Loading...
APPROVED ENG PLN BLD2023-0037+Site_Plan+1.10.2023_2.00.32_PM+3307411Ott PROJECT INFORMATION Owner and address; Ma rth yn Jones 1045 Daley St. Edmonds, WA 98026 Parcel I D : 0043 40440 2 SOO Neighborhood: 160SO01 SE1/4 SEC24 T27N R3E Demo existing deck and install new 537.5 sf composite deck with 36" Guard rail. CODES AND DESIGN LIVE LOADS All methods, materials and workmanship shall conform to the 2018 International Building Code (IBC) as amended and adopted by the local Building Department. Snow load: 25 psf Deck live load: 60 psf _Seismic Criteria: Assumed Soil Site Class D; Seismic Design Category D; Sds = 0.859;1- 1.0 FOUNDATION AND SOIL PRESSURE Presumptive vertical foundation pressure: 1,500 psf. STRUCTURAL REINFORCED CONCRETE Al! concrete shall meet the requirements of AC1-301, "Specifications For Structural Concrete For Buildings." Place concrete per AC1-304 and conform to AC1-306R for cold weather placement and AC1-305R for hot weather placement. Protect all concrete from premature drying, excessive hot or cold temperature. All concrete thicker or deeper than 4 inches shall be vibrated during placement. Use internal mechanical vibrators. Inserts, bolts, boxes, pipes, conduits, and other accessories shall be securely installed and inspected prior to placing concrete. Remove water, debris, wood, and loose concrete from space where concrete is to be placed. fc: 3,000 psi minimum at 28 days, 51/2 sack minimum mix (special inspection is not required) Slump: 5 inches maximum water / cement: 0.47 maximum by weight air entrainment: 5% +/- 1 % 3/4-inch maximum size aggregate Cement: ASTM C150, normal -Type I or ASTM C595, Type IL Coarse and fine aggregate: ASTM C33 Water shall be clean and not detrimental to concrete. Admixtures containing chlorides shall not be used. Do not use calcium chloride, fly ash and related materials. Reinforcing steel shall conform to ASTM A615 Grade 60 new billet stock, deformed steel free of rust, scale or other bond -reducing coatings. Tie bars securely with #16 double annealed wire. EPDXY FOR ANCHORS AND DOWELS Use Simpson SET-XP or Hilti HIT HY-20OR adhesive system. Follow manufacturer's instructions for all installation steps, including, injection tools, mixing nozzles, material handling and storing, substrate drilling and cleaning and adhesive injection. WOOD FRAMING AND LUMBER GRADING Allowable stress required shall be in accordance with standard grading rules of West Coast Lumber No. 16. Moisture content shall be maximum 19%. Wood framing details, not shown otherwise, shall be constructed to the minimum standards ofthe IBC and shall conform to Table 2304.10.1 Fastening Schedule of the IBC. Notations on drawings regarding connectors refer to products by the Simpson Tie Company Catalog C-C-2019. Where preservative treated lumber is cut or drilled after treatment thecut surface shall be field treated with approved preservative by repeated brushingl dipping or soaking until the wood absorbs no more preservative. I mo" 5e�M � L J x 537.5 sf I - - 4Br 13 t to S �1 - T7 C I 4 I � � I I LOT COVERAGE CALCULATIONS Lot area: 10,652 sf Structures House/garage 11738 sf DECK 537.5 sf 1,738 sf/ 10,652 sf = 16% coverage 2,275.5/10,652= 21% coverage Impermeable Surfaces House/garage 1,738 sf Driveway/sidewalk 819 sf Back Patio 103 sf Deck f 537.5 sf 3,151 sf 3,151 sf/ 10,652 sf = 30% coverage Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. ENGINEERING DIVISION ---- -- - DTED 11/31/2022 NO STORMWATER MANAGEMENT SYSTEM REQUIRED AT THIS TIME. IF NEW AND/OR REPLACED IMPERVIOUS SURFACE EQUALS 2000SQFT OR GREATER, A STORMWATER MANAGMEMENT SYSTEM MAY BE REQUIRED PER CITY CODES AND STANDARDS ASIDE \OUT CONS I RUC 1 10N,LLC LIC#: INSIDOC886JR 4031168 TH St. SW Lynnwood., WA 98037 (206) 353-4937 If Li 4= 1 I I St-� e b o n 37 a C &e-CAC . APPROVED BY PLANNING Jan 19 2023 Zone RS-6 Corner Flag _ Setbacks: Required Actual Front no rhangp E Side 5' 10' W Side 5' 17' 15' 26' Rear 25' 11' Height BLD2023-0037 RECEIVED Jan 12 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT