APPROVED PLN BLD BLD2021-1245+Architectural_Plan+9.7.2021_7.04.57_PM+2396524GENERAL STRUCTURAL NOTES (THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS.) A. GENERAL 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION, AS AMENDED BY LOCAL JURISDICTION. 2. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF DOOR AND WINDOW OPENINGS. SEE MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF MISCELLANEOUS MECHANICAL OPENINGS. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM HIS WORK. STRUCTURAL DESIGN OF THE BUILDING IS BASED ON RESISTANCE TO DEAD LOADS, CODE SPECIFIED LATERAL LOADS, AND MAXIMUM EXPECTED SERVICE LOADS. NO CONSIDERATION HAS BEEN GIVEN TO LOADS WHICH WILL BE INDUCED BY ERECTION PROCEDURES. THE CONTRACTOR SHALL VERIFY, TO THE SATISFACTION OF HIMSELF AND THE OWNER, THE ABILITY OF THE STRUCTURE TO RESIST ALL ERECTION LOADS WITHOUT EXCEEDING THE ALLOWABLE STRESSES OF THE MATERIALS USED. WHERE ERECTION LOADS WOULD OVERSTRESS THE STRUCTURE, THE CONTRACTOR SHALL SUBMIT DESIGN DOCUMENTS FOR TEMPORARY BRACING AND STRENGTHENING, INCLUDING FABRICATION AND ERECTION DRAWINGS, TO THE ARCHITECT FOR REVIEW. THESE DOCUMENTS SHALL BEAR THE SEAL AND SIGNATURE OF A REGISTERED ENGINEER IN THE STATE OF WASHINGTON. THE CONTRACTOR SHALL PROVIDE, INSTALL AND IF NECESSARY REMOVE SUCH TEMPORARY WORK AS REQUIRED. 4. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED, BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE ENGINEER. 6. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER. 7. INSPECTIONS: INSPECTIONS OF THE WOOD FRAMING, THE STEEL REBAR AND WOOD FORMS FOR CONCRETE FOOTINGS & FOUNDATIONS, AND CONCRETE SLABS ARE REQUIRED PER IBC SECTION 109.3. 8. PRE -MANUFACTURED, PRE-ENGINEERED STRUCTURAL COMPONENTS SHALL BE DESIGNED BASED ON THE CRITERIA PRESENTED IN THE CONTRACT DOCUMENTS. THE COMPONENT DESIGNER IS RESPONSIBLE FOR CODE CONFORMANCE, TEMPORARY AND PERMANENT BRACING AND ALL NECESSARY CONNECTIONS, INCLUDING CONNECTIONS TO THE PRIMARY STRUCTURE, NOT SPECIFICALLY CALLED OUT ON THE ARCHITECTURAL OR STRUCTURAL DRAWINGS. SHOP DRAWINGS SHALL INDICATE THE MAGNITUDE AND DIRECTION OF ALL LOADS IMPOSED ON THE PRIMARY STRUCTURE. SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED AS NOTED PREVIOUSLY. B. DESIGN CRITERIA 1. DESIGN LOADS ROOF LIVE LOAD 25 PSF (SNOW) RESIDENTIAL LIVE LOAD (DECK) 60 PSF WIND (IBC SIMPLIFIED) 100 MPH, EXPOSURE "B", Kzt = 1.0 EARTHQUAKE (ASCE) SITE CLASS D SEISMIC USE GROUP 1 (le = 1.0) SEISMIC DESIGN CATEGORY D Ss = 1.319g, Sds = 1.055g ALLOWABLE SOIL PRESSURE 1,500 PSF AT V-6" DEPTH LATERAL EARTH PRESSURE 50 PCF PASSIVE PRESSURE 300 PCF COEFFICIENT OF FRICTION 0.4 2. LATERAL RESISTANCE SYSTEM: SHEATHED BEARING WALLS, ASCE 7-16 C. RENOVATION DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER IS EXISTING CONDITIONS DETERMINED DURING WORK VARY FROM THE EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS. EXISTING REINFORCING SHALL BE SAVED WHERE AND AS NOTED ON THE PLANS. SAW CUTTING, IF AND WHERE USED, SHALL NO CUT EXISTING REINFORCING THAT IS TO BE SAVED. A. ALL NEW OPENINGS THROUGH EXISTING WALLS, SLABS, AND BEAMS SHALL BE ACCOMPLISHED BY SAW CUTTING WHEREVER POSSIBLE. CORNERS SHALL NOT BE OVER CUT. B. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND LOCATION OF MEMBERS PRIOR TO CUTTING ANY OPENINGS. C. SMALL ROUND OPENINGS SHALL E ACCOMPLISHED BY CORE DRILLING. D. WHERE NEW REINFORCING TERMINATES AT EXISTING CONCRETE, DRILL AND EPDXY CONTRACTOR SHALL CHECK FOR DRY ROT AT ALL AREAS OF NEW WORK. ALL ROT SHALL BE REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS DIRECTED BY THE ENGINEER OR ARCHITECT. ABBREVIATIONS (THIS IS A COMPREHENSIVE LIST OF ABBREVIATIONS, SOME OF WHICH MAY NOT APPEAR ON THESE DRAWINGS.) D. FOUNDATION 1. FOUNDATION EXCAVATION, BACKFILL AND COMPACTION SHALL CONFORM TO SPECIFICATION REQUIREMENTS. THIS CONSTRUCTION WORK, INCLUDING DRAINAGE, SHORING AND SUCH OTHER RELATED WORK AS REQUIRED, SHALL BE CONDUCTED BY THE CONTRACTOR UNDER THE OBSERVATION AND DIRECTION OF THE GEOTECHNICAL ENGINEER. 2. FOOTINGS SHALL BEAR ON SOLID UNDISTURBED EARTH (CONTROLLED, COMPACTED STRUCTURAL FILL OR BOTH) AT LEAST 18" BELOW LOWEST ADJACENT FINISHED GRADE. MATERIAL TO BE COMPACTED TO 95% MINIMUM OF MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. 3. FOOTINGS MAY BE POURED IN NEAT EXCAVATIONS PROVIDED SIZE IS INCREASED 3" AT EACH INTERFACE WITH SOIL. 4. ALL FOOTING EXCAVATIONS SHALL BE HAND CLEANED PRIOR TO PLACING CONCRETE. 5. ALL ABANDONED FOOTINGS, UTILITIES, ETC. THAT INTERFERE WITH NEW CONSTRUCTION SHALL BE REMOVED. 6. CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF ALL CRIBBING, SHEATHING, AND SHORING REQUIRED TO SAFELY RETAIN EXCAVATIONS. 7. BACKFILL BEHIND ALL WALLS WITH WELL DRAINING, GRANULAR FILL MATERIAL, AND PROVIDE PERFORATED PIPE DRAINS AS DESCRIBED IN THE SOILS REPORT. BACKFILL BEHIND WALLS SHALL NOT BE PLACED BEFORE THE WALL IS PROPERLY SUPPORTED BY THE FLOOR SLAB, OR TEMPORARY BRACING. ALL FOOTINGS SHALL BE CENTERED BELOW CENTERLINE OF COLUMNS OR WALLS ABOVE, UNLESS NOTED OTHERWISE. E. CONCRETE 1. ULTIMATE STRENGTH DESIGN PER INTERNATIONAL BUILDING CODE AND ACI 318-14 2. CONCRETE FOR FOOTINGS AND SLABS -ON -GRADE SHALL CONFORM TO A 28- DAY STRENGTH OF f'c = 2500 PSI, SHALL CONTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENT PER CUBIC YARD, AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. CONCRETE EXPOSED TO EARTH OR WEATHER SHALL HAVE A 28-DAY STRENGTH OF f'c = 3000 psi. THE MINIMUM AMOUNTS OF CEMENT AND MAXIMUM AMOUNTS OF WATER MAY BE CHANGED IF A CONCRETE DESIGN MIX IS SUBMITTED TO THE ENGINEER AND THE BUILDING OFFICIAL FOR APPROVAL TWO WEEKS PRIOR TO PLACEMENT OF CONCRETE. THE CONCRETE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATES, WATER AND ADMIXTURES AS WELL AS THE WATER - CEMENT RATIO, SLUMP, CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH ACI 318, SECTION 5.3. CONTRACTOR MAINTAINS RESPONSIBILITY FOR SPECIFIED PERFORMANCE OF CONCRETE PRODUCTS. ALL CONCRETE EXPOSED TO FREEZING TEMPERATURES WHILE CURING AND ALL CONCRETE PERMANENTLY EXPOSED TO WEATHER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO IBC SECTION 1904.2. TOTAL AIR CONTENT SHALL BE IN ACCORDANCE WITH TABLE 1904.2.1 OF THE INTERNATIONAL BUILDING CODE. NO ADMIXTURES, OTHER THAN FOR AIR -ENTRAINMENT AS NOTED ABOVE, SHALL BE USED WITHOUT PRIOR REVIEW BY THE ENGINEER. ALL CONCRETE IN ELEVATED STRUCTURAL SLABS AND BEAMS SHALL BE POURED MONOLITHICALLY UNLESS SHOWN OTHERWISE OR APPROVED BY THE ENGINEER PRIOR TO PLACEMENT. 3. REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, fy = 60,000 PSI. EXCEPTIONS: ANY BARS SPECIFICALLY NOTED ON THE DRAWINGS AS GRADE 40, fy = 40,000 PSI. WELDED WIRE FABRIC: ASTM A82 AND ASTM A185, SPLICE WITH AT LEAST ONE FULL MESH. PLACE AT MID -DEPTH, OR SLIGHTLY ABOVE, OF SLAB. MATERIAL TO BE SUPPLIED IN FLAT SHEETS. 4. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI 315-02. LAP ALL CONTINUOUS REINFORCEMENT PER NOTE D.5. PROVIDE CORNER BARS AT ALL WALL INTERSECTIONS. LAP CORNER BARS PER NOTE D.5. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. 5. REINFORCING STEEL LAPS AND EMBEDMENT SHALL BE AS NOTED BELOW, UNLESS NOTED OTHERWISE: DEVELOPMENT LENGTH 48 BAR DIAM. DEVELOPMENT LENGTH, top bar* 64 BAR DIAM. LAP SPLICE LENGTH 64 BAR DIAM. LAP SPLICE LENGTH, top bar* 80 BAR DIAM. *TOP BARS ARE HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12" OF CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. ALL HOOKS SHALL BE "STANDARD" IN ACCORDANCE WITH ACI 318. REINFORCING SHALL NOT BE TACK WELDED. 6. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE 3" FORMED SURFACES EXPOSED TO EARTH (i.e. WALLS BELOW GROUND) OR WEATHER 2" SLABS AND WALLS (INTERIOR FACE) 1 1/2" 7. CONCRETE WALL REINFORCING - PROVIDE THE FOLLOWING UNLESS DETAILED OTHERWISE: 6" WALLS #4 @ 16" HORIZ. #4 @ 18" VERTICAL 1 CURTAIN @ CENTER 8" WALLS #5 @ 18" HORIZ. #5 @ 18" VERTICAL 1 CURTAIN @ CENTER 8. EPDXY GROUTED ITEMS SPECIFIED ON THE DRAWINGS SHALL BE GROUTED WITH SIMPSON SET ADHESIVE BY SIMPSON STRONG TIE, PER ER-5729, FOLLOWING MANUFACTURER'S INSTALLATION INSTRUCTIONS AB ANCHOR BOLT CL CENTERLINE (E) ACI AMERICAN CONCRETE INSTITUTE CLR CLEAR EA ADDL ADDITIONAL CMU CONCRETE MASONRY UNIT EF ADJ ADJACENT COL COLUMN EL AFF ABOVE FINISHED FLOOR CONC CONCRETE ELEC AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION CONN CONNECTION, CONNECT ELEV ALT ALTERNATE CONSTR CONSTRUCTION EMB ANSI AMERICAN NATIONAL STANDARDS INSTITUTE CONT CONTINUOUS ENGR APA AMERICAN PLYWOOD ASSOCIATION CONTR CONTRACTOR EQ APPROX APPROXIMATE; APPROXIMATELY COORD COORDINATE EQUIP ARCH ARCHITECT; ARCHITECTURAL CID COMPLETE PENETRATION ES ASSY CSK COUNTERSINK; COUNTERSUNK EW ASTM AMERICAN SOCIETY FOR TESTING & MATERIALS CTR CENTER EXP AWS AMERICAN WELDING SOCIETY CU FT CUBIC FOOT EXP JT CU IN CUBIC INCH EXT BD CY CUBIC YARD BLDG BUILDING FD BLKG BLOCKING d PENNY (NAILS) FDN BM DBL DOUBLE FF BMU BRICK MASONRY UNIT(S) DEPT DEPARTMENT FLR BOF BOTTOM OF SLAB DET DETAIL FLG BOS DIA DIAMETER (SEE SYMBOLS) FOC BOT BOTTOM DIAG DIAGONAL FOM BRG BEARING DIAPH DIAPHRAGM FOS BEAM DICA DRILLED -IN CONCRETE ANCHOR FS C STANDARD CHANNEL DIM DIMENSION FT CG CENTER OF GRAVITY DN DOWN FTG CGS CENTER OF GRAVITY OF STRANDS DO DITTO CIP CAST -IN -PLACE DWG DRAWING GA CJ CONSTRUCTION JOINT/CONTROL JOINT DWL DOWELS GALV F. CARPENTRY 1. FRAMING LUMBER SHALL BE GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD GRADING RULES FOR WEST COAST LUMBER, LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: MEMBER SIZE SPECIES GRADE MIN. BASIC DESIGN STRESS JOISTS AND RAFTERS: 2x-3x DF #2 Fb = 875 PSI JOISTS AND RAFTERS: 4x DF #1 Fb = 1000 PSI BEAMS AND STRINGERS: 6x-LRGR. DF #1 Fb = 1350 PSI POSTS AND TIMBERS 6x-LRGR. DF #1 Fc = 1000 PSI TOP AND BOTTOM PLATE AT SHEARWALLS & BEARING WALLS: DF #2 Fb = 1000 PSI STUDS, PLATES, & MISC. LIGHT FRAMING: DF #2 Fb = 875 PSI ALL LUMBER WITH A LEAST DIMENSION OF 2" (NOMINAL) SHALL BE STAMPED SURFACE -DRY AND SHALL HAVE A MOISTURE CONTENT WHEN SURFACED AND WHEN INSTALLED OF NOT MORE THAN 19 PERCENT. LUMBER WITH A LEAST DIMENSION OF 4" (NOMINAL) OR GREATER SHALL BE STAMPED SURFACE -GREEN AND AIR-DRIED TO A MOISTURE CONTENT OF NOT MORE THAN 19 PERCENT PRIOR TO ITS USE IN FRAMING THE STRUCTURE. 2. ALL WOOD PLATES IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED WITH AN APPROVED PRESERVATIVE. PROVIDE TWO LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER BETWEEN UNTREATED LEDGERS, BLOCKING, ETC., AND CONCRETE OR MASONRY. ALL METAL CONNECTORS TO PRESSURE TREATED LUMBER SHALL BE HOT DIP GALVANIZED, INCLUDING WASHERS, NAILS, SCREWS, AND SIMPSON STRONG -TIE HANGERS, STRAPS, AND PLATES, AND BOLTS LESS THAN 1/2" DIAMETER. 3. NOTATIONS ON DRAWINGS RELATING TO FRAMING CLIPS, JOIST HANGERS AND OTHER CONNECTING DEVICES REFER TO CATALOG NUMBERS OF CONNECTORS MANUFACTURED BY THE SIMPSON STRONG -TIE COMPANY, SAN LEANDRO, CALIFORNIA. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. SUBMIT MANUFACTURER'S CATALOG AND ICC REPORTS TO ARCHITECT AND ENGINEER FOR REVIEW WHEN REQUESTING SUBSTITUTIONS. ALL SPECIFIED FASTENERS MUST BE USED AND PROPER INSTALLATION PROCEDURES MUST BE OBSERVED IN ORDER TO OBTAIN ICC APPROVED LOAD CAPACITIES. VERIFY THAT THE DIMENSIONS OF THE SUPPORTING MEMBER ARE SUFFICIENT TO RECEIVE THE SPECIFIED FASTENERS. EXISTING GL GLUE -LAMINATED LOC LOCATION EACH GWB GYPSUM WALL BOARD LONGIT LONGITUDINAL EACH FACE GYP GYPSUM LSL LONG SLOTTED HOLE ELEVATION LVL LAMINATED VENEER LUMBER ELECTRICAL HDR HEADER LWC LIGHT WEIGHT CONCRETE ELEVATOR HNG HANGER EMBED, EMBEDDED, EMBEDMENT HORIZ HORIZONTAL M MISC SHAPE ENGINEER HP HP SHAPE MAS MASONRY EQUAL HS HIGH STRENGTH MATL MATERIAL EQUIPMENT HT HEIGHT MAX MAXIMUM EACH SIDE MECH MECHANICAL EACH WAY ID INSIDE DIAMETER MFR MANUFACTURER EXPANSION; EXPOSED IF INSIDE FACE MIN MINIMUM; MINUTE EXPANSION JOINT IN INCH MISC MISCELLANEOUS EXTERIOR INCL INCLUDE; INCLUDING; INCLUSIVE MO MASONRY OPENING INFO INFORMATION FLOOR DRAIN INT INTERIOR (N) NEW FOUNDATION N NORTH FAR FACE, FINISHED FLOOR JT JOINT NF NEAR FACE FLOOR; FLOOR LINE NFPA NATIONAL FOREST PRODUCTS ASSOC FLANGE K KIP = 1000 POUNDS NIC NOT IN CONTRACT FACE OF CONCRETE KO KNOCK -OUT NOM NOMINAL FACE OF MASONRY KSI KIPS PER SQUARE INCH NS NEAR SIDE FACE OF STUD NITS NOT TO SCALE FULL SIZE; FAR SIDE LAB LABORATORY FEET; FOOT LB POUND oc ON CENTER FOOTING LF LINEAL FOOT OD OUTSIDE DIAMETER LLBB LONG LEGS BACK-TO-BACK OF OUTSIDE FACE GAUGE LLH LONG LEGS HORIZONTAL OH OPPOSITE HAND GALVANIZED LLV LONG LEGS VERTICAL OPNG OPENING SPECIAL INSPECTION(S) REQUIRED FOR THIS PROJECT: 1) Installation of Brackets for the push pins 2) Soils 3) Installation of push pins City Of Edmonds Building Department ------------- Work DECK ---------------------- -------------- Address 16907 76TH AVE W Owner STUBENRAUCH Approved Date 9/27/2021 Building Official W. 71( COfka- L Permit Number; OPP OPPOSITE OSB ORIENTED STRAND BOARD PAR PARALLEL PERP PERPENDICULAR PL PLATE PLWD PLYWOOD PREFAB PREFABRICATED PROP PROPERTY PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSL PARALLEL STRAND LUMBER PT POST TENSION RD ROOF DRAIN REF REFERENCE REINF REINFORCE; REINFORCING REQ'D REQUIRED RO ROUGH OPENING SCHED SCHEDULE SEC SECTION SHT SHEET SHTG SHEATHING; SHEETING SIM SIMILAR SPA SPACING, SPACE, SPACES SPEC SPECIFICATION SQ SQUARE STD STANDARD STIFF STIFFENER BLD2021-1245 STRUCTURAL CONNECTORS ALL STRUCTURAL CONNECTORS TO BE BY SIMPSON STRONG TIE OR EQUAL. USE ZMAX/HDG HOT DIPPED GALVANIZED OR STAINLESS STEEL CONNECTORS AS A MINIMUM. USE FASTENERS GALVANIZED PER ASTM A153. ALL PRESSURE TRATED LUMBER USED SHALL BE COMPATIBLE WITH ZMAX GALV. CONNECTORES, RE: SIMPSON STRONG -TIE CORROSION INFORMATION. 8. WOOD FRAMING NOTES - THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: 8.1 ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE. MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304.9.1 OF THE INTERNATIONAL BUILDING CODE. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. 8.2 WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2x4 STUDS @ 16"oc AT INTERIOR WALLS AND 2x6 STUDS @ 16" AT EXTERIOR WALLS. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS AND UNDER THE ENDS OF ALL BEAMS. UNLESS NOTED OTHERWISE A (2) 2x8 HEADER SHALL BE PROVIDED OVER ALL OPENINGS IN 2x4 STUD WALLS AND A (3) 2x8 HEADER OVER ALL OPENINGS IN 2x6 WALLS. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORT BELOW. PROVIDE CONTINUOUS SOLID BLOCKING AT MID -HEIGHT OF ALL STUD WALLS OVER 8' IN HEIGHT. ALL STUD WALLS SHOWN ON STRUCTURAL DRAWINGS SHALL HAVE THEIR LOWER PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS AT 12"oc STAGGERED OR BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS AT 4'-0"oc, EMBEDED 7", UNO REFER TO THE STRUCTURAL PLANS AND SHEAR WALL SCHEDULE FOR REQUIRED SHEATHING AND NAILING. 8.3 NAILS SHALL BE MANUFACTURED IN CANADA OR THE UNITED STATES IN SIZES AND TYPES AS FOLLOWS, UNLESS NOTED OTHERWISE: PNEUMATIC NAILING - PLAIN SHANK, COATED OR GALVANIZED 8d = .131 DIAMETER x 2-1/2" MINIMUM LENGTH 10d = .131 DIAMETER x 3" MINIMUM LENGTHTO 16d = .131 DIAMETER x 3-1/2" MINIMUM LENGTH HAND NAILING - SINKERS, COATED 8d = 11-1/2 GAGE x 2-3/8" 10d = 11 GAGE x 2-7/8" 16d = 9 GAGE x 3-1/4" SPECIAL CONDITIONS: CONTRACTOR TO COORDINATE ALL TRADES AND VERIFY DIMENSIONS IN THE FIELD. OBTAIN OWNERS APPROVAL PRIOR TO ALL FIELD CHANGES. SEE ARCHITECTURAL DRAWINGS FOR ALL FLOOR AND WALL OPENING DIMENSIONS AND LOCATIONS, FLOOR AND WALL FINISHES, ETC. APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED BY PLANNING / � O LAI . �- Sep 23 2021 STL STEEL & AND SYMBOLS STRUCT STRUCTURAL @ AT SYM SYMMETRICAL BEAM CAMBER CENTERLINE ■ COLUMN CONTINUOUS T TOP 0 DIAMETER; ROUND 1 SECTIONS T&B TOP AND BOTTOM # NUMBER; POUND T&G TONGUE AND GROOVE m SQUARE ❑ COLUMN BELOW S100 TEMP TEMPERATURE L STRUCTURALANGLE THK THICKNESS JL DOUBLE ANGLE THRU THROUGH PLATE TOB TOP OF BEAM TOC TOP OF CONCRETE; TOP OF CURB TOF TOP OF FOOTING TOL TOP OF LEDGER ���o+ �5��0+ �o�+ Qua+ SIMPSON STRONG -TIE HOLDOWN TOM TOP OF MASONRY TOS TOP OF STEEL, TOP OF STRUCTURE TOW TOP OF WALL SIMPSON STRAP TS TUBING, STRUCTURAL TYP TYPICAL UBC UNIFORM BUILDING CODE UL UNDERWRITER'S LABORATORY, INC. UNO UNLESS NOTED OTHERWISE URM UNREINFORCED MASONRY UT ULTRA -SONIC TEST VERT VERTICAL W WIDE FLANGE WP WORK POINT WWF WELDED WIRE FABRIC U L 4� z W00 C Q 00 W LO i M W 00-r-0 Cn N Uw �o � W � < z a Q 0. LLI = zp Cl LLI ��-^^ r- 0 v! z LLI b Q r^ 0 W W RECEIVED 9/8/21 CITY OF EDMONDS DEVELOPMENT !!SEERVICES DEPARTMENT v! W H O z J NQ W z rw V.000 REVISIONS: CADD FILE: 21081 DATE: 09-02-2021 DRAWN: P. PATEL CHECKED: C. BURT S0.1 POST PER PLAN SIMPSON MPBZ SOLLEVEL---\ (2) #4 BARS WITHIN 5" OF TOP #4 TIES @ 12"oc (4) #4 VERT. o a° JO U 8 a 2 M 18"0 FIXED BASE CONNECTION SECTION 3/4" = V-0" Hardware and fasteners in contact with ■ preservative -treated wood shall be of hot -dipped zinc galvanized steel, ■ stainless steel, silicon bronze or copper. In the absence of manufacturer's recommendations a minimum of ASTM A 653 I type G185 zinc -coated galvanized steel, or ■ ■ equivalent, shall be used. I I IRC R317.3.1 IBC 2304.10.5.1 ■ oe O = PROPRIETARY PUSH PIERS: GRIP-TITE SYSTEM PER UES EVALUATION REPORT NO. 531 DRIVING FORCE NOT TO EXCEED 21.7 KIPS 18" 10'-6" 2'-0" WMIA 2'-0" 4'4" 4'4" 14'-0" 3 46-0" 30'-0" 5 PUSH PIER PLAN w/ PARTIAL FOUNDATION PLAN Q LOWER FLOOR PLAN Er__10 NOTES: 1/4" = V-0" 1.) DO NOT SCALE DRAWINGS. 2.) VERIFY ALL DIMENSIONS INFIELD. 3.) ROOM LOCATIONS ARE APPROXIMATE. U Z ; M - — V_ aCID (aco �._ � u7 CID C: rn �o(6 M 000 CN Uw �(D Q W 00 Q Z Q Q W =� Z Q W — f� W C)p 2i Q W L::.- RECEIVED 918/21 Z�ITY OF EDMONDS DEVELOPMENT VICES DEPARTMENT J L.L O O LL ry LIJ O J REVISIONS: CADD FILE: 21081 DATE: 09-02-2021 DRAWN: P. PATEL CHECKED: C. BURT S1.1 UPPER FLOOR PLAN NOTES: 1.) DO NOT SCALE DRAWINGS. 2.) VERIFY ALL DIMENSIONS INFIELD. 3.) ROOM LOCATIONS ARE APPROXIMATE. 1 /4" = 1 '-0" CU 7 a� 4D z ; M - - v- a00 taco 00 - �00 c:a) �o(6 m -�o U �o W w 0 rn QZ Qa W =� Z p �� W — r� 0 W C)p �Q w RECEIVED 918/21 CITY OF EDMONDS 5 DEVELOPMENT VICES DEPARTMENT J O O J LL W REVISIONS: CADD FILE: 21081 DATE: 09-02-2021 DRAWN: P. PATEL CHECKED: C. BURT S1.2 17'-0" T.O.F. h 9'-0" T.O.F. WEST ELEVATION NOTES: 1.) DO NOT SCALE DRAWINGS. 2.) OPENINGS LOCATIONS ARE APPROXIMATE. 17'-0" T.O.F. 9'-0" T.O.F. SOUTH ELEVATION 1/4" = 1'-01, �J NOTES: 1.) DO NOT SCALE DRAWINGS. 2.) OPENINGS LOCATIONS ARE APPROXIMATE. NORTH ELEVATION. 1/4" = 1'-0" 17'-0" T.O.F. � 9'-0" T.O.F. � Uw �o � w 00 rn QZ QQ W =� Z p �� w— �o �w C)o Q W RECEIVED 918/21 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT V ) Z O I- w J W REVISIONS: CADD FILE: NOTES: 1.) DO NOT SCALE DRAWINGS. 2.) OPENINGS LOCATIONS ARE APPROXIMATE. 1/4" = 1'-0" A1,0