Loading...
APPROVED BLD2023-0129+Architectural_Plan+1.31.2023_2.23.58_PM+3343717DENCE 20906 WOODLAKE DRIVE EDMONDS, WA 98026 OWNER KATHY OARD 20906 WOODLAKE DRIVE EDMONDS, WA 98026 (425)774-0764 KW0456@CO MCAST. N ET CONSULTANTS STRUCTURAL ENGINEER CG ENGINEERING 250 4TH AVE S, SUITE 200 EDMONDS, WA 98020 425.778.8500 FAX 778.5536 CONTACT: GREG GUILLEN, PE, SE LEGAL DESCRIPTION WOODLAKE BLK 000 D-00 - LOT 6 SUBJ ESE PUD & GEN TEL PARCEL NUMBER 00637700000600 PROPERTY INFORMATION TOTAL LOT AREA = 8,110 SQFT EX BUILDING FOOTPRINT = 1,752 SQFT PROPOSED BUILDING FOOTPRINT = NOT TO CHANGE TOTAL IMPERVIOUS SURFACE = NOT TO CHANGE SCOPE OF WORK EXISTING BEAMS BELOW THE HOME HAVE SOME DRY ROT, AND SEVERAL MEMBERS WILL NEED TO BE REPLACED BECAUSE OF THIS. THERE IS ALSO ONE MEMBER UNDER THE HOME AT THESE THAT WILL NEED TO BE REPLACED DUE TO DRY ROT. NOTE: SITE PLAN HAS BEEN PREPARED BASED ON FIELD MEASUREMENTS & COUNTY RECORDS & IS NOT A SURVEY, PROPERTY LINES ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS & UTILITY LOCATIONS. Rs N N i Zone Corner Flag Setbacks: Required Actual :20-'-.22'4' Front -- -- -----; 23'N Sides__ 12-14a°5. Rear -----------� Other ex Height Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. Ai APPROVED BY PLANNING Feb 10 2023 _------- — �360t-- SITE PLAN SCALE: 1" = 10'-0" 10 C 0 5 10 � a 20 D 88th Ave W F 207th sO n Qc 3 iO 0 208th St SW Main St --- _ /� w 2081h P\ SW f £ 2081h PI SW 3 9 D � f 209m5`Sw m. 209th PI SW N 3 m 9 U f e"' zlpm pl SW z101h PI SW D 2111h PI SW `< v o aP 7 s f �1 ° f El 212th St SW (3 O E n E f m F ,NeY VICINITY MAP N TS * = PROJECT SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE O GI ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 GUM 4 pF WASk � in ' �RASL S�Ti �`SjONAL �� 09128122 W J J I-- J J a a < a Z O m m N CO CO W D D L/) L Ln L/) W W W W W W N N N N (714 N N N N N � O a) r- 00 00 Q r-I N O N N � O O O O O Y APPROVED Q DESIGN: BEL DRAWN: ATD & LVW PLANS MUST F CHECK: GAG JOB NO: 22123.10 DATE: 06/ 1 0/22 ON JO SITE r— I f yr tamonas Buildina DeDartment DRY ROT REPAIR UNDER HOUSE ---------------------------- 20906 WOODLAKE DR --------------------------- ------------------------- OARD Approved Date 02/09/2023 Building Official rElrll/ Permit Number' BLD2023-0129 RECEIVED Feb 01 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT In 1 CO 0 N O W 00 U Y O J Z Q oo� Z Q N 0 W 5 V/ 1.� Z ID O 0 LIJ w Z O O � V / /�\j J SHEET: STRUCTURAL NOTES O G (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS DEAD LOADS: ROOF 15 PSF FLOOR 15 PSF PARTITIONS 20 PSF LIVE LOADS: ROOF (SNOW LOAD) 25 PSF RESIDENTIAL 40 PSF DECK 60 PSF STATEMENT OF SPECIAL INSPECTIONS STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER IS NOT REQUIRED. SHOP DRAWINGS SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION: 1wel Iffifill2LTA IFleolw[el01 SHOP DRAWINGS SHALL BE REVIEWED, REVISED AS REQUIRED FOR FIELD CONDITIONS, AND DATE STAMPED BY THE CONTRACTOR PRIOR TO REVIEW BY THE ENGINEER. CONTRACTOR SHALL PROVIDE (3) SETS OF SHOP DRAWINGS FOR ENGINEER'S REVIEW. ALLOW TWO WEEKS FOR SHOP DRAWING APPROVAL BY ENGINEER. ENGINEER'S SHOP DRAWING REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AND CONTRACT DOCUMENTS. MARKINGS OR COMMENTS SHALL NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR FROM COMPLIANCE WITH THE PROJECT PLANS AND SPECIFICATIONS. THE CONTRACTOR REMAINS RESPONSIBLE FOR DETAILS AND ACCURACY, FOR CONFORMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, FOR SELECTING FABRICATION PROCESSES, FOR TECHNIQUES OF ASSEMBLY, AND FOR PERFORMING THE WORK IN A SAFE MANNER. ENGINEER'S SHOP DRAWING REVIEW OF STRUCTURAL COMPONENTS DESIGNED BY OTHERS IS FOR LOADS IMPOSED ON THE BASIC STRUCTURE. THE COMPONENT DESIGNER IS RESPONSIBLE FOR CODE CONFORMANCE AND ALL CONNECTIONS TO THE BASIC STRUCTURE. SHOP DRAWINGS SHALL INDICATE MAGNITUDE AND DIRECTION OF THE LOADS IMPOSED ON THE BASIC STRUCTURE AND SHALL BE STAMPED & SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE SAME STATE AS THE PROJECT. FABRICATION SHALL BEGIN ONLY AFTER SHOP DRAWINGS BEARING THE STAMP AND SIGNATURE OF THE PROJECT ARCHITECT, ENGINEER OF RECORD, AND CONTRACTOR HAVE BEEN RECEIVED. FOUNDATIONS: SPREAD FOOTINGS SOILS REPORT: REPORT NO: NOT AVAILABLE AT TIME OF DESIGN PREPARED BY: DATED: ALLOWABLE SOIL PRESSURE: 2000 PSF (ASSUMED; TO BE FIELD VERIFIED DURING CONSTRUCTION) LATERAL EARTH PRESSURE: UNRESTRAINED: RESTRAINED: PASSIVE: COEFFICIENT OF FRICTION 35 PCF + ANY APPLICABLE SURCHARGE 50 PCF + ANY APPLICABLE SURCHARGE 300 PCF 0.35 FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR 12" OF COMPACTED STRUCTURAL FILL AS REQUIRED AND AT LEAST 18" BELOW ADJACENT EXTERIOR GRADE. ANY FOOTING ELEVATIONS SHOWN IN THE DRAWINGS REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. ACTUAL FOOTING ELEVATIONS ARE SUBJECT TO SITE CONDITIONS AND MUST THEREFORE BE ESTABLISHED BY THE CONTRACTOR. FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE, UNLESS NOTED OTHERWISE. IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D1557. BACKFILL BEHIND ALL RETAINING WALLS WITH WELL -DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. PROVIDE DAMPPROOFING AT EXTERIOR FACE OF ALL FOUNDATION WALLS EXPOSED TO EARTH PER ARCHITECTURAL SPECIFICATIONS. EXCAVATIONS AND DRAINAGE INSTALLATION SHALL BE OBSERVED BY A SOILS ENGINEER RETAINED BY THE OWNER. IF EXCAVATION SHOWS SOIL CONDITIONS TO BE OTHER THAN THOSE ASSUMED ABOVE NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. CONCRETE ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301). ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS PER CUBIC FOOT. CONCRETE STRENGTHS AT 28 DAYS (fc) AND MIX CRITERIA SHALL BE AS FOLLOWS: MAXIMUM MIN CEMENT TYPE OF CONSTRUCTION f'c* WATER/CEMENT CONTENT PER CUBIC MAXIMUM SHRINKAGE STRAIN RATIO YARD FOOTINGS 3000 PSI 0.55 5 1/2 SACK N/A THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318. ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1. *PROVIDE f'c SPECIFIED IN TABLE FOR DURABILITY REQUIREMENTS. 2500 PSI CONCRETE MEETS STRENGTH REQUIREMENTS, THEREFORE SPECIAL INSPECTION IS NOT REQUIRED. REINFORCING STEEL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy = 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE SUBMITTED. CONCRETE COVER ON REINFORCING CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" NON -SHRINK GROUT NON -SHRINK GROUT SHALL BE CEMENT -BASED WITH A MINIMUM COMPRESSIVE STRENGTH OF 5000 PSI WHEN TESTED IN ACCORDANCE WITH ASTM C-109. GROUT SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. STRUCTURAL STEEL STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", LATEST EDITION. PLATES, ANGLES, CHANNELS, AND RODS SHALL CONFORM TO ASTM A36, Fy = 36 KSI. CONTRACTOR SHALL PROVIDE CONNECTION ADJUSTMENT TOLERANCES TO SATISFY THE REQUIREMENTS OF AISC MANUAL OF STEEL CONSTRUCTION. UNLESS SPECIFIED AS STAINLESS STEEL, ALL STEEL MEMBERS, SHAPES, BOLTS, AND ACCESSORIES EXPOSED TO WEATHER SHALL BE HOT DIP GALVANIZED. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) SLEEPERS DOUG-FIR STUD 700 - LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG-FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR #2 850 - ALL POSTS AND TIMBERS DOUG-FIR #1 1200 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK 0 MIN LENGTH 8d COMMON 0.1310 2 1/2" SHANK 10d COMMON 0.1480 3" SHANK 12d COMMON 0.1480 3 1/4" SHANK 16d COMMON 0.1620 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 12.1.4.2. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. GALVANIZATION UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED ACCORDING TO THE FOLLOWING TABLE: GALVANIZATION UNTREATED WOOD CCA-C SBX ACQ-C ACQ-D CBA-A CA-B OTHER BORATE ACZA OTHER PT WOOD G90 X X X G 185 X X X X X X HDG X X X X X X STT300 X X X X X X X X G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA HDG = HOT DIP GALVANIZED SST300 = TYPE 316L STAINLESS STEEL EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. LEGEND DEFINITION SYMBOL NO DEFINITION SYMBOL — — — — —IIIIII DIRECTION OF FRAMING EXTENT OF FRAMING NATIVE SOIL==�=�=� GRANULAR FILL COLUMNS STRUCTURAL STEEL COLUMN BEARING ON BEAM P RATED SHEATHING BEAM CONTINUOUS OVER SUPPORT CONCRETE WALL e SHEAR WALL (SEE SCHEDULE) SWX O COLUMN MARK (SEE SCHEDULE) FOOTING MARK (SEE SCHEDULE) BEARING STUD WALL NON -BEARING STUD WALL HOLDOWN MARK (SEE SCHEDULE) BEARING STUD SHEAR WALL HANGER MARK (SEE SCHEDULE) O NON -BEARING STUD SHEAR WALL CMU WALL_T FLAG NOTE (SEE PLAN NOTES) STEEL MOMENT FRAME CONN. P,V ABBREVIATIONS (A) ABOVE ANCHOR BOLT HORIZ HORIZONTAL AB KIP KING POST ALT ALTERNATE ARCHITECT KSI KIPS PER SQUARE INCH ARCH MECH MECHANICAL (B) BELOW MF MOMENT FRAME BLKG BLOCKING NS NEAR SIDE ON CENTER BM BEAM OC BOT BOTTOM OPP OPPOSITE PLATE BTWN BETWEEN PL CJP COMPLETE JOINT PENETRATION PLCS PLACES POUNDS PER SQUARE INCH CLR CLEAR PSI CIVIL) CONCRETE MASONRY UNIT PSF POUNDS PER SQUARE FOOT COL COLUMN P/T POSTTENSIONED CONC CONCRETE PT PRESSURE TREATED CONN CONNECTION REINF REINFORCING CONT CONTINUOUS REQ'D REQUIRED DBL DOUBLE SCHED SCHEDULE DET DETAIL SIM SIMILAR DIM DIMENSION SOG SLAB ON GRADE EA EACH STD STANDARD ELEV ELEVATION SW SHEAR WALL EXIST EXISTING TOC TOP OF CONCRETE EXP EXPANSION TOS TOP OF STEEL FLR FLOOR TOW TOP OF WALL TYPICAL FDN FOUNDATION TYP FTG FOOTING FAR SIDE UNO UNLESS NOTED OTHERWISE FS VFY VERIFY FH GLB FULL HEIGHT GLUE -LAMINATED BEAM VIF VERT VERIFY IN FIELD VERTICAL ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 GUM 4 pF WASk � Si stir ONAL� 0912BI 22 a a � < a F-- F-- � � z :22 � 2 :2 O m m N co m �= Lu =) =) cn cn = cn cn ~ H H H H U :E 2 2 :E 0 = = = = LLI w w w w w a a a a N N N N N LL1 N N N N N � O Ol I_ 00 00 Q r-I N O N N n n (10 O O O O O Y Q DESIGN: BEL II CHECK: GAG III JOB NO: 22123.10 DATE: 06/10/2211 RECEIVED Feb 01 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT LJ 0 Z LIJ W uj 0 i 0 0 N SHEET: V / 0 Z 0 0 W Simi V 0 Z J NQ U D/'�/ LL V / w a z w O GI EXIST 10"0 CONIC FOUNDATION REMOVE EXISTING 4x10 & REPLACE W/ PT 412 HF#2. PROVIDE BUILT UP NAILER AT DECK TO MATCH EXISTING/MAINTAIN LEVELNESS. NOTCH BEAM (2) 2X RIM I DECK IS 49" ABOVE GRADE AT HIGHEST LOCATION EXIST I 2x6 @ 16" OCI PRIOR TO INSTALLATION OF 1 NEW PT 4x12 BEAM REMOVE 1 00 oo EXISTING BRACKETS (4 PLACES) 1 AS REQUIRED. PROVIDE NEW ANGLE SEAT PER DETAIL 2 x x EXTERIOR DECK APPROX T-6" ABOVE GRADE CONTRACTOR TO PROVIDE TEMP SHORING AS REQUIRED PRIOR TO REPLACEMENT OF BEAM FOUNDATION PLAN EXTERIOR DECK APPROX T-6" ABOVE GRADE I �2� I I I EXIST 2x10 @ 16" OC VAULTED LIVING ROOM EXISTING (2) 2X RIM TO BE REMOVED & REPLACED W/ TREATED LIKE KIND CONTRACTOR TO PROVIDE TEMP SHORING AS REQUIRED PRIOR TO REPLACEMENT OF BEAM, TYP. REMOVE EXISTING 4x10 AND REPLACE W/ TREATED LIKE KIND. PROVIDE BUILT UP NAILER AT DECK TO MATCH EXISTING. NOTCH BEAM AT (2) 2X RIM. CANTILEVER BEAM 14" PAST EXISTING POST OR EXTENT OF EXIST WOOD ROT PT 4x4 HF#2 W/ V-0" x V-0" CONCRETE PIER BLOCK. PROVIDE SIMPSON COLUMN CAP CCQ44SDS2.5 CONTRACTOR TO PROVIDE TEMP SHORING AS REQ'D PRIOR TO REPLACEMENT OF BEAM 6x12 OUTRIGGER PORTION TO MATCH ADJACENT EXISTING BEAM DIMENSIONS. ONLY CUT BACK TO FACE OF SIDING REMOVE EXISTING BEAM AND REPLACE W/ 6x12 WESTERN CEDAR #1 (FB = 975.0 PSI) FOUNDATION PLAN NOTES: 2'-0" 0 2'-0" 4'-0" ELEVATION SCALE: 1/2" = V-0" 1'-0" 0 2'-0" i» m 0 in ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 J J F-- J J a a < a z O m m N om m w D D W N N er cn cn U W w w w w w N N N N N NLLI N N N N ~ O Ol I- 00 00 4'-0" Q r-I N O n N n N (10 O O O O O 09128/ 22 1. CONTACT ENGINEER IF ANY OTHER AREAS OF DRY ROT IS DISCOVERED DURING CONSTRUCTION. Y AiCEEVIDE SIMPSON H1 CLIP FOR EVERY OTHER JOIST AT NEW/REPLACED BEAMS. 3. - - - - - - INDICATES TEMPORARY SHORING. DESIGN: BEL 4. EXISTING DECK RAILING HEIGHT IS 39" ABOVE WOOD DECK WITH 4x4 POSTS @ 4'-0" OC. SCOPE OF WORK INVOLVES REPLACEMENT OF DRY ROTTED MEMBERS WITH LIKE KIND AND ADDITION OF PIER BLOCK FOOTINGS DRAWN: ATD & LVW CHECK: GAG AS NEEDED. 5. NO WORK WILL BE DONE TO THE EXISTING GUARDRAILS FOR THE DECK. ALL WORK IS BELOW THE DECK. JOB NO: 221 23.1 0 DATE: 06/ 1 0/22 L6 x 6 x 3/8 x 0'-8" W/ (2) 1/2" 0 x 4" LAG SCREW W/ 2" END DISTANCE NON -SHRINK GROUT NOTE: VERIFY THICKNESS AT EACH POLE FOOTING EXIST JOIST OF HOUSE EXIST FLOORING SIMPSON H1 EA JOIST BEAM PER PLAN ROUTER BM AS REQUIRED FOR BOLT HEAD LEVELING NUT 1/2"0 F1554 GR36 ANCHOR ROD SET IN HILTI HIT-HY 200 W/ 4" EMBED EXIST CONC POLE FOOTING NOTCH BOTTOM OF BEAM AS REQUIRED TO MAINTAIN EXISTING FLOOR LEVEL. LENGTH OF NOTCH TO MATCH WIDTH OF CONCRETE FOUNDATION L6 x 6 x 3/8 x 0'-8" W/ (2) 1/2"0 x 4" LAG SCREW W/ 3" END DISTANCE w w Lu = w � U Lu ON w w 0 0 Q Q mm po [V N `i EXIST JOIST EXIST FLOORING SIMPSON H1 EA JOIST BEAM PER PLAN. RIP DEPTH / AT SUPPORT ONLY TO FIT BETWEEN EXIST JOIST AND - ANGLE m ROUTER BM AS REQUIRED FOR BOLT HEAD 5/8" DIA TITEN HD ANCHOR W/ MIN 4" EMBEDMENT EXIST CONIC POLE FOOTING Lf In Q RECEIVED Feb 01 2023 CITY E O DEVELOPMENT SERVICES DEPARTMENT 0 Lf n 1 I Co Ld 0 N U La 00Z C) Q 0 Z J Q 0 O Ld La 50 w /� 0 Z 0 p O Lf O 0 Q Q O N w O 1 Ld SHEET: S2ml SECTION SCALE: 1 1/2" = V-0" SECTION SCALE: 1 1/2" = V-0" ELEVATION SCALE: 1 1/2" = V-0"