Loading...
BLD2023-0202_Structural_Calculations_2.16.2023_10.17.37_AM_3373117STRING CALCULATIONS ENPHASE : IQ8M-72-2-US (240V) STRING #1 STRING #2 STRING #3 MAX AC CURRENT 13.54A 13.54A 11.85A MICRO INVERTER(S) IN SERIES: 8 8 7 NOMINAL VOLTAGE / RANGE 211V - 264V 211V - 264V 211V - 264V MAX AC OUTPUT POWER: 260OW 260OW 2275W ARRAY DC POWER: 10350W TOTAL MAX AC CURRENT: 31.15A NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES 4-6 .80 7-9 .70 10-20 .50 SYSTEM OCPD CALCULATIONS INVERTER MODEL(S): EN PHASE IQ8M-72-2-US (240V) # OF INVERTER(S): 23 MAX OUTPUT CURRENT: 1.35A (# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING (23 X 1.35A X 1.25) = 38.93A <= 40A, OK PV LOAD CALCULATIONS: SUPPLY SIDE TIE-IN FEEDER WIRE RATING: 200A ALLOWABLE SOLAR CALCULATION (FEEDER RATING - 1.25) 160.000OA (FEEDER WIRES ALLOWABLE SOLAR) 160.000OA (AVAILABLE FOR PV) Conduit & Conductor Schedule TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SIZE CONDUCTOR RATING CONDUCTOR TEMP. RATE AMBIENTTEMP TEMP. DERATE # OF CONDUCTORS DERATE CONDUCTOR RATING W/DERATES CONDUIT FILL 1 (2) 12 AWG Q-CABLE , COPPER (L1, L2) N/A - FREE AIR 30A 900C 260C 1.0 N/A - FREE AIR 30A N/A - FREE AIR (1) 12 AWG THWN-2 COPPER- (GROUND) 2 (2) 10 AWG THHN/THWN-2, COPPER - (L1, L2) 3/4" PVC 40A 90°C 26°C 1.0 1.0 40A 12.03% (1) 10 AWG THWN-2 COPPER - (GROUND) 3 (6) 10 AWG THHN/THWN-2, COPPER - (L1, L2) 3/4" PVC 40A 90°C 26°C 1.0 0.8 32A 28.07% (1) 10 AWG THWN-2 COPPER - (GROUND) 4 (3) 8 AWG THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) 3/4" PVC 55A 90°C 26°C 1.0 1.0 55A 28.07% (1) 8 AWG THWN-2 COPPER - (GROUND) 5 (3) 6 AWG THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) 3/4" PVC 65A 75°C 26°C 1.0 1.0 65A 38.37% (1) 6 AWG THWN-2 COPPER - (GROUND) GROUNDING & GENERAL NOTES: 1. PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE. 2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. INTERCONNECTION NOTES: 1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC 705.121, AND [NEC 690.64]. 2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5] 3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE -BREAK SWITCH S L A R Revolution Energy Systems Inc. 9981 West 190th St Unit K Mokena IL 60448 T: 708-995-1643 SITE INFORMATION NATHAN MOSS 19220 76TH AVE W SEATTLE, WA 98133 AC System Size: 7.48 kW AC / 7.48 kVA DC System Size: 10.35 kW DC Lat, 47.82465 Long,-122.33644 (23) CANADIAN SOLAR CSW3-45OMS (450W) PV Modules (23) ENPHASE IQ8M-72-2-US (240V) Inverter(s) SNOHOMISH COUNTY PUD DRAWN BY: ALINSUG W. DATE: 2/3/2023 ELECTRICAL CALCS - PV06