Loading...
BLD2023-0340_Site_Plan_3.17.2023_2.13.23_PM_3428488Equipment Summary Modules: (29) REC 405W AA Inverter(s): (1) SolarEdge 1000OH-US Racking: Ironridge XR100 Table of Contents: Cover Page Al Site Overview A2 Roof Layout E1 Single Line E2 Electrical Calculations G1 Roof As Built G2 Electrician As -Built G3 Micro/optimizer map G4 Placards G5 Equipment BOM General Notes: Additional Electrical Work: - Install Clipper Creek EV Charger .._:_ jr�.16_ _01f !i Net Meter x Site 0 N A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U 0O o O L.0 = N � O O O ZM UO) Q � U C C C) ,-. "D p Cy) vi ,Q J NO E L IN U a ,w � w REVISIONS Rev. #: IDate: Designed by: Wes K. Project Manager: Will MacArthur (206)307-1741 Current Date:Mar 16, 2023 Cover Page o F-1 MSP OO O EV Charger N O Net Meter, Inverter, AC Disconnect, Customer -Owned Production Meter Attachment Detail Side View (Portrait) FLASHING AS REQUIRED TO SEAL ROOF MINIMUM (1) 5/16 X 4.75 LAC BOLT EMBEDDED 2" MINIMUM CENTER ON ROOF FRAMINC PV MODULE, BY OTHERS IRONRIDGE RAIL (E) COMPOSITION SHINGLE ROOF IRONRIDGE FLASHFOOT2 (E) ROOF FRAMING Modules not to exceed height of existing ridge -------i-------- '611 (sample) Attachment point layout for array. 72" OC Max. &M-1IPi. A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. Q p L O N _� OL() OCO O O M U O) Q � U C C C) �-. O p 0) vi .O� J 06 0� E L I� U _0 a w w REVISIONS Rev. #: I Date: Designed by: Wes K. Project Manager: Will MacArthur (206) 307-1741 Current Date:Mar 16, 2023 Al Site Overview Required Setbacks from Ridge: 18., Maximum Mount Spacing: 72^ `„I'' Roof Type: Comp Roof Slope: A&RSO BAR Array Tilt : Flush Array Azimuth(s): 2700 3211 Martin Luther King Jr Way S. Roof Area: 1789 ft2 Seattle, WA 98144 (206)707-9937 Array Area 578 ft2 Array to Roof Coverage 32% * * *Roof Attachments/ Fastners: see pg. G5 Equip. BOM* rV THIS DRAWING CONSTITUTES THE \ CONFIDENTIAL INFORMATION OF A&R SOLAR 'r1 AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN Q NOR ANY RIGHT TO REPRODUCE THIS DRAWING ANY PART HEREIN WITHOUT "A" THEWRITTEN N CONSENT OF A&R SOLAR. npn U - O� _ OLNn �000 O U M O ,—I N fu Q U c O a C) 0 p vi Module and Rail Selection Guide ,�_ Om o V - M c O U T ❑ a w w 00 I rl � 00 M NRev. #: Date: Designed by: Wes K. Project Manager: Will MacArthur (206)307-1741 Net Meter Current Date:Mar 16, 2023 A2 Roof Layout REC405AA Pure 40 x 71.7 Clamp Zone "A" 7.9-11.8" Clamp Zone "B" 14.8-19.9" Mods per Row Rail typel+ rail type2 (7)Portrait, (2)rows (2)14', (2)14' (5)Portrait, (2)rows (2)14', (2)split 14' (5)Landscape, (1)row (2)17', (2)14' I I I I I I I String 1 z 10 modules + o V_ _ _ _ _ _ String 2 � o 10 modules + String 3 AA AB 9 modules + 0 Equipment Schedule I Line C O Load �-------� I Located less than 10' I from net meter and I I I �t--------- 5 Customer Owned Production Meter 0 Ref. Category Equipment QTY 1 Modules REC405AA Pure 29 2 Optimizers S440 SolarEdge Optimizer 29 3 Jbox Soladeck 2 4 Inverters Solar Edge SE10000H 1 5 MeterBase MeterBase-125A 4 Jaw 1 Meter Landis Gyr EA110000-OP29 240V 1 6 Disconnect 60A 240V 2 Pole I Heavy Duty, Fuse, Lockable 1 DisconnectFuse FLNR - 60 A Fuses for Disconnect (qty 1 /pole) 2 Monitoring SolarEdge PV Inverter Monitoring 1 ElectricalWork Clipper Creek EV Charger Install (wired to 50A breaker) 1 less than 10' from tap a Supply Side Connection 705.11 (Existing) Main Service Panel (1ph 240V Service) Main Breaker: 200A Bus Rating: 200A I I I L---.4 #6 GEC 1 ■=A&RScope `,'I' _ I = Existing or A&RSOLAR Others Scope 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT O CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN M NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. Service entrance conductors Neutral Bar 4/0 XHHW-2 w/ bonding jumper (L1 & L2) 2/0 XHHW-2 (N) nverter Specs Watts � Output AC Voltage # of Inverters OCPD ll SolarEdge SE10000H 10000 42 240 1 60 ****N/A**** 0 0 0 0 0 ****N/A**** 0 0 0 0 0 Module Specs Watts w Imp Vmp Voc Isc REC405AA Pure 405 9.56 42.4 48.9 10.14 Temp. Adjusted 0 0 38.7 52.7 0 General Notes: 0 Conductor Schedule Utility: SnoPUD 1. EGC Where exposed to physical damage will be #6AWG Bare CU Summary Distance (ft) Current Operating Voltage Volt. Drop @125% Voltage Drop (total) 2. If installing conduit on the roof, maintain greater than 7/8" above the surface 3. NEC 690.12: Rapid Shutdown initiated by loss of Grid or AC Disconnect 4. For supply side taps, a #6 GEC (min.) will be run separately from the disconnect and connected to the grounding electrode with an irreversible crimp A (2)#10 CU, (1)#6 EGC, PV Wire 600V, AIR 50 18.75A 400V 0.31% 0.97% B (6)#10 CU, (1)#10 EGC, THWN-2, 0.75"EMT(min) 50 18.75A 400V 0.31% C (2)#6 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) 10 52.5A 240V 0.17% D (2)#6 CU, (1)#6 N, THWN-2, 1"PVC(min) 10 52.5A 240V 0.17% U O j O O O In N CO O O � M U M ,-I � c IN fu a U O n 0 p vi �_� JOM ,-. O L n U a A ww REVISIONS Rev. #: Date: Designed by: Wes K. Project Manager: Will MacArthur (206) 307-1741 Current Date:Mar 16. 2023 E1 Single Line PV Electrical Calculations Inverter ppt Input Amperage (Imp) Voltage (Vmp) Itag e(DC) Amps (DC) &A'AI P A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144(206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF AIR SOLAR. U �< _� O o ,� U �+ �_ � �O� L I� o �O oNn �000 Z M UM Q) � Q c o a L- M p vi .-� -J C: dSN� E U a ,� ,-� w w REVISIONS Rev. #: Date: Total Voltage Drop: 0.97% Designed by: Wes K. Project Manager: Will MacArthur (206) 307-1741 Current Date:Mar 16, 2023 E2 Electrical Calculations Inverter Specs M Watts � Output AC Voltage # of Inverters OCPD Total AC Comb. EGC AC ll out. A OCPD Solar Edge SE10000H 10000 42.00 240 1 60 42.0 60 #10 Ampe ****N/A**** 0 0.00 0 0 0 ****N/A**** 0 0.00 0 0 0 Module Specs Watts LW-1 Imp Vmp Voc Isc Temp. Coef V(oc) EGC DC Volt REC405AA Pure 405 9.56 42.4 48.9 10.14 Max Array Specs (Adjusted for Temperature) Solar Edge SE10000H ****N/A**** ****N/A**** 1 2 3 1 2 3 1 2 3 10.13 9.11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 400.0 400.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 480.0 480.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 15.00 15.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Max Array Power(STC): 11.745 kW DC Max Continuous AC Power: 10kW AC Interconnection Calcs Main Breaker 200 Bus Bar 200 Max PV OCD AI lowed 40 PV OCPD Device Used 60 Tap or Breaker? Tap Site Conditions ASHRAE Site: Seattle Low Temp (°F) 19 High 2%Temp (°F) 84 High 0.4% Temp (°F) 91 Ref. Conductor Description Distance AL CU Wire Gauge �_ (4TY) Phase Neutral Neutral EGC AwG ( ) Wire Type Conduit Min. Conduit 90°C Rating Temp Correct. Fill Derate De rated 75°C Rating Current Operating_ Voltaire ft � Conductors Awe ��. Ty (Q ) T ype Ampacity @125% Voltage Drop A String to Jbox 50 Cu #10 2 N/A N/A #6 PV wire 600v AIR N/A 40 1 100% 40.00 35 18.8 400 0.31% B Jbox to Inverter 50 CU #10 6 N/A N/A #10 THWN-2 EMT 0.75" 40 1 80% 32.00 35 18.8 400 0.31% C I nverter to Disconnect 10 CU #6 2 #8 1 #10 THWN-2 EMT 0.75" 75 1 100% 75.00 65 52.5 240 0.17% D Disco. to Interconnect 10 CU #6 2 #6 1 #6 THWN-2 PVC 1" 75 1 100% 75.00 65 52.5 240 0.17% E F G H Typical Placards A) NEC 2020 690.13 & 691.15 B) NEC 2020 705.12 (13)(3)(2) C) Utility Requirement D) Utility Requirement (Utility -Owned) D) A&R Solar Requirement (Customer - Owned) E) A&R Solar Requirement * if combiner used F) NEC 2020 690.13 (B) I) NEC 2020 690.31 (D)(2) K) NEC 2020 690.13 (B) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SOLAR ELECTRIC PV PANELS SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY L) NEC 2020 690.56 (C) Located on or no more than 3' from the service disconnecting means to which the PV system is connected O) A&R Solar Requirement * if multiple inverters IAWARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM P) NEC 2020 705.12(C) & 690.59 ` • D• NOT INSTALL ADDITIONAL LOADS IN THIS PANEL R) AHJ Requirement * if combiner used S) NEC 2020 230.85(1) T) NEC 2020 230.85(3) Custom Placards PLACARD SPECS QT` G) NEC 690.54 MAX AC OUTPUT CURRENT: 42.0 A AC Letter Height: 1/8" Maintain border OPERATING AC VOLTAGE: 240 V AC Red / White MAX AC OUTPUT CURRENT: 42.0 A AC OPERATING AC VOLTAGE: 240 V AC Inverter Interconnection Point Letter Height: 1/8" Maintain 1/4" border 1 Solar Edge SE10000H Red / White Letter Height: 1/8" (1) for each Maintain 1/4" border 1 Disconnect or upstream Red / White loadcenters. &MIPi. A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. U 0O o O L = N L0 O O O � M U 0 ) a � U C C C) �-. � p Cy) vi .OLn J o'6N� E L rN U a LU w REVISIONS Rev. #: I Date: IDesioned bv: Wes K. I Project Manager: Will MacArthur (206)307-1741 Current Date:Mar 16, 2023 G4 Placards J) NEC 2020 690.56 (C)(2) A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. Q p O L 0 _ O O Ln� N 66 z M UM O,� a��fQ � U C C) �+ L- � p vi � J O O C .O� °6N� E U L I� a w w ,-� REVISIONS Rev. #: Date: Designed by: Wes K. Project Manager: Will MacArthur (206)307-1741 Current Date:Mar 16, 2023 G5 Equipment BOM Category Equipment QTY Notes Modules REC405AA Pure 29 Optimizers 5440 SolarEdge Optimizer 29 Jbox Soladeck 2 Inverters Solar Edge SE10000H 1 MeterBase MeterBase-125A 4 Jaw 1 Meter Landis Gyr EA110000-OP29 240V 1 Misc. 3.5" AWCAP (Meter Base Accessory) 1 Disconnect 60A 240V 2 Pole � Heavy Duty, Fuse, Lockable 1 DH222NRK DisconnectFuse FLNR - 60 A Fuses for Disconnect (qty 1 /pole) 2 Misc. Tap connectors IPCS4002 2 HCS-50 ElectricalWork Clipper Creek EV Charger (wired to 50A breaker) 1 IronRldge Racking BOM XR100 Black,l7' 2 XR100 Black,l4' 16 Kit, XR100 Bonded Splice BOSS 10 Universal Module Clamp, Black 68 Stopper Sleeve 30mm 20 Grounding Lug, Low Profile 5 Square -Bolt Bonding Attachment Hardware 51 1/4 x 3/4 Microinverter Bonding Hardware, T-Bolt 29 End Caps, 10 sets(package) XR100 1 IronRidge Flash Foot2, Black (Spacing: 72") 51 System Weights Racking Weight: 269.1(Ibs) Total Weight: 1574.1(Ibs) Weight/Attachment: 30.86(Ibs) Dead Load: 2.73(PSF)