Loading...
REVIEWED FIR2022-0140+Fire_Alarm_Equipment_Specification_Sheets+12.27.2022_11.55.53_AM+3285985828 Poplar Place South RECEIVED Dec 27 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FI R2022-0140 • Seattle, WA 98144 • (206) 957-0907 • (206) 726-8160 (fax) PACIFIC Life Safety Division Fire Alarm Data Sheets For 320 5th Ave Building Fire Alarm Upgrade 12/27/22 Project Number: 27648150 Installing Contractor: Pacific Fire & Security, Inc. Site Address: 320 5th Ave S Edmonds, WA. ✓ COMMERCIAL ✓ INDUSTRIAL ✓ LIFE SAFETY ✓ COMPUTERS ✓ TELECOMMUNICATIONS ✓ ALARMS An Independent DlshibuWo/EST 828 Poplar Place South • Seattle, WA 98144 • (206) 957-0907 • (206) 726-8160 (fax) FIRE & SECURITY INC. Life Safety Division 10/26/22 Table of Contents Manufacturer Model No. Description SILENT KNIGHT 6700 FIRE ALARM PANEL SILENT KNIGHT SK-PHOTO SMOKE DETECTOR SILENT KNIGHT SK-PULL PULL STATION SILENT KNIGHT SK-MINIMON MONITOR MODULE AES 7707 RADIO COMMUNICATOR WHEELOCK HSR/SR HORN/STROBE & STROBE ✓ COMMERCIAL ✓ INDUSTRIAL ✓ LIFE SAFETY ✓ COMPUTERS ✓ TELECOMMUNICATIONS ✓ ALARMS for °+ ` Cam. An Independent ,,mt,bnW,nf EST Honeywell ®SILENT' KMGHT 6700 Addressable Fire Alarm Co The 6700 is an addressable fire alarm control panel (FACP) that can be configured to achieve an overall point capacity of up to 100 points. It has one built-in signaling line circuit (SLC), which can support 50 System SensoSK) sensors and 50 SK modules or 50 Hochiki° (SD) de s per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. It also has a built-in, dual - line POTs and IP communicator and optional cellular side -cars. The 6700 system can be enhanced by addiLespent s such as the 6860 remote annunciator which also has fmmable function buttons to help automate tasks and reducat e panel. SWIFT° wireless compatibility provides opMM detection through a Class A mesh network. It is ideal for hard - to -wire locations, buildings where newwiring is not allowed, orto provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard -wired 6700 compatible devices. SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has Form C trouble relay, and two programmable Form C relays, along with powerful features such as drift compensation, pre - trouble maintenance alert, a built-in sensor test to complywith NFPA 72 calibration testing requirements, and calibration trouble alert. FEATURES & BENEFITS • Capable of providing up to 100 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single - point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models. • Convenient field-upgradeable firmware • Integrated dual path IP and POTs communications and optional cellular side -cars for reliable backup • 6860 annunciator with a 4 x 40 large display, and 4 programmable function buttons. Free -up time spent at the panel. Program them for simple or complex tasks. • Built-in USB interface for convenient and quick programming 6700 It supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for nrintinn cvctpm rpnnrtc) the F4c)R MAI p nder, 5u�)Wxu power moaULe, ana br\ or bu aevices. • Programmable date setting for automatic and convenient Daylight Saving Time changes • Built-in dual phone Line and digital alarm communicator/ transmitter (DACT) for additional communication options • 125 software zones and 125 output groups for flexible design options 6700 Product Information SIGNAL LINE CIRCUIT (SLC) The 6700 SLC loops support multiple device types, maintenance alerts, and a built-in sensortestto complywith NFPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Trouble (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes forAC failure; solid when power systems are normal USERINTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy -to -use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. j 6700 KEYPAD PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStart° autoprogramming minimizes programming required to start new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators give you on -site access to current system programming. You can also program the system using the Honeywell Fire Software Suite (HFSS), which is Windows° based. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows° software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a Windows -based computer. ADDITIONAL INFORMATION Twisted -unshielded pair wire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signaling services. • UL Listed: S2766 • CSFM 7165-0559:050 • FDNY COA# 6250 • Seismic (CA) (pending) ORDERING INFORMATION 6100: Addressable Fire Alarm Control Panel. (Red cabinet) [d•IV, I].d1-]1441:I2U1:[dh111i67:19 6860:4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860: 4x20 LCD remote fire annunciator. 5860 is gray; 5860R is red 6855:4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories go to www.sitentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperture SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T.- Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended airspeed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-T. Photoelectric smoke detector with thermal (1350F fixed temperture) SK-PHOTOR: Photoelectric detector with remote test capability SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B21OLP: 6" mounting base 13501:4" Flangeless mounting base B20OS: Intelligent sounder base B20OS-LF: Low -frequency intelligent sounderbase B224RB: Relay base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-61B: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for theSD505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector. SD505-DUCTR:Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 1350E-150OF(OOC-370C). SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.sitentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T. Wireless Multi -criteria photoelectric smoke detector with thermal detection (135°F fixed temperture) and B51OW 4" base WSK-HEAT: Wireless Heat, (135°Ffixed temperture) and B51OW 4" base WSK-HEAT-ROR: Wireless heat, POP (135°F fixed temperture) and B51OW 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFTTools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power -limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/Parallel printer interface module for printer connection. 5895XL: Power supply with six Flexput' circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8"W x 10-3/16"H x 3"D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL -MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-I13-2: Remote reporting via the Internet. Requires a VisorAlarm° receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link forthe 6700 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode, transmitter and receiver SK-FSL: Fiber -Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. 6700 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) For a complete listing of all Overall Dimensions: 12.71" W x 15.12" H x 3.33" D Two programmable circuits which can be compliance approvals and Weight:l5lbs. individual) as: programmed y certifications, please visit www.silentknight.com. Color: Red NACs: 2.5A C 27.4VDC per circuit, power -limited (with a panel maximum current of 2.5A) Microsoft, Windows, and ENVIRONMENTAL Auxiliary Power Circuits: 2.5A @ 27.4VDC per the Windows Logo are 0 0 o Operating Temperature: 32 F to 120 F (0 C to circuit, power -limited p registered trademarks or trademarks of 49°C) Microsoft Corporation. Humidity: 0 to 93% relative humidity (non- Supports Class B (Style 4) and Class A (Style 6 or 7) condensing) configuration for the SLC Silent Knight°, Honeywell' and SWIFT' are registered trademarks of Honeywell ELECTRICAL WIRING: See the product manual for wiring details International, Inc. 6700 Primary AC: 120 VAC @ 60 Hz, 1.5ATotal Accessory Load: 2.5A C 27.4 VDC power -limited This document is not Standby Current: 165mA S intended to be used for installation purposes. We Alarm Current: 310mA tryto keep our product Battery Charging Capacity: 7 to 35AH information up -to Battery Size: 7AH max. allowed in control panel date and accurate. cannot cover all specific cabinet. Larger capacity batteries can be housed in applications or anticipate RBB accessory cabinet.. all requirements. All specifications are subject to change without notice. For Technical Support, ca11800-446-6444. For more information Learn more about Honeywell Silent Knight and other products byvisiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road N o rthfo rd, CT 06472 3516071 A 111/17 Honeywell 800-328-0103 © 2017 Honeywell International Inc. SILENT KNIGHT by Honeywell SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description SK-Photo and SK-Photo-T are plug-in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-Photo and SK-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the SK-Photo-T, dual electronic thermistors add 1350F (57°C) thermal technology to maximize detection. The SK-PhotoR is a remote test capable detector for use with the DNR/DNRW duct smoke detector. (not included) Features • Sleek, low -profile design • Base included • Reliable analog communications for trouble -free operation • Age resistant polymer housing • Dual electronic thermistor design on the SK-Photo-T • Superior EMI resistance for reliability • Simple field cleaning for code compliance • Variety of mounting options to meet any application • Dual LED indicators for 3601 visibility • Detector transmits signal to indicate maintenance is required • Optional remote LED annunciator (System Sensor@ PN RA100Z) • Plug-in mounting provides ease of installation • Tamper -proof feature available on mounting bases • Listed for use in duct applications • Rotary address switches for fast installation • UL Listed • FM Approved Specifications Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) installed in B501 base Electrical Operating Voltage: 15-32 VDC Standby Current: 300 pA @ 24 VDC Maximum Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature SK-Photo: 321— 120OF (0°C — 49°C) SK-Photo-T: 320 — 100°F (0°C — 38°C) Humidity: 10% — 93% non -condensing Other Ratings SK-Photo-T Thermal: Fixed temperature set point 1350F (57°C) Velocity: 0 — 4000 fpm (0 — 20 m/sec) • SK-Photo (Base included) Installation The SK-Photo and SK-Photo-T plug into a compatible IntelliKnight-series detector base. The SK-PhotoR is a remote test capable detector head included within the DNR (W) duct smoke detector. Compatibility SK-Photo, and SK-Photo-T are compatible with the following detector bases: B210LP 6" base (included) B501 2 wire base B224RB Relay base B224BI Isolator base B200SR Sounder base The SK-Photo, SK-Photo-T, and SK- PhotoR are compatible with the following IntelliKnight FACPs: 5820XL 5820XL-EVS 5808 5700 5600 (Rev 2.0 or higher) Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist -lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist -lock base part number B21 OLP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal -resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. ................................................................................................................................................................................................................... i Class A Optional Wiring ........................................................................................................................................................................................ !....................................................................., Wiring SK-Series Detector Mounting Bases SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350118 Rev E © 2013 Honeywell International Inc. SILENT KNIGHT by Honeywell SK-Minimon Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description The SK-Minimon is an addressable monitor modules for use with the IntelliKnight fire alarm control panels (FACPs). The SK-Minimon acts as an interface to contact devices, such as waterflow switches and pull stations. The SK-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. Features • Single contact monitor • SK-Minimon support for Class B (Style B) contact monitor wiring • Small and lightweight size allows for flexible mounting options • Rotary address switches for fast installation • UL listed r4'4� SK-Minimon Specifications Compatibility Electrical The SK-Minimon is compatible with Standby Current: 400 uA max @ the following IntelliKnight Systems: 24 VDC with comm. 5820XL Voltage Range: 15 - 32 VDC 5820XL-EVS End of Line Resistance: 47 k Ohms 5808 5700 Physical Dimensions: 2.75" W x 1.3" H x 0.5" D Weight: 1.2 oz (37 g) Environmental Operating Temperature: 32°F — 120OF (0°C — 49°C) Humidity: 10% — 93% non -condensing 5600 (Rev 2.0 or higher) SK-FFT Listings UL CSFM FM SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. IN SLC OUT Compati Wiring the SK-Minimon Other Devices o SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are FORM# 350133 Rev E subject to change without notice. For more information, contact Silent © 2013 Honeywell International Inc by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.com SILENT KNIGHT by Honeywell SK-Pull-SA and SK-Pull-DA Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 Ibs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble -free operation • Braille text on station handle • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System SK-Pull-SA E-9:E;MIa17_1 Compatibility The SK-Pull-SA and SK-Pull-DA are compatible with the following IntelliKnight FACP's: 5600 5700 5808 5820XL 5820XL-EVS Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. Class A Wring:••• Class 6 Wiring: Specifications Physical Height: 5.5" (14 cm) Wiring SK-Pull-SA & SK-Pull-DA Pull Stations Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Average Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 321— 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing Accessories BG-TR Optional trim ring. SB-1/0 Surface backbox SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover KNIGHT L3 all specific applications or anticipate all requirements. All specifications are ' subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.slientknight.com MADE IN AMERICA FORM# 350135 Rev C © 2013 Honeywell International Inc. Am W%a,a� ■ afSEC URYry CORPORATION l,LI+PVATipN 7707 Fire Subscribers In telliNet 01 Introducing a Newer, Smarter Alarm Communications Platform New Feature Highlights aes-Gorp.com • Leverages state of the art technology --Now • Applies advanced security protection n ■ Offers flexible power and configuration options NIFWA ■ Engineered for backward compatibility with legacy systems • Enables future ready capabilities ■ Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LC display, and Menu/Silence button • Improves functionality with an adaptive Graphic User Interface (GUI) for programmingvia smartphones, tablet and PCs • Plus many more... Key Benefits that Make 2.0 the Best Alarm Monitoring Solution Ever • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password protected Dealer Code ■ Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module ■ Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FRCP) without requiring an electrician onsite and without Subscriber backup battery (2) Directly from the FACP with Subscriber backup battery; or (3) Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards CAL FORE Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option, they are the ideal drop -in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network n} Burglary ❑ Subscriber -—-—- — — — — — — — —— _ oor B r — � •C r I N ► T 8] Fire A' ri 1 Subscriber I I i AE&Ne[werk Momsem.nr System B — — — — — — — — f — — Prima yAES-MulrWrt Re dyW 1 Ay Alarm I I I AA S Panel I 1 Se[o ndarY AE 5•Mu1rlNer Receluer If `� 1 I I A' B 1 B .0 Alarm Automation A _ — — Q IP Links Customer Location Mesh Radio Technology Central Monitoring Station Ala rm Pa nel&AES Su bsc ri ber 19u It i-path AES-lnfe!lrNef�• INetwork Prima ry & Secon da ry AES-i14 dKet System sends critical even[ signal delivers alarm signals via smart routing, recerves transmission In 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add -on accessory board. AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: http://aes-corp.com/products/fire/fire-marshal-resources/ How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM (UL & ULC Listed, Available Now!) IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones, with integrated onboard 7707P-88 Local Annunciator, Red Enclosure IntelliNet 2.0 Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794A AES-IntelliPro 7707P-88-ULP and integrated onboard Local Annunciator, Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones, with integrated onboard 7707P-44 Local Annunciator, Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone, 4 Supervised Zones with 7794A AES-IntelliPro 7707P-44-ULP and integrated onboard Local Annunciator, Red Enclosure 2.0 FEATURE ADD (Pending UL Review) IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies 7707P-88-M (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated 7707P-88-ULP-M onboard Local Annunciator plus MCT, Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone with Multiple Communication Technologies 7707P-44-M (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4 Zone with 7794A AES-IntelliPro, and integrated 7707P-44-ULP-M onboard Local Annunciator plus MCT, Red Enclosure 7707M-UPG IntelliNet 2.0 Fire MCT Software Upgrade 2.0 ACCESSORIES Standalone AES-IntelliPro Fire full data module add -on accessory board with 7794A firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy. •- 7706-ULF Integrated Fire Monitoring System, Red Enclosure Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module, 7788E-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, 7788F-ULP Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module, 7744F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, 7744F-ULP Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones, 7744F Red Enclosure LEGACY ACCESSORIES Standalone AES-IntelliPro Fire full data module add -on accessory board for legacy 7794 units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS 13"H x 8.5"W x 4.5"D (33cmH x 215cmW x 11.4cmD) WEIGHT 5.8 lbs (2.6 kilograms) excluding battery 131bs (5.9 kilograms) with 10 Ah battery RADIO FREQUENCY Standard Frequency Range: 450-470 MHz Contact AES for other UHF and VHF frequencies ANTENNA 2.5 dB tamper resistant antenna included, mounts on enclosure Optional remote mounting antenna available POWER INPUT AC SOURCES Transformer: Class 2 16.5V AC nominal output 1.9 A max current (40 VA MIN) ELK ELK-TRG1640, MG ELECTRONIC SALES MGT1640, or AES 1640 (not included) DC SOURCES (includes FACP) 24V DC Regulated Power Supply with Subscriber Rechargeable Battery 1.9 A max current BACKUP BATTERY 10-12 Ah, UL recognized lead acid gel cell, size based on subscriber configuration Contact Us ALARM SIGNAL INPUTS/ZONES 8 individually programmable E.O.L. type zone inputs 4+4: 4 reverse polarity input and 4 individually programmable E.O.L. type zone inputs Optional 7794A AES-IntelllPro for full data via Contact ID, Pulse, Modem lie and Modern IIla2 UL LISTINGS UL 864 10th Edition Standard for Control Units and Accessories for Fire Alarm Systerns ULC S559-04 15t Edition Equipment for Fire Signal Receiving Centres and Systems TROUBLE OUTPUT—ACK DELAY/ANTENNA CUT Form C relay, fail secure, rated 24V ❑C 1A resistive, unsupervised RESET BUTTON Located on main circuit board OPERATING TEMPERATURE 32 to 120°F (0 to 49°C) STORAGE TEMPERATURE 14 to 140°F (-10 to 600C) RELATIVE HUMIDITY 0 to 93%, non -condensing RECHARGE CAPABILITY Will charge 12V battery size from 10-12 Ali PORTS Ethernet for configuration and message communication USB access for software upgrade REMOTE ANNUNCIATOR AES Model 7740 Rernote Annunciator, supervised COMPATIBLE RECEIVERS 7705i AES-MultiNet Receiver CONFIGURATION INTERFACE Web browser capable device accessible via smartphone, tablet, laptop, or PC CURRENT CONSUMPTION Standby wl charged backup battery: 200 mA (1.2 A Transmitting) Standby + charging backup battery: 900 mA (1.9 A Transmitting - MAX) POWER OUTPUT 2 or 5 Watts Factory set ENCLOSURE MATERIAL Steel with paint finish FINISH COLOR Red VISUAL INDICATORS Front panel LCD (2 x 20 alphanumeric character backlit display) Power and Trouble LEDs (ALM, Trouble, Tx, Rx, WA) For pricing and availability or to learn more about IntelliNet 2.0, please call your local AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. Exceder Strobe, Horn Strobe, and Horn Notification Appliances Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre -wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre -wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. E_T•N Powering Business Worldwide Technical Data TDO01017EN Effective October 2014 Features • Sleek modern aesthetics • Finger slide switches • Voltage test points • Multiple voltages • 3 Audible settings • 90, 95, 99 dB • Industry leading-8 candela settings on 1 device • Wall: 15/1575/30/75/95/110/135/185 • Ceiling: 15/30/60/75/95/115/150/177 • Universal mouting base • Ceiling and wall • Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, 3.5" octal. & 4" octal. (100mm for international customers) Universal mounting base r. • _Vat a lit 1� I� Contact cover Common base for wall and ceiling with 5 mounting options • Voltage test points for quick troubleshooting and easy spot checking (wall models only) HN Series HS Series ST Series Environmentally friendly • Low current draw • Up to 9 models now in 1 appliance draw(D • 12/24VDC on a single appliance • Easy to remember model numbers O Patented Note: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range" • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F WC to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). • Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Patented Sync Protocol Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage Strobes produce 1 flash per second over the "Regulated Voltage" range Compliance UL 1971, UL 464, ULC, CSFM, FM ADA/NFPA/ANSI/OSHA RoHS 2 EATON www.eaton.com HN Series HS Series ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current() 24 VDC / 24 FWR Technical Data TDO01017EN Effective October 2014 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Currents at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current) at Anechoic 95 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 0.230 - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current) at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ,O UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Table 3. Horn Ratings per UL Anechoic Model Legend Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN = Horn HN 16-33.0 0.064 0.044 0.022 ST = Strobe HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 Table 4. Specification & Ordering Information Sync w/ DSM or Wheelock Power Model Strobe Candela Supplies 0.017 12/24 Mounting VDC) Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMBQ HSW 15/1575/30/75/95/110/135/185 X X UMB(D HSRC 15/30/60/75/95/115/150/177 X X UMB(D HSWC 15/30/60/75/95/115/150/177 X X UMB(2) Strobes STIR 15/1575/30/75/95/110/135/185 X X UMB12) STW 15/1575/30/75/95/110/135/185 X X UMB(I STRC 15/30/60/75/95/115/150/177 X X UMB(D STWC 15/30/60/75/95/115/150/177 X X UMBO Horn X X UMB� HNW X X UMB(D HNRC X X UMB@ Example: HSR HNWC X X UMB@ R = Red A = Agent Lettering (strobes only) HS = Horn Strobe AL = Alert Lettering (strobes only) C = Ceiling Mount N = No Lettering (strobes only) W = White Example 1: STRC = Strobe, Red, Ceiling Mount Example 2: HSR = Horn Strobe, Red, Wall Mount Example 3: HSW = Horn Strobe, White, Wall Mount Example 4: STW-AL = Strobe, White, Wall Mount, Alert Lettering ,O 12 VDC models feature 15 & 15/75 settings OO UMB = Universal Mounting Base ` 0 Example: HSWC EATON www.eaton.com 3 Technical Data TDO01017EN Effective October 2014 Architects and Engineers Specifications HN Series HS Series ST Series The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where multi - candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g., ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single -gang, double -gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non -synchronized flash -rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. /%A 'r .i=w WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Cooper Notification 273 Branchport Ave. Long Branch, NJ 07740 CooperN otif i cation. com © 2014 Eaton All Rights Reserved - Printed in USA Publication No. TDO01017EN Powering Business Worldwide October 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners.