APPROVED PLN BLD2022-1600+Mechanical_Plan+11.21.2022_8.52.51_AM+3230337ABBREVIATIONS GENERAL AD ACCESS DOOR ADD'L ADDITIONAL AF AIR FOIL AFF ABOVE FINISHED FLOOR AFR ABOVE FINISHED ROOF ALT ALTITUDE OR ALTERNATE AMP AMPERE AP ACCESS PANEL APD AIR PRESSURE DROP ARCH ARCHITECT AS AIR STREAM ATC AUTOMATIC TEMPERATURE CONTROL ATM ATMOSPHERE AVE AVERAGE BHP BRAKE HORSEPOWER BLDG BUILDING BOD BOTTOM OF DUCT BTU BRITISH THERMAL UNIT BTUH BTU PER HOUR CENT CENTRIFUGAL CFM CUBIC FEET PER MINUTE CLG CEILING OR COOLING CO CARBON MONOXIDE COL COLUMN CONN CONNECTION CONTR CONTRACTOR D DRAIN OR DEPTH DB DRY BULB TEMPERATURE DEG DEGREE DDC DIRECT DIGITAL CONTROL DIA DIAMETER DIM DIMENSION DN DOWN DP DIFFERENTIAL PRESSURE EA EACH OR EXHAUST AIR EAT ENTERING AIR TEMPERATURE EFF EFFICIENCY ELEC ELECTRICAL ELEV ELEVATION ENT ENTER ESP EXTERNAL STATIC PRESSURE EWT ENTERING WATER TEMPERATURE EXH EXHAUST EXIST EXISTING EXT EXTERNAL EXP EXPANSION F FAHRENHEIT FA FREE AREA FC FLEXIBLE CONNECTION FLA FULL LOAD AMPS FLEX FLEXIBLE FLRDR FLOOR DRAIN FO FLAT OVAL FPM FEET PER MINUTE FPS FEET PER SECOND FS FLOW SWITCH FT FEET GA GAUGE GAL GALLONS GALV GALVANIZED GC GENERAL CONTRACTOR GPH GALLONS PER HOUR GPM GALLONS PER MINUTE GIRD GRADE GWB GYPSUM WALL BOARD HGT HEIGHT HP HORSEPOWER OR HIGH POINT HR HOUR HTG HEATING HZ HERTZ (FREQUENCY, CYCLES PER SECOND) ID INSIDE DIAMETER IN INCHES :Z►��-11I[O1,N0%110I L LENGTH LAT LEAVING AIR TEMPERATURE LB POUND LF LINEAR FEET LP LOW POINT LRA LOCKED ROTOR AMPS LUVR LOUVER LVG LEAVING LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MBH THOUSAND BTUH MCA MINIMUM CIRCUIT AMPS MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM N/A NOT APPLICABLE NC NORMALLY CLOSED OR NOISE CRITERIA NIC NOT IN CONTRACT NO NORMALLY OPEN No NUMBER NOM NOMINAL NTS NOT TO SCALE OA OUTSIDE AIR OAI OUTSIDE AIR INTAKE OD OUTSIDE DIAMETER OV OUTLET VELOCITY PD PRESSURE DROP PH PHASE PBG PLUMBING POC POINT OF CONNECTION TO EXISTING POS PROVIDED BY OTHER SECTION PSI POUNDS PER SQUARE INCH QTY QUANTITY R RADIUS RA RETURN AIR RET RETURN REQ'D REQUIRED RH RELATIVE HUMIDITY RLA RUNNING LOAD AMPS RLF RELIEF RM ROOM RPM REVOLUTIONS PER MINUTE SCH SCHEDULE SCR SCREEN SDET SMOKE DETECTOR SEN SENSIBLE SHC SENSIBLE HEAT CAPACITY SP STATIC PRESSURE SPECS SPECIFICATIONS SF SQUAREFEET SS STAINLESS STEEL STL STEEL SUP SUPPLY T TEMPERATURE TA THROWAWAY TEFC TOTALLY ENCLOSED FAN COOLED TEMP TEMPERATURE TSTAT THERMOSTAT TON 12,000 BTUH COOLING CAPACITY TOT TOTAL TYP TYPICAL V VOLTS (ELECTRICAL) VEL VELOCITY W WIDTH OR WATT W/ WITH WB WET BULB TEMPERATURE WMS WIRE METAL SCREEN W/O WITHOUT WPD WATER PRESSURE DROP WTD WATER TEMPERATURE DIFFERENCE X EXISTING EQUIPMENT TO BE REMOVED XM EXISTING EQUIPMENT TO REMAIN XN NEW LOCATION OF RELOCATED EQUIPMENT XR EXISTING EQUIPMENT TO BE RELOCATED CHILLED WATER CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY DUCT ACD AUTOMATIC CONTROL DAMPER AFMS AIR FLOW MEASURING STATION AL ACOUSTICAL DUCT LINER BDD BACKDRAFT DAMPER BOD BOTTOM OF DUCT CD CEILING DIFFUSER DIFF DIFFUSER FBD FLAT BOTTOM DUCT FO FLAT OVAL LD LINEAR DIFFUSER MUA MAKE-UP AIR OED OPEN END DUCT PAD PRIMARY AIR DAMPER RA RETURN AIR SA SUPPLY AIR SL SOUND LINING SR SUPPLY REGISTER TA THROW AWAY OR TRANSFER AIR TG TRANSFER GRILLE TOD TOP OF DUCT TR TRANSFER TSP TOTAL STATIC PRESSURE (IN. WG) TV TURNING VANES VD VOLUME DAMPER AF AIR FILTER OR AIR FOIL DDC DIRECT DIGITAL CONTROL EHC ELECTRICAL HEATING COIL FPB FAN POWERED BOX FCU FAN COIL UNIT RHC REHEAT COIL SF SUPPLY FAN TD TRANSFER DUCT PIPING AAV AUTOMATIC AIR VENT ACV AUTOMATIC CONTROL VALVE ATV ATMOSPHERIC VENT BOP BOTTOM OF PIPE CO CLEAN -OUT DOV DRAIN -OFF VALVE FOB FLAT ON BOTTOM REDUCER FOT FLAT ON TOP REDUCER MAV MANUAL AIR VENT TOP TOP OF PIPE V VENT CONTROLS ACD AUTOMATIC CONTROL DAMPER ACV AUTOMATIC CONTROL VALVE AFMS AIR FLOW MEASURING STATION ALM ALARM CT CURRENT TRANSFORMER (STATUS FEEDBACK) DAT DISCHARGE AIR TEMPERATURE SENSOR DDC DIRECT DIGITAL CONTROL LAT LEAVING AIR TEMPERATURE SENSOR MAT MIXED AIR TEMPERATURE SENSOR OSA OUTSIDE AIR OS OCCUPANCY SENSOR (CO2) NC NORMALLY CLOSED (ON LOSS OF POWER) NO NORMALLY OPEN (ON LOSS OF POWER) SD SMOKE DETECTOR SP STATIC PRESSURE SENSOR SPD SPEED CONTROL S/S START/STOP T TEMPERATURE SENSOR/THERMOSTAT TR TRANSFORMER City Of Edmonds Building Department Work MECHANICAL Address 326 ADMIRAL WAY ---------------------------------- - - - - Owner PORT OF EDMONDS Approved Date 12/07/2022 ---------- Building Official Eri & C4rte-r Permit Number; BLD2022-1600 DUCTWORK W D RECTANGULAR RETURN/EXHAUST W D RECTANGULAR DUCT 10x6 DUCT, W=WIDTH, D=DEPTH 10x6 AS VIEWED ROUND DUCT ROUND RETURN/EXHAUST DUCT DIA (DIA=INSIDE DIAMETER) 10"QJ FLAT OVAL DUCT 10x6 FO ROUND SUPPLY DUCT UP STANDARD RADIUS ELBOW (R = W) ROUND SUPPLY DUCT DOWN �, ;•: SUPPLY/RETURN/EXHAUST R < FW� RECT. SUPPLY DUCT UP FULL LENGTH SPLITTER VANES � RECT. SUPPLY DUCT DOWN (Rc W) �R SUPPLY/RETURN/EXHAUST 1Wi ROUND RETURN DUCT UP ROUND RETURN DUCT DOWN SPLIT TAKE -OFF RETURN DUCT UP RETURN DUCT DOWN RECTANGULAR WYE SUPPLY ROUND EXHAUST DUCT UP ROUND EXHAUST DUCT DOWN AD RECT. EXHAUST DUCT UP FIRE DAMPER ACCESS DOOR AD RECT. EXHAUST DUCT DOWN CHANGE OF ELEVATION RECTANGULAR DUCT TO ROUND 6" 0 10x6 (R)RISE OR (D)DROP SUPPLY/RETURN/EXHAUST --► R/D CEILING DUCT MOUNTED I> 45° TAP TAKE -OFF DIFFUSER/GRILLE 45° TAKE -OFF VD TRANSITION TO ROUND TAKE -OFF TO DIFFUSER/GRILLE W/ FLEX DUCT y VD 45° TAKEOFF 90° RECT. TAP TAKE -OFF 1 TE SQUARE TO ROUND BELLMOUTH CONNECTION CONNECTION CEILING DUCT MOUNTED 1 �TVD DIFFUSER/GRILLE CONVERGE RETURN/EXHAUST W/45° TAKE -OFFS ACOUSTICALLY LINED DUCT EXTERNALLY WRAPPED DUCT OPEN END DUCT W/ 1/2"x1/2" WMS i BARE DUCT FIRE DAMPER FD FIRE -SMOKE DAMPER FSD FLEXIBLE DUCT (DOUBLE LINE) FLEXIBLE DUCT (SINGLE LINE) CEILING RADIATION DAMPER CRD AIR DISTRIBUTION TERMINALS SUPPLY DIFFUSER TYPE: CD-1 AIR TERMINAL CALLOUT NECK SIZE: 8 0 RETURN GRILLE 150 CFM: TYP 2 EXHAUST AIR FLOW '',- ► EXHAUST GRILLE SUPPLY AND RETURN CEILING R.A. SOUND BOOT GOOSENECK RELIEF/EXHAUST HOOD i it DUCT MOUNTED "BULLS EYE"�� DIFFUSER GOOSENECK INTAKE AIR HOODIIIH I MODUBLOC DIFFUSER 1AA] I-M LINEAR SLOT DIFFUSER DOUBLE DEFLECTION WALL MOUNTED DOUBLE DEFLECTION BRANCH SUPPLY DIFFUSER _A0. MOUNTED SUPPLY DIFFUSER l 1 CONTROLS LEGEND DT THERMOSTAT OS OCCUPANCY SENSOR (CO2 / MOTION) O SPACE TEMPERATURE SENSOR O AVERAGING SPACE TEMPERATURE SENSOR MOTORIZED DAMPER SD DUCT MOUNTED SMOKE DETECTOR DUCT MOUNTED PRESSURE SENSOR DIFFERENTIAL PRESSURE SENSOR 24 MODULATING DAMPER ACTUATOR G2-POSITION DAMPER ACTUATOR BACKDRAFT DAMPER OAT DAT MAT SP H -ET@ 0 0 00. OUTSIDE AIR TEMP SENSOR DISCHARGE AIR TEMP SENSOR MIXED AIR TEMP SENSOR DUCT STATIC PRESSURE SENSOR HUMIDISTAT (SPACE MOUNT) HUMIDISTAT (DUCT MOUNT) DUCT MOUNTED SAIL SWITCH ROUND CONTROL DAMPER Idx��_1►[e1�J�_CZK�1���:Z�]�U_1► 1��:7 BAROMETRIC RELIEF DAMPER DIAGRAM EQUIPMENT SYMBOLS EQUIPMENT CALLLOUT EQ-X FAN POWERED FILTER BANK VAV TERMINAL FAN POWERED VAV TERMINAL WITH REHEAT COIL REHEAT MODULE xC SINGLE DUCT COOLING COIL VAV TERMINAL OUTDOOR CONDENSING DUAL DUCT UNIT OR HEAT PUMP VAV TERMINAL _ 2-WAY AUTOMATIC CONTROL VALVE (MODULATING) PACKAGED ROOFTOP UNIT - - y 3-WAY AUTOMATIC CONTROL VALVE (MODULATING) REQUIRED CLEARANCE AREA WATER SOURCE HEAT PUMP WITH SIDE RETURN GOOSENECK STYLE ROOF HOOD WATER SOURCE HEAT PUMP WITH END RETURN "CHINA CAP" STYLE ROOF HOOD FAN COIL UNIT f4— F--� FLAT STYLE ROOF HOOD I I I IL PACKAGED TERMINAL �® AC OR HEAT PUMP PERIMETER STEAM HEAT O CONVECTOR UNIT VRF DUCTED FAN COIL UNIT DUCTLESS SPLIT WALL MOUNTED FAN COIL UNIT VRF HEAT RECOVERY MODULE VRF HEAT PUMP UNIT CEILING MOUNTED EXHAUSTFAN INLINE EXHAUST FAN gal T PT 4 AV ^MV �co PIPING LEGEND BALL VALVE BUTTERFLY VALVE HOSE END BALL VALVE WITH CAP AND CHAIN PLUG VALVE 2-WAY MODULATING PRESSURE INDEPENDENT ACV AUTOMATIC FLOW LIMITING VALVE (PRESSURE INDEPENDENT) COMBINATION FLOW METER/SHUT-OFF/BALANCING VALVE (CIRCUIT SETTER) UNION BLIND FLANGE PIPE - CAPPED PRESSURE/THERMOMETER WELL AIR VENT - AUTOMATIC AIR VENT - MANUAL DIRECTION OF FLOW FLEXIBLE CONNECTOR PIPE - DOWN PIPE - UP CLEANOUT FOR CONDENSATE DRAIN PIPE BREAK (SINGLE LINE) BALL VALVE REDUCER ALL WORK SUBJECT ' TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED LANS MUST BE ON JOB SITE Ln 0 Ln I N � � 0 o w z z 0 _ 0 0 � w w N N r 1E U) Ll O U Q O `CY)° 65 ~ z (0 rZ Q0 r­ O U CO N O N ATM Ney Q U_ LL z Q U) _ � 00 U LU �M Lo Q w 0 O .� W J cy) m W° C� G U � O W V U > C:) 00 O W UQ� In — Uj z Q � 0 > W z<O 0N2i N oMo W RECEIVES Nov 21 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SYMBOLS AND LEGENDS SHEET NO. M-1.0 REPLACEMENT ROOFTOP HVAC UNIT SCHEDULE MARK MANUFACTURER MODEL DESCRIPTION CFM MIN. OSA SP MOTOR HP CLG CPY SEER HTG INPUT HTG OUTPUT AFUE VOLTAGE MCA MOCP WEIGHT REMARKS RTU-1 YORK ZJ036N04P2AAA1 EXISTING 3-TON ROOFTOP HEAT PUMP UNIT 1,200 0.6" 1.5 38.0 MBH 13.0 50.0 MBH 40.0 MBH 80% 208-60-3 23.5 AMPS 30.0 AMPS 756 LBS NOTES 1, 2, 3, 4 RTU-2 YORK D2NZ024N05606 EXISTING 2-TON ROOFTOP HEAT PUMP UNIT 800 0.76" 0.5 22.8 MBH 13.2 70.0 MBH 56.0 MBH 80% 208-60-1 21.3 AMPS 30.0 AMPS 514 LBS NOTES 1, 2, 3, 4 RTU-3 YORK D2NZ024N05606 EXISTING 2-TON ROOFTOP HEAT PUMP UNIT 800 0.76" 0.5 22.8 MBH 13.2 70.0 MBH 56.0 MBH 1 80% 1 208-60-1 1 21.3 AMPS 30.0 AMPS 514 LBS NOTES 1, 2, 3, 4 RTU-4 YORK ZJ036N04P2AAA1 EXISTING 3-TON ROOFTOP HEAT PUMP UNIT 1,200 0.6" 1.5 38.0 MBH 13.0 50.0 MBH 40.0 MBH 1 80% 1 208-60-3 1 23.5 AMPS 30.0 AMPS 756 LBS NOTES 1, 2, 3, 4 RTU-6 YORK ZJ048N06P2AAA1 EXISTING 4-TON ROOFTOP HEAT PUMP UNIT 1,600 0.6" 1.5 49.0 MBH 13.0 75.0 MBH 60.0 MBH 1 80% 1 208-60-3 1 27.5 AMPS 30.0 AMPS 776 LBS NOTES 1, 2, 3, 4 NOTES: 1. INCLUDES 100% ECONOMIZER, BAROMETRIC RELIEF, AND STANDARD ROOF CURB 2. INCLUDES ENERTEC BAS DDC CONTROLS, UNIT CONTROLLER MOUNTED IN UNIT, TEMPERATURE SENSOR LOCATIONS AS SHOWN ON PLANS 3. FACTORY CHARGED WITH R410A 4. ALL POWER WIRING AND DISCONNECTS BY ELECTRICAL CONTRACTOR SPLIT SYSTEM SCHEDULE NOMINAL RATED TOTAL MIN MARK MANUFACTURER MODEL DESCRIPTION AREA SERVED ESP SEER HSPF COP VOLTAGE MCA MOCP WEIGHT REMARKS CLG CPY CLG CPY CFM OSA AC-1 MITSUBISHI PEAD-A30AA7 NEW HORIZONTAL DUCTED AIR CONDITIONER SERVER 211 700 - 0. 15" 208-60-1 2.7 15 69 LBS NOTES 2, 3 CU-1 MITSUBISHI PUZ-A30NKA7 NEW CONDENSER UNIT 30.0 MBH 30.0 MBH 19.1 1 10.0 1 4.0 208-60-1 19 30 151 LBS NOTE 1 NOTES: 1. ECONOMIZER EXEMPT PER 2018 SEC C403.3 EXCEPTION 10, EQUIPMENT USED TO COOL ANY DEDICATED SERVER ROOM IN COMPLIANCE WITH OPTION A. 2. RUN CONDENSATE DRAIN PIPING TO AN APPROVED, AIR GAPPED, OBSERVABLE POINT OF CONNECTION WITH BUILDING SANITARY WASTE SYSTEM. 3. CONTROL VIA FACTORY WIRED MA CONTROLLER (PAR-33MAA) EXHAUST FAN SCHEDULE MARK IMANUFACTURERI MODEL I DESCRIPTION DESIGN CFM TSP I AREA SERVED 1INPUTPOWERI VOLTAGE I WEIGHT I REMARKS EF-1 I FANTECH I FG-8-EC I NEW INLINE EXHAUST FAN 1 350 0.2" 1 BREAK AREA 223 1 71 WATTS 1 120-60-1 1 8.4 LBS I NOTES 1, 2, 3 NOTES: 1. INTERLOCK WITH WALL SWITCH, WIRED BY ELECTRICAL CONTRACTOR 2. PROVIDE WITH SPEED CONTROLLER FOR BALANCING 3. PROVIDE WITH ECM PER 2018 WSEC AIR TERMINAL SCHEDULE MARK MANUFACTURER MODEL DESCRIPTION NECK SIZE QTY REMARKS CD-1 PRICE SMCD 24"x24" T-BAR MOUNTED MODULAR CORE DIRECTIONAL DIFFUSER AS INDICATED 3 NONE RG-1 PRICE 80 12"x24" T-BAR MOUNTED EGG CRATE RETURN GRILLE 12"x24" 6 NONE EG-1 PRICE 80FF 24"x24" T-BAR MOUNTED EGG CRATE EXHAUST FILTER GRILLE 8"0 1 NONE GENERAL HVAC NOTES 1. MECHANICAL DESIGN, INSTALLATION & COORDINATION SHALL COMPLY WITH THE FOLLOWING CODES: A. INTERNATIONAL MECHANICAL CODE (IMC) 2018 B. WASHINGTON STATE ENERGY CODE (WSEC) 2018 C. WASHINGTON STATE INDOOR AIR QUALITY CODE (WSIAQC) 2012 2. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. ADDITIONAL MECHANICAL NOTES MAY BE INDICATED ON EACH MECHANICAL DRAWING. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 3. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING, LOUVERS, CONCRETE EQUIPMENT PADS FLASHING DETAILS, ETC. 4. REFER TO ARCHITECTURAL DRAWING FOR ROOM ELEVATIONS. LOCATE MECHANICAL DEVICES SUCH AS TEMPERATURE SENSORS, HUMIDISTATS, PANELS, ETC. SO THAT THEY DO NOT CONFLICT WITH GENERAL CONSTRUCTION (WAINSCOT, DOOR HARDWARE, ETC.) NOR WITH ELECTRICAL SYSTEM (LIGHT SWITCHES, SPEAKERS, OUTLETS, ETC.). 5. MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLS AND DIFFUSERS. FIELD COORDINATE ACTUAL LOCATIONS BY REFERRING TO ARCHITECTURAL DRAWINGS, REFLECTED CEILING PLANS, AND OTHER CEILING OR SURFACE MOUNTED DEVICES PLANS. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE INDICATED ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT INDICATED ON ARCHITECTURAL DRAWINGS, OBTAIN DIRECTION FROM ARCHITECT PRIOR TO INSTALLATION. 6. GENERALLY DUCTWORK PLANNED TO BE TIGHT TO STRUCTURE WITH PIPING BELOW DUCTWORK AND BETWEEN LIGHT FIXTURES. ADJUST AS NECESSARY. 7. COORDINATE LOCATIONS OF MECHANICAL EQUIPMENT AND DUCTWORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND SERVICE ACCESS DUE TO EQUIPMENT MAINTENANCE. 8. ARRANGE HVAC EQUIPMENT SO THAT ACCESS CLEARANCES INDICATED BY DRAWINGS, REQUIRED BY CODES, AND RECOMMENDED BY MANUFACTURER ARE PROVIDED. 9. WHERE NECESSARY, PROVIDE ACCESS PANELS/DOORS IN DUCTWORK AS INDICATED FOR INSPECTION AND MAINTENANCE FOR ALL SMOKE/FIRE DAMPERS. 10. GENERAL CONTRACTOR SHALL PROVIDE ACCESS TO FIRE AND/OR COMBINATION FIRE/SMOKE DAMPERS THROUGH ACCESS DOORS IN HARD CEILINGS AND WALLS. WHERE ACCESS DOORS PENETRATE FIRE RATED SYSTEMS THEY SHALL BE RATED IN ACCORDANCE WITH IBC REQUIREMENTS. 11. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL CHARACTERISTICS OF MECHANICAL EQUIPMENT (VOLTAGES, ETC). 12. ELECTRICAL CHARACTERISTICS OF LISTED EQUIPMENT SHALL BE VERIFIED BY CONTRACTOR DURING SUBMITTAL PROCESS. ANY ELECTRICAL CHARACTERISTICS THAT DEVIATE FROM THOSE LISTED SHALL BE IDENTIFIED BY THE CONTRACTOR, SUBMITTED TO THE ENGINEER FOR APPROVAL AND COORDINATED WITH DIVISION 16 (OR DIVISION 26) PRIOR TO INSTALLATION OF EQUIPMENT AS REQUIRED TO PROPERLY SERVE EQUIPMENT. 13. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW OFFSETS WHICH MAY BE REQUIRED. PROVIDE OFFSETS AS REQUIRED AT NO ADDITIONAL COST. 14. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS, VALVES, ETC. FLOOR PLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE ROUTING ONLY. 15. DUCTS AND PIPES INDICATED WITHOUT DIMENSIONS SHALL BE SIZED PER PRECEDING UPSTREAM DUCT AND PIPE SECTIONS. 16. DUCTWORK SIZES SHOWN ARE CLEAR INSIDE DIMENSION. 17. PROVIDE FABRICATED STEEL MEMBER SUPPORTS AS REQUIRED BY MANUFACTURER'S INSTALLATION INSTRUCTIONS, AS INDICATED ON DRAWINGS, OR IN SPECIFICATIONS FOR INSTALLATION OF EQUIPMENT. REQUIRED STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 18. IF REQUIRED FOR INSTALLATION OF PIPES, DUCTS, AND EQUIPMENT, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO MEET SUPPORT REACTIONS (FORCES, MOMENTS, AND DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. 19. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS, AND SHEAR WALLS, UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY THE STRUCTURAL ENGINEER. 20. ON ALL EXTENDED PLENUMS CONNECTED TO A DISCHARGE OUTLET ON A SUPPLY AIR DEVICE SUCH AS A WATER SOURCE HEAT PUMP, FAN COIL UNIT, FAN POWERED VAV TERMINAL, PROVIDE 1" THICK INTERIOR ACOUSTICAL LINER IN THE FIRST 4 FT. OF LENGTH. NO TAP -INS SHALL OCCUR IN THIS SECTION. 21. PROVIDE DUCT LINING FOR THE FOLLOWING DUCTWORK: A. ALL AIR TRANSFER DUCTS AND CEILING RELIEF GRILLS B. ALL MIXED AIR AND EXHAUST AIR PLENUMS C. ALL OUTDOOR AIR DUCTS OR PLENUMS 22. PROVIDE A VOLUME DAMPER FOR EACH SUPPLY BRANCH, RETURN BRANCH (DUCTED ONLY), & EXHAUST BRANCH WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH THE BRANCH, AND ELSEWHERE AS NOTED ON THE DRAWINGS OR IN SPECIFICATIONS. 23. DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED ON SMACNA STANDARDS. 24. REFER TO WASHINGTON STATE NREC COMPLIANCE REQUIREMENTS ON DRAWING SCHEDULE SHEETS FOR ADDITIONAL MECHANICAL PROVISIONS. 25. PROVIDE ECONOMIZERS IN ACCORDANCE WITH WSEC (2018). 26. SEAL DUCT AND PLENUM IN ACCORDANCE WITH WSEC (2018). 27. BALANCE HVAC SYSTEM IN ACCORDANCE WITH WSEC (2018). 28. COMMISSION AND COMPLETE MECHANICAL SYSTEMS IN ACCORDANCE WITH WSEC (2018). 29. PROVIDE COMPLETION/RECORD DRAWINGS IN ACCORDANCE WITH WSEC (2018). 30. INSULATE DUCT AND PLENUM IN ACCORDANCE WITH WSEC (2018). 31. INSULATE PIPING IN ACCORDANCE WITH WSEC (2018). 32. PROVIDE THERMOSTATIC CONTROLS IN ACCORDANCE WITH WSEC (2018). 33. ENSURE SETPOINT OVERLAP RESTRICTION IN ACCORDANCE WITH WSEC (2018). 34. PROVIDE THERMOSTATIC SETBACK CAPABILITIES IN ACCORDANCE WITH WSEC (2018). 35. EQUIP SHUTOFF DAMPER CONTROLS IN ACCORDANCE WITH WSEC (2018). 36. ENSURE VENTILATION IN ACCORDANCE WITH WSEC (2018). 37. PROVIDE DEMAND CONTROL VENTILATION IN ACCORDANCE WITH WSEC (2018). 38. PROVIDE OCCUPANCY SENSORS IN ACCORDANCE WITH WSEC (2018). 39. ENSURE ELECTRIC MOTOR EFFICIENCY IN ACCORDANCE WITH WSEC (2018). 40. PROVIDE SINGLE DUCT VARIABLE AIR VOLUME (VAV) SYSTEMS WITH TERMINAL DEVICES IN ACCORDANCE WITH WSEC (2018). 41. PROVIDE DUAL DUCT AND MIXING VAV SYSTEMS WITH TERMINAL DEVICES IN ACCORDANCE WITH WSEC (2018). 42. ENSURE WORK ACCESS CLEARANCE FOR ALL MECHANICAL ELECTRICAL PANELS IS IN ACCORDANCE TO THE NEC (2018). 43. ALL EQUIPMENT, DUCT, AND OTHER ITEMS INSTALLED WITHIN THE RETURN PLENUM MUST BE NONCOMBUSTIBLE, OR SHALL BE LISTED AND LABELED AS HAVING A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE TO ASTM E 84 OR UL 723. 44. WHERE MULTIPLE AIR -HANDLING SYSTEMS SHARE COMMON SUPPLY OR RETURN AIR DUCTS OR PLENUMS WITH A COMBINED DESIGN CAPACITY GREATER THAN 2,000 CFM (0.9 M3/S), THE RETURN AIR SYSTEM SHALL BE PROVIDED WITH SMOKE DETECTORS IN ACCORDANCE WITH 2O18 IMC 606.2.1. VICINITY MAP :e Stau raril Edmonds SPaEood • 8S 326 Admiral Way, Edmonds, WA 98420 a� Jaeabsens Marine - - Scat dial-f �`tr r Ed les _ " Puge1 Sound, dt de�ir Yacht l3ervlcv Anthony's r fl Edmonds f 9 Puget Sound t P� l NORTH atertront ark - ffr� ine � e� etato T.Dp Pot D7uglinuts Edmonds fishing pier on rv`rater sports Di.�F shop4 +' Cascadla Art Museum E 3 Hou`s •RIZrOig tl W Dayton St OUmpaSS 0i: Channel Marker Animal Dermatology Service 4 19 H a rbGr Sq ua re Den€al Saldsh Sea Brewing C-1 €#oathous: Taproom ?H rbor hletIq lub are Athletic Eub Elmo: m CL Edmonds o Marsh rL l N 1 I �e SHEET INDEX SHEET NUMBER DESCRIPTION M-1.0 SYMBOLS AND LEGENDS M-1.1 SCHEDULES AND PROJECT INFORMATION M-2.1 PARTIAL 2ND FLOOR HVAC PLANS LEGAL DESCRIPTION SEC 23 TWP 27 RGE 03 BEG INT SLN SEC23 WITH W MGN ADMIRAL WAY TH N41 "48 COE ALGSD W MGN TO SWLY MGN DAYTON ST TH LEGAL DESCRIPTION NWLY ALG SWLY MGN DAYON ST & EXT THOF TO INNER HARBOR LN TH S44'59 30W ALG SD INNER HARBOR LN TO S LN SEC TH WLY ALG SLN SECTO POB EXC BLDGS ONLY ON 232702-4-014-0104 TAX PARCEL NUMBER 27032300401400 PROJECT CONTACTS CONTACT POSITION EMAIL TELEPHONE RYAN MCLAUGHLIN PROJECT MANAGER RYANM@ENVIROMECH.COM 206-391-9709 JAE YOO MECH DESIGNER JAEY@ENVIROMECH.COM 206-762-1960 In 0 In I N � � 0 O Ld Z Z 1' �: 0 m Q Ld 0 D� = D 0 U w w N N r TU) O U Q o CO co rn Ujco ~ rl- co I` U o0 CV CD N ATM Ney Q U_ LL Z Q U) _ � 00 C)�M LU G Lo � Q LU F- 0 o c .0 W J 0- co W° 2 U z m o W U C:) 00 O-3 W C) < In �-U) Z o00 < i W Z 0N� 0 N co w RECEIVE Nov 21 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCHEDULES AND PROJECT INFORMATION SHEET NO. M 1 El 300 CFM--,I co 14%12" UP F -1 TO RTU 4 j L JI JI tlL L XII II IL JI_ CFM-J/' pit\J-2010 �+ tt tt I L E I _— RTU-fi 300 CFM -- „ I 0 8"0 ' IL 71, I;tl 14\ { IXl I 12"0 14"0 E I 10"� , L-J "0 8"� �,I,, � F"14, 8"0A I I 21 =14" — — — — — — — — — — — — — — — — — — I — — — — — — J F 200 CFM-, 13 12 10 8 14"x12" UP 200 CFM--, TO RTU-1 - `t XI L Vr TO RTU-6 PARTIAL 2ND FLOOR HVAC PLAN - DEMO SCALE: 1 /8" = 1'-O" -200 CFM I H'"o{ t�IIj II I I I II II IL JI IL JI 11 BALCONY -�!-�-I momilmmom lmmmmmm 1-200 CFM I I I 12%12" UP I TO RTU-2 I 8"200 CFM I „0 J r------J I 200 CFM I I I I I D� W m OPEN PORTFOLIO OFFICE14"x12" UP MANAGEMENT PARTIAL 2ND FLOOR HVAC PLAN - NEW SCALE: 1 /8" = 1'-O" ME :E UP -2 ATE ;E M NG ARE, In 0 L� N N >- :2 0 O Z Z Y 3 U M a w o _ � � U w w N N 1E U) LlU O Q o CO `cy)° rn ~ z r- r- O U �O N O N Q U_ LL z Q U Ucy)� LEI Lo Q LU cn o c .(3) L L' J cy) �0 W° 2 U z m DCN O �Lu V U >� > O 00 O LLJ U Q �_ / U) z LLJ> Q � 0 Lu z<0 O N N o co W RECEIVE Nov 21 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PARTIAL 2ND FLOOR HVAC PLANS SHEET NO. M-2.1 0 I N N � � 0 � Z Z Y � U m Q W O � o U Ln Ln IL O U) B � 0 C O LlU Q0 � Q rn rn w (0 C\4 C\j (.0 ' Z r� � O o 0 U N N O Q�LL x1 — Cu-1 - Z Q co 2CO �00 O ��� O O wLoQ we -r - - �o� CO CW Zone Corner Flag ........ D O O WU Setbacks: Required Actual Front -------------- Sides ..--.--..... O z D o J >- N w Rear ...: �Qo (D 3 o Other w Q 30 28 4.4 _ oo >- — Height Z co 0 0 g E � z<0 W o IN N 0Mo F w APPROVED BY PLANNING 1 c� — 13 12 10 8 2 1 Dec 08 2022 RECEIVE Nov 21 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PARTIAL ROOF HVAC PLAN - NEW SHEET NO. PARTIAL ROOF HVAC PLAN - NEW SCALE: 1/8" - 1,-0.. M-2.2 W W N N