APPROVED BLD RESUB1 BLD2022-0975+Mechanical_Plan+8.5.2022_9.14.42_AM+3034771SITE PLAN
D
a
Y
t
O
n
Red Twig Cafe I S
T
5th Avenue S Approved by Fi
oanvzoz2 AFM KFbtrekek
City Of Edmonds
Building Department
Work TYPE 1 HOOD
Address 117 5TH AVE S
Owner RED TWIG
Approved Date 08/08/2022
Building Official Eri.t,Csw,0-r
Permit Number BLD2022-0975
APPROVED
ALL WORK SUBJECT
TO FIELD
PLANS MUST BE
INSPECTION FOR
CODE COMPLIANCE
ON JOB SITE North
Mechanical Schedule
HD-1
8' X 48" Hybrid (S/S Front and Ends) Box Hood with Short -Cycle Make -Up Air Including 3" Air
Gap on Back and Hanging Brackets See M— 3
Type-1
Exhaust
20" x 20" x 2" Stainless Steel Filter
Hood
20" x 16" x 2" Stainless Steel Filter
Canopy Light With Tempered Globe
Grease Cup - New Style
(Pair) Stainless Steel Side CurtainsQuarter L/R -23" Top 23" High 0" Bottom
EF-1
28D DIRECT DRIVE EXHAUST FAN 115V, SINGLE PHASE,1/2 HP, UL762 LISTED
Type-1
Roof Curb for 20D-28D FLAT-17.5-17.5 See M— 4
Exhaust
10 AMP VARIABLE SPEED CONTROL for 36D
Fan
SF-1
SF7 Belt Drive Make -Up Air Fan See M-5
Roof Curb for Makeup Air Fan - FLAT
HINGE KIT
Suppression
KIDDE 8' Pre -Piped Fire Suppression Sys. Incl.: Pipe, Conduit, Nozzles, Detection Brackets,
Micro Switch, Remote Pull Station, Gas Shut Off Valve, Control Heads, Tanks and Brackets (Does
o , Permits, Final Test)
Under
Seperate
e it
1. Fire suppression and electrical under separate permit. ,
2. Must shunt gas and electrical
3. In place of a monitored fire alarm, Notification of activation
is required with signage to read "When sounding call 911" Mechanical Scope
(Fire Marshal to choose location.
T1cl t=-1
See M2 Note to paint roof
equipment and duct to
match building.
Williams Mechanical
3903 Smith Ave.
Everett, WA 90201
Install one 8' Type —I Hood,
Exhaust Fan, Supply fan,
Grease Duct, Stainless back
splash panels and gas piping
NOTE:
Fire Suppression and
Electrical Under
Permits MICOUB
Red Twig Cafe
117 5th Ave S
Edmonds, WA 98020
WM CI OF EDMONDS
VE PMENTSERVIC
DEPARTMENT
7-12-22
Restrooms
Fire Suppression and
Control Panel Under
Separate Permits
1 16" Induction Burner I
20" x 12" Make Up
Air duct down from
SF-1 on roof
Insulated per code
Entry
5th Avenue S
16' to
property line
13x13 Type-1
Welded 16 GA
Up to EF-1 on Roof
Firemaster Fire Wrap
1 30" Flat Top Griddle
133" Doublr Crepe I
Griddle
8'x4' Type-1 Hood
Minimum 6"
HD-1 Overhang of Cooking
Surface
Kitchen Area Of Work
Williams Mechanical
3903 Smith Ave.
Everett, WA 90201
Building Outline
■.TnrI m u
IN
RESUB
Red Twig Cafe
117 5th Ave S
MC OF EDMONDS
7, Y PMFNT SERVI(
=PARTMENT
12-22
Edmonds, WA 980201
Roof Supports 6' on center
--a-----------------------------------�-
Q
1" Gas Pipe Down to '
Suppression Shunt Valve by—\ r-L.7
others.
Gas Meter
16' to property line
---�I SF-1
16x16 Intake Duct
Equipment and duct
to be painted to
match building
Make Up Air Intake
Minimum 10' Clearance
from any exhaust.
Entry
5th Avenue S
Williams Mechanical
3903 Smith Ave.
Everett, WA 90201
Delta-1
NORTH 8-5-22
U B
Red Twig Cafe
117 5th Ave S
Edmonds, WA 98020
b1* M��OF EDMONDS
7n1Y PMFNT SERVI(
DEPARTMENT
7-12-22
HE EIEI MAPM' T 172REASERCOURT PHONE:440-365-1399 TOLL FREE PH:800-715-1014 WWW.HOODMART.COM
r0p rom SHOP ELYRIA, OHIO 44035 FAX: 440-365-2100 TOLL FREE FAX: 800-716-1214 SALES@HOODMART.COM
A
• •a
3"Air Gap
0
O 13x13 Grease Duct
4' Incandescent
Lig is T.Y.P.
20x12 Makeup Air
0 0
I- S
PLAN VIEW
SCALE: %'= V - 0"
DUCT OPENING ARE
RECOMMENDED
SIZES � ®L US
OPENINGS TO BE PUT LISTED
IN FIELD
ANSI/NSFZ Safety
954iHed
RESUB
u
Red Twig Cafe C OFEDMONDS
Williams Mechanical (QPMENTSERVICES
3903 Smith Ave. 11 % 5 th Ave S — �E) RTI!]
Everett, WA 90201 Edmonds, WA 98020 L7L7L7
Hood Details
HOOD MAX.O EXHAUST PLENUM Q SUPPLY PLENUM
HOOD
MODEL
LENGTH
COOKING
CONSTRUCTION
Hood Weight
TOTAL
RISERCSFM
)
TOTAL
RISER(S)
NO.
TEMP.
EXH. CFM
SUP. CFM
DIA.
QTY.
C
S.P.
WIDTH
LENG.
QTY..
CFM
S.P.
96" NOM
700
16"
1
2000
O.5'
12"
18"
2
800
0.25"
1
MVA
96"OD
Deg.
2000
1600
STAINLESS/ALVMINIZEDlbs
ME00r3hAAFRT 172 REASER COURT PHONE: 440-365-1399 TOLL FREE PH: 800-715-1014 WWW.HOODMART.COM
;Top PC=Wr ELYRIA, OHIO 44035 FAX: 440-365-2100 TOLL FREE FAX: 800-716-1214 SALES@HOODMART.COM
EF-1
FAN MODEL
I A
I B
C
D
WT.
LBS.
28D
26y"
20�/"
16Y"
19" SO.
60 LBS.
FAN
Q1 EXHAUST FAN
IT
FAN UNIT MODEL#
MODEL
TAG
CFM
S.P.
RPM
H.P.
O
VOLTS
FLA
Unit Weight
NO
28D
,�
50 lb
1
EF
28D
EF-1
2000
0.75"
1625
1/2
1
115
5.6
'�fl
MSI/NSF2
C UL US
LISTED
Safety Certified
MH29547
RESUB
HQ1 LDL 1/IART
'IM." WW 5T6r _
172 REASER COURT PHONE: 440-365-1399 TOLL FREE PH: 800-715-1014 WWW.HOODMART.COM
ELYRIA, OHIO 44035 FAX: 440-365-2100 TOLL FREE FAX: 800-716-1214 SALES@HOODMART.COM
F
B D
L
r�
L
NOT TO SCALE
FAN MODEL
A
B
C
D
wT'
LBS.
SF7
24-
22-
22-
19%'
122 LB5.
FAN 2Q SUPPLY FAN
UNINOT FAN UNIT MODEL# MODEL TAG CFM S.P. RPM H.P. O VOLTS FLA Unit Weight
1 SF 1 SF7 SFA 1600 0.25' 1028 3/4 1 115/230 - 122 lb s
�f
ANSI/NSF2
C UL US
LISTED
Safety Certified
MH29547
RESUB
Roof Structure Separate from Ceiling.
2"x12" Joist on 16" Centers
Roof Structure
CEILING STRUCTURE
Ceiling Structure separate from Roof
2"x12" Joist on 16" centers
2 load points on
CMU wall 78lbs each
Exhaust Char
3"Air
S.S. Side Curta
Concrete Block Wall
EF-1 and SF-1 Total 172lbs
supported by existing roof structure
EF-1
50lbs
Make
1-5/8th Unistrut
7A"rePer manufacturer
Make-Vp
commendation
Chamber
2 load points at front of
2' hood 78lbs each
L100W Pre —Wired
Lights
20" Baffle Grease Filter
sinless Steel Grease Cup Structural Support Comments
6'-6" - 6'-8'
A.F.F.
Equipment
provided/
installed by
others
SCALE: %"= V - O"
c �L us
LISTED
�V�/I M
MOM
Safety Certified
C AMMMMAFRT 172 REASER COURT PHONE: 440-365-1399 TOLL FREE PH: 800-715-1014 WWW.HOODMART.COM
Hem oir ELYRIA, OHIO 44035 FAX: 440-365-2100 TOLL FREE FAX 800-716-1214 SALES@HOODMART.COM
BLD2022-0975
RESUB
Aug 05 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
RESUB
20'
40" 1 Hinged Kit Access
20" Curb
Two Layers of
Firemaster Fire Wrap
See Submittale
Exhaust Cbambef�
3" Air Gap//
S.S. Side Curtain/ ,
1" Stainless Panels
with Fire Rated Wool
Insulation
Concrete Block Wall
with framing and
sheetrock
EF-1
501bs
Make -Up
Air Chamber
L100W Pre —Wired
Lights
Baffle Grease Filter
ss Steel Grease Cup
6'-6' - 6'-1"
A.F.F.
Equipment
provided/
installed by
others
SIPE VIEW
SCALE: %'= V - 0"
Make
Roof
Ceiling
Make Up Air Duct
Insulate per Code
i
MSUN0F2
C UL US
LISTED
Safety Certified
MH29547
C AMMMMAFRT 172 REASER COURT PHONE: 440-365-1399 TOLL FREE PH: 800-715-1014 WWW.HOODMART.COM
Hem ofr ELYRIA, OHIO 44035 FAX: 440-365-2100 TOLL FREE FAX 800-716-1214 SALES@HOODMART.COM
I Intake with filter I
10' minimum clearance from
exhaust
RESUB