APPROVED ENG BLD PLN BLD2022-1295+Architectural_Plan+9.27.2022_4.10.06_PM+3132294SYMBOL LEGEND 1 A+ COLUMN GRID INDICATORS N 0 NORTH INDICATOR 1 A1.01 BUILDING ELEVATION INDICATOR 1 4 A1.01 2 INTERIOR ELEVATION INDICATOR 3 SECTION 1 -A1.01 BUILDING SECTION INDICATOR 1 A1.01 DETAIL INDICATOR +100.00' SPOT ELEVATION +100.00' LEVEL DATUM INSULATED STUD WALL 0 UNINSULATED STUD WALL CONCRETE WALL 0 NEW WALL DEMOLISHED WALL ROOM NAME ROOM IDENTIFIER 101 101 DOOR IDENTIFIER 1t WINDOW IDENTIFIER SG E "w- EGRESS INDICATOR SAFETY GLASS INDICATOR W1 WALLTYPE IDENTIFIER (:a REVISION INDICATOR CLOUD DS DOWNSPOUT SD SMOKE DETECTOR S G COMBINATION SMOKE & CARBON MONOXIDE DETECTOR EXHAUSTFAN SITE NOTES 1 . SITE INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO, TOPOGRAPHIC ELEVATIONS, DIMENSIONS AND LOCATIONS OF EXISTING UTILITIES, IS BASED ON CITY OF EDMONDS DATA, AND IS PROVIDED FOR INFORMATIONAL PURPOSES ONLY. THE ARCHITECTTAKES NO RESPONSIBILITY FOR ITS ACCURACY. 2. CONTRACTOR SHALLVERIFY LOCATION OF ALL EXISTING UTILITIES. CARE SHOULD BE TAKEN TO AVOID DAMAGE TO OR DISTURBANCE OF EXISTING UTILITIES. 3. NO SEDIMENT SHALL BE TRACKED ONTO THE STREET OR ONTO PAVED SURFACES. SEDIMENT SHALL BE REMOVED FROM TRUCKS AND EQUIPMENT PRIOR TO LEAVING THE SITE. IN THE EVENT OF FAILURE OF THE EROSION CONTROL SYSTEM RESULTING IN SEDIMENT BEING TRACKED ONTO PAVED SURFACES, THE CONTRACTOR SHALL IMMEDIATELY IMPLEMENT MEASURES TO CORRECT THE SITUATION, AND STREET SWEEPING SHALL BE EMPLOYED ON AN EMERGENCY BASIS. IF STREET SWEEPING VEHICLES ARE UTILIZED, THEY SHALL BE OF THE TYPE THAT ACTUALLY REMOVES THE SEDIMENT FROM THE PAVEMENT. 4. ALL EARTH SURFACES EXPOSED BY WORK PERFORMED SHALL BE LANDSCAPED WITH SUITABLE VEGETATION TO PREVENT EROSION FOR THE PERMANENT CONDITION. 5. ALLTEMPORARY CUTS MUST BE NO STEEPER THAN 1-1/2HTO IV IN FILLAND MEDIUM STIFF COLLUVIUM AND NO STEEPER THAN 1 H:1V IN UNDERLYING STIFFTO HARD GLACIAL DEPOSITS. 6. NO ENCROACHMENT IS ALLOWED ON ADJACENT PROPERTY, INCLUDING WORK FOR TEMPORARY EXCAVATIONS, LANDSCAPING, OR RETAINING WALL CONSTRUCTION. VICINITY MAP h 40 If st q T Q Main St M Dayton St C/) — d Dayton St a v � > Q > a � L L a Alder St APPROVED BY PLANNING Oct 05 2022 Maple St WALL AND PAVERS SHALL BE LOCATED ENTIRELY ON PRIVATE PROPERTY. ALL WORK SHALL COMMENCE FROM WITHIN PRIVATE PROPERTY. SHOULD ANY PORTION OF THE SIDEWALK NEED TO BE USED, A SEPARATE RIGHT-OF-WAY CONSTRUCTION PERMIT SHALL BE OBTAINED. ENGINEERING DIVISION APPROVED AS NOTED Jd] U/je,� 10/13/2022 VV City Of Edmonds Building Department ----------------------------------------------------- Work TRELLIS AND LADNSCAPING ------------------------------------------------------- ----------------------------------------------------- Address: 117 5TH AVE S =--------------------------------------------- -------------------------------------- Owner RED TWIG ---------------- ------------------- Approved Date -- -- -- -- -- -- 10/1-1/2022 Building Official: 5-ock C ale_ee c- Permit Number' BLD2022-1295 ------------------------------------------ Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. SITE N O GENERAL NOTES 1 . IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT ALL WORK COMPLY WITH THE 2018 INTERNATIONAL BUILDING CODE, 2018 WASHINGTON ENERGY CODE, AND OTHER APPLICABLE CODES, RULES, AND REGULATIONS OF JURISDICTIONS HAVING AUTHORITY. 2. PRIOR TO COMMENCEMENT OFANY PORTION OF THE WORK, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OFANY DISCREPANCIES NOTED AMONG OR BETWEEN THE CONTRACT DOCUMENTS, OWNER -PROVIDED INFORMATION, SITE CONDITIONS, MANUFACTURER RECOMMENDATIONS, OR CODES, REGULATIONS, OR RULES OFJURISDICTIONS HAVING AUTHORITY. 3. PRIOR TO COMMENCEMENT OFANY PORTION OFTHE WORK, THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE CONTRACT DOCUMENTS, OWNER - PROVIDED INFORMATION, AND SITE CONDITIONS, INCLUDING TAKING FIELD MEASUREMENTSAS NECESSARY. 4. THE CONTRACTOR SHALLSECUREAND PAY FORALL GOVERNMENTAL PERMITS, FEES, LICENSES, AND INSPECTIONS NECESSARY FOR PROPER EXECUTION AND COMPLETION OFTHE WORK, EXCEPT FOR THE GENERAL BUILDING PERMIT. 5. THE CONTRACT DOCUMENTSARE COMPLEMENTARY AND WHAT IS REQUIRED BY ONE SHALL BE BINDING AS IF REQUIRED BYALL. 6. REPETITIVE FEATURES NOT INDICATED IN THE DRAWINGS EVERYWHERETHAT THEY OCCUR SHALL BE PROVIDED AS IF DRAWN IN FULL. 7. ALL DIMENSIONSARE TO FACE OF FRAMING OR FACE OF CONCRETE, UNLESS OTHERWISE NOTED. CONTACTARCHITECT FOR CLARIFICATIONS. 8. DO NOT SCALE THE DRAWINGS. EXIST. CONC. PEDESTAI NEW 2X2 PAVERS OVER EXIST. ASPHALT PAT ALIGN LEVELW/ EXIST. CONC. PAT 453.50 MANORSTONE RET. WALL & C/ ALL CONSTRUCTION MATERIALS SHALL BE STORED ENTIRELY ON PRIVATE PROPERTY. USE OF THE RIGHT-OF-WAY FOR CONSTRUCTION EQUIPMENT OR MATERIALS WILL NOT BE ALLOWED. OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE Special inspections required: 1. For on site welding or if shop fabricated, provide shop certifications. 2. Epoxy anchors shall be installed and inspected by a certified inspector. Provide reports and documents to inspector. 5 Handrails in accordance with IBC 1010.11 are required. 1 SITE PLAN 1 /8" = 1'-0" ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED LEGAL DESCRIPTION CONTACTS w U Z P D2 z Z CITY OF EDMONDS BLOCK 120 D-00 - W 24.73 FT OF LOT 39 OWNER: � a g = a LESS N 40 FT AND LOT 40 LESS N 40 FT RED TWIG EDMONDS LLC W SITUATE IN THE COUNTY OFSNOHOMISH,STATE OF 1175THAVE S ``=w WASHINGTON. EDMONDS, WA98020 ARCHITECT: CODE SUMMARY CAPSULE CONTACT: MIKE La FON BUILDING CODE: 2018INT'LBUILDING CODE 2366 EASTLAKEAVEE#403 ENERGY CODE: 2018 WASHINGTON ENERGY CODE SEATTLE, WA 98102 w v a LAND USE CODE: ECC, TITLE 17 t: 206.395.9672 a' " a T ZONING: BD1 e: mike@capsule-space.net � � a � n N OVERLAYS: N/A a ENV. CRITICAL AREAS N/A ENGINEER: w HEIGHT LIMIT: 30' HARRIOTT VALENTINE ENGINEERS N STREET SETBACK: 0' CONTACT: TODD VALENTINE REAR YARD SETBACK: 0' 1932 FIRSTAVENUE#720 SIDEYARD SETBACKS: 0' SEATTLE,WA98101 PARKING REQUIREMENTS: 0 IN DOWNTOWN RETAIL CORE t:206.624.4760 e: tvalentine@harriottvalentine.com SNOHOMISH CO. PARCEL NUMBER CONTRACTOR: JAMES KASPER #00434212003900 t: 206.459.1507 e: kasperstairs@gmail.com PLANS MUST BE ON JOB SITE JST. PARKING F— ILL] w I— cn z O H a 0 ES w/ PLANTER TL RAILING EXIST. ✓ERS @ GRADE ATED BIKE RACK z0 RECEIVED Sep 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT cn Z 0 D' LU < M o a O_ LU cn o = z � U U M LU 0 0 Of tl ro E E CD c111 c"i o N N "' L U ui °' J Q m cl� ry LLJ 11 l� T U o 06CD 0 00 CO 0 a' M E 0-)LU0 0 .� � � Q Ln 0 � ru I..L w 00 z_z z � J Q W LU woz L= C)f w Cn a cD 2x4 CEDAR WD JOIST 4x8 CEDAR WD JOIST 2.5x2.5 HSS YARDARM EXIST. P.T. LEDGER @ BLDG 2.5xl /4" STEEL BRACE CONFIRM EXIST. DIMS 2.5x2.5 HSS FRAME I PROP. EAST ELEVATION 1 1 /4" = 1'-0" 13'-4" 13'-4" 13'-4" 2x4 CEDAR WD JOIST, TYP r r) PROPOSED TRELLIS SOUTH ELEVATION L 1 /4" = 1'_O" 4x8 CEDAR WD JOIST EXIST. P.T. LEDGER @ BLDG 2.5x2.5 HSS FRAME, TYP. EXIST. CONCRETE BASE o �v v� P 75 N J �a inma U �v o\ cn Z < 0 D' Lu a O_ Lu m o � U U L LI m U O 7 EXIST. PT LEDGER @ BLDG - Of E E o � N CD o NEW 2x4 CEDAR BEAMS, TYP. LuN cl') 0- NEW 4x8 CEDAR BEAM J Q NEW 2.5x2.5 HSS YARD ARM, TYP. R 13'-4" 13'-4" 13'-4" x x x x m cl� TRELLIS PLAN 3 ry W r 3"xl3" MANOR STONEWALL CAP 2'x2' CONC. PAVERS COLOR TBD BY OWNER 3/8" CLEAN BEDDING LAYER MANOR STONEWALL BLOCK 6"xl6" EA. ° 5/8" CLEAN CRUSHED ROCK COMPACTED VARIES w/ SLOPI NG SIDEWALK- e SAWCUT ALONG WEST EDGE EXIST. SIDEWALK ° a EXIST. ASPHALT SLOPES TO SIDEWALK II 6 12 MIN_ FOR WALL 6I I INFILTRATION TRENCH 18" 12" MIN 4 LANDSCAPING WALL & PAVERS DETAIL 3/4" = 1'-0" 42" MIN 3 1 /2" 5 RAILING DETAIL 3/4" = 1'-0" HSS TOP RAILw/ RUST PATINA & CLR SEALANT MATCH EXIST. RAILING PROFILE 4" WIRE MESH PANEL MATCH GAUGE & FINISH OF EXIST. RAILING 1-1 /2"xl -1 /2" HSS BTM RAIL w/ RUST PATINAAND CLEAR SEALANT 1-1 /2"xl -1 /2" HSS POSTS @ 48" O.C. MAX w/ RUST PATINAAND CLEAR SEALANT RECEIVED Sep 28 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT l� T CO o ,Ux W c"I 0 00 CO 0 a' m E �w 0 o .� � � Q Ln m ry (1) 1/4"0 SDS SCREW (TOE SCREW TO EX. LEDGER AND BEAM, TYP.) ATTACH EX. LEDGER TO EX. CMU WALL WITH (1) 3/8"0 x 5" LONG ANCHOR BOLT AT 3'-0"oc (EPDXY GROUT) JOISTS PER PLAN (TRIM TAILS PER ARCHITECTURAL) BEAM PER PLAN ATTACH WOOD BEAM TO HSS BEAM WITH (2) 1/4" x 5" LONG SDS SCREWS HSS BEAM PER PLAN STEEL BRACE PER ARCHITECTURAL ATTACH HSS POST TO EX. CMU WALL WITH (1) 3/8"0 x 5" LONG ANCHOR BOLT AT 2'-0"oc (EPDXY GROUT) HSS POST PER PLAN EXISTING CMU WALL PER PLAN M X 00 Q Provide special inspection reports to the City Inspector for welding and epoxy anchorage. NOTE: ALL LUMBER IS TO BE CEDAR SEE 5/S1.0 FOR HSS BEAM TO POST CONNECTION GENERAL STRUCTURAL NOTES (THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS) CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS & THE INTERNATIONAL BUILDING CODE (2018 EDITION) 2. DESIGN LOADING CRITERIA: ROOF SNOW LOAD (Pf) . . . . . . . . . . . . . . . . . . . . . . . 25 PSF 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CON— DITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CON— STRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST VERIFIED. CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL ADJACENT UNDERGROUND UTILITIES PRIOR TO COMMENCING EXCAVATION. THE CONTRACTOR SHALL BRING ALL CONFLICTS AND DISCREPANICES TO THE ATTENTION OF THE ARCHITECT AND STRUCTURAL ENGINEER. 5. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. EXISTING REINFORCING SHALL BE RETAINED UNDAMAGED WHERE NOTED ON THE PLANS. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. ALL NEW OPENINGS THROUGH EXISTING CONCRETE OR MASONRY WALLS, SLABS AND BEAMS SHALL BE ACCOMPLISHED BY SAW CUTTING WHEREVER POSSIBLE. 6. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CON— TRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CON — CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 8. SPECIAL INSPECTION OF THE FOLLOWING TYPES OF CONSTRUCTION SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 109 AND 1704 OF THE INTERNATIONAL BUILDING CODE AND THE PROJECT SPECIFICATIONS BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE ARCHITECT, AND RETAINED BY THE BUILDING OWNER. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING DEPARTMENT SHALL BE INFILL TUBE JOINT WITH PLATE TO MATCH HSS WALL EXPLODED JOINT VIEW �I I — HSS COLUMN PER PLAN II II BEVEL TYP. 3/16 FURNISHED WITH COPIES OF ALL INSPECTION AND TEST RESULTS. A. STRUCTURAL STEEL FABRICATION AND ERECTION (INCLUDING FIELD WELDING AND HIGH —STRENGTH FIELD BOLTING) B. EPDXY GROUTED INSTALLATIONS 9. SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION OF THESE ITEMS. A. STRUCTURAL STEEL ANCHORAGE 10. EPDXY —GROUTED ITEMS SPECIFIED ON THE DRAWINGS SHALL BE GROUTED WITH "SET—XP" HIGH STRENGTH EPDXY AS MANUFACTURED BY THE SIMPSON COMPANY AND INSTALLED IN STRICT ACCORDANCE WITH ICC ESR 2508. STEEL 11. STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL BE BASED ON THE LATEST EDITIONS OF THE RISC SPECIFICATIONS AND CODES: A. SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (RISC 360) B. CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES (RISC 303) C. SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. BOLTS IN SHEAR OR BEARING TYPE CONNECTIONS NEED ONLY BE TIGHTENED TO THE SNUG TIGHT CONDITION PER SECTION 8(C). 12. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING MINIMUM STANDARDS. PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36, FY = 36 KSI. WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, FY = 50 KSI. STEEL PIPE SHALL CONFORM TO ASTM A53, TYPE E OR S, GRADE B, FY = 35 KSI. SQUARE OR RECTANGULAR STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B, FY = 46 KSI. ANCHOR BOLTS AND CONNECTION BOLTS SHALL CONFORM TO ASTM A307. THREADED ROD AND STUDS SHALL CONFORM TO ASTM A36. 13. ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND AWS STANDARDS AND SHALL BE PERFORMED BY WABO CERTIFIED WELDERS USING E70XX ELECTRODES. ONLY PREQUALIFIED WELDS (AS DEFINED BY AWS) SHALL BE USED. WOOD 13. FRAMING LUMBER SHALL BE KILN DRIED OR MC-15, AND GRADED AND MARKED IN CON— FORMANCE WITH WCLIB STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17, LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (2X MEMBERS) CEDAR MINIMUM BASE VALUE, FB = 725 PSI BEAMS AND STRINGERS: CEDAR (INCL. 6X AND LARGER) MINIMUM BASE VALUE, FB = 750 PSI 14. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE — TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR MASONRY. ALL WOOD EXPOSED TO WEATHER WITHOUT THE ADEQUATE PROTECTION OF A ROOF OR EAVE SHALL BE AN APPROVED WOOD OF NATURAL RESISTANCE TO DECAY OR PRESSURE TREATED. SUCH MEMBERS INCLUDE HORIZONTAL MEMBERS SUCH AS GIRDERS, JOISTS, AND DECKING; OR VERTICAL MEMBERS SUCH AS POSTS, POLES, AND COLUMNS. 15. NAILS — NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SIZE LENGTH DIAMETER 6D 2" 0. 113" 8D 2-1/2" 0. 131" 10D 3" 0. 148" 12D 3-1/4" 0. 148" 16D 3-1/2" 0. 162" IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) FOR REVIEW AND APPROVAL. NAILS SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. NOTE: CONTRACTOR TO VERIFY WHETHER THE VOIDS IN THE EXISTING CMU WALL ARE GROUTED FULL. NOTIFY STRUCTURAL ENGINEER OF RECORD IF VOIDS ARE NOT NOT GROUTED PRIOR TO CONSTRUCTION. iiiii- --iiiii-- ®ii®iiiii=® iii'" ----- --iiiii -iiiii-- ----- --iii-- --iiii-- --iiii- ®iiiii 4 Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com Project Contact Liz Ihrig tel 206 756 0392 fax 206 447 6971 eihrig@harriottvalentine.com Project Architect Capsule 2366 Eastlake Ave E, #403 Seattle. WA 98102 Project Red Twig Bakery & Cafe 117 5th Ave S Edmonds, WA 98020 Issue Date Issue Description 09/19/2022 Permit Building Department Approval Drawing Title GENERAL NOTES/ U TRELLIS FRAMING PLAN06 / STRUCTURAL DETAILS m c� 1 TRELLIS FRAMING PLAN REC IVE-jpmber m 51.0 scale: 1/4' = 1'-0" Sep 2 3 2 CITY OF DMO 3 /4" = 1 ' — O" 4 3 /4" — 1 ' — O" DEVELOPMENT SE IC ■ DEPA TMEN 10 111�