Loading...
ENG2023-0018 ROW PERMITRIGHT PERMIT City of Edmonds PERMIT NUM Edmonds WA 98020 • www.edmondswa.gov / 425.1 1 Description: COMCAST - OVERLASH 991' OF FIBER FOR EXPIRED ENG2021-0416 ISSUED: 03/06/2023 Address: 21727 76TH AVE W EDMONDS WA 98026-7549 EXPIRES:09/06/2023 Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 00580700002701 CONTACTS NAME TYPE NAME ADDRESS PHONE APPLICANT JESSAMIN SSANTOS 410 VALLEY AVE NW, PUYALLUP WA 98371 (206)401-2188 CONTACT COMCAST 410 VALLEY AVE NW, PUYALLUP WA 98371 (206)401-2188 CONTRACTOR CABLECOM LLC 1316 BONNEVILLE AVE, BLDG A, SNOHOMISH WA 98290 (360)668-1300 OWNER HR ACQUISITION I CORPORATION PO BOX 92129, SOUTH LAKE TX 76092 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00 RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $110.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. 94 RELEASED BY: MAJ DATE: 03/06/2023 Printed: Monday, March 06, 2023 1:19:04 PM 1 of 2 RIGHT PERMIT PERMIT NUM City of Edmonds Edmonds WA 98020 • www.edmondswa.gov / 425.1 1 CONDITIONS CONDITION TYPE NOTES ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on SOUND AND NOISE weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT NOTES COMPLETE A-1 JOB START E-7 TRAFFIC CTRL X-2 ENGINEERING FINAL" Printed: Monday, March 06, 2023 1:19:04 PM 2 of 2 of EpM04O� SECTION A RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal Requirements outlined in Right-of-Wgy permit Handout E6�. RECEIVED Jan 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A' instead of leaving blank. All fields required. Incomplete Applications will be denied. General • Project Name JB-8o8498 Site Address or if no site address use Property Address at NW corner of project area: 21727 76TH AVE W, Edmonds, WA 98026 Associated Permits: BLD PLN ENG (RESUBMIT fc Owner and Entity Holding Name of Company Comcast Cable Communications Management, LLC. Franchise Ordinance No: Point of Contact Jessamin Santos Title Permit Coordinator Address 410 Valley Ave NW City Puyallup State WA Zip 98371 Phone (2o6) 401-2188 Email jessamin_santos@cable.comcast.com Contractor and Authorized Agent of Owner Name of Company Cablecomm, LLC (see note below) Contractor Contacts During Construction Primary Name CHRIS ATKINSON Agent Name Leah Ihlenfeldt Title Construction Supervior Title Permit Coordinator Mobile 36o-926-3437 Address 1316 BONNEVILLE AVE, BLDG A, Email CHRIS.ATKINSON@CABLECOMLLC.NET City Snohomish State wA Zip 98290 Secondary Name Phone (36o) 668-1300 Title Email leah.ihlenfeldt@cablecomllc.net Mobile City of Edmonds Business License No: NR-o21818 Email State License No: CABLE-971DP ® Contractor verifies it is currently bonded ® Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o. o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as welt ❑ Traffic Control Only (no associated development) X Utility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page 1 Of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Comcast JB- 8o8498: The proposed in the ROW is to overlash up to 991' of 96ct fiber to existing Comcast strand; along the west side of 76th Ave W, crossing to south side of 218th St SW; proof existing Comcast buried conduit and Pull 75' of 12ct fiber from riser pole to address 21727 76th Ave W, Edmonds WA 98026. *No disturbance of surface. REF expired permit# ENG2021-0416 RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF x LF SF NA Alley 72 hours + LF x LF SF NA Parking 72 hours + LF x LF SF NA SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications X cable (fiber) ❑ power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existing overhead infrastructure in the area of work? Yes X No 2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)? X If yes, describe: New underground 12ct fiber in existing Comcast conduit 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility stem? X 5. Does the work involve proposed additions to an aboveground utility stem? If es: X Are the additions for the purpose of serving new commercial development? X Are the additions for the purpose of serving a single-family residential subdivision? X Details of Work to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? If yes, answer the following questions related to project area, i.e. the actual area in which the X project is proposed: 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? 1 1-2 1How many are to be added? 1 City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? 7 What is the height of the existing Poles? 40 to 50 How many poles are to be removed? 0 Are additional poles to be laced? No How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? I I What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible -7for all permit fees. APPLICANT SIGNATURE: V essawi4 Saeos APPLICANT PRINTED NAME: Jessamin Santos APPLICANT TITLE: Permit Coordinator NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE 1/12/2023 City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 Route Overview Completed By: Completion Date: COMICAST Survey Revision Date: Survey Revision Task ID: Engineered For: Project Manager: P2 ID: Legend New Ped ❑ Pole A New Vault v Lock Box Existing U/G Footage 150' 1 Existing Aerial Text Box Text New U/G 1 Callout Arrow New Aerial New Tap Interior Path Footage Break Phase Identifier ❑1 Fiber Splice Point Power Supply Ps Storage Loop M w Hard Surface Cut 0 C Riser O Abandoned Cable Provide Clear Construction Details 1. TIE POINT AT SP.WALY.0239_LY06S.3A.3B.1B.1A - INSTALL STRAP OUT CASE - 155' ROW AERIAL 96C FOC DELASH / RELASH - 149' ROW AERIAL 96C FOC DELASH / RELASH - 136' ROW AERIAL 96C FOC DELASH / RELASH (FLYING DUTCHMAN) - 6' ROW AERIAL 96C FOC DELASH / RELASH - 219' ROW AERIAL 96C FOC DELASH / RELASH (FLYING DUTCHMAN) - 151' ROW AERIAL 96C FOC OVERLASH - 175' ROW AERIAL 96C FOC OVERLASH - INSTALL ENCLOSURE TO TRANSITION 96C TO 12C FOC 2. 25' ROW RISER 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - 75' ROW TO PRIVATE 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - 70' ROW TO PRIVATE 12C FOC CONDUIT PULL CONDUIT(EXISTING 2" PULL) - PULL INTO EXISTING EXTERIOR LOCKBOXRECEIVE ***ROUTE OVERVIEW CONTINUED ON TAB (2)*** Jan 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICE: DEPARTMENT W.PASCHAL 10/12/2021 Address: 21727 76TH AVE W, EDMONDS, WA 98026 Footages Entered On Right of Way, Private Exterior, and Private Interior tabs. Footages are summarized on Survey Rollup tab. W E `s Are Additional Pages Needed: No JB0000808498 10' V FROM ELECTRICAL ROOM TO 1ST FLOOR 21IN ELECTRICAL ROOM F.A.C.P. ROOM (1ST FLOOR) THRU CHASEWAY 4 (SUB -LEVEL PARKING) A C 8 [•► 8' FROM CHASEWAY - DOWN WALL IN 4 24' F.A.C.P. ROOM - INSTALL (IM) ON WALL 3 wd_ , 81' 38' IN F.A.C.P. ROOM THRU CEILING _ - VOIDS INTO STE C ABOVE IDF 5 70' 219' 5 1 6' 5NtMrp111.&01 2 • 151' 9' IN STE CIS IDF CLOSET - INSTALL 75' 1 EQUIPMENT ON WALL FLYING i DUTCHMAN 136' 1 175' 25' R 1 INSTALL ENCLOSURE TO TRANSITION 96C TO 12C FOC WASNEM001 ENGINEERING DIVISION :rC�ti -iA V't8 to 149' rw.11iWM+r "'7TED _ 13/06/2022 Uv Applicant shall repair/replace all TIE POINT @ _ damage to utilities or frontage improvements in City right-of-way SP. WALY.0239 per city statndards that icaused or occurs during he permitted project. LY06S.3A.36.18.1A "' t INSTALL STI A OWNER/CONTRACTOR IS RESPONSIBLE FOR OUT CASE EROSION CONTROL AND DRAINAGE StiFYtbIDADt t 155' OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY .i UTILITIES MAY REQUIRE A SEPERATE PERMIT. AA 04 1V If, Q111t4In i I �.�. 0 ft Route Overview d1� COMICAST Legend New Ped ❑ Pole New Vault ❑V Lock Box Existing U/G Footage Existing Aerial Text Box New U/G Callout Arrow New Aerial New Tap Interior Path Footage Break Phase Identifier Power Su I Completed By: Completion Date: Survey Revision Date: Survey Revision Task ID: Engineered For: Project Manager: P2 ID: 0 Fiber Splice Point pP y ns Storage Loop CD Hard Surface Cut 0 C Riser O Abandoned Cable Provide Clear Construction Details 3. 81' PRIVATE EXT 12C FOC THRU DROP PANEL CEILING VOID IN SUB -LEVEL PARKING GARAGE - INSTALL SPLIT DUCT - 24' PRIVATE EXT 12C FOC THRU DROP PANEL CEILING VOID IN SUB -LEVEL PARKING GARAGE - INSTALL SPLIT DUCT - POE DRILL THRU CINDER BLOCK WALL / DRYWALL INTO ELECTRICAL ROOM 4. 21' PRIVATE INT 12C FOC IN ELCTRICAL ROOM INTO CHASEWAY. - 10' V PRIVATE INT 12C FOC IN CHASEWAY TO 1ST FLOOR F.A.C.P. ROOM - CUT ACCESS IN CHASEWAY DRYWALL INTO F.A.C.P. ROOM - 8' PRIVATE INT 12C FOC IN F.A.C.P AND INSTALL (IM) ON WALL AT EXISTING LOCKBOX WITH RF 5. 38' PRIVATE INT 12C FOC FROM F.A.C.P. THRU CHASEWAY AND DROP PANEL CEILING VOID - INTO STE C AT IDF CLOSET -9' PRIVATE INT 12C FOC IN IDF CLOSET RECEIVED - INSTALL EQUIPMENT ON WALL - AVAILABLE 110 VAC ON WALL Jan 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W.PASCHAL 10/12/2021 Address: 21727 76TH AVE W, EDMONDS, WA 98026 Footages Entered On Right of Way, Private Exterior, and Private Interior tabs. Footages are summarized on Survey Rollup tab. JB0000808498 Are Additional Pages Needed: No I 10' V FROM ELECTRICAL ROOM TO 1ST FLOOR 21' IN ELECTRICAL ROOM F.A.C.P. ROOM (1ST FLOOR) THRU CHASEWAY 4 (SUB -LEVEL PARKING) g p 8' FROM CHASEWAY - DOWN WALL IN 4 24' F.A.C.P. ROOM - INSTALL (IM) ON WALL 3 I�IALY $1' 'IN F.A.C.P. ROOM THRU CEILING VOIDS INTO STE C ABOVE IDF 5 W S E 70' 2 219' L' yNtwit 11.At, I'k5 151' 9' IN STE C'S IDF 75' 1 1 CLOSET - INSTALL FLYING EQUIPMENT ON WALL DUTCHMAN 136' 1 175' 1 25' R INSTALL ENCLOSURE TO 'r TRANSITION 96C TO 12C FOC WASNEM001 SP VIAL r 0139 ;YC65'?A'T8�1[! to 14T NANiE1M��r ,� Y7 TIE POINT @ SP.WALY.0239 = _ LY06S.3A.3B.1B.1A INSTALL STRAP 1 OUT CASE SAE11✓i!DA5t 4 155' AAMI/Aw/ M ftN � 1 � 1 A eo R / Right of Way COMCAST Completed By: Completion Date: Survey Revision Date: Survey Revision Task ID: Engineered For: Project Manager: P2 ID: Legend New Ped ❑ Pole New Vault ❑V Lock Box Existing U/G Footage 150' Existing Aerial Text Box Text New U/G Callout Arrow New Aerial New Tap Interior Path Footage Break Phase Identifier ❑1 Fiber Splice Point Power Supply Ps Storage Loop M w Hard Surface Cut C 0 Riser O Abandoned Cable Provide Clear Construction Details 1. TIE POINT AT SP.WA1LY.0239_1LY06S.3A.3B.1B.1A - INSTALL STRAP OUT CASE - 155' ROW AERIAL 96C FOC DELASH / RELASH - 149' ROW AERIAL 96C FOC DELASH / RELASH - 136' ROW AERIAL 96C FOC DELASH / RELASH (FLYING DUTCHMAN) - 6' ROW AERIAL 96C FOC DELASH / RELASH - 219' ROW AERIAL 96C FOC DELASH / RELASH (FLYING DUTCHMAN) - 151' ROW AERIAL 96C FOC OVERLASH - 175' ROW AERIAL 96C FOC OVERLASH - INSTALL ENCLOSURE TO TRANSITION 96C TO 12C FOC 2. 25' ROW RISER 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - 75' ROW TO PRIVATE 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - 70' ROW TO PRIVATE 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - PULL INTO EXISTING EXTERIOR LOCKBOX RECEIVED Jan 19 2023 CITY OF EDMONDS F - DEVELOPMENT SERVICES DEPARTMENT r W.PASCHAL 10/ 12/2021 INSTALL STRAP OUT CASE 155' 1 Address: 21727 76TH AVE W, EDMONDS, WA 98026 Right of Way Footages: New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 75 New Aerial Fiber: Overlash Fiber: 0 Existing UG Fiber: 0 Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 Are Additional Pages Needed: TIE POINT @ SP.WALY.0239 LY06S.3A.36.18.1A =0 INSTALL SNAP OU I CASE I5S TIE POINT @ ' SP.WALY.0239 1S5' LY06S.3A.36.1B.1A -� ' . JJ 11 . I 149' j 136' TIE POINT @ SP.WALY.0239 1 LY06S.3A.36.16.1A 1-01 TIE POINT @ SP.WALY.0239 LY06S.3A.3B.16.1A INSTALL STRAP OUT CASE 1 149' FLYING DUTCHMAN 136'M61- "6' Right of Way COMICAST Completed By: W. PASCHAL Completion Date: 10/12/2021 Survey Revision Date: Survey Revision Task ID: Engineered For: Project Manager: - P21D: JB0000808498 ti Legend - } New Ped ❑ Pole New Vault ❑V Lock Box 149, Existing U/G Footage 150' Existing Aerial Text Box Text New U/G 136 Callout Arrow ' New Aerial A New Tap Interior Path Footage Break Phase Identifier Fiber Splice Point Power Supply Ps Storage Loop CD Hard Surface Cut 0 C Riser O Abandoned Cable Provide Clear Construction Details 1. TIE POINT AT SP.WALY.0239_LY06S.3A.313.113.1A - INSTALL STRAP OUT CASE - 155' ROW AERIAL 96C FOC DELASH / RELASH - 149' ROW AERIAL 96C FOC DELASH / RELASH - 136' ROW AERIAL 96C FOC DELASH / RELASH (FLYING DUTCHMAN) - 6' ROW AERIAL 96C FOC DELASH / RELASH - 219' ROW AERIAL 96C FOC DELASH / RELASH (FLYING DUTCHMAN) - 151' ROW AERIAL 96C FOC OVERLASH - 175' ROW AERIAL 96C FOC OVERLASH - INSTALL ENCLOSURE TO TRANSITION 96C TO 12C FOC 2. 25' ROW RISER 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - 75' ROW TO PRIVATE 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - 70' ROW TO PRIVATE 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - PULL INTO EXISTING EXTERIOR LOCKBOX RECEIVED Jan 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT J 136' 219' Address: New Aerial Coax: 0 New Aerial Fiber: 991 Empty Conduit Only: 0 Are Additional Pages Needed: . YA FLYING DUTCHMAN , 219' 6' ►. FLYING DUTCHMAN -.. 15 1' LA. 21727 76TH AVE W, EDMONDS, WA 98026 Right of Way Footages: Overlash Coax: 0 New UG Fiber: Overlash Fiber: 0 Existing UG Fiber: New UG Coax: 0 Existing UG Coax: No FLYING DUTCHMAN 219' .. O n FLYING DUTCHMAN 1 N-1 Right of Way COMCAST Completed By: Completion Date: Survey Revision Date: Survey Revision Task ID: Engineered For: Project Manager: P2 ID: Legend New Ped ❑ Pole New Vault ❑V Lock Box Existing U/G Footage 150' Existing Aerial Text Box Text New U/G Callout Arrow New Aerial New Tap Interior Path Footage Break Phase Identifier ❑1 Fiber Splice Point Power Supply Ps Storage Loop CD Hard Surface Cut O Riser (D Abandoned Cable Provide Clear Construction Details 1. TIE POINT AT SP.WALY.0239_LY06S.3A.3B.1B.1A - INSTALL STRAP OUT CASE - 155' ROW AERIAL 96C FOC DELASH / RELASH - 149' ROW AERIAL 96C FOC DELASH / RELASH - 136' ROW AERIAL 96C FOC DELASH / RELASH (FLYING DUTCHMAN) - 6' ROW AERIAL 96C FOC DELASH / RELASH - 219' ROW AERIAL 96C FOC DELASH / RELASH (FLYING DUTCHMAN) - 151' ROW AERIAL 96C FOC OVERLASH - 175' ROW AERIAL 96C FOC OVERLASH - INSTALL ENCLOSURE TO TRANSITION 96C TO 12C FOC 2. 25' ROW RISER 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - 75' ROW TO PRIVATE 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - 70' ROW TO PRIVATE 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - PULL INTO EXISTING EXTERIOR LOCKBOX RECEIVED Jan 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT L,219' n 6' W. PASCHAL Address: 10/ 12/2021 New Aerial Coax: 0 New Aerial Fiber: 991 Empty Conduit Only: 0 JB0000808498 Are Additional Pages Needed: • FLYING DUTCHMAN 1k136'.. „ 151' 21727 76TH AVE W, EDMONDS, WA 98026 Right of Way Footages: Overlash Coax: 0 New UG Fiber: Overlash Fiber: 0 Existing UG Fiber: New UG Coax: 0 Existing UG Coax: No INSTALL ENCLOSURE TO TRANSITION 96C TO 12C FOC 175' 1 Y . >t INSTALL ENCLOSURE TO 1751 TRANSITION 96C TO 12C FOC 1 .0 - Right of Way COMCAST Legend New Ped ❑ Pole New Vault ❑V Lock Box Existing U/G Footage Existing Aerial Text Box New U/G Callout Arrow New Aerial New Tap Interior Path Footage Break Phase Identifier Power Su I Completed By: Completion Date: Survey Revision Date: Survey Revision Task ID: Engineered For: Project Manager: P2 ID: 150' Text ❑1 Fiber Splice Point pp y Ps Storage Loop CD Hard Surface Cut 0 Riser OAbandoned Cable Provide Clear Construction Details 1. TIE POINT AT SP.WALY.0239_LY06S.3A.3B.1 B.1A - INSTALL STRAP OUT CASE - 155' ROW AERIAL 96C FOC DELASH / RELASH - 149' ROW AERIAL 96C FOC DELASH / RELASH W.PASCHAL 10/ 12/2021 Address: New Aerial Coax: New Aerial Fiber: Empty Conduit Only 21727 76TH AVE W, EDMONDS, WA 98026 Right of Way Footages: 0 Overlash Coax: 0 New UG Fiber: 991 Overlash Fiber: 0 Existing UG Fiber: 0 New UG Coax: 0 Existing UG Coax: JB0000808498 Are Additional Pages Needed: INSTALL ENCLOSURE TO TRANSITION 96C TO 12C FOC 175' 1 --• - 136' ROW AERIAL 96C FOC DELASH / RELASH (FLYING DUTCHMAN) ", .►` - 6' ROW AERIAL 96C FOC DELASH / RELASH - 219' ROW AERIAL 96C FOC DELASH / RELASH *.,Apr a (FLYING DUTCHMAN) �.' : „ - 151' ROW AERIAL 96C FOC OVERLASH - 175' ROW AERIAL 96C FOC OVERLASH ~ ��' • -INSTALL ENCLOSURE TO TRANSITION 96C TO 12C FOC • 2. 25' ROW RISER 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - 75' ROW TO PRIVATE 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - 70' ROW TO PRIVATE 12C FOC CONDUIT PULL (EXISTING 2" CONDUIT - PROOF AND PULL) - PULL INTO EXISTING EXTERIOR LOCKBOX 3. 81' PRIVATE EXT 12C FOC THRU DROP PANEL CEILING VOID IN SUB -LEVEL PARKING GARAGE - INSTALL SPLIT DUCT RECEIVED Jan 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT y 25' R 75' 10 ' :+'+ •; No t 0 2 ry 3 A to A 00 00 ON TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP MAINTAIN TWO 11' TRAVEL LANES BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TMA ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HOST VEHICLE WEIGHT > 22,000 lbs. c 45 MPH 1 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 1 123' 172' 74' 100, 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED MINIMUM TAPER LENGTH = L (feet) Lane Width (feet) Posted Speed (mph) 25 30 35 40 45 50 55 60 65 70 10 105 150 1 205 1 270 1 450 1 500 1 550 - - - 11 115 165 225 295 495 550 605 660 - - 12 125 180 1 245 1 320 1 540 1 600 Spotter to assist pedestrians through work zone SIGN SPACING = X (FEET) ( 1 ) RURAL HIGHWAYS 60165 MPH 8001± RURAL ROADS 45/55 MPH 500'± RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350'± RURAL ROADS, URBAN ARTERIALS 25/30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200'± (2) URBAN STREETS 25 MPH OR LESS ALL SIGNS ARE 48" X 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. (1) All spacing may be adjusted to accommodate interchange ramps, at -grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. CHANNELIZING DEVICE SPACING (FEET) W1 4L R4-7B KEEP W20 1 ROAD ER TAN MPH TAPER 24" X 30" 10* WORK 50/60 40 80 B/W 00 RIGHT AHEAD 35/45 30 60 25130 20 40 30' MIN. 20' 100' MAX. R B L/2 X X FOR TMA 0 q q ° 63 WORK AREA ® ° gon 0❑ 0 Z 00 ® ° 2ft min. recommended o IT]° �_ o a❑ —°oi�00000000000000000000° — — — _ _ a a � X X L/2 L/2 DEVICE SPACING 1/2 DISTANCE SPACING 1/2 DISTANCE FOR Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or tCAHEAD occurs during the permitted project. W LEGEND IN SIGN LOCATION ® SIGN LOCATION - S MOUNTING W20-5L HEIGHT -RECOMMENDED 0 0 0 CHANNELIZING DEVICES EM PROTECTIVE VEHICLE REQUIRED OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROLAND DRAINAGE OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. OPPOSING TRAFFIC DEVICES NOTES 1. For long term projects, conflicting pavement markings no longer applicable must be removed or obliterated as soon as practicable. Temporary markings shall be used as necessary and signs shall be post mounted. 2. For speed limits of 30 mph or less, use sign W1-3 in lieu of sign W14. 3. Extend device taper across shoulder if applicable. 4. Protective vehicle with TMA required for roadways 45 mph or higher. For roads 40 mph or less - shall be a work vehicle placed strategically to shield work area. 0 0 IV TYPICAL LANE SHIFT WITH TWO WAY LEFT TURN LANE TCP 22 RECEIVED ENGINEERING DIVISION Jan 19 2023 .„)TED CITY OF EDMONDS DEVELOPMENT SERVICES Ilf'h"1� 13/06/2022 DEPARTMENT ONE LANE ROAD AHEAD WORK ZONE CONDITION (SEE CHAPTER 1.9.10) ROAD ' A - ALLOWED - CONSIDER USING A SPOTTER. N0R AXFAD B - ALLOWED - SPOTTER RECOMMENDED o_< CONSIDER ADDITIONAL WARNING SIGNS.PREPARED De os P C - NOT ALLOWED - SEE TCP 14 & 15 FOR ADDITIONAL WORK ZONE REQUIREMENTS. O Flaggers to maintain one lane of traffic at all times for overlash work crossing 218th St SW & 76th Ave W. 00 N TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP --------- ¢ WORK AREA ROAD W BE WORK PREPARED D AXEAD TO STOP L■n \/ ONE LANE ROAD AHEAD Spotter to assist pedestrians through work zone LEGEND WORK VEHICLE W/ WARNING BEACON I� (LOCATE TO SHIELD WORK VEHICL6 OS SPOTTER NE LANE ROAD AHEAD SIGHT DISTANCE DATA MINIMUM STOPPING SIGHT DISTANCE = S SPEED LIMIT 25 30 35 40 45 50 55 60 65 70 MPH DISTANCE FEET 155 200 250 305 360 425 495 570 645 730 DISTANCES SHOWN ARE MINIMUMS, USE ADDITIONAL DISTANCE WHEN POSSIBLE. n to 0 L G CD ONE LANE ROA@ GENERAL LIMITS OF AHEAD 0 CHANNELIZED INTERSECTION i o BE 5 0OM<(�>, � C ------------------------ O CD sv o' �rt CD cn CD .._ . r� NOTES: � 1. Work vehicle w/beacon located in same quadrant as -0 BED work location. PREPARED ^ D R "P 2. Repeated access to work lane not allowed. see tcp 14 & 15 for work zone requirements - condition "C1 S. 3. Restricted sight distance requires additional advance warning devices or signs, see sight distance data chart. 4. Recommend working during red phase if signalized. 5. See chapter 1.9.10 - 1.9.11 for additional direction . TYPICAL VERY SHORT DURATION WORK OPERATION "ROAD WORK AHEAD" signs to be (INTERSECTION APPLICATION) placed On all public road approaches to TCP 29 work area Or advance sign area. RECEIVED Jan 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT X C) C SIGN SPACING = X (FEET) ( 1 ) RURAL HIGHWAYS 60 / 65 MPH 8001t RURAL ROADS 45 / 55 MPH 5001t RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 3501t RURAL ROADS, URBAN ARTERIALS 25 / 30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200't (2) URBAN STREETS 25 MPH OR LESS 1001t (2) ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. (1) All spacing may be adjusted to accommodate intersections and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. A A so SO'R i OAP ®®® SOP + 2 + w20-7A BE PREPARED �� + TO STOP w20-713 (OPTIONAL IF 40 MPH OR LESS) ROAD WORK AHEAD M0-1 LEGEND FLAGGING STATION DI SIGN LOCATION ®®® CHANNELIZING DEVICES PROTECTIVE VEHICLE w W20-7A n BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 10 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TMA ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 1 123' 172' 74' 100' 150' PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50165 65 40 80 35 / 45 30 60 25/30 20 40 W20JB (OPTIONAL IF 40 MPH OR LESS) BE PREPARED ,TD STEP // \\ W20-4 ONE LANE ROAD AHEAD 5-1 ROAD WORK \'r AHEAD ONE LANE ROAD NOTES AHEAD W20-4 1. Night work requires additional roadway lighting at flagging stations. 2. Recommend extending channelizing device taper across shoulder. Channelizing devices at flagger stations recommended. 3. Protective vehicle - may be a work vehicle strategically located to shield the work area. 4. For low -volume situations with short work zones on straight roadways where the flagger is visible to road users approaching from both directions, a single flagger, positioned to be visible from both directions may a used. 5. Extend the longitudinal buffer space to locate the taper in advance of a curve, if necessary. TYPICAL ONE -LANE, TWO-WAY TRAFFIC CONTROL WITH FLAGGERS TCP 1 RECEIVED Jan 19 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT