REVIEWED BLD2022-0502+Calculations+4.20.2022_12.36.47_PM+2814986MyBui tdi ngPermit.com o service of e0tyGov.net Construction Tip Sheet 05 REVIEWED BY Basic Deck CITY OFEDMONDS This tip sheet reflects code requirements of the 2018 International Residential Code (IRC) with Washington State Amendments. RECEIVED Typical Deck BLD2022-0502 Apr 22 2022 CITY �OFF EDMONDS NT This document provides building code information applicable to prescriptive residential°YrRTMENRVICEB deck design. You may need to hire a licensed architect or engineer to design a deck where any of the following conditions apply: • The deck serves other than a one- or two-family dwelling building • The deck design includes more than one level • The deck will support a hot tub, spa or other heavy object, including heavy deck covering (such as pavers) • The walking surface is more than 14 feet above grade • The deck ledger is attached to house overhangs, bay windows, bricks, stone, or concrete block • The deck is bearing on ground with a slope greater than 1 foot horizontal for every 1 foot vertical • The deck is self-supporting (not attached to an exterior wall) See Detaa t for ledger opeans. Joist Decking Votily span ratings of ptaposed docking. Joist Overhang 24' maximum. Joist Spacing F See span table and i tooting schedule. 04 min. up to 8'-W height 5x6 min. up to 10'•0* hii ght Non -corrosive metal poste beam connector Continuous solid blocking between joists Beam overhang 24" maximum January 14, 2022 See Page 6 for Ledger Attachment ax, Joist Span Son span IuWe 1- Beam Sao span table. Note: Guards are required when the deck walking surface is more Emoting than 30" above grade. See spun table and g footing schedule. MyBuildingPermit.com I Basic Deck eCityGov.net 2XI5 ,r. eC14CovA9iance �MyBuildingPermitxom a service of e0tyGov.net Construction Tip Sheet 05 Deck Construction Notes • Design loading for decks is based on 60 pounds per square feet (PSF) live load, 10 PSF dead load, and 1500 PSF soil -bearing capacity. • The illustrations and information in this tip Sheet may be used for decks whether or not they require a permit. See Tip Sheet 0 for when a permit is required. • All wood must be pressure -treated or naturally resistant to decay. Treat cuts, holes, and notches with end -cut solution. • Fasteners, hangers, nails, etc., must be stainless steel, hot -dipped galvanized, or as specifically required for the specified wood preservative used. The coating weights for zinc -coated fasteners to be in accordance with ASTM A 153. Provide documentation in the field showing the required fastener protection for the wood chosen for your deck. • You may modify any components of this Tip Sheet using accepted engineering practices. Any modifications must be reviewed prior to permit issuance. All attachments must be per manufacturer's installation instructions. • Visit MyBuildingPermit.com for additional Tip Sheets for stairs, handrails, and notching and boring. January 14, 2022 36" minimum high guard with intermediate rails Attachment of spaced so that a sphere pre -manufactured guardail Existingbuilding 4" in diameter cannot systems to deck components 9 shall be per manufacturer. pass through (See Tip Special blocking details may be Flashing Sheet 3). required by the reviewer. See detail 1 on page 6 for ledger Refer table page See page 8 for guardrail attachment options 3 for Joist Sizes post connection Decking and Spans Secure ballusters with (1) #8d wood screw top & bottom %4° spacing �— Refer to Table on page 3 for f recommended / Beam Size and Spans Note: for drainage Contractor to field verify adequacy of Knee braces are required if solid lumber for ledger distance from grade to top of connection. ost If an exit or egress from oexceeds 48". See detail n page 7 the existing building passes under the For post size and maximum proposed deck, or if there allowable height, see page 4 Is an existing patio under the proposed deck, 6'-8" minimum clearance must be maintained. Please Indicate openings In Manufactured post base cast in existing wall in elevation footing I view. Refer to Table on page 4 for Footing Size 3,000 psi concrete (no special Inspection required) Finished grade 1" Gear PrrO MinimumMal(2) #4 ea. way, 3" clear depth of . ti I I�I Ik to bottomof footing. foting 12"_ =L Footing to bear on 1..11 11- undisturbep eann. MyBuildingPermit.com I Basic Deck eCityGounet 2005 �: acttyGtrrl�6iarrta �MyBui ldi ngPermit.com a service of eCityGov.net Construction Tip Sheet 05 When using the tables below, interpolation is allowed, extrapolation is not allowed. Sizing of Structural Elements Maximum Deck Joist Span a,c Joist Joist Spacing b inches Joist Back Span Size 12 16 1 24 4 6 8 10 12 1 14 16 18 Allowable Joist Span Maximum Cantilever feet -inches Adjacent Joist Span feet 2x6 7-11 7-1 5-9 1-0 1-6 NP NP NP NP NP NP 2x8 10-5 9-5 7-8 1-0 1-6 2-0 2-1 NP NP NP NP 2x 10 13-3 11-6 9-5 1-0 1-6 2-0 2-6 2-8 NP NP NP 2x12 15-5 13-4 10-11 1-0 1-6 2-0 2-6 3-0 3-3 NP NP a. Includes Incising Factor. b. When using composite decking, maximum spacing of joists. c. Spans based on Doug Fir -Larch, factor. refer to manufacturer's installation instructions for Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service Minimum Beam Size Deck Joist Span feet 6 8 1 10 1 12 1 14 16 18 Beam Size c,d,e Maximum Beam Span a,b,d (feet -inches) 4x6 5-2 4-6 4-0 3-5 3-1 2-10 2-7 4x8 6-11 6-0 5-3 4-7 4-1 3-8 3-5 4x10 8-5 7-4 6-6 5-10 5-2 4-9 4-5 4x12 9-10 8-6 7-7 6-11 6-4 5-9 5-4 6x6 6-6 5-7 5-0 4-7 4-2 3-9 3-5 6x8 8-8 7-6 6-8 6-1 5-6 5-0 4-7 6x10 10-7 9-2 8-2 7-6 6-11 6-4 5-10 6x12 12-4 10-8 9-7 8-9 8-1 7-7 7-1 a. Spans based on Doug Fir -Larch, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. b. If 2x built up beams to make 4x or 6x beams, they shall be fastened with two rows of 10d (3-inch x 0.128-inch) nails minimum at 16 inches on center along each edge (507.5) c. Beam depth shall be equal to or greater than the depth of intersecting joist for a flush beam connection. d. Beam cantilevers are limited to the adjacent beam's span divided by 4. e. Includes incising factor. January 14, 2022 MyBuildingPermit.com I Basic Deck eCityGoa.net 2W5,'k 90tyGoWiance -40 MyBuildingPermitxom a service of eCityGovnet Construction Tip Sheet 05 Maximum Deck Post Height Tributary Area e Post 20 40 60 80 1 100 1201 140 160 Size c,d Maximum Deck Post Height a( et -inches) 4x4 10-0 10-0 8-7 7-0 5-8 4-1 N P N P 4x6 14-0 13-10 11-1 9-5 8-2 7-3 6-4 5-4 6x6 14-0 14-0 14-0 14-0 14-0 13-3 10-9 6-11 8x8 14-0 14-0 14-0 14-0 14-0 14-0 14-0 14-0 a. Measured from the underside of the beam to top of tooting. b. Based on Doug Fir, Hem Fir and Spruce -Pine -Fir, No. 2 grade, wet service factor. c. Notched deck posts shall be sized to accommodate beam size. d. Includes incising factor. e. Area, in square feet, of deck surface supported by post and footing. Footing Size a Tributary Area b Side of Square Footing (inches) Diameter of a Round Footing inches Thickness (inches) 5 7 8 6 20 12 14 6 40 18 20 6 60 21 24 8 80 25 28 9 100 28 31 11 120 30 34 12 140 33 37 13 160 35 40 15 a. Footing dimensions shall allow complete bearing of the post. b. Area, in square feet, of deck surface supported by post and footings. 12" min. frost depth In allowable soils Manufactured post connector -- Typical P.T. post Grade 12" t 1 p -1 I I 11-1 11-1 I I . I 11- I I-1 11, ` I-1 _ - 11=1 I I .': - °. I I 1-1 11-1 I I FL EME I 1-11 ,. a ;. Thickness per TableWidth °: ° a Qa. 4gravel Posts must be 1/2" diameterNote: in both pefthrough-bolts Min. 12" of centered on or in footing Table directions embedment Note: not screws January 14, 2022 MyBuiIdingPerm it.com I Basic Deck eCityGou net MC, sCI 36VMianea �MyBui ldi ngPermitxom a service of eCityGovnet Construction Tip Sheet 05 Deck Ledqer and Connections Deck Ledger Connection to Band Joist On -Center Spacing of Fasteners inches Joist Span c (feet) '/2-inch diameter lag screw with'/2-inch maximum sheathing b,c,e '/2-inch diameter bolt with'/2-inch maximum sheathing ° 1/2-inch diameter bolt screw with 1-inch maximum sheathing d 6 22 36 35 8 16 31 26 10 13 25 21 12 11 20 17 14 9 17 15 16 1 8 15 13 18 1 7 13 11 a. Ledgers shall be flashed in accordance with Section R703.4 to prevent water from contacting the house band joist. b. The tip of the lag screw shall fully extend beyond the inside face of the band joist. c. Sheathing shall be wood structural panel or solid sawn lumber. d. Sheathing shall be permitted to be wood structural panel, gypsum board, fiberboard, lumber, or foam sheathing. Up to 1/2-inch thickness of stacked washers shall be permitted to substitute for up to 1/2-inch of allowable sheathing thickness where combined with wood structural panel or lumber sheathing. e. For on -center spacing of specialized fasteners refer to the manufacturer's installation instructions. Placement of Lag Screws and Bolts in Ledgers and Band Joists Minimum End and Edge Distance and Spacing Between Rows Top Edge Bottom Edge Ends Row Spacing Ledger a 2 inches d 3/4 inch 2 inches b 1-5/8 inches b Band joist ` 3/4 inch 2 inches e 2 inches b 1-5/8 inches b a. Lag screws or bolts must be staggered from the top and bottom along the horizontal run. See figure below. b. Maximum 5 inches. c. For engineered rim joists, the manufacturer's recommendations govern. d. The minimum distance from the bottom row to the top edge of the ledger must be in accordance with figure below. e. 2 inches may be reduced to 3/4-inch when the band joist is directly supported by a mudsill, header, or by double top wall plates. January14, 2022 MyBuildingPermit.com I Basic Deck eCityGov.net M Z eGlKwAlianca .,/' MA" 'yBuildingPermit.com a service of e0tyGoy.net Construction Tip Sheet 05 EXTERIOR SHEATHING EXISTING STUD WALL Existing 2x BAND JOIST OR ENGINEERING RIM BOARD 2" 4fIN o DECK JOIST S MAX 2' MIN Lag screw or bolt 2" min. .�.. _ �.. 5" max. ;-�Z' min. Minimum edge distance for specialized screws. See manufacturer's technical bulletin. Ledger SCREWS OR BOLTS JOIST HANGER Stagger fasteners in 2 rows 5 112" min. for 2x8 6 1/2" min. for 2x10 7 1/2" min. for 2x12 " min. Distance can be reduced to 4 1/2" if lag screws are used or if bolt spacing is reduced to that of lag screws to attach 2x8 ledgers to 2x8 band joists Detail 1 — Ledger Attachment for Lateral Loads (Knee braces are required on posts greater than 4 feet in height.) Hold-down or tension device with 1500 # capacity Option # 1 January 14, 2022 Floor sheathing nailing at 6" o.c. (Max) to joist with hold-down. Sheathing Siding Flashing Decking Joists Joist Hangers Treated 2x ledger Floor foist 750# capacity holddown at 4 locations evenly dish along the deck and within each end. Install per manuf. Fully threaded 318" diameter tag screw predrilled with a minimum of 3 in embedment into solld framing. MyBuildingPerm it.com I Basic Deck Option # 2 2" min. or joists eCityGov.net M,E-e 4COvAgianm �MyBui ldi ngPermitxom a service of e0tyGoy.net Construction Tip Sheet 05 Connections and Fasteners (All fasteners, nails, bolts, screws, and connectors must be corrosion resistant.) Type of Connection: Notes: Manufactured Connectors Follow manufacturer's instructions Post to Footing Post base is required Post to Footing (High Winds) Consult with jurisdiction about additional uplift loads where wind exposure is greater than Risk Category B Post to Beam Connector is required Ledger to House Framing See information on Sheet 5 and Sheet 6 Joist to Beam or Girder 3 8d — Toe nailed Blocking or Bridging to Joist 2 1 Qd — Toe nailed at each end Wooden Deck Boards 2 8d threaded nails OR 2 No. 8 screws Composite Decking Follow manufacturer's instructions Post to Beam Connection with Knee Brace (Knee braces are required on posts greater than 4 feet in height.) Or 113 the height of the post. whichever is greater Corrosion resistant, min. metal column cap. -- Follow manufacturer's installation instructions. C N Alternate Knee Brace Detail: 2x4 knee brace face nailed ea. side of post and beam with 4-16d nails at each face and connection January14, 2022 IT, 4e MyBuildingPermit.com I Basic Deck Beam splices must occur over posts with 1-112" min_ bearing Girder beam 4 x 4 knee brace (1) 318" diameter thru-bolt or 112 " fag screws with washers, top & bottom (typical) Pressure treated wood post eCityGov.net 2MS ,'t aMVGadl;anca MyBui tdi ngPermit.com a service of eCityGov.net Construction Tip Sheet 05 Guards & Attachment Guards are required when the deck is more than 30 inches above grade.) through -bolts not allow the and washers passage of a 4" diameter sphere 2x2 Baluster, typical 2x6 or 5/4 board ail cap: attach to guard post with (3) #12 by 3" long screws or (3) 16d threaded nails with 0.148 nominal diameter 2x4 top and bottom; attach to guard post with (2) 8d threaded nails or (2) #8 wood screws >_ 2 1/2" long on inside face 4x4 guard post, typical Do Not Notch 2 x 8 nominal rim or outside joist, minimum Attach balusters at top and bottom with (1) #8 wood screw or (2) 8d post -frame threaded nails with 0.135 nominal diameter 16" � max A %$ O.D. galvanized bolt or threaded rod w/ nuts & washers 2/z 4x4 min. post @ 60" o.c. max., Typ J__ 7min min and 5" max 16" maxg-4 Min. 1800# tension device Section A O.D. galvanized bolt B or threaded rod w/ nuts & washers 2x8 min. blocking 2"min 2x8 min. deck 2"min / joists & rims 2)" min and 5' max 2"min Note: Use above details for guard connections or provide engineered Min. 1800# tension straps design that shows Guards can resist a single concentrated load of 200 III applied in any direction at any point along the top and Section B have attachment devices and supporting structure to transfer this load to appropriate structural elements of the building per IBC sec 1507.7.1.1 January 14, 2022 MyBuildingPermit.com I Basic Deck KityGounet 200K eClK4vAliaece