Loading...
FIR2020-0111+Fire_Alarm_Equipment_Specification_Sheets+12.15.2020_11.47.23_AMFIR2020-0111 RECEIVED Dec 15 2020 21267-Edmonds Masonic Temple - FA CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Spec # Manufacturer Section Doc Name Fire AlarmSystemEquipnent Gamewell-FCI GWF-7075, OORA-1000R Gamewell-FCI HPFF8 Gamewell-FCI SWL, P2WL Gamewell-FCI P2RK Gamewell-FCI PC2WL Gamewell-FCI ASD-PL3-IV Gamewell-FCI ATD-L3R-IV Gamewell-FCI MS-7AF Gamewell-FCI AMM-2F Anixter 733919 NW Fire Suppression PHSC-155-EPC Doc # 1 2 3 4 5 6 7 8 9 10 11 Honeywell Analog and Networking Systems ao GWF-7075 Intelligent Fire Alarm Control Panel General The Gamewell-FCI®, GWF-7075 is an Addressable Fire Alarm Control Panel (FACP). The GWF-7075 has a signaling line circuit (SLC) Loop that is used to connect the addressable detectors. The SLC loop is capable of supporting up to 75 detectors and 75 modules using the System Sensor® Velociti® Protocol, and it also offers the built-in support for the SWIFT'' wireless fire alarm devices. The GWF-7075 is equipped with two configurable Notification Appliance Circuits (NACs) that support a maximum output of 2.5A. This panel communicates with the built-in, dual -line digital and IP communicator including an optional cellular communication module. The GWF-7075 fire alarm control panel offers the following powerful features: • detector sensitivity • pre -trouble maintenance alert • day/nightthresholds • calibration trouble alert • drift compensation The GWF-7075 panel supports a variety of devices, including the following accessories: • RA-1000Remote Annunciator • 5880 - LED 1/0 Module • GFPS-6S Intelligent Remote Power Supply • 5824 Serial/Parallel Printer Interface Module (for printing system reports) FEATURES & BENEFITS • Built-in support for up to 75 detectors and 75 modules operating in Velociti" mode • Offers a four line LCD display with40 characters per line • Available in a red or a black cabinet • GWF-7075 can be surface or flush mounted • Contains built-in USB interface used for programming • Includes the programmable date setting for Daylight Saving Time • Uses a J u mpSta rt Auto Programming' feature for easy programming • Reports events to the Central Station by point or by zone • System programmable from the front panel • Provides a built-in dual phone line, digital alarm communicator/ transmitter (DACT), IP or optional cellular technologies • Firmware can be upgraded in the field GWF-7075 • Supports up to four SWIFT'" wireless gateways. Each gateway may include up to 49 wireless devices • Supports Class B (Style 4) and Class A (Style 6 orStyle 7 configuration for SLC, and SBUS • Offers a built-in synchronization for some models, Note: To identify the compatible models, refer to the Compatibility Addendum to Gamewell- FCI Manuals, P/N:9000-0427-L8. Optional Accessories RA-1000: Remote Annunciator The RA-1000 is a remote annunciator used to operate the GWF-7075 Fire Alarm Control Panel (FACP). It connects to the control panel via the RS-485 system bus. The RA-1000 is equipped with five status LEDs which indicate: • Alarm • AC Power Loss • System Silenced • Trouble • Supervisory COMPATIBLE DEVICES For a list of compatible devices, refer to the following documents: • Compatibility Addendum forGamewell-FCI Manuals, P/N:9000-0427-L8 • SWIFT'' Intelligent Wireless Detectors, P/N: 9021-60818 • SWIFT' Intelligent Wireless Modules, P/N: 9021-60819 • SWIFT'" Wireless Gateway, P/N:9021-60824 GFPS-6S:Intelligent Remote Power Supply ORDERING INFORMATION The GFPS-6S intelligent power supply delivers 6A of Notification Appliance Circuit (NAC) power and offers GWF-7075: Intelligent Fire Alarm Control Panel Red built-in synchronization for some appliances Intelligent Fire Alarm 77ontrolane ,Black developed bythefollowing manufacturers. SBUS Accessories • System Sensor® • Faraday'' RA-1000:Remote Annunciator (Black) • Gentex® • AMSECO'" Dimensions: 7.4'Hx9.1'Wx1.5' • Wheelock` 18.3 x 23.1 x 3.8 cm Note: Sync Feature Restriction: Not all devices can use the Sync RA-100DR:Remote Annunciator (Red) Feature. To ensure that the selected device works with the Sync Feature, refertothe CompatibilityAddendum toGamewell-FCI - : n e igen emo e p ower upy Manuals, P/N: 9000-0427-L8. Dimensions: 16'H x 12.25"W 3'D (40.6 x 30.9 x 7.6) cm The GFPS-6S provides its own AC power connection, 5824: Serial/ Parallel Module battery charging circuit, and backup batteryfor use Dimensions: 6"H x 7.75'W x 1.44'D with the GWF-7075 FACP. The output circuits can be (15.0 x 19.4 x 3.6) cm programmed as NACs or as auxiliary power 5880: LED 1/0 Module (configurable for constant, resettable, or door holder Dimensions: 7.75"H x 6"W x 1.94'D (19.4 x 15.0 x 4.8) cm power). 5220: Direct Connect Module Dimensions: 131"H x 6 5"W x 213'D 5824: Serial/ Parallel Module The 5824 is equipped with one parallel and one RS- 232 serial port that allows the GWF-7075 to connectto virtually any standard PC -compatible printer to generate reports on site. 5880: LED 1/0 Module The 5880 provides 40 programmable LED outputs and eight supervised dry contact inputs. These devices offer an effective way to customize remote annunciation. The GWF-7075 supports up to eight 5880 modules to offer maximum flexibility. 5220: Direct Connect Module The 5220 is a direct connect mod ule used to connect a fire alarm control panel (FACP) to a city box or polarity reversal communicator. 2 (3.33 x 16.51 x 5.40)cm Miscellaneous Accessories HFSS: Software Suite. Provides programming, upload/ download and event reporting BB-17F: Remote Battery Box Cabinet. Holds up to two 18 Amp Hour batteries. Dimensions: 16' W x 10' H x 6' D (40.64Wx25.40Hx15.24D)cm GWF-7075 Technical Specifications SYSTEMS STANDARDS For a complete listing of all compliance approvals and PHYSICAL: The GWF-7075 is designed to comply with the certifications, please visit Overall Dimensions: 15.12" H x 12.71' W x 3.33" D following standard' http://www.gamewell- 38.40 H x 32.28 W x 8.46 D cm UL Standard: UL 864 9th Edition fci.com/en-US/ documentation/Pages/ Weight: 25 lbs. NFPA STANDARDS Listings.aspx Color: Red or Black NFPA 13 Sprinkler Gamewell-FCI®, System Environmental Operating Temperature: 321F to 120°F NFPA 15 Water Spray P y Sensor' and Velociti® are (0°C to 49°C) registered trademarks and Humidity: 0 to 930A relative humidity NFPA 16 Foam Water SWIFT ' is a trademark of NFPA 70 Honeywell International, Inc. (non -condensing) NFPA 72 AMSFCO' is a registered ELECTRICAL: Central Station trademark of Kobishi America GWF-7075 Primary AC: 120VAC @ 60 Hz, Remote Signaling Inc. 900mA Total Local Protective Signaling Systems Asco® is a registered Accessory Load: 2.5A @ 27.4 VDC Class A Auxiliary Protected Premises Unit & Water Deluge trademark of Asco Power Power -Limited Releasing Service Technologies Inc. NAC Power: lA per NAC, 25A Total AGENCY LISTINGS AND APPROVALS Farraday- is a trademark of Aux Power: 27.4 VDC Faraday LLC. Form C Trouble &Alarm Relay: 2.5A@ 27.4VDC, These listings and approvals applyto the modules GentaxOis a registered Resistive specified in this document. In some cases, certain trademark ofGentex modules or applications may not be listed by certain Corporation Inc. Standby Current: 165 mA approval agencies, or listing may be in process. Alarm Current: 310 mA Consult factory for latest listing status. Microsoft Windows®. and the Battery Charging Capacity: 7 to 35 AH UL: S1869 Windows Logo® are registered trademarks or trademarks of Battery Size: 7 A/H maximum allowed in the control CSFM: 7165-1703:0500 Microsoft Corporation. panel cabinet. Largercapacity batteries can be housed FDNY:COA-6255 in the BB-17F accessory cabinet. OSHPD (CA) UL® is a registered trademark of Underwriter's Laboratories TEMPERATURE AND HUMIDITY RANGES Approved Releasing Solenoids: Inc. This system meets NFPA requirements for operation at 0 Asco° T8210A107 24 VDC 3 A max. 0 Hz Wheelock' is a trademark of - 49°C/32 -120°F and at a relative humidity 93%± 2% Asco®8210G207 24 VDC 3 A max. 0 Hz Cooper -Wheelock Inc. RH (noncondensing) at 321C4 2°C (90°F ±3°F). ISO 9001 Certification However, the useful life of the system's standby batteries This document is not intended and the electronic components may be adversely affected to be used for installation by extreme temperature ranges and humidity. Therefore, purposes. We try to keep our it is recommended that this system and its peripherals be product information up -to - date and accurate. We cannot installed in an environment with a normal room cover all specific applications temperature of 15 - 271C/60 - 80°F. or anticipate all requirements. All speciflcations are subject to change without notice_ For more information Learn more about Gamewell-FCPs GWF-7075 and other products available by visiting www_GamewelLFCI-corn Honeywell Gamewell-FCI 12 Clintonville Read Northford, CT 06472-1610 203.484.7161 60Honeywell 9021-966 I � I Ol/20 www.hnneywetl.com 92020Honeywe11. into .cionai Inc. HPFF8, HPFFBCM, HPFFBE, HPFFBCME NAC Expander/Power Supply Description The Honeywell HPFF8(E) and HPFFBCM(E) are Notification Appliance Circuit (NAC) Expander Power Supplies designed to extend the power capabilities of existing NACs and provide power for auxiliary devices. The HPFF8 and HPFFBCM con- nects to any 12 or 24V Fire Alarm Control Panel (FACP) or operates stand-alone. They provide regulated and filtered 24VDC power to four NAG's and an auxiliary output. The NAG outputs are rated at 3.0 amps each and the auxiliary output is rated at 2.0 amps (this output is continuously supplied, even in alarm, and there- fore must be taken into account for power supply loading and battery size calculations). The combined output cannot exceed 8.0 amps. The HPFF8 and HPFFBCM provide independent output circuit supervision so in the event of a NAC fault they can notify the attached FACP. In addition they have a trouble memory fea- ture that displays past troubles (by NAC) for rapid diagnostics. Synchronization is built in for five appliance brands. The HPFF8 and HPFFBCM have two fully independent super- vised initiating circuits that can be used for synchronized strobes and coded horns. Their NAG outputs may be config- ured as any of the following: • four Class B (Style Y) • two Class A (Style Z) • two Class B and one Class A • four Class A with the optional HPP31076 Class A adapter These power supplies contain an internal Battery charger capable of charging up to 26.0 amp -hour (AH) batteries. The HPFF8 is mounted in a lockable wall cabinet that can accommodate up to two 18AH batteries. The HPFFBCM is designed to mount in Honeywell's large equipment enclosure (EQBB-D4; order separately). Up to four HPFFBCM supplies can be mounted in a D-sized EQ cabinet. Each HPFFBCM can accommodate two 12AH batteries. One of the most challenging aspects of a retrofit application is locating the existing End -of -Line (EOL) resistor. In these appli- cations that have EOL values other than the 3.9k normally used with the HPFF8, a single resistor matching the existing EOL can be used as a reference for all the outputs. This fea- ture speeds installation and system checkout because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k. NOTE: 4 separate programming resistors for the HPFF8 are pro- vided in the hardware kit shipped with each HPFF8(E) and HPFFBCM(E). They are 3.9K (5 of these are provided, need only i for programming), 2.2K (f each), 4.7K (1 each) and IOK (i each) Features • Listed to UL Standard 864, 9th edition. • Four (4) power limited supervised notification application circuits (NAC's) capable of supplying +24VDC at 3.0 amp maximum each. • NAC output circuits may be configured as any of the follow- ing: — Four Class B (Style Y). Honeywell .M — Two Class B & one Class A. — Two Class A (Style Z). — Four Class A (requires the HPP31076 Class A adapter). - Four field -programmable operational modes: — Pass -through. — Temporal generator. — Sync generator. — Pass -through Filtered. • Temporal coding and sync protocols compatible with the fol- lowing notification appliance brands: — System Sensor. — Faraday. — Amseco. — Cooper -Wheelock. — Gentex. • Protocol pass -through for synchronizing large systems. • Two fully independent supervised input/output control circuits. • Redundant activation operation for survivability. • Supports FACP's Selectable Silence ability. • 2.0 amp auxiliary continuously supplied output. • Eight status LEDs. • Supervised AC input, battery voltage, auxiliary output, char- ger, and earth ground faults. • Trouble indication for supervision of the following: — NAC circuits. — Auxiliary output. — AC input. — Battery charger voltage. — Earth ground faults. • Optional two-hour delay for AC loss. • Separate Trouble and AC Fail Form-C relay contacts. • The Trouble Form-C relay contacts selectable for immediate or a 2 hour delay with AC failure. • 26 AH battery charger capability: - HPFF8(E) supports two 12V 18AH batteries - HPFFBCM(E) supports two 12V 12AH batteries per unit. • NAC Overload protection and indication. • Provision for mounting single or 6 circuit addressable con- trol or relay modules inside the enclosure. (Use mounting kit PN 90475.) Specifications Primary Input Power: 120VAC, 60Hz, 3.6A standard; 240VAC, 50Hz, 1.5A on units with E suffix. Secondary Power: 24 volt operation: two 7-26 AH batteries. Battery Charging Capacity: Up to 26 AH batteries. HPFF8 Cabinet: Holds up to two 18AH batteries. HPFFBCM: Holds up to two 12AH batteries. Total Output Current: 8.0A max. Standby Current: 0.075 A. Auxiliary Power Output: 2.OA under all conditions. NAC Output Ratings: 24VDC fully regulated, 3.OA max per circuit (8.0A total). End -of -Line Resistor Range: 1.9K to 25k ohm, 12 watt. Prod- uct ships with 4 separate programming resistors. They are 3.9K (5 each - only need one for programming), 2.2K (1 each), 4.7K (1 each) and 1OK (1 each) Common Trouble: 2.OA at 30VDC. Relay Fail Relay: 2.OA at 30VDC. Input Control Circuits: compatible with 12 and 24 VDC con- trol panel NACs. Input Control Current (alarm): 5.68 mA @ 12 VDC, 12.28 mA @ 24 VDC. Temperature Rating: 32°F to 1207 (0°C to 499C). Relative Humidity: 10% to 93% non -condensing. Cabinet Dimensions: • HPFF8 Cabinet: 16.65" W x 19.0" H x 5.2° D (42.29 W x 48.26 H 13.23 D cm) • Large equipment enclosure (EQBB-D4): 24" W x 45.9" H x 5.15" D (60.96 W x 116.52 H x 13.1 D cm) Product Line Information HPFF8: 8.0A fire rated power supply. Unit includes red enclo- sure, battery cable and installation instructions. 120VAC160Hz. HPFFBE: 240VAC/50Hz version of HPFF8. HPFFBCM: 8.OA fire rated power supply (chassis mounted). Unit includes mounting hardware, battery cable and instruc- tions for installation in large equipment enclosure. 120VAC/ 60Hz. HPFFBCME: 240VAC150Hz version of HPFFBCM. HPP31076: Class A (Style Z) NAC Adaptor. Increase Class A circuits from 2 to 4. Large Equipment Enclosure: EQ series cabinet for mounting HPFFBCM power supplies consists of a backbox (EQBB-D4) and a locking door (EQDR-D4 or FCI-VDR-D4B). Order sepa- rately. CMF-300-6: Six -circuit supervised addressable control mod- ule activated through FACP programming on a select basis to control power supply activation or output. CMF-300: Supervised addressable control module activated through FACP programming to activate power supply. BAT-12120: Battery, 12 volt, 12.0 AH (two required). BAT-1270: Battery, 12 volt, 7.0 AH (two required). 90474: Mounting kit; required to attach an addressable mod- ule onto the control circuit board (included with supply). Listings and Approvals Listings and approvals below apply to all. In some cases, cer- tain modules may not be listed by certain approval agencies, or listing may be in process. Listed under UL 864 9th Edition. • UL Listed: S24562 - FM Approved • CSFM:7315-1637:0102 • NYFD: COA#6032 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate ait requirements. All specifications are subject to change without notice. System SensorG is a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell 12 Clintonville Road 1(877) HPP-POWR Northford, CT 06472-1610 hpp.techserv@honeywell.com www.honeywellpower.com []H-60541:C1 August 2010 Made in the U.S.A. II S® ® U.S. Registered Trademark V CO2010 Honeywell International Inc. ENLINEAYNNAMAIAIEAENNINL Page2of2 QUALITY SYSTEMS Honeywell SrsrEM SENSOR' Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Updated Modem Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 F I R E • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Strobes and Horn Strobes listed for wall mounting only • Horns listed for wall or ceiling use Agency Listings SIGNALING LISTED nYPFOVEQ S5512 FM approved except 7125-1653A5rW S4011 far ALEPT models 7135-1653'M 3057383,3057072 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AWSB65-M • 2122/201 B - Page 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 N-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync -Circuit`" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12-volt-rated notification appliance circuit Outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lenslreflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 41y16 x 411/15 x 211a-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32�Fto 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 "Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) In put Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7"W x 1.91-D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.25'D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVD5865-05 • 212912018 • Page 2 UL Current Draw Data UL Max. Strobe Current Draw (rnA RMS) 8-175Volts 16-33 Volts Candela DC DC FWR 8-175 Volts 16-33 Volts Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal Range 30 143 63 83 75 NIA 107 136 95 NIA 121 155 110 NIA 148 179 135 NIA 172 209 185 NIA 222 257 High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 8—i7.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non Temporal High 106 166 73 94 139 160 182 211 262 Non Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1KNon-TemporalLow 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3-1KNon-Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data ■:.rTrrr..:orn 5 robe aitprrtiroA 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3A KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9` Coded High 85 90 90 1W 3.1 KHz Coded High 84 89 89 ' Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must be provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly on. AWS865-05 • 2122M18 • Page 3 L-Series Dimensions 1.91" 3.46' 49.5 mm 1.25" 3.57' Im. 80 mm 25" � 32.. (9.1 on) (3.9 cm) 32 mm 0 W o �� p p0 00 0 5.2T ,. a, o�d0u0ppo0p0 5.38' 1339mm '-'-"-1 5.27' Op�0/ Op40p' (13.7 an) O 133.9 mm p00100pOt13o 000t000pt0t0 O 0 A0549-M Aa547-00 A0557-60 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL 4.70" (11.94 cm) 1.91" 4.7, (d.85 cmt 119 mm 32 mm asz� 11229 cm( (499 an) (3.18 mm) 014 In _4L W Zcm)LJ 5.67"G(144 mm tp000p000p0 A0554-01 Strobe, Horn Strobe Horn nosaaw Wall Surface Mount Back Box SBBRL/SBBWL L-Series Ordering Information Wall Horn Strobes Horns* HRL* Horn, Red P2WL 2-Wire, Horn Strobe, White HWL* Horn, White P2 RL 2-Wire, Compact Horn Strobe, Red HGRL* Compact Horn, Red Pi 2-Wire, Comp 2 fils act Horn Strobe, White HGWL* Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain P2RLSP 2-Wire, Horn Strobe, Red, FUEGO P2WLSP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire, Horn Strobe, Red P4WL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBWL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. All -ALERT models have "ALERT' marking on cover. *Horn -only models are listed for wall or ceiling use. SYSTEM3825 Ohio Avenue • St. Charles, IL 60174 0201a systemsensor Phone: BOO-SENSOR2 • Fax: 630-377-6495 PfOdu tspec"ica"ons becttocharge wid�tn°" Visit"nms—mm SENSOR fa casein product in4ormatwn, including the latest versos of this data sheet www.systemsensor.com Avos865-05 - V22f2018 ii SrsrEM SENSOR' Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications Speci Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15175, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from -40°F to 151aF • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SIGNALIN & F M G r r. MEA730a 1653187 (ouldocr strobes) tISTEd 7125-1653188 (ham strobes, S4011 (chimes, ban strobes. horns) APPROVED approved chime strokes) S3593 {outdoor and alert strohes) 3023572 M&4452-0.5-E 7135-1653189 (hams, chimes) SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from --40oF to 151 °F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wali applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync*•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for tire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151 °F (-40°C to fib°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DCIFWRI Operating Voltage Rangez 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6"L x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3" D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"L x 5.1 "W x 2.0" D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. R S, PC, and SC products will operate at 12 V nominal only for 15 and 15175 cd. AVDS01201 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) E3��� 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15175 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Law 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15l75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire 16-33 Volts Horn Strobe, High Candela Range (135-185 cd) 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output ,8-175 candela ratings must be reduced in accordance with 16--33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output (cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 15 Do not use below 32°F 15175 30 75 44 95 70 110 110 115 115 135 135 150 150 177 1177 185 1185 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High 82 82 88 88 93 92 100 100 Temporal 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Low 75 75 81 81 88 84 96 92 Temporal 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. Aws0121)1 SpectrAlert Advance Diagrams Wall -Mount Horn Strobes C� erproof Back Box Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Description P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) Pi Ire Horn Strobe, High cd, Red,Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: ' Add 'i to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-R t Add "-R" to model number for weatherproof replacement device (no back box included), onlyfor use with weatherproof outdoor flush mounting plate, WTP and WTPW "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150. 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM ®hochwga5 3825 Ohio Avenue + St. Charles, [L 60174 P�m��s��f,"ati��,e�t�o"h�,9ew,t"wim Ysits�tems­mm SENSOR Phone: BOO-SENSOR2 + Fax: 630-377-6495 a"e"�°°° `t"� "a°° nvoSSoi zai 01201 3�e� «s° °'u s data �` •liz SrsrEM SENSOR' Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Agency Listings SIGNALING LISTED nYPFOVEQ 55512 FM approved except 7125-1653A5rW 54011 far ALEFT models 7135-1653'M 3057383 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDSBBB-02 - 1210112Q17 - Page 3 L-Series Specifications General L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 1'/2-inch back box, 4-inch octagon back box, or double - gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts_ Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 411/16 x 2 1/8-inch back box. The module shall also control two Style Y (class 6) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F WC to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DCIFWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5' high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVD$868-02 • 1210112017 • Page 2 UL Current Draw Data UL Max. Strobe Current Draw (rnA RMS) UL Max. Morn Current Draw (rnA RMS) 8-17.5 Volts 16-33 Volts 8-175 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal Range 30 153 63 86 75 NIA 111 142 95 NIA 134 164 115 NIA 158 191 150 NIA 189 228 177 NIA 226 264 High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3-1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 UL Max. Current Draw (mA RMS), Ceiling Horn Strobe, Candela Range 3.1 KHz Coded (15-177 cd) High 42 43 54 DC input 8-t7.5 Volts 15cd 30cd 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1KTemporal High 111 164 69 94 147 163 184 229 257 3-1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non -Temporal High I'll 172 fig 94 144 164 202 229 271 3.1 K Non-Tem poral Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non Temporal High 107 135 179 198 223 254 286 Non Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Tem poral High 108 135 179 200 225 255 289 3-1 K Non-Tem poral Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output (dEIA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 AVDS86&02 • 1210112017 • Page 3 L-Series Dimensions 6.83' dim (173 n 2.47' (62.7 rnm) 1.37' (34.6 mm) A0545-00 Ceiling -Mount Horn Strobes -01 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes PC2RL 2-Wire. Horn rt.4rlL 4-vvire, riorn WrOCIR, lien PC4WL 4-Wire, Horn Strobe, White 6 92' rl.m (175. c u 2Z (64 mm) 1 � � o O ® O � O o O Ceiling Surface Mount Back Box A0546-00 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box Ceiling Strobes Si Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 1�1 For a ceiling -listed horn -only device, see AVDS865 "Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications". 0� SYSTEM ®PE 17 charge a 5e 3825 Ohio Avenue • St. Charles, IL 60174 Pm��s f,"ations�eec2T7Se "wee Ye ems "em SENSOR Phone: BOO-SENSOR2 • Fax: 630-377-6495 «` "ensproduct" ° AVUS 68_02"9,J01M17 °'u s data ee` AVOSB6&02 � 1210112017 Honeywell I Addressable Devices QGamewell Velociti° Series 3 Detectors Photoelectric Detectors Description The Gamewell-FCI, Velociti® Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 smoke detectors are intelligentaddressable detectors with point ID capabilitythat enable each detectoraddress to be setwith rotaryaddress switches providing exact device locations. The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI,ASD-PL3 photoelectric detector's re -designed optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment. The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR (DNRW) duct smoke detector housing. The ASD-PTL3 multi - sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 1350F fixed temperature thermal sensing. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number after the detector model. Note: Although the E3 Series® and S3 Series panels support both the Velociti® and CLIP' protocols, the GWF-7075 panel does not support the CLIP protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL® Standard 268 7th Edition • Designed with anew profile to offer modern and improved aesthetics Photoelectric Detector • Contains a built-in • Provides rotary address • Includes dual LEDs for • Offers expanded color functional test switch switches(01-159) 360°visibility options activated by external • Supplies optional relay, magnet isolator, or sounder • Supports a lowstandby bases (standard or Low current frequency) Ordering Information NOTE: "-IV' suffix indicates Ivory color model. NOTE: '-BU suffix indicates Black color model. NOTE: "WH" suffix indicates Bright White color model. ASD-PL3: Photoelectric smoke detector, bright white, Vetociti ASD-PL3R: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, bright white, Velociti ASD-PTL3: Photoelectric smoke detector with thermal Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA10OZ: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single -gang electrical box. For use with B501 and B300-6. sensinq, bri htwhite Velociti CK300: Bright White detector kit (Pack of 10) ASD-PL3-IV : Photoelectric smoke detector, ivory, Velociti/ K300-IR: White, detector color kit for use with MCS-COF CLIP eries Detectors. (Pack of 10) ASD-PL3R-IV: Photoelectric smoke detector, remote test CK300-IV: Ivory, detector color kit. (Pack of 10) capable, for use with DNR(W) duct smoke detectors, ivory, CK300-IR-IV: Ivory, detector color kit for use with Velociti/CLIP MCSCOF Series detectors. (Pack of 10) ASD-PTL3-IV: Photoelectric smoke detector with thermal sensing, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N:9021-60540. Note: "IV" suffix indicates Flashscan and CLIP devices. "WH" suffix Indicates brightwhite B501-WHITE: 4" Flangeless mounting base, brightwhite B501-WHITE-BP:4" Flangeless mounting base bulk pack, brightwhite B501-IV: 4" Flangeless mounting base, ivory B300-6: 6" Flanged mounting base, bright white B300-6-IV: 6" Flanged mounting base, ivory B300-6-BP: 6" Flanged mounting base bulk (Pack of 10) B200SR-WH: Standard sounder base, brightwhite B200SR-IV: Standard sounder base, ivory B2005-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, brightwhite B200SR-LF-IV:Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable lowfrequency sounder base, brightwhite B200S-LF-IV: Intelligent addressable lowfrequency sounder base, ivory 8224RB-WH: Relay base, brightwhite 8224RB-IV: Relay base, ivory 6224BI-WH: Isolator base, brightwhite B224BI-IV: Isolator base, ivory DNR: Intelligent duct detector housing, non -relay DNRW: Intelligent duct detector housing, non -relay, watertight CK300-BL: Black detector kit. (Pack of 10) CK300-IR-BI: Black, detector color kit for use with MCSCOF Series detectors. (Pack of 10) M02-04-01: Detectortest magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/ or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole forXR2B. Shipped with three, 5-foot (1.524,m) sections. Velociti°Series 3 Detectors Technical Specifications SYSTEMS Photoelectric Intelligent Detector. Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.49 cm) installed in B300-6 base 4 inches (10.16 cm) installed in B501 base Shipping Weight: 3.4 oz (96.4 g) Operating Temperature Range: Photo: 321 F to 1221 F (0' C to 50' C) Photo in Duct Applications: -41 F to 1581 F (-20° C to 700 C) Photo with Thermal: 321 F to 1001 F (01 C to 380 C) Operating Humidity Range: 10%to 93% non -condensing Rate -of -Rise Detection: Re5pond5 to greater than 150F/minute or 135OF (8.3° C/minute or 570C Air Velocity Range: 0 to 4,000 ft/min (0 to 1219.2 m/min) Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current (@ 24 VDC): 200 UA (o ne communication every 5 seconds with green LED enabled) Max Alarm Current (max.): 2 mA L 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 For more information Learn more about Gamewetl-KI's Velociti® Series 3 Detectors and other products available by visiting www.GamLwell-FCI.com Honeywell Gamewetl-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com STANDARDS For a complete listing of all compliance approvals and The Velociti® Series 3 Photoelectric Detectors are certifications, please visit: designed to comply with the following standard: http://www.gameweli- UL Standard: UL 268 fci.com/en-US/ documentation/Pages/ AGENCY LISTINGS AND APPROVALS Listings.aspx These listings and approvals apply to the modules E3 Series®,Velociti® and specified in this document. In some cases, certain Gamewell-FCI®are registered modules or applications may not be listed by certain trademarks of Honeywell approval agencies, or listing may be in process. International Inc. Consult factory for latest listing status. UL® is a registered trademark UL:52332 of Underwriter's Labaratories FM: 3023594 I nc. M EA FDNY: COA-219-02-F Vol. VI This document is not intended CSFM: 7272-1703:0501 to be used for installation ISO 9001 Certification purposes. We try to keep our product information up-to- date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifi cations are su bjectto change without notice. 92018 H1T I K 104/2018 Honeywell ©2018 Honeywell International Inc. Honeywell I Addressable Devices QGamewell � � Velociti° Series 3 Detectors Thermal Detectors Description The Gamewell-FCI, Velociti® Series 3 intelligent thermal detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing fortoday's contemporary buildings. The Velociti Series 3 heat detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The thermal detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modem design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. Velociti Series 3 thermal detectors provide cost-effective, intelligent property protection using the following single thermfstor: • ATD-L3 offers 135°F fixed thermal detection. • ATD-L3R offers 135°F fixed and rate -of -rise thermal detection. • ATD-L3N provides fixed high -temperature detection at 190°F. For legacy installations, service detectors are available in the classic ivory colorthat will operate in both Velociti and CLIP protocolfor backwards compatibility. Service models are designated bythe -IV part numberthat appears after the detector model. Note: The E3 Series® and S3 Series panels support both the Velociti® and CLIP' protocols, and the GWF-7075 panel supports only the Velociti® protocol. To obtain a complete fist of panels that are listed to Velociti Series 3 detectors, refer to the Corp patibilityAddend um for Gamewell-FCi Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS Thermai Detector • Complies with LILa268 • Contains a built-in Provides rotaryaddress • Includes dual LEDs Offers expanded color 7th Edition functional test switch switches (01-159) used for 3601 visibility options activated by an • Designed with anew Supplies optional relay, profile to offer modern external magnet isolator, or sounder and improved Supports a low standby bases (standard or low aesthetics current frequency) Ordering Information NOTE: "-IV' suffix indicates Ivory color model. NOTE:'-BL'suffix indicates Black color model. NOTE: 'WH"suffix indicates Bright White color model. ATD-1-3: Thermal heat detector,135°F fixed, bright white, Velociti ATD-L3-IV: Thermal heat detector, 135°Ffixed, ivory, Velociti/CLIP ATD-L3 R: Thermal heat detector,135°F rate of rise, bright ATD-L3R-IV: Thermal heat detector,135°F rate of rise, ivory, Velociti/CLIP ATD-L3H: Thermal heatdetector,190°F high temp, bright white, Velociti ATD-L3H-IV: Thermal heat detector,190°F high temp, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N:9021-60540. B501-White: 4' Flangeless mounting base, bright white B501-White-BP: 4' Flangeless mounting base bulk pack, bright white B501-IV: 4' Flangeless mounting base, ivory B501-BL 4' Flangeless mounting base, B300-6:6' Flanged mounting base, bright white B300-6-IV: 6' Flanged mounting base, ivory B300-6-BP: 6' Flanged mounting base hulk pack B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory 8200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, bright white B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory Ordering Information Accessories 5MB600: Surface Mounting Kit(flanged) TR300: Accessory Flange Ring for B300 6' Base, bright white TR300-IV: Accessory Flange Ring for B300 6' Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single -gang electrical box_ For use with B501 and B300-6_ CK3D0: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kitfor usewith MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCS- COF Series detectors. (Pack of 10) CK300-BL: Black detector kit (Pack of 10) CK300-IR-BI: Black, detector color kit for use with MCS- COF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool Allows the installation and/or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole forXR2B. Shipped with three, 5- foot (1.524,m) sections. Velociti°Series 3 Detectors Technical Specifications SYSTEMS Thermal Intelligent Detector physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.6 cm) installed in B300-6 base 4 inches (10.2 cm) installed in B501 base Shipping Weight: 3.4 oz (95 g) Operating Temperature Range: Thermal 1351 F fixed: -41 F to 1001 F (-20° C to 381 C) Thermal 135' F rate -of -rise: -4° F to 100' F (-20° C to 38' C) Thermal 1901 F rate -of -rise: -41 F to 1351 F (-20° C to 571 C) Operating Humidity Range: 10%to 93% non - condensing Rate -of -Rise Detection:: Responds to greater than 151F/minute or 135°F (8.3° C/minute or 57°C Electrical Specifications Voltage Range::15 to 32 VDC Standby Current (@ 24 VDQ 200 uA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.):: 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.):: 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating:: 0.0063 For more information Learn more about Gamewell-FCJ's Velocitill Series 3 Detectors and other products available byvisiting www.Gamewell-FCl.com Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.hnneywetl.com STANDARDS The Velociti® Series 3 Thermal Detectors are designed to complywith the following standard: ULStandard: UL268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factoryfor latest listing status. U L: S2332 FM: 3023594 M EA-FDNY: 219-02-E Vol. VI CSFM:7270-1703-0502 ISO 9001 Certification 9020-0620 1 G 1 04/2018 92018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit httpWwww.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series*, Velociti® and Gamewell-FCII are registered trademarks and CLIP'° is a trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. Allspecifications aresubjectto change without notice. Honeywell Honeywell QGamewell � � MS-7 Series Addressable Devices Manual Fire Alarm PuLL Stations General The Gamewell-FCI, MS-7 Series manual fire alarm pull stations are available in a wide variety of configurations. The pu It stations comply with the Americans with Disabilities Act(ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All pull stations include a key lock/reset which is keyed alike with the Gamewell-FCI fire alarm control panels and other manual fire alarm pull stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a double action pull station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the pull station causes its assigned address to register at the fire alarm control panel. The door contains an LED which flashes green in normalcondition and lights steady red when the station has been activated.* The station features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASFVelociti® Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog MS-7 Series addressable control panels. Activation of the station causes its assigned address to register atthe control panel. The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated* The station features screwterminals. The Velociti® Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and focuses on the single device. The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • The pull stations (MS- 7LOB) are Listed for outdoor applications • Complies with ADApull force requirements • Offers surface or semi - flush mounting • Shock and vibration resistant • Conventional stations Both single and double suitable for use with action putt stations any UL6 Listed control available panel • Includes a tumbler lock for test and reset keyed alike with analog addressable fire alarm controls *Only the red LED is operative in panels that do not operate in Velociti mode MS-7S Single Action Station The MS-7S single action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station, with the additional feature of including bath English and Spanish instructions molded into the unit. MS-7LR Dual -action Agent Release Station The MS-7LR is designed for usewith the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. Itfeatures a set of single pole contacts and screwterminals used to connect to an initiating circuit. NYC -Plate The NYC -Plate provides the backplate for the manual putt station. (See Figure 11 MS-7LRA Agent Release Station with Abort Figure 1 NYC -Plate The MS-7LRA is designed for use with the Gamewell- FCIfire alarm control panelswithreleasing capabilities Ordering Information and Flex Series releasing systems where system abort MS-7: Double action station capabilities are required. It consists of the following: MS-7AF**: Velociti addressable double action station • An MS-7LR mounted on a plate with an abortswitch MS-7ASF**: Velociti addressable single action station • LED indicators that signal system normal and system activated status MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model SB-1/0 backbox. in retrofit applications, the pull station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior pull stations maybe surface mounted or semi -flush mounted on a standard double -gang, or 4-inch (102 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi -flush mounting. 2 MS-7S: Single action station, wire leads MS-7SP: Double action station, English and Spanish instructions MS-7LR: Agent release station, dual -action MS-7LRA: Agent release station with abort switch, LED indicators, dual- action MS-711_013: Double action station, outdoor use (Includes SB-1/0 - Indoor/outdoor use backbox) SB-I/O: Indoor/outdoor use backbackbox SB-10: Surface backbox BG12TR: Trim ring for semi -flush mount, plastic NY -PLATE: NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. MS-7 Series Technical Specifications SYSTEMS Material: Lexan® Contact Ratings: 0.25 amps. @ 30 VAC/VDC (resistive) Dimensions: 5 5/8" H x 41/4" W x 11/4" D (14 x 10.1 x 3.2 cm) Operating Temperature: (MS-7AF, MS-7ASF): 321 to 1201 F CO" to 491 C) (MS-7LOB): -300 to 1500 F (-350 to 660 C) Relative Humidity: (MS-7AF, MS-7ASF):10 to 930/6 (non -condensing) (MS-7LOB):85o/0±511/opa 861}3.61(301±21C) Alarm Current: _0030 amp.0.007 for LED Supervisory Current: (MS-7AF, MS-7ASF):.00030 amps. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 491C/32 -120°F and at a relative humidity 93o/0± 2o/0 RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals he installed in an environment with a normal room temperature of 15 - 271C/60 - 801F_ For more information Learn more about Gamewell-FCI's MS-7 Series and other products available by visiting www_GamewelLFCI-corn Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.hnneywetl.com STANDARDS The MS-7 Series is designed to comply with the following standard: ULStandard: UL 8649th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factoryfor latest listing status. UL: 52465 FM:3023594 MEA FDNY: 67-02-E Vol. VII CSFM: 7160-1703:0119 7160-1703:0170 7160-1703:0109 ISO 9001 Certification 9020-0616 1 F I 1 U17 92017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit httpJ/www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Velociti® and Gamewell-FCI are registered trademarks of Honeywell International Inc. UP is a registered trademark of Underwriter's Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. Allspecifications aresubjectto change without notice. Honeywell 0� Gamewell FIRE CONTROL INSTRUMENTS by Honeywell Description The Gamewell-FCI Velociti® Series, addressable monitor module AMM-2F is a single Style B, Class B initiating device circuit (IDC) with a 47KW end -of -line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell- FCI addressable series fire alarm control panel. Any initiating device with normally open (N.O.) dry con- tacts may be made addressable when connected to the AMM-2F module. The VelocitiO Series use a communication protocol that substantially increases the speed of communi- cation between the sensors and certain Gamewell- FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM-217 module can be programmed to provide a wide variety of input functions to the Gamewell-FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, ple- num detector, waterflow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possi- ble to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-21F can sup- port a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. Velocifi® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Ire. Velecill-8IIIIIIII Series AMM=2F Addressable Monitor Module AMM-2F Features • Compact size allows easy installation • Class B, Style B, initiating circuit • 40 Ohm line resistance for each initiating device circuit • Connects to any normally open dry contact device Specifications Supervisory Current: .000375 amps Alarm Current: .00060 amps Operating Temperature: 32' to 120' F (0' to 490 C) Relative Humidity: 10 to 93% (non -condensing) End -of -Line Resistance: 47K ohms Dimensions: 13r L x 2.5° W x 0.5" D (3,3 x 6.4 x 1.3 cm) Ordering Information Part Number Description AMM-2F Addressable monitor module, single circuit, Style B, Class B An ISO 9001-2000 Company SIGNALING & FN1 M EA LISTED APPRovn Approved S1949 3023594 227-03-E VOL N 7300-7703:102 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA - Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for [heir use. ®2011 Honeywell international Inc. All rights reserved. www.gamewell-fci.com 9020-0626 Rev. D1 page 1 of 1 0 RECESSED 3/4" & 1" STEEL DOORSWITCH SET= 180/184/8080-T SERIES 90 @ LMLU LIS'ILD ♦ Recessed Magnetic Contact ♦ 12" #22AWG Leads or Screw Terminals ♦ Longer Leads, Zip Cord or Jacketed Cable Upon Request ♦ Built-in E.O.L. Resistors and Diodes Upon Request ♦ Supervisory Loops Upon Request ♦ Switches and Magnets Available Separately ♦ Colors: White, Brown, Gray, Black ♦ 0 Indicates U.L. 10C Fire Rated IOC U�SSIp�o r f ll 180-12 oL 8080-T PART NUMBERS: Closed Loop Open Loop SPDT DPDT Standard Gap Up To 1/2" 3/4" Dia. 180-12> Q 185-12 190-12 195-12 On Steel* 1" Dia. 184-12 189-12 194-12 199-12 3/4" Dia. 8080-T 8585-T 1" Dia. 8484-T 8989-T Wide Gap 3/4"+ 3/4" Dia. 180-12WG> O 185-12WG 190-12WG 195-12WG On Steel* 1" Dia. 184-12WG � 189-12WG 194-12WG 199-12WG 3/4" Dia. 8080 TWG 8585 TWG 1" Dia. 8484TWG 8989 TWG *Gaps will increase substantially for installations other than steel *Gaps up to one inch on steel when paired with MC-180 Door Channel Magnet 7/8" Diameter Also Available. PIN 81-12 and 81-12WG. White or Black only. Please call factory. WARRANTY: Lifetime warranty against workmanship, material and factory defects. TOLL -FREE 1-800-445-5218 TOLL,FREE 1-800-523-1227 GEORGE RISKINDUSTRLES, INC. GR.I. PLAZA (308) 235-4645 KIMBALL, NE 69145 FAX (308) 235-3561 E-MAIL: grisales@megavision.com MADE IN U.S A. WEB SITE: www.grisk.com RECESSED 3/4" & 1" STEELDOOR SWITCH SET INSTALLATION APPLICATIONS: The G.R.I. 180-12 is the industry standard 3/4" diameter recessed steel door switch set with 12" leads. The innovative G.R.I. 8080 T series is a 3/4" diameter recessed switch set designed for residential, commercial and industrial steel doors and frames. The shorter length terminals makes the installation of the set quick and simple. 1.420" .920' 35.O8mm 2335mm 0.740" 0.740' 018.18mm 0 18.80- 7Fr _ 0 8.64m I I k=AI 10 E3.37m L o .70 ��-�-----111 01270mm 40Q' 400" 10.16mm 10.16mm MAGNET SWITCH 960" 243&- CI 25.15mm 1 29.72mm0 t 70' 341^ 8.64 646' Aff 10.t6- t.�nm 8080_T MAGNET 184-12 GRI products meet or exceed these minimum general specifications: AW .990' 25.15m m t_17n" 29.72mm0 1aa 8. Z e .0" JI- 12°LEAOs#22AWG 1.02rnm -' I- SWITCH PART NUMBER LOOP TYPE ELECTRICAL CONFIG. REED FORM MAXIMUM INITIAL CONTACT RESISTANCE (a) MAXIMUM CONTACT RATING (W) MAXIMUM SWITCHING VOLTAGE (VDC) MAXIMUM SWITCHING CURRENT (A) 180-12 Closed N/O A .150 10 200 .400 180-12WG Closed N/O A .150 10 200 .400 184-12 Closed N/O A .150 10 200 .400 184-12WG Closed N/O A 150 10 200 .400 8080 T Closed N/O A .150 10 160 .400 8080 TWG Closed N/O A 150 10 160 .400 8484 T Closed N/O A .150 10 160 .400 8484TWG Closed N/O A .150 10 160 .400 185-12 Open N/C B 140 5 175VDC 250 185-12WG Open N/C B .140 5 175VDC .250 189-12 Open N/C B 140 5 175VDC 250 189-12WG Open N/C B .140 5 175VDC .250 8585 T Open N/C B .140 5 175VDC .250 8585TWG Open N/C B 140 5 175VDC 250 8989 T Open N/C B .140 5 175VDC .250 8989 TWG Open N/C B 140 5 175VDC 250 190-12 Open/Closed SPDT C .140 5 175VDC .250 190-12WG Open/Closed SPDT C .140 5 175VDC .250 194-12 Open/Closed SPDT C 140 5 175VDC 250 194-12WG Open/Closed SPDT C .140 5 175VDC .250 195-12 DPDT X 2 -140 5 175VDC 2 195-12WG DPDT C X 2 .140 5 175VDC .250 MENEM 1 9-1 DPDT CX2 Ar 5 175VDC 5 199-12WG DPDT C X 2 .140 5 175VDC .250 CONTACT YOUR G.R.I. DISTRIBUTOR OR CALL: GEORGERISKINDUSTRIES, INC. TOLL -FREE 1-800-445-5218 GRI. PLAZA TOLL -FREE 1-800-523-1227 KBABALL, NE 69145 (308) 235-W5 FAX (308) 235-3561 BA-90 Rev.. P 8l27/2010 MADE IN us. a. E-MAIL: grisales@megavision.com WEB SITE: www.grisk.com PR7CrOWIREO ii ys0ru Protectowire Linear Heat Detector Features • Line coverage... continuous sensitivity. • Seven alarm temperature ratings. • Withstands severe environmental conditions • Approved for hazardous locations. • Easy to install, test, and splice. • Compatible with other initiation devices on same circuit. • Separate pre -alarm and alarm actuations (Type TRI). SiGNAnN4 C IJL Us LISTED APPROVED Introduction Protectowire Linear Heat Detector is a proprietary cable that detects heat anywhere along its length. The sensor cable is comprised of two steel conductors individually insulated with a heat sensitive polymer. The insulated conductors are twisted together to impose a spring pres- sure between them, then wrapped with a protective tape and finished with an outer jacket suitable for the environment in which the Detector will be installed. Protectowire is a fixed temperature digital sensor and is therefore capa- ble of initiating an alarm once its rated activation temperature is reached. At the rated temperature, the heat sensitive polymer insulation yields to the pressure upon it, permitting the inner conductors to move into contact with each other thereby initiating an alarm signal, This action takes place at the first heated point anywhere along the Detectors length. It does not require that a specific length be heated in order to initiate an alarm nor is system calibration necessary to com- pensate for changes in the installed ambient temperature. Protectowire Linear Heat Detector provides the advantages of line coverage with point sensitivity. An ISO 9001 Registered Company M�•—i Protectowire... the first name in linear heat detection. Conductors Heat sensitive polymer Protective tape Outer covering Approximately 5132" (4mm) diameter Applications • Cable trays • Conveyors • Power distribution apparatus: switchgear, transformers, motor control centers • Dust collectors/baghouses • Cooling towers • Warehouses/rack storage • Mines • Pipelines • Bridges, piers, marine vessels • Refrigerated storage • Tank farms • Aircraft hangars Ideally suited to industrial high risk hazards as well as many types of commercial applications, Protectowire Linear Heat Detector has unique advantages over other types of detectors, especially when difficult installation factors or severe environmental conditions are present. When used with a Protectowire FireSystem Control Panel, the Detector will activate a display, showing the location of an over heat or fire condition anywhere along its length. The Detector also meets intrinsically safe standards and is FM Approved for Class I, II, or III, Div. 1, Applicable Groups A, B, C, D, E, F & G hazardous areas, when the appropriate control panel option is ordered. Protectowire Futures & Benefits • Identifies and displays, at the control panel, the alarm location anywhere along its length when used with the exclusive Protectowire Alarm Point Location Meter. • Sensitivity not effected by changes in ambient temperature or length of cable used on the detection circuit. Compensating adjustments are not required. • Steel inner conductors and select outer jackets, provide resis- tance to mechanical damage. • Simple to install and splice with common tools. Junctions can be made without effecting the integrity of the system. • Compatible with other types of alarm initiating devices on the same circuit such as manual pull stations, thermal heat detec- tors and smoke detectors. • Can be installed in hazardous areas when used with suitably approved Protectowire FireSystem Control Panels. • Full range of temperatures and models available to accommo- date the most demanding applications. • Different temperature detectors may be utilized in the same initiating circuit. • Available on stainless steel messenger wire for installations where mounting is difficult such as large open areas. • Portable test equipment available for easy field service. • Ideally suited for activation of extinguishment equipment, such as deluge or pre -action sprinkler systems. Description The Detector is made in multiple temperature ratings to allow for differences in normal ambient temperature. Guidelines for select- ing the proper detector temperature rating are the same as for auto- matic sprinklers and other heat actuated devices. Refer to the Temperature Rating Chart for proper model selection based upon installation temperature limits. The Detector's product range consists of five distinct types of cable, Each designation identifies a specific outer jacket material which has unique characteristics that have been selected to accommodate the widest range of installation environments. All specifications are subject to change without notice. EPC —Type EPC Protectowire consists of a durable flame retardant vinyl outer jacket. This series is best described as multi -purpose and is well suited to a wide range of both commercial and industrial applica- tions. The outer jacket provides good all-around performance for most installations. It features low moisture absorption, resistance to many common chemicals, and excellent flexibility at low temperatures. EPR — The EPR series contains an extruded flame retardant jacket of polypropylene elastomer with a special LTV stabilizer added to enhance weathering performance. It is intended for a wide range of industrial applications and is characterized by high resiliency, good abrasion resistance, excellent weathering properties, and flexibility over a wide temperature range. TRI — Type TRI Protectowire is a unique dual temperature detector which is capable of initiating separate pre -alarm and alarm signals once each of its rated activation temperatures is reached. The Detector consists of a durable vinyl outer jacket which features low moisture absorption, resistance to many common chemicals, excellent flexibility and flame retardant. For complete information on this product, please refer to Data Sheet 9114. XCR — Type XCR utilizes a high performance fluompolymer jacket. This detector is specifically designed for use in applications where extreme environmental and product performance criteria must be met. In general, the flame retardant, low smoke XCR jacket provides excel- lent abrasion resistance and mechanical properties over a broad range of temperatures. It provides excellent chemical and permeation resistance to a wide variety of acids, bases, and organic solvents as well as simple gases. In addition, the jacket exhibits very little change in tensile prop- erties upon outdoor exposure to sunlight and weather, XLT — Protectowire Type XLT is a unique detector that has been designed for use in cold storage facilities and other applications that require a low alarm activation temperature. The outer jacket consists of a proprietary flame retardant polymer that is specifically formulated to provide low moisture absorption, good chemical resistance, and excel- lent low temperature environmental performance.This detector has been UL and FM tested to - 60'F (-51'C). Installation Protectowire Linear Heat Detector is approved as a heat actuated auto- matic fire detector and is intended to be used on a supervised initiating circuit of an approved fire protective signaling control unit. The Detector must be installed in continuous runs without taps or branches in accordance with applicable sections of NFPA 70 National Electrical Code, NFPA 72 National Fire Alarm Code, or as determined by the local "authority having jurisdiction." Protectowire may be installed at the ceiling level or on the side walls within 20 inches of the ceiling, to protect areas within buildings (area protection). The Detector has the additional benefit of being suitable For installation close to the hazard in order to provide a rapid response (proximity or special application protection), On smooth ceilings, the distance between detector runs shall not exceed the listed spacing. There shall be a detector run within a distance of one-half the listed spacing, measured at a right angle, from all walls, or partitions extending to within the top 15% of the ceiling height as shown in the illustration. The listed spacing shall be used as a guide or starting point in detector installation layout. Reduced spacing is required based upon factors such as ceiling height and construction, physical obstructions, air movement, or the authority having jurisdiction. When Protectowire is used to activate sprinkler systems, special Factory Mutual (FM) spacing guidelines may also be applicable to the specific hazard being protected. It is mandatory that engineering judgment be applied in determining final detector location and spacing. Ceiling of protected area S=Listed spacing. See chart below. In general, the use of Protectowire in any initiating device circuit, is limited to coverage of a specific hazard or area. Copper wire, of an approved type, with a minimum conductor size of 18 AWG, shall be installed from the control panel out to the hazard area where it is then connected to the beginning of the Protectowire portion of the circuit. The Protectowire portion of each initiating circuit shall begin and Ter- minate at each end in an approved zone box or end -of -line zone box. SR-502 Series, Strain Relief Connectors, shall be installed in all zone boxes where Protectowire enters or exits the enclosure, in order to hold the cable securely. Temperature Ratings and Model Numbers (Use Linear Detector of Proper Temperature Rating) Product Type Model Number Alarm Temperature Max. Recommended Ambient Temperature Approvals/Max. Listed Spacing UL/cUL FM EPC PHSC-155-EPC 155'F (68'C) 115-F (46°C) 50 ft. (15.2m) 30 ft. (9.1m) Multi -Purpose/ Commercial & Industrial PHSC-220-EPC 220-F (105-C) 175'F (79'C) NIA 25 ft, (7.6m) Applications PHSC-280-EPC 280- F (138' C) 200-F (93-C) 50 ft. (15.2m) 25 ft, (7.6m) PHSC-356-EPC 356" F (180-C) 221-F (105-C) 50 ft. (15.2m) See Note 1 EPR Good Weathering PHSC-155-EPR 155'F (68'C) 115-F (46°C) 50 ft. (15.2m) 30 fr. (9.1m) Properties & High PHSC-190-EPR 190' F (88'C) 150'F (66'C) 50 ft, (15.2m) 30 ft, (9.1m) Temperature Jacket PHSC-280-EPR 280-F (138-C) 200-F (93'0 50 ft, (15.2m) 25 ft. (7.6m) Performance PHSC-356-EPR 356' F (180' C) 250-F (121-C) 50 ft. (15.2m) See Note 1 TRI Applications PHSC-6893-TRI Pre -alarm: 155'F (68'C) 115-F (46-C) N/A 15 ft, (4.6m) Requiring Pre -alarm Alarm: 200' F (93' C) XCR High Performance! PHSC-155-XCR 155' F (68'C) 115-F (46-C) 50 ft, (15.2m) 30 ft, (9.1m) Industrial Applications PHSC-190-XCR 190'F (88°C) 150'F (66'C) 50 ft. (15.2m) 30 ft, (9,1m) Excellent Abrasion & PHSC-220-XCR 220- F (105- C) 175'F (79' C) NIA 25 ft, (7.6m) Chemical Resistance PHSC-280-XCR 280' F (138' C) 200'F (93'C) 50 ft, (15.2m) 25 ft, (7.6m) PHSC-356-XCR 356° F (180' C) 250-F (121-C) 50 ft. (15.2m) See Note 1 XLT Multi -Purpose/ PHSC-135-XLT 135' F (57'C) 100-F (38-C) 50 ft. (15.2m) 30 ft, (9.1m) Excellent Low Temp. Note 1: FM Approved for special All Protecrowire models can be su ication use only. on Messenger Wire. Add suffix "-M" To above model numbers. Specifications Maximum Voltage Rating: 30 VAC, 42 VDC Resistance 2W Models: .2 ohms/ft. (.656 ohms/m) Resistance TRI-Wire: .3 ohms/ft. (.984 ohms/m) TRI-Wire Conductor Color Code: Pink =155' F; Clear = 200' F; Black T Common Min. Bend Radius: 2.5 inches (6.4cm) Diameter: Nominal 5/32 inch (4mm) Weight: Nominal 8lbs.1500 ft. (3.6 kg/ I52m) Installation Accessories A comprehensive range of mounting and installation accessories are available for the installation of Protectowire Linear Heat Detector. These include several types of clips, straps, drive rings, beam clamps, cable standoffs, connectors and zone boxes. Their proper use assures a neat and reliable installation, Only installation hardware supplied or approved by The Protectowire Company should be used. Messenger wire is also available for any model Detector on special order. It consists of high tensile strength stainless steel wire, which is wound around the Detector at the rate of approximately one turn per foot. It is a carrier or support wire which is designed to simplify the installation of the Detector in areas where mounting is difficult due to the lack of appropriate support structures or mounting surfaces. When using messenger wire to support the Detector, turnbuckles and eye- bolts must be employed at each end of a run to place tension on the support wire. The maximum Detector run length between turnbuckles should not exceed 250 feet (76m) and the wire must also be supported with approved intermediate fasteners at intervals ranging from 15 feet (4.5m) to 50 feet (15m) depending upon the application, Outdoor messenger wire installations present additional challenges due to envi- ronmental factors such as snow loads, ice build-up or wind. Increased detector support must be provided by using additional intermediate fasteners with closer spacing in all outdoor installations. When order- ing messenger wire configurations, add suffix "-M" to the Protectowire model number. All models of Protectowire Linear Heat Detector have the same size conductors and are readily spliced together with common tools, by means of PWS Splicing Sleeves or PWSC Splicing Connectors. These devices are designed for this specific purpose and are the only approved methods of splicing the Detector. System Capabilities Protectowire Linear Heat Detector is a component of a complete fami- ly of systems manufactured by The Protectowire Company a leader in fire detection for over seventy years. Protectowire fire detection systems provide a complete single source solution for meeting any fire defense need, from hazardous area detec- tion to auxiliary equipment shutdown, and automatic extinguishing release. Accessories The Protectowire Company offers an assortment of fasteners and splicing devices to facilitate installation for both standard and special applica- tions. Full details are available upon request. The Protectowire Company, Inc. ■ 40 Grissom Road, Suite 200, Plymouth, MA 02360-7205, U.S.A. ■ p:781-826-3878 ■ t:781-826-2045 web: www.protectowire.com ■ email: pwire@protectowire.com 0 2009 The Pro[ec[owire Co., Inc. SPECIAL HAZARD FIRE DETECTION SYSTEMS DS 6592V--0211 (IQ