Loading...
REVIEWED BLD BLD2021-0235+heating Energy_Calculations+3.18.2021_11.55.58_AM+2099632REVIEWED Simpl Heating System ashington State This he ing system sizing calcul i based on the Prescriptive and S. i�o+tayLLul�F�atirlgJq�S�nly.OM,9f Please mpletlle the green drop -downs and boxes that are applic, values II be calculated for you. If you do not see the selection yc BLD2021-0235 RECEIVED Mar 30 2021 uirements of the 2018 Washington State Energy Code (WSEC) and A00Pd6lmmmMl r sizing cooling systems should be used to determine cooling IoadSIDEVELOPMENT SER DEPARTMENT to your project. As you make selections in the drop -downs for each section, some :ed in the drop -down options, please contact the WSU Energy Program at Project Information Contact Information 1OHNTRANG 10HNTRANG 23129 74th AVE West EDMONDS, WA 98026 206-227-1031 iohntrana2m(alvahoo.com 1W Heating System Type: O All Other Systems 0 Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" Design Temperature Instructions Design Temperature Difference (AT) Edmonds AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 1,883 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.5 17,889 Glazing and Doors U-Factor X Area = UA Instructions u-oso '. 0.300 a 884 265.20 Skylights U-Factor X Area = UA Instructions 0.50 --- Insulation Attic U-Factor X Area = UA Instructions R-49 0.026 2,464 64.06 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions Select R-value � No selection --- Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions 0.056 3,868 216.61 R-21 Intermediate � Floors U-Factor X Area UA Instructions R-11 0.029 1,883 54.61 Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions Select R-value � No selection --- Slab Below Grade (see Figure v F-Factor X Length UA Instructions Select conditioning � No selection --- Slab on Grade (see Figure 1) F-Factor X Length UA Instructions Select R-Value � No selection --- Location of Ducts Instructions Duct Leakage Coefficient Conditioned Space 1.00 Sum of UA 600.48 Figure 1. Above Grade 46 Envelope Heat Load 27,622 Btu / Hour Sum of UA x AT Air Leakage Heat Load 8,887 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 36,509 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 36,509 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 45,636 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Buildinq and duct heat loss x 1.25 for heat pump (07101113)