATE: 12.27.2022
REVIEWED BY: D. LAFLEUR
WSTCS# 013259
DESIGNED BY: L. MATEO
ATCO CONTACT: 916.202.7699
Iance.mateo@atcotelecom.com
SCALE: SHEET:
22
NO: 2OF2