REVIEWED FIR2022-0020+Fire_Alarm_Equipment_Specification_Sheets+2.21.2022_11.51.39_AM+2692853(E)POTTER The Symbol of Protection Features F I R2022-0020 RECEIVED Feb 23 2022 CITY OF EDMONDS D€�ELOPnnFNT cFR\/irk DEPARTMENT • 1,270 addresses available on this analog addressable system • Additional system capacity achieved via multi -point SLC modules • 1500 software zones • NFPA 72 Compliant Smoke Sensitivity Test Built -In • System Operates as Class A or Class B for SLC, P-Link and NACs • 10 Amp Power Supply, Expandable to 315 amps • 6 NACS, Regulated, Rated at 3 Amps each, expandable to 192 • 4 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each, • Strobe Synchronization and System Wide Sync for Gentex®, AMSECO®, Cooper Wheelock® and System Sensor® strobes • Dedicated Alarm, Supervisory and Trouble Relays • 4,000 Event History Buffer • Optional two line DACT with UD-2000 that can report General, Zone or Point Information • Built in IP communicator • Ethernet Port for Programming and Network Connectivity • E-Mail System Status, Reports and Event Information • Product includes 5 year warranty Description The AFC-1000 is an expandable analog/addressable releasing fire alarm system with a total system capacity of 1270 addresses. Additional capacity on the system is achieved using multi -point SLC modules The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The AFC-1000 has a 10 Amp power supply with six Notification Appliance Circuits (NACS) and four Input/Output (1/0) circuits. The NACS are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Gentex, AMSECO, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The NACS may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the AFC-1000 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- 1000E has space to allow the installation of up to six PAD100-SLCE SLC loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. ©POTTER AFC-1000 Fire Alarm Control Panel AFC-1000 NYC Fire Dept. O F M Certificate of Approval p ° APPROVED 6256 LISTED 7165-0328:0509 S735 Technical Specifications Dimensions 18 15/16"W x 27 s/16"H x 4'/16"D AC Mains 5.0 Amps @ 120 VAC 50/60 HZ 3.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 mA Alarm Current-200 mA • 10 Amps power for NACS, I/O, and P-Link Battery 3 Amps per NAC, regulated • 1 Amp per I/O circuit, regulated • Battery Charger range 8-55 Ah • Battery Charger voltage 27.3 VDC • P-Link maximum current of 1 Amp Temperature and 320 to 1200 (0°C to 49°C) with a maximum Humidity Range humidity of 93% non -condensing. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830135 - REV G • 11/19 PAGE 1 OF 4 (E)POTTER The Symbol of Protection AFC-1000 Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 1,270 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description AL PAD 100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD 100-PHD Combination Analog Photo Electric Smoke/Heat Detector — a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135' Fahrenheit heat detector. PAD100-HD Analog Fixed (135d-185dF) or Rate -of -Rise Heat Detector (software selectable) PAD 100-DUCTR Addressable Duct Smoke Detector with Form C Relay. Addressable Duct Smoke Detector with Form C relay rated at 10a @ 250/120VAC or 8amps at 30VDC. PAD100-DUCT Addressable Duct Smoke Detector. PAD 100-6B 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD 100-4B 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD100-IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PAD100-CD Addressable CO gas detector. PAD 100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. PAD100-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) PAD100-SPYB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. Modules Device Description PAD100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA Single Action Addressable Pull Station. PAD100-PSDA Dual Action Addressable Pull Station. PAD100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD 100-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PAD100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD 100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD 100-IM Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PAD 100-SM Speaker Module provides switching for two audio channels. PAD 100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD 100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. For use with the PAD 100-DUCTR only. PAD100-0R0I One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830136 - REV G • 11/19 PAGE 2 OF 4 (E)POTTER The Symbol of Protection SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps."Each loop is capable of 127 points, with a max wiring distance of 10,000 ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 4 x 40 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: • AC Power - Green • Alarm - Red • Earth Fault - Amber • Supervisory - Amber • Silenced - Amber • Trouble - Amber • Pre -Release - Amber • Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The AFC-1000 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: PAD100-SLCE-Analog/Addressable loop expansion module SLCE-127 -Nohmi addressable loop expansion module for retrofit applications. AFC-1000 Fire Alarm Control Panel RA-6075R — 2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) — 4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) — 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) — 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in conjunction with the AFC-100 as releasing circuits CA-6500 — Class A convertor that converts the SLC, NACs and P-Link connection UD-2000 — UL listed, Dual line telephone alarm communicator DRV 50 — LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 — Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 — Fiber interface module, used to extend P-Link to multi - mode fiber (2 required) RLY 5 — Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 — Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi -Connect allows up to sixty-three AFC series panels to share a single reporting technology. IDC-6 — Initiating device circuit provides 6 programmable inputs AE-2 — Two card expansion cabinet AE-8 — Eight card expansion cabinet AE-14 — Fourteen card expansion cabinet Ethernet/I.P. Connection The AFC-1000 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur -Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830136 - REV G • 11/19 PAGE 3 OF 4 (E)POTTER The Symbol of Protection Dimensions 18.91 " 17.60" TOP o ° O Oo 0 0 0 0 04 LEFT SIDE BOTTOM Ordering Information Model Description Stock No. AFC-1000 Fire Alarm Control Panel 13992754 Replacement Board AFC-1000 13992758 AFC-1000 Fire Alarm Control Panel 4.41" 3.75" DEPTH SIDE Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830136 - REV G • 11/19 PAGE 4 OF 4 'W�4" ,, ES,�� of SECURITY CORPORATION INNOVATION 7707 Fire Subscribers IntelliNet A Newer, Smarter Alarm Communications Platform Feature Highlights • Leverages state of the art technology • Applies advanced security protection • Offers flexible power and configuration options • Engineered for backward compatibility with legacy systems • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes robust Multiple Communication Technologies (MCT) feature • Emulates virtual keypad • Improves functionality with an adaptive Graphic User Interface (GUI) for programming via smartphones, tablets and PCs • Plus many more... Key Benefits M AU 1-1(90NNFPALISTED • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password -protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP) without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3) Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option, they are the ideal drop -in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D) BurglaryD _ Subscriber — — — — — — — — — lam B ♦ 1 1_1 _ C B) Fire / N i Subscriber 1 1 I AES-Network Management System D — — — B _ _ _ _ _ — — — — — — — — 705BE �— — — PrimaryAES-MultiNet Receiver I ♦ �� I I ♦ I A) Alarm Panel Secondary AES-MultiNet Receiver ♦ I ♦ 1 I •• B ♦♦ E B Alarm Automation A — _ — _ _ I C)IP Links Customer Location I Mesh Radio Technology I Central Monitoring Station Alarm Panel & AES Subscriber Multi -path AES-IntelliNet@ Network Primary & Secondary AES-MultiNet System sends critical event signal delivers alarm signals via smart routing receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add -on accessory board. AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources How to Order 7707 Fire InteffiNet 2.0 Fire Subscribers 2.0 PREMIUM (UL & ULC Listed) 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) with Multiple Communication Technologies (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES 7794A Standalone AES-IntelliPro Fire full data module add -on accessory board with firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy. .- 7706-ULF Integrated Fire Monitoring System, Red Enclosure 7788F-ULP-P Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module, 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7788F-ULP Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module, 7744F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure 7744F-ULP Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, Red Enclosure 7744F Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones, Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add -on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS 13"H x 8.5"W x 4.5"D (33cmH x 21.5cmW x 11.4cmD) WEIGHT 5.8 Ibs (2.6 kilograms) excluding battery 13 Ibs (5.9 kilograms) with 10 Ah battery RADIO FREQUENCY Standard Frequency Range: 450-470 MHz Contact AES for other UHF and VHF frequencies ANTENNA 2.5 dB tamper resistant antenna included, mounts on enclosure Optional remote mounting antenna available POWER INPUT AC SOURCES Transformer: Class 2 16.5V AC nominal output 1.9 A max current (40 VA MIN) ELK ELK-TRG1640, MG ELECTRONIC SALES MGT1640, or AES 1640 (not included) DC SOURCES (includes FACP) 24V DC Regulated Power Supply with Subscriber Rechargeable Battery 1.9 A max current BACKUP BATTERY 10-12 Ah, UL recognized lead acid gel cell, size based on subscriber configuration Contact Us ALARM SIGNAL INPUTS/ZONES 8 individually programmable E.O.L. type zone inputs 4+4: 4 reverse polarity input and 4 individually programmable E.O.L. type zone inputs Optional 7794A AES-IntelliPro for full data via Contact ID, Pulse, Modem Ile and Modem IIIa2 UL LISTINGS UL 864 loth Edition Standard for Control Units and Accessories for Fire Alarm Systems ULC S559-04 1st Edition Equipment for Fire Signal Receiving Centres and Systems TROUBLE OUTPUT—ACK DELAY/ANTENNA CUT Form C relay, fail secure, rated 24V DC 1A resistive, unsupervised RESET BUTTON Located on main circuit board OPERATING TEMPERATURE 32 to 120°F (0 to 49°C) STORAGE TEMPERATURE 14 to 140°F (-10 to 60°C) RELATIVE HUMIDITY 0 to 93%, non -condensing RECHARGE CAPABILITY Will charge 12V battery size from 10-12 Ah PORTS Ethernet for configuration and message communication USB access for software upgrade REMOTE ANNUNCIATOR AES Model 7740 Remote Annunciator, supervised COMPATIBLE RECEIVERS 7705i AES-MultiNet Receiver CONFIGURATION INTERFACE Web browser capable device accessible via smartphone, tablet, laptop, or PC CURRENT CONSUMPTION Standby w/ charged backup battery: 200 mA (1.2 A Transmitting) Standby + charging backup battery: 900 mA (1.9 A Transmitting - MAX) POWER OUTPUT 2 or 5 Watts Factory set ENCLOSURE MATERIAL Steel with paint finish FINISH COLOR Red VISUAL INDICATORS Front panel LCD (2 x 20 alphanumeric character backlit display) Power and Trouble LEDs (ALM, Trouble, Tx, Rx, WA) For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. (E)POTTER The Symbol of Protection Features • Single or Dual Action versions • Durable die-cast construction • Reset key matches the fire alarm control panels • Compatible with IPA Series panels • SLC Class A, Class X & Class B • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The PAD100-PSSA (Single Action) is activated by simply pulling the white "T" bar handle down. The PAD100-PSDA (Dual Action) is activated by lifting the front cover and then pulling the white "T" bar handle down. Once activated, the "T" bar cannot be reset without opening the front cover. Opening the front cover will also activate the pull station. To reset the PAD 100-PS Series, use the Potter WS-93 key to unlock and open the front cover. Once the cover is open, push the "T" bar back into the normal position and re -secure the front cover. Application The PAD 1 00-PSSA/PSDA is compatible with Potter's IPA and AFC/ ARC series addressable fire alarm control panels. It is a non -coded addressable pull station available in either a single or dual action model and installs on a single gang box or surface mounts using the P32-BB or P32-DBB (deep) back box. PAD 100-PSSA/PS DA Addressable Pull Station Single/Dual Action �RO U`9�R . w<AP(� Technical Specifications Operating Voltage 24.0 VDC Max SLC Standby Current 200uA Max SLC Alarm Current 200uA 32°F - 120°F (0° - 49°C) Environmental Limitations Indoor Only Dimensions 4.75" H x 3.25" W x 1.75" D Relative Humidity Range 0 - 93% (non -condensing) Single gang box or Mounting Options Potter P32-BB/DBB APS-SA - 1.22 lbs. [ZppingWei t APS-DA - 1.46 lbs. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830097 - REV D • 12/18 PAGE 1 OF 2 PAD 100-PSSA/PSDA (E)POTTER Addressable Pull Station The Symbol of Protection Single/Dual Action Setting the Address The PAD 100-PS Series uses one SLC address assigned to the device. The address is set using the DIP switch located on the back of the PAD 100-PS device. Pull Station Front View Fig 1 o-_ Hn c jz p U ©PorTER PAD100-PSDA Pull Station Back View and Wiring Fig 2 FROM FACP OR PREVIOUS DEVICE TO NEXT DEVICE Ordering Information 0 Model Description Stock No. PAD100-PSSA Addressable Pull Station, Single Action 3992721 PAD100-PSDA Addressable Pull Station, Dual Action 3992720 U POTTER PAD 100-PSSA WIRED CONTACTS 0 0 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830097 - REV D • 12/18 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • Single module with dual contact monitoring inputs • Two (2) Class B or one (1) Class A monitoring inputs • SLC Class A, Class X & Class B • Mounts in a standard 4" or double gang box • Wiring terminals accessible when mounted in box • All wiring terminals accept 22 to 12 AWG • Product includes a 5 year warranty • UUKL Listed for Smoke Control NOTE: This addressable module does not support 2-wire smoke detectors. Description The PAD100-DIM uses one (1) SLC loop address when monitoring two (2) Class B circuits or one (1) Class A circuit. The module mounts on either a 4" square or double gang box. The module is capable of monitoring two (2) separate class B circuits making it ideal for monitoring sprinkler waterflow and valve tamper switches when they are located in the same proximity. The PAD 100-DIM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When an input is activated, the LED will flash at a fast rate. Application The PAD 100-DIM is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD100-DIM is an interface module used to monitor dry contact devices such as sprinkler waterflow, valve tamper switches, or conventional pull stations. The module is capable of monitoring two separate Class B or one Class A circuits. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD100-DIM. When the PAD100- DIM is used to monitor two individual Class B circuits a single device address is assigned, each input is then identified as a sub -point of the module address. For example, if the address number is assigned as "8", the first input will be "8.1" and the second input will be "8.2". Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: 1. Power to the device is removed. 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. PAD100-DIM Dual Input Module ®? J ASEMB��O i2 PHE VIP F M Ok S APPROVED Technical Specifications Operating Voltage 24.OV Max SLC Standby 240µA Current Max SLC Alarm 240µA Current Max Wiring Resistance 10012 of IDC Max Wiring INF Capacitance of IDC EOL Resistor 5.lK f2 Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non -condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L x 4.17" (I06mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.61bs Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830082 - REV D • 12/18 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Installation Using Compatible Electrical Box Fig 1 Wiring Diagrams PAD100-DIM With One Class A Circuit Fig 2 0 FROM FACP OR PREVIOUS MODULE ® TO NEXT MODULE sLc }J ® ® 1 IN7 ® INP ® J®PM10Dg1 0 (:�D 0 G NOTE: END -OF -LINE RESISTOR IS NOT REQUIRED PAD100-DIM With Two Class B Circuits Fig 3 FROM FACP OR PREVIOUS MODULE TO NEXT MODULE END -OF -LINE RESISTOR aa:[ 5.`IKOHM,�W Part #3005013 END -OF -LINE RESISTOR a:r:r[ 5.1KOHMY2W Part #3005013 Ordering Information Model Description Stock No. PAD100-DIM Dual Input Module 3992703 MOVE THE "CL-A" DIP SWITCH TO "UP" POSITION FOR CLASS A WIRING MOVE THE "CL-A" DIP SWITCH TO "DOWN"POSITION FOR CLASS B WIRING PAD100-DIM Dual Input Module Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830082 - REV D 12/18 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • UL 268 7th Edition • Low profile, less than 2 inches with the base • Wide selectable sensitivity range of 1.0 to 3.7%/foot • Sensor communicates sensitivity to control panel • UL listed smoke calibration and sensitivity • Optional locking tab to prevent unwanted removal • Simple DIP switch address setting, no programming tool required • LED alarm indicator • Product includes a 5 year warranty • UUKL Listed for Smoke Control Description The Photoelectric Smoke Sensor is a listed Analog Addressable smoke sensor compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD200-PD is a low profile smoke sensor with a wide sensitivity range. The sensor and base (not included) are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD200-PD has a sensitivity range of 1.0 to 3.7 % per foot and is UL. The PAD200-PD features drift compensation and has built in dirty detector warning as well as. The PAD200-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD200-PD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: 1. Power to the device is removed 2. Field wiring is correctly installed. 3. Field wiring has no open or short circuits. PAD200-PD Photoelectric Smoke Sensor UL LISTED Technical Specifications Operating Voltage 24 VDC Detector Current Draw 300 µA Alarm indicator 1 LED Alarm set -point range 1.0 to 3.7 %/ft 3.6-12 %/m Installation temperature 32 to 120 ° F / 0 to 49 ° C range Operating relative 0% to 93% (Non -condensing) humidity range Start-up time Max. 1 sec. Maximum number of 127 addresses per loop Maximum number of lighted indicators in 30 alarm per loop. Color Eggshell White Weight (without base) 101g (3.56oz) Dimensions (without Height: 1.35 in (34mm) base) Diameter: 3.93 in (100 mm) Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830172 - REV A • 5/21 PAGE 1 OF 2 (E)POTTER The Symbol of Protection Air Velocity Ratings The PAD200-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. PAD200-PD Photoelectric Smoke Sensor The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD200-PD will operate even though the LED may not illuminate. Operation The PAD200-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD200-PD with the PAD 100-4DB or PAD 100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD200-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned or replaced. The PAD200-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE. As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing The PAD200-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4" Standard Base 3992731 PAD100-6DB 6" Standard Base 3992732 PAD100-IB 6" base with an isolator module included. 3992730 PAD100-RB 6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125VAC 3992728 PAD 100-SB 6" base with sounder module included. Sound pattern is provided from external source. 3992729 PAD100-SPKB 6" base with speaker included 3992762 Ordering Information Model Description I Stock No. PAD200-PD Photoelectric Smoke Sensor 3992770 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830172 - REV A • 5/21 PAGE 2 OF 2 (E)POTTER The Symbol of Protection Features • Listed for indoor and outdoor use • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4" box • Low current draw • High dB output • AC and DC models • DC models are motor driven, polarized, and have built in transient protection for supervised alarm circuits • Available in 6", 8" and 10" sizes Description These vibrating type bells are designed for use as fire or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 or HC-BB weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1 or HC-BB, Stock No. 1500001. Notes 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30' to 150°F (-34° to 66°C) 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to PDC-DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150) 12VDC PDC-6-12 1750500 200mA 96 76 8 (200) 12VDC PDC-8-12 1750502 .200mA 96 77 10 (250) 12VDC PDC-10-12 1750504 .200mA 96 78 6 (150) 24VDC PDC-6-24 1750501 .20mA 95 77 8 (200) 24VDC PDC-8-24 1750503 20mA 83 79 10 (250) 24VDC PDC-10-24 1750505 20mA 85 80 6 (150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6 (150) 120VAC PBA1206 1806120* .05A 92 83 8 (200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. Potter Electric Signal Company, LLC St. Louis, MO BELLS PBA AC & PDC-DC * ** U` U C FM � �: ®@ APPROVED ma.... * ULC on PDC-DC Only ** FM on PBA-AC Only Technical Specifications Dimensions 6" (150mm), 8" (200mm) and 10" (250mm) Cover: Steel Finish: Red Powder Coat Enclosure Base: non -corrosive composite material All parts have corrosion resistant finishes Model BBK-1 or HC-BB weatherproof backbox (optional) 24VAC Voltages Available 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Indoor or outdoor use (See Note 1) Environmental -400 to 150OF (-400 to 66°C) Limitations (Outdoor use requires weatherproof backbox.) AC Bells - 4 No. 18 AWG stranded wires Termination DC Bells - 18 AWG stranded wire Service Use NFPA 13, 72, local AHJ *Specifications subject to change without notice. W WARNING Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. WEE6:W:A:RNING In outdoor or wet installations, bell must be mounted with rweatherproof backbox, BBK-1 or HC-BB. Standard electrical boxes will not patherproofenclosure. If the bell and/or assembly is exposed to moisture,r create an electrical hazard. Phone: 800-325-3936 www.pottersignal.com 5400777 - REV A • 12/20 PAGE 1 OF 2 (E)POTTER BELLS The Symbol of Protection PBA AC & PDC-DC Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 1. Remove the gong. 2. Connect wiring (see Fig. 3). 3. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). Weatherproof Backbox Dimensions WARNING Inches (mm)WF.i1tuue,..inst.a11 striker down will prevent bell from ringing. MODEL BBK-1 OR HC-BB Fig 2 Bell Dimension Inches (mm) Fig 1 5 3/4" O 046 —) 10" (250mm) 8„ ----� — (200 mm) 6" (150 mm) J J (41 mm) L 2 11/16" (68 mm) DWGq 776-1 Wiring Rear View Fig 3 D.C. BELLS (OBSERVE POLARITY) A.C. BELLS 338' (86 —) 4 1/4" (108 —) 3 3/8" 5" (86—) (127—) RED (IN) RED (OUT) WHITE (IN) WHITE (OUT) 0 0 FROM CONTROL PANEL CIB EXT BELL FROM CONTROL PANEL OR D-OF-LINE OR PRECEDING BELL SISTOR PRECEDING BELL BLACK (IN) T) BLACK (IN) CBLACK CAUTION• WHEN ELECTRICAL SUPERVISION 15 REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: CAUTION; WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN - NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY 2. RED WIRES POSITIVE (+). AFTER LAST BELL. 3. BLACK WIRES NEGATIVE (-). 2. END -OF -LINE RESISTOR IS NOT REQUIRED ON AC BELLS . 4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5400777 - REV A • 12/20 PAGE 2 OF 2 (E)POTTER ® The Symbol of Protection Features • Super -Slide® Bracket — Ease of Supervision Testing • Wall or Ceiling mount • Checkmate® — Instant Voltage Verification • Synchronize horn with Potter GTSM module • Produces a 520Hz square wave, temporal 3 tone • Jumper selection for normal or loud dBA • Temporal 4 pattern available when used with GTSM module • Tamperproof re-entrant style grill and locking screw (Optional) • Faceplate available in red or off white • 5 year warranty LFH Series Low Frequency Audible Sounder SIGNALING U� LISTED S3247 Application Product Listings The LFH Series is a high quality, low profile, audible appliance Listed to ANSI/UL 464 and CAN/ULC S525 designed to meet the NFPA 72 requirements to install low frequency CSFM: Pending (520Hz) signaling in sleeping rooms. Description The LFH horn offers a 520Hz square wave, temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Potter GTSM Synchronization Control Module. The LFH is equipped with a universal 4" metal mounting bracket which incorporates the popular Super -Slide® feature that allows the installer to easily pre -wire the system and test for supervision. The product also features a locking mechanism that secures the signal to the bracket without showing any screws and the Checkmate® - Instant Voltage Verification Feature which allows the installer to check the voltage drop, current draw, and match against the blue print. Technical Specifications Operating Voltage I Nominal 24VDC (16-33VDC) Operating Temperature 320F - 120°F (0° - 49°C) Dimensions 6-1/8" H x 5 1/2" W x 1-5/8" D Wiring Connections Terminals accept 18 - 12 AWG Mounting Single gang, double gang, or 4" square back box Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8830068 - REV A • 4/15 PAGE 1 OF 3 (E)POTTER The Symbol of Protection Ordering Information Model Number Stock Number Body Color LFH-24R 4890070 Red LFH-24W 4890071 Off -White Horn Levels: Reverberant Room Horn Setting Minimum dBA at 10', Per UL 464 (NORMAL) Minimum dBA at 10', Per UL 464 (HIGH) Temporal 3 520 Hz 77.8 dBA 79.8* dBA Temporal 4* 520 Hz 81.5 dBA 83.4* dBA LFH Series Low Frequency Audible Sounder Model Designations "R" = Red "W" = White All units are plain (no lettering) 24VDC Normal Horn Current Rating (mA) Horn Setting 24VDC Operating Current (NORMAL) 24VDC Operating Current (LOUD) 24VFWR Operating Current (NORMAL) I24VFWR Operating Current (LOUD) Temporal 3 520 Hz 72.1 mA 120.1 mA 104.6 mA 158.4 mA Temporal 4* 520 Hz 75.9 mA 116.0 mA 108.1 mA 182.0 mA Horn Current Ratings Over Input Voltage Range of 16-33V (mA) Horn Setting Regulated 24VDC Max Operating Current (NORMAL) Regulated 24VDC Operating Current (LOUD) Regulated 24VFWR Max. Operating Current (NORMAL) Regulated 24VFWR Max. Operating Current (LOUD) Temporal 3 520 Hz 99.4 mA 155.8 mA 152.1 mA 213.5 mA Temporal 4* 520 Hz 100.1 mA 157.2 mA 163.1 mA 235.2 mA * Temporal 4 520 Hz measured per ANSI/UL 2075 • For nominal and peak current across ANSL UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. • RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units). For unfiltered FWR ratings, see installation manual. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSL UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8830068 - REV A • 4/15 PAGE 2 OF 3 (E)POTTER The Symbol of Protection NOTES. LFH Series Low Frequency Audible Sounder uL Listed Control This appliance is not recommended for use on coded or pulsing signaling p. p S g Panel signal signal C1YCUltS. S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised e B e e The four pulse temporal pattern (temporal 4) can only be obtained on this Signal Circuit product when used in conjunction with the Potter GTSM Synchronization \ + END OF LINE RESISTOR Module See GTSM Control Module Manual (???) for synchronization module wiring diagram. GTSM Manual can be obtained at www.Pottersignal.com/fire or call Potter Technical Support 1866-956-1211 ■I 1118401O "* Checkmate® Instant Voltage Verification It is often necessary to confirm the voltage drop along the line of devices. The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically, this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. NOTE: Care should be taken to not short the test probes. Normal -loud decibel jumper. For loud decibel install jumper Super Slide® Mounting Bracket Allows the installer to pre -wire the system, test for system supervision, remove the signal head until occupancy, switch out signals without changing mounting brackets and has locking edge connector for snap-m- place installation. Architect and Engineering Specifications Locking S (optional) Locking S (optional) Slide onto bracket The alarm horns shall be Potter model LFH. The appliance shall be listed with Underwriters Laboratories (ANSI/UL) for use with fire protective signaling systems (ANSI/UL 464) and with CAN/ULC S525 with intended use in fire alarm systems. The LFH will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 1so 9001:2008 1 DESIGNING, MANUFACTURING, MIMES 8 DISTRIBUTING QUALITY SYSTEMS 8830068 - REV A • 4/15 PAGE 3 OF 3 (E)POTTER ® The Symbol of Protection Features • Fixed 75cd strobe • Includes the WPBB surface -mount (standard) or WPLPBB Low Profile (LP) enclosure • WPBB/LP made of clear Lexan® - provides maximum visibility and reliability, allowing full 75cd output • Super -Slide® Bracket — Ease of supervision testing • Checkmate® - Instant voltage verification • Synchronize strobe and/or horn with AVSM module • Switch selection for high/low dBA • Switch for chime, whoop, mechanical, and 2400Hz tone • Input terminals accept 18 to 12 AWG • Switch for continuous or temporal 3 tone (not available on whoop) • Tamperproof re-entrant grill • 5 year warranty Application The S/HS-WP Series Outdoor Signals are wall mount, low profile strobes and hom/strobes that offer dependable audible and visual alarms for warning and emergency notification in outdoor locations. Description The S/HS-WP Series Outdoor Signals are 24VDC strobes and horn/ strobes equipped with a fixed 75 candela strobe. This series of outdoor signals are available in two different versions. The standard version includes a surface -mount back box (WPBB) to install directly on a wall. The Low Profile (LP) versions includes a low profile back box (WPLPBB) designed to be installed on a flush - mounted electrical box. The weatherproof enclosure is made of clear Lexan® which provides maximum visibility and reliability for effective visible signaling, allowing full 75cd output. The S/HS-WP series strobe has a minimal operating current and a minimum flash rate of 1Hz regardless of input voltage. The strobe is synchronized using Gentex sync. protocol or the AV SM Sync. Module. The S/HS-WP Series is equipped with a universal 4" mounting bracket which incorporates the popular Super -Slide® feature that allows the installer to easily pre -wire the system and test for supervision. The product also features a locking mechanism that secures the signal to the bracket without showing any screws and the Checkmate® - Instant Voltage Verification Feature which allows the installer to check the voltage drop, current draw, and match against the blue print. S/HS-WP Series Outdoor Strobes and Horn/Strobes LP Version Standard WGNAUxs UL LISTED S3247 Product Listings • ANSI/UL 464 and 1638 • Complies with American with Disabilities Act (ADA) • Complies with IBC / IFC / IRC Technical Specifications Operating Voltage I Nominal 24VDC (16-33VDC) Operating -31°17 - 150°F (-35° - 66°C) Temperature LP Version - 5.75" H x 4.75" W x 3.25" D Dimensions Standard - 5.75" H x 4.75" W x 4.18"D Wiring Connections Terminals accept 18 - 12 AWG LP Version — Single gang, double gang, or 4" square back box Mounting Standard Version - Surface mount back box included Shipping Weight 2.05 lbs. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8830057 - REV B • 3/15 PAGE 1 OF 4 (E)POTTER The Symbol of Protection S-24-WP, 75 Candela, Outdoor Strobe Includes Standard or LP Enclosure Model Number Stock Number Body Color WP Enclosure S-24WR-WP 4890050 Red Standard S-24WW-WP 4890051 Off -White Standard S-24PWR-WP 4890052 Red -Plain Standard S-24PWW-WP 4890053 Off -White -Plain Standard SLP-24WR-WP 4890054 Red Low Profile SLP-24WW-WP 4890055 Off -White Low Profile SLP-24PWR-WP 4890056 Red -Plain Low Profile SLP-24PWW-WP 1 4890057 1 Off -White -Plain Low Profile S/HS-WP Series Outdoor Strobes and Horn/Strobes Model Designations "W" = Wall Mount "R" = Red Face Plate "W"=Off- White Face Plate "P"= Plain (Note: Plain units are non -returnable) "LP"= Low Profile (WPLPBB Enclosure) Strobe Current Ratings Candela 75 cd 24 VDC 112 mA UL Max 170 mA NOTE: Forunfiltered FWRratings, see installation manual. HS-24-WP Series, 75 Candela, Outdoor Horn /Strobe Includes Standard or LP Enclosure Model Number Stock Number Body Color Reverberant dBA at 10', per ANSVUL 464 In Anechoic Room dBA at 10' WP Enclosure HS-24WR-WP 4890060 Red 70-82 100 Standard HS-24WW-WP 4890061 Off -White 70-82 100 Standard HS-24PWR-WP 4890062 Red -Plain 70-82 100 I Standard HS-24PWW-WP 4890063 Off -White -Plain 70-82 100 Standard HSLP-24WR 4890064 Red 70-82 100 Low Profile HSLP-24WW 4890065 Off -White 70-82 100 I Low Profile HSLP-24PWR 4890066 Red -Plain 70-82 100 Low Profile HSLP-24PWW 4890067 Off -White -Plain 70-82 100 Low Profile Horn Decibel and Current Ratings Horn Setting Minimum dBA at 10', Per UL 464 (HIGH) Minimum dBA at 10', Per UL 464 (LOW) Regulated 24VDC Max. Operating Current, at High Setting (mA) Temporal 3 2400Hz 78 71 * I 28 Temporal 3 Mechanical 76 70* I 25 Temporal 3 Chime 70* 66* 15 Continuous 2400Hz 81 74* I 28 Continuous Mechanical 80 72* I 25 Continuous Chime 1 70* 66* 15 Whoop 1 82 1 69* 56 *Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8830057 - REV B • 3/15 PAGE 2 OF 4 (E)POTTER The Symbol of Protection Tone Switch Locations Tone Switch Position 3 4 5 Mechanical Temporal 3 ON ON ON Mechanical - Continuous OFF ON ON 2400Hz - Temporal 3 ON OFF ON 2400Hz - Continuous OFF OFF ON Chime - Temporal 3 ON ON OFF Chime - Continuous OFF ON OFF Whoop ON OFF OFF Whoop OFF I OFF OFF NOTES. • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON = HIGH dBA • Switch Position 6 OFF = LOW dBA Super Slide® Mounting Bracket Allows the installer to pre -wire the system, test for system supervision, remove the signal head until occupancy, switch out signals without changing mounting brackets and has locking edge connector for snap -in -place installation. tip Mounting Outdoor Enclosure Super Slide® Mounting Plate: Mounts to WPBB Outdoor Enclosure S/HS-WP Series Outdoor Strobes and Horn/Strobes S¢ S¢ S_ H+ H_ ate® Instant Voltage ion necessary to confirm the voltage ig the line of devices. The access provided in the back of the block to allow the voltage to fired directly without removing e. Typically, this would be done d of the line to confirm design ✓lost measurements will be taken S+ and S- locations although provided to other locations. Care should be taken to not short the test probes. Super Slide® Mounting Plate: Mounts to WLPBB Outdoor Enclosure Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com 8830057 - REV B • 3/15 PAGE 3 OF 4 (E)POTTER The Symbol of Protection UL Listed Centr0I - Signal - Signal Panel ' R y S/HS-WP Series Outdoor Strobes and Horn/Strobes Wiring Diagrams 1 RUM �I UL Listed Control Signal Signal Panel S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised Signal Circuit \+ END OF LINE END OF LINE RESISTOR RESISTOR END OF LINE RESISTOR NOTES. • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. Architect and Engineering Specifications The audible and/or visible signal shall be Potter S/HS-WP Outdoor Series or approved equal and shall be listed by Underwriters Laboratories Inc. per ANSF UL 1638 and/orANSFUL 464. The notification appliance (combination audible/visible) shall produce a peak sound output of 100dBA or greater at as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 112mA or less for the 75Cd strobe circuit. The appliance shall also be capable of meeting the candela requirements of the ADA (75cd). The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models. The appliance shall be capable of testing supervision without disconnecting wires. Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. The appliance has extended temperature range of -31° to 150°F (-35° to 66' Q. The appliance shall satisfy virtually all outdoor and severe environment applications. The WPBB enclosure includes a gasket that must be inserted between the box and mounting bracket. There are drain holes in the back box to allow for drainage, the seal on the WPBB enclosure is not water tight. The WPLPBB enclosure includes a weather seal for mounting to wall and intended for use with universal electrical box. To allow for drainage, bottom edge of enclosure is not water tight. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 • www.pottersignal.com ISO 9001:2008 1 DESIGNING, MANUFACTURING, 8 DISTRIBUTING QUALITY SYSTEMS 8830057 - REV B • 3/15 PAGE 4 OF 4 CPOTTER The Symbol of Protection Ordering Information Stock Number Model Number Model Designations 4890005 EH-24R R = Red facepalte 4890006 EH-24W W = Off -White faceplate 4890007 EH-24PR P = Plain 4890008 EH-24PW SIGNALING U� LISTED Product includes a 5 year warranty Description The EH24 Series is a low profile electronic horn that offers dependable audible output at the lowest current available. The EH24 Series horn offers a continuous or synchronizable temporal three in 2400Hz and mechanical tone, a chime, and whoop tone. All tones are easy for the professional to change in the field by using switches. EH24 SERIES ELECTRONIC HORN Features • Nominal voltage 24 VDC • Horn is available in 12 VDC or 24 VDC • Super -Slide Bracket - ease of supervision testing • Checkmate® - instant voltage verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system, install mounting bracket, then install signals • Documented lower installation and operating costs • Input terminals 12 to 18 AWG • Switch selection for high or low dBA • Switch for chime, whoop, mechanical, and 2400 Hz tone • Switch for continuous or temporal 3 (not available on whoop tone) • Tamperproof re-entrant grill • Surface mount with the AVBB (Surface Back Box) • Silence horn while strobes remain flashing • Faceplate available in red or off-white Dimensions • 5" (12.7 cm) height x 4.5" (11.43 cm) wide x 2.5" (6.35 cm) deep Operating temperature • 320F to 120OF (0°C to 49°C). The EH-24 Series is not listed for outdoor use. The EH24 Series is s hiped with the standard 4" mounting plate which incorporates the popular Super -Slide® feature that allows the installer to easily test for supervison. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The EH24 Series also features the patented Checkmate® - Instant Voltage Verification feature, which allows the installer to check the voltage drop draw and match it to the blueprint. PotterElectric Signal Company,LLC • St. Louis,MO 63042 USA• CustService: 866-572-3005 -Tech Support: 866-956-0988 • Canada 888-882-1833 •www.pottersignal.com PRINTED IN USA MFG. #8830053 - REV A PAGE 1 OF 3 06/13 CF POTTER The Symbol of Protection Tone Switch Locations TONE SWITCH POSITION 3 4 5 Mechancial Temporal 3 ON ON ON Mechancial - Continuous OFF ON ON 2400Hz - Temporal 3 ON OFF ON 2400Hz - Continuous OFF OFF ON Chime - Temporal 3 ON ON OFF Chime - Continuous OFF ON OFF Whoop ON OFF OFF Whoop OFF OFF OFF NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs. • Switch Position 6 ON = HIGH dBA • Switch Position 6 OFF = LOW dBA Super -Slide® Mounting Bracket Allows the installer to pre -wire the system, test for system supervision, remove the signal head until occupancy, switch out signals without changing mounting brackets and has locking edge connector for snap -in place installation. To remove bezel, grip both sides of bezel and pull in a downward and outward motion. ■ EH24 SERIES ELECTRONIC HORN Checkmate® Instant Voltage Verification It is often necessary to confirm the voltage drop along a line of devices. The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. NOTE: Care should be taken to not short the test probes. PotterElectric Signal Company, LLC • St. Louis, MO 63042 USA- CustService: 866-572-3005 -Tech Support: 866-956-0988 • Canada 888-882-1833 •www.pottersignal.com PRINTED IN USA MFG. #8830053 - REV A PAGE 2 OF 3 06/13 c POTTER The Symbol of Protection EH24 SERIES ELECTRONIC HORN EH-24 Product Horn Decibel and Current Ratings Horn Mode Minimum dBA @ 1 Oft. per ANSUUL 464 (HIGH) Minimum dBA @ 1Oft. per ANSI/UL 464 (LOW) Regulated 24 VDC Max. Operat- ing @ High Setting (mA) Temp 3 240OHz 78 71 * 28 Temp 3 Mechancial 76 70* 25 Temp 3 Chime 70* 66* 15 Continuous 240OHz 81 74* 28 Continuous Mechancial 80 72* 25 Continuous Chime 70* 66* 15 Whoop 82 69* 56 NOTES: • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. 12VDC models are DC only. * Operating the hom in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). Architect & Engineering Specifactions The audible and/or visible signal shall be Potter EH24 Series or approved equal and shall be listed by Underwriters Laboratories Inc. per ANSI/UL 464. The notification appliance shall also be liited with the California State Fire Marshal (CSFM). The notification appliance shall produce a peak sound output of 100 dBA or greater at 12 VDC or 24 VDC as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires, verify voltage without removing unit, and be capable of mounting to a surface back box. GEH 24 VDC Low Profile Evacuation Horn Model Number Part Number Nominal Voltage Reverberant dBA @ 1 Oft., per ANSI/UL 464 In Anechoic Room dBA @ loft. GEH24-R 904-1205-002 24 VDC 70-82 100 GEH24-W 904-1207-002 24 VDC 70-82 100 Model Designations: W = Wall Mount R = Red Faceplate W = White Faceplate All units are available in plain (no lettering). Plain units are non -returnable. ALERT bezel available AGENT bezel available PotterElectric Signal Company, LLC • St. Louis,MO 63042 USA- CustService: 866-572-3005 -TechSupport: 866-956-0988 • Canada888-882-1833 •www.pottersignal.com PRINTED IN USA MFG. #8830053 - REV A PAGE 3 OF 3 06/13