BLD2023-0284_Site_Plan_3.6.2023_8.47.59_AM_3402799SYSTEM SUMMARY STC (12.400 kW DC / 10.819 kW STC DC: (31) 40OW = 12.400 kW STC AC: (31) 349W = 10.819 kW • (31) SOLARIA POWER X-40OR (400W) MODULES MODULES • (31) IQ8A-72-2-US MICROINVERTERS • 1x BRANCH OF 11 CONNECTED IN PARALLEL • 2x BRANCHES OF 10 CONNECTED IN PARALLEL GOVERNING CODES 2020 NATIONAL ELECTRIC CODE 2018 WASHINGTON STATE BUILDING CODE 2018 WASHINGTON STATE FIRE CODE 2018 WASHINGTON STATE RESIDENTIAL CODE 2018 WASHINGTON STATE ENERGY CODE 2018 WASHINGTON STATE EXISTING BUILDING CODE 2018 WASHINGTON STATE MECHANICAL CODE 2018 WASHINGTON STATE WILDLAND-URBAN INTERFACE CODE GENERALNOTES 1) ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS IN COMPLIANCE WITH UL REQUIREMENTS TO ACCOMMODATE CONDUCTORS SHOWN. 2) THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND UTILITY IS OBTAINED. 3) ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE ENVIRONMENT SHALL BE WEATHERPROOF AND SHALL BE LISTED BY'UL' FOR THE TYPE OF APPLICATION AND'UL' LABEL SHALL APPEAR ON ALL ELECTRICAL EQUIPMENT. 4) WIRING METHOD SHALL BE EMT ABOVE GROUND MOUhLIGGiM CONCEALED SPACES (UNI FRR nPoo D SCHEDULE-40 IIIIIIIIIIIIIIIIIIIIIIIIIIFOTHERWISE. 5) AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL PORTIONS OF THE ARRAY SHALL BE SECURED IN PRIOR TO REQUESTING INSPECTION. 6) IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE CONDUCTOR IF NECESSARY. � I 0 u PV MODULE W ■ OPTIMIZER 0 ■ MICRO -INVERTER ui _I ROOF ATTACHMENT MSP MAIN SERVICE PANEL (EXISTING, 200A) UTILITY METER UM (EXISTING) PRODUCTION METER PM (N/A) BAT BATTERY (N/A) FINV] (0) INVERTER INV (N/A) LC LOAD CENTER (COMBINER PANEL) (NEW) SOLAREDGE METER FSM s—m(N/A) BACKUP LOAD PANEL BLP (N/A) DIMENSIONS PROPERTY LINE FENCE GATE AC AC DISCONNECT UNFUSED (N/A) ACF AC DISCONNECT FUSED (NEW) FJB JUNCTION BOX (NEW) AT AUTO TRANSFORMER (N/A) SUBPANEL SUB (N/A) DC DISCONNECT DCD (N/A) DCC DC COMBINER (N/A) EE EXISTING EQUIPMENT IC ROOF MOUNT SYSTEM EM SIZE STC (12.400 KW DC / 10.819 KW AC) 199258 NDS, WA 98026, USA (47.8179748,-122.3517193) DRIVEWAY 1 SITE PLAN & SAFETY PLAN SCALE: 1/16" = 1' 125'-4" IN 125'-3" LE -0 20'-10.1 1 1 I 1 J N SHEETINDEX PV-1 COVER PAGE PV-2 ROOF PLAN WITH MODULES PV-3 ATTACHMENT DETAILS PV-4 THREE LINE DIAGRAM PV-5 WIRING CALCULATIONS PV-6 PLACARDS PV-7+ EQUIPMENT SPECIFICATION AHJ: WASHINGTON I SNOHOMISH EDMONDS UTILITY: SNOHOMISH COUNTY PUD NO 1 ARRAY LOCATION(Syl HOUSE PHOTO SCALE: NTS Ll ynnwoc Seaview Park Lynnwood THE BOWL OF EDMONDS ,farina Edmonds ach Park= WinC0 F ods Woodway Esper nce ,oa Mountlake Terrace Go,;gle— Costco Wholesale' PROJECT SITE VICINITY MAP SCALE: NTS I-N CONTRACTOR: PINNACLE ROOFING PROFESSIONALS, LLC (27530) ADDRESS: 5014 208TH ST SW LYNNWOOD WA US 98036 PHONE: (206) 919-3538 LICENSE #: PINNARP87OLP REVISIONS DESCRIPTION I DATE REV INITIAL DESIGN 103105/70231 00 SIGNATURE & SEAL HOMEOWNER INFO W 0 W 2 LU Q 1 j� wo z Q0) J < � Q 00 GD L0 N r APN: --- EMAIL: N/A PHONE: N/A SHEET NAME COVER PAGE SHEET SIZE . ANSI B 11" X 17" L EET NUMBER PV-1 (31x) SOLARIA POWER X-40OR (400W) MODULES (67.8" x 44.7" MICRO -INVERTER TYPES (COUNT, WEIGHT): • (31x) IQ8A-72-2-US (2.38 LB) ATTACHMENT COUNT: 101 MOUNTING SYSTEM WEIGHT/MODULE: 1.5 LB TOTAL ROOF AREA: 2767 SF TOTAL ARRAY AREA: (31) 67.8" x 44.7" = 652 SF TOTAL ARRAY WEIGHT: (31) 48.7 + (31) 2.4 + (31) 1.5 = 1630 LB WEIGHT AT EACH CONNECTION: 1630 LB 1101 = 16.13 LB DISTRIBUTED LOAD: 1630 LB / 652 SF = 2.50 PSF ROOF AREA COVERED BY ARRAY: 652 SF / 2767 SF = 23.6 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULES 31 SOLARIA POWER X-40OR (400W) MODULES MICRO INVERTERS 31 IQ8A-72-2-US JUNCTION BOX (AC) 1 JUNCTION BOX 600V, NEMA 3R UL LISTED LOAD CENTER (AC) 1 AC COMBINER PANEL (MIN RATING 50A) AC DISCONNECT 1 PV VISIBLE LOCKABLE LABELED DISCONNECT (60A FUSED 1 PH 240VAC) ATTACHMENTS 101 FF2 RAIL 21 XR 100 RAIL SPLICES 06 RAIL SPLICES MID CLAMPS 28 MID CLAMPS END CLAMPS 68 END CLAMPS GROUNDING LUG 17 GROUNDING LUG ROOF DESCRIPTION TABLE ROOF PLANE ROOF PITCH ROOF AZIMUTH TRUSSES SIZE TRUSSES SPACING ATTACHMENT SPACING MODULES (PITCH) #1 30° 270° 2" x 4" 24" O.C. 48" O.C. 11 (300) #2 30° 90° 2" x 4" 24" O.C. 48" O.C. 6 (30') #3 300 90° 2" x 4" 24" O.C. 48" O.C. 4 (30`) #4 30° 180° 2" x 4" 24" O.C. 48" O.C. 4 (30°) #5 300 1800 2" x 4" 24" O.C. 48" O.C. 4 (30°) #6 300 1800 2" x 4" 24" O.C. 48" O.C. 1 (30°) #7 30° 180° 2" x 4" 24" O.C. 48" O.C. 1 (30°) ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DQQB LOCATED AT STRONG POINTS OF BI ql QjUQ r tJIF'UJUKt ukk I tl7UKY = k, WIND SPEED = 110MPH SNOW LOAD = 20LBS/FT2 Q E71 PV MODULE ■ OPTIMIZER 'W V ■ MICRO -INVERTER ui J • ROOFATTACHMENT MSP MAIN SERVICE PANEL (EXISTING, 200A) UTILITY METER UM (EXISTING) PRODUCTION METER PM (N/A) BATTERY BAT (N/A) FIN (0) INVERTER V (N/A) LC LOAD CENTER (COMBINER PANEL) (NEW) SOLAREDGE METER SM (N/A) BACKUP LOAD PANEL BLP (N/A) DIMENSIONS PROPERTY LINE FENCE GATE AC AC DISCONNECT UNFUSED (N/A) AC DISCONNECT FUSED ACF (NEW) JUNCTION BOX JB (NEW) AT AUTO TRANSFORMER (N/A) SUBPANEL SUB (N/A) DC DISCONNECT DCD (N/A) DC COMBINER DCC (N/A) EE EXISTING EQUIPMENT ROOF 07 PITCH 30' AZIMUTH 180' ROOF PLAN WITH MODULES SCALE: 1 /8" = 1'-0" PITCH 30 ROOF 06 PITCH 30' AZIMUTH 180' I I i j I I •—T I I I '•• 14 6PITCH 30' if w z Q 0 C) Q W U) W N > 00 O Q O') 00 00 L0 nl ROOF PLAN WITH MODULES SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-2 GENERAL STRUCTURAL NOTES: 1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE IRONRIDGE XR100 RAIL WITH FLASH FOOT-2 ATTACHMENT. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND MUST BE STAGGERED TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5/16" LAG SCREWS WITH A MINIMUM OF 2-1/2" PENETRATION INTO ROOF FRAMING. 3. THE PROPOSED PV SYSTEM ADDS 2.6 PSF TO THE ROOF FRAMING SYSTEM. 4. ROOF LIVE LOAD = 20 PSF TYPICAL, 0 PSF UNDER NEW PV SYSTEM. 5. GROUND SNOW LOAD = 20 PSF 6. WIND SPEED = 110 MPH 7. EXPOSURE CATEGORY = C 8. MAX SPACING BETWEEN ATTACHMENTS (INCHES) = 48" ATTACHMENT DETAIL SCALE: NITS SEE ENLARGED VIE 117:` ^CPHALT SHINGLE C. P\/ AAnni II PS IRONRIDGE INTE( GROUNDING & E )NRIDGE XR10 RAIL ) ASPHALT SHINGLE FLASHING ALUMN. "L" BRACKET W/3/8" SS BOLT & NUT IRONRIDGE FLASH FOOT2 ATTACHMENTS 3.5" SS LAG BOLT MIN 212" THREAD DMENT, SEALED FRATION 2"X4" TRUSSES @24 ATTACHMENT DETAIL (ENLARGED StL I SUN VIEW) SCALE: NTS CONTRACTOR. PINNACLE ROOFING PROFESSIONALS, LLC(27530) ADDRESS: 5014 208TH ST SW LYNNWOOD WA US 98036 PHONE: (206) 919-3538 LICENSE #: PINNARP87OLP REVISIONS DESCRIPTION DATE INITIAL DESIGN 03/05/20 SIGNATURE & SEAL HOMEOWNER INFO . z O w p Q W D W o z Q 00 Q ~ Q 00 00 L0 N APN: ---- EMAIL: N/A PHONE: N/A SHEET NAME ATTACHMENT DETAIL SHEET SIZE - ANSI B 11" X 17" L EET NUMBER PV-3 SYSTEM SUMMARY STC (12.400 kW DC / 10.819 kW AC STC DC: (31) 40OW = 12.400 kW STC AC: (31) 349W = 10.819 kW • (31) SOLARIA POWER X-40OR (400W) MODULES MODULES • (31) IQ8A-72-2-US MICROINVERTERS • 1x BRANCH OF 11 CONNECTED IN PARALLEL • 2x BRANCHES OF 10 CONNECTED IN PARALLEL MOD: SOLARIA POWER X-40OR (400W) MODULES INV: IQ8A-72-2-US (240V) (1 BRANCH X 11 MICRO-INV) 11121°°111 MS-01 12 AWG Q-CABLE 06 AWG Cu BARE G (BOND RACKING) MOD: SOLARIA POWER X-40OR (400W) MODULES INV: IQ8A-72-2-US (240V) (1 BRANCH X 10 MICRO-INV) 11121--110 MS-02 , I II 12 AWG Q-CABLE 06 AWG Cu BARE G (BOND RACKING) MOD: SOLARIA POWER X-40OR (400W) MODULES INV: IQ8A-72-2-US (240V) (1 BRANCH X 10 MICRO-INV) 11121--110 MS-02 12 AWG Q-CABLE 06 AWG Cu BARE G (BOND RACKING) ELECTRICAL NOTES JUNCTION BOX 600V, NEMA 3R UL LISTED IMCB-01 TO CONSUMPTION CT IQ COMBINER 4/4C GATEWAY CT 10A/15A LC-01 20A N) 20A N) 20A N) 1) ALL GROUNDING TO COMPLY WITH NEC 690.47. 2) ROOFTOP CONDUIT SHALL BE LOCATED MIN. 7/8" ABOVE ROOF SURFACE. 3) ALL TERMINALS SHALL BE MIN. 75°C RATED. 4) IF IQ GATEWAY PRESENT, GATEWAY BREAKER DETERMINED AT FACTORY BY MANUFACTURER. 5) IF IQ GATEWAY PRESENT, FOR IQ COMBINER USE SINGLE CT ON L1. AT IQ SYSTEM CONTROLLER MAIN USE DOUBLE CT ON L1 AND L2. ELECTRICAL THREE LINE DIAGRAM SCALE: NTS PV VISIBLE LOCKABLE LABELED DISCONNECT (60A FUSED 1PH 240VAC) 60A(N) _ I LC-01 MAIN SERVICE PANEL (EXISTING, TOP -FED) BUS RATING: 200A MAIN BREAKER: 200A (E) CT 1611LLl i8ED BI-DIRECTIONAL UTILITY METER UTILITY: SNOHOMISH COUNTY PUD NO 1 SERVICE: 240V 60HZ 1 PH TO O UTILITY GRID SUPPLY SIDE TAP AC wire details Wire Min Ampacity Live Neutral Ground Min EMT Min PVC Min RMC MS-01 19.94A 12 AWG (Q-Cable) _ 06 AWG BARE (NOT IN CONDUIT) - MS-02 18.13A 12 AWG (Q-Cable) 06 AWG BARE (NOT IN CONDUIT) - MCB-01 19.94A (2) 10 AWG THWN-2 10 AWG THWN-2 08 AWG THWN-2 1/2 in 1/2 in 1/2 in MCB-02 18.13A (2) 10 AWG THWN-2 10 AWG THWN-2 08 AWG THWN-2 1/2 in 1/2 in 1/2 in LC-01 56.19A (2) 06 AWG THWN-2 06 AWG THWN-2 08 AWG THWN-2 3/4 in 3/4 in 3/4 in INTERCONNECTION 120% RULE (MAIN PANEL) INTERCONNECTION 120% RULE NOT APPLICABLE LINE -SIDE TAP DOES NOT AFFECT MAIN PANEL CONTRACTOR: PINNACLE ROOFING PROFESSIONALS, LLC(27530) ADDRESS: 5014 208TH ST SW LYNNWOOD WA US 98036 PHONE: (206) 919-3538 LICENSE #: PINNARP87OLP REVISIONS DESCRIPTION I DATE REV INITIAL DESIGN 03/05/7073 00 SIGNATURE & SEAL HOMEOWNER INFO 0 z O ~ w U) U � O LU 04 z Q00 0) J < � Q 00 00 Ln N O O) T_ APN: --- EMAIL: N/A PHONE: N/A SHEET NAME EXTREME CASE MODULE OUTPUT THREE LINE (SOLARIA POWER X-40OR (400W) MODULES) DIAGRAM Isc(25°C) = 13.68A, Tisc = 0.048A/°C sc(T) = Isc(25°C) + [Tisc x (T-25°C)](-6°C) = 12.19A, Isc(26°C) = 13.73A SHEET SIZE ANSI B c(25°C) = 37.30V, Tvoc =-0.280V/°Cc(T) L 11 X 17c(-6°C) = Voc(25°C) + [Tvoc x (T-25°C)] = 45.98V, Voc(26°C) = 37.02V SHEET NUMBER PV-4 SYSTEM SUMMARY STC (12.400 kW DC / 10.819 kW AC STC DC: (31) 40OW = 12.400 kW STC AC: (31) 349W = 10.819 kW • (31) SOLARIA POWER X-40OR (400W) MODULES MODULES • (31) IQ8A-72-2-US MICROINVERTERS • 1x BRANCH OF 11 CONNECTED IN PARALLEL • 2x BRANCHES OF 10 CONNECTED IN PARALLEL AC wire details Nominal Backfeed `1.25 Min Total Conductor ccConductors Expected Adjusted ampacity (ampacity x temp Conductor & EGC size Conductor Max V drop Min EMT Min PVC Min RMC WirelD #Modules Voltage /cond. set OCPD Power sets /conduit max temp derate x conduit fill derate) neutral size (Cu) metal length size size size 06 AWG BARE MS-01 11 240 V 19.94 A 20 A 3.8 kW 1 2 26 25 x 1.00 x - = 25.00 A 12 AWG (Q-Cable) (NOT IN CONDUIT) Cu 50 ft 1.12 % - - - 240 V 18.13 A 20 A 3.5 kW 1 2 26 25 x 1.00 x - = 25.00 A 12 AWG Q-Cable) ( 06 AWG BARE Cu 50 ft 1.02 % - - - MS-02 10 (NOT IN CONDUIT) MCB-01 11 240 V 19.94 A 20 A 3.8 kW 1 2 26 35 x 1.00 x 1.00 = 35.00 A 10 AWG THWN-2 08 AWG THWN-2 Cu 50 ft 0.67 % 1/2 in 1/2 in 1/2 in MCB-02 10 240 V 18.13 A 20 A 3.5 kW 1 2 26 35 x 1.00 x 1.00 = 35.00 A 10 AWG THWN-2 08 AWG THWN-2 Cu 50 ft 0.61 % 1/2 in 1/2 in 1/2 in LC-01 31 240 V 56.19 A 60 A 10.8 kW 1 2 26 65 x 1.00 x 1.00 = 65.00 A 06 AWG THWN-2 08 AWG THWN-2 Cu 10 ft 0.15 % 3/4 in 3/4 in 3/4 in INTERCONNECTION 120% RULE (MAIN PANEL) INTERCONNECTION 120% RULE NOT APPLICABLE LINE -SIDE TAP DOES NOT AFFECT MAIN PANEL ELECTRICAL NOTES 1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600V AND 90°C WET ENVIRONMENT. 3) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. 10) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NEC 690. 11) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. 12) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER NEC 310.15(B)(16). 13) IF IQ GATEWAY PRESENT, GATEWAY BREAKER DETERMINED AT FACTORY BY MANUFACTURER. 14) IF IQ GATEWAY PRESENT, FOR IQ COMBINER USE SINGLE CT ON L1. AT IQ SYSTEM CONTROLLER MAIN USE DOUBLE CT ON L1 AND L2. CONTRACTOR: PINNACLE ROOFING PROFESSIONALS, LLC (27530) ADDRESS: 5014 208TH ST SW LYNNWOOD WA US 98036 PHONE: (206) 919-3538 LICENSE M PINNARP87OLP REVISIONS DESCRIPTION I DATE I REV INITIAL DESIGN 103105/70731 00 SIGNATURE & SEAL HOMEOWNER INFO EXTREME CASE MODULE OUTPUT (SOLARIA POWER X-40OR (400W) MODULES) LIJ Isc(25°C) = 13.68A, Tisc = 0.048A/°C Isc(T) = Isc(25°C) + [Tisc x (T-25°C)] Isc(-6°C) = 12.19A, Isc(26°C) = 13.73A Voc(25°C) = 37.30V, Tvoc =-0.280V/°C Voc(T) = Voc(25°C) + [Tvoc x (T-25°C)] 7 Voc(-6°C) = 45.98V, Voc(26°C) = 37.02V Q J Q APN: -- EMAIL: N/A PHONE: N/A Z 0 0 LU W Q 00 00 Ln N SHEET NAME WIRING CALCULATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-5 `' WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTERS, AC DISCONNECTS, AC COMBINER BOXES CODE REF: NEC 2020 - 690.13(B) LABEL LOCATION: UTILITY SERVICE ENTRANCE (MSP OR AC DISCONNECT IF LINE SIDE TAP), AND WHEREVER REQUIRED BY AHJ (INVERTERS, DC DISCONNECTS, OTHER) CODE REF: NEC 2020 - 690.56(C)(2) LABEL LOCATION: INTERCONNECTION Placard (MSP BACKFEED BREAKER OR TAP BOX IF LINE SIDE TAP), AC DISCONNECTS CODE REF: NEC 2020 - 690.54 LABEL LOCATION: INTERCONNECTION Placard (MSP BACKFEED BREAKER OR TAP BOX IF LINE SIDE TAP), AC DISCONNECTS CODE REF: NEC 2020 - 690.13(B) LABEL LOCATION: AC DISCONNECTS FOR UTILITY ACCESS CODE REF: NEC 2020 - 690.13(B) LABEL LOCATION: N/A CODE REF: NEC 2020 - 690.56(B), NEC 2020 - 705.10 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN � TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: INTERCONNECTION POINT (MSP OR AC DISCONNECT IF LINE SIDE TAP) CODE REF: NEC 2020 - 690.56(C) LABEL LOCATION: UTILITY METER CODE REF: NEC 2020 - 690.13(B) A WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL LABEL LOCATION: MSP CODE REF: NEC 2020 - 110.27(C) CAUTION: POWER TO THIS SERVICE IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN LABEL LOCATION: MSP CODE REF: NEC 2020 - 705.10, NEC 2020 - 710.10 PRP CONTRACTOR: PINNACLE ROOFING PROFESSIONALS, LLC (27530) ADDRESS: 5014 208TH ST SW LYNNWOOD WA US 98036 PHONE: (206) 919-3538 LICENSE #: PINNARP87OLP REVISIONS DESCRIPTION I DATE I REV INITIAL DESIGN 03105/70231 00 SIGNATURE & SEAL HOMEOWNER INFO 0 0 w o j Z Q LLI Q 00 o � ao L0 N d7 APIN ---- EMAIL: N/A PHONE: N/A SHEET NAME PLACARDS SHEET SIZE - ANSI B 11" X 17" SHEET NUMBER PV-6 SOLixRIA Achieving over 20.5% efficiency, Solaria PowerX Performance solar panels feature Solaria's core cell cutting technology, offering higher -power and attractive black -on - black aesthetics compared to conventional solar panels. Solaria has been the market leader in cut -cell technologies for over a decade. With a comprehensive 25-year warranty, PowerX delivers the latest in power and reliability for homeowners. High Efficiency, High Power At 400 watts and 20.5% efficiency, Solaria PowerX solar panels are one of the highest power residential panels available. High Quality and Reliability State -of -the art cell cutting technology and advanced panel construction ensure that PowerX panels are highly reliable and designed to far exceed the industry -leading 25-year warranty. All Black Aesthetics Compared to conventional panels, Solaria PowerX panels have a more uniform all -black appearance. f � Best System Value Solaria PowerX solar panels produce more power per square It meter area. This reduces installation costs due to fewer balance of system components. Improved Shading Tolerance Sub -strings are interconnected in parallel, which dramatically lowers the shading losses and boosts energy yield. I , Low Light Performance - PowerX maintains high efficiency at low irradiance further ensuring maximum energy yield. Solaria PowerX � DC Panel SOLARIA Solaria PowerX- 390R 395R 40OR Max Power (Pmax) [W] 390 395 400 Efficiency [ni] 20.0 20.2 20.5 Open Circuit Voltage (Voc) IV] 36.9 37.1 37.3 Short Circuit Current (Ise) [A] 13.52 13.60 13.68 Max Power Voltage (Vmp) IV] 30.6 30.8 31.0 Max Power Current (Imp) [A] 12.73 12.82 12.9 Power Tolerance 1%] -0/+3 -0/+3 -0/+3 Performance at O :rr r' Max Power (Pmax) [W] 290 293 297 Open Circuit Voltage (Voc) IV] 34.3 34.5 34.7 Short Circuit Current (Ise) [A] 11.01 11.10 11.13 Max Power Voltage (Vmp) IV] 28.50 28.60 28.76 Max Power Current (Imp) [A] 10.20 10.26 10.32 Temperature Characteristics NOCT [°C] 45 +/-2 Temp. Coeff. of Pmax [%/ oc] -0.36 Temp. Coeff. of Voc [%/ aC] -0.28 Temp. Coeff. of Isc I% / ocl 0.048 Design Operating temperature loci -40 to +85 Max System Voltage IV] 1000 Max Fuse Rating [A] 25 Bypass Diodes [#] 3 16 14 _ 12 a 10 z 6 - 4 2 0 0 5 10 15 20 25 30 35 40 VOLTAGE M -1000 W/m^2 -800 W/m^2 -600 W/W2 -400 W/m-2 -200 W/m"2 100% 25-year Power, Parts and Labor from Solaria 98% Typical Tier 1 industry warranty 90% - 86% 80% - 81 % 5 10 15 20 25 Years Solaria PowerX-400R Cell Type Monocrystalline Silicon Dimensions (L x W x H) 67.8" x 44.7" x 1.4" 1723mm x 1134mm x 35mm Weight 22.1 kg / 48.71bs Glass Type / Thickness AR Coated, Tempered / 3.2mm Frame Type Black Anodized Aluminum Cable Type / Length 12 AWG PV Wire (UL) /1100mm Connector Type MC4 Junction Box IP68 / 3 diodes Front Load 5400 Pa / 113 psf* Rear Load 2400 Pa / 50 psf* *Refer to Solaria Installation Manual for details Certifications UL 61730 / IEC 61215 / IEC 61730 Fire Type (UL 1703) 2 Power, Parts & Labor 25 years* Warranty *Warranty details at www.solaria.com Stacking Method Vertical / Palletized Panels/ Pallet 31 Pallet Dims (L x W x H) 69.3" x 44.3" x 49.3" 1760mm x 1125mm x 1253mm Pallet Weight 745 kg / 1642 Ibs Pallets / 40-ft Container 26 Panels / 40-ft Container 806 [0.3ftl I 35.0m35.Om Mom m The Solaria Corporation 45700 Northport Loop East, Fremont, CA 94538 P: (510) 270-2507 www.solaria.com Copyright © 2022 The Solaria Corporation The Solaria Corporation 45700 Northport Loop East, Fremont, CA 94538 P: (510) 270-2507 www.solaria.com Copyright © 2022 The Solaria Corporation Product specifications are subject to change without notice. SOL-DAT-0010 Rev 02 5-2022 Product specifications are subject to change without notice. SOL-DAT-0010 Rev 02 5-2022 Lt4 CONTRACTOR: PINNACLE ROOFING PROFESSIONALS, LLC (27530) ADDRESS: 5014 208TH ST SW LYNNWOOD WA US 98036 PHONE: (206) 919-3538 LICENSE #: PINNARP87OLP REVISIONS DESCRIPTION I DATE I REV INITIAL DESIGN 103105/70231 00 SIGNATURE & SEAL HOMEOWNER INFO W 0 Z 0 W o Q W D w o Z Q o 00 00 L0 N T_ APN: -- EMAIL: N/A PHONE: N/A SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11rr X 17" SHEET NUMBER PV-7 n ENPHASE IQ8M and IQ8A Microinverters Our newest I08 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC) which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super -fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, I08 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. Connect PV modules quickly and easily to I08 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. I08 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer's instructions. © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8MA-DS-0003-01-E N-US-2021-10-19 Easy to install Lightweight and compact with plug-n-play connectors Power Line Communication (PLC) between components Faster installation with simple two -wire cabling High productivity and reliability Produce power even when the grid is down More than one million cumulative hours of testing Class 11 double -insulated enclosure Optimized for the latest high- powered PV modules Microgrid-forming Complies with the latest advanced grid support Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 21(UL 1741-SA) requirements LZ4 IQ8M and IQ8A Microinverters Commonly used module pairings' w 260 - 460 295 - 500 CONTRACTOR: PINNACLE ROOFING PROFESSIONALS, LLC (27530) Module compatibility 60-cell/120 half -Cell and 72-Cell/144 half -cell ADDRESS: 5014 208TH ST SW LYNNWOOD MPPT voltage range v 33 - 45 36 - 45 WA US 98036 PHONE: (206) 919-3538 Operating range v 25 - 58 LICENSE #: PINNARP87OLP Min/max start voltage v 30/58 REVISIONS Max input DC voltage v 60 DESCRIPTION I DATE REV Max DC current2[module lsc] A 15 INITIAL DESIGN 103105/20231 00 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit Peak output power VA 330 366 SIGNATURE &SEAL Max continuous output power VA 325 349 Nominal (L-L) voltage/range3 v 240 / 211- 264 Max continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 50 - 68 Max units per 20 A (L-L) branch circuit' 11 Total harmonic distortion <5 % Overvoltage class AC port III HOMEOWNER INFO AC port backfeed current mA 30 co Power factor setting 1.0 Grid -tied power factor (adjustable) 0.85leading - 0.85lagging Z Peak efficiency % 97.6 97.6 0C CEC weighted efficiency % 97 97.5 w G Night-time power consumption mw 60 p < W MECHANICAL DATA Ambient temperature range -400Cto+600C(-40°Fto+1400F) D i Relative humidity range 4%to 100%(condensing) --) w N DC Connector type MC4 Z > C) 00 Dimensions (HxWxD) 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") Q M Weight 1.08 kg (2.38lbs) = Q Cooling Natural convection - no fans 00 Approved for wet locations Yes 00 Acoustic noise at 1 m <60 dBA LI'� Pollution degree PD3 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor APN: -- r EMAIL: N/A CA Rule 21(UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class 6, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 PHONE: N/A Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section SHEET NAME 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer's instructions. EQUIPMENT SPECIFICATION (1) No enforced DC/AC ratio. See the compatibility calculator at https://Iink.enphase.com/ module -compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8MA-DS-0003-01-EN-US-2021-10-19 SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-8 Data Sheet Enphase Networking IQ Combiner 4/4C X2-IQ-AM1-240-4 (IEEE 1547:2018) U� LISTED To learn more about Enphase offerings, visit enohase.com I Q-C-4-4C-DS-0103-EN-U S-12-29-2022 The IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart Includes IQ Gateway for communication and control Includes Mobile Connect cellular modem (CELLMODEM-M7-06-SP-05), included only with IQ Combiner 4C Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat Supports Wi-Fi, Ethernet, or cellular connectivity Optional AC receptacle available for PLC bridge Provides production metering and consumption monitoring Simple Mounts on single stud with centered brackets Supports bottom, back and side conduit entry Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included) 80A total PV or storage branch circuits Reliable Durable NRTL-certified NEMA type 3R enclosure Five-year limited warranty Two years labor reimbursement program coverage included for both the IQ Combiner SKU's UL listed X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with IEEE 1547:2018 (UL 1741-SB, 3r' Ed.) n ENPHASE IQ Combiner 4/4C MODEL NUMBER IQ Combiner 4 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20±0.5%) and consumption monitoring (±2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat. IQ Combiner 4C IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20±0.5%) X-IQ-AM1-240-4C and consumption monitoring (±2.5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug -and -play X2-IQ-AM1-240-4C (IEEE 1547:2018) industrial -grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IQ8) Communications Kit COMMS-CELLMODEM-M1-06 - Includes COMMS-KIT-01 and CELLMODEM-MI-06-SP-05 with 5-year Sprint data plan CELLMODEM-M1-06-SP-05 -4G based LTE-M1 cellular modem with 5-year Sprint data plan CELLMODEM-M1-06-AT-05 -4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2-240V Circuit breaker, 2 pole, 10A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2 pole, 15A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2 pole, 20A, Eaton BR220 BRK-15A-2P-240V-B Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support BRK-20A-2P-24OV-B Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner4/4C (required for EPLC-01) X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breakerwith screws Consumption monitoring CT A pair of 200A split core current transformers (CT-200-SPLIT/CT-200-CLAM P) ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240VAC, 60 Hz Eaton BR series busbar rating 125A Max. continuous current rating 65A Max. continuous current rating (inputfrom PV/storage) 64A Max. fuse/circuit rating (output) 90A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input) 80A of distributed generation/95A with IQ Gateway breaker included IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre -installed and wired to IQ Gateway MECHANICAL DATA Dimensions (WxHxD) 37.5 cm x 49.5 cm x 16.8 cm (14.75 in x 19.5 in x 6.63 in). Height is 53.5 cm (21.06 in) with mounting brackets. Weight 7.5 kg (16.51bs) Ambient temperature range -40°C to +46°C (-401F to 115°F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMAtype 3R, polycarbonate construction Wire sizes 20A to 50A breaker inputs: 14 to 4 AWG copper conductors • 60A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output:10 to 2/0 AWG copper conductors • Neutral and ground: 14to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude Up to 3,000 meters (9,842 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi IEEE 802.11b/g/n Cellular CELLMODEM-MI-06-SP-05, CELLMODEM-MI-06-AT-05 (413 based LTE-M1 cellular modem). Notethatan Mobile Connect cellular modem is required forall Enphase Energy System installations. Ethernet Optional, IEEE 802.3, Cat5E (or Cat6) UTP Ethernet cable (not included) COMPLIANCE Compliance, IQ Combiner CA Rule 21 (UL 1741-SA) IEEE 1547:2018 - UL 1741-SB, 3ftl Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) ' Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ-C-4-4C-DS-0103-EN-US-12-29-2022 CONTRACTOR: PINNACLE ROOFING PROFESSIONALS, LLC (27530) ADDRESS: 5014 208TH ST SW LYNNWOOD WA US 98036 PHONE: (206) 919-3538 LICENSE #: PINNARP87OLP REVISIONS DESCRIPTION I DATE I REV INITIAL DESIGN 03/05/7073 00 SIGNATURE & SEAL HOMEOWNER INFO W 0 Z O Wo ��'Q///) 11J D LLI Z Q O o I- 00 00 L0 N r APN: -- EMAIL: N/A PHONE: N/A SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-9 .. 1* PRP /lr IRON RIDGE XR Rail Famil Y XR Rails XR10 Rail XR100 Rail XR1000 Rail Internal Splices -D Solar Is Not Always Sunny \\ Over their lifetime, solar panels experience countless CONTRACTOR PINNACLE ROOFING PROFESSIONALS, LLC (27530) ADDRESS: 5014 208TH ST SW LYNNWOOD WA US extreme weather events. Not just the worst storms in years, - — (6 PHONE:NE:20 PH #: PINNARP8 LICENSE #: PINNARP870LP but the worst storms in 40 years. High winds capable of ripping panels from a roof, and Snowfalls weighing S Alow-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices REVISIONS DESCRIPTION DATE REV enough to buckle a frame. for regions with light snow. solar mounting rail. rail for commercial for seamless connections. panel � XR Rails are the structural backbone preventing �. these results. They resist uplift, protect against buckling and safely and efficiently 4 6' spanning capability Moderate load capability •Clear &black anod. finish 8' spanning capability Heavy load capability •Clear &black anod. finish projects. 12' spanning capability Extreme load capability •Clear anodized finish • Self -tapping screws •Varying versions for rails Grounding Straps offered INITIAL DESIGN 03/05/2023 00 transfer loads into the building structure. ®®` -� Attachments Their superior spanning capability requires fewer roof attachments, ® reducing the number of roof FlashFoot Slotted L-Feet Standoffs Tilt Legs SIGNATURE &SEAL penetrations and the amount of installation time. ' i 11 "Fir IAnchor, flash, and mount with all -in -one attachments. Drop -in design for rapid rail attachment. Raise flush or tilted systems to various heights. Tilt assembly to desired angle, up to 45 degrees. HOMEOWNER INFO / Ships with all hardware High -friction serrated face Works with vent flashing Attaches directly to rail (n • IBC & IRC compliant Heavy-duty profile shape Ships pre -assembled Ships with all hardware 0 • Certified with XR Rails Clear & black anod. finish 4" and 7" Lengths Fixed and adjustable O \ Clamps & Grounding — LJJ 2 Q Force -Stabilizing Curve End Clamps Grounding Mid Clamps T Bolt Grounding Lugs Accessories W U) Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both LLI N � i directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. 7 00 L Q 0) Q � �- � = Q � J �: Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and Q 00 00 \1 modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. 00 Mill finish & black anod. Parallel bonding T-bolt Easy top -slot mounting Snap -in Wire Clips 00 • Sizes from 1.22" to 2.3" Reusable up to 10 times Eliminates pre -drilling Perfected End Caps • Optional Under Clamps Mill & black stainless Swivels in any direction UV -protected polymer APN: --- Free Resources EMAIL: NIA PHONE: NIA Compatible with Flat & Pitched Roofs Corrosion -Resistant Materials XR Rails are Iron Ridge offers All XR Rails are made of marine -grade compatible with � � a range of tilt leg aluminum alloy, then protected with an AFlashFoot and options for flat anodized finish. Anodizing prevents surface Design _ _ = GO from Assistant rough layout t0 fully ♦ NABCEP Certified 1 Earn free continuing Training education credits, SHEET NAME EQUIPMENT other pitched roof roof mounting and structural corrosion, while also providing engineered system. For free. A•♦ while learning more about our systems. SPECIFICATION attachments. applications. a more attractive appearance. �® - _ _ - Go to IronRidge.com/rm ♦ Go to IronRidge.corn/iraining SHEET SIZE . ANSI B 11" X 17" o , :., SHEET NUMBER PV-10 RIP /lr IRON RIDGE FlashFoot2 Installation Features CONTRACTOR PINNACLE ROOFING The Strongest Attachment in Solar ; B A Alignment Markers PROFESSIONALS, LLC(27530) IronRidge FlashFoot2 raises the bar in solar roof ADDRESS: 5014 208TH ST SW LYNNWOOD WA US98036 protection. The unique water seal design is both Quickly align the flashing with chalk lines to find pilot holes. PHONE: (206) 919-3538 elevated and encapsulated, delivering redundant layers �i' LICENSE #: PINNARP87OLP of protection against water intrusion. In addition, the REVISIONS DESCRIPTION DATE REV twist -on Cap perfectly aligns the rail attachment with the Li C INITIAL DESIGN 03/05/2023 00 lag bolt to maximize mechanical strength. i T L B Rounded Corners Makes it easier to handle and insert under the roof shingles. Ow C Reinforcement Ribs SIGNATURE & SEAL A � Twist -On Cap I Help to stiffen the flashing and prevent any bending or FlashFoot2's unique Cap design encapsulates crinkling during installation. the lag bolt and locks into place with a simple Three -Tier Water Seat twist. The Cap helps FlashFoot2 deliver FlashFoot2's seal architecture utilizes three superior structural strength, by aligning layers of protection. An elevated platform the rail and lag bolt in a concentric diverts water away, while a stack of rugged load path. components raises the seal an entire inch. The seal is then fully-encapuslated by the HOMEOWNER INFO Cap. FlashFoot2 is the first solar attachment — to pass the TAS-100 Wind -Driven Rain Test. Benefits of Concentric Loading ,Zoo Q a:_FlashFoot2 1000 � � _ z Traditional solar attachments have a _ , O horizontal offset between the rail and lag y soo — • FlashFoot =Leading Competitor G LIJ C bolt, which introduces leverage on the lag Q 600 Q bolt and decreases uplift capacity. u LU U) w aoo '0 Low -Cost Competitor FlashFoot2 is the only product to align the zoo rail and lag bolt. This concentric loading N design results in a stronger attachment for 0 1 2 3 ; C:)the Z 00 �. system. Rail -to -Lag Offset (in) Q 05 J = Q ~ ao Q 00 Testing & Certification u7 N Structural Certification 00 O� Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. Size Single Socket Size A custom -design lag bolt allows Water Seal Ratings --- EMAIL: NIA PHONE: N/A SHEET NAME you to install FlashFoot2 with Water Sealing Tested to 1441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. the same 7/16" socket size used on other Flush Mount Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. EQUIPMENT System components. Water -Shedding Design UL 2703 SPECIFICATION a An elevated platform diverts water away from the water seal. Conforms to 12703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. SHEET SIZE . ANSI B 11" X 17" SHEET NUMBER PV-11