FIR2022-0002+Fire_Sprinkler_Plan+1.6.2022_12.13.39_PM+2607058RETAINER STRAP . STEEL I STRUCTURE NUT BEAM CLAMP A.T.R. SIZE PER N.F. P.A. 16) RING HANGER HANGER ❑ TOP BEAM CLAMP (Fig. 4LA) Pipe Clamp for Sway Bracing �/<'/2 x 7 Machine (Hex) Boft (('Fig. 980) Universal Swivel Sway Brace Attachment 1 Pipe, Schedule 40 3 INCH LONGITUDINAL STEEL e d a ° 4 a a � HILTI HDI-P TZ CONCRETE INSERT ALL THREAD ROD RING HANGER---_ UL I FM APPROVED FOR 4" PIPE HANGER C05 CONCRETE INSERT '/ x 7 Machine (Hex) Bolt (Fig. 1001) Sway Brace Clamp / (Fig. 980) Universal Swivel Sway Brace Attachment 1 Pipe, Schedule 40 3 INCH LATERAL STEEL '/2 x 3% Kwik Bolt TZ (Fig. 1001) Sway Brace Clamp / (Fig. 980) Universal Swivel Sway Brace Attachment 1 Pipe, Schedule 40 3 INCH LATERAL CONCRETE (Fig. 4LA) Pipe Clamp for Sway Bracing 22 x 3% Kwik Bolt TZ 1. 980) Universal vel Sway Brace ichment hedule W 3 INCH LONGITUDINAL CONCRETE DEWATERING FLOOR FIRE SPRINKLER PLAN N sCuE.,a .1a HANGERLEGEND zr TO EX. SYSTEM I �'I N El Capitan a - Edmonds Landing a a. > Assisted Living Ta H Ratelco Properties U S Corporation ,,;I w Dayton st Dayton st ® Dayton S! Edmonds Short Safes y Da tan Ss Farmers Compass Course: w - 4 a a 3 Art Works Edmands4 0 4 d Austin Harp Arts r tieu:cal innrumen� m eD 2170 2nd Ave S, N Edmonds, WA 98020 Edmonds Wastewater m Treatment 3 Q a � a or Riser Material Number Quantity Size Description Manufacturer 1 1 3 G-G Butterfly Valve w/ Tamper Tyco 2 1 4 G-G Double Check Detector Assembly Deringer 3 1 3 x 2 VSR Waterf low Switch Potter Electric 4 1 2 T-T Test and Drain Valve AGF 5 1 1 1/4 Pressure Gauge Generic RISER I50 VIEW SCALE: NTS RISER SECTION VIEW o rsuLE: 1/2 N -4 FF i TS• II EX G" FP MAIN 1_' 1 SUPPLY Hydraulic Information DCCUPANCY CLASSIFICATION Ordinary Group I )ENSITY (gpm/ft2) 0.15 for 1500ft2 (Actual 1610ft2) rOTAL HOSE STREAMS 250.00 rOTAL HEADS FLOWING 16 (-FACTOR 5.6 rOTAL WATER REQUIRED 675.09 rOTAL PRESSURE REQUIRED 105.865 BASE of RISER (gpm) 675.09 BASE of RISER (psi) 105.865 ;AFETY MARGIN (psi) +19.964 (15.9%) Edmonds Park VICINITY MAP N SCALE: NONE 71z�� SHOP FLOOR FIRE SPRINKLER PLAN C1. W Walnul Sl D. 4 SCOPE OF WORK FSW WILL ADD NEW SPRINKLERS TO PROTECT THE NEW GASIFICATION ROOM, SOLIDS HANDLING ROOM, AND ID FAN ROOM. EXCLUSIONS 1, OFF HOURS AND TAXES. 2. RELOCATION OF EXISTING PIPING. 3. GWB CUTAND PATCH. 4. PRINTING OF ANY KIND. 5. WIRING OF ANY KIND. 6. REPLACE, REPAIR, OR MODIFICATION OF CEILING TILES. 7. ABATEMENT OF ANY KIND. S. STRUCTURAL VERIFICATION IF REQUIRED. DESIGN CRITERIA 1. NFPA 13 2013 ED. 2. CITY OF EDMONIDS. 3. ORDINARY HAZARD G-1 0.15/1500 S.F. WATERFLOW AVAILABILITY STATIC:127.61 PSI RESIDUAL:102.81 PSI FLOW: 2803 GPM ELEVATION: SITE LOCATION: SITE DATE:10.27-2021 INFORMATION PROVIDED BY: CITY OF EDMONDS PUBLIC WORKS FIRE PR IC UIMNM EMS Craig A. Miller 9719-0108-C Level Fire Systems West, Inc. FIRESWI1401137 Expires 1 Z/31/31 Signature Approved by Fire 01/25/2022 AFM /'<_/F�tte er 1.Replace FDC connection with locking Storz fitting 2.Monitored fire alarm is required 3.Separate permit for fire alarm 4.Fire alarm initiated by sprinkler flow and tamper switch 55ire alarm notification only (with exception of above #2) 6.New calculations to be posted in riser room 7.Subject to field inspection 2'-7�/2 FIR2022-0002 RECEIVED Jan 11 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 3 PER PLAN EX. MAIN � 10'41/2 CO r 11' -1'/2 L 1 1'-10% RISER DETAIL PLAN VIEW Jam\ ]SCALE: 1/2" = 1'-0" SPRINKLER HEADS REVISIONS GENERAL NOTES DESIGN CRITERIAAND NOTES CONTRACT NAME: EDMONDS WWTF 11 200 2N❑ AVE. S EDMONDS, WA 98020 SYM TYPE MFG MODEL ORIFICE THREAD TEMP FINISH CANOPY QTY MK DATE BY DESCRIPTION 1. ALL MATERIAL AND EQUIPMENTTO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1'-6') WHICH ARE END TO END. 3.EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA#13. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA#13. 5.PIPING SHALL BE IN ACCORDANCE WITH NFPA#13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA#13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORTTHE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER OR HIS STRUCTURAL REPRESENTATIVE. 1. ALL BRANCH LINE PIPING TO BE THREADED SCH 40 JOINED WI CAST IRON FITTINGS (UNO), 2, ALL NEW HANGERS TO BE PER HANGER DETAILS) (UNO), 3.ALL NEW HEADS AT ACOUSTICAL CEILING TO BE ON FLEX DROP FITTINGS. 4. ALL NEW CONNECTIONS TO EXISTING PIPE TO BE MADE WITH MECHAN ICAL TEE (UNO). QR 1 UPRIGHT TYCO TY313 5.6K 112" 1550 BRZ NONE 26 QR 1 DRY HSW TYCO TY3355 5.6K 1" 155' BRZ NONE 2 R / UPRIGHT/ SPRIC TYCO TY313 5.61K 1/2" 1550 BRZ NONE 3 OR 1 PENDENT TYCO TY323 S.fiK 112" 155° BRZ NONE 22 CONTRACT WITH: GENERAL MECHANICAL, INC. 2316 SOUTH STATE STREET TACOMA, VITA 98405 CONTACT. NATE CRUISE Phone: 253-606-5983 Fax: ❑ APPROVALS REQUIRED: DISTRIBUTION: AHJ AHJ 3 OWNER /ARCHITECT OWNER /ARCHITECT 1 TOTAL 53 FIRE SYSTEMS WEST 1 2 FIRE SPRINKLER PLAN 4 , dire Systems West 206 Frontage Road North, Suite C Pacific, WA. 98047 (253) 833-1248 Fax: (253) 735-0113 WACL# FIRESWI 140B1 D.C. FAB BY: Q.C. IN57ALL BY: DESIGNER DATE JOB NUMBER SHEET KEVIN RIDER 11/01/21 2-11-11859 1 OF 1