Building Permit (3)'S IDENTIAL
BLDG Permit
PERMIT NUM
of Edmonds
EdmondsCity
980201
� .
wwm
www.edmondswa.gov
Type: RESIDENTIAL BLDG
Owner/ Business: THOMAS CHUNG
Status: ISSUED
Subtype: NEW SINGLE FAMILY
Parcel No: 00745300000500 Site Address: 719 EDMONDS WAY EDMONDS,WA
98020-5125
Applied: 11/8/2018
Subdivision: 003900, 007453
Lot:
Issued: 6/22/2021
Fire Sprinklers: No Lot
Area: 35
Zoning: RS-6
Final:
Valuation: $312,810.76 Occupancy Type: R-3
Construction
Type: VB
Expiration Date: 6/17/2022
Code Edition: 2015 No. Stories: 2
# of Dwelling
Units: 1
Issued by: NED
Scope of Work: CHUNG NEW SINGLE FAMILY RESIDENCE LOT 3
WA State Contractor L & I #: MCLEOEL916PW
City of Edmonds Business License #: 602454996-001-0001
CONTACTS
NAME TYPE NAME
ADDRESS
PHONE
EMAIL
APPLICANT SUI H & LAI S/CHUNG STEPH 18321 3RD AVE SW, SHORELINE
(206)708-5538
THOMASCHUNG_1999@YAHOO.COM
CHUNG
WA 98177
8517 S 114TH
ST, SEATTLE WA
CONTRACTOR MCLEOD ENTERPRISES
LLC
98178
OWNER THOMAS CHUNG
18321 3RD AVE SW, SHORELINE
(206)708-5538
THOMASCHUNG_1999@YAHOO.COM
WA 98177
FEE
INFORMATION
DESCRIPTION
ACCOUNT
AMOUNT
PAID
PAID DATE RECEIPT#
2019 TRAFFIC IMPACT FEE
112.502.345.86.000.00
$6,249.14
$6,249.14
6/22/21
R13076
B-BUILDING PERMIT FEE
001.000.322.10.000.00
$2,378.00
$2,378.00
6/22/21
R13076
B-BUILDING PLAN REVIEW FEE
001.000.345.83.000.00
$1,937.00
$1,937.00
11/8/18
REC074750
B-MECHANICAL PERMIT FEE
001.000.322.10.000.00
$160.00
$160.00
6/22/21
R13076
B-PLUMBING PERMIT FEE
001.000.322.10.000.00
$334.00
$334.00
6/22/21
R13076
B-STATE BUILDING CODE
001.000.237.150
$6.50
$6.50
6/22/21
R13076
SURCHARGE
ENGINEERING INSPECTION FEE
001.000.341.82.000.00
$900.00
$900.00
6/22/21
R13076
PARK IMPACT ADMIN FEE
001.000.322.10.000.00
$50.00
$50.00
6/22/21
R13076
PARK IMPACT FEE
332.100.345.85.000.00
$2,734.05
$2,734.05
6/22/21
R13076
STORMWATER ENGINEER REVIEW
001.000.341.82.000.00
$65.00
$65.00
6/22/21
R13076
FEE
STORMWATER ENGINEER REVIEW
001.000.341.82.000.00
$130.00
$130.00
6/22/21
R13076
FEE
STORMWATER ENGINEER REVIEW
001.000.341.82.000.00
$240.00
$240.00
6/22/21
R13076
FEE
STORMWATER GENERAL FACILITY
422 000.379.00.000.00
$799.00
$799.00
6/22/21
R13076
CHARGE SFR UNDER 5000
TRANSPORTATION IMPACT ADMIN
001.000.341.82.000.00
$50.00
$50.00
6/22/21
R13076
FEE SFR
X-TECHNOLOGY FEE
001.000.321.99.100.00
$35.00
$35.00
6/22/21
R13076
TOTALS:
$16,067.69
$16,067.69
Printed: Tuesday, June 22, 2021 1:57:34 PM 1 of 4
'IDENTIAL BLDG PermitCity
• • • • PERMITNUM
121 98020 1 .
www.edmondswa.gov
CONDITIONS
CONDITION TYPE
STATUS NOTES
48 HRS NOTICE-ENGR FINAL
FOR
48 Hours notice is required when requesting your FINAL engineering inspection.
NFORMATION
Contractor/Owner shall be responsible for repair/replacement of all damage to utilities
DAMAGE TO FRONTAGE
FOR
and/or frontage improvements in city right of way per city standards that is caused by or
IMPROVEMENTS
INFORMATION
occurs during the permitted project.
Damage to Frontage
Applicant shall repair/replace all damage to utilities or frontage improvements in City
Improvments
right-of-way per City standards that is caused by or occurs during the permitted project.
Electrical Permit
Obtain Electrical Permit from State Department of Labor & Industries. 425-290-1309
ENG INSPECTIONS
FOR
INFORMATION
ESC REQUIRED
FOR
MAINTAIN EROSION & SEDIMENT CONTROL PER CITY STANDARDS
NFORMATION
In addition to the required pressure/relief valve, an approved listed expansion tank shall
Expansion Tank
be installed on all hot water tanks. Per UPC 608.
Approval of this foundation design is conditional subject to inspection of existing site soil
conditions.
Foundation Bearing
Retaining Walls must be designed and constructed to resist the lateral pressure of the
retained material.
Provisions must be made for the control and drainage of surface water around buildings.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests,
agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its
Hold Harmless
officials, employees, and agents from any and all claims for damages of whatever nature,
arising directly or indirectly from the issuance for this permit. Issuance of this permit shall
not be deemed to modify, waive or reduce any requirements of any City ordinance nor
limit in any way the City's ability to enforce any ordinance provision.
Hose Bibbs (exterior faucets) are required to have a permanently affixed anti -siphon
Hose Bibbs
device installed.
INSPECTION PRIOR TO BACKFILL
FOR
Call for all required inspections. All work shall be inspected prior to backfill.
NFORMATION
Lot Lines Staked
Lot line stakes must be in place at the time of foundation/setback inspection.
Installation, use and maintenance of equipment and components shall be per
Manufacturer's Specs
manufacturer's specifications, installation instructions, and applicable state codes.
Provide manufacture's installation instructions on site for Building Inspector.
Maximum Height 25 feet. The agent/contractor shall set up the equipment; establish the
datum point and the point of average grade. Call for inspection to verify. These items
Maximum Height
must be consistent with the approved plan. If the proposed height of a building (as
shown on the plans) is within 12 inches of the maximum height permitted for the zone an
elevation survey is required.
Final approval on a project or final occupancy approval must be granted by the Building
Occupancy
Official prior to use or occupancy of the building or structure. Check the job card for all
required City inspections including final project approval and final occupancy inspections.
OVWSD WATER LINE/METER
FOR
This property falls within the Olympic View Water and Sewer District. Contact Olympic
INFORMATION
View for specific water line and/or water meter information.
Printed: Tuesday, June 22, 2021 1:57:34 PM 2 of 4
MIDENTIAL BLDG Permit
PERMIT NU
City of Edmonds
121 . 98020 1 .
www.edmondswa.gov •
Any request for alternate design, modification, variance or other administrative deviation
(hereinafter "variance") from adopted codes, ordinances or policies must be specifically
requested in writing and be called out and identified. Processing fees for such request
shall be established by Council and shall be paid upon submittal and are non-refundable.
Permit Disclaimer
Approval of any plat or plan containing provisions which do not comply with city code
and for which a variance has not been specifically identified, requested and considered
by the appropriate city official in accordance with the appropriate provision of city code
or state law does not approve any items not to code specification.
PRV Required
Pursuant to UPC 608 a pressure regulator valve (PRV) shall be installed near the water
shutoff.
FOR
Maintain a minimum of 2 ft shy distance from structure to paved surface as required per
SHY DISTANCE
INFORMATION
approved plans.
Sound/Noise originating from temporary construction sites as a result of construction
activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of
Sound/Noise
7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction
sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has
been granted pursuant to ECC 5.30.120.
STORM COVENANT
FOR
A stormwater covenant shall be approved for recording prior to project final approval.
NFORMATION
UNDERGROUND UTILITY
FOR
Call for locates of underground utilities prior to any excavation.
LOCATES
INFORMATION
All new, extended, re -built or relocated electrical utility and/or service shall be placed
Underground Wiring
underground.
Type B or L vent connectors required on fuel -burning appliances passing through
Vent Connectors
unheated spaces. Per IMC 803.2
City approved plastic piping may be used in water service piping provided that where
metal water service piping is used for electrical grounding purposes, replacement piping
Water Service Piping
shall be of like materials (UPC 604.8). A state electrical permit and inspection is required
if electrical grounding is altered, removed, improved, or added. Contact State Dept. of
Labor & Industries Electrical Division at 425-290-1400.
Pursuant to UPC 605.2 a water service shutoff shall be installed on the water line as it
Water Service Shutoff
enters the building.
Installer shall provide the manufacturer's installation, operating instructions, and a whole
Whole House Fan
house ventilation system operation description. A label shall be affixed to the whole
house timer control that reads "Whole House Ventilation" (see operating instructions).
INSPECTIONS
- Schedule Online
at: https://Inspection.MvBuildingPermit.com
COMPLETED
SEQID
INSPECTION TYPE
INSPECTOR
RESULT
NOTES
DATE
E-3 STRM FOOTING DRAIN
E-3 STRM MGMT FACILITY
E-3 STRM TIGHTLINE
E-4 WATER SERVICE LINE
B-4 DRYWALL FASTENING
B-2 FOOTINGS
B-2 FOUNDATION WALL
B-4 FRAMING
Printed: Tuesday, June 22, 2021 1:57:34 PM 3 of 4
IDENTIAL BLDG Permit
City of • • • PERMITNUM
lli'S
-98020 1 � .
wm . •.
B-3 GAS PIPING TEST
B-4 HEIGHT VERIFICATION
B-5 INSULATION ENERGY
B-3 MECH ROUGH IN
B-3 PLUMB ROUGH IN
B-3 ROOF SHEATHING
B-2 SLAB INSULATION
B-3 UNDERFLR FRAMING
A-1 BUILDING PRECON
B-1 SETBACKS
B-3 STUCCO
B-4 INTERIOR SHEAR
X-3 BUILDING FINAL"
X-2 ENGINEERING FINAL
B-7 BUILDING OTHER INSP
E-5 DRIVEWAY SLOPE
A-1 TESC AND MOBILIZE
E-3 STRM CONVEYANCE
E-3 STRM PERVIOUS
SURFACES
E-3 STRM COVENANT
E-5 ENG SPECIAL INSPECTION
Printed: Tuesday, June 22, 2021 1:57:34 PM 4 of 4