APPROVED BLD BLD2022-0928+PLANS+7.13.2022_3.07 (2)RECEIVED
Jul 14 2022
E x i s t i n /Pro o s e d: Scale 1 /4" 1' CITY PA T MONDS
DEVELOPMENT SERVICES
_ DEPARTMENT
r--------------------
I ALL REPAIRS TO FIRE RATED ASSEMBLIES
Vestibule , SHALL MAINTAIN THE RATING WITH '
MATCHING CONSTRUCTION
I--------------------'
Description of existing space:
-Flood cuts up 24" throughout entry
from sewer backup (highlighted in pink)
-Existing tile floor to remain
Description of proposed:
-Drywall and paint
-New baseboard
Main Entr
Existing the
r-- — - — - — - — - — - — - — - — - — - — -
GAEGdRY_CDMM6N_REP I INSULATION REMOVED FROM EXTERIOR WALL � S/lr,zoaz
CAVITIES AS PART OF THE REPAIR TO BE
I REPLACED WITH MINIMUM R-15 IN EXTERIOR
2X4 WALLS AND R-21 IN EXTERIOR 2X6 WALLS.
L__---------------------
City Of Edmonds
Building Department
Work WATER DAMAGE REPAIR
-------------- -------------
Address ; 505 5TH AVE S COMMON AREAS & GARAGE
-----------------------------------------------------------------
----------------------------------------------------------------
Owner THE GREGORY
Approved Date
Building Official
Permit Number
08/04/2022
lr&4pl t
OBTAIN ELECTRICAL
PERMIT FROM
STATE LABOR &
INDUSTRIES
Vestibule
Pagc: 51
1y WIDOW;]
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
RECEIVED
Existing/Proposed: Scale 1/8"=J'
Description of existing space:
-Flood cuts up 24" throughout entire hallway
from sewer backup (highlighted in pink)
-All carpeting removed throughout the hallway
Description of proposed:
-Drywall, insulation, and paint on affected walls
-New carpet to be installed
-New baseboard/casing to be installed
�V 1•
jj
New Carpet
I
Jul 14 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
'I _u,-
New Carpet
_. ,a-
_ Hall 1 _ _
- i tl
III- �q-s
E111.Ix �' -� l
r
1
-------------------
I ALL REPAIRS TO FIRE RATED ASSEMBLIES
SHALL MAINTAIN THE RATING WITH
MATCHING CONSTRUCTION
I--------------------'
r-------------------W---
I INSULATION REMOVED FROM EXTERIOR ALL
CAVITIES AS PART OF THE REPAIR TO BE
I REPLACED WITH MINIMUM R-15 IN EXTERIOR I
2X4 WALLS AND R-21 IN EXTERIOR 2X6 WALLS.
---------------------
4
Hallways
RECEIVED
Existing/Proposed: Scale 1/41111=111
Stairs]
r
Description of existing space: New Carpet _
Ent" -6
- 7 v
-Flood cuts up 24" throughout entries to stairs from sewer backup
(highlighted in pink)
-All carpeting/pad removed from entries _
and stairs stair G.1
i~
Description of proposed: -
-Drywall, insulation, and paint 1
-New carpet throughout entries and = h New Carpet
stairways
-New baseboard/casing to be installed
Jul 14 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
New Carpet
r- - - - - - - - - - - - - - - - - - - -
ALL REPAIRS TO FIRE RATED ASSEMBLIES
SHALL MAINTAIN THE RATING WITH
MATCHING CONSTRUCTION
--------------------'
r----------------------
i INSULATION REMOVED FROM EXTERIOR WALL
CAVITIES AS PART OF THE REPAIR TO BE
I REPLACED WITH MINIMUM R-15 IN EXTERIOR
2X4 WALLS AND R-21 IN EXTERIOR 2X6 WALLS.
L---------------------
a
4
Stairs 1
GREGORY_COMMON _REP 511612D22 Page:53
RECEIVED
Existing/Proposed: Scale 1/4"=1'
StairQ
Description of existing space:
-Flood cuts up 24" throughout entries
to stairs from sewer backup
-All carpeting/pad removed from entries
and stairs (highlighted in pink)
Description of proposed:
-Drywall, insulation, and paint
-New carpet/pad throughout entries and
stairways
-New baseboard/casing to be installed
1 Or 4"
New carpet
V4—Y
T
T
-4'9"
�5F 4'!!
' kr-
ew car et
15,
Jul 14 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Entry-1
New Car
T
ri
r- - - - - - - - - - - - - - - - - - - -
I ALL REPAIRS TO FIRE RATED ASSEMBLIES
SHALL MAINTAIN THE RATING WITH
MATCHING CONSTRUCTION
I--------------------'
r----------------------
i INSULATION REMOVED FROM EXTERIOR WALL
CAVITIES AS PART OF THE REPAIR TO BE
I REPLACED WITH MINIMUM R-15 IN EXTERIOR
2X4 WALLS AND R-21 IN EXTERIOR 2X6 WALLS. j
`---------------------
i4, 11,,E
I 10' III
�.a
tic's
GRE RY_COMMON—REP 5/16/2022 Pagc.54
Existing/Proposed: Scale 1/411111=1111
Rcstrooms
I
Description of existing space:
-Flood cuts up 24" in pink
highlighted spaces
from sewer backup
-Carpet/pad removed in
hallway and in storage Q
-Tile to remain in bathrooms
and concrete to remain in
janitor closet
l9' S"
RECEIVED
Jul 14 2022
CITY OF EDMONDS r
DEVELOPMENT SERVICES I ALL REPAIRS TO FIRE RATED ASSEMBLIES
DEPARTMENT SHALL MAINTAIN THE RATING WITH
MATCHING CONSTRUCTION
I--------------------'
r----------------------
I INSULATION REMOVED FROM EXTERIOR WALL
CAVITIES AS PART OF THE REPAIR TO BE
I REPLACED WITH MINIMUM R-15 IN EXTERIOR I
2X4 WALLS AND R-21 IN EXTERIOR 2X6 WALLS. j
---------------------
+ 913„
L
' T„
Janitor Closet
r
Hall
New
v Carpet
l9' 6" + —54 2"
Description of proposed:
-Drywall, insulation, and paint at affected walls (pink)
-New carpet/pad to be put in hallway and storage Q
-New baseboard/casing GREGORY_COMMON—REP
to be installed
Storage Q
New
Carpet
Existing concrete to remain
M
estroorns
5/ 16/2022 Pagc: 55