HVAC TI PLAN SCALE: ill = 1'
GAS -ELECTRIC PACKAGE UNIT SCHEDULE
UNIT#
BRAND
NAME
MODEL #
NOMINAL
TONS
TOTAL
CFM
ECON
CYCLE
SP
HP/
BHP
COOLING
HEATING
DBA
WEIGHT
(LBS)
ELECTRICAL
NOTES
TOTAL
BTUH
SENSIBLE
BTUH
SEER
/ EER
INPUT
(BTUH)
OUTPUT
(BTUH)
AFUE
VOLT/
PH
MCA
MAX
FUSE
RTU-1
I TRANE
4YCC4048A1090A
1 4
1 1,600
1 100%
1 .1" WC
1 0.75
1 48,000
46,500
14.0
90,000
72900
0.81
72.5
453.0
1 230/1
32
50
1
RTU-21
TRANE
14YCC406OAl115A
1 5
1 1,760 1
100%
1 .1" WC
1 1.00 1
60,000
1 58,000
14.0
115,000
1 93150
10.81173.11
482.0
230/1
139.1
1 60
1
NOTES:
1. UNIT HAS FULLY MODULATING ECONOMIZER.
SCOPE OF WORK:
REPLACE TWO ROOFTOP HVAC UNITS "LIKE -FOR -LIKE" WITH NEW UNITS OF SIMILAR CAPACITY AND HIGHER
EFFICIENCY.
UNIT WEIGHT OF OLD UNIT WEIGHT OF NEW UNIT
RTU-1 485 453
RTU-2 520 482
City Of Edmonds
Building Department
-------------
Work (2) RTU- MECHANICAL
--------------
Address
107 5TH AVE N
Owner RUSTY PELICAN
----------------------------
Approved Date: 12/30/2022
------------------------
Building Official Erit/ C,a-rfer
Permit Number BLD2022-1732
REVISIONS
DATE - PAGES - CHANGES
REV1
REV2
REV3
REW
REV5
APPROVED BY PLANNING
Dec 27 2022
RTU's 400#'s or greater shall have
engineered attachments from the unit to the
curb to prevent both wind and seismic forces.
Stamped Engineered design shall be onsite
at the time of inspection.
H.V.A.C. GENERAL NOTES
(AS APPLICABLE)
1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW THE EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC
CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK.
2. MATERIALS, METHODS AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2018 EDITIONS OF THE INTERNATIONAL
MECHANICAL CODE, INTERNATIONAL BUILDING CODE, UFC, SEATTLE MECHANICAL CODE AND OTHER LOCAL CODES AND
ORDINANCES AND THE 2018 EDITIONS OF WASHINGTON STATE ENERGY CODE AND SEATTLE ENERGY CODE. REFERENCES TO ONE
CODE SHOULD BE INTERPRETED AS ALSO APPLYING TO THE CORRESPONDING SECTION(S) OF THE MOST RESTRICTIVE CODE THAT
APPLIES.
3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH THE 2018 IMC, 2018 SMC AND WITH CURRENT SMACNA STANDARDS
EARTHQUAKE BRACE ALL DUCTS 24" DIAMETER AND LARGER WHICH ARE SUSPENDED BY HANGERS 12" OR MORE IN LENGTH.
PROVIDE EARTHQUAKE BRACING AT 30' ON CENTER MAXIMUM. FIBERGLASS DUCTBOARD SHALL NOT BE USED.
4. ALL CONCEALED DUCT SYSTEMS SHALL BE SEALED WITH LISTED MASTIC TYPE DUCT SEALANT AT ALL JOINTS. SEAL FITTINGS
CONNECTIONS WITH DUCT SEALANT (NOT TAPE). EXPOSED DUCTS SHALL BE INTERNALLY SEALED.
5. DUCTS SHALL BE INSULATED AS REQUIRED BY THE 2018 WASHINGTON STATE ENERGY CODE OR 2018 SEATTLE ENERGY CODE
-DUCT WRAP IN CEILING PLENUM SPACE SHALL BE 1.5", .75 LBICU FT FIBERGLASS DUCT INSULATION WITH A FACTORY
APPLIED REINFORCED ALUMINUM FOIL VAPOR BARRIER, MIN. R-3.3.
-DUCT WRAP FOR FRESH AIR SUPPLY DUCTS SHALL BE 2", 1.5 LBICU FT FIBERGLASS INSULATION WITH A FACTORY APPLIED
REINFORCED ALUMINUM FOIL VAPOR BARRIER. MIN. R-7.
-SOUND LINING FOR SUPPLY DUCTS WITHIN BUILDING SHALL BE 1", 1.5 LBICU FT FIBERGLASS DUCT LINING COATED TO
PREVENT FIBER EROSION AT VELOCITIES UP TO 4000 FPM. MIN. R-3.3.
-SOUND LINING FOR SUPPLY DUCTS OUTSIDE BUILDING SHALL BE 2", 1.5 LBICU FT FIBERGLASS DUCT LINING COATED TO
PREVENT FIBER EROSION AT VELOCITIES UP TO 4000 FPM. MIN. R-8.
6. PIPING SHALL BE INSULATED AS REQUIRED BY THE 2018 WASHINGTON STATE ENERGY CODE OR 2018 SEATTLE ENERGY CODE
SECTION C403.10.3.
7. FLEXIBLE DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 11/2" FIBERGLASS INSULATION (R-5) AND NON -PERFORATED
INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS I AIR DUCT. FLEXIBLE DUCTS SHALL ONLY BE USED
WHERE SHOWN AND SHALL NOT EXCEED 10' IN LENGTH UNLESS NOTED OTHERWISE. IN ROOF CEILING JOIST SPACE FLEXIBLE
DUCTS SHALL HAVE AN R-8 INSULATION RATING.
8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH THE 2018 IBC.
9. PROVIDE TURN VANES IN ALL MITERED 90'S AND TEES.
10.ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECTS, MOTOR STARTERS, OVERLOADS AND POWER WIRING AS REQUIRED TO ALL
EQUIPMENT
11.MECHANICAL CONTRACTOR SHALL PROVIDE AND MOUNT RETURN DUCT SMOKE DETECTORS CAPABLE OF AUTOMATIC SHUT DOWN
OF ALL HEATING OR COOLING EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH THE 2018 IMC OR 2018
SMC. POWER WIRING AND INTERLOCK WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL OR FIRE ALARM
CONTRACTOR. MECHANICAL CONTRACTOR SHALL PROVIDE WEATHERPROOF ENCLOSURES FOR DUCT SMOKE DETECTORS WHERE
NECESSARY ON ROOF DUCT SYSTEM. COORDINATE WITH ELECTRICAL OR FIRE ALARM CONTRACTOR.
12.MAINTAIN 10' BETWEEN OUTSIDE AIR INTAKES TO AC AND MUA UNITS AND EXHAUST FROM VENTILATION EQUIPMENT,
COMBUSTION EQUIPMENT AND PLUMBING VENTS.
13.THE MECHANICAL CONTRACTOR SHALL LABEL ALL MECHANICAL EQUIPMENT, VALVES AND PIPING. COORDINATE WITH BUILDING
ENGINEER.
14.THE MECHANICAL CONTRACTOR SHALL PROVIDE TEMPORARY FILTERS TO HVAC EQUIPMENT IN THE T.I. SPACE DURING
CONSTRUCTION TO MINIMIZE DUST INFILTRATION TO THE BUILDING H.V.A.C. SYSTEM.
15.THERMOSTATS WILL BE 7-DAY PROGRAMMABLE TYPE WITH OPTIMUM START MORNING WARMUP, NIGHT SETBACK AND
CONFIGURABLE 50F DEADBAND TO PREVENT SIMULTANEOUS HEATING AND COOLING. FOR HEAT PUMP CONTROL, THERMOSTAT
WILL USE COMPRESSOR AS FIRST STAGE WITH VISIBLE INDICATOR WHEN SUPPLEMENTARY HEAT IS USED. PER WSEC C403.4.1.1,
SUPPLEMENTARY ELECTRIC HEAT MAY NOT OPERATE WHEN OUTSIDE TEMPERATURES ARE ABOVE 400 F. PER C403.4.1.1,
SUPPLEMENTARY ELECTRIC HEAT MAY NOT OPERATE WHEN HEATING LOAD CAN BE MET WITH HEAT PUMP ALONE EXCEPT DURING
DEFROST.
16.COMBUSTION HEATING SHALL COMPLY WITH 2O18 WSEC AND 2018 SEC AND INCLUDE INTERMITTENT IGNITION AND FLUE -DRAFT
DAMPER. HEATING EQUIPMENT BELOW 225,000 BTUH TO COMPLY WITH TABLE C403.3.2(4)(MINIMUM AFUE .80).
17.ECONOMIZER AND ZONE DAMPERS SHALL MEET THE REQUIREMENTS OF 2018 WSEC OR 2018 SEC FOR DAMPER LEAKAGE AND
CONTROL:
-OA SUPPLY DAMPER(S) SHALL AUTOMATICALLY CLOSE DURING UNOCCUPIED PERIODS, DURING MORNING WARMUP AND WHEN
UNIT IS OFF.
-OA SUPPLY DAMPER(S) ARE ALLOWED TO OPEN FOR ONE HOUR PRIOR TO OCCUPANCY.
-OA SUPPLY DAMPER(S) SHALL COMPLY WITH AMCA STANDARD 500 FOR MAXIMUM ALLOWABLE LEAKAGE.
18.MECHANICAL CONTRACTOR WILL PROVIDE MECHANICAL SYSTEM COMMISSIONING AND COMPLETION AS REQUIRED BY THE WSEC
C408 OR SEC C408
19.THE HEATING AND COOLING EQUIPMENT FOR THIS PROJECT IS SIZED WITHIN THE ALLOWABLE LIMITS REQUIRED BY WSEC C403.3.1
OR SEC C403.3.1 HEATING AND COOLING CAPACITIES DO NOT EXCEED LOADS BY 50%. (LOAD CALC'S ATTACHED)
20.THIS IS A LOW-PRESSURE DUCT SYSTEM (2" W.C. OR LESS). THE CONTRACTOR WILL SEAL DUCTWORK IN COMPLIANCE WITH WSEC
C403.10.2 OR SEC C403.10.2.
21.13ALANCING DAMPERS WILL BE INSTALLED ON ALL SUPPLY DIFFUSERS.
H.V.A.C. STANDARD ABBREVIATIONS
A
COMPRESSED AIR LINE
ESP
EXTERNAL STATIC PRESSURE OSA
OUTSIDE AIR
AC
AIR CONDITIONING UNIT
EXH
EXHAUST
OBD
OPPOSED BLADE DAMPER
AFF
ABOVE FINISHED FLOOR
FD
FIRE DAMPER
OD
OUTSIDE DIMENSION
BDD
BACKDRAFT DAMPER
FLA
FULL LOAD AMPS
PD
PRESSURE DROP
BOD
BOTTOM OF DUCT
FOB
FLAT ON BOTTOM
RA
RETURN AIR
BOTT
BOTTOM
FOT
FLAT ON TOP
REG
REGISTER (GRILL WIDAMPER)
BTU
BRITISH THERMAL UNIT
G
GAS LINE (LOW PRESSURE)
REWD
REQUIRED
BTUH
BRITISH THERMAL UNIT PER HOUR
GALV
GALVANIZED
RIO
ROUGH IN ONLY
BWG
BOTTOM WALL GRILL
GC
GENERAL CONTRACTOR
SA
SUPPLY AIR
BWR
BOTTOM WALL REGISTER
GPM
GALLONS PER MINUTE
SL
SOUND LINING
CAP
CAPACITY
HG
HOT GAS LINE
SM
SHEET METAL
CFM
CUBIC FEET PER MINUTE
ID
INSIDE DIMENSION
SP
STATIC PRESSURE
COMB
COMBUSTION
MBH
THOUSAND BTUH
SS
STAINLESS STEEL
DB
DUCT BOARD
MC
MECHANICAL CONTRACTOR
TOD
TOP OF DUCT
DMPR
DAMPER
MIN
MINIMUM
TWG
TOP WALL GRILL
ON
DOWN
MPG
MEDIUM PRESSURE GAS
TWR
TOP WALL REGISTER
EC
EGGCRATE
MT
MOUNT
TYP
TYPICAL
ELEV
ELEVATION
NOM
NOMINAL
UNO
UNLESS NOTED OTHERWISE
VICINITY MAP
D yao. t
Heattransfer Co.
P.O. Box 1268
Carnation, WA 98014-1268
PH: (425)885-3247
FX: (425)333-6545
Contractor # HEATT**20600
Electrical # HEATTC*009DA
DRAWING
DRAWN: RS
CHECKED: TM
DATE: 12120/2022 ISSUED
HVAC LEGENDS,
NOTES, ELEV. PLAN,
FLOOR PLANS AND
SCHEDULES
RUSTY PELLICAN
107 - 5TH AVE NORTH
EDMONDS, WA
PARCEL NUMBER
00434400100101
LEGAL DESCRIPTION
SW114 SEC24 T27N R3E
EDMONDS PLAT OF BLK 001
D-01 - ELY 80FT OF LOTS 1 &
2
BLD2022-1732
RECEIVED
Dec 20 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
M - 1
SHEET N0.