APPROVED PLN BLD BLD2020-1160+Site_Plan+12.16.2020_1.58.56_PM+1951026UMN qAr 2020 LIGHTING DESIGNOpp 192663 Edmonds 9727 Edmonds Way Edmonds, WA 0M. all. DRAWING INDEX: - -- � COVER SHEET LU-1 GENERAL NOTES � a LU-2 LUMINAIRE SCHEDULE low — LU-3 OVERALL SITE PLAN C�SI LU-4 FULL SITE PHOTOMETRICS VICINITY MAP LU-5 FIXTURE REMOVAL & DIMENSIONING PLAN LU-6 ATM COMPLIANCE AREA PHOTOMETRICS PLAN - FOR BANK USE ONLY v2 201208 Facility Analysis T Engineering 1629 Smirl Drive, Suite 200, Heath, Texas 75032 www.gmrl.com Office: (972) 771-6038 THIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF WELLS FARGO AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF WELLS FARGO LIGHTING CONTROL NOTES: CONTRACTOR RESPONSIBILITIES: FIXTURE CLARIFICATION NOTES: .. THE CONTRACTOR SHALL VERIFY THE CONTROLS FOR ALL EXTERIOR LIGHTING ON THE SITE (EXCLUDING 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PERMITTING, INCLUDING COORDINATION WITH 1. GMR MAY COMBINE OR ADD TO NOTES AS NEEDED IN ORDER TO CLARIFY FURTHER. SIGNAGE) AND ADJUST ACCORDING TO THE FOLLOWING: THE LOCAL JURISDICTION AND ANY ASSOCIATED PERMIT FEES OR PROCESSING. 2. OUT OF SCOPE - EXISTING FIXTURES TO REMAIN ON SITE WITHOUT MODIFICATION. NO . • PHOTOCELL CONTROL: 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING DOCUMENTS THAT ARE NOT ACTION REQUIRED UNLESS NOTED OTHERWISE. • CONTRACTOR SHALL REPLACE EXISTING PHOTOCELLS WITH NEW AND INSTALL IN A LOCATION BEST INCLUDED IN THE LIGHTING DESIGN PACKAGE. 3. REMOVE AND PATCH - EXISTING FIXTURES TO BE FULLY REMOVED AND ANY PAINTING, SUITED TO PROVIDE APPROPRIATE LIGHT EXPOSURE SUCH THAT EXTERIOR LIGHTS ARE ON ALL HOURS 3. CONTRACTOR IS REQUIRED TO RECYCLE ALL LAMPS AND BALLASTS WHEN SUCH PATCHING OR ELECTRICAL WORK NEEDED IS TO BE ASSESSED AND PERFORMED BY GC. OF DARKNESS. REPLACEMENT IS REQUIRED. 4. REPLACE EXISTING FIXTURE - EXISTING FIXTURE TO BE FULLY REMOVED AND REPLACED IN 4. CONTRACTOR SHALL VERIFY VOLTAGE REQUIREMENTS FOR FIXTURES PRIOR TO THE SAME LOCATION WITH A NEW FIXTURE. GC TO VERIFY IF POLE AND/OR POLE BASE IS • TIME CLOCK CONTROL: PLACEMENT OF FIXTURE ORDERS. SUFFICIENT FOR THE NEW FIXTURES. ANY PAINTING, PATCHING OR ELECTRICAL WORK CONTRACTOR SHALL VERIFY TIME CLOCK IS SET PROPERLY AND LEAVE CIRCUIT ON TIME CLOCK 5. CONTRACTOR TO VERIFY LIGHTING CONTROLS PRIOR TO BEGINNING CONSTRUCTION. SEE NEEDED IS TO BE ASSESSED AND PERFORMED BY GC. CONTROL. LIGHTING CONTROL NOTES. 5. ADD NEW FIXTURE - NEW FIXTURES TO BE ADDED. ANY PAINTING, PATCHING OR ELECTRICAL • MANUAL CONTROL: 6. CONTRACTOR SHALL RECEIVE FORMAL APPROVAL FROM GMR ON ANY FIXTURE WORK NEEDED TO BE ASSESSED AND PERFORMED BY GC. MODIFICATIONS OR VARIATIONS FROM THE LUMINAIRE SCHEDULE. 6. ADD NEW POLE & FIXTURE - A NEW POLE AND FIXTURE TO BE ADDED. GC TO SPECIFY POLE CONTRACTOR SHALL VERIFY THAT NO EXTERIOR LIGHTING IS CONTROLLED MANUALLY. IF ANY 7. CONTRACTOR SHALL VERIFY EXISTING AND PROPOSED FIXTURE MOUNTING CONDITIONS IN TO MATCH EXISTING STYLE AND COLOR AND, IF NOT PROVIDED, POLE BASE DATA FOR NEW EXTERIOR LIGHTING IS ON A MANUALLY CONTROLLED CIRCUIT, CONTRACTOR SHALL ADJUST TO BE FIELD. ANY SPECIAL MOUNTING HARDWARE NEEDED FOR PROPOSED FIXTURES SHALL BE POLE LOCATIONS. GC TO VERIFY IF POLE AND POLE BASE IS SUFFICIENT FOR THE HEIGHT, CONTROLLED BY PHOTOCELL. THE RESPONSIBILITY OF THE CONTRACTOR. LOCATION AND FIXTURE SPECIFIED. • WHERE EXTERIOR LIGHTING IS CONTROLLED BY TIME CLOCK (NOT BMS), REMOVE THE TIME 8. CONTRACTOR SHALL SUPPLY ALL NEW LIGHT POLES. NEW LIGHT POLES SHALL MATCH 7. GMR DOES NOT SPECIFY MOUNTING HARDWARE FOR ANY SPECIFIED FIXTURES. GC IS CLOCK CONNECTION AND ADD PHOTOCELL. EXISTING CONDITIONS ON SITE FOR POLE TYPE AND PAINT COLOR. TO WORK WITH DISTRIBUTOR AND/OR MANUFACTURER ON A CASE BY CASE BASIS TO 9. CONTRACTOR SHALL PERFORM ALL NECESSARY PATCHING OR REPAINTING FOR ADDED, IDENTIFY AND ORDER REQUIRED MOUNTING HARDWARE. • WHERE WE ARE ADDING LIGHTING TO REMOTE ATM'S, LEAVE THE EXISTING TIME CLOCK BUT REMOVED, OR REPLACED FIXTURES. 8. GC TO VERIFY WHETHER EXISTING WIRING LOCATIONS OR THE ADDITION OF WIRING FOR CONTROL ALL NEW FIXTURES WITH PHOTOCELLS. 10. CONTRACTOR SHALL REPAIR ANY DISTURBED AREAS BACK TO EXISTING CONDITION NEW FIXTURE LOCATIONS IS SUFFICIENT FOR THE DESIGNATED FIXTURE LOCATION. INCLUDING PAVED AREAS, LANDSCAPED AREAS, ETC. 9. GC TO SPECIFY POLE COLOR AND TYPE PRIOR TO ORDERING. 11. EXPOSED CONDUIT (ONLY WHERE IT CANNOT BE CONCEALED) SHALL BE PAINTED TO 10. ALL FIXTURES ARE ASSUMED BRONZE IN COLOR UNLESS NOTED OTHERWISE IN THE MATCH THE BACKGROUND SURFACE COLOR. LUMINAIRE SCHEDULE. GC TO CONFIRM PRIOR TO ORDERING. 12. CONTRACTOR SHALL VERIFY AND DOCUMENT COMPLETED WORK DURING NIGHT HOURS. ALL FIXTURES (INCLUDING OUT OF SCOPE FIXTURES) MUST BE FUNCTIONAL DURING NIGHT HOURS PRIOR TO SCHEDULING A FINAL SURVEY WITH GMR. 13. CONTRACTOR SHALL PROVIDE BEFORE AND AFTER NIGHT TIME PHOTOS OF THE SITE. 14. CONTRACTOR SHALL RECEIVE A PUNCHLIST FROM GMR UPON FINAL SURVEY FOR ANY REMAINING ITEMS TO BE COMPLETED. 15. NEW LIGHT FIXTURES IN NEW LOCATIONS ARE TO BE MOUNTED IN THE INSTALL RANGE SET BY GMR ON THE DESIGN DOCUMENTS. • ALL FIXTURES MOUNTED TO COLUMNS OR WALLS LESS THAN 5 FEET WIDE ARE TO BE CENTERED. • ALL FIXTURE COLORS AND STYLE AND LUMEN OUTPUT ARE TO BE AS REQUIRED BY GMR WITH NO SUBSTITUTIONS WITHOUT GMR APPROVAL. ■ CONDUIT AND BOXES ARE TO BE FULLY CONCEALED IN ALL WALLS, SOFFITS AND COLUMNS THAT ARE NOT A PART OF THE BUILDING STRUCTURE OR OF GENERAL NOTES: MASONRY THICKER THAN 6 INCHES. ■ ALL EXPOSED CONDUIT AND BOXES LOCATED IN AREAS WHERE VISIBLE TO THE PUBLIC SHALL BE PAINTED TO MATCH THE COLOR OF ITS SURROUNDING 1. EXISTING CONDITIONS SHOWN ON THE DRAWINGS ARE BASED ON A LIMITED AMOUNT OF SURFACES. INFORMATION AVAILABLE TO THE ENGINEER. ALL SUCH CONDITIONS SHALL BE VERIFIED BY 16. ALL FIXTURE REPLACEMENT FOR EXISTING FIXTURE LOCATIONS SHALL FULLY COVER ALL OF THE CONTRACTOR PRIOR TO SUBMITTING THE BID AND ADJUSTED IF NECESSARY. NO THE MOUNTING SURFACE EXPOSED BY THE REMOVAL OF THE EXISTING FIXTURE, SHOULD ADDITIONAL COMPENSATION SHALL BE GRANTED AFTER AWARDING A BID FOR ANY THE NEW FIXTURE NOT ENTIRELY COVER THE EXPOSED SURFACE THEN A BEAUTY PLATE IS EQUIPMENT, MATERIAL OR LABOR REQUIRED TO REWORK OR OTHERWISE MODIFY EXISTING TO BE INSTALLED BEHIND THE NEW FIXTURE. CONDITIONS. • IF A BEAUTY PLATE IS NOT AN OPTION, THEN THE FIXTURE INSTALLER WILL 2. THIS LIGHTING DESIGN IS BASED ON A COMBINATION OF STATE STANDARDS, THE BANK'S PAINT OR RESURFACE THE EXPOSURE TO MATCH AND TO THE SATISFACTION CURRENT SECURITY POLICY FOR EXTERIOR ATM AND AFTER -HOUR DEPOSITORIES AND BANK OF W.F. OR THE BUILDING MANAGEMENT CO. GUIDELINES FOR NON -SECURITY COMPLIANCE ZONES. 17. ALL REMOVED FIXTURES SHALL HAVE LAMPS AND BALLASTS RECYCLED AS REQUIRED BY 3. TRIM ALL TREES/LANDSCAPING TO MINIMIZE IMPEDING LIGHT FROM ANY LIGHT FIXTURES WF. THAT IMPACT THE 60' RADIUS AROUND ALL ATMS AND A RADIUS OF 50' AROUND ALL 18. ALL DEBRIS CAUSED BY THE REQUIRED SCOPE OF WORK SHALL BE REMOVED FROM THE AFTER-HOUR/NIGHT DEPOSITORIES. CONSIDERATION MUST BE GIVEN TO SITE DAILY AT THE END OF THE WORKDAY. TREES/LANDSCAPING IN A STATE OF FULL FOLIAGE/BLOOM AND FUTURE GROWTH. ALL 19. NO MATERIALS OR EQUIPMENT ARE TO BE STORED ON SITE OVERNIGHT OR WEEKENDS. LANDSCAPING WORK WILL BE PERFORMED BY OTHERS WITH A SEPARATE PERMIT (IF 20. WORK DURING BUSINESS HOURS AND AFTER-HOURS MUST BE APPROVED BY THE PPM. REQUIRED). 21. ACCESS INTO THE BUILDING AND TO ELECTRICAL EQUIPMENT WILL BE AT THE DIRECTION 4. ALL MOUNTING HEIGHTS ARE INTENDED TO THE BOTTOM OF THE FIXTURE. OF THE STORE MANAGER OR PPM. 5. CONTRACTOR TO FIELD VERIFY FIXTURE PLACEMENT DIMENSIONS PRIOR TO CONSTRUCTION. 22. THE INSTALL CONTRACTOR SHALL ABIDE BY ALL FEDERAL, STATE AND/OR LOCAL CODES. IF 6. DIMENSIONING PROVIDED IS FOR PROPOSED FIXTURE LOCATIONS ONLY, UNLESS OTHERWISE A DISCREPANCY BETWEEN CODES OCCURS, THE MOST STRINGENT SHALL PREVAIL. NOTED ON THE DRAWING. 23. ALL CONDUCTORS SHALL BE SIZED ACCORDING TO 2011 NEC OR LATEST VERSION. 7. THE CONTRACTOR SHALL ATTEMPT TO ELIMINATE THE USE OF EXPOSED CONDUIT WHERE 24. ALL NEUTRALS SHALL BE CONSIDERED CURRENT -CARRYING CONDUCTORS ACCORDING TO POSSIBLE. IF EXPOSED CONDUIT IS NECESSARY, THE CONTRACTOR SHALL VERIFY USE WITH 2011 NEC OR LATEST VERSION. PROJECT MANAGER. 8. THE CONTRACTOR SHALL VERIFY THAT LIGHT POLES FOR PROPOSED OR MODIFIED FIXTURES r ARE ADEQUATE FOR THE INTENDED MOUNTING HEIGHT. IF AN EXISTING LIGHT POLE IS BEING V2 201 USED, THE CONTRACTOR SHALL VERIFY THAT IT IS IN SATISFACTORY CONDITION. A TYPICAL POLE BASE DETAIL (AS PER EACH STATE) WILL BE PROVIDED BY GMR FOR EACH SITE. IF A SITE zi� SPECIFIC POLE BASE DETAIL IS REQUIRED, THIS WILL BE COORDINATED BY THE CONTRACTOR zi� AND WILL FOLLOW ANY APPLICABLE STATE OR LOCAL JURISDICTION STANDARDS. 0 REVISEDXX KRM REVISION DESCRIPTION REVISED N0. BY Facility Analysis t Engineering Edmonds SITE ABBREVIATIONS: 9727 Edmonds Way Edmonds, WA PL = PROPERTY LINE 192663 AFG = ABOVE FINISHED GRADE GENERAL NOTES DESIGN BY: DRAWN BY: Fc = FOOTCANDLE ALI DMW REVIEWED BY: APPROVED BY: CBO = CONTROLLED BY OTHERS NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM RMR KRM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED SHEET "IO. AHD = AFTER HOUR DEPOSITORY METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. LU=1 LUMINAIRE SCHEDULE **SEE FIXTURE CLARIFICATION NOTE #9 (NP) = NEW POLE (CBO) CONTROLLED BY OTHERS ** CONTRACTOR TO VERIFY MOUNTING ACCESSORIES BEFORE ORDERING** SYMBOL QTY LABEL FIXTURE ARRANGEMENT TOTAL FIXTURE COUNT NEW POLE COUNT FIXTURE TYPE / MOUNTING / MANUFACTURER BUG RATING MOUNTING HEIGHT MOUNTING ACCESSORIES NOTES 2 A-VK1 DOUBLE (2@180°) 4 - RSX2 LED-P1-40K-R4-MVOLT-RPA-DDBXD / POLE MOUNT/ LITHONIA B2-UO-G2 MATCH EXISTING - REPLACE EXISTING FIXTURE 1 A-VK2 (NEW POLE) SINGLE 1 1 RSX2 LED-P1-40K-R4-MVOLT-RPA-DDBXD / POLE MOUNT / LITHONIA B2-UO-G2 22' AFG - ADD NEW POLE AND FIXTURE 2 A-VL1 SINGLE 2 - RSX2 LED-P2-40K-R4-MVOLT-RPA-DDBXD / POLE MOUNT/ LITHONIA B2-UO-G3 MATCH EXISTING - REPLACE EXISTING FIXTURE 1 A-VT1 (NEW POLE) DOUBLE (2@180°) 2 1 RSX2 LED-P1-40K-R5-MVOLT-RPA-DDBXD / POLE MOUNT / LITHONIA B4-UO-G2 15' AFG - ADD NEW POLE AND FIXTURE 1 A-VW1 (NEW POLE) DOUBLE (2@180°) 2 1 RSX2 LED-P2-40K-R5-MVOLT-RPA-DDBXD / POLE MOUNT/ LITHONIA B5-UO-G3 23' AFG - ADD NEW POLE AND FIXTURE 1 A-VX1 DOUBLE (2@180°) 2 - RSX2 LED-P3-40K-R5-MVOLT-RPA-DDBXD / POLE MOUNT/ LITHONIA B5-UO-G3 MATCH EXISTING - REPLACE EXISTING FIXTURE 6 C-1301 SINGLE 6 - CPY250-A-DM-F-20W-UL-WH-40K/CANOPY MOUNT/CREE B1-U0-G1 MATCH EXISTING XA-BXCC9001 REPLACE EXISTING FIXTURE 25 C-DT1 SINGLE 25 - LR6X-7L-40K / CANOPY MOUNT / CREE B1-U0-G0 MATCH EXISTING GR8 TRIM RING REPLACE EXISTING FIXTURE 1 C-SA1 SINGLE 1 - SEC-EDG-2S-WM-02-E-UL-BZ-350-40K / WALL MOUNT/ CREE B1-U0-G1 8' AFG - ADD NEW FIXTURE 1 C-SJ1 SINGLE 1 - SEC-EDG-4M-WM-02-E-U L-BZ-700-40K / WALL MOUNT/ CREE B1-U0-G1 8' - 6" AFG - ADD NEW FIXTURE 3 YA1 SINGLE 3 - EXISTING POLE FIXTURE - - - OUT OF SCOPE W1 0 L t&A E0, BLUE = NEW FIXTURE GREEN = EXISTING FIXTURE LOCATION TO BE REPLACED ORANGE = EXISTING FIXTURE TO REMAIN TURQUOISE = FIXTURE TO BE REMOVED PINK = REPLACE WITH NEW POLE AT NEW HEIGHT VZ 201208 I /1\ I REVISED XX I KRM I RE IISSIION DESCRIPTION REVISED DESIGN BY: REVIEWED BY: NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED SHEET NO. METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. G R Facility Analysis t Engineering Edmonds 9727 Edmonds Way Edmonds, WA 192663 LUMINAIRE SCHEDULE DRAWN BY: ALI APPROVED BY: RMR DMW KRM LU=2 QTY LABEL NOTES MOUNTING HEIGHT 2 A-VK1 REPLACE EXISTING FIXTURE MATCH EXISTING 1 A-VK2 (NEW POLE) ADD NEW POLE AND FIXTURE 22' AFG 2 A-VL1 REPLACE EXISTING FIXTURE MATCH EXISTING 1 A-VT1 (NEW POLE) ADD NEW POLE AND FIXTURE 15' AFG 1 A-VW1 (NEW POLE) ADD NEW POLE AND FIXTURE 23' AFG 1 A-VX1 REPLACE EXISTING FIXTURE MATCH EXISTING 6 C-1301 REPLACE EXISTING FIXTURE MATCH EXISTING 25 C-DT1 REPLACE EXISTING FIXTURE MATCH EXISTING 1 C-SA1 ADD NEW FIXTURE 8' AFG 1 C-SJ1 ADD NEW FIXTURE 8' - 6" AFG 3 YA1 OUT OF SCOPE - SITE NOTES: EXISTING CONDITIONS: 1• EXISTING POLES - SQUARE - STEEL 2• EXISTING POLE BASES - 2'- 6" 3• EXISTING DRIVE THRU CEILING - HARD BLUE = NEW FIXTURE GREEN = EXISTING FIXTURE LOCATION TO BE REPLACED ORANGE = EXISTING FIXTURE TO REMAIN TURQUOISE = FIXTURE TO BE REMOVED PINK = REPLACE WITH NEW POLE AT NEW HEIGHT ��- = INDICATES NEW SECURITY FENCE PL —= PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATION N.T.S. v2 201208 U REVISED XX KRM REVISION DESCRIPTION REVISED NO. I BY DESIGN BY: REVIEWED BY: �— NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED SHEET No. METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. Facility Analysis t Engineering Edmonds 9727 Edmonds Way Edmonds, WA 192663 OVERALL SITE PLAN DRAWN BY: ALI APPROVED BY: RMR LU=3 DMW KRM CITY LABEL NOTES MOUNTING HEIGHT 2 A-VK1 REPLACE EXISTING FIXTURE MATCH EXISTING 1 A-VK2 (NEW POLE) ADD NEW POLE AND FIXTURE 22' AFG 2 A-VL1 REPLACE EXISTING FIXTURE MATCH EXISTING 1 A-VT1 (NEW POLE) ADD NEW POLE AND FIXTURE 15' AFG 1 A-VW1 (NEW POLE) ADD NEW POLE AND FIXTURE 23' AFG 1 A-VX1 REPLACE EXISTING FIXTURE MATCH EXISTING 6 C-1301 REPLACE EXISTING FIXTURE MATCH EXISTING 25 C-DT1 REPLACE EXISTING FIXTURE MATCH EXISTING 1 C-SA1 ADD NEW FIXTURE 8' AFG 1 C-SJ1 ADD NEW FIXTURE 8' - 6" AFG 3 YA1 OUT OF SCOPE - Q Z 0 W SITE NOTES: dH0 - dHo --- dH0 YA1 MO dHo dHo iHo - dH dH0 dH0 dH0 dH0 dH0 J YA1 �j dH0 dH0 —pI dH0 dHo 6H0 dHo Ho dH0 d"o d"o d"o d"° d"° A-VT1(NEW POLE) A-VL1 FC-DT1 C-D•T1 C-DT1 I o 0 I 11� 0 C-DT1 C-DT1 • C-DT1 I A-VK2 (NEW POLE) I A-VK1 J� C-DT1 C-DT1 o cffl�' o C-B01 dHo dH0 dHo dHo dHo dHo dHo dHo dHo dHo dHo dH0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 PL PL PL — dH0 a0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 C-SA1 C-DT1 C-DT1 C-B01 • C-DT11 A-VL1 777� , 7C-DT1 AHD (1B) • C-DTI ATM (1B) C-SJ 1 C-DT1 • C-DT1 • L— — — — — — — I� A-VW1/(NEW POLE)i J� dHo dHo dH0 dHo dHo dHo dH0 d � PL C-DT1 I C-DT1 4 I I C-DT1 I o� C-DT1 I I I C-DT1 I An dHo dH dH0 dH0 dHo YA1 PL A-VX1 A-VK1 dHo dH0 dHo dH0 dH0 dH0 dHo dHo dH0 dH0 PL - dH0 dH0 dHo dH:_ dHo dHo dHo dH0 dH0 dHo dH0 dHo dHo dHo dHo PL PL PL BLUE = NEW FIXTURE GREEN = EXISTING FIXTURE LOCATION TO BE REPLACED ORANGE = EXISTING FIXTURE TO REMAIN TURQUOISE = FIXTURE TO BE REMOVED PINK = REPLACE WITH NEW POLE AT NEW HEIGHT ---E*—_ = INDICATES NEW SECURITY FENCE PL —= PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATION SCALE: 1" = V-0" 201208 U REVISED XX KRM REVISION DESCRIPTION REVISED NO. I BY G . KAr? Facility Analysis t Engineering Edmonds 9727 Edmonds Way Edmonds, WA 192663 EXISTING CONDITIONS: SITE PLAN ENLARGEMENT DESIGN BY: DRAWN BY: 1• EXISTING POLES -SQUARE -STEEL ALI DMW 2. EXISTING POLE BASES - 2' - 6" �REVIEWED BY: APPROVED BY: — NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM RMR KRM 3. EXISTING DRIVE THRU CEILING - HARD LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED SHEET NO. METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. LU=38 NOTES: 1. THE SCOPE OF WORK FOR THIS PROJECT IS LIMITED TO EXTERIOR LIGHTING RENOVATIONS AS SHOWN ON THE PLANS. 2. REFERENCE THE LUMINAIRE SCHEDULE (SHEET LU-2) FOR ADDITIONAL LIGHT FIXTURE INFORMATION. FULL SITE CALCS Label FULL SITE @ GRADE + + + + + + + + + + + + + + + + + + + + + + + + + 0.4 0.5 0.6 0.7 0.9 1.4 2.0 2.8 3.7 4.2 4.0 3.0 2.4 1.7 1.2 0.9 0.7 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.1 YA1 6H0 dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo d"o d"o dH� dHo+ dHo + dHo dH0 +YA1 + + + + + + + + Q + + + + + + �j d"o + .7d" -0 ° 1d. 1�4 1.9 1.9 2.4 4. 5.3 dHo 2 8 H0 4'i0 dHo dHo dHo dHo �2 dHo �•QHo oa�fb Qkf) dMd•� dH0-�� dHo `�--� dHo � dHo pi dHo dH0 PL PL PL PL - dHo dHo dHo dHo dHo r Ho dHo dHO dH0 dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo + d"o dHo dHo +dHo +Ho + dH + + A-VT1 *UW POL�)2 5.2 4.3 3.4 + 2.0 1 1.6 + 3 1.1 0.9 0.6 0.4 0.3 0.3 0.2 a.7 0 1.3 1.7 2 2.5 3.3 4.2 0.9 13 1.6 2.1 2.7 3.0 3.7 5.6 6.6 6.3 5.0 4.1 3.5 3.1 2.9 2.5 2.1 1.8 .6 1.2 0.8 0.6 0.5 0.4 0.3 FC-DT1 C-DT1 C-DT1 J o o 1.1 1. 2.2 3.1 4.3 4.3 4.6 1 5.9 12.5 6.6 4.5 4.0 3.8 4.0 4.5 4.0 3.0 2.4 2.0 1.5 1.1 0.9 0.7 0.6 0.5 I I 1 C-DT1 C-DT1 + + + + + + + + +o o + + + + + + + + + + + + + + 1.3 2.0 3.0 4.6 6.7 6.0 4.8 13.5 3 9.0 5.6 4.6 5.2 6.6 5.7 4.1 3.1 2.5 1.9 1.5 1.3 1.1 0.9 0.7 1 C-B01 1 I I C-SA1 11, + + + + + + + + + + + + + + + + + 1.1 1.7 .7 4.0 5. A-VL1 4.5 5.8 DTI C-DT1 7. C-130b.1 • C-D1I,19 4.5 5.0A-VL1 4.6 3.9 .1 2.6 2.2 1.9 1.7 1.4 1.2 0.9 K C-DT1 1 • C-DT1 AHD (1B) I C-DT1 •� + 0.5 0.8 1. 1.5 2.0 2.0 1 3 4.13 2.1 2.3 2.2 2.1 2.2 2.2 2.2 2.1 1.9 1 1.4 1.1 I C-DT1 + + + + + + I+ + + + + + + + + + + + + 0.5 0.7 1.1 1.5 2.1 1.9 4. 3.7 .9 2.2 2.2 2.1 2.3 2.6 27 2.7 2.4 2.0 1.7 1.3 C-DT1 I C-DT1 q - + I+ O +1 + 0.6 0.8 1.1 5.5 2. 1.7 2.0 2.2 2.4 2.8 3.4 3,5 3.5 3.1 2.5 1.9 1.5 • C-DT1 I 1 C-DT1 0.5 1.0 .4 2.2 3.0 2.6 1 4. 1 .7 2.0 2.3 2.7 3.4 3.9 3 9 3.8 3.5 2.9 2.1 1.7 1 C-DT1 ° I A-VK2 (NEW -POLE) + C-DT1 + 1 + + + A-VX1+ �� ��"' + + + + + 0.8 1.4 2. 2.7 4.9 4.5 5. 4.13 .9 1.6 1.7 1.8 2.2 4.0 4,1 4.0 3.6 .9 2.1 1.7 I 1 I [C-DT1 ATM (1 B) 1 + + + + + + 1+ + + + + + + + + + + + + 1.3 1.9 2.8 2.5 4.3 8.6 C-DT1 -5.0.5 3.2 3.2 3.4 3 40 3.8 3.5 2. 2.1 1.7 C-SJ 1 C-DT1 1 0 • C-DT1 • L + + + + + -C-B01 C- + - + + + + + + + + + + + 1.3 2.1 3.0 .3 6.4 9.4 16.0 14.3 1 3.9 3.5 3.3 3.4 3.7 37 3.5 3.0 2.3 1.9 1.5 a a a A-VKlEg � O + + + + + Is + + + + + + + + + + + + + + + 1.4 1.9 2.8 4. 4.5 8. l 7.5 5.6 4.5 .9 3.6 4.2 3.8 3.3 3.2 3.1 2 9 2.6 2.3 1.9 1.6 1.3 L A -VW NEW POLE) 1.4 2.2 3.1 4.3 6.2 8.0 4.7 4.7 5.7 4.4 4.0 4.1 5.0 5.0 3.7 3.1 2.7 2.4 2.1 1.8 1.6 .3 1.1 A-VK1 1.3 1.9 2.6 34 4.4 5.3 4.8 4.4 3.9 3.5 3.7 3.9 5.3 6.1 6.1 5.0 3.5 2.7 2.4 2.0 1.7 1.4 1.0 0.8 1.1 1.6 2.0 2.6 3.1 3.6 3.8 3.5 3.6 3.5 3. 3.7 4.6 4.8 3.5 2.6 2.1 1.9 1.5 1.2 0.9 0.7 0.6 J� 0.9 1.2 1.6 2.0 .3 2.6 2.8 2.8 i.9 o d 0dHO d dHo dHo dHo d dH' dH0 d o dHO dHo dHo dH0 dHO aH0 6H0 YA1 + + + + PL+ + PL + + + + PL + + + PL + + + PL + + + + 0.6 0.9 1.1 1.4 1.6 1.8 1.9 9 1.9 1. 1 5-� 1. 1.4 2.0 1.9 1.8 1.5 1.2 1.1 0.9 0.7 0.6 0.4 0.3 0.3 CalcType Units Avg Max Min Avg/Min Max/Min Illuminance Fc 2.67 22.1 0.0 N.A. N.A. + + + + + + + + + + + + + + + + + + + + + + + + + 0.4 0.6 0.7 0.9 1.0 1.2 0.3 0.8 0.5 0.7 1.0 1.1 1.1 1.0 1.1 1.0 1.0 0.9 0.7 0.6 0.5 0.4 0.3 0.2 0.2 + + + + + + + + + + + + + + + + + + + + + + + + 0.3 0.4 0.4 0.5 06 0.7 0.8 0.2 0.0 0.0 0.3 0.4 0.5 0.6 0.8 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 MIN AL KAO, BLUE = NEW FIXTURE GREEN = EXISTING FIXTURE LOCATION TO BE REPLACED ORANGE = EXISTING FIXTURE TO REMAIN TURQUOISE = FIXTURE TO BE REMOVED PINK = REPLACE WITH NEW POLE AT NEW HEIGHT = INDICATES NEW SECURITY FENCE PL = PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATION N.T.S. vz z01 208 U REVISED XX KRM REVISION DESCRIPTION REVISED NO. BY wa im Facility Analysis t Engineering Edmonds 9727 Edmonds Way Edmonds, WA 192663 FULL SITE PHOTOMETRICS PLAN DESIGN BY: DRAWN BY: ALI DMW REVIEWED BY: APPROVED BY: �- NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM RMR KRM LABORATORY DATA UNDER CONTROLLED CONDITIONS N ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED SHEET NO. METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. LU=4 QTY LABEL NOTES MOUNTING HEIGHT 2 A—VK1 REPLACE EXISTING FIXTURE MATCH EXISTING 1 A—VK2 (NEW POLE) ADD NEW POLE AND FIXTURE 22' AFG 2 A—VL1 REPLACE EXISTING FIXTURE MATCH EXISTING 1 A—VT1 (NEW POLE) ADD NEW POLE AND FIXTURE 15' AFG 1 A—VW1 (NEW POLE) ADD NEW POLE AND FIXTURE 23' AFG 1 A—VX1 REPLACE EXISTING FIXTURE MATCH EXISTING 6 C-1301 REPLACE EXISTING FIXTURE MATCH EXISTING 25 C—DT1 REPLACE EXISTING FIXTURE MATCH EXISTING 1 C—SA1 ADD NEW FIXTURE 8' AFG 1 C—Si1 ADD NEW FIXTURE 8' — 6" AFG 3 YA1 OUT OF SCOPE — SITE NOTES: EXISTING CONDITIONS: 1. EXISTING POLES - SQUARE - STEEL 2. EXISTING POLE BASES - 2'- 6" 3. EXISTING DRIVE THRU CEILING - HARD dH0 dH dH0 -- dHo dH0 dH0 dH0 dHo dHo YA1 dHo dHo dHo dH0 dH0 dHo YA1 - dHo .awn PLdHo dHo - dH0 dH0 —p i dHo HO dH0 - d"o dHo d"° A—VT1(NEW POLE) 3-± FC—DT1 C—DT10 C—DW o I C—DTI C-DT1 I C-B01 A—VL1 C—DT1 C—DT1 • C-DT1 I I O C—DT1 C—DT1 dH0 dHo dH0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 dHo dH0 dHo dHo dHo dHo dH0 dH0 dH0 PL PL PL — dH0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 C—DTI • • C—DT1 I A—VK2 (NEW POLE) C-DT1 Ej I I C-DT1 ATM (1 B) 15'-6"± I C—DT1 I C—SJ 1 6DT1 0L 3'± C-11301 C—DTI C-DT1 C—DT1 a a a + +I O A—VK1 N N—I NEW POLE) A—VL1 A—VK1 A—VX1 dH0 dHo dH0 dHo dH0 dH0 dH0 dH0 dHo dHo PL - dH0 dH0 BLUE = NEW FIXTURE GREEN = EXISTING FIXTURE LOCATION TO BE REPLACED ORANGE = EXISTING FIXTURE TO REMAIN TURQUOISE = FIXTURE TO BE REMOVED PINK = REPLACE WITH NEW POLE AT NEW HEIGHT = INDICATES NEW SECURITY FENCE PL = PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATION SCALE: 1 " = 1'-0" dH0 dH0 dH0 dH0 dH0 dHo dHo dHo dH0 dHo dHo dHo dHo dHo dHo dH0 dH0 c- dHo dHo dHo dHo dH0 dH0 dHo dH0 dH0 PL PL YA1 PL PL PL201208 U REVISED XX KRM REVISION DESCRIPTION REVISED NO. I BY DESIGN BY: REVIEWED BY: �— NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS N ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED SHEET NO. METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. G ... KAr? Facility Analysis t Engineering Edmonds 9727 Edmonds Way Edmonds, WA 192663 FIXTURE REMOVAL & DIMENSIONING PLAN DRAWN BY: ALI APPROVED BY: RMR LU=5 DMW KRM h 1 /-%= r f- 1. READINGS ARE MEASURED AT 36" (3') ABOVE GRADE. Q a Z 0 W YA1 dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo dHo dH0 dH0 dH0 Ho d"o dHo J dH0 YA1 dH0 dH dH0 dH0 -�1 dHo dHo dH0 d"o PL _ dHo dHo dHo PL dHo dHo dHo dHo PL dHo dHo dHo dHo PL dHo - dH0 aH0 aH0 dHo dH0 dHo 2.4 --- - + dH0 ai0 dH0 d�H0 id�H0/�\dH0 dH0 dH0 dH0 dH0 dH0 dH0 dH0 . + + + dH0 dH0 dH0 d"° J"° 4 dHo A-VT1(NEW POLE) 4.2 5.0 5.6 5.9 5.2 5.2 5.2 4.9 4.3 3.7 3.4 3.2 + + + + + + + + + + + + -�\\ + + + + + + + + + + + + + + 4.1 4.7 5.7 6.4 5.9 5.6 5.4 5.2 4.7 4.2 3.7 3.4 3.2 3.1 + + + + + + + + + + + + + + + + 3.8 4.8 6.2 7.8 7.4 8.6 6.7 5.6 4.9 4.4 4.0 3.7 3.5 3.3 3.2 3.1 COMPLIANCE AREA FC-DT1 C-DT1 C-DT1 50' RADIUS 3.8 4.3 + 61 + + o + o + �71 5.6 4.6 4.2 4.0 3.8 3.6 3.6 3.6 3.7 + + + 1 + + + + + 1 + + + + + + + + + 4.5 4.8 6.3 6. 11.7 13.6 10.3 7.4 5.8 4.5 4.2 4.0 3.9 3.8 3.9 4.2 4.6 C-DT1 C-DT1 + + + + + + + + + + + + + + + + + + 5.5 5.1 5.4 5.7 1 .7 b 6.4 5.0 4.6 4.4 4.2 4.2 4.4 4.8 5.4 + + + + + + + + + + + + + + + + + + 6.2 5.4 5.0 7.51 1 .6 20.3 5 19.1 14.? 12.4 11.3 9.0 6.4 5.3 4.8 4.8 5.3 6.0 C-B01 5.7 5.3 5.9 7.1 11.9 18.6 19.7 17.3 13.6 15.2 GSA111.7 8.6 6.9 5.7 5.0 5.3 5.7 C-DT1 C-B01 C -DT1 A-VL1 C-DT1 C-DT1 AHD (1) C-DT1 1 C-DT1 I• C-DT1 I • C-DT1 O • C-DT1 I C-DT1 I I • C-DT1 ° I A-VK2 (NEW POLE) C-DT1 I I 1 • C-DT1 ATM (1B) [/\/ L C-SJ 1 "\ C-DT1 C-DT1 1 • C-DT1 • + + + + + + + + + + + + + + + + + + + 5.9 9.2 9.1 12.4 L 22 -24� �0.3- 13 �301�0. C- - 9- .6 - -7 - 3 - 3.9 .7 6.3 5.4 6.4 9.5 1 .0 15.4 12.9 9.9 � 4.9 .4 3.9 3.9 � + + A-VK1O ;+ ++ + + + + + + + + + + + + + 4.7 5.6 7.5 .9 4.0 0.5 7.7 7.3 6.5 5.9 6.0 5.2 4.5 4.1 4.0 3. 4.0 4.1 .7 + + + + + + 6. .7 8.3 J 7 6 5.1 9 6.9 5.4 5.0 4.6 2 3.1 3. 3.8 4.3 + + + + L + +A -VW NEW POLE) + + + i�l+ + + 6.7 6.7 7.2 6.3 8.4 7.7 5.2 5.1 4. N .8 4. 5.1 5. + + + + + + + + + + + + + + + + 7.7 8.4 8.3 6.8 6.1 4.8 4.2 4.4 4.9 4.7 4.4 4.2 4.1 4.3 4. 6.0 + + + + + + + + + + + + 0 6.6 6.7 6.6 6.3 5.4 4.6 4.1 4.1 5.0 4.1 4.0 3.8 4.0 4. + + + + + + + + + + 5.4 5.0 5.0 4.8 3.6 3.8 5.0 4.6 3.8 3.8 4.0 4.1 4.6 �COMPLIANC 4.5 4.2 4.3 4.3 4.2 4.1 4.1 3.5 3.8 + 50' RADIUS + 3%7 3.6 3.5 3.4 + J dH0 dHo J�1 BLUE = NEW FIXTURE GREEN = EXISTING FIXTURE LOCATION TO BE REPLACED ORANGE = EXISTING FIXTURE TO REMAIN TURQUOISE = FIXTURE TO BE REMOVED PINK = REPLACE WITH NEW POLE AT NEW HEIGHT ---E*-_ = INDICATES NEW SECURITY FENCE PL -= PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATION SCALE: 1" = V-0" dH0 dHo aH0 dHo d p dHO dH dH0 aH0 dH0 dHo dHo dHo dH0 dH0 dHo dH0 dHo dHo dHo dH0 PL � PL YA1 dHo 201208'6111\�\ PL PL PL �� ll �L U REVISED XX KRM REVISION DESCRIPTION REVISED NO. I BY G . KAr? Facility Analysis t Engineering Edmonds 9727 Edmonds Way Edmonds, WA 192663 UNIT CALCS 50' ATM COMPLIANCE AREA PHOTOMETRICS PLAN DESIGN BY: DRAWN BY: Label CalcType Units Avg Max Min Avg/Min Max/Min ALI DMW REVIEWED BY: APPROVED BY: NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM RMR KRM AHD 50' @ 36'' Illuminance Fc 6.73 22.5 2.3 2.93 9.78 LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED SHEET N0. METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES ATM1 50' @ 36'' Illuminance Fc 6.35 24.2 2.8 2.27 8.64 MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. LU=6