Loading...
APPROVED BLD BLD2022-1450+Plumbing_Plan+10.21.2022_9.24.14_AM+3177850ABBREVIATIONS PLUMBING SYMBOL LEGEND PLUMBING LINETYPE LEGEND EQUIPMENT TAGS AC AIR CONDITION (-ING, -ED) INV INVERT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - DOMESTIC COLD WATER ACCU AIR COOLED CONDENSING UNIT GWH GAS WATER HEATER AFF ABOVE FINISHED FLOOR KW KILOWATT ----------------------------- DOMESTIC COLD WATER (BELOW FLOOR/GRADE) AHU AIR HANDLING UNIT HU HUMIDIFIER AMP AMPERE (AMP, AMPS) LAT LEAVING AIR TEMPERATURE ® FLOOR DRAIN X ANCHOR a REDUCER DOMESTIC COLD WATER (EXISTING) AHUP AIR HANDLING UNIT PUMP HUH HORIZONTAL UNIT HEATER AP ACCESS PANEL LBS POUNDS - DOMESTIC HOT WATER BP BOOSTER PUMP HWP HEATING WATER PUMP -------------------------------- - CDWP CONDENSER WATER PUMP IH INTAKE HOOD BTU BRITISH THERMAL UNIT LWB LEAVING WET BULB FLOOR SINK DOMESTIC HOT WATER (EXISTING) CEF CEILING EXHAUST FAN MAU MAKE-UP AIR UNIT CBV CIRCUIT BALANCING VALVE LWT LEAVING WATER TEMPERATURE lid PIPE FLANGE 0- FLOW ARROW CFH CUBIC FEET PER HOUR MA MIXED AIR W/HALF GRATE G GAS CHWP CHILLED WATER PUMP PCWP PRIMARY CHILLED WATER PUMP CFM CUBIC FEET PER MINUTE MAX MAXIMUM ------------------ G------------------ GAS (ON ROOF) CP CIRCULATING PUMP PHWP PRIMARY HEATING WATER PUMP CHW CIRCULATING HOT WATER MBH THOUSAND BTU'S/HR FLOOR SINK PIPE GUIDE STEAM TRAP F&T G GAS (EXISTING) CPR CONDENSATE PUMP AND RECEIVER PRV POWER ROOF VENTILATOR CHWR CHILLED WATER RETURN MIN MINIMUM ® W/FULL GRATE ( ) ) CRP CONDENSATE RETURN PUMP REF RELIEF EXHAUST FAN CHWR CHILLED WATER SUPPLY MISC MISCELLANEOUS G GAS (EXISTING ON ROOF) CUH CABINET UNIT HEATER RF RETURN FAN NOT APPLICABLE SANITARY SEWER (ABOVE FLOOR/GRADE) DHC DUCT HEATING COIL RH RELIEF HOOD CLG CEILING NA MI �] BALL VALVE Q AIR CHAMBER , r THERMOSTAT WELL SANITARY SEWER (BELOW FLOOR/GRADE) ECH ELECTRIC CABINET HEATER RTU ROOFTOP UNIT CO CLEANOUT NC NOISE CRITERIA EF EXHAUST FAN SCWP SECONDARY CHILLED WATER PUMP CR CONDENSATE RETURN NIC NOT IN CONTRACT SANITARY SEWER (EXISTING) EHC ELECTRIC HEATING COIL SEP SEWAGE EJECTOR PUMP CW COLD WATER NTS NOT TO SCALE WATER HAMMER -------------------------------------- VENT ES ELECTRONIC SENSOR SHWP SECONDARY HEATING WATER PUMP DB DECIBEL OA OUTSIDE AIR X GATE VALVE * ARRESTER o EXPANSION JOINT -------------------------------------- VENT (UNDERFLOOR/GRADE) EUH ELECTRIC UNIT HEATER SP SUMP PUMP DEMO DEMOLITION OBD OPPOSED BLADE DAMPER VENT (EXISTING) EWC ELECTRIC WATER COOLER TF TRANSFER FAN DIA DIAMETER ORD OVERFLOW ROOF DRAIN _ EWH ELECTRIC WATER HEATER USF UTILITY SET FAN DIFF DIFFUSER PH PHASE (ELECTRICAL) CHECK VALVE FLEXIBLE CONNECTOR WALL HYDRANT/ FCU FAN COIL UNIT VAV VARIABLE AIR VOLUME BOX 1�I � DWG DRAWING PVC POLYVINYL CHLORIDE HOSE BIBB FPB FAN POWERED VARIABLE AIR VOLUME BOX VUH VERTICAL UNIT HEATER DX DIRECT EXPANSION RA RETURN AIR MISC. SYMBOL LEGEND WS WATER SOFTENER EAT ENTERING AIR TEMPERATURE RD ROOF DRAIN ELEC ELECTRICAL REC RECESSED jai DRAIN VALVE EXPANSION TANK T TEST PLUG REL RELIEF 0 SPRINKLER HEAD (SEMI -RECESSED) ELEV ELEVATION ® EQUIPMENT TAG � CONNECTION TO EXISTING RH RELATIVE HUMIDITY EMS ENERGY MANAGEMENT SYSTEM RM ROOM �Q� STEAM TRAP ESP EXTERNAL STATIC PRESSURE RPM REVOLUTIONS PER MINUTE 2-WAY VALVE 0 WATER METER (THERMOSTATIC) O SPRINKLER HEAD (UPRIGHT) EWB ENTERING WET BULB EWT ENTERING WATER TEMPERATURE SA SUPPLY AIR A REVISION TRIANGLE < KEY NOTE O SPRINKLER HEAD FULLY RECESSED SAN SANITARY s ( ) EXH EXHAUST SD SMOKE DAMPER � SOLENOID VALVE a FLOW METER 4 VACUUM RELIEF VALVE EXIST EXISTING F COMBINATION SHEET INDEX SF SQUARE FEET FSD COMBIN FIRE/SMOKE DAMPER SP STATIC PRESSURE M 4 ALL WORK SUBJECT FCO FLOOR CLEANOUT SPEC SPECIFICATION � MOTORIZED VALVE � THERMOMETER AQUASTAT FD FIRE DAMPER ST STORM FD FLOOR DRAIN STD STANDARD EMERGENCY GAS PO.0 MECHANICAL TITLE SHEET AND SPECIFICATIONS FDC FIRE DEPARTMENT CONNECTION TD TEMPERATURE DIFFERENCE PRESSURE GAGE PRESSURE REGULATOR TO FIELD FIFE FINISHED FLOOR ELEVATION TSP TOTAL STATIC PRESSURE SHUT-OFF VALVE P1.0 PLUMBING PLAN FLR FLOOR TYP TYPICAL FPM FEET PER MINUTE V VOLTS THERMOSTATIC/PRESSURE FT FOOT OR FEET VFD VARIABLE FREQUENCY DRIVE BALANCE MIXING VALVE STRAINER PIPE DOWN GA GAGE OR GAUGE VSD VARIABLE SPEED DRIVE INSPECTION FOR GAL GALLONS VOL VOLUME GC GENERAL CONTRACTOR VTR VENT THROUGH ROOF FI TP TRAP PRIMING VALVE PUMP o PIPE UP GPH GALLONS PER HOUR W WATTS CODE CO M P LIAN C E HP HORSEPOWER W/ WITH HT HEIGHT W/0 WITHOUT 2�_ PRESSURE RELIEF VALVE P# PLUMBING FIXTURE TAG TEE DOWN HVAC HEATING, VENTILATING, AIR CONDITIONING WC WATER CLOSET HW HOT WATER WCO WALL CLEANOUT HZ HERTZ WT WEIGHT ID INSIDE DIAMETER 11 BUTTERFLY VALVE F# FLOOR RECEPTOR TAG III UNION X GLOBE VALVE Fs FLOW SWITCH rl PIPE CAP b CIRCUIT BALANCING 3-WAY VALVE S PIPE BREAK VALVE 0 PLUG VALVE >qM BACKFLOW PREVENTER APPROVED M E C H A N I C A L S P E C I F I C A T 1 0 N S 15000 GENERAL PROVISIONS 0.01 DEFINITIONS: THE TERMS LISTED BELOW ARE DEFINED AS FOLLOWS WHEN USED IN DIVISION 15 WORK AND ONLY DIVISION 15 WORK. A. WORK: LABOR AND MATERIALS OF THE CONTRACTOR AND/OR SUBCONTRACTOR. B. FURNISH: OBTAIN, COORDINATE, SUBMIT THE NECESSARY DRAWINGS, DELIVER TO THE JOBSITE IN NEW CONDITION AND GUARANTEE. C. INSTALL: RECEIVE AT THE JOB -SITE, UNLOAD, STORE, SET IN PLACE, CONNECT, PLACE IN OPERATION AND GUARANTEE. D. PROVIDE: FURNISH AND INSTALL. E. CONNECT: BRING SERVICE TO THE EQUIPMENT AND MAKE FINAL ATTACHMENTS INCLUDING NECESSARY PIPE FITTINGS, DUCTWORK, TRANSITIONS, ETC. F. CONCEALED: HIDDEN FROM SIGHT IN CHASES, FURRED SPACES, SHAFTS, ABOVE CEILING, EMBEDDED IN CONSTRUCTION, IN CRAWL SPACES OR BURIED. G. EXPOSED: NOT INSTALLED UNDERGROUND OR CONCEALED AS DEFINED ABOVE. H. REMOVE: REMOVE ALL EQUIPMENT AND MATERIALS NOT BEING RE -USED. DISPOSE OF OFF -SITE IN A LEGAL AND ENVIRONMENTALLY CONCIOUS MANNER. 0.02 PERFORMANCE: MECHANICAL CONTRACTOR SHALL PERFORM ALL WORK SPECIFIED, INDICATED AND REQUIRED UNLESS OTHERWISE NOTED, INCLUDING FINAL CONNECTIONS, IN A WORKMANLIKE MANNER USING WORKERS SKILLED AND EXPERIENCED IN THE TRADE. 0.03 SITE EXAMINATION: EXAMINE SITE BEFORE BIDDING. CLAIM NO EXTRAS RESULTING FROM LACK OF KNOWLEDGE OF SITE CONDITIONS. IF SITE CONDITIONS REQUIRE MODIFICATION OF THE SYSTEMS INDICATED IN THESE DOCUMENTS, SO ADVISE ENGINEER, AND IF ACCEPTED BY ENGINEER, INCLUDE COST OF SUCH MODIFICATIONS IN BID. 0.04 JOBSITE CONDITIONS: ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 0.05 FULL FUNCTION: PROVIDE ALL MINOR ITEMS NECESSARY FOR A COMPLETE AND FULLY FUNCTIONAL INSTALLATION. 0.06 ADMINISTRATION: PROVIDE EVIDENCE OF LICENSING, BONDING, AND INSURANCE, AND PERFORM OTHER ADMINISTRATIVE FUNCTIONS, AS REQUIRED. 0.07 PERMITS: PROCURE AND PAY FOR ALL REQUIRED PERMITS AND SERVICE CHARGES. 0.08 UTILITY SERVICES: ARRANGE FOR ALL REQUIRED UTILITY SERVICES AND PAY ALL UTILITY SERVICE FEES. 0.09 COORDINATION: CONFORM TO GENERAL CONSTRUCTION CONTRACT DOCUMENTS EXCEPT AS MODIFIED HEREIN. REFER ALSO TO STRUCTURAL AND ELECTRICAL CONTRACT DOCUMENTS. COORDINATE ALL WORK WITH OTHER TRADES. 0.10 CUTTING AND PATCHING: CUT AND PATCH AS REQUIRED. CUT OR WELD STRUCTURAL MEMBERS ONLY WITH APPROVAL OF STRUCTURAL ENGINEER. PATCHING SUBJECT TO APPROVAL BY ARCHITECT. 0.11 EXISTING FLOORS: TRENCH OR CORE BORE EXISTING FLOORS PER LANDLORD REQUIREMENTS. 0.12 ROOF PENETRATIONS: ALL ROOFING WORK SHALL BE PERFORMED BY LANDLORD -APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S COST. COORDINATE WITH LANDLORD. 0.13 EQUIPMENT SUBSTITUTIONS: REIMBURSE ELECTRICAL CONTRACTOR, AT NO CHARGE TO TENANT, FOR HIS COSTS INCURRED DUE TO SUBSTITUTION OF MECHANICAL EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING FROM THOSE INDICATED. 0.14 ADJUSTMENTS: MAKE MINOR ADJUSTMENTS TO WORK WHERE REQUESTED BY TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 0.15 REFERENCE STANDARDS: COMPLY WITH APPLICABLE STANDARDS OF NFPA, ANSI, UL, ASHRAE, AND SMACNA, EXCEPT AS SUPERSEDED BY LOCAL AUTHORITY. CONFORM WITH CONTRACT DOCUMENTS WHERE THEY EXCEED CODE MINIMUM REQUIREMENTS. 0.16 LOCAL REQUIREMENTS: COMPLY WITH THE REQUIREMENTS OF APPLICABLE CODES, LANDLORD, SERVING UTILITIES, AND THE LOCAL AUTHORITY HAVING JURISDICTION. SECURE APPROVAL OF INSTALLATION BY LANDLORD, LOCAL AUTHORITY, AND OTHERS AS REQUIRED. 0.17 MATERIALS AND EQUIPMENT: PROVIDE NEW, UL LISTED, COMMERCIAL GRADE MATERIALS, DEVICES, EQUIPMENT, AND FIXTURES, SUITABLE FOR ENVIRONMENT. REUSE EXISTING ONLY WHEN COMPLIANT WITH THE CONTRACT DOCUMENTS, IN GOOD CONDITION, AND APPROVED BY THE ENGINEER. 0.18 SHOP DRAWINGS: BEFORE ORDERING EQUIPMENT AND MATERIALS, SUBMIT NOT LESS THAN FIVE CERTIFIED COPIES OF ALL SHOP AND EQUIPMENT DRAWINGS FOR ENGINEER'S REVIEW, WHO WILL RETAIN TWO COPIES. ONLY FURNISH SYSTEMS AND EQUIPMENT IN COMPLIANCE WITH ACCEPTED SHOP DRAWINGS. 0.19 INSTALLATION: INSTALL ALL MATERIALS, EQUIPMENT AND SYSTEMS IN FULL ACCORD WITH MANUFACTURER'S INSTRUCTIONS. 0.20 LAYOUT: INSTALL ALL PIPING AND DUCTWORK TO PRESENT A NEAT AND ORDERLY APPEARANCE. RUN ALL LINES PARALLEL WITH BUILDING CONSTRUCTION. MAINTAIN HEADROOM AND EQUIPMENT CLEARANCE, AND GRADIENT WHERE REQUIRED. ALLOW FOR EXPANSION AND CONTRACTION. 0.21 ACCESS DOORS: PROVIDE ACCESS DOORS OR PANELS FOR ALL VALVES, CLEANOUTS, DAMPERS, CONTROLS, DEVICES, AND OTHER ITEMS REQUIRING INSPECTION OR MAINTENANCE. ACCESS PANELS SERVING HVAC COMPONENTS SHALL BE 12-INCHES BY 12-INCHES MINIMUM OR LARGER TO PROVIDE SUFFICIENT WORKING CLEARANCE FOR COMPONENT BEING ACCESSED. 0.22 COMMISSIONING: THOROUGHLY TEST AND DEMONSTRATE PROPER OPERATION OF ALL SYSTEMS AND EQUIPMENT FURNISHED OR INSTALLED UNDER THIS CONTRACT. 0.23 RECORD DRAWINGS: PREPARE AND SUBMIT TO GENERAL CONTRACTOR RECORD DRAWINGS SHOWING ALL SIGNIFICANT DEVIATIONS FROM CONSTRUCTION DOCUMENTS. INCLUDE MANUFACTURER AND MODEL NUMBERS FOR ALL EQUIPMENT INSTALLED. 0.24 0 & M MANUALS: AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER OR OPERATOR. THE MANUAL SHALL INCLUDE BASIC DATA RELATING TO THE OPERATION AND MAINTENANCE OF HVAC SYSTEMS AND EQUIPMENT. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. WHERE APPLICABLE, HVAC CONTROLS INFORMATION SUCH AS DIAGRAMS, SCHEMATICS, CONTROL SEQUENCE DESCRIPTIONS, AND MAINTENANCE AND CALIBRATION INFORMATION SHALL BE INCLUDED. 0.25 WARRANTY: UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF FINAL ACCEPTANCE, EXCEPT WARRANT AIR CONDITIONING COMPRESSORS FOR FIVE YEARS AND GAS -FIRED HEAT EXCHANGERS FOR 10 YEARS. DURING WARRANTY PERIOD, REPAIR OR REPLACE DEFECTIVE MATERIALS, EQUIPMENT OR WORKMANSHIP WITHOUT COST TO TENANT. 0.26 EQUIPMENT IDENTIFICATION: IDENTIFY ALL APPLICABLE ROOFTOP EQUIPMENT WITH TENANT'S NAME, SPACE NUMBER AND UNIT NUMBER, USING 2" HIGH PAINTED CHARACTERS OR STAMPED METAL TAG. LABEL INDOOR EQUIPMENT WITH UNIT NUMBER IN LIKE MANNER. 0.27 DRAWINGS ARE DIAGRAMMATIC: VERIFY ALL DIMENSIONS AND LENGTHS, AND ADJUST EQUIPMENT, PIPE AND DUCT LOCATIONS TO AVOID CONFLICTS WITH OTHER CONSTRUCTION AND TRADES. 0.28 DOCUMENT PRIORITY: DRAWING INDICATIONS AND NOTATIONS SUPERSEDE THESE SPECIFICATIONS. 0.29 RATINGS: REFER TO DRAWINGS AND SCHEDULES FOR ADDITIONAL RATINGS AND REQUIREMENTS. 0.30 PROJECT REQUIREMENTS: REFER TO DRAWINGS FOR PARTICULAR PROJECT REQUIREMENTS, AS NOT ALL ITEMS INCLUDED IN THESE SPECIFICATIONS MAY BE REQUIRED FOR THIS PROJECT. 0.31 DOCUMENT ERRORS: NOTIFY THE ENGINEER OF ANY ERRORS, DISCREPANCIES OR OMISSIONS BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAILING SUCH NOTICE, BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 15100 BASIC MATERIALS AND METHODS 1.10 PIPE HANGERS AND SUPPORTS: PROPERLY SUPPORT ALL PIPING FROM JOISTS (TOP CHORD) OR OTHER STRUCTURAL MEMBERS. FOR PIPES UP TO 4" O.D., USE GRINNELL FIG. 260 CLEVIS HANGERS WITH 3/8" ROD, OR FIG. 195 BRACKETS. 1.20 INSULATION SHIELDS: PROVIDE 18 GAUGE X 12" LONG GALVANIZED INSULATION SHIELDS AT SUPPORT POINTS FOR INSULATED PIPES. 1.30 PIPE SUPPORT SPACING: SUPPORT PIPE NOT LESS THAN 6 FT. ON CENTER FOR COPPER PIPE UP TO 2" O.D., OR NOT LESS THAN 10 FT. ON CENTER FOR STEEL PIPE UP TO 4" O.D. 1.40 COPPER CONTACT: PROVIDE COPPER PLATED HANGERS AND SUPPORTS WHERE IN CONTACT WITH COPPER PIPE. 1.50 PIPE SLEEVES: SLEEVE ALL HORIZONTAL PIPING WHICH PENETRATES WALLS WITH STANDARD WEIGHT STEEL PIPE OF 1" GREATER DIAMETER THAN PIPE OR INSULATION O.D. CUT SLEEVE FLUSH WITH WALL. FINISH BOTH SIDES. 1.60 SEALANT: SEAL PIPE SLEEVES WITH ROPE AND EXPANDO NON -SHRINK SEALANT. FIRE/SMOKE SEAL PENETRATIONS OF RATED CONSTRUCTION TO MAINTAIN RATING. 1.70 WALL PLATES: FIT UNCOVERED PIPE PASSING THROUGH WALLS WITH WALL PLATES, CRANE NO. 10 OR EQUAL. 15200 THERMAL AND ACOUSTIC INSULATION 2.10 VIBRATION ISOLATION: PROVIDE EFFECTIVE VIBRATION ISOLATION DEVICES, AND FLEXIBLE CONNECTIONS, FOR ALL MOVING MACHINERY. PROVIDE DEVICES IN ACCORDANCE WITH THE RECOMMENDATIONS IN THE ASHRAE HANDBOOK, HVAC APPLICATIONS (LATEST EDITION), CHAPTER "SOUND AND VIBRATION CONTROL". 2.20 NOISE TRANSMISSION: INSTALL PIPING AND DUCTWORK FREE FROM CONTACT WITH STRUCTURE OR EQUIPMENT TO PREVENT NOISE TRANSMISSION. 2.30 INSULATION REQUIREMENTS: INSULATE SYSTEMS AS SPECIFIED ONLY AFTER THEY HAVE BEEN TESTED AND INSPECTED. CLEAN ALL SURFACES THOROUGHLY OF MOISTURE, FOREIGN MATERIAL, GREASE, AND RUST. INSTALL INSULATION CONTINUOUS THROUGH WALL AND FLOOR PENETRATIONS. 2.31 EXISTING SYSTEMS BEING RE -USED: INSULATE EXISTING PIPE AND DUCT SYSTEMS BEING RE -USED SAME AS SPECIFIED FOR NEW SYSTEMS. REPAIR/REPLACE EXISTING INSULATION TO LIKE -NEW CONDITION AS REQUIRED. 2.32 INSULATION HAZARDS: USE ONLY INSULATION, JACKETS, ADHESIVES, SEALERS, AND COATINGS WITH FIRE HAZARD RATING NOT TO EXCEED 25/50/50 FLAME SPREAD, FUEL CONTRIBUTED, AND SMOKE DEVELOPED, IN ACCORDANCE WITH UL 723 AND ASTM E84. 2.33 INSULATED PLUMBING SYSTEMS: INSULATE HOT AND COLD WATER PIPING WITH 1" THICK CLOSED CELL, SELF SEALING FLEXIBLE TUBING, ARMAFLEX 2000 OR EQUAL. 15400 PLUMBING 4.10 DRAIN, WASTE AND VENT PIPING: A. BELOW GRADE: 1. PVC PIPE ASTM D2665, WITH PVC FITTINGS AND ASTM D2855 SOLVENT WELD JOINTS WITH ASTM D2564 SOLVENT CEMENT. 2. NO -HUB CAST IRON SANITARY SYSTEM PER CISPI 301-69T. 3. SERVICE WEIGHT CAST IRON HUB AND SPIGOT WITH NEOPRENE GASKET, PER CISPI HSN-68T. B. ABOVE GRADE: 1. NO -HUB CAST IRON SANITARY SYSTEM PER CISPI 301-69T. 2. GALVANIZED PIPE WITH CAST IRON DRAINAGE FITTINGS. 3. INDIRECT DRAINS: COPPER TUBE, ASTM B306, DWV, WITH COPPER FITTINGS AND SOLDERED JOINTS. 4.20 DOMESTIC (POTABLE) WATER SUPPLY PIPING: A. BELOW GRADE: TYPE K SOFT TEMPER COPPER TUBE, WITH NO JOINTS. B. ABOVE GRADE: TYPE L HARD TEMPER COPPER TUBE PER ASTM B88, WITH WROUGHT COPPER FITTINGS PER USASI B16.18 AND .18A. C. JOINTS: USE ONLY 95/5 LEAD-FREE SOLDER IN POTABLE WATER PIPING. PROVIDE DIELECTRIC UNIONS AT EVERY JUNCTION OF TWO DISSIMILAR METAL PIPE MATERIALS. 4.40 VALVES: FURNISH AND INSTALL VALVES WHERE INDICATED ON PLAN AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. PROVIDE VALVES RATED FOR 125 PSIG OR GREATER WORKING PRESSURE IN WATER PIPING. A. CHECK VALVE UP TO 3": CRANE NO. 37, OR EQUAL B. GLOBE VALVE UP TO 3": CRANE NO. 1, 17TF, OR EQUAL C. GATE VALVE UP TO 3": CRANE NO. 428, 1334, OR EQUAL D. BALL VALVE UP TO 3": APOLLO SERIES 70-100, 70-200, OR EQUAL E. SHOCKSTOP: WADE W-5 (HOT), WADE W-10 (COLD), OR EQUAL F. BACKFLOW PREVENTER: WATTS NO. 913D, OR EQUAL G. VACUUM RELIEF VALVE: WATTS NO. N36 - 3/4", OR EQUAL H. PRESSURE REDUCING VALVE: WATTS NO. U5 SERIES, OR EQUAL I. TRAP SEAL PRIMER: JOSAM NO. 88250 4.50 PLUMBING FIXTURES AND EQUIPMENT: FURNISH AND INSTALL PLUMBING FIXTURES AND EQUIPMENT AS SCHEDULED ON DRAWINGS, OR APPROVED EQUAL. 4.60 INSTALLATION: A. INSTALL AND SECURE FIXTURES IN PLACE WITH WALL CARRIERS AND BOLTS. PROVIDE BRACKETS, BRACES AND REINFORCING ANGLES AS REQUIRED IN ALL PARTITIONS NOT SUFFICIENT IN THEMSELVES TO SUPPORT PLUMBING FIXTURES OR OTHER WALL -HUNG EQUIPMENT. B. INSTALL EACH FIXTURE WITH CHROME PLATED, 17 GAUGE TUBING TRAP WITH CLEANOUT, EASILY REMOVABLE FOR SERVICING AND CLEANING. C. INSTALL COMPONENTS LEVEL, PLUMB AND SECURE. D. SEAL FIXTURES TO WALL AND FLOOR SURFACES WITH SEALANT, COLOR TO MATCH FIXTURE. E. ROUTE PIPING IN ORDERLY MANNER. INSTALL PIPING TO CONSERVE BUILDING SPACE AND NOT INTERFERE WITH USE OF SPACE. GROUP PIPING AT COMMON ELEVATION WHENEVER PRACTICAL. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING PIPE, JOINTS OR CONNECTED FIXTURES/EQUIPMENT. PROVIDE CLEARANCE FOR INSTALLATION OF INSULATION AND ACCESS TO VALVES AND FITTINGS. PROVIDE ACCESS WHERE VALVES AND FITTINGS ARE NOT EXPOSED. SLOPE PIPING AND ARRANGE TO DRAIN AT LOW POINTS. F. INSTALL NON -CONDUCTING DIELECTRIC CONNECTIONS WHENEVER JOINING DISSIMILAR METALS. G. PROVIDE SHUT-OFF VALVES AT ALL SUPPLY CONNECTIONS TO FIXTURES AND EQUIPMENT. H. INSULATE SUPPLY AND WASTE PIPES OF ALL HANDICAP FIXTURES. I. EXPOSED WATER PIPING SHALL BE CHROME -PLATED BRASS. 4.95 CLEANING AND TESTING: CLEAN, DISINFECT, AND TEST ALL PLUMBING AND PIPING SYSTEMS. 5.65 MISCELLANEOUS DRAIN LINES, RECEIVING COOLING COIL CONDENSATE, DRIP FOR HUMIDIFIERS, ETC.: TYPE "DWV" COPPER, WITH WROUGHT COPPER FITTINGS AND SOLDERED JOINTS. GLANS MUST BE ON JOB SITE City Of Edmonds Building Department Work PLUMBING FOR TI Address 23632 HIGHWAY 99 SUITE A Owner nFINITY Approved Date 11 /08/2022 Building Official Eric, Ga4*_r Permit Number BLD2022-14 ❑ 0 RECEIVED Oct 21 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HALLBERG ENGINEERING Mechanical/Electrical Consulting Engineers 1750 Commerce Court White Bear Lake, MN 55110 (651) 748-1100 - Fax (651) 748-9370 0. W z N� L.L 0- 0 LU 0 z m N 0 W z rja,24�% 0/20221 w U aaN wC) 00 Y�� Q Qrn� Q�� 0�=z ONO � M CO Q N W Preliminary Issue: 10/20/2022 Bid Issue: 10/20/2022 Landlord Issue: 10/20/2022 Permit Issue: 10/20/2022 Construction Issue: - MECHANICAL FITLE SHEET AND SPECIFICATIONS Comm. Number R22-4301.020 Date 10/20/2022 Drawn By LAK Checked By TMS P0.0 WASTE AND VENT PLAN 1 /4" = 1'-0" DOMESTIC WATER PLAN 1 /4" = 1'-0" GENERAL NOTES WASTE AND VENT RISER N.T.S. A. SUBCONTRACTOR TO VERIFY POINT OF CONNECTION AND SCOPE KEYNOTES O O 3/4" 1 /2" 2" 0 DOMESTIC WATER RISER N.T.S. 1. EXTEND AND CONNECT NEW 2" SANITARY SEWER TO EXISTING 2" (MIN) SANITARY SEWER PIPING. FIELD VERIFY EXACT LOCATION, SIZE, FLOW DIRECTION, AND INVERT ELEVATION OF CONNECTION POINT PRIOR TO ROUGH —IN OF NEW SANITARY SEWER. PROVIDE FCO AT POINT OF CONNECTION TO EXISTING. 2. CONNECT NEW 3/4" CW PIPING TO EXISTING 3/4" (MIN) CW PIPING. FIELD VERIFY EXACT LOCATION OF CW PIPING PRIOR TO ROUGH —IN. PROVIDE SHUTOFF VALVE AT POINT OF CONNECTION TO EXISTING. OF WORK TO INSTALL ALL PLUMBING PIPING & EQUIPMENT TO 3. CONNECT NEW 1-1/2" VENT PIPING ABOVE FLOOD PLAIN OF SPACE PRIOR TO BID. IF INCONSISTENCIES OCCUR BETWEEN PLUMBING FIXTURES TO EXISTING 2" (MIN) VENT. FIELD VERIFY PLANS AND LANDLORD CRITERIA, OWNER'S CONSTRUCTION EXACT LOCATION AND SIZE OF VENT STUB PRIOR TO ROUGH —IN OF MANAGER SHALL BE NOTIFIED PRIOR TO BID SUBMITTAL. NEW VENT SYSTEM. B. IN THE EVENT THAT THE GENERAL CONTRACTOR MUST 4. REPLACE EXISTING WATER CLOSET IN SAME LOCATION. CONNECT PENETRATE THE ROOF, THE OWNER — APPROVED ROOFER NEW WATER CLOSET TO EXISTING PLUMBING IN WALL. MODIFY SHALL BE USED. EXISTING PLUMBING IN WALL AS REQUIRED FOR NEW CONNECTION. PLUMBING FIXTURE SCHEDULE P# FIXTURE NO. FIXTURE TYPE MANUFACTURER TYPE & MODEL N0. TRIM/FAUCET NO. SUPPORT PIPE SIZES REMARKS TRAP WASTE VENT CW HW P1 WATER CLOSET AMERICAN STANDARD CADET WHITE 3305.000 CHICAGO FAUCET 1016 FLOOR MOUNT __ 4 2 1/2" 1.6 GPF, ELONGATED, SIPHON ACTION JETTED BOWL, ADA COMPLIANT 16-1 2" RIM HEIGHT. PROVIDE WHITE SEAT —CHURCH MODEL 295C. P2 LAVATORY AMERICAN STANDARD LUCERNE (WHITE) 0355.012 CHICAGO FAUCET 894-317 WALL HUNG 1-1 /2" 1-1 /2" 1-1 /2" 1 /2" 1 /2" PROVIDE INSULATED CAST BRASS P—TRAP, HANDICAP INSULATION KIT, (2) CHICAGO FAUCET 1016 ANGLE VALVES, WALL CARRIER, 0.5 GPM FLOW LIMIT, ASSE 1070 APPROVED POINT OF USE THERMOSTATIC MIXING VALVES. INSTANTANEOUS WATER HEATER SCHEDULE pp_ UNIT N0. MANUFACTURER I MODEL KW OUTPUT (GPM) TEMP. RISE °F VOLTAGE REMARKS IWH-1 CHRONOMITE LABS, INC. SR-20L 4.16 .5 57 208/1/60 NONE RECEIVED Oct 21 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HALLBERG ENGINEERING Mechanical/Electrical Consulting Engineers 1750 Commerce Court White Bear Lake, MN 55110 (651) 748-1100 • Fax (651) 748-9370 Ire I"%71 j c Nt 0/2022 w U W a Q N 0 00 < Qrn� 0 LU �=Z Z O04O M CD coQ N 0W N 0 O a-0 Q U N W O Z Preliminary Issue: 10/20/2022 Bid Issue: 10/20/2022 Landlord Issue: 10/20/2022 Permit Issue: 10/20/2022 Construction Issue: - PLUMBING PLAN Comm. Number R22-4301.020 Date 10/20/2022 Drawn By LAK Checked By TMS P1.0