ENG2022-0435 ROW PERMIToff' EIDM
�~ o�RIGHT OF WAY EUC PERMIT
o
,
EdmondsCity of Edmonds PERMIT NU
98020 1 1
www.edmondswa.gov i AM&- -
Description: COMCAST-OVERLASH FIBER PULL THROUGH EX CONDUIT TO PROPERTY
ISSUED: 03/06/2023
Address: 8130 240TH ST SW EDMONDS WA 98026-9119
EXPIRES: 09/06/2023
Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 00491100000301
CONTACTS
NAME TYPE NAME ADDRESS PHONE
APPLICANT JESSAMIN SANTOS
410 VALLEY AVE NW, PUYALLUP WA 98371 (206)401-2188
CONTACT CCI SYSTEMS
105 KENTST, IRON MOUNTAIN MI49801 (615)962-4402
CONTRACTOR CABLECOM LLC
19910 NORTHCREEK PARKWAY NORTH, SUITE 100, BOTHELL (360)863-2628
WA 98011
OWNER DELTA TWO LLC
5606 105TH AVE NE, KIRKLAND WA 98033
FEE INFORMATION
DESCRIPTION
AMOUNT PAID
CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $40.00
ENGINEERING INSPECTION FEE $110.00 $110.00
RIGHT OF WAY MINOR - EUC PERMIT FEE $110.00 $110.00
REQUIREMENTS
REQUIREMENT TYPE NOTES
TRAFFIC CONTROL
Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification
verifying completion of the required training in their posession.
RESTORATION
Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with
asphalt or City approved material prior to the end of the workday - No Exceptions
WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final
inspection and acceptance of the work.
INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM
24 HR NOTICE REQUIRED
INDEMNITY
The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of
any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its
departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney
fees by reason of granting this permit.
RELEASED BY: MAJ DATE: 03/06/2023
Printed: Monday, March 06, 2023 3:13:11 PM 1 of 2
RIGHT PERMIT
PERMIT NUM
City of Edmonds
Edmonds WA 98020
www.edmondswa.gov / 425.1 1
CONDITIONS
CONDITION TYPE
NOTES
ALERT RESIDENTS
ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START.
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD
ESC REQUIREMENTS
REQUIREMENTS.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to
indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and
agents from any and all claims for damages of whatever nature, arising directly or indirectly from the
HOLD HARMLESS
issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any
requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT.
INSPECTIONS
www.mybuildingpermit.com
POTHOLING
VERIFY CLEAR BORE CROSSINGS.
RESTORE LANDSCAPE
Restore landscape to like or better conditions
Sound or noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on
SOUND AND NOISE
weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites and activities must comply with the noise
limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
INSPECTIONS
INSPECTION TYPE
DATE
RESULT
NOTES
COMPLETE
A-1 JOB START
E-7 TRAFFIC CTRL
X-2 ENGINEERING FINAL"
Printed: Monday, March 06, 2023 3:13:11 PM 2 of 2
RECEIVED
of EpM04O�
/'Vc. i Ba 3
SECTION A
RIGHT OF WAY CONSTRUCTION
PERMIT APPLICATION
Complete and submit this Application in accordance with the Submittal
Requirements outlined in Right-of-Wgy permit Handout E6�.
SEP 12 2022
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
If any field is not applicable to your project, write "N/A' instead of leaving blank.
All fields required. Incomplete Applications will be denied.
General •
Project Name JB-1o6o696
Site Address or if no site address use Property Address at NW corner of project area: $130 24oTH ST SW, APT B2, EDMONDS, WA 98026
Associated Permits: BLD PLN ENG
Owner and Entity Holding
Name of Company Comcast Cable Communications Management, LLC. Franchise Ordinance No:
Point of Contact Jessamin Santos
Title Permit Coordinator
Address 410 Valley Ave NW
City Puyallup
State WA
Zip 98371
Phone (2o6) 401-2188
Email jessamin_santos@cable.comcast.com
Contractor and Authorized Agent of Owner
Name of Company Cablecomm, LLC
(see note below)
Contractor Contacts During Construction
Primary Name CHRIS ATKINSON
Agent Name Leah Ihlenfeldt
Title Construction Supervior
Title Permit Coordinator
Mobile 36o-926-3437
Address 1316 BONNEVILLE AVE ,BLDG A,
Email CHRIS.ATKINSON@CABLECOMLLC.NET
City Snohomish
State wA
Zip 98290
Secondary Name
Phone (36o) 668-1300
Title
Email leah.ihlenfeldt@cablecomllc.net
Mobile
City of Edmonds Business License No: NR-o21818
Email
State License No: CABLE-971DP
® Contractor verifies it is currently bonded
® Contractor verifies it currently has general liability insurance
NOTE: ECDC 18.6o. o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city
engineer.
❑ Multifamily residential ❑ Commercial ❑ City project
❑ Single family residential subdivision ❑ Single family -other ❑ Industrial
❑ Demo and rebuild or from vacant land?
❑ Other, please specify:
❑ Utility Franchise Work associated with development (check one of the above boxes as welt
❑ Traffic Control Only (no associated development)
X Utility Franchise Work (no associated development)
City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021
Include an overall narrative description of the proposed work. Be specific and detailed:
Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc.
Include whether this is construction, maintenance, or repair.
Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for
underground utilities, etc.)
Comcast JB io6o696: The proposed in the ROW is to overlash up to 3,SSo' of 96ct fiber to existing Comcast
strand; along the 76th Ave W / 238th PI SW / 78th Ave W / 24oth St SW to riser pole; proof existing riser /
buried conduit and pull new 12ct fiber 62' from ROW to private to address 8130 24oTH ST SW, APT B2,
EDMONDS, WA 98026. * No disturbance of surface.
RIGHT-OF-WAY
CLOSURE
AREA
TOTAL
DURATION
(Number of Months)
Sidewalk 72 hours +
LF
x
LF
SF
NA
Alley 72 hours +
LF
x
LF
SF
NA
Parking 72 hours +
LF
x
LF
SF
NA
SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C.
1. The work in the right of way is on or for the following type of facilities:
❑ telecommunications X cable (fiber) ❑ power ❑ gas
❑ water ❑ sewer ❑ storm
Details of Work to be Completed
1. Does the utility owner have existing overhead infrastructure in the area of work?
Yes
X
No
2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)?
X
If yes, describe:
3.
Does the proposed work connect a lot or commercial development with utilities that serve more
than one lot or commercial development?
X
4.
Does the work involve rebuilding or relocating an existing aboveground utility system which
connects a lot or commercial development to an existing underground common utility stem?
X
5.
Does the work involve proposed additions to an aboveground utility stem? If es:
X
Are the additions for the purpose of serving new commercial development?
X
Are the additions for the purpose of serving a single-family residential subdivision?
X
Details
of Work to be Completed
Yes
No
6.
Does your project involve rebuilding or replacing utility equipment which currently serves more
than one lot or commercial development?
If yes, answer the following questions related to project area, i.e. the actual area in which the
X
project is proposed:
6a.
Does your project involve wires/cables/lines? If yes:
X
How many are existing? 1 1-2 1How many are to be added? 1
City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021
6b.
Does your project involve poles? If yes:
X
How many poles are existing in the project area?
21
What is the height of the existing poles? 45' to 55
How many poles are to be removed?
o
Are additional poles to be laced?
X
How many? I I What is the height of the additionalpoles?
6c.
Are any poles to be modified/rebuilt/replaced? If yes:
X
How many? I I What is the height of the poles after?
Describe the modification rebuild:
SECTION C
Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as
required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have
certification verifying completion of the required training in their possession.
Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS.
Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to
any permit approval.
Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials,
officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever,
foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or
omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose
acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and
specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any
respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the
expiration, revocation, or termination of any resulting permit approval.
Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and
requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to
the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal
Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable
requirements of state and federal law.
Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a
licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by
owner to act on its behalf and have authority to bind the owner to this application.
Fees. The Applicant is responsibleforall permit fees.
APPLICANT SIGNATURE: Je SaW(n , Saht0S
APPLICANT PRINTED NAME: Jessamin Santos
APPLICANT TITLE: Permit Coordinator
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
8/26/2022
City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021
Applicant shall repair/replace all
damage to utilities or frontage OWNER/CONTRACTOR IS RESPONSIBLE FOR OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
mprovements in City right-of-way ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
per city standards that is caused or EROSION CONTROL AND DRAINAGE UTILITIES MAY REQUIRE A SEPERATE PERMIT.
occurs during the permitted project.
ENGINEERING DIVISION
,.,..,�. •'7TED
t(I6
-}2V 13/06/2023
Right of Way
Completed By:
Nathan Lindae-Fregoso
Address: 8130240TH ST SW APT B2 EDMONDS WA 98026
Completion Date:
8/2/2022
Right of Way Footages:
C O M C A S T
Job Type:
Metro F Retail
New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 62
New Aerial Fiber: 0 Overlash Fiber: 3550 Existing UG Fiber: 0
Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0
Are Additional Pages Needed: No
Job Subtype:
Fiber
Survey Scope:
Post -Sale
Project Manager:
P21D:
JB0001060696
*IMPORTANT CONSIDERATIONS FOR RIGHT OF WAY COMPLETION*
NOTE ALL FUTURE PEDESTAL / VAULT LOCATIONS
ENSURE YOU HAVE VERIFIED THE EXISTING COMCAST FACILITIES (FIBER / CASE LOCATIONS / SHEATHS PER CASE / SLACK LOCATIONS / FOOTAGE / STRUCTURE) SHOWN ON THE FACILITY SEARCH MAP WITHIN THE
CONSTRUCTION AREA.
SHOW ENTIRE ROUTE FROM TIE IN TO CUSTOMER LOCATION
Legend - _ -A
New Ped Pole ® (' _ WVV
— ,
New Vault V Lock Box
Existing U/G —~ TIE-IN I wpm%�
FootageSP.
Existing Aerial I� PLACE NEW STRAP Text Box Text RAP OUT C SE ,
New U/G 191, — .,,i
Callout Arrow
New Aerial Q '� ] t; r- [ r 11 rim 1!
New Tap ri
Interior Path 262,E f.
Footage Break Phase Identifier ❑1
Fiber Splice Point u Power Supply '
Storage Loop M Hard Surface Cut • ��� 215'
Riser w dd Cabl
e ® 10 ,� OVERLASH NEW FIBER DOWN 21 �, '' 40
POLES 20 SPANS 3,550'. _
Provide Clear Construction Details —� �� >ni Y^� zoo'
1. TIE-IN SP.WALY.0199_LY06S.3A.6A. 2. PLACE NEW STRAP
OUT CASE. 3. BEGIN FIBER OVERLASH 3 550 DOWN 21 �—
POLES, 20 SPANS. 4. BEGIN PROOF AND PULL THROUGH '
EXISTING 2" CONDUIT 62' TO BUILDING. 5. BEGIN NEW L _ 199
BUILDING EXTERIOR PATH 15' FOLLOWING EXISTING COAX r r
LINE. 6. BEGIN NEW BUILDING INTERIOR PATH 30' TO
SERVER ROOM FOLLOWING EXISTING COAX LINE. 7. PLAC
PROPER FIBER EQUIPMENT.
RECEIVED
SEP 12 2022 47'
r
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
Right of Way
Completed By:
Nathan Lindae-Fregoso
Address: 8130240TH ST SW APT B2 EDMONDS WA 98026
Completion Date:
8/2/2022
Right of Way Footages:
C O M C A S T
Job Type:
Metro F Retail
New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 62
New Aerial Fiber: 0 Overlash Fiber: 3550 Existing UG Fiber: 0
Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0
Are Additional Pages Needed: No
Job Subtype:
Fiber
Survey Scope:
Post -Sale
Project Manager:
P2 ID:
JB0001060696
*IMPORTANT CONSIDERATIONS FOR RIGHT OF WAY COMPLETION*
NOTE ALL FUTURE PEDESTAL / VAULT LOCATIONS
ENSURE YOU HAVE VERIFIED THE EXISTING COMCAST FACILITIES (FIBER / CASE LOCATIONS / SHEATHS PER CASE / SLACK LOCATIONS / FOOTAGE / STRUCTURE) SHOWN ON THE FACILITY SEARCH MAP WITHIN THE
CONSTRUCTION AREA.
SHOW ENTIRE ROUTE FROM TIE IN TO CUSTOMER LOCATION
Legend � I ; _ s; I'— . 11 .
New Ped ❑ Pole ky
New Vault
v Lock Box 1 ✓ f
Existing U/G Footage 150'
Existing Aerial
Text Box Text
New U/G
Callout Arrow P
New Aerial
Q b
Interior Path New Tap
Footage Break Phase Identifier
Fiber Splice Point u Power Supply y�
Storage Loop IF Hard Surface Cut O EXISTING 2" RISER ON
MPOLE.
Riser n Abandoned Cable
Provide Clear Construction Details
1. TIE-IN SP.WALY.0199_LY06S.3A.6A. 2. PLACE NEW STRAP
OUT CASE. 3. BEGIN FIBER OVERLASH 3,550' DOWN 21 W--
POLES, 20 SPANS. 4. BEGIN PROOF AND PULL THROUGH
EXISTING 2" CONDUIT 62' TO BUILDING. 5. BEGIN NEW
BUILDING EXTERIOR PATH 15' FOLLOWING EXISTING COAX
LINE. 6. BEGIN NEW BUILDING INTERIOR PATH 30' TO
SERVER ROOM FOLLOWING EXISTING COAX LINE. 7. PLACE
PROPER FIBER EQUIPMENT. 4
RECEIVED �■
EXISTING COAX LINE RAN
S E P 12 2022 BARE WIRE THROUGH
BUILDING TO LOCKBOX.
FOLLOW EXISTING LINE
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
lir I'', • &S, 11
EXISTING 2" CONDUIT 11
FROM POLE TO SIDE OF r a
BUILDING. PROOF AND
PULL 62'�
OVERLASH NEW FIBER DOWN 21 47
POLES 20 SPANS 3,550'.
L-s
k
169'
1'10I thPI SW
, U W �I
Private Exterior
Completed By:
Nathan Lindae-Fregoso
Address: 8130 240TH ST SW APT B2 EDMONDS WA 98026
Completion Date:
8/2/2022
Private Exterior Footages:
, • T
jJ�V/�, A I
CO
Job Type:
Metro E Retail
New Aerial Coax: Overlash Coax: New UG Fiber:
New Aerial Fiber: Overlash Fiber: Existing UG Fiber:
Empty Conduit Only: New UG Coax: Existing UG Coax:
Are Additional Pages Needed: No
Job Subtype:
Fiber
Survey Scope:
Post -Sale
Project Manager:
P2ID:
JB0001060696
*IMPORTANT CONSIDERATIONS FOR PRIVATE EXTERIOR COMPLETION*
NOTE ALL FUTURE PEDESTAL / VAULT LOCATIONS.
ENSURE YOU HAVE VERIFIED THE EXISTING COMCAST FACILITIES (FIBER / CASE LOCATIONS / SHEATHS PER CASE / SLACK LOCATIONS / FOOTAGE / STRUCTURE) SHOWN ON THE FACILITY SEARCH MAP WITHIN THE
CONSTRUCTION AREA.
Legend
New Ped
Pole
New Vault
v
Lock Box
Existing U/G
Footage
150'
Existing Aerial
Text Box
Text
New U/G
Callout Arrow
New Aerial
New Tap
0
Interior Path
Footage Break
Phase Identifier
0
Fiber Splice Point
Power Supply
■
Storage Loop
(�`(�
�®
Hard Surface Cut
•
Riser
Abandoned Cable
Provide Clear Construction Details
1. TIE-IN SP.WALY.0199_LY06S.3A.6A. 2. PLACE NEW STRAP
OUT CASE. 3. BEGIN FIBER OVERLASH 3,550' DOWN 21
POLES, 20 SPANS. 4. BEGIN PROOF AND PULL THROUGH
EXISTING 2" CONDUIT 62' TO BUILDING. 5. BEGIN NEW
BUILDING EXTERIOR PATH 15FOLLOWING EXISTING COAX
LINE. 6. BEGIN NEW BUILDING INTERIOR PATH 30' TO
SERVER ROOM FOLLOWING EXISTING COAX LINE. 7. PLACE
PROPER FIBER EQUIPMENT.
RECEIVED
SEP 12 2022
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
TIE-IN SP.WALY.0199_LY06S.3A.6A
PLACE NEW STRAP OUT CASE
3550'
3550'
� i Y
Private Exterior
Completed By:
Nathan Lindae-Fregoso
Address: 8130 240TH ST SW APT B2 EDMONDS WA 98026
Completion Date:
8/2/2022
Private Exterior Footages:
' `
'\V/�f ICAST
CO
Job Type:
Metro E Retail
New Aerial Coax: Overlash Coax: New UG Fiber:
New Aerial Fiber: Overlash Fiber: Existing UG Fiber:
Empty Conduit Only: New UG Coax: Existing UG Coax:
Are Additional Pages Needed: No
Job Subtype:
Fiber
Survey Scope:
Post -Sale
Project Manager:
P2ID:
JB0001060696
*IMPORTANT CONSIDERATIONS FOR PRIVATE EXTERIOR COMPLETION*
NOTE ALL FUTURE PEDESTAL / VAULT LOCATIONS.
ENSURE YOU HAVE VERIFIED THE EXISTING COMCAST FACILITIES (FIBER / CASE LOCATIONS / SHEATHS PER CASE / SLACK LOCATIONS / FOOTAGE / STRUCTURE) SHOWN ON THE FACILITY SEARCH MAP WITHIN THE
CONSTRUCTION AREA.
Legend
New Ped
Pole
New Vault
v
Lock Box
Existing U/G
Footage
I50'
Existing Aerial
Text Box
Text
New U/G
Callout Arrow
New Aerial
New Tap
0
Interior Path
Footage Break
Phase Identifier
�1
Fiber Splice Point
Power Supply
■
Storage Loop
co
Hard Surface Cut
•
Riser
®
Abandoned Cable
Provide Clear Construction Details
1. TIE-IN SP.WALY.0199_LY06S.3A.6A. 2. PLACE NEW STRAP
OUT CASE. 3. BEGIN FIBER OVERLASH 3,550' DOWN 21
POLES, 20 SPANS. 4. BEGIN PROOF AND PULL THROUGH
EXISTING 2" CONDUIT 62' TO BUILDING. 5. BEGIN NEW
BUILDING EXTERIOR PATH 15FOLLOWING EXISTING COAX
LINE. 6. BEGIN NEW BUILDING INTERIOR PATH 30' TO
SERVER ROOM FOLLOWING EXISTING COAX LINE. 7. PLACE
PROPER FIBER EQUIPMENT.
RECEIVED
SEP 12 2022
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
3550'
I
-- ---------
----- �} .
3550'
EXISTING 2" RISER ON ---
`f! POLE.
r 3550'
Y------ - ----
TRAFFIC CONTROL INSPECTION SHALL BE
REQUIRED WHENEVER WORK ZONE IS SET UP
/ X
ROAD
WORK X
AHEAD \
W201 ONE LANE X
ROAD
AHEAD
W20-4 BE X s
o.
PREPARED To
TO STOP sOO'
W20-7B
(OPTIONAL IF 40 MPH OR LESS)
W20-7A
RECEIVED
SEP 12 2022
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or
occurs during the permitted project.
I
BE N
PREPARED
PTO STOP/
SIGN SPACING = X (FEET) ( 1 )
RURAL HIGHWAYS 60 / 65 MPH
800"
RURAL ROADS 45155 MPH
500't
RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH
350'1
RURAL ROADS, URBAN ARTERIALS 25 / 30 MPH
RESIDENTIAL & BUSINESS DISTRICTS
200't (2)
URBAN STREETS 25 MPH OR LESS
100't (2)
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE
DESIGNATED.
(1) All spacing may be adjusted to accommodate intersections
and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
�go�\S?,n
W20-7A u �l
W20-76
(OPTIONAL IF 40 MPH OR LESS)
ROAD
WORK ONE LANE
AHEAD ROAD
W20-1 AHEAD
W20-4
FLAGGING STATION
N
SIGN LOCATION
®®®
CHANNELIZING DEVICES
PROTECTIVE VEHICLE
OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
UTILITIES MAY REQUIRE A SEPERATE PERMIT.
jW20-7A
111�
/BE
PREPARED
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
70
LENGTH (feet)
155
200
250
305
360
425
495
570
645
1730
TMA ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 Ibs.
HOST VEHICLE WEIGHT
> 22,000 Ibs.
< 45 MPH
1 45-55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100'
1 123'
172'
74'
100'
150'
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
CHANNELIZING DEVICE SPACING (FEET)
MPH
TAPER
TANGENT
50 / 65
40
80
35 / 45
30
60
25/30
20
40
W20-7B
(OPTIONAL IF 40 MPH OR LESS)
0 j W20 4
ONE LANE
ROAD
AHEAD W20-1
ROAD
WORK /
k AHEAD
6
NOTES
1. Night work requires additional roadway lighting at flagging stations.
2. Recommend extending channelizing device taper across shoulder. Channelizing devices
at flagger stations recommended.
3. Protective vehicle - may be a work vehicle strategically located to shield the work area.
4. For low -volume situations with short work zones on straight roadways where the flagger is visible
to road users approaching from both directions, a single flagger, positioned to be visible from both
directions may a used.
5. Extend the longitudinal buffer space to locate the taper in advance of a curve, if necessary.
ENGINEERING DIVISION
"OTED
OWNER/CONTRACTOR IS RESPONSIBLE FOR
EROSION CONTROLAND DRAINAGE _ �/ I� 13/06/2022
TRAFFIC CONTROL INSPECTION SHALL BE
REQUIRED WHENEVER WORK ZONE IS SET UP
Typical Very Short Duration Work Operation (Intersection Application)
WORK ZONE CONDITION (SEE CHAPTER 1.9.10) 3:
w
A - ALLOWED - CONSIDER USING A SPOTTER. RNOR Q
AXFAD
B - ALLOWED - SPOTTER RECOMMENDED co
CONSIDER ADDITIONAL WARNING SIGNS. RE
PREPARED
ro STOP
C - NOT ALLOWED - SEE TCP 14 & 15 FOR
ADDITIONAL WORK ZONE REQUIREMENTS. O
Flagg ers to temp hold traffic for overlash O
crossings. Traffic holds not to exceed 5
minutes per attempt; flaggers to relieve local
traffic between attempts.
N240TH ST SW WORK
i
AREA
RECEIVED
SEP 12 2022 i
ROAD W2 BE �7x
/
WORK PREPARED
AXEAD ro STOP
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
Spotter to assist any pedestrians through work zone
I Fr_FNn
® WORK VEHICLE W/ WARNING BEACON
¢ (LOCATE TO SHIELD WORK VEHICLE)
0 SPOTTER
SIGHT DISTANCE DATA
MINIMUM STOPPING SIGHT DISTANCE = S
SPEED LIMIT
25
30
35
40
45
50
55
60
65
70
MPH
DISTANCE
FEET
155
200
250
305
360
425
495
570
645
730
DISTANCES SHOWN ARE MINIMUMS, USE ADDITIONAL DISTANCE WHEN POSSIBLE.
GENERAL LIMITS OF
CHANNELIZED INTERSECTION
PREPARED WORK
ro sroP AKEAD
V-I
---------------------------------------------------------
238TH PL SW
"ROAD WORK AHEAD" signs to be
placed on all public road approaches to
work area or advance sign area.
NOTES:
1. Work vehicle w/beacon located in same quadrant as
work location.
2. Repeated access to work lane not allowed. see tcp
14 & 15 for work zone requirements - condition "C".
3. Restricted sight distance requires additional advance
warning devices or signs, see sight distance data chart.
4. Recommend working during red phase if signalized.
5. See chapter 1.9.10 - 1.9.11 for additional direction .
TYPICAL VERY SHORT DURATION WORK OPERATION
(INTERSECTION APPLICATION)
/ X
ROAD
WORK X
AHEAD
W201 ONE LANE X
ROAD
AHEAD
W2o-4 BE X so,
PREPARED
TO STOP
W20-7B
(OPTIONAL IF 40 MPH OR LESS)
W20-7A
RECEIVED
SEP 12 2022
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
TRAFFIC CONTROL INSPECTION SHALL BE
REQUIRED WHENEVER WORK ZONE IS SET UP
I
SIGN SPACING = X (FEET) ( 1 )
RURAL HIGHWAYS 60 / 65 MPH
800"
RURAL ROADS 45155 MPH
500't
RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH
350'1
RURAL ROADS, URBAN ARTERIALS 25 / 30 MPH
RESIDENTIAL & BUSINESS DISTRICTS
200't (2)
URBAN STREETS 25 MPH OR LESS
100't (2)
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE
DESIGNATED.
(1) All spacing may be adjusted to accommodate intersections
and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
W20-7A
BE
PREPARED
\STOP W2o-7B
(OPTIONAL IF 40 MPH OR LESS)
ROAD
WORK > ONE LANE
AHEAD ROAD
W20-1 AHEAD
W20-4
FLAGGING STATION
N
SIGN LOCATION
®®®
CHANNELIZING DEVICES
PROTECTIVE VEHICLE
jW20-7A
-T
BE
PR
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
1 45
1 50
1 55
60
65
11
LENGTH (feet)
155
200
250
305
360
425
495
570
645
730
TMA ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 Ibs.
HOST VEHICLE WEIGHT
> 22,000 Ibs.
< 45 MPH
1 45-55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100'
1 123'
172'
74' 1
100'
150'
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
CHANNELIZING DEVICE SPACING (FEET)
MPH
TAPER
TANGENT
50 / 65
40
80
35 / 45
30
60
25/30
20
40
W20-7B
(OPTIONAL IF 40 MPH OR LESS)
W20-4
ONE LANE
ROAD
AHEAD W20-1
ROAD
WORK
\k AHEAD
--ZZ!Z-Z
NOTES
1. Night work requires additional roadway lighting at flagging stations.
2. Recommend extending channelizing device taper across shoulder. Channelizing devices
at flagger stations recommended.
3. Protective vehicle - may be a work vehicle strategically located to shield the work area.
4. For low -volume situations with short work zones on straight roadways where the flagger is visible
to road users approaching from both directions, a single flagger, positioned to be visible from both
directions may a used.
5. Extend the longitudinal buffer space to locate the taper in advance of a curve, if necessary.
*Spotter to assist pedestrians through work zone
X
ROAD /
WORK X
AHEAD \
wzo 1 X
ONE LANE
ROAD
AHEAD
W20-4 BE X s
o.
PREPARED To
TO STOP sOO'
W20-7B
(OPTIONAL IF 40 MPH OR LESS)
W20-7A
RECEIVED
SEP 12 2022
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
j/
ROAD
WORK
AHEAD
w20-1
LEGEND
FLAGGING STATION
N SIGN LOCATION
®®® CHANNELIZING DEVICES
PROTECTIVE VEHICLE
I
BE N
PREPARED
TO STOP/
TRAFFIC CONTROL INSPECTION SHALL BE
REQUIRED WHENEVER WORK ZONE IS SET UP
SIGN SPACING = X (FEET) ( 1 )
RURAL HIGHWAYS 60 / 65 MPH
800"
RURAL ROADS 45155 MPH
500't
RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH
350'1
RURAL ROADS, URBAN ARTERIALS 25 / 30 MPH
RESIDENTIAL & BUSINESS DISTRICTS
200't (2)
URBAN STREETS 25 MPH OR LESS
100't (2)
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE
DESIGNATED.
(1) All spacing may be adjusted to accommodate intersections
and driveways.
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
W20-7A ' Y
W20-76
(OPTIONAL IF 40 MPH OR LESS)
jW20-7A
BE
PR
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
70
LENGTH (feet)
155
200
250
305
360
425
495
570
645
730
TMA ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 Ibs.
HOST VEHICLE WEIGHT
> 22,000 Ibs.
< 45 MPH
1 45-55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
100'
1 123'
172'
74'
100'
150'
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
CHANNELIZING DEVICE SPACING (FEET)
MPH
TAPER
TANGENT
50 / 65
40
80
35 / 45
30
60
25/30
20
40
W20-7B
(OPTIONAL IF 40 MPH OR LESS)
W20-4
ONE LANE
ROAD
AHEAD W20-1
ROAD
WORK
\k AHEAD
ONE LANE
ROAD
NOTES
AHEAD
W20-4
1.
Night work requires additional roadway lighting at flagging stations.
2.
Recommend extending channelizing device taper across shoulder. Channelizing devices
at flagger stations recommended.
3.
Protective vehicle - may be a work vehicle strategically located to shield the work area.
4.
For low -volume situations with short work zones on straight roadways where the flagger is visible
to road users approaching from both directions, a single flagger, positioned to be visible from both
directions may a used.
5.
Extend the longitudinal buffer space to locate the taper in advance of a curve, if necessary.
MAINTAIN TWO 11' TRAVEL LANES WHERE POSSIBLE ON 76TH