Loading...
APPROVED FIR BLD FIR2023-0012+SITE & FLOOR PLAN+2.13.2023_12.55.28_PM+3366535SYMBOL LEGEND 1 A+ COLUMN GRID INDICATORS N ONORTH INDICATOR 1 A1.01 BUILDING ELEVATION INDICATOR 1 4 A1.01 2 INTERIOR ELEVATION INDICATOR 3 SECTION 1 -A1.01 BUILDING SECTION INDICATOR 1 A1.01 DETAIL INDICATOR +100.00' SPOT ELEVATION +100.00' LEVEL DATUM INSULATED STUD WALL 0 UNINSULATED STUD WALL CONCRETE WALL 0 NEW WALL DEMOLISHED WALL ROOM NAME ROOM IDENTIFIER 101 101 DOOR IDENTIFIER 1t WINDOW IDENTIFIER SG E "w— EGRESS INDICATOR SAFETY GLASS INDICATOR W1 WALLTYPE IDENTIFIER (:a REVISION INDICATOR CLOUD DS DOWNSPOUT SD SMOKE DETECTOR S G COMBINATION SMOKE & CARBON MONOXIDE DETECTOR EXHAUSTFAN SITE NOTES 1 . SITE INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO, TOPOGRAPHIC ELEVATIONS, DIMENSIONS AND LOCATIONS OF EXISTING UTILITIES, IS BASED ON CITY OF EDMONDS DATA, AND IS PROVIDED FOR INFORMATIONAL PURPOSES ONLY. THE ARCHITECTTAKES NO RESPONSIBILITY FOR ITS ACCURACY. 2. CONTRACTOR SHALLVERIFY LOCATION OF ALL EXISTING UTILITIES. CARE SHOULD BE TAKEN TO AVOID DAMAGE TO OR DISTURBANCE OF EXISTING UTILITIES. 3. NO SEDIMENT SHALL BE TRACKED ONTO THE STREET OR ONTO PAVED SURFACES. SEDIMENT SHALL BE REMOVED FROM TRUCKS AND EQUIPMENT PRIOR TO LEAVING THE SITE. IN THE EVENT OF FAILURE OF THE EROSION CONTROL SYSTEM RESULTING IN SEDIMENT BEING TRACKED ONTO PAVED SURFACES, THE CONTRACTOR SHALL IMMEDIATELY IMPLEMENT MEASURES TO CORRECT THE SITUATION, AND STREET SWEEPING SHALL BE EMPLOYED ON AN EMERGENCY BASIS. IF STREET SWEEPING VEHICLES ARE UTILIZED, THEY SHALL BE OF THE TYPE THAT ACTUALLY REMOVES THE SEDIMENT FROM THE PAVEMENT. 4. ALL EARTH SURFACES EXPOSED BY WORK PERFORMED SHALL BE LANDSCAPED WITH SUITABLE VEGETATION TO PREVENT EROSION FOR THE PERMANENT CONDITION. 5. ALLTEMPORARY CUTS MUST BE NO STEEPER THAN 1-1/2HTO IV IN FILLAND MEDIUM STIFF COLLUVIUM AND NO STEEPER THAN 1 H:1V IN UNDERLYING STIFFTO HARD GLACIAL DEPOSITS. 6. NO ENCROACHMENT IS ALLOWED ON ADJACENT PROPERTY, INCLUDING WORK FOR TEMPORARY EXCAVATIONS, LANDSCAPING, OR RETAINING WALL CONSTRUCTION. VICINITY MAP h a IiF Alder St 1 SITE PLAN I 1 /8" = 1,_0„ Q 44k, s� Q a Main St M Dayton St w v Dayton St a Q r L Maple St SITE N O F— w w F— cn z O H Q 0 z0 GENERAL NOTES 1 . IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT ALL WORK COMPLY WITH THE 2018 INTERNATIONAL BUILDING CODE, 2018 WASHINGTON ENERGY CODE, AND OTHER APPLICABLE CODES, RULES, AND REGULATIONS OF JURISDICTIONS HAVING AUTHORITY. 2. PRIOR TO COMMENCEMENT OFANY PORTION OF THE WORK, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OFANY DISCREPANCIES NOTED AMONG OR BETWEEN THE CONTRACT DOCUMENTS, OWNER -PROVIDED INFORMATION, SITE CONDITIONS, MANUFACTURER RECOMMENDATIONS, OR CODES, REGULATIONS, OR RULES OFJURISDICTIONS HAVING AUTHORITY. 3. PRIOR TO COMMENCEMENT OFANY PORTION OFTHE WORK, THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE CONTRACT DOCUMENTS, OWNER - PROVIDED INFORMATION, AND SITE CONDITIONS, INCLUDING TAKING FIELD MEASUREMENTSAS NECESSARY. 4. THE CONTRACTOR SHALLSECUREAND PAY FORALL GOVERNMENTAL PERMITS, FEES, LICENSES, AND INSPECTIONS NECESSARY FOR PROPER EXECUTION AND COMPLETION OFTHE WORK, EXCEPT FOR THE GENERAL BUILDING PERMIT. 5. THE CONTRACT DOCUMENTSARE COMPLEMENTARY AND WHAT IS REQUIRED BY ONE SHALL BE BINDING AS IF REQUIRED BYALL. 6. REPETITIVE FEATURES NOT INDICATED IN THE DRAWINGS EVERYWHERETHAT THEY OCCUR SHALL BE PROVIDED AS IF DRAWN IN FULL. 7. ALL DIMENSIONSARE TO FACE OF FRAMING OR FACE OF CONCRETE, UNLESS OTHERWISE NOTED. CONTACTARCHITECT FOR CLARIFICATIONS. 8. DO NOT SCALE THE DRAWINGS. 36"06" FOUR TOP RADIANT -TYPE ELECTRIC PATIO HEATER RADIANT -TYPE ELECTRIC PATIO HEATER r) SEATING PLAN L 1 /2" = 1'-0" LEGAL DESCRIPTION CITY OF EDMONDS BLOCK 120 D-00 - W 24.73 FT OF LOT 39 LESS N 40 FT AND LOT 40 LESS N 40 FT SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON. CODE SUMMARY BUILDING CODE: 2018 INT'L BUILDING CODE ENERGY CODE: 2018 WASHINGTON ENERGY CODE LAND USE CODE: ECC, TITLE 17 ZONING: BD1 OVERLAYS: N/A ENV. CRITICALAREAS N/A HEIGHT LIMIT: 30' STREET SETBACK: 0' REAR YARD SETBACK: 0' SIDEYARD SETBACKS: 0' PARKING REQUIREMENTS: 0 IN DOWNTOWN RETAIL CORE SNOHOMISH CO. PARCEL NUMBER #00434212003900 nnu.niu rnI In Tnn L _)u..J I LLL I LIV I I m-wiL rLl\ MI 1\ BALLAST EA. W/ MIN. 40 LB. WEIGHT, TYP. TENT ENTRY CONTACTS OWNER: RED TWIG EDMONDS LLC 117 5TH AVE S EDMONDS, WA98020 ARCHITECT: CAPSULE CONTACT: MIKE La FON 2366 EASTLAKE AVE E #403 SEATTLE, WA 98102 t: 206.395.9672 e: mike@capsule-space.net ENGINEER: HARRIOTT VALENTINE ENGINEERS CONTACT: TODD VALENTINE 1932 FIRSTAVENUE#720 SEATTLE,WA 98101 t: 206.624.4760 e: tvalentine@harriottvalentine.com CONTRACTOR: KASPER CONSTRUCTION CONTACT: JAM ES KASPER 10625 FALK RD NE BAINBRIDGE ISLAND, WA98110 t: 206.459.1507 e: kasperstairs@gmail.com w U Z u H U U Lu p Z �a 5� .a a <LL 1 \\ = O w a o �v vs P N J �a inma �v cn Z 0 r�- Lu ate m o a 0 Lu cn o = z � U U m Lu 0 0 Of J J tl ro U-) cm E E o c"I c�4 o W N J Q m cl� ry W 0— l� T CO U O 06CD CD 00 0 L j E -0 L m c a.) m E Q c _0 (D Lu (D 0 �--- Q Q = E Ln c�o O a I LLJ CD O z O LL �zz zaF-- Q Lu Q � � w w zw Z O L= w w r)l cn � cD a