Loading...
APPROVED BLD-BLD2020-1007+Calculations+1.22.2021_2.33.14_AM+2002816RESUS BLD2020-1007 Jan 22 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HNLehtinen En 'neerin 4120 Hoyt Ave. Everett,.WA 98203 (425) 25272373 ............................................... REVIEWED BY CITY OF EDMONDS € BUILDING DEPARTMENT I;y-.� Date_I'OI* Page No.. I of PROJECT NUMBER ��L70 LOCATION CLIENT DESIGN CRITERIA CODE LIVE LOADS FLOOR SNOW WIND SEISMIC DEAD LOADS ROOF y FLOOR SOIL, VAI_:UE BEARING LATERAL. 24628 ;I,a �SICNAL�` 2 CALCULATIONS P - BY " �( /) ---- _ DATE: r STRUCTURAL ONLY JURISDICTION ADDITIONAL STRUCTURAL ENGINEERING REQUIREMENTS OR CHANGES TO PLANS ENGINEER'S SEAL ARE AS Si10WN SHT. IS FOR LATERAL NOTES, SCHEDULES AND DF,TAH: S PF.R SPIT. LOADS ONLY, UNLESS NOTED HNLehtinen En ' neerin 4120 Hoyt Ave. Everett, WA 98203 (425) 252-2373 SC15 N1_I By . Date Page No. of 17�) Dd5TRIBU ASCE. 7-10 per Equivalent Lateral Force 12.8-1 in ASCE 7-10 and equation 12.8-2 in ASCE. 7-10: V = C.',W VV here: _ �, S _ W = effective seismic weight SDs R C = seismic response coefficient ` �� s P I = occupancy importance factor = 1 per ASCE 7-10 Section 11.5.1 and Table 1.5-� R = response modification factor SDS == design spectral response acceleration parameter in the short period range Now, per ASCE 7-10 Table 12.14-1 and equations 12.8-11 and 12.8-12 in ASCE 7-10: R - 2 for ordinary reinforced masonry shear wall foundation R = 6.54 for framed walls with plywood X7z vx C — x x S - C, — Ds V ^ C•S W -n (l lw, hRk ` 7 l r:_, Sl=�7,7 SS= 122.116 Sm5 Fq 5 , -= I) 0 x � 2- -2. 16 = 1, 2-2- SMi= FvS1-= 1,5x �7,17 v,-►5 �DI - SMI 3 x 01715 ` �� b7 c: JDS 3 5MS - � x 112 0,�1 Cs = sos/(�) = 014 F=Lo Isrowr) I, 12 �vwr) F = (, z (3-,:z1:TvP4I HNLehtinen E`n g inee, ring 4120 Hoyt Ave. Everett, H'A 98203 i (425) 252-2373 By Date Page No. of s c' h-t P-ictj D7-i7- r - Go G LIVING - OOM o ;'Mml ' HALL INING •• /c yam® WF—i a—u— , V & sa--- - — o JDL (o � � �o �PSF� MASTER BEDROOM 10 P�F-x Io�x T _ 1:�j HN.Lehtinen BV___ Date Eazintl! --rip _g 4120 Hoyt Ave. Everett, WA 98203 Page No. (4 2 5) 25 2 - 2 3.7 3 If ............. ......... �sl S411 c- CONNECTION DETAILS co HNLehtinen EneaggrW9 4120 Hoyt Ave. - Everett,.WA 98203 (425) 252-2373. A 7� Date Page No. .—I of b x 4 4, ��u - 2 ....... . Zf `777 ell, \x\ HNLehtinen Engineerinv! 4120 HOvt Ave. Everett, WA 98203 (425) 252-2373 1.3v llate Page No. .._�..__ of* pT- LD;: Cic t Go) '>e' s/ -0 +Q x 2-/ L51" cS,Q,,F 4x 10 W--itZ-, P,7 FTC I�Sla 6-1111 2x1,65" � 33'sk �� S � BIZ Strong -Drive' SDWC Truss Screws -he Strong -Drive SDWC Truss Screw is tested in accordance with ICC-ES AC233 (screw) and AC13 wall assembly and roof -to -wall assembly) for uplift and lateral loads between wall plates and vertical vall framing and between the top plate and the roof afters or trusses. Strong -Drive SDWC15450 - is recognized for use in chemically- reated wood as described in the evaluation report. Material: Carbon steel :inish: SDWC15450 — E-Coat"; SDWC15600 — 'lear Zinc Coating (with Orange indicator) Installation: • See General Notes odes: See p.14 for Code Reference Key Chart Strong -Drive" SLWC TRUSS Screw Allowable Roof -to -Wall Connection Loads - DF, SP, SPF, HF — 47>" Strong -Drive SDWC15450 Strong-Drive.11 Minor Thread Allowable Loads (Ita.) Model Diameter Length Length -- -- - — — -- — DF/SP SPF/HF Code No. (in.) (in) (in.) Ref. Uplift Ff __- F2 Uplift Ft ___ F2 SDWC15600 0.152 6 53/4 615 1 130 1 •225 485 115 192 IP5, FL, 1. Loads have been increased for wind and earthquake (CD = 1.6); no further increases allowed. Reduce when other loads govern. 2. Allowable loads are for a Strong -Drive SDWC Truss screw installed per the 'Recommended' or 'Optional' installation instructions. The Strong -Drive SDWC Truss screw is to be installed through a double 2x top plate into a minimum 2x4 truss or rafter. 3. A Strong -Drive SDWC Truss screw may be used in each ply of a 2- or 3-ply rafter or truss. The allowable uplift load for each screw shall be multiplied by 0.90, but may be limited by the capacity of the plate or the connection between the top plate to the framing below. Strong -Drive SDWC Truss screws in multi -ply Typical Roof -to -Wall Con Typical Strong -Drive® SDWC Installation - Truss Aligned with Stud (Offset truss similar) Optional Roof -to -Wall Connection Optional Strong -Drive' SDWC Installation - Truss Offset from Stud 30' max. - assemblies must be spaced a minimum of 1 Ys" o.c. 4. Screws are shown installed on the interior side of the wall. Installations on the exterior side of the wall are acceptable when the rafter or truss overhangs the top plates a minimurn of 31h". 5. For uplift continuous load path, plate -to -stud connections 6. When the screw is loaded simultaneously in more than one direction, the allowable load must be evaluated using the following unity equation: (Design Uplift _ Allowable Uplift) + (Design Ft _ Allowable Ft) + (Design F2 _ Allowable F2) < 1.0. 7. Table loads do not apply to trusses with end -grain bearing. p plate -to -stud and top -plate splice fastened per applicable building -c e. �f �. w Do not install Strong -Drivel= SDWC in hatched area Overhang w. min. !. l 13/4" max. Allowable Installation Range (Truss offset from stud only) 112" minimum edge distance Splice m for full values be in upper or y (with or without lower plate a plate splice) 'a C fC N CL M Offset 1/4" from i top plate splice for full values Min. Edge Distance for; Top Plate Splice /2" minimum edge distance Splice may for full values be in upper or (with or without lower plate a plate splice) 0 Offset %" from —� top plate splice for full values Min. Edge Distance for Top Plate Splice 319 .......... J Option 0 2 CONNECTION DETAILS CD 00 00 CY) LIJ < ILL, < Q C) ui C0 < C) 0 To I OF 1 z If To n .1.1.OM .11- 1 o' Lu CD .2 to IOIM ol I- FOR S­1 TO A -n— OF to' -to' 0 W N 0— m o.. &.—u. -- 7 4' Bt-tEEN RIPPORn 11A. .1 o 4' --F- lo—I z z z 0 uj U) Lu < < A v OF T,A,' r,.. J.- APN. 006466000005011II -J;i SECTION A eet Na 7 Y M— ttt� Sh N m. DECK SECTIONS AND DETAILS DETAILS FOR GUARD CONNECTIONS THAT CAN RESIST A SINGLE CONCENTRATED 1 LOAD OF 20G LBS SECTION B Date: 9/28/2020 DETAILS FOR GUARD 1:49:17 PA CONNECTION Scale: Scale Al 05