Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2023-0340_Manufacturer_Specifications_and_Installation_Instructions_3.17.2023_2.13.19_PM_3428486
ELECTRICAL DATA Power Output - PMAx (W P) Watt Class Sorting-(W) Nominal Power Voltage -VMPP (V) u Nominal Power Current-IMpp(A) to Open Circuit Voltage-Voc(V) Short Circuit Current- Isc (A) Power Density (W/mz) Panel Efficiency (%) Product Code': RECxxxAA Pure 390 395 400 405 0/+5 0/+5 0/+5 0/+5 41.5 41.8 42.1 42.4 9.40 9.45 48.6 48.7 10.22 10.25 211 214 21.1 21.4 9.51 9.56 48.8 48.9 10.28 10.30 216 219 21.6 21.9 410 0/.5 42.7 9.61 49.0 10.35 222 22.2 Power Output - PMAx(WP) 297 301 305 309 312 Nominal Power Voltage-VMPP(V) 39.1 39.4 39.7 40.0 40.2 O No minaIPowerCurrent- IMpp(A) 7.59 7.63 7.68 7- 7.72 7.76 Z Open Circuit Voltage - Voc(V) 45.8 45.9 46.0 46.1 46.2 Short Circuit Current - Isc(A) 8.20 8.24 8.28 8.32 8.36 Values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m2, temperature 25°C), based on a production spread with a tolerance of PMAx, Voc& I5c 13 %within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m2, temperature 20°C, windspeed 1 m/s).* Where xxx indicates the nominal power class (PMAx) at STC above. MAXIMUM RATINGS WARRANTY Operational temperature: -40...+85°C Standard REC ProTrust Maximum system voltage: 1000V Installed by an REC No Yes Yes Certified Solar Professional Maximum test load (front): +7000 Pa (713 kg/m2)' System Size All ,25 kW 25-500 kW Maximum test load (rear): -4000Pa(407kg/m2)* Product Warranty (yrs) 20 25 25 Max series fuse rating: 25A Power Warranty (yrs) 25 25 25 Max reverse current: 25 A Labor Warranty (yrs) 0 25 10 See installation manual for mounting instructions. Power inYear 1 98% 98% 98% Design load =Test load/1.5(safetyfactor) Annual Degradation 0.25% 0.25% 0.25% Power in Year 25 92% 92% 92% See warranty documents fordetails. Conditions apply Available from: CERTIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 IEC62804 PID IEC61701 Salt Mist IEC 62716 Ammonia Resistance IS011925-2 Ignitability (Class E) IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) IEC 62321 Lead-freeacc. to ROHS EU 863/2015 ISO 14001, ISO 9001, IEC 45001, IEC 62941 CIUS C E [Ed�%J take ke wnnrey , 1take-e-way WEEE-compliant I-, tek Lead -Free recydmg"heme TEMPERATURE RATINGS* Nominal Module Operating Temperature: 44°C (±2°C) Temperature coefficient of PMAx: -0.26 %/°C Temperature coefficient of Voc: -0.24 %/°C Temperature coefficient of Isc: 0.04 %/°C *The temperature coefficients stated are linearvalues DELIVERY INFORMATION Panels perpallet: 33 Panels per 40ftGP/high cube container: 792 (24 pallets) Panels per13.6 m truck: 924 (28 pallets) Panels per 53fttruck: 891 (27 pallets) LOW LIGHT BEHAVIOUR Typical low irradiance performance of module at STC: 0 T w Irradiance (W/m2) Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar's Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia -Pacific. Power Optimizer For Residential Installations S440, S500 Enabling PV power optimization at the module level / Specifically designed to work with SolarEdge residential inverters / Detects abnormal PV connector behavior, preventing potential safety issues* / Module -level voltage shutdown for installer and firefighter safety / Superior efficiency (99.5%) * Functionality subject to inverter model and firmware version 0 N m / Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading / Faster installations with simplified cable management and easy assembly using a single bolt / Flexible system design for maximum space utilization / Compatible with bifacial PV modules solaredge.com solar =se Power Optimizer For Residential Installations S440, S500 Rated Input DC Power(') 440 500 W Absolute Maximum Input Voltage (Voc) 60 Vdc MPPT Operating Range 8-60 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part 15 Class 3, IEC61000-6-2, IEC61000-6-3, CISPRI1, EN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant ROHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 155 x 30 mm Weight (including cables) 655 / 1.5 gr / lb Input Connector MC4(1) Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 m Operating Temperature Range(') -40 to +85 C Protection Rating IP68 / NEMA6P Relative Humidity 0 -100 % (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed 12) For other connector types please contact SolarEdge (3) For ambient temperature above +70°C / +158°F power de -rating is applied. Refer to Power Optimizers Temperature De -Rating Technical Note for more details Minimum String Length 5440, 5500 1 8 1 16 1 18 Maximum String Length (Power Optimizers) 25 50 Maximum Nominal Power per Stringi^l 5700 112501s1 12750ib1 W Parallel Strings of Different Lenoths or Orientations Yes (4) If the inverters rated AC power s maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power Refer to: https://www.solaredge.com/sites/default/files/se-power-optimizer-single-string-design-application-note.pdf (5) For the 230/400V grid: it is allowed to install up to 13,500W per string when the maximum power difference between each string is 2,000W (6) For the 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W (7) It is not allowed to mix S-series and P-series Power Optimizers in new installations SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. E Ron i■� c All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2021 DS-000091-1.2-ENG. Subject to change without notice. Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / SE760OH-US / SE10000H-US / SE1140OH-US r® solarW- Y lDwave 1 _ .. _•► r O solar - .. - ., ��iL1.No�e . oK O O a 0 O Optimized installation with HD -Wave technology / Specifically designed to work with / Extremely small power optimizers / Record -breaking efficiency / Built-in module -level monitoring / Fixed voltage inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) / UL1741 SA certified, for CPUC Rule 21 grid compliance solaredge.com solar=@@ Single Phase Inverter Wit HID -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211 - 240 - 264) AC Output Voltage Min.-Nom.-Max. ✓ ✓ - - ✓ Vac (183 - 208 - 229) AC Frequency (Nominal) 59.3 - 60 - 60.Sn1 Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 - 24 - - 48.5 A Current @208V GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Yes Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240VI1j 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(I) - 9 - 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600kn Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(') Rapid Shutdown - NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG 3/4' minimum / 14-6 AWG 3/4" minimum /14-4 AWG Range DC Input Conduit Size / # of Strings / AWG Range 3/4" minimum / 1-2 strings / 14-6 AWG 3/4" minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / (HxWxD) mm Weight with Safety Switch 22110 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -25 to +6003 (-40`F / -40'C option)(') "F / °C Protection Rating NEMA 4X (Inverter with Safety Switch) 0) For other regional settings please contact SolarEdge support m A higher current source may be used; the inverter will limit its input current to the values stated (1) Revenue grade inverter P/N: SExxxxH-US000NNC2 (4) For power de -rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf 15) -40 version P/N: SExxxxH-US000NNU4 O SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/201MOVENG NAM. Subject to change without notice. RoHS I RON RI DGE Class A Fire Rating Background All roofing products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. IronRidge Certification IronRidge was the first company to receive a Class A Fire Rating —the highest possible rating —from Intertek Group plc., a Nationally Recognized Testing Laboratory. IronRidge Flush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 & UL 2703 test standards. The testing evaluated the system's ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Flush hMMount LJ_J_J Tilt Mount Any Slope Test Setup ulaihiniType Mounting System Mounting is tested as part of a system that includes type -tested modules and fire -rated roof covering Roof Covering Roof covering products are given a Fire Class Rating of A, B or C based on their tested fire resistance. Burnl A burni Flame Spread of Flame Test Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph. The flame cannot spread 6 feet or more in 10 minutes. Type 1, 2, & 3 <_ 6 Degrees I Type 1, 2, & 3 Class A Class A 'Class A rated PV systems can be installed on Class A, B, and C roofs. Frequently Asked Questions What is a "module type"? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters and 2 fire performance parameters. The purpose of this classification is to certify mounting systems without needing to test it with every module. What roofing materials are covered? All fire rated roofing materials are covered within this certification including composition shingle, clay and cement tile, metal, and membrane roofs. What if I have a Class C roof, but the jurisdiction now requires Class A or B? Generally, older roofs will typically be "grandfathered in", and will not require re -roofing. However, if 50% or more of the roofing material is replaced for the solar installation the code requirement will be enforced. Where is the new fire rating requirement code listed? 2012 IBC: 1509.7.2 Fire classification. Rooftop mounted photovoltaic systems shall have the same fire classification as the roof assembly required by Section 1505. Where is a Class A Fire Rating required? The general requirement for roofing systems in the IBC refers to a Class C fire rating. Class A or B is required for areas such as Wildland Urban Interface areas (WUI) and for very high fire severity areas. Many of these areas are found throughout the western United States. California has the most Class A and B roof fire rating requirements, due to wild fire concerns. Are standard mid clamps covered? Mid clamps and end clamps are considered part of the PV "system", and are covered in the certification. More Resources 97 Installation Manuals Visit our website for manuals that include UL 2703 Listing and Fire Rating Classification. What attachments and flashings are deemed compatible with Class A? Attachments and their respective flashings are not constituents of the rating at this time. All code -compliant flashing methods are acceptable from a fire rating standpoint. What mounting height is acceptable? UL fire testing was performed with a gap of 5", which is considered worst case in the standard. Therefore, the rating is applicable to any module to roof gap. Am I required to install skirting to meet the fire code? No, IronRidge achieved a Class Afire rating without any additional racking components. What determines Fire Classification? Fire Classification refers to a fire -resistance rating system for roof covering materials based on their ability to withstand fire exposure. Class A - effective against severe fire exposure Class B - effective against moderate fire exposure Class C - effective against light fire exposure What if the roof covering is not Class A rated? The IronRidge Class A rating will not diminish the fire rating of the roof, whether Class A, B, or C. What tilts is the tilt mount system fire rated for? The tilt mount system is rated for 1 degrees and up and any roof to module gap, or mounting height. Engineering Certification Letters We offer complete engineering resources and pre -stamped certification letters. - UU LV 11 U....1UYt:.UU1 I. V If V11r41UYt:..U_. I RON RI DGE FlashFoot2 The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist -on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. Twist -On Cap FlashFoot2's unique Cap design encapsulates the lag bolt and locks into place with a simple twist. The Cap helps FlashFoot2 deliver superior structural strength, by aligning the rail and lag bolt in a concentric \ load path. r�� Single Socket Size A custom -design lag bolt allows you to install FlashFoot2 with the same 7/16" socket size used on other Flush Mount System components. / Three -Tier Water Seal FlashFoot2's seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS-100 Wind -Driven Rain Test. Water -Shedding Design An elevated platform diverts water away from the water seal. Installation Features B A Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. B Rounded Corners Makes it easier to handle and insert under the roof shingles. C Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. Benefits of Concentric Loading 1200 FlashFoot2 1000 fly > 800 Flash Foot v • Leading Competitor FlashFoot2 is the only product to align the ro 600 rail and lag bolt. This concentric loading 400 design results in a stronger attachment for the system. D 200 0 1 2 Rail -to -Lag Offset (in) Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. « Low -Cost Competitor Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. 3 // I RON RI DGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. K3 Compatible with Flat & Pitched Roofs Force -Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Corrosion -Resistant Materials XR Rails are IronRidge offers All XR Rails are made of marine -grade Oncompatible with a range of tilt leg aluminum alloy, then protected with an FlashFoot and options for flat anodized finish. Anodizing prevents surface other pitched roof M roof mounting and structural corrosion, while also providing attachments. applications. a more attractive appearance. XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. i XR10 XR10 is a sleek, low -profile mounting rail, perfectly matched to regions without snow. It achieves 6 foot spans, while also staying light and economical 6' spanning capability Moderate load capability Clear anodized finish Internal splices available Rail Selection ■ XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans. 8' spanning capability Heavy load capability Clear & black anodized finish Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. 12'spanning capability • Extreme load capability • Clear anodized finish • Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Load Rail Sp;,!iiiri!l11 W 0 2014 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 f&,� I RON RI DGE UFO Family of Components Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family —Flush Mount, Tilt Mount and Ground Mount —are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. Stopper Sleeve �ii�d�atee�st into Bonded Splice Grounding Lug f�wg amMEL Universal Fastening Object (UFO) The UFO securely bonds solar modules to XR Rails. It comes assembled and lubricated, and can fit a wide range of module heights. Bonded Attachments dffufi the __I& I RON RI DGE Flush Mount System Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre -stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance ® Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 20-Year Warranty ® Entire system and components meet �� Twice the protection offered by newest effective UL 2703 standard. competitors. System Diagram s�----------------u��---------- --- -- ------------------m----- - - - - -- --- -- --------------- ---mow-- -------- --- -- O UFO C Stopper Sleeve • Grounding Lug m Bonded Splice --L Ground Wire Q 6VWe* Eyg3hasd krrnFhdgen3o6+aasrrdbrainat3rt@rltienow&blo the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. UL Certification The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. 0 Go to IronRidgexom/UFO XR Rails UFO/Stopper d d ' XR1000 Only I �/ d d d N/A Bonded Splice Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters Enphase - M250-72, M250-60, M215-60, C250-72 & Power Darfon - MIG240, MIG300, G320, G640 Optimizers I SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire Rating =Class A Class A N/A Modules I Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. XR Rails O XR10 Rail i A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear & black anod. finish XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear & black anod. finish Clamps & Grounding O — UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear & black finish Attachments O FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill & black finish Resources Stopper Sleeves _L Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • 6 different sizes • Clear & black anod. finish Slotted L-Feet XR1000 Rail Bonded Splices A heavyweight mounting All rails use internal splices rail for commercial projects. for seamless connections. • 12' spanning capability • Extreme load capability • Clear anodized finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Drop -in design for rapid rail Bond and attach XR Rails attachment. to certified attachments. Secure rail connections Slot for vertical adjusting Clear & black anod. finish esign Assistant o from rough layout to fully E:Jngineered system. For free. o to IronRidge.com/design • T & Square Bolt options • Nut uses 7/16" socket • Assembled & lubricated • Self -drilling screws • Varying versions for rails • Forms secure bonding Microinverter Kits Mount Mls or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled NABCEP Certified Training 0%w Earn free continuing education credits, POP while learning more about our systems. Go to IronRidge.com/training © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20