Eslinger - 631 Elm St_200312_SSSplans_s1904025SHEARWALL SCHEDULE SW EXP Notes apply as called out in table below. 1 Anchor bolts embedded at least 7", or expansion anchors embedded at least 4". See detail SWB. 2 #MASAP can be installed instead of sill bolts with washers. When replacing 1/2"0 sill bolts use 7-10dx1l/2" nails (minimum nailing) and when replacing 5/8"0 sill bolts use 9-10dx11/2" nails (maximum nailing). 4 See detail SWR. Letter designations a & b refer to specific conditions. For gable -end roof connections see detail SWF. 5 See detail SWB. SHEAR FLOW CONNECTIONS / SPACING S, SILL -TO - FLOOR -TO - ROOF -TO - WALL BASE PLATE CALL FOUNDATION 1, 2 SILL &WALL WALL 4 5 OUT 5/8"0 @ 60"oc or *A35 @ *H1 @ 16d @ 10"oc 1/2"0 @ 60"oc 48"oc 3a 24"oc 4a 5/8"0 @ 60"oc or *A35 @ *LS50 @ 16d @ 6"oc 112- 0 @ 40"ocFil 24"oc 36"oc 4b HOLDOWN SCHEDULE Al WALL SHEATHING CALL OUT SHEATHING THICKNESS EDGE NAILS 6 7/16" 10d @ 6"oc 1 Deepen the foundation as needed to provide the required holdown embedment into the foundation wall. See Deatil MHE 2 Fasten to the end framing members of the shearwall, u.n.o. 3 FOUNDATION ANCHOR may be extended with threaded rod and coupler as required. 4 Provide the minimum embedment and edge distances specified by the manufacturer. 5 Attach to (2) 2x studs minimum (lamination connection same as WALL BASE PLATE; stagger nails), u.n.o. 6 See detail HDN for installation. HOLDOWN / STRAP FOUNDATION 1, 2, 4, 6 FASTENERS 5 ANCHOR 1, 3, 4, 6 COMMENTS #STHD14/14RJ 30-16d sinker N/A GENERAL STRUCTURAL NOTES CODE All conditions, materials and construction shall conform to the code specified in the DESIGN CRITERIA, or other codes required by the governing jurisdiction. PROTECTION Through maintenance and current best practices, provide a building envelope that will preserve the integrity of the structure throughout it's lifetime. INSPECTIONS Notify Building Department for inspections required by local jurisdiction. SOILS Bearing capacity of soil shall be per DESIGN CRITERIA or greater. Footing shall bear on solid undisturbed level soil devoid of any organic material and below indicated frost line. COMPACTED FILL shall consist of predominately Well -Graded, granular soil, free of organic material and debris. Fill should be placed in maximum 8" loose lifts and compacted to a minimum of 95 percent of the maximum densityat optimum moisture content determined b ASTM D-1557 test procedures. p Y BACKFILL shall be free draining and without organic material and debris from one of the following soil classes SM-SC, SM, SP, SW, GC, GM, GP, and GW. FOUNDATIONS AND RETAINING WALLS Extend footings to undisturbed bearing soil. Do not backfill until all slabs and/or horizontal diaphragms are constructed, otherwise provide temporary bracing to resist movement. There shall be no machine compaction on the retaining side of the structure for a distance equivalent to 2/3rds the wall height. SILL PLATES Use pressure treated 2x plates u.n.o. Embed anchor bolts at least 7" (expansion anchors 4"). Use 3"x3"x0.229" washers. There shall be a minimum of two bolts per piece spaced not more than 6 feet apart, with one bolt located not more than 12" or less than 4" from each end of each piece. CONCRETE f'c = 3000 psi minimum for environmental exposure (2500 psi used in structural design, or unless greater psi indicated on the plans). 5 1/2 sacks of cement per cubic yard of concrete and a maximum of 6 gallons of water per 94 lb sack of cement. Maximum slump is 4". Segregation of materials shall be prevented through proper handling and placement. REINFORCING STEEL #4 bars and larger shall be Grade 60 deformed bars, and #3 bars shall be Grade 40 (u.n.o.), in accordance with ASTM A-615. Lap splices 32 bar diameters u.n.o. Welded wire fabric shall conform to ASTM A-185 and shall be 6x6 - W1.4xW1.4. Lap one full mesh at splices. CLEAR COVER 3" clr when cast against Earth and 2" clr in all other locations, u.n.o. See applicable detail(s): RI FOOTING DRAINAGE Footing drainage per IBC section 1805.4.2 & IRC section R405.1. WOOD FRAMING in contact with concrete or masonry, or exposed to weather, shall be pressure treated. Numbers in parenthesis, IE (1-1), refer to corresponding engineering calculations. CONNECTORS AND FASTENERS Fasteners, including nuts and washers, and connectors in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. EXCEPTION: Plain carbon steel fasteners, including nuts and washers, in SBX/DOT and zinc borate preservative treated wood in an interior, dry environment shall be permitted. SOLID SAWN LUMBER shall meet the following minimum grades (u.n.o.) conforming to "WWPA GRADING RULES FOR WESTERN LUMBER", latest edition: BEAMS, POSTS, RAFTERS, JOIST 6X and wider DF#1 4X DF#2 2x 10 and greater DF#2 2x 8 and smaller HF#2 WALL STUDS 2x HF#2 TRUSSES Manufactured trusses are a deferred submittal item designed per CODE section 2303.4 and shall be designed for all loads and load combinations per the CODE. All connections per manufacturer, u.n.o. If truss layout is changed by manufacturer, please notify this office. See applicable detail(s): GEB OVER -FRAMING Unless noted otherwise by truss manufacturer, overframe with 2x4 rafters @ 24" oc. Post down w/ 2x4 @ 48" oc, staggered. Brace posts over 6'-0" tall perpendicular to wide face. WALL FRAMING & BEARING Walls shall be 2x studs at 16"oc max with double 2x top plate, and 2x base plate (exterior walls shall be 2x6 u.n.o. & interior walls shall be 2x4 u.n.o.). Party walls shall be parallel walls with a 1" gap between. Each wall shall be framed with 2x4 studs at 16"oc max with double 2x top plate, and 2x base plate. Block all supports solid to the foundation. See applicable detail(s): BHS TPS Full cavity blocks shall be required where party walls intersect exterior walls. BEAM PENETRATIONS Allowable beam penetrations shall be made in the middle third of the span and the middle third of the depth. Contact this office for any penetration outside the allowable area. See applicable detail(s): BP POF GENERAL STRUCTURAL NOTES continued WOOD STRUCTURAL PANELS shall meet the performance standards of the "APA" DOC PS1 and PS2 for their intended application (group 5 species not allowed). SHEARWALLS are indicated on the plans with a bold dashed line and labeled SW. The following letter designation refers to the Shearwall Schedule's SHEAR FLOW CONNECTIONS / SPACING table, and the number designation refers to the WALL SHEATHING table. Multiple combinations of letter and number designations may be present. Wall Line numbers, shown inside triangles, refer to corresponding engineering calculations. Attach rated sheathing (indicated below) to 2x min STUDS spaced no more than 16"oc, u.n.o. See Shearwall Schedule for minimum thickness and fasteners (thickness at point of fastened edges governs shear values). All panel edges shall be blocked. Nail intermediate supports @ 12"oc. Do not penetrate nails past flush. Install squash blocks under the ends of all shearwalls where the framing below does not provide full bearing. Construct cripple walls same as the shearwall above, and gable -ends same as the shearwall below. Rated sheathing: 7/16" OSB rated with a 24/16 span rating. 1/2" CD with a 32/16 span rating. See applicable detail(s): SWE ROOF DIAPHRAGM Install either OSB or CD sheathing: 7/16" OSB rated sheathing with a 24/16 span rating; panel clips required when spacing is greater than 20" oc. 1/2" CD rated sheathing with a 32/16 span rating. Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Nail all boundaries and supported edges with 8d @ 6"oc and interior supports with 8d @ 12"oc, blocking not required u.n.o. ROOF -TOP DECK DIAPHRAGM Install minimum 23/32" rated Sturd-I-Floor T&G with a 24oc span rating Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior supports with 10d @ 12" oc, blocking not required u.n.o. FLOOR DIAPHRAGM Install minimum 23/32" rated Sturd-I-Floor T&G with a 24oc span rating. Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior supports with 10d @ 12" oc, blocking not required u.n.o. COLLECTORS Diaphragms shall be nailed continuously to drag struts, drag trusses and other collector elements at boundary spacing, u.n.o. See applicable detail(s): DTC CS CONNECTIONS and fasteners shall be per CODE Table 2304.10.1 u.n.o. The symbol, "#", indicates a hardware connector from the most current Simpson Strong -Tie Catalog. Hardware with equivilent or greater capacities from other manufacturers may be substituted, example you can use USP's Dual Specification Chart to make an equivilent or greater capacity selection. Install per the manufacturer instructions. Fasteners and hardware in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. NAILS All nails shall be "Standard Common" size per the latest edition of the National Design Specification for Wood Construction (NDS) u.n.o. HOLDOWNS See the HOLDOWN SCHEDULE. See applicable detail(s): HDN HOC POST CAPS Provide a post cap on isolated columns that most nearly matches the actual member size(s) U.N.O. Each connection shall have a minimum of (3)10d to the post and (3)10d to the beam. HANGERS Model numbers will be specified on the plans for conditions that require more than minimum capacity, otherwise see CONNECTIONS. When a hanger is not specified on the plans, use any size specific model number that fits that member. Always use MAX NAILING. Hanger to match member size. Notching or shimming of beam not allowed unless specified. JOBSITE SAFETY Sound Structural Solutions Inc has not been retained or compensated to provide design and/or construction review services related to the contractor's safety precautions or to means, methods, techniques, sequences or procedures for the contractor to perform their work. The undertaking of periodic site visits by the ENGINEER shall not be construed as supervision of actual construction and not make him responsible for providing a safe place for the performance of work by the contractor, subcontractors, suppliers or their employees, or for access, visits, use work, travel, or occupancy by any person. OWNERSHIP OF DOCUMENTS These drawings and calculations are the intellectual property of Sound Structural Solutions Inc. These drawings may not be used in whole or in part by any person without permission of Sound Structural Solutions Inc. MISCELLANEOUS The contractor shall verify dimensions and conditions at job site. The contractor shall provide temporary bracing as required until all permanent connections and stiffenings have been installed. Do not scale drawings. Pre -fabricated items to be handled and installed per manufacturer's recommendations. PLAN INSTRUCTIONS READ THIS FIRST These plans are organized so that more detailed or specific information is found in the same way by following the direction shown below: GENERAL STRUCTURAL NOTES SCHEDULES, DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES for more specific information. SCHEDULES DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES and SCHEDULES for more specific information. DETAILS PLANS will often refer to GENERAL STRUCTURAL NOTES, SCHEDULES and DETAILS for more specific information. PLANS See the SYMBOL LEGEND as well as ABREVIATIONS AND ACRONYMS for other additional information used on the PLANS. The term, TYPICAL (or TYP), used with a detail callout or plan note, indicates that the information specified shall apply in all similar conditions. IF YOU HA VEA NY QUESTIONS OR CONCERNS CON TA CT US IMMEDIA TEL Y! We can be reached immediately by phone: (425) 778-1023 For less pressing questions, email us: inbox@ssseng.com Please help us get to your plans by having this job number handy: s1904025 ABBREVIATIONS AND ACRONYMS ABV ABOVE E.S. EACH SIDE O.C. ON CENTER A. B. ANCHOR BOLT E.W. EACH WAY P.T. PRESSURE TREATED BLW BELOW EA EACH REINF REINFORCEMENT BLK BLOCK E.N. EDGE NAILING REQD REQUIRED BLKG BLOCKING EMBED EMBEDMENT SCHED SCHEDULE B.N. BOUNDARY NAILING EXIST EXISTING SIM SIMILAR BTM BOTTOM FDN FOUNDATION STD STANDARD BRG BEARING FLR FLOOR STRUCT STRUCTURAL BTWN BETWEEN FRMG FRAMING SW SHEARWALL CLR CLEAR FTG FOOTING THRU THROUGH CLTR COLLECTOR G.T. GIRDER TRUSS TYP TYPICAL CONC CONCRETE GR GRADE U.N.O. UNLESS NOTED CONN CONNECTION HORIZ HORIZONTAL # OTHERWISE CONT CONTINUOUS MAX MAXIMUM VERT VERTICAL CTR CENTER MFG MANUFACTURED w/ WITH DBL DOUBLE MIN MINIMUM w/o WITHOUT DET DETAIL o/ OVER W.W.F. WELDED WIRE FABRIC E.E. EACH END oc ON CENTER DESIGN CRITERIA Governing Code 15 IBC Risk Category H Wind Design Data Basic Wind Speed (3 sec gust) mph 110 Surface Roughness B Wind Exposure Category B Earthquake Design Data Seismic Importance Factor, Ie 1.00 Site Classification D Short Period Acceleration, SS 1.264 1-Second Acceleration, S1 0.495 Seismic Design Category D Spectral Response Coefficient, Sps 0.843 Spectral Response Coefficient, Spl 0.497 Gravity Load Data Internal Pressure Coefficient +/- 0.18 Topographic Factor, Kt 1.00 Wind Importance Factor, I 1.00 Seismic Force Resisting System Table 12.2-1: A-13 Response Modification Factor, R 6.5 6.5 Transverse Longitudinal 2010 Equiv. Lateral Force Procedure Seismic Response Coefficient, C, 0.130 0.130 Transverse Longitudinal Seismic Base Shear, V 1316 Ibs Roofs: loads are psf Dead Live Snow •Solar-Ready3 Pitches < 8:12 Top Chord 15 0 25 Bottom Chord 5 0 0 Roors: loads are psf Dead Live Snow Joists5 12 40 0 Notes apply as called out in table above. 3 Dead load includes 5psf for photovoltaic panels. 5 Joists of sawn lumber or wood I -joists. Soil Data Allowable Soil Bearing 12000 psf SSS Number: s1904025 Project Name: Eslinger - 631 Elm St Owner: Mike & Colleen Eslinger Project Location: 631 Elm Street Edmonds, WA 98020 Design Professional: Michel Design M ZO V1 O H 0 J O LU Ln Lr) N J � � Z H O Ln 07 p Z Ui Z O U Cn C 07 Ln V) O DV ti � z 'p 40421, 4 �,�ck— �j fiG is r ¢� SIONAL EN This space reserved for governing jurisdiction stamps ORIGIN DATE: 5/6/2019 REVISED: 3/12/2020 S U EXISTING SHIPLAP SHEARWALL PER PLAN EDGE NAILS PER SW SCHED 2x10 BLKG HANGER , B/W STUDS RAFTER 2x LEDGER w/ (3) % x 8" SOS SCREWS PER STUD (16" oc MAX) FDN DFF P.T. 2x SILL PLATE ROOF LEDGER SUPPORTED BY WALL LRW LOW ROOF TO WALL N.T.S. LRWC #LSTA24 OR #CS16 w/ MIN (9) -10d DIAPHRAGM FASTENERS PER MEMBER U. N.O. COLLECTOR V COLLECTOR BEAM OPTIONAL STRAr LOCATION CS COLLECTOR SPLICE N.T.S. CSAB BOUNDARY NAIL ALONG LENGTH OF COLLECTOR COLL BOUNDARY NAIL ALONG LENGTH OF DIAPHRAGM PER STRUCT NOTES INTERMEDIATE FRAMING ABUTTING PANEL EDGES DTC DIAPHRAGM TO COLLECTOR N.T.S. DTCA EXTENT OF HEADER DOUBLE PORTAL FRAME • . HEADER • [MIN 3"x 11.25" NET] TOP PLATE TO HEADER w/ (2) ROWS 16d SINKERS @ 3"oc #LSTA24 STRAP OPPOSITE SHEATHING M[SHEATHING FILLER IF NEEDED] FASTEN SHEATHING TO HEADER WITH 8d FOR A PANEL SPLICE COMMON OR GALVANIZED BOX IN 3" GRID [IF NEEDED], PANEL 2'-011 PATTERN AS SHOWN AND 3"oc IN ALL EDGES SHALL BE MAX FRMG [STUDS BLKG, AND SILLS], TYP BLOCKED, AND OCCUR WITHIN 24" OF MID- FRMG [MIN (2) 2x4], TYP HEIGHT. ONE ROW OF TYP SHEATHING-TO- FRMG NAILING IS REQD. 8" MIN THICKNESS WOOD STRUCT IF 2x4 BLKG IS PANEL SHEATHING USED, THE 2x4's MUST #STHD14 EMBED FDN STRAP BE NAILED TOGETHER INSTALLED PER MANUFACTURER, TYP WITH (3)16d SINKERS %" 0 A.B. THRU (3) 2x4 MIN PLATES AND EMBED 7" MIN IN FOUNDATION w/ MIN 2"x 2"x %6' PLATE WASHER Y2" MIN FDN PER DET "PFF" TYP PORTAL FRAME WITH HOLD-DOWNS N.T.S. BOTTOM PLATE FLOOR SHEATHING #PSPN58 PLUMBING FLOOR #PSPN516 _L7 DBL TOP PLATE #PSPN516 w/ 8-16d NAILS II TOP PLATE, E, — PLUMBING #PSPN58 w/ 1-8d NAIL INTO BASE PLATE, E,S. NOTCH AS 7 REQUIRED WALL STUD, TYP WALL STUD, TYP TOP PLATE NOTCH BOTTOM PLATE NOTCH PLAN VIEW PLAN VIEW PENETRATION OF FRAMING - EXTERIOR WALL N.T.S. ""1 & #CS16 6)10d 10WN Q STUDS REQUIRED STUDS BEAM 2x4 WALL 2x6 WALL 4x & 2-2x (SAWN) 3%x (GLB) (2) 2x4 (2) 2x6 3%x(MANF) 6x & 3-2x (SAWN) 5%x (GLB) (3) 2x4 (3) 2x6 5%x(MANF) 8x (SAWN) 6%x (GLB) (4) 2x4 (4) 2x6 7x (MANF) GIRDER TRUSS (3) 2x4 (3) 2x6 REQUIRED TRIMMERS HEADER 2x4 WALL 2x6 WALL 4x & 2-2x (SAWN) 3%x (GLB) 2x4 2x6 3%x(MANF) 6x & 3-2x (SAWN) 5%x (GLB) ---- (2) 2x6 5%x(MANF) REQD TRIMMERS NOTE: BEAR BEAMS ON THE FULL WIDTH AND BREADTH OF THE MINIMUM SUPPORTS PER TABLES ABOVE UNLESS NOTED OTHERWISE ON THE PLANS BHS BEAM & HEADER SUPPORTS N.T.S. (8)16d EVENLY SPACED, TYP U.N.O. 16d @ 16" oc TYP FACE NAILS MIN 2x 4N SPLICE TOP PLATE SPLICE DOUBLE TOP PLATE SPLICE N.T.S. DISCONTINUOUS DBL TOP PLATE POST BEAM #CS16 w/, (13) 8d NAILS EA END DISCONTINUOUS DBL TOP PLATE TPSA FOR PSL & LSL, HOLES MUST BE ROUND AND ARE LIMITED TO 2" DIA, UNLESS APPROVED BY THE ENGINEER DO NOT MAKE PENETRATIONS OR NOTCHES MINIMUM SPACING IN THE SHADED AREA OF THE BEAM WITHOUT SHALL BE 2x THE PENETRATIONS IN THIS AREA DO NOT PRIOR APPROVAL OF THE ENGINEER DIAMETER LARGER HOLE THE REQUIRE APPROVAL FROM THE ENGINEER DEPTH DEPTH % DEPTH O DEPTH SPAN SPAN SPAN BEAM PENETRATIONS, TYPICAL DETAIL N.T.S. SPAN ROOF DIAPHRAGM PER STRUCT NOTES ���1 EDGE NAILS P SOLID `vSS� rlBLKG V I � EXISTING #H2.5A JOISTS MIN @ ALL ROOF EXISTING J�AVWALL MEMBERS JOISTS _L U.N.C. @ SHEARWALLS SHEARWALL w/ TRUSS OR RAFTER BEARING SWkI SHEARWALL ROOF CONNECTIONS #LS50 @ SHEARWALLS PER SCHED #H1 @ SHEARWALLS EXISTING JOISTS a b #H2.5A @ ALL ROOF MEMBERS N.T.S. SWRA DIAPHRAGM PER STRUCT NOTES FLR RIM/BLKG (OR ROOF GABLE) EDGE NAILS PROVIDE BLKG @ 48"oc w/ JOIST -WALL PARALLEL EXTERIOR SHEARWALLS SWF I SHEARWALL FLOOR CONNECTIONS N.T.S. SWFA WALL ANCH PER SW SCHED 2x SILL U,N.O. PER SW SCHED FDN SHEARWALLS TO FOUNDATION SWB SHEARWALL BASE PLATE &FOUNDATION CONNECTIONS N.T.S. EXTENT OF SHEARWALL SWBA EXTENT OF ",""I r ,m SHEARWALL m- ,", r T " "I A— TPS SWF SWR AT -;IL 1-11AVIA fLIYLIIVIIlVIY '.I�lrrLL JI VV L)MJL rLMIL OR HOLE THAT CAN BE ADDED TO A SHEARWALL SWE SHEARWALL ELEVATION N.T.S. SSS Number: s1904025 Project Name: Eslinger - 631 Elm St Owner: Mike & Colleen Eslinger Project Location: 631 Elm Street Edmonds, WA 98020 Design Professional: Michel Design M O V1 O H 0 J Q to L() dJ W z O V N � Ln u7 p z Ln O U p1 C V) Ln V) O V H Z 40421. fiGIs-��°�� Sf�NAL'�' tt' This space reserved for governing jurisdiction stamps ORIGIN DATE: 5/6/2019 REVISED: 3/12/2020 2 GR BEAM FnnTTMr;c I REINF MATCH HORIZ STD 900 HOOK INTO REINF INTERSECTING GR BEAM 1�-6CORNER BAR @ ALL OUTER REINF • REINF • 1 WALLS STD 900 HOOK INT MATCH HORIZ INTERSECTING GR BEAM REINF ALTERNATE EA BAR V-6" CORNER BAR @ ALL OUTER REINF'—' REINFORCEMENT AT INTERSECTIONS N.T.S. RIAA EXISTING FDN NEW FDN (2) #4x16" BARS 4" EPDXY EMBED •d YA4 NEW FDN IS CUT AWAY HERE TO HELP ILLUSTRATE THE CONN OF THE NEW REINF TO THE EXISTING FDN NEW TO EXISTING FOUNDATION N.T.S. #4 CONT whin TOP 12" OF WALL - 6" MIN FINISH GR 18" MIN CONC FTG AND REINF 3" CLR I i— BRG SOIL, ' SLAB NOTE: DEEPEN FOUNDATION AS REQUIRED TO ACCOMODATE FOR HOLDOWN EMBEDMENTS TEF I THICKEN EDGE FOOTING N.T.S. TEFA s NEFB kJ> EXISTING CONDITIONS STRUCTURAL MEMBERS AND ASSEMBLIES SHALL BE AS SPECIFIED ON PLANS. EXISTING CONSTRUCTION IS ADEQUATE WHERE IT MATCHES THE MATERIAL GRADES AND SPECIFICATIONS INDICATED ON PLAN AND GENERAL NOTES. WHERE EXISTING CONDITION OR PROPOSED CONSTRUCTION DIFFERS EITHER CONSTRUCT AS SHOWN ON PLANS OR CONTACT THIS OFFICE TO DISCUSS OPTIONS. WALLLINE WALL WALL LINE LINE A B C TCHED AREA REPRESENTS [STING FOUNDATION FOUNDATION PLAN 1/4" = V-0° DO NOT SCALE - VERIFY ALL DIMENSIONS WITH ARCHITECTURAL SHEETS PRIOR TO CONSTRUCTION SSS Number: s1904025 Project Name: Eslinger - 631 Elm St Owner: Mike & Colleen Eslinger Project Location: 631 Elm Street Edmonds, WA 98020 Design Professional: Michel Design M O V1 O H 0 J Q to Ln N J � � z F= O Ln u7 p z Ui s� 0 U p1 C O) V) Ln �V) X O OV H r_ p �p 44421. q �+ Sf0IVAL This space reserved for governing jurisdiction stamps ORIGIN DATE: 5/6/2019 REVISED: 3/12/2020 S3 PJ> WALL 7 WALL 7 WALL 7 WALL 7 WALL LINE LINE LINE LINE LINE A B V A B BASEMENT FLOOR AND FRAMING ABOVE 1/4" = V-0" kJ> EXISTING CONDITIONS STRUCTURAL MEMBERS AND ASSEMBLIES SHALL BE AS SPECIFIED ON PLANS. EXISTING CONSTRUCTION IS ADEQUATE WHERE IT MATCHES THE MATERIAL GRADES AND SPECIFICATIONS INDICATED ON PLAN AND GENERAL NOTES. WHERE EXISTING CONDITION OR PROPOSED CONSTRUCTION DIFFERS EITHER CONSTRUCT AS SHOWN ON PLANS OR CONTACT THIS OFFICE TO DISCUSS OPTIONS. DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS v 0 17, _ PF HDR �I �I 1 v I �I _ �I PF HDR F_ L #LTS12 TOP PLATE TO BLKG BTWN STUDS I� 0 I� 0 k' Ij r B6 SYMBOL LEGEND SLEXP ------------------- DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM. DIAPHRAGM PROJECTION Represents elements such as roof eaves, facades, and the like. SHEARWALL Represents walls which are shearwalls and shows the extents of that wall. Connections per the SHEARWALL SCHEDULE. #HOLDOWN MODEL HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE. POST Indicates the location of a post within walls below framing. Sizes are indicated on the plan. Grades are indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BHS for posts not indicated on the plans. INTERIOR BEARING WALL Indicates interior walls which support repetitive members. Construct per WALL FRAMING & BEARING in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 2-2x6 (or 4x6) U.N.O. on the plan. -JIL_ u HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL STRUCTURAL NOTES for the minimum size hanger. If a different model no. is required, it will be noted on the plan. JOIST, TRUSS, OR RAFTER Repetitive member symbol points in the direction of the span. The type, size and max spacing between members will be indicated in bold type with a symbol which is representative of the layout of the entire level. OVERFRAMING / Hatched area represents Overframing. See Structural Notes. SW A6 SOLAR -READY ROOF DEAD LOAD 20 PSF MAX LIVE LOAD 0 PSF MAX SNOW LOAD 25 PSF MAX SHEATHING OVER SHIPLAP 2-2x8 HDR (1-3) WALL LINE V �o �o z o ,�r I x N o SOLAR -READY ROOF N DEAD LOAD 20 PSF MAX u c LIVE LOAD 0 PSF MAX LU Cn SNOW LOAD 25 PSF MAX d H C7 SHEATHING OVER SHIPLAP — — #LTS12 TOP PLATE TO SW BLKG BTWN STUDS B6 0 �I VERIFY EXISTING DIAPHRAGM SHEATHING PER STRUCTURAL NOTES SHEATHING OVER SHIPLAP T X'x T / ' 7-7 lo HAR/ )i/ // // /D 1;2j/ 1st FLOOR SHEARWALLS & FRAMING ABOVE 1/4" = V-0" / / / / HATCHED AREA REPRESENTS OVERFRAMING DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS SSS Number: s1904025 Project Name: Eslinger - 631 Elm St Owner: Mike & Colleen Eslinger Project Location: 631 Elm Street Edmonds, WA 98020 Design Professional: Michel Design M O V O H 0 J Q to L() Lr) N z O L� N c/] " cn V) p z Ui uJ O U p1 C 4) V) Ln V) O H ti Q � z �p 44421. q �+ Is3 Sf0IVAL This space reserved for governing jurisdiction stamps ORIGIN DATE: 5/6/2019 REVISED: 3/12/2020 S4