REVIEWED FIR2022-0126+Fire_Sprinkler_Equipment_Specification_Sheets+11.15.2022_3.32.00_PM+3221674FIR2022-0126 Bulletin 014 Rev. N Reliable Model F1 FR56 Sprinkler Types RECEIVE Standard Spray Upright Standard Spray Pendent Nov 16 2022 Conventional Upright/Pendent CITY OF EDMONDS Vertical Sidewall DEVELOPMENT SERVICES DEPARTMENT Horizontal Sidewall Model F1 FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1 FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1 FR40 Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 Recessed Sprinkler Types Standard Spray Pendent Model F1 FR56LL & F1 FR42LL NSF Certified Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1 FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. FM Approvals (FM) 3. Loss Prevention Certification Board (LPCB) 4. VdS Schadenverhutung GmbH (VdS) 5. NSF Certified to NSF/ANSi Standard 61 Annex G (NSF) 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Reliable Automatic Sprinkler Co., Inc., 103 Model F1 FR Series Quick Response Glass Bulb Sprinklers Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 .y.i . Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright XLH Pendent E.] Pendent F1/F2 Product Description Reliable Model F1 FR series sprinklers are quick -response automatic sprin- klers with a glass bulb thermal element. Model F1 FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model F1 FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model F1 FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR Series sprinklers to apply water to a fire faster than standard -response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Fairview Park Drive, Elmsford, New York 10523 Cj c 0 z At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1 FR Series sprinklers provide a wide range of op- tions where quick -response, glass bulb sprinklers are used: • Pendent, recessed pendent, upright, horizontal side - wall, and vertical sidewall deflectors • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) • Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1 FR series sprinkler configurations. Model F1 FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1 FR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.Omm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1 FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1 FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model F1 FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1 FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1 FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1 FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers have a factory -installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1 FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1 FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick -response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inchesi mm Pendent 2.25 57 D RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Fi FR28 2.8 40 3/8 10 Upright 2.25 57 D RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 D RA1418 VdS Recessed Pendent 2.25 1 57 GFR2 RA14181 VdS Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 F1 FR42 4.2 60 7/16 10 Upright 2.25 57 D RA1423 cULus 1,2 Fi FR42LL 4.2 60 7/16 10 Pendent 2.25 57 D RA1410 cULus, NSF Recessed Pendent 2.25 57 GFR2 RA1410 cULus, NSF F1 FRXLH Pendent 2.25 1 57 D RA14131 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 (F1 FR42 4.2 60 7/16 10 with Pintle) Upright 2.25 57 D RA1423 cULus 1,2 Pendent 2.25 57 D RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 F1 FR56 5.6 80 112 15 Upright 2.25 57 D RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 "Conventional (Pendent or Upright)" 2.25 57 D RA1475 LPCB, VdS, EC 4 Pendent 2.25 57 D RA1415 cULus, NSF 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF F1 FR56LL 5.6 80 1/2 15 Concealed Pendent 2.25 57 RC1 RA14141 cULus, NSF 6 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 Fi FR56 5.6 80 1/2 15 Recessed Horizontal Sidewall 2.63 67 GFR2 RA1435 cULus, FM 8 F1 FR56 5.6 80 112 15 Vertical Sidewall (Pendent or Upright) 2.25 57 D RA1485 cULus, FM, LPCB 1,2,3,9 (') cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (1) Available with FM approved Polyester coating in black or white. (4) Available with LPCB and VdS approved Polyester coating. (1) VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (1) Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. (') cULus Listing of the F1 FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1 FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (1) cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (1) The F1 FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1 FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100PF (38PC) Max. Ambient Tem . Intermediate Temp. Classification 150?F (65PC) Max. Ambient Tem . High Temp. Classification 225r'F (107,"C) Max. Ambient Temp. 135PF (57PC) Temp. Rating 155PF (68PC) Temp. Rating 175PF (79PC) Temp. Rating 200PF (93PC) Temp. Rating 286PF (141PC) Temp. Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1 FR28 Recessed Pendent cULus Upright cULus Pendent VdS Fi FR40 Recessed Pendent VdS Pendent cULus F1FR42 Recessed Pendent cULus Upright cULus Pendent -- cULus, NSF -- FlFR42LL Recessed Pendent -- cULus, NSF -- Pendent cULus F1FRXLH Recessed Pendent cULus Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC F1FR56 Concealed Pendent cULus cULus,VdS,EC cULus Upright cULus, FM, LPCB, VdS, EC "Conventional Pendent or Upright)" LPCB, VdS, EC Pendent -- cULus, NSF - F1 FR56LL Recessed Pendent -- cULus, NSF - Concealed Pendent` -- cULus, NSF - Horizontal Sidewall cULus, FM Fi FR56 Recessed Horizontal Sidewall cULus, FM FFlFR56 Vertical Sidewall (Pen- dent or Upright) cULus, FM, LPCB * Model F1 FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model F1 Model F2 Model FP Deflector/ Model Orientation (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1 FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1 FR42 Recessed Pendent cULus cULus cULus RA1413 F1 FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 FlFR42XLH Recessed Pendent cULus cULus cULus RA1413 F1 FR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC RA1414 EC VdS, EC Fi FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1 FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS --�\\ F1 ESCUTCHEONS Uzz 3/4'[19mm] ADJUSTMENT E2 ESCUTCHEON 112'T 12.7mm] ADJUSTMENT 2 114" HOLE DIA. [57.2mmJ 1 15116" DIA [49.2mmJ l F S i i -1 II II K L J� 2 27132" DIA. [72.2mmJ 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1 '[25.4mm] AT MINIMUM RECESS = 318'T9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'[19mmi 7-7-77-7-77 AT MINIMUM RECESS = 3/8'[9.5mm F1 ESCUTCHEON i/s" AT MAXIMUM RECESS = 7/8'T22.2mm] [3.2mmJ AT MINIMUM RECESS = 1-5/8'[41.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8'[28.6mm] AT MINIMUM RECESS = 1-5/8'T41.3mm] Fig. 1 Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR40, F1 FR42LL, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon I I 1 " X 1/2"' REDUCER -----I----- 2 5/8" DIA. [66.7mm] HOLE IN CEILING , I 2 5/16" DIA. [58.7mm] CUP L J CEILING FACE OF FITTING TO FACE OF CEILING DIMENSION - AT MAXIMUM RECESS = 1-1/2 "T38mm] AT MINIMUM RECESS = 1 'T25.4mm] AT MAXIMUM RECESS = 9/16'T14.3mm] %2'T 12.7mm] AT MINIMUM RECESS = 1 'T25.4mm] ADJUSTMENT Al� 3 1/4" DIA. [82.6mm] Fig. 2 Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR40, F1 FR42LL, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1 'T25.4mmJ AT MINIMUM RECESS = 3/8'T9.5mmJ F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'[19mm] AT MINIMUM RECESS = 318'T9.5mm] 2 114" HOLE DIA. [57.2mm] 1 " X 112" REDUCER I ' iiiiii, 15116" (49.2mm] Ills 118" [3.2mm] F1 ESCUTCHEON AT MAXIMUM RECESS — 1 3 8" 34 9 — / [ . mmJ AT MINIMUM RECESS = 2-1/16'T52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8'T41.3mmJ AT MINIMUM RECESS = 2-1/16'T52.4mm] 2 27/32 " DIA. [72.2mm] TURN COLLAR UNTIL TIGHT AGAINST WRENCH BOSS. SPRINKLER `\`+ '\��, F1 ESCUTCHEON L 314'T 19mm] ADJUSTMENT ESCUTCHEON 1/2'T 12.7mmJ ADJUSTMENT 1 (1) 4"-12" [101.6mm-304.8mm] CEILING TO DEFLECTOR o1 RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" — 6" [101.6MM — 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon I" x 112" REDUCING TEE OR ELBOW r 2 518 " DIA. 2 5116 DIA — ;J HOLE IN CEILING L_ _J CUP ®� VU 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING I 712 " MAX. 15116 " COVER ADJUSTMENT r j COVER PLATE / ASSEMBLY 3 5116 " DIA. SPRINKLER CONCEALED. 1 /2" ADJUSTMENT 017FG01A Fig. 4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate Fn X TEE 112" REDUCING OR ELBOW _ 2 5116" CEILING 5116 " MAX. --I COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER - 2 518" DIA. HOLE IN CEILING CONCEALED, 5/16" ADJUSTMENT 1 112 " MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 017FG02A 514" Fig. 5 - Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.Omm) adjustment - Model CCP cover plate Maintenance The Model F1 FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (t) Standard Finishes Sprinkler Escutcheon Cover plateM Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plateM Electroless Nickel PTFE(7) Electroless Nickel PTFE Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2)(6) Black Paint Off White Off White(2)(6) Off White Satin Chrome Chrome Dull Chrome Dull (1) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi -gloss, unless specified otherwise. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (6) _PCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. (7 cULus listed Corrosion Resistant 7. Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Uprig ht][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewal 1] [Vertical Sidewall] 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135°F (570C)][155°F (680C)][175°F (790C)][200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model: [F1][F2][FP] 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.Omm) adjustment] 9. Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers] [1650F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled ® (800) 431-1588 Sales Offices Paper iable (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 12 /15 P/N 9999970300 Availability: Americas Bulletin 213 June 2022 Rel ® RASCOFLEX° Model RFB Sprinkler Connections cULus Listed, FM Approved Product Description RASCOFLEX° Sprinkler Connections are intended to connect a branch line to a sprinkler using a flexible stainless steel hose assembly. RASCOFLEX® Sprinkler Connections are suitable for use in suspended and hard ceiling applications such as T-Bar ceiling grids, wood, metal stud, or hat furring channel hard lid ceilings. Every package contains one (1) fully assembled stain- less steel flexible sprinkler system complete with hose, branch line connection, and sprinkler connection, as well as the pre -as- sembled bracket assembly to attach to the ceiling. RASCOFLEX° Sprinkler Connections are designed for use in hydraulically calculated wet, preaction, or dry sprinkler sys- tems per NFPA 13, 13R, 13D, and FM Global Loss Prevention Data Sheets. Technical Data Maximum Working Pressure FM: 200 psi (13.8 bar) UL: 175 psi (12.1 bar) Maximum Working Temperature 300°F (149°C) Connections Inlet/Branch Line 1" NPT Outlet/Reducer 1/2" or 3/4" NPT Minimum Allowable Bending Radius UL: 3" (76 mm) FM: 7" (178 mm) Maximum Number of Bends See Friction Loss Chart Maximum K-Factor 1/2" Outlet 5.6 (80 metric) 3/4" Outlet 14.0 (200 metric) Maintenance RASCOFLEX® Sprinkler Connections should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdic- tion. Patents RASCOFLEX® Sprinkler Connections may be covered by one or more of the following US Patent Nos. 10,173,088 and 10,328,296. Listings and Approvals FM Approved Class No. 1637 (FM) UL Listed and UL Certified for Canada to ANSI/UL 2443 (cULus) RASCOFLEX® Model RFB Sprinkler Connections Ordering Information Specify: Model Name • Model RFB Nominal Hose Length • 24" (610 mm) • 31 " (790 mm) • 40" (1015 mm) • 48" (1220 mm) • 60" 1525 mm) • 72" (1830 mm) Reducer Outlet: 1/2" NPT or 3/4" NPT Reducer Type Standard: • 7" (178 mm) straight Optional: • 11-3/4" (300 mm) straight • 7-1/4" (184 mm) elbow • 8-5/16" (211 mm) elbow Bracket Assembly Length • 24" (610 mm) standard • 48" (1220 mm) optional Accessories • See Table F www.reliablesprinkler.com Bracket Dimensions 28" [711] Standard or 52" [1320] Optional 7 f r � �n o u T L LID Lo LID Reducer Dimensions 00 T Lo - T u 7" (178mm) Straight Standard '—Nominal 1-11/16" (43mm) ceiling grid shown for reference only. Verify actual ceiling grid dimensions and ceiling tile reveal prior to ordering. 11-13/16" (300 mm) Straight I TMM T 7-1/4" (184mm) Elbow 8-5/16" (211 mm) Elbow Bulletin 213 June 2022 Page 2 of 8 www.reliablesprinkler.com Installation Dimensions _CD T i . ......... ..,'16" (43mm) ceiling grid shown for reference only. Verify actual ceiling grid dimensions and ceiling tile reveal prior to ordering. Minimum and Maximum Face of Fitting to Bottom of Ceiling Grid for Each Reducer (178 " Straight Standard 11-13/16" (300 mm) Straight 7-1/4" (184 mm) Elbow 8-5/16" (211 mm) Elbow Fig. 3 Dimension A Max. Face of Fitting 4° (102 mm) 4" (102 mm) 4° (102 mm) 4" (102 mm) Distance above Bottom of Ceiling Grid Fig. 3 Dimension B Max. Face of Fitting 1/8" (3mm) 4-7/8" (124 mm) 3/4" (19 mm) 5/16" (60mm) Distance from Bottom below below above below of Ceiling Grid Note: Based on 1-11/16" (43mm) tall ceiling grid. Fig. 3 Dimension C - Clearance Above Ceiling Required at Max. Sprinkler Recess Recessed Escutcheon or Concealed/Flush Sprinkler Reducer 7-1/4" (184 mm) Elbow 8-5/16" (211 mm) Elbow F1 recessed escutcheon NC 7-5/8" (194 mm) F2 or FV recessed escutcheon NC 7-3/8" (187 mm) FP recessed escutcheon 7" (179 mm) 8-1/8" (206 mm) CCP conical concealed cover plate 7" (179 mm) 8-1/8" (206 mm) G4 series concealed sprinklers 8-1/4" (210 mm) 9-1/4" (235 mm) G5 series concealed sprinklers 7-3/4" (197 mm) 8-7/8" (225 mm) RFC series concealed sprinklers 7-1/2" (191 mm) 8-5/8" (219 mm) XL commercial flush sprinkler with flat escutcheon 7-3/8 (189 mm) 8-1/2" (216 mm) XL commercial flush sprinkler with conical escutcheon 6-7/8 (176 mm) 8" (203 mm) Note: NC - Reducer not compatible with sprinkler adjustment range. Based on 1-11/16" (43mm) tall ceiling grid and flush ceiling tile. Bulletin 213 Reliable Page 3 of 8 June 2022 www.reliablesprinkler.com Materials Number Item Description Material Figure 4 KI]EMM, , 1 Flexible Hose/Bellow AISI Type 304 Stainless Steel 2 Isolation Ring Nylon 66 3 Gasket EPDM 4 Nut Zinc Plated Carbon Steel 5 Branch Line Nipple (1") Zinc Plated Carbon Steel 6 Reducer Zinc Plated Carbon Steel 7 Braid AISI Type 304 Stainless Steel 8 Welded Collar Fitting AISI Type 304 Stainless Steel - Bar Stock Zinc Plated SGCC Steel Brackets: Center and Side Zinc Plated SPCC Steel Flexible Hose Number of Bends One Bend Two Bends Figure 5 Three Bends Minimum bend radius 2x 2x Min 1 Min - - bend bend , radius radius OR OR Minimum bend radius 9MinimumL— %radiusbend radius%radius --- — imumM radius b be Minimum bend radius Note: Do NOT install the RASCOFLEXTM pulled straight or tight. Some flexibility in the form of an allowable bend or bends must be provided. Bulletin 213 Reliable Page 4 of 8 June 2022 www.reliablesprinkler.com cULus Friction Loss Data Nominal Length of Flexible Hose in (mm) Reducer Maximum Sprinkler K-Factor gpm/psi112 (Ipm/bar12) Maximum Number of 90' Bends at 3" (76mm) Bend Radius Equivalent Length of 1" (33.7mm) Sch. 40 Pipe (C=120), ft (m) NPT Threads Type 24 1/2 Straight 5.6(80) 2 10 (3) (610) 3/4 Straight 14.0 (200) 2 13 (4) 31 1/2 Straight 5.6(80) 3 14(4.3) (790) 3/4 Straight 14.0 (200) 3 16(4.9) 40 1/2 Straight 5.6 (80) 4 21 (6.4) (1015) 3/4 Straight 14.0 (200) 4 23 (7) 48 1/2 Straight 5.6(80) 4 24(7.3) (1220) 3/4 Straight 14.0 (200) 4 26(7.9) 60 1/2 Straight 5.6(80) 4 25(7.6) (1525) 3/4 Straight 14.0 (200) 4 30(9.1) 72 112 Straight 5.6(80) 5 36 (11) (1830) 3/4 Straight 14.0 (200) 5 33 (10.1) UL Notes: 1. Available data for use with 6.1" straight reducers. 2. RASCOFLEX° Sprinkler Connections have been tested and approved by Underwriter's Laboratories, Inc. for use in wet, preaction, and dry sprinkler systems per NFPA 13, 13D, 13R and UL2443. Bulletin 213 Reliable Page 5 of 8 June 2022 www.reliablesprinkler.com FM APPROVED FM Friction Loss Data Nominal Length of Flexible Hose in (mm) Reducer Maximum Sprinkler K-Factor gpm/psi,� (Ipm/bars") Maximum Number of 90' Bends at 7" 178mm) Bend Radius Equivalent Length of 1" (33.7mm) Sch. 40 Pipe e (C=120), ft (m) NPT Threads Type 1/2 Straight 5.6(80) 1 9.7 (2.9) 1/2 90' Elbow 5.6(80) 0 11.5 (3.5) 24 (610) 3/4 Straight 8.0(115) 1 9.9(3) 11.2 (160) 1 9.8 (2.9) 14.0 (200) 1 9.6 (2.9) 3/4 90' Elbow 8.0(115) 0 10.2 (3.1) 11.2 (160) 0 10 (3) 14.0 (200) 0 9.8 (2.9) 1/2 Straight 5.6(80) 2 12.4 (3.8) 1/2 900 Elbow 5.6(80) 2 15.8 (4.8) 31 (790) 3/4 Straight 8.0(115) 2 13.7 (4.1) 11.2 (160) 2 12.9 (3.9) 14.0 (200) 2 12.2 (3.7) 3/4 90' Elbow 8.0(115) 2 14.5 (4.4) 11.2 (160) 2 13.7 (4.1) 14.0 (200) 2 13(3.9) 1/2 Straight 5.6(80) 2 15.9 (4.8) 1/2 90' Elbow 5.6(80) 2 21.6 (6.6) 40 (1015) 3/4 Straight 8.0(115) 2 18.5 (5.6) 11.2 (160) 2 17.4 (5.3) 14.0 (200) 2 16.3 (4.9) 3/4 900 Elbow 8.0(115) 2 20 (6) 11.2 (160) 2 18.9 (5.7) 14.0 (200) 2 20 (6) 1/2 Straight 5.6(80) 3 19.0 (5.8) 1/2 900 Elbow 5.6(80) 3 25.9 (7.9) 48 (1220) 3/4 Straight 8.0(115) 3 22.7 (6.9) 11.2 (160) 3 21.5 (6.5) 14.0 (200) 3 20.5 (6.2) 3/4 900 Elbow 8.0(115) 3 24.8 (7.5) 11.2 (160) 3 23.6 (7.2) 14.0 (200) 3 22.6 (6.8) Bulletin 213 Reliable Page 6 of 8 June 2022 www.reliablesprinkler.com FM Friction Loss Data (cont.) Nominal Length of Flexible Hose in (mm) Reducer Maximum Sprinkler K-Factor ,I2 gpm/psi (Ipm/bar'/2) Maximum Number of 90' Bends at 7" (178mm) Bend Radius Equivalent Length of 1" (33.7mm) Sch. 40 Pipe (C=120) ft (m) ( ' NPT Threads Type yp 1/2 Straight 5.6(80) 4 23.7 (7.2) 1/2 900 Elbow 5.6(80) 4 33.1 (10) 60 (1525) 3/4 Straight 8.0(115) 4 29.1 (8.8) 11.2 (160) 4 28(8.5) 14.0 (200) 4 27(8.2) 3/4 90' Elbow 8.0(115) 4 32.2 (9.8) 11.2 (160) 4 31.1 (9.5) 14.0 (200) 4 30(9.1) 1/2 Straight 5.6 (80) 4 28.4 (8.6) 1/2 90' Elbow 5.6(80) 4 40.4 (12.3) 72 (1830) 3/4 Straight 8.0(115) 4 35.5 (10.8) 11.2 (160) 4 34.3 (10.4) 14.0 (200) 4 33.2 (10.1) 3/4 90' Elbow 8.0(115) 4 39.5 (12) 11.2 (160) 4 38.3 (11.6) 14.0 (200) 4 37.2 (11.3) FM Notes: 1. RASCOFLEX° Sprinkler Connections have been tested and approved by FM Approvals for use in wet, preaction, and dry sprinkler systems per FM data sheets 2-0, 2-5, and 2-8 per FM1637. 2. Differences in equivalent lengths are due to varying test methods, per FM 1637 standards. 3. Above data of friction loss for use with 6.1" straight reducers. Bulletin 213 Reliable Page 7 of 8 June 2022 www.reliablesprinkler.com Accessories List 7-1/4" (184 mm) 8-5/16" (211 mm) Elbow Reducer- Short Elbow Reducer- Long 1 /2": 71VI99003303 1 /2": 71VI99003302 3/4": 71VI99003305 3/4": 7M99003304 Replacement 7" (178 mm) 11-13/16" (300mm) Standard Straight Straight Reducer Reducer 1 /2": 71VI99003309 1 /2": 71VI99003308 3/4": 71VI99003328 3/4": 7M99003327 Hat Channel End Hat Channel End Metal Stud End Bracket- Short Bracket- Long Bracket -Short 3" (76mm) 3-3/4" (95mm) 1-1/2" (38mm) 7M99003310 7M99003311 7M99003312 Metal Stud End Bracket- Long 2-1/16" (53mm) T-Bar End Bracket- Short 2-5/8" (68mm) T-Bar End Bracket- Long 4-1/8" (105mm) 7M99003314 7M99003316 7M99003313 Beam Stud End Bracket Replacement Center Bracket 3" (76 mm) Bend Radius 7M99003317 7 M99003321 Indicator 4tiaWood - 7M99004179 1" Replacement NPT Inlet Adapter #2 Square Drive Bit 7M99004539 Replacement Gasket 0 7M99003322 7M99004319 48" (1220mm) - Bracket Assembly 7M99004840 z Bulletin 213 Reliabld Page 8 of 8 June 2022 www.reliablesprinkler.com