ENG2023-0018 ROW PERMITRIGHT PERMIT
City of Edmonds PERMIT NUM
Edmonds WA 98020 •
www.edmondswa.gov / 425.1 1
Description: COMCAST - OVERLASH 991' OF FIBER FOR EXPIRED ENG2021-0416
ISSUED: 03/06/2023
Address: 21727 76TH AVE W EDMONDS WA 98026-7549
EXPIRES:09/06/2023
Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 00580700002701
CONTACTS
NAME TYPE NAME ADDRESS PHONE
APPLICANT JESSAMIN SSANTOS 410 VALLEY AVE NW, PUYALLUP WA 98371 (206)401-2188
CONTACT COMCAST 410 VALLEY AVE NW, PUYALLUP WA 98371 (206)401-2188
CONTRACTOR CABLECOM LLC 1316 BONNEVILLE AVE, BLDG A, SNOHOMISH WA 98290 (360)668-1300
OWNER HR ACQUISITION I CORPORATION PO BOX 92129, SOUTH LAKE TX 76092
FEE INFORMATION
DESCRIPTION AMOUNT PAID
CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00
RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $110.00
REQUIREMENTS
REQUIREMENT TYPE NOTES
TRAFFIC CONTROL
Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification
verifying completion of the required training in their posession.
RESTORATION
Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with
asphalt or City approved material prior to the end of the workday - No Exceptions
WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final
inspection and acceptance of the work.
INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM
24 HR NOTICE REQUIRED
INDEMNITY
The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of
any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its
departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney
fees by reason of granting this permit.
94
RELEASED BY: MAJ DATE: 03/06/2023
Printed: Monday, March 06, 2023 1:19:04 PM 1 of 2
RIGHT PERMIT
PERMIT NUM
City of Edmonds
Edmonds WA 98020 •
www.edmondswa.gov / 425.1 1
CONDITIONS
CONDITION TYPE
NOTES
ALERT RESIDENTS
ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START.
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD
ESC REQUIREMENTS
REQUIREMENTS.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to
indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and
agents from any and all claims for damages of whatever nature, arising directly or indirectly from the
HOLD HARMLESS
issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any
requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT.
INSPECTIONS
www.mybuildingpermit.com
POTHOLING
VERIFY CLEAR BORE CROSSINGS.
RESTORE LANDSCAPE
Restore landscape to like or better conditions
Sound or noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on
SOUND AND NOISE
weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites and activities must comply with the noise
limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
INSPECTIONS
INSPECTION TYPE
DATE
RESULT
NOTES
COMPLETE
A-1 JOB START
E-7 TRAFFIC CTRL
X-2 ENGINEERING FINAL"
Printed: Monday, March 06, 2023 1:19:04 PM 2 of 2
of EpM04O�
SECTION A
RIGHT OF WAY CONSTRUCTION
PERMIT APPLICATION
Complete and submit this Application in accordance with the Submittal
Requirements outlined in Right-of-Wgy permit Handout E6�.
RECEIVED
Jan 19 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
If any field is not applicable to your project, write "N/A' instead of leaving blank.
All fields required. Incomplete Applications will be denied.
General •
Project Name JB-8o8498
Site Address or if no site address use Property Address at NW corner of project area: 21727 76TH AVE W, Edmonds, WA 98026
Associated Permits: BLD PLN ENG (RESUBMIT fc
Owner and Entity Holding
Name of Company Comcast Cable Communications Management, LLC. Franchise Ordinance No:
Point of Contact Jessamin Santos
Title Permit Coordinator
Address 410 Valley Ave NW
City Puyallup
State WA
Zip 98371
Phone (2o6) 401-2188
Email jessamin_santos@cable.comcast.com
Contractor and Authorized Agent of Owner
Name of Company Cablecomm, LLC
(see note below)
Contractor Contacts During Construction
Primary Name CHRIS ATKINSON
Agent Name Leah Ihlenfeldt
Title Construction Supervior
Title Permit Coordinator
Mobile 36o-926-3437
Address 1316 BONNEVILLE AVE, BLDG A,
Email CHRIS.ATKINSON@CABLECOMLLC.NET
City Snohomish
State wA
Zip 98290
Secondary Name
Phone (36o) 668-1300
Title
Email leah.ihlenfeldt@cablecomllc.net
Mobile
City of Edmonds Business License No: NR-o21818
Email
State License No: CABLE-971DP
® Contractor verifies it is currently bonded
® Contractor verifies it currently has general liability insurance
NOTE: ECDC 18.6o. o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city
engineer.
❑ Multifamily residential ❑ Commercial ❑ City project
❑ Single family residential subdivision ❑ Single family -other ❑ Industrial
❑ Demo and rebuild or from vacant land?
❑ Other, please specify:
❑ Utility Franchise Work associated with development (check one of the above boxes as welt
❑ Traffic Control Only (no associated development)
X Utility Franchise Work (no associated development)
City of Edmonds ROW construction permit Application --Page 1 Of 3 Updated 3/25/2021
Include an overall narrative description of the proposed work. Be specific and detailed:
Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc.
Include whether this is construction, maintenance, or repair.
Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for
underground utilities, etc.)
Comcast JB- 8o8498: The proposed in the ROW is to overlash up to 991' of 96ct fiber to existing Comcast strand;
along the west side of 76th Ave W, crossing to south side of 218th St SW; proof existing Comcast buried conduit and
Pull 75' of 12ct fiber from riser pole to address 21727 76th Ave W, Edmonds WA 98026. *No disturbance of surface.
REF expired permit# ENG2021-0416
RIGHT-OF-WAY
CLOSURE
AREA
TOTAL
DURATION
(Number of Months)
Sidewalk 72 hours +
LF
x
LF
SF
NA
Alley 72 hours +
LF
x
LF
SF
NA
Parking 72 hours +
LF
x
LF
SF
NA
SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C.
1. The work in the right of way is on or for the following type of facilities:
❑ telecommunications X cable (fiber) ❑ power ❑ gas
❑ water ❑ sewer ❑ storm
Details of Work to be Completed
1. Does the utility owner have existing overhead infrastructure in the area of work?
Yes
X
No
2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)?
X
If yes, describe: New underground 12ct fiber in existing Comcast conduit
3.
Does the proposed work connect a lot or commercial development with utilities that serve more
than one lot or commercial development?
X
4.
Does the work involve rebuilding or relocating an existing aboveground utility system which
connects a lot or commercial development to an existing underground common utility stem?
X
5.
Does the work involve proposed additions to an aboveground utility stem? If es:
X
Are the additions for the purpose of serving new commercial development?
X
Are the additions for the purpose of serving a single-family residential subdivision?
X
Details
of Work to be Completed
Yes
No
6.
Does your project involve rebuilding or replacing utility equipment which currently serves more
than one lot or commercial development?
If yes, answer the following questions related to project area, i.e. the actual area in which the
X
project is proposed:
6a.
Does your project involve wires/cables/lines? If yes:
X
How many are existing? 1 1-2 1How many are to be added? 1
City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021
6b.
Does your project involve poles? If yes:
X
How many poles are existing in the project area?
7
What is the height of the existing Poles? 40 to 50
How many poles are to be removed? 0
Are additional poles to be laced? No
How many? I I What is the height of the additionalpoles?
6c.
Are any poles to be modified/rebuilt/replaced? If yes:
X
How many? I I What is the height of the poles after?
Describe the modification rebuild:
SECTION C
Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as
required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have
certification verifying completion of the required training in their possession.
Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS.
Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to
any permit approval.
Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials,
officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever,
foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or
omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose
acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and
specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any
respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the
expiration, revocation, or termination of any resulting permit approval.
Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and
requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to
the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal
Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable
requirements of state and federal law.
Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a
licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by
owner to act on its behalf and have authority to bind the owner to this application.
Fees. The Applicant is responsible
-7for all permit fees.
APPLICANT SIGNATURE: V essawi4 Saeos
APPLICANT PRINTED NAME: Jessamin Santos
APPLICANT TITLE: Permit Coordinator
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
1/12/2023
City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021
Route Overview
Completed By:
Completion Date:
COMICAST
Survey Revision Date:
Survey Revision Task ID:
Engineered For:
Project Manager:
P2 ID:
Legend
New Ped ❑
Pole
A
New Vault v
Lock Box
Existing U/G
Footage 150'
1
Existing Aerial
Text Box Text
New U/G
1
Callout Arrow
New Aerial
New Tap
Interior Path
Footage Break
Phase Identifier ❑1
Fiber Splice Point
Power Supply Ps
Storage Loop M
w
Hard Surface Cut 0
C
Riser O
Abandoned Cable
Provide Clear Construction Details
1. TIE POINT AT SP.WALY.0239_LY06S.3A.3B.1B.1A
- INSTALL STRAP OUT CASE
- 155' ROW AERIAL 96C FOC DELASH / RELASH
- 149' ROW AERIAL 96C FOC DELASH / RELASH
- 136' ROW AERIAL 96C FOC DELASH / RELASH
(FLYING DUTCHMAN)
- 6' ROW AERIAL 96C FOC DELASH / RELASH
- 219' ROW AERIAL 96C FOC DELASH / RELASH
(FLYING DUTCHMAN)
- 151' ROW AERIAL 96C FOC OVERLASH
- 175' ROW AERIAL 96C FOC OVERLASH
- INSTALL ENCLOSURE TO TRANSITION 96C
TO 12C FOC
2. 25' ROW RISER 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- 75' ROW TO PRIVATE 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- 70' ROW TO PRIVATE 12C FOC CONDUIT PULL
CONDUIT(EXISTING 2" PULL) - PULL INTO EXISTING EXTERIOR LOCKBOXRECEIVE
***ROUTE OVERVIEW CONTINUED ON TAB (2)*** Jan 19 2023
CITY OF EDMONDS
DEVELOPMENT SERVICE:
DEPARTMENT
W.PASCHAL
10/12/2021 Address: 21727 76TH AVE W, EDMONDS, WA 98026
Footages Entered On Right of Way, Private Exterior, and Private Interior tabs. Footages
are summarized on Survey Rollup tab.
W
E
`s
Are Additional Pages Needed:
No
JB0000808498
10' V FROM ELECTRICAL ROOM TO 1ST FLOOR 21IN ELECTRICAL ROOM
F.A.C.P. ROOM (1ST FLOOR) THRU CHASEWAY 4 (SUB -LEVEL PARKING)
A C
8 [•►
8' FROM CHASEWAY - DOWN WALL IN
4 24'
F.A.C.P. ROOM - INSTALL (IM) ON WALL 3
wd_ ,
81'
38' IN F.A.C.P. ROOM THRU CEILING
_
-
VOIDS INTO STE C ABOVE IDF 5
70'
219'
5
1 6' 5NtMrp111.&01
2
• 151' 9' IN STE CIS IDF
CLOSET - INSTALL
75'
1
EQUIPMENT ON WALL
FLYING
i
DUTCHMAN
136' 1 175'
25' R
1
INSTALL ENCLOSURE TO
TRANSITION 96C TO 12C FOC
WASNEM001
ENGINEERING DIVISION
:rC�ti -iA V't8 to 149' rw.11iWM+r
"'7TED
_ 13/06/2022
Uv
Applicant shall repair/replace all
TIE POINT @
_
damage to utilities or frontage
improvements in City right-of-way
SP. WALY.0239
per city statndards that icaused or
occurs during he permitted project.
LY06S.3A.36.18.1A
"' t
INSTALL STI
A
OWNER/CONTRACTOR IS RESPONSIBLE FOR
OUT CASE
EROSION CONTROL AND DRAINAGE
StiFYtbIDADt t
155'
OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
.i UTILITIES MAY REQUIRE A SEPERATE PERMIT.
AA 04 1V If, Q111t4In
i I
�.�. 0 ft
Route Overview
d1�
COMICAST
Legend
New Ped ❑
Pole
New Vault ❑V
Lock Box
Existing U/G
Footage
Existing Aerial
Text Box
New U/G
Callout Arrow
New Aerial
New Tap
Interior Path
Footage Break
Phase Identifier
Power Su I
Completed By:
Completion Date:
Survey Revision Date:
Survey Revision Task ID:
Engineered For:
Project Manager:
P2 ID:
0
Fiber Splice Point pP y ns
Storage Loop CD
Hard Surface Cut 0
C
Riser O Abandoned Cable
Provide Clear Construction Details
3. 81' PRIVATE EXT 12C FOC THRU DROP PANEL
CEILING VOID IN SUB -LEVEL PARKING GARAGE
- INSTALL SPLIT DUCT
- 24' PRIVATE EXT 12C FOC THRU DROP PANEL
CEILING VOID IN SUB -LEVEL PARKING GARAGE
- INSTALL SPLIT DUCT
- POE DRILL THRU CINDER BLOCK WALL / DRYWALL
INTO ELECTRICAL ROOM
4. 21' PRIVATE INT 12C FOC IN ELCTRICAL ROOM
INTO CHASEWAY.
- 10' V PRIVATE INT 12C FOC IN CHASEWAY TO
1ST FLOOR F.A.C.P. ROOM
- CUT ACCESS IN CHASEWAY DRYWALL INTO
F.A.C.P. ROOM
- 8' PRIVATE INT 12C FOC IN F.A.C.P AND INSTALL
(IM) ON WALL AT EXISTING LOCKBOX WITH RF
5. 38' PRIVATE INT 12C FOC FROM F.A.C.P. THRU
CHASEWAY AND DROP PANEL CEILING VOID
- INTO STE C AT IDF CLOSET
-9' PRIVATE INT 12C FOC IN IDF CLOSET RECEIVED
- INSTALL EQUIPMENT ON WALL
- AVAILABLE 110 VAC ON WALL Jan 19 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
W.PASCHAL
10/12/2021 Address: 21727 76TH AVE W, EDMONDS, WA 98026
Footages Entered On Right of Way, Private Exterior, and Private Interior tabs. Footages
are summarized on Survey Rollup tab.
JB0000808498 Are Additional Pages Needed: No I
10' V FROM ELECTRICAL ROOM TO 1ST FLOOR 21' IN ELECTRICAL ROOM
F.A.C.P. ROOM (1ST FLOOR) THRU CHASEWAY 4 (SUB -LEVEL PARKING)
g p 8' FROM CHASEWAY - DOWN WALL IN 4 24'
F.A.C.P. ROOM - INSTALL (IM) ON WALL 3
I�IALY $1'
'IN F.A.C.P. ROOM THRU CEILING
VOIDS INTO STE C ABOVE IDF 5
W
S
E
70' 2
219' L' yNtwit 11.At, I'k5
151' 9' IN STE C'S IDF 75'
1 1 CLOSET - INSTALL
FLYING EQUIPMENT ON WALL
DUTCHMAN 136' 1 175' 1 25' R
INSTALL ENCLOSURE TO 'r
TRANSITION 96C TO 12C FOC
WASNEM001
SP VIAL r 0139
;YC65'?A'T8�1[! to 14T NANiE1M��r ,�
Y7
TIE POINT @
SP.WALY.0239 = _
LY06S.3A.3B.1B.1A
INSTALL STRAP 1
OUT CASE
SAE11✓i!DA5t 4
155'
AAMI/Aw/ M ftN � 1 � 1 A
eo R /
Right of Way
COMCAST
Completed By:
Completion Date:
Survey Revision Date:
Survey Revision Task ID:
Engineered For:
Project Manager:
P2 ID:
Legend
New Ped ❑
Pole
New Vault ❑V
Lock Box
Existing U/G
Footage
150'
Existing Aerial
Text Box
Text
New U/G
Callout Arrow
New Aerial
New Tap
Interior Path
Footage Break
Phase Identifier
❑1
Fiber Splice Point
Power Supply
Ps
Storage Loop M
w
Hard Surface Cut
C
0
Riser O
Abandoned Cable
Provide Clear Construction Details
1. TIE POINT AT SP.WA1LY.0239_1LY06S.3A.3B.1B.1A
- INSTALL STRAP OUT CASE
- 155' ROW AERIAL 96C FOC DELASH / RELASH
- 149' ROW AERIAL 96C FOC DELASH / RELASH
- 136' ROW AERIAL 96C FOC DELASH / RELASH
(FLYING DUTCHMAN)
- 6' ROW AERIAL 96C FOC DELASH / RELASH
- 219' ROW AERIAL 96C FOC DELASH / RELASH
(FLYING DUTCHMAN)
- 151' ROW AERIAL 96C FOC OVERLASH
- 175' ROW AERIAL 96C FOC OVERLASH
- INSTALL ENCLOSURE TO TRANSITION 96C
TO 12C FOC
2. 25' ROW RISER 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- 75' ROW TO PRIVATE 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- 70' ROW TO PRIVATE 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- PULL INTO EXISTING EXTERIOR LOCKBOX
RECEIVED
Jan 19 2023
CITY OF
EDMONDS F -
DEVELOPMENT SERVICES
DEPARTMENT
r
W.PASCHAL
10/ 12/2021
INSTALL STRAP
OUT CASE
155'
1
Address: 21727 76TH AVE W, EDMONDS, WA 98026
Right of Way Footages:
New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 75
New Aerial Fiber: Overlash Fiber: 0 Existing UG Fiber: 0
Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0
Are Additional Pages Needed:
TIE POINT @
SP.WALY.0239
LY06S.3A.36.18.1A
=0
INSTALL SNAP
OU I CASE
I5S
TIE POINT @ '
SP.WALY.0239 1S5'
LY06S.3A.36.1B.1A -� ' .
JJ 11 . I
149' j 136'
TIE POINT @
SP.WALY.0239
1 LY06S.3A.36.16.1A
1-01
TIE POINT @
SP.WALY.0239
LY06S.3A.3B.16.1A
INSTALL STRAP
OUT CASE
1
149'
FLYING
DUTCHMAN
136'M61-
"6'
Right of Way
COMICAST
Completed By: W. PASCHAL
Completion Date: 10/12/2021
Survey Revision Date:
Survey Revision Task ID:
Engineered For:
Project Manager: -
P21D: JB0000808498
ti
Legend - }
New Ped ❑ Pole
New Vault ❑V Lock Box 149,
Existing U/G Footage 150'
Existing Aerial
Text Box Text
New U/G 136
Callout Arrow '
New Aerial A
New Tap
Interior Path
Footage Break Phase Identifier
Fiber Splice Point Power Supply Ps
Storage Loop CD
Hard Surface Cut 0
C
Riser O Abandoned Cable
Provide Clear Construction Details
1. TIE POINT AT SP.WALY.0239_LY06S.3A.313.113.1A
- INSTALL STRAP OUT CASE
- 155' ROW AERIAL 96C FOC DELASH / RELASH
- 149' ROW AERIAL 96C FOC DELASH / RELASH
- 136' ROW AERIAL 96C FOC DELASH / RELASH
(FLYING DUTCHMAN)
- 6' ROW AERIAL 96C FOC DELASH / RELASH
- 219' ROW AERIAL 96C FOC DELASH / RELASH
(FLYING DUTCHMAN)
- 151' ROW AERIAL 96C FOC OVERLASH
- 175' ROW AERIAL 96C FOC OVERLASH
- INSTALL ENCLOSURE TO TRANSITION 96C
TO 12C FOC
2. 25' ROW RISER 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- 75' ROW TO PRIVATE 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- 70' ROW TO PRIVATE 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- PULL INTO EXISTING EXTERIOR LOCKBOX
RECEIVED
Jan 19 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
J
136'
219'
Address:
New Aerial Coax: 0
New Aerial Fiber: 991
Empty Conduit Only: 0
Are Additional Pages Needed:
. YA
FLYING
DUTCHMAN ,
219' 6'
►.
FLYING
DUTCHMAN
-..
15 1' LA.
21727 76TH AVE W, EDMONDS, WA 98026
Right of Way Footages:
Overlash Coax: 0 New UG Fiber:
Overlash Fiber: 0 Existing UG Fiber:
New UG Coax: 0 Existing UG Coax:
No
FLYING
DUTCHMAN
219'
..
O
n
FLYING
DUTCHMAN
1
N-1
Right of Way
COMCAST
Completed By:
Completion Date:
Survey Revision Date:
Survey Revision Task ID:
Engineered For:
Project Manager:
P2 ID:
Legend
New Ped ❑
Pole
New Vault ❑V
Lock Box
Existing U/G
Footage
150'
Existing Aerial
Text Box
Text
New U/G
Callout Arrow
New Aerial
New Tap
Interior Path
Footage Break
Phase Identifier
❑1
Fiber Splice Point
Power Supply
Ps
Storage Loop CD
Hard Surface Cut
O
Riser (D
Abandoned Cable
Provide Clear Construction Details
1. TIE POINT AT SP.WALY.0239_LY06S.3A.3B.1B.1A
- INSTALL STRAP OUT CASE
- 155' ROW AERIAL 96C FOC DELASH / RELASH
- 149' ROW AERIAL 96C FOC DELASH / RELASH
- 136' ROW AERIAL 96C FOC DELASH / RELASH
(FLYING DUTCHMAN)
- 6' ROW AERIAL 96C FOC DELASH / RELASH
- 219' ROW AERIAL 96C FOC DELASH / RELASH
(FLYING DUTCHMAN)
- 151' ROW AERIAL 96C FOC OVERLASH
- 175' ROW AERIAL 96C FOC OVERLASH
- INSTALL ENCLOSURE TO TRANSITION 96C
TO 12C FOC
2. 25' ROW RISER 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- 75' ROW TO PRIVATE 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- 70' ROW TO PRIVATE 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- PULL INTO EXISTING EXTERIOR LOCKBOX
RECEIVED
Jan
19 2023
CITY OF EDMONDS
DEVELOPMENT
SERVICES
DEPARTMENT
L,219'
n
6'
W. PASCHAL Address:
10/ 12/2021
New Aerial Coax: 0
New Aerial Fiber: 991
Empty Conduit Only: 0
JB0000808498 Are Additional Pages Needed:
• FLYING
DUTCHMAN
1k136'..
„
151'
21727 76TH AVE W, EDMONDS, WA 98026
Right of Way Footages:
Overlash Coax: 0 New UG Fiber:
Overlash Fiber: 0 Existing UG Fiber:
New UG Coax: 0 Existing UG Coax:
No
INSTALL ENCLOSURE TO
TRANSITION 96C TO 12C FOC
175'
1
Y . >t INSTALL ENCLOSURE TO 1751
TRANSITION 96C TO 12C FOC
1
.0 -
Right of Way
COMCAST
Legend
New Ped ❑
Pole
New Vault ❑V
Lock Box
Existing U/G
Footage
Existing Aerial
Text Box
New U/G
Callout Arrow
New Aerial
New Tap
Interior Path
Footage Break
Phase Identifier
Power Su I
Completed By:
Completion Date:
Survey Revision Date:
Survey Revision Task ID:
Engineered For:
Project Manager:
P2 ID:
150'
Text
❑1
Fiber Splice Point pp y Ps
Storage Loop CD Hard Surface Cut 0
Riser OAbandoned Cable
Provide Clear Construction Details
1. TIE POINT AT SP.WALY.0239_LY06S.3A.3B.1 B.1A
- INSTALL STRAP OUT CASE
- 155' ROW AERIAL 96C FOC DELASH / RELASH
- 149' ROW AERIAL 96C FOC DELASH / RELASH
W.PASCHAL
10/ 12/2021
Address:
New Aerial Coax:
New Aerial Fiber:
Empty Conduit Only
21727 76TH AVE W, EDMONDS, WA 98026
Right of Way Footages:
0 Overlash Coax: 0 New UG Fiber:
991 Overlash Fiber: 0 Existing UG Fiber:
0 New UG Coax: 0 Existing UG Coax:
JB0000808498 Are Additional Pages Needed:
INSTALL ENCLOSURE TO
TRANSITION 96C TO 12C FOC
175' 1 --•
- 136' ROW AERIAL 96C FOC DELASH / RELASH
(FLYING DUTCHMAN) ", .►`
- 6' ROW AERIAL 96C FOC DELASH / RELASH
- 219' ROW AERIAL 96C FOC DELASH / RELASH *.,Apr
a
(FLYING DUTCHMAN) �.' : „
- 151' ROW AERIAL 96C FOC OVERLASH
- 175' ROW AERIAL 96C FOC OVERLASH ~ ��' •
-INSTALL ENCLOSURE TO TRANSITION 96C
TO 12C FOC •
2. 25' ROW RISER 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- 75' ROW TO PRIVATE 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- 70' ROW TO PRIVATE 12C FOC CONDUIT PULL
(EXISTING 2" CONDUIT - PROOF AND PULL)
- PULL INTO EXISTING EXTERIOR LOCKBOX
3. 81' PRIVATE EXT 12C FOC THRU DROP PANEL
CEILING VOID IN SUB -LEVEL PARKING GARAGE
- INSTALL SPLIT DUCT RECEIVED
Jan 19 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT y
25' R
75'
10
' :+'+ •;
No
t
0
2
ry
3 A
to A
00
00 ON
TRAFFIC CONTROL INSPECTION SHALL BE
REQUIRED WHENEVER WORK ZONE IS SET UP MAINTAIN TWO 11' TRAVEL LANES
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
70
LENGTH (feet)
155
200
250
305
360
425
495
570
645
730
TMA ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 lbs.
HOST VEHICLE WEIGHT
> 22,000 lbs.
c 45 MPH
1 45-55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100'
1 123'
172'
74'
100,
150,
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
MINIMUM TAPER LENGTH = L (feet)
Lane
Width (feet)
Posted Speed (mph)
25 30 35 40 45 50 55 60 65 70
10
105
150
1 205
1 270
1 450
1 500
1 550
-
-
-
11
115
165
225
295
495
550
605
660
-
-
12
125
180
1 245
1 320
1 540
1 600
Spotter to assist pedestrians
through work zone
SIGN SPACING = X (FEET) ( 1 )
RURAL HIGHWAYS 60165 MPH
8001±
RURAL ROADS 45/55 MPH
500'±
RURAL ROADS & URBAN ARTERIALS 35/40 MPH
350'±
RURAL ROADS, URBAN ARTERIALS 25/30 MPH
RESIDENTIAL & BUSINESS DISTRICTS
200'± (2)
URBAN STREETS 25 MPH OR LESS
ALL SIGNS ARE 48" X 48" BLACK ON ORANGE UNLESS OTHERWISE
DESIGNATED.
(1) All spacing may be adjusted to accommodate interchange
ramps, at -grade intersections, and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
CHANNELIZING DEVICE SPACING (FEET)
W1 4L
R4-7B KEEP
W20 1 ROAD
ER TAN MPH TAPER
24" X 30" 10*
WORK
50/60 40 80
B/W 00
RIGHT
AHEAD
35/45 30 60
25130 20 40
30' MIN.
20' 100' MAX. R B L/2 X
X
FOR TMA
0
q
q
° 63 WORK AREA ® °
gon 0❑ 0 Z
00 ® ° 2ft min. recommended o IT]°
�_
o a❑
—°oi�00000000000000000000° — —
—
_ _
a a
�
X X
L/2 L/2 DEVICE SPACING 1/2 DISTANCE SPACING 1/2 DISTANCE FOR
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or tCAHEAD
occurs during the permitted project.
W
LEGEND
IN SIGN LOCATION
® SIGN LOCATION - S MOUNTING W20-5L
HEIGHT -RECOMMENDED
0 0 0 CHANNELIZING DEVICES
EM PROTECTIVE VEHICLE REQUIRED
OWNER/CONTRACTOR IS RESPONSIBLE FOR
EROSION CONTROLAND DRAINAGE
OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
UTILITIES MAY REQUIRE A SEPERATE PERMIT.
OPPOSING TRAFFIC DEVICES
NOTES
1. For long term projects, conflicting pavement markings no longer
applicable must be removed or obliterated as soon as practicable.
Temporary markings shall be used as necessary and signs shall
be post mounted.
2. For speed limits of 30 mph or less, use sign W1-3 in lieu of sign W14.
3. Extend device taper across shoulder if applicable.
4. Protective vehicle with TMA required for roadways 45 mph or higher.
For roads 40 mph or less - shall be a work vehicle placed strategically
to shield work area.
0
0
IV
TYPICAL LANE SHIFT WITH TWO WAY LEFT TURN LANE TCP 22 RECEIVED
ENGINEERING DIVISION Jan 19 2023
.„)TED
CITY OF EDMONDS
DEVELOPMENT SERVICES
Ilf'h"1� 13/06/2022 DEPARTMENT
ONE LANE ROAD
AHEAD
WORK ZONE CONDITION (SEE CHAPTER 1.9.10)
ROAD '
A - ALLOWED - CONSIDER USING A SPOTTER. N0R
AXFAD
B - ALLOWED - SPOTTER RECOMMENDED o_<
CONSIDER ADDITIONAL WARNING SIGNS.PREPARED
De
os P
C - NOT ALLOWED - SEE TCP 14 & 15 FOR
ADDITIONAL WORK ZONE REQUIREMENTS. O
Flaggers to maintain one lane of traffic at all
times for overlash work crossing 218th St SW
& 76th Ave W.
00
N
TRAFFIC CONTROL INSPECTION SHALL BE
REQUIRED WHENEVER WORK ZONE IS SET UP
--------- ¢ WORK
AREA
ROAD W BE
WORK PREPARED D
AXEAD TO STOP L■n
\/
ONE LANE ROAD
AHEAD
Spotter to assist pedestrians through work zone
LEGEND
WORK VEHICLE W/ WARNING BEACON
I� (LOCATE TO SHIELD WORK VEHICL6
OS SPOTTER NE LANE ROAD
AHEAD
SIGHT DISTANCE DATA
MINIMUM STOPPING SIGHT DISTANCE = S
SPEED LIMIT
25
30
35
40
45
50
55
60
65
70
MPH
DISTANCE
FEET
155
200
250
305
360
425
495
570
645
730
DISTANCES SHOWN ARE MINIMUMS, USE ADDITIONAL DISTANCE WHEN POSSIBLE.
n
to
0
L
G
CD
ONE LANE ROA@
GENERAL LIMITS OF AHEAD 0
CHANNELIZED INTERSECTION
i o
BE
5 0OM<(�>,
�
C
------------------------
O
CD
sv
o'
�rt
CD
cn
CD
.._ .
r� NOTES: �
1. Work vehicle w/beacon located in same quadrant as -0
BED work location.
PREPARED ^
D R "P 2. Repeated access to work lane not allowed. see tcp
14 & 15 for work zone requirements - condition "C1 S.
3. Restricted sight distance requires additional advance
warning devices or signs, see sight distance data chart.
4. Recommend working during red phase if signalized.
5. See chapter 1.9.10 - 1.9.11 for additional direction .
TYPICAL VERY SHORT DURATION WORK OPERATION "ROAD WORK AHEAD" signs to be
(INTERSECTION APPLICATION) placed On all public road approaches to
TCP 29 work area Or advance sign area. RECEIVED
Jan 19 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
X
C)
C
SIGN SPACING = X (FEET) ( 1 )
RURAL HIGHWAYS 60 / 65 MPH
8001t
RURAL ROADS 45 / 55 MPH
5001t
RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH
3501t
RURAL ROADS, URBAN ARTERIALS 25 / 30 MPH
RESIDENTIAL & BUSINESS DISTRICTS
200't (2)
URBAN STREETS 25 MPH OR LESS
1001t (2)
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE
DESIGNATED.
(1) All spacing may be adjusted to accommodate intersections
and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
A A
so SO'R
i
OAP ®®®
SOP + 2
+ w20-7A
BE
PREPARED
�� + TO STOP w20-713
(OPTIONAL IF 40 MPH OR LESS)
ROAD
WORK
AHEAD
M0-1
LEGEND
FLAGGING STATION
DI
SIGN LOCATION
®®®
CHANNELIZING DEVICES
PROTECTIVE VEHICLE
w
W20-7A
n
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
10
LENGTH (feet)
155
200
250
305
360
425
495
570
645
730
TMA ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 Ibs.
HOST VEHICLE WEIGHT
> 22,000 Ibs.
< 45 MPH
45-55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100'
1 123'
172'
74'
100'
150'
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
CHANNELIZING DEVICE SPACING (FEET)
MPH
TAPER
TANGENT
50165 65
40
80
35 / 45
30
60
25/30
20
40
W20JB
(OPTIONAL IF 40 MPH OR LESS)
BE
PREPARED
,TD STEP // \\ W20-4
ONE LANE
ROAD
AHEAD 5-1
ROAD
WORK
\'r AHEAD
ONE LANE
ROAD NOTES
AHEAD
W20-4 1. Night work requires additional roadway lighting at flagging stations.
2. Recommend extending channelizing device taper across shoulder. Channelizing devices
at flagger stations recommended.
3. Protective vehicle - may be a work vehicle strategically located to shield the work area.
4. For low -volume situations with short work zones on straight roadways where the flagger is visible
to road users approaching from both directions, a single flagger, positioned to be visible from both
directions may a used.
5. Extend the longitudinal buffer space to locate the taper in advance of a curve, if necessary.
TYPICAL ONE -LANE, TWO-WAY TRAFFIC CONTROL WITH FLAGGERS TCP 1 RECEIVED
Jan 19 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT