Loading...
REVIEWED BLD2022-1732+Manufacturer_Specifications_and_Installation_Instructions+12.20.2022_2.53.36_PM+3278813Submittal Single Packaged Convertible Gas/Electric 14 SEER 4YCC406OAl 1 15A RECEIVED Dec 20 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-1732 REVIEWED BY CITY OF EDMONDS June 2020 4YCC406OA-SU13-1 F-EN SAFETY SECTION Important — This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please return to service information pack upon completion of work. HAZARDOUS GASES! Exposure to fuel substances or by-products of incomplete fuel combustion is believed by the state of California to cause cancer, birth defects, or other reproductive harm. This warning complies with state of California law, Proposition 65. HAZARDOUS VOLTAGE! Failure to follow this Warning could result in property damage, severe personal injury, or death. Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized. SAFETY AND ELECTRICAL HAZARD! Failure to follow this Warning could result in property damage, severe personal injury, or death. These servicing instructions are for use by qualified personnel only. To reduce the risk of electrical shock, do not perform any servicing other than that contained in these operating instructions unless you are qualified to do so. GROUNDING REQUIRED! Failure to inspect or use proper service tools may result in equipment damage or personal injury. Reconnect all grounding devices. All parts of this product that are capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts, or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened. UNIT CONTAINS R-410A REFRIGERANT! Failure to use proper service tools may result in equipment damage or personal injury. R-410A operating pressure exceeds the limit of R- 22. Proper service equipment is required. Service using only R-410A Refrigerant and approved POE compressor oil. SAFETY HAZARD! Operating the unit without the access panels properly installed may result in severe personal injury or death. Do not operate the unit without the evaporator fan access panel or evaporator coil access panel in place. 111i\ \ This product can expose you to chemicals including lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. Important. Wear appropriate gloves, arm sleeve protectors and eye protection when servicing or maintaining this equipment. Important. Air filters and media wheels or plates shall meet the test requirements in UL 900. ©2020 4YCC4060A-SUB-1 F-E N Product Specifications MODEL 4YCC406OA1115A RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 Performance Cooling BTU (a) 58000 58000 Indoor Airflow (CFM) 1760 1760 Power Input (KW) 4.94 4.94 EER/SEER (BTU/Watt- 11.50 / 14.00 11.50 / 14.00 Hr.) Sound Power Rating [dB(A)] (b) 73.1 73.1 PERFORMANCE HEATING(c) Input BTUH-1st Stage (Natural Gas) (d) 90000 115000 AFUE 81 81 Temp. Rise - Min/Max 30 / 60 30/ 60 (OF) Orifice Qty/Drill Sz. 3 / #37 3 / #33 (Natural Gas) POWER CONN. - V/ 208-230/1/60 208-230/1/60 Ph/Hz Min. Brch. Cir. Ampacity (e) 39.1 39.1 Fuse Size - Max. (amps) 60 60 Fuse Size - Recmd. (amps) 60 60 COMPRESSOR SCROLL SCROLL VOLTS/PH/HZ 208-230/1/60 208-230/1/60 R.L. Amps - L.R. Amps 24.4 / 144.2 24.4 / 144.2 OUTDOOR COIL - SPINE -FIN SPINE -FIN TYPE Rows/F. P.I 2 / 24 2 / 24 Face Area (sq. ft.) 22.99 22.99 Tube Size (in.) 3/8 3/8 INDOOR COIL - PLATE FIN PLATE FIN TYPE Rows/F. P.I 4/ 15 4 / 15 Face Area (sq. ft.) 5.0 5.0 Tube Size (in.) 3/8 3/8 Refrigeration Control EXPANSION VALVE EXPANSION VALVE Drain Conn. Size (in.) 3/4 FEMALE NPT 3/4 FEMALE NPT OUTDOOR FAN - SWEPT SWEPT TYPE DIA.(IN.) 28.25 28.25 DRIVE/NO. SPEEDS DIRECT/ 1 DIRECT/ 1 CFM @ 0.0 in. w.g. (f) 4800 4800 Motor- HP/R.P.M 1/3/ 825 1/3/ 825 Volts/Ph/Hz '^ 60 208-230 / 1/60 F.L. Amps/L.R Amps 1.7/3.5 1.7/3.5 INDOOR FAN -TYPE I CONSTANT TORQUEECM CONSTANT TORQUEECM Dia. x Width (in.) 11.87 X 10.68 11.87 X 10.68 Drive/No. Speeds DIRECT/ 3 DIRECT/ 3 CFM @ 0.0 in. w.g. (9) SEE FAN PERF TABLE SEE FAN PERF TABLE Motor - HP/R.P.M. 1 / 1050 1 / 1050 Volts/Ph/Hz 208-230/1/60 208-230/1/60 F.L. Amps 6.9 6.9 COMBUSTION FAN - TYPE CENTRIFUGAL CENTRIFUGAL Drive/No. Speeds DIRECT/ 1 DIRECT/ 1 Motor - HP/R.P.M. 1/34 / 3075 1/34 / 3055 Volts/Ph/Hz 230/1/60 230/1/60 FLA .24 .25 FILTER / FURNISHED NO NO Type Recommended THROWAWAY THROWAWAY Recmd. Face Area (sq. ft) (h) 5 .3 5.3 REFRIGERANT R-410 R-410 Charge (lbs.) 9.65 9.65 CHARGING SPECIFICATIONS Subcooling 110 11° GAS PIPE SIZE (in.) 1/2 1/2 DIMENSIONS HXDXW HXDXW Crated (in.) 50 X 47 X 62 50 X 47 X 62 WEIGHT Shipping (lbs.) / Net (lbs.) 580 / 476 586 / 482 (a) Rated in accordance with AHRI Standard 210/240. AHRI standard rating conditions are: 80 D.B.67 W.B. entering air to indoor coil. 95 D. B. entering air to outdoor coil. (b) Sound Power values are not adjusted for AHRI 270-95 tonal corrections. (c) Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. (d) Convertible to LPG. (e) This value is approximate. For more precise value, see Unit Nameplate. M Standard Air - Dry Coil - Outdoor. (e) Based on U.S. Government Standard Tests. (h) Filters must be installed in return airstream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.051, W.C. 4YCC4060A-SUB-1 F-EN Outline Drawings 7. 78 [II/161 SECTION TYPICAL (8) SIDES OF SIDEFLOW DUCT OPENINGS 18. O3 18.29 123/32] [23132] 4. 22 19/I61 SECTION Y-Y TYPICAL (8) SIDES OF DOWNFLOW DUCT OPENINGS S Figure 1. 4YCC4042-4060 19.0 [3/EI FEMALE NPT RECOMMENDED SERVICE CLEARANCE MMIIN. FRONT SIDE Note: The view labeled "Bottom Side" represents the base as viewed looking up from underneath the unit. BOTTOM SIDE 4YCC4060A-SUB-1 F-E N FRONT SIDE Note: The view labeled "Bottom Side" represents the base as viewed looking up from underneath the unit. BOTTOM SIDE 4YCC4060A-SUB-1 F-E N Outline Drawings Figure 2. 4YCC4042-4060 372.82 0 lull [14-II/16] (OUTSIDE) lid f 449.02 r [17-II/I6] 79.50 (OUTSIDE) [3-1/8) 449 02 176.07 [17-II/I6] [6-15/I6] (OUTSIDE) BACK DUCT OPENINGS 0 /8] 1402.34 (55-7/32] (SURFACE AREA) BACK SIDE Model Height mm/in Approx. Corner Weight - kg / Ibs Shipping Weight kg/Ibs Total Unit Weight kg/Ibs Center of Gravity mm/in A W1 W2 W3 W4 B C 4YCC4042 (060) 898.53 [35-3/8] 71.2 [157] 46.6 [103] 34.6 [76] 53.1 [117] 252.2 [555] 202.0 [452] 470.0 [18.5] 731.0 [28.8] 4YCC4042 (090) 898.53 [35-3/8] 71.8 [158] 47.2 [104] 35.2 [78] 53.6 [118] 254.5 [561] 207.3 [457] 470.0 [18.5] 731.0 [28.8] 4YCC4048 (070) 1000.13 [39-3/8] 71.4 [157] 44.6 [98] 33.2 [73] 53.9 [119] 250.3 [552] 202.1 [448] 433.0 [17.0] 743.3 [29.3] 4YCC4048 (090) 1000.13 [39-3/8] 72.0 [159] 45.0 [99] 33.8 [75] 54.4 [120] 252.6 [557] 205.4 [453] 433.0 [17.0] 743.3 [29.3] 4YCC4060 (090) 1000.13 [39-3/8] 77.1 [170] 45.8 [101] 1 34.4 [76] 58.3 [128] 263.1 [580] 215.9 [476] 433.0 [17.0] 743.3 [29.3] 4YCC4060 (115) 1000.13 [39-3/8] 78.0 [172] 46.3 [102] 34.9 [77] 59.0 [130] 265.8 [586] 218.6 [482] 414.0 [16.3] 635.0 [25.0] 4YCC406OA-SUB-1 F-EN 5 Outline Drawings Figure 3. 4YCC4042-4060 457.20 1181 (INSIDE) 75.41 [2-31/32 [151VV (INSIDE) BOTTOM DUCT OPENINGS 24V ENTRY �o 359.80 294.02 [14-5/321 111-9/161 178.66 1 1 [1-1/321 84.96 GAS LINE ENTRY [3 II/32] I FOR 12.70 [1121 N.P.T. GAS CONNECTION 98.66 [3-7/81 POWER ENTRY 27.78 DIA. HOLE [1-3/321 127.84 RIGHT SIDE [5-1/321 381.00 [151 (INSIDE) 75 9/161 20 >IDE) 09 /81 6 4YCC4060A-SUB-1 F-E N Indoor Fan Performance Table 1. Horizontal Airflow EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED Number 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 CONSTANT CIRCULATION 1 CFM APPROXIMATELY 40 50 % COOLING OR HEATING AIRFLOW WATTS CFM 1857 1831 1800 1766 1737 1692 1655 1617 — — — COOLING -LOW 2 WATTS 515 523 533 544 554 569 582 595 CFM 2083 2058 2032 2003 1974 1943 1911 1877 1843 1807 — COOLING -HIGH 3 WATTS 749 759 769 779 788 803 816 830 845 860 — CFM 1534 1489 1445 1403 1361 1314 1275 1234 — — — HEAT -LOW 4 WATTS 281 292 304 314 325 337 348 358 — — — CFM — 1594 1551 1511 1471 1430 1386 1344 1305 1265 — HEAT -HIGH 5 WATTS — 348 361 373 384 396 409 420 432 443 — 4YCC4060A1115A EXTERNAL STATIC PRESSURE (IN. WG) CONSTANT CIRCULATION 1 CFM APPROXIMATELY 40 50 % COOLING OR HEATING AIRFLOW WATTS CFM 1857 1831 1800 1766 1737 1692 1655 1617 — — — COOLING -LOW 2 WATTS 515 523 533 544 554 569 582 595 — — — CFM 2083 2058 2032 2003 1974 1943 1911 1877 1843 1807 — COOLING -HIGH 3 WATTS 749 759 769 779 788 803 816 830 845 860 — CFM 1827 1792 1757 1721 1685 1646 1605 1570 — — — HEAT -LOW 4 WATTS 492 505 517 529 541 553 566 577 — — — CFM — 1927 1894 1861 1824 1788 1750 1711 1674 1639 — HEAT -HIGH 5 WATTS — 614 627 639 651 664 677 689 702 715 Table 2. Down Airflow EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED Tap 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Number CONSTANT CFM CIRCULATION 1 APPROXIMATELY 40 - 50 % COOLING OR HEATING AIRFLOW WATTS CFM 1857 1831 1800 1766 1737 1692 1655 1617 — — — COOLING -LOW 2 WATTS 515 523 533 544 554 569 582 595 — — — CFM 2083 2058 2032 2003 1974 1943 1911 1877 1843 1807 — COOLING -HIGH 3 WATTS 749 759 769 779 788 803 816 830 845 860 — CFM 1541 1497 1452 1410 1367 1321 1281 1240 — — — HEAT -LOW 4 WATTS 282 293 305 316 327 339 349 360 — — — CFM — 1602 1558 1518 1478 1437 1392 1351 1311 1271 — HEAT -HIGH 5 WATTS — 350 363 374 386 398 411 423 434 445 — 4YCC4060A1115A EXTERNAL STATIC PRESSURE (IN. WG) 4YCC4060A-SUB-1 F-EN Indoor Fan Performance Table 2. Down Airflow (continued) CONSTANT CIRCULATION 1 CFM APPROXIMATELY 40 50 % COOLING OR HEATING AIRFLOW WATTS CFM 1857 1831 1800 1766 1737 1692 1655 1617 - - - COOLING -LOW 2 WATTS 515 523 533 544 554 569 582 595 - - - CFM 2083 2058 2032 2003 1974 1943 1911 1877 1843 1807 - COOLING -HIGH 3 WATTS 749 759 769 779 788 803 816 830 845 860 - CFM 1815 1790 1757 1712 1679 1648 1613 1574 HEAT -LOW 4 WATTS 510 520 532 549 560 570 582 596 - - - CFM - 1910 1875 1839 1803 1773 1736 1704 1661 1622 - HEAT -HIGH 5 WATTS - 630 634 647 660 672 685 698 712 726 - 4YCC4060A-SUB-1 F-E N Full Perimeter Roof Mounting Curb CHANNEL END -- r i i i i Figure 4. 3.5 — 5.0 Ton Models BAYCURB051A Full Perimeter Roof Mounting Curb 10 7/8 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer \ is not responsible for the unauthorized use of these \ drawings and expressly disclaims any liability for damages resulting from such unauthorized use. C' CHANNEL SIDE OO!D NAILER SERVICE CLEARANCE DIMENSIONS A B C D WC*/TC* 42.00 36.00 12.00** 24.00 DC*/YC* 42.00 36.00 12.00** 36.00 ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 4YCC4060A-SUB-1 F-EN 9 MicroMetl Date: Weight: 92lbs (US) 41.73kg (Metric) Part Number: ECC-IMP2LCA-DYDB RTU: Submitted to: Approved by: Notes: Economizer - Economizer - Ultra Low Leak Economizer, Convertible Orientation, Belimo Zip - Single/Multiple Speed Electromechanical, Adjustable Dry Bulb Sensor, Belimo Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. Filters Are yield Supplied. Number of Filters Needed :(1)20"x18"x1"&(1)18"x18"x1"Or(1)20"x18"x2"&(1)18"x18"x2" Filter Rack T amca Field Supplied Filter WORLDWIDE CERTICIEP Barometric Relief Hood RIA Damper AIR EAHA4[ AIR rrlvoxr.Ano[ Hinged OfAAssembly MicroMetl Corporation NOTES: certifies that the models GRII and NS11 shown 1. Filter Racks Supplied With Economizer. herein are licensed to Dear - Filters Are Field Supplied the AMCASea I. 2. For Heat Pump Applications A Field Supplied And Installed The ratings shown are It ased on tests and 24Vac - Spst Normally Open Relay Will Be Needed. a procedures performed in MicroMetl Part Numbers: accordance with AMCA (1) Relay - 9901-5030 Publication 511 and with (4) Wire Leads- 9901-0134 of heIAMCACertiFedents "ALLOW FOR 361N. OF CLEARANCE" Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. VERTICAL ORIENTATION HORIZONTAL ORIENTATION _ � a 21491' 21.250' 17.537" This Document Is The Property Of MicroMetl Corporation And Is Delivered Upon The Express Condition That The Contents Will Not Be Disclosed Or Used Without MicroMetl's Written Consent. Master Revision 0001 A page Revision 0001 A MicroMetl Reserves The Right To Discontinue, Or Change At Any Time, Specifications & Designs Without Any Notice Incurring Obligations. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC -- Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC -- Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 Date: Weight: 92lbs (US) 41.73kg (Metric) Part Number: ECC-IMP2LCA-DYDB MicroMetl RTU: Submitted to: Approved by: Notes: Economizer - Economizer - Ultra Low Leak Economizer, Convertible Orientation, Belimo Zip - Single/Multiple Speed Electromechanical, Adjustable Dry Bulb Sensor, Belimo Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. Filters Are Held Supplied. Number of Filters Needed : (1) 20" x 18" x 1 " & (1) 18" x 18" x 1 " Or (1) 20" x 18" x 2" & (1) 18" x 18" x 2" Compliant Economizer: 1. Title 24: Economizers meet California Energy Commission Title 24-201312016 prescriptive section 140.4 (damper leakage etc.), and mandatory section 120.2.i for Fault Detection and Diagnostic controls (Zip Economizer BZE1245). 2. ASHRAE 90.1: Economizers meetASHRAE 90.1-201312016 damper leakage requirements, and meet 2016 Fault Detection and Diagnosis requirements_ 3. IECC: Economizers meet IECC 2012; IECC 2015, and IECC 201 B for outside air, return air, and relief damper (when provided) leakage requirements, and IECC 2015 and IECC 2018 for Fault Detection and Diagnostic requirements. Note: IECC 2015 and IECC 2018 requires differential return air sensor, which must be ordered separately. 4. AMCA: Outside air and return air (volume) dampers are AMCA Class 1A rated at 1" w.g. Refer to MicroMetl NS1 catalog sheet on web site for details. Relief air dampers (when provided) are also AMCA rated_ Refer to GR1 series catalog sheet on web site for details. IFeatu res: • Gear driven design for trouble -free operation, eliminating slippage and binding associated with standard linkage. • Includes assembled rainhood with aluminum water entrainment filters in the outside air section. PVRIR - Rainhood is sloped for water run-off. unuu - Power exhaust options available_ - Logic wiring is field supplied and installed between the commercial 2 stage thermostat and HVAC low voltage terminal board_ MicroMetl Corporation certifies that the models GR1 and NS1 shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. This Document Is The Property Of MicroMetl Corporation And Is Delivered Upon The Express Condition That The Contents Will Not Be Disclosed Or Used Without MicroMetl's Written Consent. Master Revision 0001 A page Revision 0001 A MicroMetl Reserves The Right To Discontinue, Or Change At Any Time, Specifications & Designs Without Any Notice Incurring Obligations. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC -- Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC -- Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 Mechanical Specifications General The units shall be horizontal airflow as shipped and convertible to downflow. All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. Units shall be certified to UL Standard 1995. Units shall be designed to operate at ambient temperatures as high as 115°F. Cooling performance shall be rated in accordance with AHRI standards. The YC heating/cooling unit design is certified to ANSI 221.47/CSA 2.3, specifically for outdoor applications using natural gas or propane. All units shall be designed for outdoor rooftop or ground level installation. Unit Casing All components shall be mounted in a weather - resistant steel cabinet with an enamel finish. Access panels shall be provided for unit controls and indoor coil and fans. Indoor air section compartment shall be completely insulated with fireproof, permanent, odorless fiber material. Knockouts shall be provided for utility and control connections. Drain connections shall be provided to accommodate indoor water runoff. Compressor The compressor shall be hermetically sealed, high efficiency scroll compressors. Internal overcurrent and over temperature protection, internal pressure relief shall be standard. Other features include centrifugal oil pump, low vibration and noise. Refrigeration System All units shall have refrigerant control. Service pressure tap ports and a refrigerant line filter shall be standard. Evaporator Coil (5 Ton Model) Internally enhanced 3/ 8" OD seamless copper tubing mechanically bonded to aluminum fins, factory pressure and leak tested at 480 — 650 psig. All units have TXV to control refrigerant flow. Condenser Coil The Spine Fin T"I condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8" OD seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2.000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan Constant Torgue, forward -curved, centrifugal wheel in a Composite Vortica ® Blower housing. Motor shall have thermal overload protection and permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Outdoor Fan One direct -drive, statically and dynamically balanced propeller fan shall be used in a draw -through vertical discharge configuration. Permanently lubricated weather proof motor shall have built-in thermal overload protection. System Controls System controls include condenser fan, evaporator fan and compressor contactors. Accessories Roof Curb The roof curb shall be designed to mate with the unit and provide support and complete weathertight installation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal between supply and return openings of the curb and unit. The roof curb design allows field fabricated ductwork to be connected directly to the curb. Curb ships knocked down for field assembly, and includes factory installed wood nailer strips. Heating System Gas -Fired Heating Section Models shall provide completely assembled, wired and piped gas fired heating systems within unit. Design certified by UL, specifically for outdoor application. Threaded gas connection on the unit. Electric Ignition System Main burner is lit each time thermostat calls for heat. Flame sensor proves flame and keeps the main burner on. Should a loss of flame occur, the main valve closes and the spark recurs within 0.8 seconds. When thermostat is satisfied, main burner is extinquished. Forced Combustion Blower Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility. Heat Exchanger Stainless steel tubes. Free floating design. Burners Stainless steel. Multi -port inshot. 4YCC4060A-SUB-1 F-EN 13 Mechanical Specifications Single Source Power Entry This accessory when used with electric heat accessory shall allow single source power connection to unit and heater combination. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut -to -length interconnecting wiring, and junction box (if required) to provide power sources with fuse protection as required for both the unit and accessory heater. Kit components shall install within the heater cabinet in the heater access section. Single source branch power circuit shall be protected and wired in accordance with local codes. Fully Modulating Economizer This accessory shall be field installed and be composed of the following items: 0-100 % fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage pigtails for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometric relief damper shall be standard with the economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment "off" cycle. Economizer requires BAYRLAY004A relay kit to interface the economizer to the heat pump. Manual Outside Air Dampers Rain hood and screen shall be field installed. Suitable for up to 25% outside air. Start Kit Extra compressor starting capacity for single phase equipment. Control Options Standard Indoor Thermostats Two stage heating/cooling or one stage heating/ cooling thermostats shall be available in either manual or automatic changeover. Programmable Electronic Night Setting Thermostat Programmable electronic thermostat shall provide heating setback and cooling setup with 7—day programming capability. 1 H/1C or 2H/2C models available. 14 4YCC4060A-SUB-1 F-E N About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com. 0%.-s Intertek The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to aIn rid irectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4YCC4060A-SUB-1F-EN of Jun2020 Supersedes 4YCC4060A-SUB-1E-EN (June2019) ©2020