Loading...
APPROVED BLD PLN RESUB1 BLD2021-0524+Architectural_Plan+6.10.2021_12.37.29_PM+2243033540FIRPL ER�Y i / �QOP � ADJACENT r � � � � O EDGE OF CURS � EDGE OF DRIVEWAY � � — — i — REAR YARD SETBACK 25' — — — i I � � N / 1 / .......... PROPERTY LINE ± 99.70' � - � - � - i 180'/ 1 --------------- ,_ SITE PLAN SCALE 22X34 1" = 10'-0" SCALE 11X17 1" = 20'-0" VICINITY MAP � FROM GOOGLE MAPS " m Pines n Pllx 6t _ - PineStree! `" �+ Playfield a Fyrsylh LII SyVi Ln Fr 6l QThe Contineraal - 90 Flt PI, Edmonds. WA 9802�] a �mw�, D �,,.�, � IN - KaiserPerrnenenre `� Authad2ed Agenl E""� "b11fpW Cfe� -,. � �. PROJECT INFORMATION naado�.�� c.,�„�.,��„o„ OWNER BUI ALLISON M Sz CASEYX JURISDICTION EDMONDS PARCEL NUMBER 00536000000600 ZONING RS-6 YEAR BUILT 1965 LOT AREA 6098 SQ-FT SENSITIVE AREA N/A PROJECT DESCRIPTION INTERIOR REMODEL TO EXISTING SFR LEGAL DESCRIPTION OLYMPIC LANE BLK 000 D-00 -LOT 6 YARD CALCULATIONS REAR YARD = 25 FEET REQUIRED REAR YARD = 25' FRONT YARD = 20 FEET REQUIRED FRONT YARD = 20' SIDE YARD = 5 FEET REQUIRED SIDE YARD = 5' AREA TABULATIONS CONDITIONED SPACE BASEMENT LEVEL 1101 SQ-FT MAIN FLOOR LEVEL 1727 SQ-FT TOTAL 2828 SQ-FT UNCONDITIONED SPACE GARAGE 498 SQ-FT TOTAL 498 SQ-FT TOTAL AREA 3326 SQ-FT 0' 2 z 5' 10' 2 0' LOT COVE RAG E TOTAL LOT AREA PRIMARY STRUCTURE FRONT DECK BACK DECK TOTAL LEGEND PROPERTY LINE OF PROPOSED PROJECT PROPERTY LINE OF ADJACENT PROPERTIES CONTOUR LINE - 5' ELEVATION CHANGE EXISTING STRUCTURE W/ INTERIOR RENOVATION EXISTING STRUCTURE EDGE 0� CONCRETE --- --- ROOF OUTLINE — — — PROPERTY SETBACK APPROVED BY PLANNING �� ��;� Jul 06 2021 APPROVED PLANS MUST BE ON JOB SITE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE SHEET INDEX C1.1 SITE PLAN � PROJECT INFO 6098 SQ-FT A1.1 1687 SQ-FT 191 SQ-FT A2.1 233 SQ-FT A2.2 2111 SQ- FT ALLOWABLE LOT COVERAGE = 6098 * 35% = 2135 SQ-FT PROPOSED LOT COVERAGE = 2111 SQ-FT (OK) Zone RS-6 Corner Flag Setbacks: Required Actual Front -- 20' � : r-------- 20' Sides r----------- ' 5' -------- ' 6', 7' Rear r-----------� 15' � :-----------� ,--------- � 23' �-----------� Other 25 Height GENERAL NOTES Sz WINDOW � DOOR SCHEDULE BASEMENT FLOOR PLANS MAIN FLOOR PLANS A5.1 ARCHITECTURAL DETAILS City Of Edmonds Building Department Work REMODEL ----------------------------------------------- Address 540 FIR PL Owner�----------------------------BUI------- Approved Date 6/28/2021 Building Official � w• � Permit Number BLD2021-0524 w Z J d W � Z � Z O m O � � � U � w W O 0 a U uJ N N O Q � o � 0 0 o /' YEN DESIGN INC. 206.432.1111 WWW.YENDES.COM APPROVAL STAMP ENGINEER STAMP Cn w 0 X O W Z U � O � o Q � � � � z � w LLB a o � � _� J Q � � w � � _ � o � Q L� m � �w Z Q Z � W � U r� V J O RESUB Jun 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOB NO. 20-231 HALF SCALE 11x17 FULL SCALE 22x34 SHEET C1.1 GENERAL NOTES CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING THE WORK, WORK SHALL COMPLY WITH THE FOLLOWING CODES; 2018 INTERNATIONAL RESIDENTIAL CODE 2018 WASHINGTON ENERGY CODE OTHER CODES APPLICABLE BY JURISDICTION, AIR SEALING: 1, ALL PLUMBING, ELECTRICAL, AND HVAC PENETRATIONS IN FLOOR, WALLS, AND CEILINGS ARE CAULKED AND SEALED, 2, WHERE PENETRATIONS NEED A FIRESTOP, DISCUSS WITH BUILDING OFFICIAL, 3, ELECTRICAL OUTLET AND LIGHT SWITCH BOXES ON EXTERIOR WALLS MUST BE SEALED AT THE BACK OF THE RECEPTACLE OR SEALED WITH FACEPLATE GASKETS, 4, SEAL RIM JOIST BETWEEN HEATED FLOORS OR USE PRODUCT LIKE "TYVEK" ON EXTERIOR, 5, VAPOR BARRIER SHALL BE EITHER FACE STAPLED BATTS, 4 MIL, VISQUEEN OR AN APPROVED VAPOR BARRIER PAINT, SEPARATION BETWEEN DWELLING AND GARAGE/CARPORT; a, NO SEPARATION REQUIRED IF ENTIRELY OPEN ON 2 OR MORE SIDES AND NO ENCLOSED USES, (OPEN DECKS ABOVE ARE OKAY, NON -RATED WALLS AND OPERABLE WINDOWS BETWEEN THE DWELLING AND CARPORT ARE OKAY), b, MINIMUM 1/2" GWB ON GARAGE/CARPORT SIDE OF WALLS REQUIRED FOR ALL GARAGES/CARPORTS NOT COVERED BY 1A ABOVE, c, 1-HOUR FIRE RATED WALL REQUIRED IF LESS THAN 5 FEET FROM PROPERTY LINE INO OPENINGS ALLOWED LESS THAN 3' FROM PROPERTY LINE, 25% MAXIMUM OPENINGS BETWEEN 3' AND 5' TO PROPERTY LINEJ, OVERHANGS MUST BE A MINIMUM 2' FROM PROPERTY LINE, EXCEPT STEEL GUTTER ALLOWED CLOSER AND 5/8" GWB SHEATHING REQUIRED ON UNDERSIDE WHEN 5' OR LESS FROM PROPERTY LINE, EGRESS WINDOWS: REQUIRED FOR 1 WINDOW/BEDROOM OR SLEEPING AREA (BELOW 4TH FLOOR) AND 1 WINDOW/BASEMENT, a, MIN, NET CLEAR AREA = 5,7 SQ, FT., (MIN, 3'0" x 4'6" IF DOUBLE HUNG OR 4'0" x 3'6" WINDOW IF SLIDER), 5,0 SQ, FT. IF SILL HEIGHT IS WITHIN 44" OF GRADE (ABOVE OR BELOW), b, MIN, NET CLEAR OPENING WIDTH = 20"; MIN, NET CLEAR OPENING HEIGHT = 24" c, MAX, SILL HEIGHT = 44" IONS PERMANENTLY INSTALLED STEP WITH MAX, 8" RISE AND MIN, 9" RUN OKAY FOR EXISTING BEDROOMS), REQUIRED GLAZING FOR HABITABLE ROOMS; a, MIN, GLAZED EXTERIOR OPENING AREA = 8% OF FLOOR AREA, b, GLAZED OPENINGS NOT REQUIRED WHERE PERMANENTLY INSTALLED ARTIFICIAL LIGHT IS PROVIDED, c, OK IF OPENINGS ARE BELOW DECK &ROOFED PORCHES w/MIN, CEILING HEIGHT OF 7 FT. (LONG SIDE 65% OPEN), MECHANICAL/VENTILATION; REQUIRED FOR HABITABLE ROOMS OF ADDITIONS AND ALTERATIONS MORE THAN 500 SQ, FT, OR THAT INCLUDE A KITCHEN, BATHROOM AND OTHER AREAS WHERE COOKING ODOR OR EXCESS WATER VAPOR WILL BE PRODUCED, a, MIN, 50 CFM FOR BATHROOM AND LAUNDRY; MIN, 100 CFM FOR KITCHEN, b, MIN, AIR INTAKE OPENINGS = 4 SQ, IN, PER ROOM, c, WHOLE HOUSE FAN MUST OPERATE AS SPECIFIED IN IRC M1507,3 SMOKE ALARMS; REQUIRED INSIDE AND OUTSIDE OF SLEEPING AREAS AND ON ALL FLOORS, DIRECT WIRING IS REQUIRED FOR SMOKE DETECTORS, UNLESS REMOVAL OF INTERIOR WALL OR CEILING FINISHES IS NECESSARY TO INSTALL THE WIRING, CARBON MONOXIDE ALARMS: REQUIRED OUTSIDE SLEEPING AREAS AND ON ALL FLOORS, UNLESS WORK ONLY INVOLVES EXTERIOR SURFACES OF THE BUILDING, STAIR REQUIREMENTS; (APPLIES TO ALL R-3 STAIRS AND R-2 PRIVATE STAIRWAYSJ: a, MIN, WIDTH = 36" b, MAX, HEIGHT/RISE = 7-3/4"; MIN, TREAD RUN = 10" c, MIN, HEADROOM = 6'8" d, HANDRAIL 34"-38" ABOVE TREAD NOSING (RETURN ENDS) e, HANDRAIL GRASP DIMENSION; MIN, 1-1/4", MAX, 2" f, WINDING STAIRS: 1� MIN, TREAD RUN AT NARROWEST POINT = 6" 2, MIN, TREAD RUN 12" FROM NAORROWEST POINT = 10" g, SPIRAL STAIRS; 1, MIN, CLEAR WALKING AREA WIDTH = 26" 2, MIN, TREAD RUN 12" FROM NARROWEST POINT = 7-1/2" / MAX, RISER HEIGHT = 9-1/2" 3, MIN, HEADROOM = 6'6" CEILING HEIGHT IN ADDITIONS AND ALTERATIONS: a, MIN, 7'0"; FOR NEW CONSTRUCTION OR ADDITIONS b, MIN, 6'4": IF BUILDING WAS IN EXISTENCE PRIOR TO 10/17/79 IEEE DR 23-2008 FOR SPECIFICS), c, ROOMS WITH SLOPED CEILINGS REQUIRE MINIMUM CEILING HEIGHT IN 1/2 OF THE AREA. (PORTIONS OF THE ROOM WITH CEILING HEIGHT LESS THAN 5 FT. DO NOT COUNT IN TOTAL AREAJ, INSULATION: L FACED BATTS ARE LAPPED AND FACE STAPLED AT FRAMING MEMBERS, 2, ALL EXTERIOR WALL CAVITIES ARE FILLED WITH UNCOMPRESSED INSULATION, INCLUDING ALL CAVITIES ISOLATED DURING FRAMING, WIRING, AND PLUMBING, 3, ALL RECESSED FIXTURES IN EXTERIOR WALLS HAVE RIGID BOARD INSULATION BEHIND THEM, 4, UNDERFLOOR INSULATION IS SUPPORTED BY LATH, TWINE, OR OTHER NON -COMPRESSING MEANS, 5, ATTIC ACCESS IS BAFFLED, WEATHER-STRIPPED AND INSULATED, FOUNDATION LOCATION: PROPERTY CORNERS MUST BE ACCURATELY DETERMINED AND INDICATED ON SITE FOR FOUNDATION INSPECTION, A SURVEY MAY BE REQUIRED, FENCE LOCATIONS WILL NOT BE ACCEPTED AS ESTABLISHING PROPERTY CORNERS, OTHER REQUIREMENTS: a, GUARDRAILS; MIN, 36" HT. MAX, 4" SPACING BETWEEN INTERMEDIATE MEMBERS I42" MIN, HT. FOR R-2 EXTERIOR), b, FOORINGS: BOTTOM MIN, 12" BELOW GRADE, TOP OF FOUNDATION WALL MIN, 6" ABOVE GRADE, c, CONRETE SLABS ON GRADE: 3-1/2" MIN, THICKNESSES, d, PIER BLOCKS: MIN, 12" X 12" SIZE; RESTING ON CONCRETE PAD MIN, 12" BELOW GRADE, e, FOUNDATION WALLS; PROVIDE ONE j1) #4 REBAR TOP AND BOTTOM AND AT ALL WINDOWS/DOOR OPENINGS, LIMIT 4' MAX, BACKFILL, f, FOUNDATION ANCHOR BOLTS; MIN, 1/2" x 10", 6 FT, ON CENTER MAX, WITH TWO I2J BOLTS PER PIECE OF PLATE AND AT LEAST ONE j1) BOLT WITH 12" AT END OF EACH PIECE (REQUIRED FOR NEW CONSTRUCTION), 9, ALL STRUCTURAL SOFTWOOD PLYWOOD, PARTICLE BOARD, WAFER BOARD, AND OSB BOARD ARE STAMPLED WITH EXPOSURE '1' OR 'EXTERIOR', h, WATER HEATER STORAGE TANK LABELED AS MEETING 1987 NAT'L APPLIANCE ENERGY CONSERVATION ACT, ASHRAE STANDARD 90A-1980 INSULATION TO R-16 OR R-10 PAD IF LOCATED OVER UNINSULATED SLAB, i, INSULATE HOT AND COLD WATER PIPES TO R-3 IN UNHEATED AREAS, j, SHOWER REGULATOR TO LIMIT HOT WATER DISCHARGE TO 2,5 GPM k, WOODSTOVES AND FIREPLACES HAVE TIGHT FITING DOORS( OUTSIDE COMBUSTION AIR DUCTED TO FIREBOX WITH ACCESSIBLE DAMPER, MIN 6 SQ IN FREE VENT AREA, TIGHT FITTING FLUE DAMPERS REQ'D, I, ALL GAS AND OIL COMBUSTION APPLIANCES HAVE A DIRECT VENT OR FORCED DRAFT VENTING, m, RECESSED LIGHTS ARE I,C, RATED, DOUBLE WALL CAN LIGHTS OR WITHIN SEALED WPGWB BOX -IN, n, CONTRACTOR TO PROVIDE I1J 16"x24" MINIMUM CRAWL SPACE ACCESS INTO NEW CRAWL SPACE AREA THAT IS ACCESSIBLE FROM EITHER THE OUTSIDE OR FROM THE EXISTING CRAWLSPACE AREA, OTHERWISE CONTRACTOR IS TO PROVIDE I1) 18"x24" MINIMUM CRAWL SPACE ENTRANCE THROUGH MAIN LEVEL FLOOR FRAMING THAT ACCESSES NEW CRAWL SPACE AREA, o, A CERTIFICATE IS REQUIRED TO BE POSTED WITHIN 3' OF THE ELECTRICAL PANEL PER WSEC R401,3 AND INCLUDE THE FOLLOWING; PREDOMINATE R-VALUES, U-VALUES OF FENESTRATION, RESULTS FROM DUCT SYSTEM AND BUILDING ENVELOPE AIR LEAKAGE TESTING, AND EFFICIENCIES OF HEATING/COOLING/WATER HEATING EQUIPMENT, p, A MIN OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN INTERIOR AND EXTERIOR LIGHTING FIXTURES MUST BE HIGH -EFFICIENCY LAMPS PER WSEC R404,1 INSULATION CLIMATE ZONE 5 AND MARINE-4 FENESTRATION U-FACTOR jkl 0,30 SKYLIGHT U-FACTOR Ike 0,50 GLAZED FENESTRATION SHGC (b,el NR CEILING R-VALUE Ikl 49 WOOD FRAME WALL R-VALUE Icl 21 INT MASS WALL R-VALUE Idl 21/21 FLOOR R-VALUE 30 BELOW -GRADE WALL R-VALUE le,c) 10/15/21 INT + TB SLAB R-VALUE &DEPTH Ig,hl 10, 2FT FOR SI: 1 FOOT = 304,8 MM, CI =CONTINUOUS INSULATION, INT = INTERMEDIATE FRAMING, a, R-VALUES ARE MINIMUMS, U-FACTORS AND SHGC ARE MAXIMUMS. WHEN INSULATION IS INSTALLED IN A CAVITY WHICH IS LESS THAN THE LABEL OR DESIGN THICKNESS OF THE INSULATION, THE COMPRESSED R-VALUE OF THE INSULATION FROM APPENDIX TABLE A101,4 SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED IN THE TABLE, b, THE FENESTRATION U-FACTOR COLUMN EXCLUDES SKYLIGHTS, THE SHGC COLUMN APPLIES TO ALL GLAZED FENESTRATION, c, "10/15/21 +TB" MEANS R-10 CONTINUOUS INSULATION ON THE EXTERIOR OF THE WALL, OR R-15 CONTINUOUS INSULATION ON THE INTERIOR OF THE WALL, OR R-21 CAVITY INSULATION PLUS A THERMAL BREAK BETWEEN THE SLAB AND THE BASEMENT WALL AT THE INTERIOR OF THE BASEMENT WALL, "10/15/21 +TB" SHALL BE PERMITTED TO BE MET WITH R-13 CAVITY INSULATION ON THE INTERIOR OF THE BASEMENT WALL PLUS R-5 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR OF THE WALL, "TB" MEANS THERMAL BREAK BETWEEN FLOOR SLAB AND BASEMENT WALL, d, R-10 CONTINUOUS INSULATION IS REQUIRED UNDER HEATED SLAB ON GRADE FLOORS, SEE R402,2,9,1, e, THERE ARE NO SHGC REQUIREMENTS IN THE MARINE ZONE, f, RESERVED, g, RESERVED, h, RESERVED, i, THE SECOND R-VALUE APPLIES WHEN MORE THAN HALF THE INSULATION IS ON THE INTERIOR OF THE MASS WALL, j, RESERVED, k, FOR SINGLE RAFTER- OR JOIST -VAULTED CEILINGS, THE INSULATION MAY BE REDUCED TO R-38, I, RESERVED, m, INT. (INTERMEDIATE FRAMING) DENOTES STANDARD FRAMING 16 INCHES ON CENTER WITH HEADERS INSULATED WITH A MINIMUM OF R-10 INSULATION, n, LOG AND SOLID TIMBER WALLS WITH A MINIMUM AVERAGE THICKNESS OF 3,5 INCHES ARE EXEMPT FROM THIS INSULATION REQUIREMENT, o, WHERE EXISTING FRAMING CAVITIES ARE EXPOSED DURING CONSTRUCTION, THE CAVITIES MUST BE FILLED TO FULL DEPTH WITH GATT INSULATION OR INSULATION HAVING AN EQUIVALENT NOMINAL R-VALUE OF R-15 AT 2x4 WALLS OR R-21 AT 2x6 WALLS PER WSEC 503,1,1 MECHANICAL/VENTILATION AREAS TO BE EXHAUSTED EXHAUST RATES KITCHENS 100 CFM INTERMITTENT OR 25 CFM CONTINUOUS BATHROOMS/TOILET ROOMS, LAUNDRY MECHANICAL EXHAUST ROOMS,INDOOR SWIMMING POOL ROOMS, SPA CAPACITY OF 50 CFM ROOMS. INTERMITTENT OR 20 CFM CONTINUOUS • • • • � � � • • '� • • NUMBER OF BEDROOMS DWELLING UNIT FLOOR AREA (SQUARE FEET( 0-1 2-3 4-5 6-7 >7 AIRFLOW IN CFM <1500 30 45 60 75 90 1501-3000 45 60 75 90 105 3001-4500 60 75 90 105 120 4501-6000 75 90 105 120 135 6001-7500 90 105 120 135 150 >7501 105 120 135 150 165 INTERMITTENT WHOLE -HOUSE MECHANICAL VENTILATION RATE FACTORS M1507.3.3�21 .. ,- 1. LOCAL EXHAUST SHALL BE POVIDED IN EACH KITCHEN, BATHROOM, WATER CLOSET, LAUNDRY ROOM, INDOOR SWIMMING POOL, SPA, AND OTHER ROOMS WHERE WATER VAPOR OR COOKING ODOR IS PRODUCED, LOCAL EXHAUST SYSTEMS SHALL BE DESIGNED TO HAVE CAPACITY TO EXHAST THE MINIMUM AIR FLOW RATE DETERMINED IN ACCORDANCE WITH TABLE IRC M1507,4, • KITCHENS = 100 CFM INTERMITTENT OR 25 CFM CONTINUOUS, • BATHROOMS/TOILET ROOMS, LAUNDRY ROOMS, INDOOR SWIMMING POOL ROOMS, SPA ROOMS = 50 CFM INTERMITTENT OR 20 CFM CONTINUOUS, • EXCEPTION: WHERE A RANGE HOOD OR DOWN DRAFT EXHAUST FAN IS USED TO SATISFY THE LOCAL EXHAUST REQUIREMENTS FOR KITCHENS, THE RANGE HOOD OR DOWN DRAFT EXHAUST SHALL NOT BE LESS THAN 100 CFM AT ,10 INCHES WATER GAUGE, • LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS, 2, WHOLE -HOUSE VENTILATION USING EXHAUST FANS MUST COMPLY WITH IRC M1507,3,4, EACH HABITABLE SPACE SHALL BE PROVIDED WITH OUTDOOR AIR INLETS OR OPERABLE WINDOWS WITH AN OPENABLE AREA NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH 10 CFM OF OUTDOOR AIR REQUIRED BY TABLE M1507,3,3I1). WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS, DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING, 3, MAXIMUM HEAT EQUIPMENT OUTPUT FOR THIS HOME IS XXXX BTU/HR PER THE WSEC HEATING SYSTEM SIZING WORKSHEET, 4, A DUCTLESS SPLIT SYSTEM HEAT PUMP IS REQUIRED TO COMPLY WITH THE WSEC CREDIT REQUIREMENT SELECTION OF 3b, 5, DUCTS MUST BE LEAK TESTED IN ACCORDANCE WITH WSU RS-33 USING THE MAXIMUM DUCT LEAKAGE RATES SPECIFIED, DUCT TIGHTNESS MUST BE VERIFIED BY EITHER APOST-CONSRUCTION TEST OR ROUGH - IN TEST PER WSEC R403,3,3, TOTAL LEAKAGE MUST BE LESS THAN OR EQUAL TO 4 CFM PER 100 SO -FT OF CONDITIONED FLOOR AREA WHEN TESTED AT A PRESSURE DIFFERENTIAL OF 0,1" W,G. I25 PAJ ACROSS THE ENTIRE SYSTEM, 6, PER IRC M1503,41 IF THE EXHAUST HOOD IN THE KITCHEN HAS A CAPACITY IN EXCESS OF 400 CFM, IT MUST BE MECHANICALLY OR NATURALLY PROVIDED WITH MAKEUP AIR AT A RATE OF APPROXIMATELY EQUAL TO THE EXHAUST TO THE EXHAUST AIR RATE, SUCH MAKE UP AIR SYSTEMS MUST BE EQUIPPED WITH NOT LESS THAN ONE DAMPER, EACH DAMPER SHALL BE A GRAVITY DAMPER OR AN ELECTRICALLY OPERATED DAMPER THAT AUTOMATICALLY OPENS WHEN THE EXHAUST SYSTEM OPERATES, 7,WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQ, INCHES SHALL BE PROVIDED IN THE CLOSET ENCLOSURE OR MAKEUP AIR SHALL BE PROVIDED BY OTHER APPROVED MEANS PER SMC 504,6, Vertical Fenestration (Windows and doors) ACTUAL SIZE Component Width Height Sill Description Ref. U-factor Qt. Feet �ncn Feet �ncn Feet inch Area UA D1-SLIDER WSEC 0.30 1 6 ° 6 $ 0 ° 40.0 12.00 Sum of Vertical Fenestration Area and UA 40.0 12.00 Vertical Fenestration Area Weighted U = UA/Area 0.30 WINDOW &DOOR SCHEDULE NOTES; 1, XO = SLIDERS SH =SINGLE HUNG, DH =DOUBLE HUNG, FIX = PICTURE, C =CASEMENT 2, IF CONTRACTOR DECIDES TO REPLACE WINDOWS, THEY MUST MEET ENERGY PERFORMANCE STANDARDS, HEAT TREATMENT REQUIREMENTS AND EGRESS, 3, ALL WINDOWS SHALL BE NFRC CERTIFIED, 4, CONTRACTOR TO VERIFY EGRESS AND HEAT TREATMENT REQUIREMENTS WITH WINDOW &DOOR MANUFACTURER, 5, EGRESS WINDOWS SIZED FOR "MILGARD STYLE LINE" SERIES WINDOWS, CONTRACTOR TO VERIFY EGRESS REQUIREMENTS IF A DIFFERENT MANUFACTURER /MODEL IS CHOSEN, INSULATION CERTIFICATE ISEATTLEI CONTRACTOR SHALL COMPLETE AND POST AN INSULATION CERTIFICATE FOR RESIDENTIAL CONSTRUCTION WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION, AIR LEAKAGE ISEATTLEI: A WRITTEN REPORT OF THE TEST RESULTS, SHALL BE SIGNED BY THE TESTING PARTY AND PROVIDED TO THE BUILDING INSPECTOR, PRIOR TO CALL FOR FINAL INSPECTION, HIGH EFFICACY LAMPS A MINIMUM OF 75 PERCENT OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH -EFFICACY LAMPS, w z 0 w z 0 U W 0 U /' YEN DESIGN INC. 206.432.1111 WWW.YENDES.COM APPROVAL STAMP ENGINEER STAMP J W O w J z w �_ (n w z OC G w O L� X w Q U z O _� J J m 0 N 0 rn � p � Z � O o � 0 � w oZS � W W � O z Q O 0 °� � O J � 0 _ U � � 0 W Z W �ESUB Jun 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOB NO. 20-231 HALF SCALE 11x17 FULL SCALE 22x34 SHEET A1.1 PLAN KEYNOTES 1, PROVIDE �1� 4X4 HF#2 POST, CONTRACTOR TO VERIFY DIRECT LOAD PATH TO EXISTING FOUNDATION BELOW. IF ADEQUATE FOUNDATION IS NOT PRESENT PROVIDE 29'I SQ. X 10'I THICK FOOTING REINF, WITH �2� #4 EACH WAY, SEE 5/A5,1 FOR BALANCE OF INFO. 19'-10 � ° 32'-1 � II LEGEND I I Iz 0 � NEW STUD WALL, SEE 1/A5,1 FOR FRAMING INFO, � w � � 0 EXISTING WALL TO REMAIN o m - — — — - DEMOLISHED NON -BEARING WALLS IU,N,O,I � _o w ■ � � � ■ NEW BEAM/HEADER w w o o a U ■ � � � ■ EXISTING BEAM TO BE REMOVED SD SMOKE DETECTOR LLJ o N N 0 0 ON �-'% THIS SHEET FORK BALA CE OF INFORMATIONEYNOTES � o CD CARBON MONOXIDE DETECTOR WITH BATTERY BACKUP, EF EXHAUST FAN �INTERMITTENT� 50 CFM U,N,O, OSEE DOOR AND WINDOW SCHEDULE ON SHEET A1,1 FOR � DETAILED INFO, SEE 2/A5,1 & 3/A5,1 FOR FRAMING INFO. YEN DESIGN INC. GENERAL NOTES A, PLANS MUST BE APPROVED BY THE GOVERNING BUILDING 206.432.1111 OFFICIAL OR PROFESSIONAL ENGINEER PRIOR TO WORK WWW.YENDES.COM COMMENCING, APPROVAL STAMP B. CONTRACTOR TO VERIFY ALL STRUCTURAL LOAD PATHS AND EXISTING SHEAR /BRACED WALL LOCATIONS BEFORE REMOVING ANY WALLS. STRUCTURAL DEVIATIONS FROM THE PLAN SHOULD BE VERIFIED BY A STRUCTURAL ENGINEER OR BUILDING INSPECTOR, YEN DESIGN IS TO BE CONTACTED IF ACTUAL EXISTING FRAMING CONDITIONS VARY FROM PLAN ASSUMPTIONS AFTER CEILING WALL COVERINGS ARE REMOVED, C. SEE SHEET A1,1 FOR COMMON CODE REQUIREMENTS, D, CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF THE DWELLING AND PLACED IN PROXIMITY TO SLEEPING AREAS, ENGINEER STAMP E, SMOKE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF THE DWELLING AND WITHIN EACH SLEEPING AREA, DIRECT WIRING REQUIRED. F. VERIFY WINDOW &DOOR ROUGH OPENING SIZES WITH WINDOW & DOOR MANUFACTURER. N I I I I I 401 /\ _,� � LN III \ � I I I I =,y G. ALL DIMENSIONS TO STUD WALL, PROPOSED BASEMENT FLOOR PLAN 22x34: SCALE 1/4" = 1'-0" 11x17: SCALE 1/8" = 1'-0" H, CONTRACTOR TO VFY ALL DIMENSIONS ON SITE PRIOR TO CONSTRUCTION, I. CONTRACTOR TO DETERMINE &VERIFY ALL WASTE DIVERSION REQUIREMENTS PER THE LOCAL JURISDICTION. CONTRACTOR MAY BE REQUIRED TO REQUEST LEED REPORTS FROM RECEIVING FACILITIES, J. DOORS WITHOUT PLACEMENT DIMENSIONS WILL BE 3'I OFF WALL OR ON CENTER, AS APPROPRIATE, EXISTING BASEMENT FLOOR PLAN 0' 2' 4' 8' 161 22x34: SCALE 1 /8" = 1'-0" 11 x17: SCALE 1 /16" = 1'-0" � w � x } � z w O ¢ U No � � � rn a � Q � Z � w W °ao 0 w O J Q � � � a � � _ m � � � Z Q J O O J LL z RE�UB Jun'�1�/.�12021 CITY OIGEf/�v10NDS DEVELOPSERVICES DEPA� ENT JOB NO. 20-231 HALF SCALE 11x17 FULL SCALE 22x34 SHEET A2.1 N 0 cV 0 20'-0 �" 32'-0 PROPOSED MAIN FLOOR PLAN 22x34: SCALE 1/4" = 1'-0" 11x17: SCALE 1/8" = 1'-0" PLAN KEYNOTES 2 PROVIDE 18'-11" SPAN 3,511X16,5" 24F-V4 GLU-LAM BEAM PER 4/A5.1 PROVIDE �1� 4X6 DF#2 POST, CONTRACTOR TO VERIFY DIRECT LOAD PATH TO EXISTING FOUNDATION BELOW, IF ADEQUATE FOUNDATION IS NOT PRESENT PROVIDE �9" SQ, X 1311 THICK FOOTING REINF, WITH �3� #4 EACH VAY, SEE 5/A5.1 FOR BALANCE OF INFO, :XISTING BEAM PICKS UP POINT LOAD FROM ABOVE, 'DINT LOAD CONDITION NO LONGER EXISTS, BEAM TO iE REMOVED, :XISTING BEAM TO BE CUT BACK TO 15'-4" SPAN FROM )RIGINAL SPAN OF 26'-7211 'ROVIDE �1� 4X4 HF#2 POST, CONTRACTOR TO VERIFY )IRECT LOAD PATH TO EXISTING FOUNDATION BELOW, F ADEQUATE FOUNDATION IS NOT PRESENT PROVIDE '9" SQ, X 10" THICK FOOTING REINF, WITH j2� #4 EACH VAY, SEE 5/A5.1 FOR BALANCE OF INFO, XISTING LAUNDRY CHUTE TO REMAIN LIVING DINING ►••. LEGEND I I Iz 0 � NEW STUD WALL, SEE 1/A5.1 FOR FRAMING INFO, � w � � 0 EXISTING WALL TO REMAIN o m ----- - — — — - DEMOLISHED NON -BEARING WALLS IU,N,O,I � � � _o ~ w ■ � � � ■ NEW BEAM/HEADER o a o ■ � � � ■ EXISTING BEAM TO BE REMOVED SD SMOKE DETECTOR LLJ o N N 0 0 ON �-'% THIS SHEET FORK BALA CE OF INFORMATIONEYNOTES � o CD CARBON MONOXIDE DETECTOR WITH BATTERY BACKUP, EF EXHAUST FAN �INTERMITTENT� 50 CFM U,N,O, OSEE DOOR AND WINDOW SCHEDULE ON SHEET A1,1 FOR � DETAILED INFO, SEE 2/A5.1 & 3/A5,1 FOR FRAMING INFO, YEN DESIGN INC. GENERAL NOTES A, PLANS MUST BE APPROVED BY THE GOVERNING BUILDING 206.432.1111 OFFICIAL OR PROFESSIONAL ENGINEER PRIOR TO WORK WWW.YENDES.COM COMMENCING, APPROVAL STAMP B, CONTRACTOR TO VERIFY ALL STRUCTURAL LOAD PATHS AND EXISTING SHEAR /BRACED WALL LOCATIONS BEFORE REMOVING ANY WALLS, STRUCTURAL DEVIATIONS FROM THE PLAN SHOULD BE VERIFIED BY A STRUCTURAL ENGINEER OR BUILDING INSPECTOR, YEN DESIGN IS TO BE CONTACTED IF ACTUAL EXISTING FRAMING CONDITIONS VARY FROM PLAN ASSUMPTIONS AFTER CEILING WALL COVERINGS ARE REMOVED, C. SEE SHEET A1,1 FOR COMMON CODE REQUIREMENTS, D, CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF THE DWELLING AND PLACED IN PROXIMITY TO SLEEPING AREAS, ENGINEER STAMP E, SMOKE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF THE DWELLING AND WITHIN EACH SLEEPING AREA, DIRECT WIRING REQUIRED. F, VERIFY WINDOW &DOOR ROUGH OPENING SIZES WITH WINDOW & DOOR MANUFACTURER, G. ALL DIMENSIONS TO STUD WALL, H, CONTRACTOR TO VFY ALL DIMENSIONS ON SITE PRIOR TO CONSTRUCTION, I. CONTRACTOR TO DETERMINE &VERIFY ALL WASTE DIVERSION REQUIREMENTS PER THE LOCAL JURISDICTION. CONTRACTOR MAY BE REQUIRED TO REQUEST LEED REPORTS FROM RECEIVING FACILITIES, J. DOORS WITHOUT PLACEMENT DIMENSIONS WILL BE 3'I OFF WALL OR ON CENTER, AS APPROPRIATE, BEDROOM DN CL CL ' BATH JTCHEN nn �nTu EXISTING MAIN FLOOR PLAN 22x34: SCALE 1 /8" = 1'-0" 11 x17: SCALE 1 /16" = 1'-0" o�nonnnn CLOSET CLOSET nrnn��n n CLOSET � • � � � w � x } � z w O ¢ U No � � � rn a � Q � Z � w W °ao 0 w O J Q � ,� o � a � � _ m � � � Z Q J O O J Z a RE�UB Jun 10 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JOB NO. 20-231 HALF SCALE 11x17 FULL SCALE 22x34 SHEET A2.2 IEI JOIST OR RAFTER 2X BLOCKING w/ �3I 10d EA END UNLESS PERP, FRMG ABOVE Sr11 C t71 A TC ,.. / 13 IEI JOIST — REMOVE FINISHES PER CONTRACTOR RECOMMENDATION \ I3� 10d @ EA BLKG NEW INTERIOR WALL SECTION SCALE: 1 "=1'-0" PERPENDICULAR '>1 T TALL `� 2x JOIST EAM PER PLAN PLATE JOIST OR A A �TFI? /Ti?I ICC w/ GALVINIZED NAILS OR BETTER sr S R N :G ALL 344 COLUMN 4SE SONO TUBE RM TO GRADE OR OVE � #4 VERT, DOWEL INFORCEMENT =R PLAN BRACE HEADER WITH - �1� 16d NAIL TOENAILED TO TOP PLATE ABOVE @ 2411 o,c,l CD C9 � z o z cz W o °- � O OPENING F,F, . SOLE PLATE �RO� ROUGH OPENING TYP. OPENING FRAMING SCALE: 1 /2"=1'-0" CONT DBL TOP PLATE HEADER PER PLAN FLUSH TO EXTERIOR CRIPPLE STUDS TO ALIGN w/ TRIMMERS FULL HEIGHT KING STUD OR POST PER PLAN OPTIONAL 2X TO MATCH WALL TYPE STUD WALL FRAMING 2X TRIMMER (JACK STUD OTY PER HEADER SCHEDULE, FACE NAIL TO KING STUD DOUBLE 2X SILL PLATE CRIPPLE STUDS TO ALIGN w/ STUD WALL FRAMING DOUBLE TOP PLATE R-10 RIGID INSULATION R-21 BATT INSULATION WINDOW SECTION SCALE: 1 "=1'-0" HEADER w z J d w m z o o � � � � �_ � ~ � O w w o a U LLJ N N H N O Q � � co 0 0 wo /, YEN DESIGN INC. 206.432.1111 WWW.YENDES.COM APPROVAL STAMP ia��e�ui:�:�:��r_�► i� BEAM PARALLEL TO WALL � BEAM -JOIST CONNECTION 5 CONCRETE PAD FOOTING J o � X w SCALE:1/2"=1'-0" A5,1 SCALE:1"=1'-0" � w z O Q U o o � � �tS rn Q � � � Z � W W °moo � w O J Q � ,� o � Q � � _ m � � �W VJ J_ Q W 0 J Q U w RE�UB Jun '1r�,2021 CITY OR6BMONDS DEVELOPSERVICES DEP� ENT JOB NO. 20-231 HALF SCALE 11x17 FULL SCALE 22x34 SHEET A5.1